Loading...
HomeMy WebLinkAbout2612 LA COSTA AVE; ; CB032838; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 t?~ 11-18-2003 Residential Permit Permit No: CB032838 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2612 LA COSTA AV CBAD RESDNTL Sub Type: Lot#: 2162800200 $0.00 Construction Type: Reference #: O Structure Type: 0 Bathrooms: MCMULLEN RES-PHOTO VOLTAIC SYSTEM-ROOF MOUNTED RAD 0 NEW 0 Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Orig PC#: Plan Check#: Applicant: Owner: KETCH ENERGY INC STE E 40935 COUNTRY CENTER 92591 909 719-3138 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee $0.00 $0.00 $0.00 $0.00 $0.00 $1.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 MCMULLEN FAMILY TRUST 12-04-02 2612 LA COSTA AVE CARLSBAD CA 92009 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFO Payoff Fee PFF PFF (CFO Fund) License Tax License Tax (CFO Fund) Traffic Impact Fee Traffic Impact (CFD Fund) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnLieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees TOTAL PERMIT FEES ISSUED 10/14/2003 RMA 11/18/2003 11/18/2003 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $119.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $120.00 Total Fees: $120.00 Total Payments To Date: $0.00 Balance Due: $120.00 Inspector: fbj) j FINAL APPROVAL Date· / 2, 'J -O' 3 8957 11/18/03 0002 01 CGP Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or seivice fees in connection with this project. NOR DOES IT APPLY to any x i n fwhi r vi I b Tl w i h u fl' i n h vi u I h rwi 02 FOR OFFICE USE O~ Y PLAN CHECK NO. C/i(B.QJJ ff PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 EST. VAL. __________ _ Plan Ck. Deposit ~ Validated B1 2_ Date /(3//9 L ~ I 1. PROJECT INF~ATIOJI ·2= G: I :L L-ofr ,q Address (include Bldg/Suite #) Business Name (at this address) Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units Assessor's Parcel # Existing Use Proposed Use ~cription of Work_ . SO. FT. #of Stories ;, 0 LA-/1..-(::; (....EC,....,,..rJ..1 e-f'1.157<.fl""1 ~ OF-MQ,Vr-J-TGJ) 2. CONTACT PERSON (If different from'ippllcent) # of Bedrooms # of Bathrooms Name Address City ~ntractor ~ent for Contraotor O Owner O Agent for Owner State/Zip Telephone # Fax # 3. APPLICANT k\.'.=Tc..H Name EA!t;;.At&--t --;r;,.J c. ~.112r a"'"'IM Gvt,,_ ti£ (Gelf<Jt<tt ~ -r Address r City State/Zip 26t-z..-LA-4ir-m--'4:ve Name Address City Ctr State/Zip 5. CONTRACTOR . COMPANY NAME (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exem tion. Any violation of Section 7031.5 by any applicant for a permit subject the applicant to a civil penalty of not more than five hundred dollars [$5001). . ---= L--UJ\}.,•.ru: N 71-:ti:--G. 1 -'t I Name State License # ('7 l 6 ' J AvVl.6 Designer Name State License # _________ _ 6. WORKERS' COMPENSATION Address City Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: State/Zip Telephone 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ~ have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy n ~ are: /I (} A7 ,t? / j Insurance Company -(Sd l(J WI Policy No. lta '1 JLD ' I l Expiration Date / I () 'f: t I (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to s cure work rs' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($ , 00), i d' Ion to the cost of compensation, damages as provided for in Section 3706 of the ~abor c de, lnte est and attorney's fees. SIGNATURE ~ DATE f Q / ---'--='-f-'---L'-.,._.'---,L. 7. OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). O I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address I phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number): ______________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address / phone number / type of work): ________________________________________________________ _ PROPERTY OWNER SIGNATURE _______________________ _ DATE _________ _ COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES O NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site 7 0 YES O NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME ______________ _ LENDER'S ADDRESS ________________________ _ 9. APPLICANT CERTIFICATION I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST All LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is comm e · O days (Section 106.4.4 Uniform Building Code). / :1 APPLICANT'S SIGNATURE ---,,_5,,""c....;..--f-{--;,Q«\,4,-"<;::'--------------DATE ( O/(L11 _{) ?- WHITE: File YELLOW: Applicant PINK: Finance City of Carlsbad Bldg Inspection Request For: 12/02/2003 Permit# CB032838 Title: MCMULLEN RES-PHOTO VOLTAIC Description: SYSTEM-ROOF MOUNTED Type: RESDNTL Sub Type: RAD Job Address: 2612 LA COSTA AV Suite: Lot 0 Location: APPLICANT KETCH ENERGY INC Owner: MCMULLEN FAMILY TRUST 12-04-02 Remarks: PHOTOVOTAIC SYSTEM Total Time: Act Comment Inspector Assignment: RB --- Phone: 9095432109 Inspector: ---- Requested By: TOM Entered By: ROBIN CD Description 39 Final Electrical p ____ _ Associated PCRs/CVs Inspection History Date Description 11/20/2003 28 Solar, Domestic Hot Water 11/20/2003 33 Service Change/Upgrade Act lnsp Comments WC RB CO RB NEED CONTRACTOR ON SITE DATE: November 14, 2003 JURISDICTION: Carlsbad PLAN CHECK NO.: 03-2838 : EsGil Corporation In (Partners nip witn qovemment for rBui(aing Safety SET:111 PROJECT ADDRESS: 2612 La Costa Ave. · ANT EVIEWER □ FILE PROJECT NAME: Solar system roof mounted McMullen Residence ■ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ■ Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax#: Mail Telephone Fax In Person □ REMARKS: By: Bryan Zuppiger Enclosures: Esgil Corporation D GA D MB D EJ D PC LOG trnsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 DATE: November 10, 2003 JURISDICTION: Carlsbad PLAN CHECK NO.: 03-2838 EsGil Corporation - In <Partnersnip witn (]ofJernmentfor(BuififinlJ Safety SET: II PROJECT ADDRESS: 2612 La Costa Ave. □ ~!§ANT □ RI □ PLAN REVIEWER □ FILE PROJECT NAME: Solar system roof mounted McMullen Residence D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [gl The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [gl The applicant's copy of the check list has been sent to: Ketch Energey Inc. 40935 County Center#E Temecula CA 92591 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. [gl Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: 1cic-ro-t ENc:ILC.'-/ Telephone#: (909) 719-3138 Date contacted: l t I ,o ( o ~ (by: f?----) ( '1 · 1-1~ Fax #: Mail'--"'relephone ✓ Fax In Person 0 REMARKS: By: Bryan Zuppiger Esgil Corporation 0 GA O MB O EJ O PC Enclosures: 11/03/03 trnsm~.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad 03-2838 November 10, 2003 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2612 La Costa Ave. DATE PLAN RECEIVED BY ESGIL CORPORATION: 11/03/03 REVIEWED BY: Bryan Zuppiger FOREWORD (PLEASE READ): PLAN CHECK NO.: 03-2838 SET: II DATE RECHECK COMPLETED: November 10, 2003 This plan review is limited to the technical requirements contained in the Uniform Building Code,- Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new sets of prints to: ESGIL CORPORATION. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? □Yes □No Carlsbad 03-2838 November 10, 2003 ♦ ELECTRICAL PLAN REVIEW ♦ 1999 NEC 1. The 20 ampere 240 volt de fuse is oversized for the 4.8 amps from the array. NEC 240-6 There was no response to this item. 3. The licensed designer must sign the approved set of the plans. Signature required on final set. Note: The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bryan Zuppiger at Esgil Corporation. Thank you. DATE: 10/22/03 JURISDICTION: Carlsbad PLAN CHECK NO.: 03-2838 EsGil Corporation In <Partnersfiip witfi qo,.ernment for <Bui(aing Safety SET:I PROJECT ADDRESS: 2612 La Costa Ave.·· □ APPLICANT ~ □ PLAN REVIEWER □ FILE PROJECT NAME: Solar system roof mounted (1---1ct--1uLL6rJ f'f:S1pE-,JCt:) D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Ketch Energey Inc. 40935 County Center #E Temecula CA 92591 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. ~ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: fo/i..Y0.!, (by: /C-) Mail Telephone Fax In Person 0 REMARKS: By: Morteza Beheshti Esgil Corporation D GA D MB D EJ D PC Telephone#: (909) 719-3138 Fax#: ('1o°J) +19.3123 Enclosures: 10/16 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad 03-2838 10/22/03 GENERAL FILAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: 2612 La Costa Ave. DATE PLAN RECEIVED BY ESGIL CORPORATION: 10/16 REVIEWED BY: Morteza Beheshti FOREWORD (F!LEASE READ): PLAN CHECK NO.: 03-2838 DATE REVIEW COMPLETED: 10/22/03 This plan review is limited to the technical requirements contained in the Uniform-Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections on the original tracings and submit two new complete sets of prints to: ESGIL CORPORATION. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? 0 Yes D No Carlsbad 03-2838 10/22/03 ♦ ELECTRICAL PLAN REVIEW ♦ 1999 NEC 1. The 20 ampere 240 volt de fuse is oversized for the 4.8 amps from the array. NEC 240- 6 2. Please specify the ac side wire and conduit sizes. NEC 240-3, 690-31 3. The licensed designer must sign the approved set of the plans. Note: The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Morteza Beheshti at Esgil Corporation. Thank you. Carlsbad 03-2838 10/22/03 !VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.:. 03-2838 PREPARED BY: Morteza Beheshti BUILDING ADDRESS: 2612 La Costa Ave. DATE: 10/22/03 BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING AREA Valuation Reg. VALUE PORTION ( Sq. Ft.) Multiplier Mod. Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance 1994 UBC Buildin g Permit Fee ..... --~-.-----~. 1994 UBC Plan Check Fee Type of Review: D Complete Review 0 Structural Only 0 Repetitive Fee . [_~_ .;.-J Repeats 0 Other 0 Hourly 21 Hours• Esgll Plan Review Fee * Based on hourly rate Comments: Electrical Plan Review. ($) . $240.ooj $192.001 Sheet 1 of 1 macvalue.doc PLANNINC/ENCINEERINC APPROVALS PERMIT NUMBER caO 3, )fj 1f DATE /U-/)-6) ADDRESs~/l_b...;...._.(,:._/_____;.~~~/4-'-'-''---~-·-~---- RESIDENTIAL ADDITION MINOR ( < $10,000.00) DoCSIMlliifonnsJPtanning Englnftfing AppravaLs TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING DATE DATE / c/;6(0 - {