Loading...
HomeMy WebLinkAbout2614 PIRINEOS WAY; ; CB020414; Permit5'Th1 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 03-04-2002 Retaining Wall Permit Permit No: CB020414 Building Inspection Request Line (760) 602-2725 Jôb Address: 2614 PIRINEOS WY CBAD Permit Type: RETAIN Status: ISSUED JParcel No: Lot #: 0 Applied: 02/08/2002 'Valuation: $19,845.00 Construction Type: NEW Entered By: RMA 'Reference #: Plan Approved: 03/04/2002 Issued: 03/04/2002 'Project Title: PIRINEOS POINTE-BLDG 1-1260 SF Inspect Area: KEYSTONE WALL ,AppIicant: Owner: . DARRYLCLUBB 2174 03/04/02 0002 01 02 .7 CGP 29352 858 689-8911 Total Fees $293.52 Total Payments To Date $0.00 r ( Balance Due $293.52 Building Permit $176.69 Add 'I Building Permit Fee 7 $0 00 Plan Check .; " $114.85 Add 'I Plan Check Fee .' $0.00 Strong Motion Fee $1 98 '":" Renewal Fee - .• .. - / $0.00 AddI Renewal Fee • . $0.00 Other Building Fee ".. I - • $0.00 Additional Fees - $0.00 TOTAL PERMIT FEES ' / iJ / ( $293.52 \ -I' J•• •••\•\ ... ••. - I 21 e / / FINAL APPROVAL Inspector: ' £$'1"— (,,,t)Date: (('_ Clearance: NOTICE: Please take NOTICE that approval of your çect includes the "Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions.' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given p NOTICE similar to this. cr as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION CITY OF CARLSBAD BUILDI NG D 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO. EST. VAL. I?) Plan Ck. Deposit Validated By_________________________ Date R..iioRMA1IpN . .. Address (include Bldg/Suite #1 Busines-'Jame (at this address) W4y ez-,D& 461 Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units 47g- / Assessor's Prcel # Existing Use Proposed Use 2-o0 Descripti n of Work SQ. FT. #of Stories # of Bedrooms # of Bathrooms 2 CONTACT PERSON lit different from applicant) -ziz- Name Address -. City - State/Zip ' Telephone # Fax # rContracthr . -.. - . .. .. .... 5'. Name Address City State/Zip Telephone # Name Address City. State/Zip Telephone # .5. CONTRACT.OR-CCM.,NY,N..M . . . . (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exe tion. Any violatio of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($ 5001). &7,57 7/ %i '1-r2-u7 or 6 Name Address City State/Zip Telephone # State .,License # 0-72' 3 7 License Class .3 City Business License # Designer Name Address City ' State/Zip Telephone State License # 6 WÔRKEFtS COIPENSATION , . Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is /issued. My worker's compensation insurance carrier and policy number are: 'i,i2 . Policy No. Expiration Date_________________ Insurance Company , (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS) o . CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil finei up to one hundred thousand dollars ($100,000), in addition to th cost f co en I n, damages as provided for in Section 3706 of the Labor code, terest and attorney's fees. SIGNATURE 'FT7:I:4-& DATE 2---- '-c Z_- 7" OWNER UILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of.completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section ______________ Business and Professions Code for this reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO I (have / have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name / address I phone number / contractors license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone number I contractors license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number I type of work): PROPERTY OWNER SIGNATURE ___________________________ DATE COMP,LETE THIS SECTION FOR NONRESIDENTIAL BUILDING -00 '.,g Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8 CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction endirig age cy for the performance of the work for v.,hi, i this pLrrnit is issued (Sec. 30970) Civil Code). LENDER'S NAME YA//* t?)4 d 4ENDER'S ADDRESS 'Q T. i, c'1 .'. ....... ..::............................- 5'. ............S '.5 I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit, of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not co~c e ed within 180 days from the da,)9 of such permit or if e building or work authorized by such permit is suspended or abandoned at any time after the work is ir a nerio of 180 days (SeWn 106)'4 U form j)dng Code). APPLICANT'S SIGNATURE - 4'f f/ -DATE 2--- —' 7-- W E. F le YELLOW. Applicant PINK. Finance City of Carlsbad Bldg Inspection Request For: 01/31/2003 Perrnit# CB020414 Inspector Assignment: RB Title: PIRINEOS POINTE-BLDG 1-1260 SF Description: KEYSTONE WALL Type: RETAIN Sub Type: Phone: Job Address: 2614 PIRINEOS WY Suite: Lot 0 Location: Inspector: APPLICANT DARRYL CLUBB Owner: Remarks: Total Time: Requested By: CHRISTINE Entered By: CHRISTINE CD Description Act Comment 69 Final Masonry ifr 4y as Lai) oi , fr ? Associated PCRs/CVs Inspection History / ,qf( l,4r a-& o--i r , Date Description Act Irisp Comments 09/10/2002 63 Walls CO RB SEE NOTICE ATTACKED 09/10/2002 66 Grout CO RB 07/12/2002 11 Ftg/FoundationlPiers CA RB WRONG JOB CALLED IN 05/07/2002 61 Footing NR RC IN FOR PCR 03/21/2002 61 Footing AP RC SPECIAL INSP REPORT FILED ROM. :TOM RICE I + FAX NO. :7609441744 Mar. 20 202 0:04p P1. P-1 BARRY AND ASSOCIATES GEOTECINlGAL ENGINEERING P.O. Box 230348 Endnitas, CA 92023-0348 (760) 753-9940 March 20, 2002 Darryl C.ubb Coast Contracting 7929 Silverton Avenues Suite 609 San Diego, California 92126 Attfl Mr. Tom Rice Subi cot: KEYSTONE RETAINING WALl. FOOTING INSPECTION PIRINOS OIN'rE PIRINEOS WAY CARLSMP, CALIFORNIA Reference: Grading Plan Prepared by Engineering Design Oroup Dear Mr. C1Ubb in response to your request, we have inspected the excavation in preparation for the Keystone retaining at the subject site. The bottom of the footing excavation was inspect on )arch 20, 2002, The bottora of the footing excavation was probed with a steel probe and deLermined to be adequate for the proposed retaining wall. The depth and width of the footing excavation are In accordance with the approved plan and the Keystone calculation sheets for the referenced site. It you have aity questioAA , plea;e contact as at 760.753 9940. Respectfully submitted, A.R. BARRY ASSOCATES Principa.L Enin,4r copy. Inepectoj, City of 14 01019 E40.3/31104 t,. Cit of 'Carlsbad BUILDING PLANCHECK CHECKLIST RETAINING WALL BUILDING PLANCHECK NUMBER: CBO cjg BUILDING ADDRESS: (1,1L C"€oS PROJECT DESCRIPTION: Retaining Wall ASSESSOR'S PARCEL NUMBER: /(p2-e2c ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has -been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore, any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result inension of permit to build. BV7'4 t4d Date: DENIAL Please see the attached report of deficiencies marked with 0. Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/orspscifications to-this office for review. - - By: Date: By: Date: By: Date: ATTACHMENTS ENGINEERING DEPT. CONTACT PERSON 11 Right-of-Way Permit Application NAME: TAN IYA WADE City of Carlsbad ADDRESS: 1635 Faraday Avenue Carlsbad, CA 92008 PHONE: (760) 602-2773 u\W,,Pflnnrc\rJKt snpejaining WA Rk4ng Ptn.fl.+ (kk Fn II 1n. P R!AR 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-2720 • FAX (760) 602-8562 3RDI c P 7: U BUILDING PLANCHECK CHECKLIST RETAINING WALLS 1. Provide a fully dimensioned site plan drawn to scale. Show: North Arrow D. Easements Existing & Proposed Structures E. Retaining Wall (dimensioned from street) (location and height) Property Lines Show on site plan: A. Drainage Patterns B.. Existing & Proposed Slopes C. Existing Topography 3. Include On title sheet: Site Address Assessor's Parcel Number . Legal Description Grading Quantities Cut . Fill Import/Export (Grading Permit and Haul Route Permit may be required) 0 0 4. Project does not comply with the following Engineering Conditions of approval for Project No. Conditions were complied with by: Date: MISCELLANEOUS PERMITS 0 0 0 . 5. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. A separate Right-of-Way issued by the Engineering Department is required for the following: .. . Please obtain an application for Right-of-Way permit from the Engineering Department. Page 1 Wall 8ulI19 Plevthedc C*s* Fonfl DR 40C Rev. 8,26196 PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CBO 2, _71'JJ Address?/'/ /--' Planner /2 Phone (760) 602- APN: o2// j Type of Project & Use:--,_ Density:-1(- DU/AC Zoning: _'D-,11 General Plan: _iEE /1' Facilities Management Zone: CFD (in/out) #/V/9 Date of participation: Remaining net dev acres:______ Circle One (For non-residential development: Type of land used created by this permit: ) Legend: Item Complete Item Incomplete - Needs your action Environmental Review Required: 'NO YES TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES NO TYPE APPROVAL/RESO. NO. DATE PROJECT NO. SDP oo -/( OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: E Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES NO____ CA Coastal Commission Authority? YES NO____ If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES NO If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Follow-Up Actions: H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 l Inclusionary Housing Fee required: YES NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES NO (AJP/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing YIN, Enter Fee, UPDATE!) Site Plan: Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing Street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. Zoning: El' 1. Setbacks: Front: . Required . Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Top of slope: Required Shown LITh 2. Accessory structure setbacks: Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Structure separation: Required Shown E1 3. Lot Coverage: Required Shown E 4. Height: Required Shown F~ FIR 5. Parking: Spaces Required Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown EEI"LII Additional Comments___________________________________________________ OK TO. ISSUE AND ENT RED APPROVAL INTO COMPUTER DATE . . . H:'ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 City of Carlsbad 1635 Faraday Av Carlsbad, ëA 92008 05-13-2002 Plan Check Revision Permit No: PCR02086 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: Project Title: Applicant: DARRYL CLUBB 2614 PIRINEOS WY CBAD PCR Lot #: 0 $0.00 Construction Type: NEW PIRINEOS POINTE-CHANGE FROM KEYSTONE TO °A-16" RETAIN WALL SYSTEM Owner: Status: ISSUED Applied: 03/21/2002 Entered By: RMA Plan Approved: 05/13/2002 Issued: 05/13/2002 Inspect 05/13/02 0002 01 02 COP .12O00 858 689-8911 Total Fees: $120.00 Total Payments To Date: $0.00 Balance Due: $120.00 Plan Check Revision Fee . $120.00 Additional Fees $0.00 F 4 FINAL APPROVAL Inspector: Date: Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given p NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. 'II '.1 / PERMIT APPLICATION PLAN CHECK NO Cl OF CARLSBAD BUILD PARTMENT I FOR OFFICE USE 0 LV EST. VAL. __________ 1635 Faraday Ave., Carlsbad, CA 92008 Plan Ck. Deposit - I Validated B',- ii k" ousiness name tax mis aooressi Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. Total # of Assessor's Parcel # Existing Use Proposed Use (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001). Name Address City State/Zip Telephone # State License # License Class City Business License # Designer Name Address City State/Zip Telephone State License # 6 WORKERS COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No._____ Expiration Date__________________ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE-HUNDRED DOLLARS ($1001 OR LESS) CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' cDmpensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE DATE 7 OWNER-BUILDER DECLARATION . I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law. I am exempt under Section Business and Professions Code for this reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES DNO I (have / have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number I type of work): PROPERTY OWNER SIGNATURE DATE OMPt'ETE THIS %ECTION FOR NON-RESiDENTiAL BU'iLDINô PERMITS ONLV Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT. HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. i'ONSTRUC11ON LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS__________________________________________________________ 9 APPLICANT CERTIFICATION 'S I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit' of Carlsbad to enter upon the above mentioned property for, inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 50" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date oj4lich permit or J,the bildg or work authorized by such permit is suspended or abandoned at any time after the work is ca.iei'4jor a pjgd-ef-+€Q days (Section A6.4.4 ~JoornjAuilqofiAde). APPLICANT'S SIGNATURE 'z-c--i A '1d 3 --z---- WHITETle (YELLOW: Applicant PINK: Finance (I - EsGil Corporation 112 1'rtws#Up Wita gavernmentfQr Wui(ing safety DATE: March 21, 2002 JURISDICTION: Carlsbad PLAN CHECK NO.: 02.414 PROJECT ADDRESS: 2614 Pirineos Way SET: I D APPLICANT JURIS. PLAN REVIEWER, FILE PROJECT NAME: Revision for Keystone Rot/wall to A-16 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies Identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. Q The check list transmitted herewith is for your Information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. O The applicant's copy of the check list Is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mall Telephone Fax In Person REMARKS: Plans handcarrled by Darryl Club By: Bert Domingo Enclosures: Esgil Corporation OGA 0MB DEJ [I PC Log - trnern.dot 9320 Chesapeake Drive, SuIte 208 • San Diego, Califbrnia 92123 • (858) 560-1468 • Fax(858)560-1576 Od ii ZOOZ i-w 9LST09S8S8T:xJ diOJ 1I9S3 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 02•414 PREPARED BY; Bert Domingo DATE; March 21, 2002 BUILDING ADDRESS: 2614 Firineos Way BUILDING OCCUPANCY: TYPE OF CONSTRUCTION; 1J1EDING - ARA lFValuation - Reg. VAUJE ($) PORTION (Sq. _FMultipDer Mod. Air Condftioning Fire Sprinklers TOTAL VALUE Jurtsdiccn Code Cb IDY Ordinance !do.PemOt Fee by0nance TW7 -Il Plan 0ek Fee by ordnance IVI $120.001 Type of Review; Complete Review 0 Structural Only DReP8Ve Fee EE] Repeats 'Baaed on haurly rate Comments: D Other [21 Hourly • lJHour" E5g11 Plan Review Fee 1- 296.001 Sheet 1 of I mcvaIue.doc S0d 91:91 OO TZ JW 9LST09S8S81xJ dOJ 110S3 lTCo'rporatlon In arnersNp rsPtt govtrnmentfr uf!dbig..cafty FAX TRANSMITTAL Date: - J! 10 - Number of Pages Being Transmitted: 3 (Including Fax Transmittal) Time Sent: To: CA3bAt - From - Phone #: Hard Copy Mailed? YES NO Fax #: -C-4C.0) CoW . k6Sr Remarks: - 9320 Chesapeake Drive, Suiw 208 • Saii Diego, Califoniia 92123 • (858) 560-1468 • Fax (858) 560-1576 TO 'd t:9ZOO TZ JN 96T0988Tej dOD 1I9S ft PLANNING/ENGINEERING APPROVALS PERMIT NUMBER(CB' O- — // / " DATE t~~~q /0 ______________ ADDRESS k) RESIDENTIAL TENANT -IMPROVEMENT RESIDENTIAL ADDITION MINOR PLAZA CAMINO REAL (<$10,000.00) CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER -. PLANNER DATE ENGINEER DATE DocsiMisforms/planning Engineering Approvals V. EARTH RETENTION CAL CULA TIONS FFEBRUARY 8,2002 SHEET 1 O 6( PREPARED BY: RETAINING WALLS COMPANY NORTH 1800 THIBIDO DRIVE SUITE 110 VISTA, CA 92083 (760) 599-2500 PROJECT CONTACT: PAUL WINTER RWCN CLIENT: COAST CONTRACTING. 7909 SILVERTON AVENUE, SUITE 213 SAN DIEGO, CA 92126 (858)689-8911 SITE: PIRINEOS POINTE CAR SBAD PIRINEOS WAY (APN 216-200-2400) CARLSBAD, CA SOIL DATA FROM: ENGINEERING DESIGNGROUP 2121 MONTIEL ROAD SAN MARCOS, CA 92069 (760) 839-7302 LETTER DATED: NOVEMBER 20, 2001 PROJECT NUMBER: 002425-1 wl NO. C22091)6 '- Exp. Date 9/3 CIVIL 'CAL **************************************************** aSE NOTE: THESE STRUCTURAL CALCULATIONS ARE ONLY VALID F(1 -RETAINING WALLS COMPANY NORTH. IT IS REQUIRED AS A CONDITION )F-T SVCTURAL CALCULATIONS, THAT A MEMBER OF THE RETAINING WALLS COMPáTH STAFF, FIELD APPROVE THE CONSTRUCTION OF THIS PROJECT. RETAININWALLS ç1ANY NORTH WILL NOT ACCEPT RESPONSIBILITY FOR ANY PROJECT RELA?) $HOUT WRITTEN FINAL APPROVAL FROM RETAINING WALLS COMPANY NO • Em JOBNO. CONTENTS A-16 RETAINING WALL SITE LOCATION A-16 RETAINING WALL TYPICAL SECTIONS A-16 CONCRETE BLOCK DETAIL GENERAL NOTES AND SPECIFICATIONS GEOGRID REINFORCEMENT TABLE STABILITY ANALYSIS - (3:1 Sloped Backfill) PAGE 3 4 5. 6 7 8-61 NOTES: THESE CALCULATIONS ARE BASED UPON A SOIL WITH INTERNAL FRICTION OF 30 DEGREES MINIMUM. THE SOILS, ENGINEER SHALL VERIFY THESE SOIL PARAMETERS DURING CONSTRUCTION THE SOILS ENGINEER SHALL OBSERVE THE TEMPORARY BACKCUT EXCAVATION PRIOR TO CONSTRUCTION. . S THE SOILS ENGINEER SHALL OBSERVE ALL WALL DRAINS. THE SOILS ENGINEER SHALL OBSERVE THE FOUNDATION EXCAVATION PRIOR TO CONSTRUCTION OF THE WALL. THE SOILS ENGINEER MUST NOTIFY THE DESIGN ENGINEER IN THE EVENT THAT THE SOIL CONDITIONS ENCOUNTERED DO NOT MEET THE PARAMETERS USED HEREIN THE GRID LENGHTS SHOW ARE MEASURED FROM THE WALL FACE THE GRID ELEVATIONS ARE MEASURED FROM THE TOP THE LEVELING PAD. NO LAYER OF GEOGRID SOIL REINFORCEMENT SHALL BE PLACED WITHIN THE UPPER MOST 2 FEET OF THE WALL. . .. HEAVY EQUIPMENT SHOULD BE KEPT 3 FEET BACK FROM THE RETAINING WALL FACE AT ALL TIMES. 4th Ni, I I Aft - I PROPOSED 3;! MAX PROPOSED RETAINING WALL PROPOSED CONCRETE .64 7353 TW FILL SLOP 73.48. TIN T A 1NDER:sEeAATE PERMIT FLAIYIORK 55 p65.2 6 5 63.84 68.58 •70. TW 62 Bul G 6 63.5 '• A •(WA~L TW co 5, - .- LL:E Is RZ _.. - = :. - . . . 79.3 ~FS XISTING I0 SR ASEMENT DEDICATED PER 4P 6462 -- TYP EXISTING 8 V C SEWER M4IN 81 86PA M1I - PROPOSED 6 DIA SC?! 40 fl I PVC 2% MIll SLOPE TO 5 1p ci / / PROPOSED RETAINING WALL i BUt L D s -- BUt L. 0 6 2 Ii UNDER SEPARATE PERMIT r_ I OOTW 76 77FS -. 76 93FS 77 IOFS 7 T V6 .508W 37FS 7720F 77 3FS 4 8 / 60 V 60.091E 60.341E 13.1 ILI .• 77.37p$ 77.20F..---77.0SF - .. . ;•.-' r:ii 6 I I (4) PROPOSED 4 SEWER LATERALS PER M4D 58 Ui bD 4 79.6 VS 0 PAD 6 87 D 6 PA 75,-SO - I I '- -.— 18 IEF ( I PROPOSED 6 DIA SCM 40 2 76 20 / I PVC a 2Y MIN SLOPE To 2 4 PS 60FF OUTLET I .77 iDPAD " I BSPAD ,- II PØED 6 4 508 ,j UILJ 3 i FI D 2V MIN 81 60 75 71 Rf To &WPE TD.TJTLET I 0 6IFS 888P4& -- -— PROPOSED CONCRETE 77 6IFS - , TO - 60 6- 75 0 ' I QTJA1?L' 8?OQ 80 93 I - ) 86 S UF , 7ff P!P P r PROPOSED 18' R.C.P. STORM \ I 'DRAIN PIPE 0 0.5% MINIMUM . F •... . ..- SLOPE TO OUTLET SEE CITY . -. '-- ': • \ / - F . I • - jAI?LSRAD DRAWING No. 395-1 RECOMMENDED BROW DITCH BY OTHERS SECURE FIRST COURSE WITH EPDXY ADHESIVE A-16 BLOCK ~__GEOGRID (TYP) LENGTH, TYPE AND 3/4" CRUSHED ROCK ELEVATION PER TABLE WITHIN ALL UNITS 0 I - 0 I •. ' . , S 1 SETBACK_.I - - - I 6 MIN WIDTH OF 3/4 CRUSH ROCK (36" HIGH): : . . BURIAL PER SOILS ENGINEER - - - ' 4 PERFORATED PVC DRAIN IN FILTER FABRIC SLEEVE WITH SOLID OUTLET PIPES 'AT 10 MAXIMUM SPACING. LOCATE DRAIN AS. LOW: AS POSSIBLE TO MLOW OUTLET PIPE TO 'DAYLIGHT. •L...._6,THICK::X 2.' WIDE 3/4" ' , '.'• II CRUSHED ROCK LEVELING PAD *NOTE IF CAPSTONES ARE NOT TO BE USED THE TOP 'HALF OF 'THE UPPER ROW OF BLOCKS SHALL 'BE 'FILLED WITH HAND TAMPED SOIL. . •. A-16RETAINING WALL TYPICAL CROSS-SECT1ONT" WITH •GEOGRID- SOIL REINFORCEMENT NO SCALE SOUTHERN OFFICE RETAINING WALLS CO. N. NORTHERN OFFICE 1800 THIBODO RD. #110 ' . . ' ' ' ' •• - 1240 WEST 11TH St. VISTA, CA. 92083 ' . A-SERIES SEGMENTAL RETAINING WALL DETAIL , TRACY, 'CA. 95376 (760) 599-9595 ' S ' • , (209) 832-2600 p •. : FACE VIEW : 8" 4" 1 17 0" 4" - -1/2" SIDE VIEW TOP VIEW NOTES: 1. COMPRESSIVE STRENGTH OF CONCRETE f'c 3250 PSI A_16TM :RETAINING WALL UNIT DIMENSIONS NO SCALE SOUTHERN OFFICE RETAINING WALLS CO. N. NORTHERN OFFICE 1800 THIB000RD. #110 • • : • 1240 WEST 11TH St. VISTA, CA. 92083 A—SERIES SEGMENTAL RETAINING WALL DETAIL TRACY, CA. 95376 (760) 599-9595 DETAIL NO. A-16 • • (209) 832-2600 TECHNICAL SPECIFICATIONS FOR A—SERIES SEGMENTAL WALL SYSTEM 1.0 GENERAL Work shell consist of furnishing and installing Segmental Retaining Walls constructed in accordance with these specifications and in reasonably close conformity with the lines, grades, design and dimensions shown on the plans or established by the Engineer. . . 2.0 MATERIALS . 2.1 A—Series Facing Modules A. The facing modules shell be manufactured by a licensee of Retaining - Walls Company North. 1531 Grand Avenue, San Marcos, Co 92069. B. Facing modules shall hove a minimum compressive strength of . 3000 psi at 28 days. . . -2.2 Soil Reinforcement A. Soil Reinforcement shall be of either sheet or grid type, specifically fabricated for use as a sail reinforcement. B. Sail reinforcement shall be the type as shown on the drawings and/or design calculations. The Contractor, or the supplier as his agent, shall furnish the Engineer a Certificate of Compliance certifying that the soil reinforcement complies with this section of the specifications, the drawings and the design. calculations. Material not conforming to these shall not be used without the prior written consent of the Engineer. 2.3 Reinforced Soil Backfill All backfill materials used in the 'reinforced Soil volume shall be free from stones or lumps exceeding 3 inches in greatest dimension, organic material, or unsuitable material, as determined by the Engineer. ' Backfill materials used in the reinforced sail volume and backfill soils behind the reinforced soils volume shall have material properties similar to those indicated on the drawings or in the design calculations and shall conform to the requirements of the Sails Engineer. 3.0 CONSTRUCTION 3.1, A—Series Facing Modules , Excavation 1.0 Contractor shall excavate to the 'lines and grades shown on the site civil site drawings. Contractor shall be careful not to disturb embankment materigls 'beyond lines shown. Foundation Soil Preparation 1.0 Foundation soil shall be cut level for a width equal to or-exceeding the length of the soil reinforcement as shown on the construction drawings. or as directed by the Soils Engineer. 2.0 Foundation soil shall be examined by the Sails Engineer to assure' that the actual foundation soil strength meets or exceeds the asumed design strength. Soils not meeting required' strength shall be removed and ' replaced with acceptable material as determined by the Soils Engineer. 3.0 Over excavated areas shall be filled with, compacted backfill material as directed by the Sails Engineer. , Base Leveling Course 1.0 Leveling 'course shall be placed as shown on the construction drawings. 2.0 Leveling course materials shall be installed upon undisturbed sails or' recompacted fill as directed by the Soils Engineer. , ......'..... 3.0 Leveling course shall be prepared to insure complete contact of. segmental facing units with leveling course. . Segmental Facing Unit Installation 1.0 First course of concrete wall units shall be placed on the leveling course. The units shall be checked for level and alignment. 2.0 Insure that units are in full contact with leveling course. Rewsiow 7/10/95 fltE xsPc, 3.0 Units ore placed side by side for full, length of wall alignment. Alignment may be done by means of a string line or offset from base line. 4.0 Install Segmental facing units and fill wall units with 1/2' or 3/4' crushed rock. Place drainage material behind units as indicated on construction drawings...' 5.0 Sweep. oil excess material from top of units and install next course. Insure e0ch course is completely filled prior to proceeding to the next course. 6.0 Lay up each course maintaining design batter of wall face as shown on construction drawings. Repeat to ,extent of wall height. 7.0 At the, end of each course where the wall changes elevation, units shall be turned into the, backfill. A minimum of two units shall be installed into the grade. Only the front face of the units shall be visible from the side of the wall. , .3.2 Soil Reinforcement Installation The soil reinforcement shall be laid horizontally on compacted bock(ill and shall extend. to the face of the wall. Slack, in-the-soil reinforcement shall be removed between ,the facing units. Soil reinforcement shall be pulled to eliminate, slack prior to placing fill soils. Soil reinforcement shall be laid at the proper, elevation and orientation as shown on the construction drawings or as directed by the Engineer. Correct 'orientation (roll diiec(ion) of the soil reinforcement shall be verified by the Contractor. Sail reinforcement may be secured in place with staples, pins, sand bags, or backfill, or as directed by the Engineer. Adjacent borders of the soil reinforcement shall, be. butted 'together. No overlap is necessary. If overlap occurs the preceedin9 roll shall overlap the following rail in the direction that the fill material is being spread. C. There shall be no soil reinforcement joints parallel to the Wall face. The soil reinforcement must be continuous from face of wall to back of grid. 3.3 Backfill Placement A. Backfill shall be placed, spread, and compacted in such a manner that minimizes,the.'movement of the wall units and the development of wrinkles in and/or movement of the sail reinforcement. Any sail reinforcement material or facing, units 'which become domogçd during backfill placement shall be either removed, and replaced at the Contractor's expense or repaired as directed by the Engineer.' 'B.' Backfill material shall be placed in layers of uniform thickness and shall be compacted as 'specified in the project specifications or to a minimum of 90% of maximum density as determined by ASTM 01557-91, whichever is greater. C. Construction equipment shall not be operated directly on the soil reinforcement. A minimum backfill thickness of 6 inches is required prior to operation of equipment over the soil reinforcement. Turning of equipment shall be kept to a minimum to prevent displacement of the fill and damaging the soil reinforcement. Sheepsfaot or grid type rollers shall only be used as directed by the Engineer. ' 0: The moisture content of the backfill material prior to and during compaction shall be uniformly distributed throughtout each layer of material. Backfill material shall have a placement moisture content of +/— 2% of the Optimum Moisture Content. Backfill material with a placement moisture content 'outside of these limits shall be removed and reworked until the moisture content is uniformly acceptable throughout the entire lift.' The Optimum Moisture Content shall be deterrnln,ed -In accordance with ASTM 01557-91. The maximum .lilt thickness utter compaction shall not exceed 10 inches. The Contractor sf011 decrease this lift thickness. if necessary, to obtain the specified density. At the end of each day of operation when the chance of rain exists, the Contractor shall slope the last level of backfill away from the wall face to direct runoff 'of rainwater away from the wall face.' In addition, the Contractor shall not allow surface runoff from adjacent areas to enter the wall site. GEOGRIDRMNFORCEMENT TABLES LEVEL BACKFILL WALL HEIGHT GRID ELEVATION GRID LENGTH GRID TYPE up TO 2.67' no grid required. 3.33' TO 4.00' . 1.33 4.5 . SYMPAFORCE 35/20-20 4.67' TO 6.67' 1.33 6.5 SYMPAFORCE 35/20-20 4.00 6.5 SYMPAFORCE 35/20-20 7.33' TO 8.00' 0.67 . 7.5 SYMPAFORCE 35/20-20 2.67 7.5 SYMPAFORCE 35/20-20 5.33 7:5 SYMPAFORCE 35/20-20 8.67'. TO 10.00' 0.67 9.0 SYMPAFORCE 35/20-20 2.67 . 9.0. . SYMPAFORCE 35/20-20 4.67 9.0 SYMPAFORCE 35/20-20 7.33 . 9.0 SYMPAFORCE 35/20-20 10.67' TO 12.00' . . 1.33 . 10.0 . SYMPAFORCE 55/30-20 2.67 • 10.0 SYMPAFORCE 35/20-20 4.67 . 10.0 SYMPAFORCE 35/20-20 6.67 .10.0 SYMPAFORCE 35/20-20 9.33 10.0 SYMPAFORCE 35/20-20 12.67' TO 13.33' 0.67 11.5 . . SYMPAFORCE 55/3020 2.00 11.5 SYMPAFORCE 55/30-20 4.00 11.5 SYMPAFORCE 55/30-20 6.00 11.5 SYMPAFORCE 35/20-20 8.00 • 11.5 SYMPAFORCE 35/20-20 10.67 • 11.5 SYMPAFORCE 35/20-20 FORTRAC 55/30-20 MAY BE USED IN PLACE OF SYMPAFORCE 55/30-20 FORTRAC 35/20-20 MAY BE USED IN PLACE OF SYMPAFORCE 55/20-20 SRWa11 (ver 1.1 June 1995) Page 1 LN 95050839 Licensed to: STEVE CROSBY RETAINING WALLS COMPANY 1531 GRAND AVENUE SAN MARCOS, CA 92069 (619) 471-2500 License Number: 95050839 Project Identification: Project Name: PIRINEOS POINTE CARLSBAD Section: Data Sheet: S Owner: - Client: Prepared by: RETAINING WALLS COMPANY NORTH •:'' '•- Date: February 08 2002 Time: 10:07:29 AN Data file: c:\srwalll\al6grav Type of Structure: Gravity Segmental Retaining Wall Structure Criticality: Non-critical Design Methodology: NMA Method Wall Geometry: Design Wall Height (ft) .' 2.67 Embedment Wall Height (ft) 0.5 Exposed' Design Wall Height (ft) ' 2.17 Minimum Levelling Pad Thickness (ft) 0.5 ' Number of Segmental Wall Units - 4 Hinge Height (ft) 2.67 Base Inclination (degrees) horizontal Wall' Inclination (degrees) S ' 7.1 , S Slopes: - S Front Slope (degrees) - S - horizontal S S Back Slope (degrees). S 18.4 , SRWa11 (ver 1.1 June 1995) Uniformly Distributed Surcharges:.' Live Load Surcharge Dead Load Surcharge Soil Data: Soil Description: Retained:Soil sand Levelling Pad Soil gravel Foundation Soil sand Page 2 LN 95050839 none none Friction Cohesion Angle Unit Weight (psf) (degrees) (pcf) N/A 30.0 120.0 N/A 4C.0 125.0 0.0 r 3C 0 120.0 Segmental Unit Name: Default segmental unit properties Segmental Unit.Data: Cap Height (in) none Unit Height (in) 8.0 Unit Width (in) 16.0 Unit Length (in) 18.0 Setback (in) 1.•0 Weight (infilled) (lbs) 167.0 Unit Weight (infilled) (pcf). 125.3 Center of Gravity (in) 8.0 Secimental Unit Interface Shear Data: Properties Peak Strength Criteria Deformation Criteria Minimum (lbs/f t) 500.0 • 500.0 Friction Angle (degrees) 45.0 45.0 Maximum (lbs/ft) 2000.0 2000.0 Coefficients of Earth Pressure and Failure Plane Orientations: Retained Soil ([<a) 0.329 Retained Soil (Ka horizontal component) 0.321 Orientation of failure plane from horizontal (degrees) 47.8 SRWa11 (ver'l.l June 1995) Results of External Stability Analyses: Calculated FOS Sliding 1.91 FOS Overturning 2.89 FOS Bearing Capacity 10.63 Base Footing Width (B!) .(ft) 1.83 Base Eccentricity (e) (ft)' 0.3 Note: calculated values MEET ALL design criteria Page 3 LN 95050839 Design Criteria 1.5 OK 2.00K 2.00K N/A N/A Detailed Results of External Stability Analyses: Calculated Values: Total Horizontal Force (lbs/ft) ' , 137.2 Total Vertical Force (lbs/ft) ' 445.3. Sliding Resistance (lbs/ft) 261.6 Driving Moment (lbs-ft/ft) 122.1 Resisting Moment (lbs-ft/ft) 352.6 Bearing Capacity (psf) ' 3857.2 'Maximum Bearing Pressure (psf) " ' ' 363.0 Results of Facing Stability Analyses: SRW Heel Geosynthetic FOS FOS FOS Unit Elev Type Over- Shear Shear. # ' (ft) turning (peak) (deformation) >1.5 >2.5 N/At 4 2.0 none 39.05 71.48 N/A 3 1.33 none 10.37 21.12 N/A .2 0.67 none 4.88 10.83 N/A 1 0.0 none 29 6.91 N/A Note: calculated values MEET ALL design criteria , Detailed Results of Facing Stability Analyses (Moment and Shear): SRW Heel Geo Drive Resist Shear Shear Shear Unit Elev Type Moment Moment Load Capacity Capacity # (ft) , (lbs-ft/ft) (lbs -ft/ft) (lbs/ft) (lbs/ft) (lbs/ft) (peak) ' (deformation) +out -in N/A 4 2.0 none 1.9 , 74.2 8.6 611.3 N/A 3. 1.33 none 15.2 157.7 34.2 722.7 N/A 2 ' 0.67 none 51.3 250.5 77.0 834.0 N/A 1 ' ' 0.0 none 121.6 , 352.6 136.8 945.3 N/A Page LW 95050839 7.1 degrees SS ..S.v 2.67 ft Project Identification: Project Name: PIRINEOS POINTE CARLSBAD Section: 5 Data Sheet: * Owner: Client: Prepared by: RETAINING WALLS COMPANY NORTH Date: February 08 2002 Time: 10:07:29 AN • S Data file: c:\srwa111\a16grav SRWa11 (ver 1.1 •June 1995) Licensed to: STEVE CROSBY RETAINING WALLS COMPANY 1531 GRAND AVENUE SAM MARCOS, CA 92069 V (619) 471_2500 V V V License Number: 95050839 V & . jg- Pagel LN 95050839, Project Identification: Project Name: PIRINEOS POINTE. CARLSBAD Section: Data Sheet: Owner: V V V V V Client: V V V V V V.. Prepared by: RETAINING WALLS COMPANY NORTH V V Date: February 08 2002 V Time: 10:11:05 AM - V V Data file: c:\srwalll\al6sympa - Type of V VStructure: V Geosynthetic-Reinforced Segmental. Retaining Wall Structure Criticality: son-critical V V Des.ign Methodology: NCMA Method A V V V V Wall Geometry: V Design Wall Height (ft) 4.0 Embedment Wall Height (ft) V V 0.5 V Exposed Design Wall Height (ft) 3.5 Minimum Levelling Pad Thickness (ft) 0.5 V Number of Segmental Wall Units 6 Hinge Height (ft) 4.0 V Base Inclination (degrees) horizontal V Wall Inclination (degrees) 7.1 V Slopes: V V Front Slope (degrees) horizontal Back Slope (degrees) .18.4 SRWa11 (ver .1.1 June 1995) Uniformly Distributed Surcharges: Live Load Surcharge (psf) Dead Load Surcharge Soil Data: Soil Description: ReiñforcedSoii sand: Retained Soil sand . Levelling Pad Soil gravel . Foundation soil sand I) Page •2 LW 95050839 120 none Friction Cohesion Angle Unit Weight (psf) (degrees) (pcf) N/A 30.0 120.0 N/A 300 120.0 N/A 40.0. 125.0. 0.0 30.0 120.0 Segmental Unit Name: Default segmental unit properties Segmental Unit Data: . . . •• •.• Cap Height (in) none Unit Height (in) • 8.0 Unit Width (in) 16.0 Unit Length (in) 18.0 • • Setback (in) 1.0 Weight (infilled) (ibs) 167.0 • . S Unit Weight (irifilled) (pcf) 125.3 5 . S • Center of Gravity (in) 8.0 - S Segmental Unit Interface Shear Data.- Properties • Peak Strength Criteria Defcrrnation Critefia Minimum (lbs/ft) 500.0 • 500.0 Friction Angle (degrees) 45.0 45.0 Maximum (lbs/ft.) 2000.0 . 2000.0 Geosynthetic Reinforcement Types and Number: S Type Number • Name S 1 1 Sympaforce FS 35 2 0 • Sympaforce SF 55 3 0 Sympaforce SF 80 SRWai1 (ver1.1 June 1995) Geosynthetics Properties: Strength and Polymer Type: Index Tensile Strength (lbs/It) Polymer Type Page LN 95050839 Type 1 Type 2. Type 3 2627.0 3731.0 5583.0 polyester polyester polyester Partial Material Safety Factors: Type 1 . Type 2 Type 3 Creep :.: . 1.59 1.59 1.61 Biological Degradation 1.00 . 1.00 1.00 Chemicäl.Degradation . . 1.10 1.10 1.10 Construction Site Damage 1.15 1.08 1.08 Material;Uncertainty :. 1.50 1.50 1.50 Long 'Term Design Strength: Type 1 Type 2 Type 3 LTDS (lbs/It) .. .. . 870.7 1316.8 1946.0 Coefficient of Interactiàn: Type 1 Type 2 Type 3 Peak Load Criterion 0.72 0.72 0.75 Deformation Criterion 0.72 0.72 - 0.75 Coefficient of Direct Sliding: Type 1 Type 2 Type 3 Peak. Load Criterion • 0.75 1 0.8. • 0.85 Connection Strength: Type 1 Type 2 Type 3 Peak Strength Criterion: . Minimum .(lbs/ft) . 500.0 • 500.0 • 500.0 Friction Angle (degrees) 28.0 • 28.0 • 28.0 • Maximum (lbs/ft) . . . 2000.0 3000.0 3000.0 Deformation Strength Criterion: Minimum (lbs/It) • 500.0 500.0 500.0 Friction Angle (degrees) • 28.0 28.0 28.0 Maximum (lbs/It) 2000.0 3000.0 3000.0 "SRWall (ver 1.1 June 1995) Page 4 LN 95050839 Ilk gr Geosynthetic-Segmental Retaining Wall Unit -. Interface Shear Strength:'. Type 1 Type 2 Type 3 Peak Strength Criterion: S Minimum (lbs/ft) 500.0 5000 500.0 Friction Angle (degrees) 27.0 27.0 27.0 Maximum (lb/ft) 2000.0 2000.0 2000.0 Deformation Strength Criterion: Minimum (lbs/ft) 500.0 500.0 500.0. Friction Angle (degrees) 27.0 27.0 27.0 Maximum''(lb's/ft) . 2000.0 2000.0 2000.0 Coefficients of. Earth Pressure and Failure Plane Orientations Reinforced Soil (1(a) . 0.329 Reinforced Soil (Ka horizontal component) 0.321 Orientation of failure plane from horizontal (degrees) 47.8 Retained Soil (1(á) . "'' 0.329 Retained Soil. (Ka horizontal component) 0.321 Orientation of failure plane from horizontal (degrees) 47.8 Results of External Stability Analyses: Calculated Design Criteria FOS Sliding '.1 ': 1.97 '''15 OK FOS Overturning S 4.51 . ' 2.0 OK FOS Bearing. Capacity 9.26 25 OK Bate Reinforcement Length (L) (ft) 4.5 24 OK Bse'Eccentricity (e) (ft) 0.25 N/A Base Reinforcement Ratio (L/H) 1.13 0.6 OK Note: calculated values MEET ALL design criteria Detailed Results of External Stability. Analyses: Calculated Values: Total Horizontal Foce (lbs/ft)' 703.4 Total Vertical Force (lbs/ft) . 2402.3 Sliding* Resistance (lbs/ft) 138.7.0 Driving Moment (lbs-ft/ft) S .1371.0 Resisting Moment (lbs-ft/ft) 6186.1 Bearing Capacity (psf) 6492.2 Maximum Bearing Pressure (psf) 700.8 k j1 SR1a11 (ver 1.1 June 1995)' .• Page 5 LN 95050839 Results of Internal Stability Analyses: SRW Geosyn Elev Length Anchor FOS FOS FOS FOS Layer Unit Type (ft) (ft) Length Over- Pullout Pullout Sliding Spacing (ft) stress (peak) (def) (peak) (ft) >1.0 >1.0 >1.5 N/A . >1.5 <2.67 3 1 1.33 4.5 2.12. 1.89 1.51 N/A 2.97 OK Note: calculated values MEET ALL design criteria Detailed Results of Internal Stability Analyses: SRW Geosyn Elev Long Term Tensile Pullout Pullout Sliding. Sliding Unit Type . (ft) . Design .Load Capacity. Capacity Force Capacity Strength (lbs/ft) (peak) (def) (lbs/ft) .(lbs/ft) (lbs/ft) (lbs/ft) (lbs/ft). 3 . 1 1.33 870.7 461.8 695.9 N/A 423.2 . 1258.5 Results of Facina Stability Analyses: SRW Heel Geosynthetic . FOS FOS FOS . FOS . FOS Unit Elev. ..Type Over- Shear Shear Connection Connection (ft) .. turning (peak) (deformation) (peak) (deformation) > 1.5 > 1.5 N/A- > 1.5 N/A .6 3.33 none 7.1 17.87 . N/A 5 2.67 none 3.19 8.45 . N/A - - 4 2.0. none 1.95 5.42 N/A - - 3 1.33 1 1.36* 3.04 N/A 1.6 N/A 2 0.67 none 2.12 - N/A - - 1. 0.0 none 2.18 - N/A Note: * value does NOT MEET design criterion (1 occurrences) Detailed Results of Facing Stability Analyses (Moment and Shear): SRW . Heel. Geo Drive Resist Shear Shear Shear Unit Elev Type Moment Moment Load Capacity Capacity (ft) (lbs-ft/ft) (lbs-ft/ft) (lbs/ft) (lbs/ft) (lbs/ft) (peak) (deformation) 4-out -in N/A 6 -3.33 - none 10.5 74.2 34.2 611.3 N/A 5 2.67 . none 49.4 157.7 85.5 722.7 N/A 4 2.0 none 128.3 250.5 153.9 834.0 N/A 3 .. 1.33 1 258.5 352.6 239.5 .726.9 N/A 2 . 0.67 none 451.4 955.1 -119.7 1056.7 N/A 1 0.0 none 718.4 1.566.9. 0.0 1168.0 N/A Detailed Results of Facing Stability Analyses (Connections): SRW Heel Geo Connection Connection . Connection Unit Elev Type Load Capacity Capacity /1 (ft) (lbs/ft) (peak) (deformation) (lbs/f t) (lb.sift) N/A 3 1.33 1 461.8 736.8 N/A SRWall (rer 1.1 June 199.).. . Page 6. : . -.. . LN 95050839 Project IdentificatiOn: . . Project Name: PIRINEOS POINTE CARLSBAD •Section: Data Sheet: Owner: Client: • Prepared by: RETAINING WALLS COMPANY NORTH . • Date: February 08 2002 Time: 10:11:05 AM Data file: c:\srwa111\a16sympa SRWa11 (ver 1.1 June 1995) Licensed to: STEVE CROSBY RETAINING WALLS COMPANY 1.531 GRAND AVENUE. SAM MARCOS, CA 92069 (619) 471-2500 Page 1 LW 95050839 License Number: 95050839 Project Identification: . Project Name:' PIRIOS POINTE CARLSD Section: Data Sheet: Owner— Client: Prepared by: RETAINING WALLS COMPANY NORTH . ... Date: . February 08 2002 Time: 10:11:05 AM Data file: c:\srwalll\al6syinpa . . '- Type of Structure'::-. Geosynthetic-Reinforced Segmental Retaining Wall Structure Criticality: Non-critical . . . Design Methodology: . NMA Method A . . ...... Wall Geometr Design Wall Height (ft) .. 6.67 Embedment Wall Height' (ft) 0..5 Exposed Design Wall Height (ft) 6.17 Minimum Levelling Pad Thickness (ft) 0.5 Number of Segmental Wall Units 10 Hinge Height (ft) ' 6.67 Base' Inclination (degrees) . -horizontal Wall Inclination (degrees) . 7.1 Slopes: Front 'Slope (degrees) . . horizontal Back Slope (degrees) ' 18.4 SRWa.11 'ver 1.1 June .1995) Uniformly Distributed Surcharges: Live Load Surcharge (psf) Dead Load Surcharge Soil Data: Soil 'Description: Reinforced Soil sand Retained Soil sand Levelling Pad Soil gravel Foundation Soil sand . Page .2 LN 95050839 U 120 none Friction Cohesion Angle Unit Weight (psf) (degrees) (pcf) N/A 30.0. 120.0 N/A .30.0 120.0 N/A 40.0 .. 125.0. 0.0 30.0 120.0 Segmental Unit Name: Default segmental unit properties Segmental Unit Data: . . Cap Height (in) . none Unit Height. (in) 8.0 . Unit Width (in) . 16.0 Unit Length (in) 18.0 Setback (in) 1.0 Weight (infilled) (ibs) 167.0 Unit Weight (infilled) (pcf) 125.3 Center of Grávity (in) 8.0 . . . . Segmental Unit Interface Shear Data: - Properties . Peak Strength Criteria Defcrmation Criteria Mininum (lbs/ft) 500.0 .500.0 Friction Angle (degrees) 45.0 : 45.0 Maximura (lb/ft) 2000.0 2000.0 Geosvnthetic Reinforcement Tvoes and Number: Type Number Name 1 2 Sympaforce FS 35 2 0 Sympaforce SF 55 3 0 Sympaforce SF 80 SRWa11 (ve.r 1.1 June 1995) . Page 3 LN 95050839 Geosynthetics Properties: . . strength and Polymer Type: Type 1 Type 2 Type 3 Index Tensile Strength (lbs/ft) 2627.0 3731.0 5583.0 Polymer Type polyester polyester polyester Partial Material Safety-Factors: Type 1 Type 2. Type .3 Creep .. 1.59, 1.59 1.61 Biological Degradation 1.00 1.00 1.00 Chemical Degradation S 1.10 1.10 ' 1.1.0 Construction Site Damage 1.15 1.08 . 1.08 MaterialtJncertainty. 1.50 1.50 , 1.50 Long' Term Design Strength: Type 1 Type 2 Type 3 LTDS (lb's/ft) - '.. " . 870.7 . 1316.8 1946.0 Coefficient of Interaction: Type 1 Type 2 Type 3 Peak Load Criterion ' 0.72 ' 0.72 0.75 Deformation Criterion 0.72 0.72 . 0.75 Coefficient of Direct, Sliding: , Type 1 Type 2 Type 3 Peak Load Criterion S , , .0.75 0.8 ' : 0.85. Connection Strength: Type 1 . ' Type 2 ' Type 3 Peak Strength Criterion: Minimum (lbs/ft) 5 500.0 500.0 500.0 Friction Angle (degrees) 28.0 28.0 - 28.0 ' 'Maximum (ibsift) 5 2000.0' ' 3000.0, 3000.0 Deformation Strength Criterion:' S Minimum (lbs/ft) 500.0 500.0 ' 500.0 Friction Angle (degrees) 28.0 28.0 28.0 Maximum (lbs/ft) 2000.0 3000.0 3000.0 SRWa11 (zer 1.1 June 1995) '.' Page 4 LN 95050839 Geosynthet,ic-Segmental Retaining Wall Unit Interface Shear Strength: Type I Typ.2 Type 3 Peak Strength Criterion: Minimum (lbs/ft) 500.0 500.0 500.0 Friction Angle (degrees) 27.0 27.0 27.0 Maximum (lbs/ft) 2000.0 '2000.0 2000.0' Deformation Strength Criterion: Minimum (lbs/ft) ' 500.0 500.0 500.0 Friction Angle (degrees) 27.0' :27.0 27.0 Maximum (lbs/ft)'. •'. 2000.0 2000.0 2000.0 Coefficients of Earth Pressure and Failure Plane -Orientations: Reinforced Soil (Ka) 0.329 Reinforced Soil (Ka horizontal component) 0.321- Orientation of failure plane from horizontal (degrees: 47.8 Retained Soil :(K) - ' ' 0.329 - Retained SOil (Ka horizontal component)' 0.321 Orientation Of failure plane from horizontal (degrees) 47.8 Results' of External Stability Analyses: Calculated Design Criteria FOS Sliding ' ' ' 1.96 1.5 OK FOS Overturning '• " ' ' 4:16 2.0 OK FOS Bearing Capacity' ' 7.92 ' 2.5-6K Base-Reinforcement Length (L) (ft 6.5 • 40 OK Base Eccentricity (e) (ft) - • 0.36 , N/A Base Reinforcement Ratio (L/H) 0.97 • 0.60K Note: calculated values MEET ALL design criteria Detailed Results of External Stability Analyses: Calculated Values: . • Total Horizontal Force (lbs/ft) . '1713.4 TotalVertical Force (lbs/ft) 5811.6 Sliding Resistance (lbs/ft) ' 3355.3 Driving Moment (lbs-ft/fl) 531.0.6 Resisting Moment (lbs-ft/ft) - 22093.1 Bearing Capacity (pf) 8867.2 Maximum Bearing Pressure (psf) 1120.0 SRWa11 (ver 1.1 June 1995) :. Page 5 LN. 95050839 Results of, Internal Stability Analyses: SRW Geosyn Elev Length Anchor FOS FOS FOS FOS Layer Unit Type (ft) (ft) Length Over- Pullout Pullout Sliding Spacing '(ft) stress (peak) (def) (peak) (ft) >1.0 >1.0 >1.5 N/A >1.5 <2.67 7 1 4.0 . 6.5 2.04 1.89 1.75 N/A 3.01 OK 3 1 1.33 6.5 4.12 . 1.34 3.91 N/A 2.09 OK . Note: calculated values MEET ALL design criteria Detailed Results of Internal Stability Analyses: .SRW Geosyn Elev . Long Term. Tensile Pullout Pullout Sliding Sliding 'Unit Type (ft) Design •.. Load Capacity Capacity Force Capacity . ; -.'. . Strength (lbs/f t). (peak) . (def) " (lbs/it) (lbs/f t) (lbs/ft) . (lbs/ft) . (lbs/ft) 7 1 . . 4.0 ' 870.7 461.8 . 806.5 N/A 560.5 1687.4 3 1 . 1.33 870.7 650.0 2539.6 N/A 1260.7 2630.2 Results of Facing Stability Analyses: •.. SRW Heel Geosynthe tic FOS FOS FOS . . , FOS ' FOS 'Unit Elev . Type . 'Over- Shear Shear Connection Connection # (ft) . ' turning (peak) (deformation) (peak) (deformation) > 1.5 > 1.5 N/A ' > 1.5 N/A 10 6.0 none 7.1, 17.87 N/A 9 5.33 none 3.19 8.45 N/A 8 4.67 none 1.95 . 5.42 N/A 7 4.0 . 1' ' 1.36* OI- 3.04 N/A ' ' ' 1.6 ' ' N/A 6 3.33 none..: ' 2.12 - N/A 5 • 2.67 none . 2.18 - N/A 4 2.0 none 2.04 9.35 N/A - - 3 1.33 - 1. . . • 1.85 3.28 N/A 1:5* /_ N/A 2. 0.67 none 1.94 - N/A - - 1 0.0 none • 1.91 >99 N/A - Note: * value does 'NOT MEET design criterion (2 occurrences) 0 Detai-led Results of Facing Stability Analyses (Moment and Shear) SRW Heel Geo Drive Resist Shear Shear Shear' Unit Elev Type Moment Moment • Load Capacity Capacity (ft) • (lbs -ft/ft) (lbs-ft/fL) (lbs/ft) (lbs/ft) (lbs/ft) • . (peak) (deformation) -. • +out -in N/A 10 6.0 none 10.5 74.2 34.2 611.3 N/A 90 533 none 49.4 157.7 85.5 722.7 N/A 8 ' 4.67 - none 128.3 250.5 . 153.9 834.0 N/A 7 4.0 1 • 258.5 352.6 . 239.5 • 726.9 . N/A 6 • 3.33 none 451.4 955.1 • -119.7 1056.7 N/A 5 ' 2.67 none 718.4 1566.9 0.0 1168.0 N/A 4 • 2.0 none 1071.0 ' 2188.0 136.8 1279.3 N/A 3 • 1.33 1 1520.5 2818.3 • 290.8 953.8 N/A 2 0.67 ' none 2078.3 4038.4 -188.2 1502.0 N/A 1 • 0.0 none 2755.9 5267.8 0.0 • 1613.3 N/A SRWa11 (ver 1.1 June 199 5), Page 6 - LW 95050839. Detai1d Results of Facing Stability Analyses (Connections): SRW Heel • Geo Connection Connection - Connection Unit Elev Type Load Capacity Capacity (ft) • (lbs/ft) (peak) (deformation) • (lbs/ft) (lbs/ft) N/A 7 . 4.0 1 461.8 736.8 N/A 3 1.33 1 650.0 973.6 • . N/A SRWa11 (ver lii June 1995) Page 7 LN 95050839 Project Identification: Project Name: PIRINEOS POINTE CARLSBAD Section: Data Sheet: Owner: Client: Prepared by: RETAINING WALLS COMPANY NORTH Date: February 08 2002 Time: 10:11:05 AM Data file: c:\srwa111\a16sympa 3 .5, SRWa1J. (ver 1.1 June 1995) . Page 1. LN 95050839 Licensed' to: STEVE CROSBY RETAINING WALLS COMPANY 1531 GRAND AVENUE SAN MARCOS, CA 92069 (61-9) 471-2500 License Number: 95050839 . Project Identification: Project Name: PIRINEOS POINTE CARLSBAD Section: . . Data Sheet: . 0 Owner: '' . . .• ..... Client: S •,, - . .. . . 'O, Prepared by: RETAINING WALLS COMPANY NORTH Date: . February 08 2002 Time: 10:11:05 AN Data file: c:\srwa111\a16syinpa . . . . . . .. " Type of;'•Structure: ..... Geosynthetic-Reinforced Segmental Retaining Wall Structure Critidality: Non-ôritical Desian Methodoloav: '.' NMP Method A . . .' . . Wall Geornetr Design Wall Height (ft) 8.0. S • Embedment Wall Height (ft) 0.5 Exposed Design Wall Height (ft) 7.5. Minimum Levelling Pad Thickness (ft) 0.5 Number of Segmental Wall Units 12 Hinge Height (ft) . 8.0 Base Inclination (degrees) horizontal' Wall Inclination (degrees) . 7.1 Slopes: Front Slope (degrees) horizontal Back Slope (degrees) 18.4 SRWa11 (ver 1.,1 June 1995) Uniformly Distributed Surcharges: Live Load Surcharge (psf) Dead Load Surcharge Soil Data: Soil Description: Reinforced Soil sand' RetainëdSbil sand Levelling Pad Soil gravel FoundationSoil sand: Page 2. LN 95050839 120 none Friction Cohesion Angle Unit Weight (psf) (degrees) (pcf) N/A 30.0 . 120.0 N/A 30.0 120.0 N/A 40.0 - .125.0 0.0 30.0 120.0 Segmental Unit Name.: Default segmental unit properties Segmental. Unit Data: Cap Height (in) . none Unit Height (in) 8.0 Unit Width (in) 16.0 Unit Length (in) . 18.0 Setback (in) 1.0 Weight (irifilled) (ibs) 167.0 Unit Weight (infilled) (pcf) 125.3 Center Of Gravity (in) 8.0 Segmental Unit Interface Shear Data: . . . Properties Peak Strength Criteria Deformation Criteria Minimum (lbs/ft) 500.0. .500.0 Friction-Angle (degrees) 45.0 . . 45.0 Maximum. (lbs/ft) 2000.0 ., 2000.0 Geosynthetic Reinforcement Types and Number: Type Number Name 1 3 Sympaforce FS 35 2 0 Sympaforce SF 55 3 0 Sympaforce SF 80 - . SRWa11 (ver 1.1 June 1995). •• Page 3 LN 95050839 Geosynthetics Properties: Strength and Polymer. Type: Type I Type 2 Type 3 Index Tensile Strength (lbs/ft) 2627.0 3731.0. 5583.0 Polymer Type polyester polyester polyester Partial Material Safety Factors: Type 1 Type 2 Type .3 Creep •. . •, * .1.59 . 1.59 . 1.61 Biol'ogical Degradation 1.00 1.00 1.00 Chemical Degradatioti . 1.10 1.10 1.10 . . Construction Site Damage . 1.15 1.08 . • 1.08 Material Uncertainty . 1.50 1.50 1.50 Long Term Design Strength: Type 1. Type 2 . Type 3 LTDS (lbs/ft) .. 870.7 . 1316.8 1946.0 Coefficient of Interaction.-_ Type 1 Type 2 Type .3 Peak Load Criterion. • • 0.72 0.72 • 075 Deformation Criterion • - 0.72 • 0.72- • 0.75 .. • Coeffióient,of Direct Sliding: Type-1 Type 2 • Type .3 Peak LOad Criterion..... . • 0.75 0.8 0.85 Connection Strength: . Type 1 Type 2 Type 3 Peak Strength Criterion: • Minimum (lbs/ft) :. 500.0 • 500.0 500.0 Friction Angle (degrees) 28.0 28.0 28.0 Maximum (lIâ/ft) . - : 2000.0 • . 3000.0 -. 3000.0 Deformation Strength Criterion: . Minimum (lbs/ft) 500.0 w 500.0 • 500.0 Friction Angle (degrees) 28.0 . 280 . 28.0 Maximum (lbs/ft) 2000.0 3000.0 3000.0 SRWa11 (ver 1.1 June 1995) Page 4 LI'J 95050839 Geosynthetic-Segmental Retaining Wall Unit Interface Shear Strength: Type 1 Type 2 Type 3 Peak Strength Criterion: Minimum. (lbs/ft) 500.0 500.0 500.0 Friction Angle (degrees) 27.0 27.0 27.0 Maximum (lbs/ft) . 2000.0 2000.0 2000.0 Deformation Strength Criterion: Minimum (lbs/ft). . 500.0 500.0 500.0 0 Friction Angle (degrees) 27.0 27.0 27.0 Maximu (lbs/ft) 2000.0 2000.0 200.0 'Coefficients. of Earth Pressure and Failure Plane Orientations: Reinforced Soil (Ka) 0.329 Reinforced Soil (Ka horizontal component) 0.321 Orientation of failure plane from horizontal (degrees) 47.8 Retained Soil .°(Ká) 0.329 Retained Soil (Ka horizontal component) . ... 0.321 Orientation of failure plane from horizontal (degrees) 47.8 Results of External Stability Analyses: Calculated Design Criteria FOS Sliding 1.95 1.5 OK FOS Overturning . 0 4?07 2.0 OK FOS Bearing Capacity; 0 7.58 . 2.5 OK Base Reinforcement..Length (L) (ft) 7.5 4.81 0K Base Eccentricity (e) (ft) 0.42 N/A Base Reinforcement Ratio (L/H) 0.94 0.6.0K Note: calculated values MEET ALL design criteria Detailed Results of External Stability Analyses: Calculated Values: Total Horiohtal Force (lbs/ft) 2381.5 Total Vertical Force (lbs/ft) 0 8058.6 Sliding Rsistance (lbs/ft) 4652.7 0 Driving Moment (lbs-ft/ft) 8736.0 Resisting Moment (lbs-ft/ft) . 35579.5 Bearing Capacity (psf) 0 10058.8 Maximum Bearing Pressure (psf) 0 1327.1 SRWa11 (ver 1.1 June 1995) ' Page 5 LN 95050839 Results of Internal Stability 'Analyses: SRW Geosyn Elev Length Anchor FOS FOS 105 FOS Layer Unit Type (ft) (ft) Length Over- Pullout Pullout Sliding Spacing (ft) stress (peak) 'def) (peak) (ft) > 1.0, > 1.0 > 1.5 N/A > 1.5 < 2.67 9 1 5.33 7.5 2.0 1.89 1.86 N/A 3.03 OK 5 1 2.67 7.5 ' 4.08 1.57 . 4.79 N/A 2.19 OK 2 1 0.67 7.5 5.65 .1.66 8.79 N/A 1.82 OK Note: calculated values MEET ALL design criteria Detailed Results of Internal Stability Analyses: SEW Unit # 9 5 2 Geosyn Type 1 1 1 Elev. , (ft)' , . 5.33 2.67 ' 0.67 Long Term'' Design .. 'Strength' (lbs/ft) , 870.7 870.7 870.7 Tensile Load' '(lbs/ft) , 461.8 553.8 523.9 Pullout Capacity (peak) (lbs/ft) 857.5 ' 2651.9 4602.4 Pullout Capacity (def. (Ibsift) N/A N/A N/A Sliding Force . (lbs/ft) ' 636.2 1372.0 2103.4 Sliding Capacity (lbs/ft) 1928.9 3010.3 3821.4 Results of Facing Stability Analyses: SEW Heel Geosynthetic 105 FOS FOS FOS .105 Unit Elev Type ' Over-., Shear Shear Connection Connection # (ft) ' turning . (peak) (deformation) (peak) (deformation) > 1.5 , > 1.5 N/A > 1.5 ' N/A 12 7.33 none 7.1 17.87 N/A - - - 11 6.67 ' none ' 3.19 ' 8.45 N/A - - 10 6.0 none ' 1.95 5.42 N/A - 9 5.33 . 1' ' 1.36* 3.04 N/A 1.6 N/A 8 4.67 none " 2.12 - N/A - 7 4.0 none ' ' ' 2.18 :'. , ' ' N/A 6 3.33 none , 2.04 9.35 N/A - 5 2.67 .1 "1.85 3.28 N/A 1.76 ' N/A 4 2.0 none ' 1.94 -' , N/A 3 1.33 none '1.91 16.77 N/A - - 2 0.67 1' ' 1.83 , 3.73 N/A . 2.2 N/A 1 0.0 none 1.85 - , N/A - - Note: * value does NOT MEET design criterion (1 occurrences) Detailed Results of Facing Stability Analyses (Moment and Shear): SRW ' " Heel Geo . Drive Resist Shear Shear Shear Unit Elev ' Type. Moment Moment Load Capacity. Capacity (ft) . (lbs-ft/ft) (lbs-ft/ft) (lbs/ft) (lbs/ft) (lbs/ft) (peak) (deformation) 4-out -in N/A 12 7.33 none 10.5 74.2 34.2 611.3 ' N/A 11 6.67 none ' 49.4 157.7 85.5 722.7 N/A 10 6.0 none , 128.3 250.5 153.9 834.0 N/A 9 5.33 1 258.5 ' 352.6 .239.5 726.9 N/A 8 . 4.67 none 451.4 955.1 ' -119.7 1056.7 N/A 7 4.0 ' none 718.4 1566.9 0.0 1168.0 N/A 6 ' 3.33 none - 1071.0 2188.0 136.8 1279.3 ' N/A 5 2.67 1 1520.5 2818.3 290.8 953.8 N/A 4 2.0 ' none' 2078.3 4038.4 -91.9 1502.0 N/A 3 1.33 . none ,. 2755.9 5267.8 96.2' 1613.3 N/A 2 0.67 1 . 3564.6 6506.5 301.5 1124.0 N/A 1 0.0 none 4515.8 8334.9 , 0.0 1836.0 N/A SRWa11 (ver 1.1 June 1995) Page 6 LW 95050839 Detailed Results of Facing Stability Analyses' (Connections): SRW Heel Geo Connection Connection Connection Unit Elev Type ;Load Capacity Capacity (ft) (lbs/f t) (peak) (deformation) (lbs/f t) (lbs/f t) N/A 9 5.33 1 461.8 736.8 N/A 5 2.67 1 553.8 973.6 N/A 2 0.67 1 523.9 1151.2 N/A SRWa11 (ver. 1.1 June. 1995) . . .. Page .7 LN 95050839 Project" Identification: Project Name: PIRINEOS POINTE CARLSBAD Section: Data Sheet: Owner: Client: :. Prepred by: RETAINING WALLS COMPANY NORTH Date: February 08 2002 Time: 10:11:05 AN Data file: c:\srwa111\a16sympa SRWa.11 (ver 1.1 June 1995) Page 1 LN 95050839 Licensed to: STEVE CROSBY RETAINING WALLS COMPANY 1531 GRAND AVENUE SAM MARCOS, CA 92069 (619) 471-2500 License Number: 95050839 Project Identification: Project Name: PIRINEOS POINTE CARLSBAD Section: Data Sheet: Owner: Client: Prepared by: RETAINING WALLS COMPANY NORTH Date: February 08 2002 Time: 10:11:05 AM Data file: c:\srwalll\al6sympa 1". Type of-.,St ucture.: Geosynthetic-Reinforced Segmental Retaining Wall Structure Criticality: Non-critical Dpsicin Mthodo1oav: NMA Method A Wall Geometr Design Wall Height (ft) 10.0 Embedment Wall Height (ft) 0.5 Exposed Design Wall Height (ft) 9.5 Minimum Levelling Pad Thickness (ft) 0.5 Number of Segmental Wall Units 15 Hinge Height (ft) 10.0 Base Inclination (degrees) . horizontal Wall. Inclination (degrees) 7.1 Slopes: Front Slope (degrees) horizontal Back Slope (degrees) . 18.4 SRWa11 (ver 1.1 June 1995) Uniformly Distributed Surcharges: Live Load Surcharge (psf) Dead Load Surcharge •. Soil Data: Soil Description Reinforced Soil sand" Retained Soil sand Levelling Pad. Soil gravel : Foundation Soil sand Page 2 LN 95050839 120 , none Friction Cohesion Angle Unit Weight ('psf) (aegrees) .(pcf) N/A .30.0 120.0 N/A 30.0• 120.0 ....... N/A •. . .40..0.... 1250, •;. 0.0 •.• '30-. 0 • • "-120.0 • • Segmental Unit Name: Default segmental unit properties Segmental Unit Data: . ap Height (in) none Unit Height (in) 8.0 Unit Width (in,) . 16.0 . .; Unit Length (in) . 18.0 • Setback (in) . 1.0 Weight (infilled) (lbs) . 167.0 . . Unit Weight (infilled) (pcf) 125.3 . Center of Gravity (in) . 8.0 . Segmental Unit Interface Shear Data: . .• ••• . . Properties Peak Strength Criteria Deformation Criteria Minimum (lbs/ft) 500.0 .500.0 Friction Angle (degrees) 45.0 45.0 Maximum (lbs/ft) 2000.0 2000.0 Geosvnthetic Reinforcement Tvoes and Number: Type Number Name 1 4 Sympaforce FS 35 2 0 . Sympaforce SF 55 3 0 Sympaforce SF 80 SRWa11 (ver 1.1 June 1995) Page 3 LN 95050839 Geosynthetics Properties: Strength and Polymer Type: Type 1 Type 2 Type 3 Index Tensile Strength (lbs/ft) 2627.0 3731.0 5583.0 Polymer Type polyester polyester polyester Partial Material Safety Factors: Creep Biological Degradation' ' Chemical Degradation Construction Site Damage Material Uncertainty Type 1 Type 2 Type 3 1.59 1.59 1.61 1.00, •• 1.00 1.00 1.10• 1.10 . 1..10 1.15 1:08 .., 1.08 1.50 1.50 ', 1.50 Long Term Design Strength: Type 1 Type 2 -Type 3- LTDS (lbs/ft) 870.7 • . 1316.8 • 1946.b Coefficient of Inteiaction: Type 1 Type 2 • '. Type 3 Peak Load Criterion • 0.72 - 0.72 • 0.75 ' 'Deformation Criterion - • 0.72 0.72 0.75 - Coeffiáient-of Direct Sliding: • Type 1 Type 2 ,' Type 3 Peak Load Criterion • . .0.75 0.8 0.85 Connection Strength: Type 1 Type 2 Type 3 Peak Strength Criterion: Minimum. (lbs/ft) - 500.0 500.0 ' 500.0 Friction Angle (degrees) • 28.0 28.0 28.0 Maximum (lbs/ft) . • 2000.0 3000.0 3000.0 - Deformation 'Strength Criterion: Minimum (lbs/ft) 500.0 500.0 500.0 Friction Angle (degrees) 28.0 28.0 - 28.0 Maximum (lbs/ft) 2000.0 3000.0 3000.0 3c SRWa11 (ver 1.1 June 1995) Page 4 LN 95050839 Geosynthetic-Segmental Retaining Wall Unit Interface Shear Strength: Type I Type 2 Type 3 Peak Strength Criterion: Minimum (lbs/ft) 500.0 500.0 500.0 Friction Angle (degrees) 27.0 27.0 27.0 Maximum (lbs/ft) 2000.0 2000.0 2000.0 Deformation Strength Criterion: Minimum (lbs/ft) 500.0 500.0 .560.0 Frictioh Angle (degrees) 27.0 27.0 27.0 Maximum (lbs/ft) 2000.0 2000.0 2000.0 Coefficients of Earth Pressure and Failure Plane Orientations: Reinforced Soil (Ka) 0.329 Reinforced Soil(Kahorizontal component) 0.321 Orientation of failure plane from horizontal (degrees) 47.8 Retained Soil .(Ka) 0.329 Retained Soil (Ka horizontal component) 0.321 Orientation of failure plane from horizontal (degrees) 47.8 Results of External Stability Analyses: Calculated Design Criteria FOS Sliding' . 1.95 1.5.0K FOS Overturning .. : 3.99 2.0 OK FOSBearing Capaity 7.24 2.50K Base Reinforcement Length (L) (ft) 9.0 6.0 OK Base Eccentricity (e) (ft) 0.5 N/A BaseReinforcemeñtRatio (L/H) 0.9 0.60K Note: calculated values MEET ALL design criteria Detailed Results of External Stability Analyses: Calculated Values: Total Horizontal Force (lbs/ft) 3587.3 Total Vertical Force (lbs/ft) 12107.4 Sliding Resistance (lbs/ft) 6990.2. Driving Moment (lbs-ft/ft) 16207.1 Reäisting Moment (lbs-ft/ft) 64598.3 Bearing Capacity (psf) 11848.7 Maximum Bearing Pressure (psf) 1636.0 SRWa11 (ver 1.1 June' 1995) S Page 5 LN 95050839 Results of Internal Stability'Analyses: SRW Geosyn Elev Length Anchor FOS FOS FOS FOS Layer Unit Type (it) (ft) Length Over- Pullout Pullout Sliding Spacing ft (ft) stress (peak) (def) (peak) (ft) >1.0 >1.0 >1.5 N/A >1.5 <2.67 12 . 1 7.33 9.0 1.93 1.89 2.01 N/A 3.07 OK 8 1 4.67 9.0 4.02 1.57 5.08 N/A 2.34 OK 5 1 2.67 9.0 5.58 1.36 7.53 N/A 1.98 OK 2 - 1 0.67 9.0 7.15 1.34 11.31 N/A 1.71 OK Note: calculated values MEET ALL design criteria Detailed Results of Internal Stability Analyses: SRW. Geosyñ El e' •. Long Term. ' . Tensile Pullout . Pullout - Sliding ' Sliding'. Unit Type (ft) .' Design.'. Load Capacity Capacity Force . . Capacity ft .' . . . . Strength , (lbs/ft) (peak) (def) - (lbs/it) (lbs/it) (lbs/it) (lbs/it) (lbs/it) ' 12 1 7.33 870.7 461.8 928.5 N/A .758.3 2325.0 8 1- ' 4.67' 870.7 553.8 ' 2815.0 N/A 1547.6 . '3614.3 5 1 2.67 870.7 .. 641.5 4832.8 N/A . 2319.1 4581.2 2 1 0.67. '870.7.. 652:1 7372.7 . N/A 3244.6' 5548.1 Results of Facing Stability Analyses: SRW Heel 'Geosynthetic 'FOS FOS FOS FOS FOS S Unit Elev Type Over- Shear Shear Connection Connection ft (ft) . turning (peak) (deformation) (peak) '(deformation) '> 1.5 , > 1.5 N/A >1.5 ' N/A - ' 15 9.33 none ' '71 17.87 N/A .14 '8.67 ' none ' 3.19 8.45 N/A - - 13 8.0. none . 1.95 5.42' N/A . - - S 12 7.33 . 1 . . 1:36* 3.04 N/A ' 1:6. 11 6.67 none , ' 2.12 - N/A -' 10 6.0 ' none 2.18 . - -N/A 9 5.33 ' none ' 2.04 ' 9.35 ' N/A - 8 4.67 1 ' 1.85 3.28 N/A 1.76 N/A 7 4.0 none 1.94 - N/A - - 6 3.33. none • 1.91 16.77 N/A , - - 5 2.67 1 1.83 3.73 N/A 1.79 . N/A 4 , 2.0 'none 1.85 - - N/A 3 1.33 , none 1.81 . 15.98 N/A ' - - 2 ' 0.67 1 1.74 . 3.42 N/A 2.04 N/A 1 0.0 none 1.73 ' >99 N/A Note: * value does NOT MEET design criterion (1 occurrences) S , , • 37 SRWa11 (ver 1.1 June 19.95')-.' '. Page 6 LW 95050839 Detailed Results of Facing Stability. Analyses (Moment and Shear): SRW Heel Geo Drive. Resist Shear Shear Shear Unit Elev Type Moment Moment Load Capacity Capacity # (ft) (lbs-ft/ft) (lbs-ft/ft) (lbs/ft) (lbs/ft) (lbs/ft) (peak) (deformation) +out -in N/A 15 9.33 none 10.5 74:2 34.2 611.3 N/A - 14 . 8.67 .. none 49.4 157.7 85.5 722.7 . N/A 13 : . 8.0 none 128.3 250.5 153.9 834.0 N/A 12 '. 7.33- " 1 258.5 . 352.6 239.5 726.9 N/A 11 ' 6.67 ' none . 451.4 955.1 -119.7 1056.7 N/A 10 . 6:0 •. none: .' 718.4 1566.9 0.0 1168.0 N/A 9 . . 5.33. ., none, . 1071.0 2188.0 136.8 1279.3 N/A 8 4.67 1 :': 1520.5 2818.3 290.8 9538 N/A 7 . 4.0.' none: 2078.3 4038.4 -91.9 . 15020 N/A 6 " ' 3.33. none z , 2755.9 5267.8 96.2 1613.3 N/A ' 5 '. .. . 2.67. . 1 " ': 3564.6 6506.5 ' 301.5 1124.0 ' N/A 'S 4 " ."':' none' '4515.8 8334.9 '-117.6' '1836.0 N/A 3. . 1.33"- . none .. ' 5621.0 10172.5 '121.9 1947.3 N/A 2 ' 0.67 ' 1 ''' 6891.6 12019.5 378.5 , 1294.2 14/A 1 0.0 ' none 8338.9 14456.2 0.0 2000.0 N/A '0 Detailed Results of Facing Stability Analyses (Connections)........' ... SRW ''Heel Geo Connection '-Connection Connection ' Unit ,. ' - Elev Type Load Capacity Capacity (if): • (lbs/ft) (peak) (defamation) (lbs/ft) (lbs/ft) 0 • . • N/A 12 '.. 7.33 • 1 , 461.8 , 736.8 N/A • : ' 8 . 4.67 , 1 . . 553.8 973..6 . • N/A 5 ' 2.67 1 , 641.5 ' 1151.2 N/A 2 . .: 0.67 ' " 1 .. ' 652.1 -, -1328.8 N/A ' .''" •' SRWal1 (ver 1.1 June 1995) Page 7. LN 95050839 7.1 degrees 10.0 ft _.L 0.15 ::ft -I-. -0.5 ft -j 9.0 ft Project Identification: S Project Name: PIRINEOS POINTE CARLSBAD Section: Data Sheet: - Owner: Client: Prepared by: RETAINING WALLS COMPANY NORTH Date: 5 February 08 2002 Time: 10:11:05 AM Data file: . c:\srwa111\a16sympa SRWa11 (ver 1.1 June 1995) Licensed to: STEVE CROSBY RETAINING WALLS COMPANY 1531 GRAND AVENUE SAM MARCOS, CA 92069 (619) 471-2500 Page 1 LN 95050839 C -k License Number: 95050839 Project Identification: Project Name: PIRINEOS POINTE CARLSBAD Section: Data Sheet: Owner: Client: Prepared by: RETAINING -WALLS COMPANY NORTH . . . . . .; . ,. . . .. . Date: February 08 2002 . . . . Time: 10:11:05 AN . . Data file: C: \windows\desktop\server\2-rwcn\pirone-i.\a16sympa. .. . ...; Type of Structure: Geosynthetic-Reinforced Segmental Retaining Wall Structure Criticality: Non-critical Design Methodology: NMA Method A Wall Geometr Design Wall Height (ft) Embedment Wall Height (ft) Exposed Design Wall Height (ft) Minimum Levelling Pad Thickness (ft) Number of Segmental Wall Units Hinge Height (ft) Base Inclination (degrees) Wall Inclination (degrees) 12.0 0.58 11.42 0.5 18 10.0 horizontal 7.1 Slopes: Front Slope (degrees.) horizontal Back Slope (degrees) 18.4 SRWa11. (ver 1. .1 June 1995) Uniformly Distributed Surcharges: Live Load Surcharge (psf) Dead Load Surcharge (psf) Soil Data: Soil Description: Reinforced Soil sand Retained Soil sand Levelling Pad Soil gravel Foundation Soil sand Page 2 LN 95050839 120 114 Friction Cohesion Angle Unit Weight (psf) (degrees) (pcf) N/A . . .• 30.0 120.0 N/A 30.0 120.0 N/A 40.0 125.0 0.0 30.0 120.0 Segmental Unit Name: Default segmental unit propert:ies. Segmental Unit Data: . . Cap Height (in.) none . Unit Height. (in) 8.0 . . . Unit Width (in) 16.0 .. Unit Length (in) 18.0 . . . Setback (in) 1.0 . Weight (infilled) (lbs) .167.0 Unit Weight (.i.nfil.ld) (pcf) 125.3 . . . . . ... Center of-Gravity (in.) 8.0 .. . . . . . Segmental Unit Interface Shear Data: Properties . Peak Strength Criteria Deformation Criteria Minimum (lbs/ft) 500 0 500 0 Friction Angle (degrees) 45.0 - 45.0 - Maximum (-lbs/ft) - - -. - -2000.0 - 2000,0 Geosynthetic Reinforcement Types and Number: .. - Type Number Name. .1 4 Sympaforce FS 35 -2 1 Sympaforce SF 55 3 0 - Sympaforce SF 80 . - . SRWa11 (ver 1.1 June 1995) Page 4 LN 95050839 Geosynthetic-Segmental Retaining Wall Unit Interface Shear Strength: Type 1 Type 2 Type 3 Peak Strength Criterion: Minimum (lbs/ft) 500.0 500.0 500.0 Friction Angle (degrees) 27.0 27.0 27.0 Maximum (lbs/ft) 2000.0 2000.0 2000.0 Deformation Strength Criterion: Minimum (lbs/ft) 500.0 500.0 500.0 Friction Angle (degrees) 27.0 27.0 27.0 Maximum (lbs/ft) 2000.0 2000.0 . 2000.0 Coefficients of Earth Pressure and Failure Plane Orientations: Reinforced Soil (Ka) . 0.329 Reinforced -Soil (Ka horizontal component) 0.321 Orientation of failure plane from horizontal (degrees) 47.8. Retained Soil (Ka) . 0.329 - Retained Soil (Ka horizontal component) . . .' .' 0.321 . Orientation of: failure plane from horizontal.'-(degrees).- 47.8 Results of External Stability Analyses: Calculated Design Criteria FOS Sliding 1.8 1.5 OK FOS Overturning 3.42 - 2.0 OK FOS Bearing Capacity 6.04 . 2.5 OK Base Reinforcement Length (L) (ft) 10.0 7.2 OK, Base Eccentricity (e) (ft) 0.71 N/A Base Reinforcement Ratio (LtH) 0.83 . 0.6 OK Note: calculated values MEET ALL design criteria Detailed Results of External Stability Analyses: Calculated Values: Total Horizontal Force (lbs/ft) 5479.7 Total Vertical Force (lbs/ft) 17104.0 Sliding Resistance (lbs/ft) 9875,. 0 Driving Moment (lbs-ft/ft) 30294.6 Resisting Moment (lbs-ft/ft) 103663.8 Bearing Capacity (psf) .. 12812.3 Maximum Bearing Pressure (pf) . 2121.4 SRWa11 (ver 1.1 June 1995) Page 1 LW 95050839 Licensed to: STEVE CROSBY tfjJ141rn RETAINING WALLS COMPANY 1531 GRAND AVENUE SAM MARCOS, CA 92069 619) 471-2500 S .License.Number: 95050839 Project Identification: Project Name: PIRINEOS POINTE CARLSBAD Section: Data Sheet: Owner: Client: S S Prepared by: RETAINING WALLS COMPANY NORTH . .. ... Date: February 08 2002 . Time: - 10:11:05 AN Data file: c:\windows\desktop\server\2-rwcn\pirone-l\al6pyliLPA Type of Structure: Geosynthetic-Reinforced Segmental Retaining Wall Structure. Criticality: Non-critical Design Methodology: NMA Method A Wall Geometry: Design Wall Height (ft) 12.0 . Embedment Wall Height (ft) 0.58 Exposed Design Wall Height (ft) 11.42 Minimum Levelling Pad Thickness (ft) 0.5 . . . ... Number of Segmental Wall Units 18 5 Hinge Height (ft) 10.0 Base Inclination (degrees) S horizontal Wall Inclination (degrees) 7.1 Slopes: S Front Slope (degrees) S - S horizontal S Back Slope (degrees) 18.4 SRWa11 (ver 1.1 June 1995) Page 2 LN 95050839 Uniformly Distributed Surcharges: Live Load Surcharge (psf) 120 Dead Load Surcharge none Friction Cohesion Angle Unit Weight Soil Data: Soil Description: (psf) (degrees) (pcf) Reinforced Soil sand N/A 30.0 . 120.0 Retained Soil sand N/A 30.0 120.0 Levelling Pad Soil gravel N/A 40.0 125.0 Foundation Soil sand 0.0 30.0 120.0 Segmental Unit Name:. .' Default segentai unit properties.. Segmental Unit Data: ,.. 0 ..:. 'Cap Height (in) .. .. .. none 0 Unit Height (in) 8.0 Unit Width (in) . . 16.0 Unit Length (in) . 18.,0 .:,. Setback (in) . 1.0 .• . Weight (infi11ed) .(lbs) . 167.0 . . . . :Unit Weight '(infilled) (pcf) .125.3 0 . Center of Gravity (in) 8.0 Secimental Unit Interface Shear Data: Properties Peak Strength Criteria Deformation Criteria ,. . Minimum (lbs/ft) '. . 500.0 : 500.0 . . . Friction Angle (degrees) 45.0 . '45.0 .. . Maximum (lbs/ft) . 2000.0 . 2000.0 Geosynthetic Reinforcement Types and Number: Type Number Name .' 1 4 Syinpaforce FS 35 2 1 Sympaforce SF 55 . S 3 0 gympaforce SF 80 . SRWa11 (ver 1.1 June 1995) Page 3 - S LW 95050839 Geosynthetics Properties: - Strength and Polymer Type: Type 1 Type 2 Type 3 Index Tensile Strength (lbs/ft) 2627.0 3731.0 5583.0 Polymer Type polyester polyester polyester Partial Material Safety Factors: Type 1 Creep 1.59 Biological- Degradation . 1.00 Chemical Degradation 1.10 Construction Site Damage 1.15 Material Uncertainty 1.50 Long Term. Design Strength: Type 1 LTDS (lbs/ft) .. . 870.7 Coefficient of Interaction: Type 1 Peak Load Criterion. 0.72 Deformation Criterion - 0.72 Coefficient of Direct: Sliding: Peak Load Criterion Type -2 Type 3 1.59 - 1.61 1.00 . . - 1.00 1.10 - 1.10 1.08 - 1.08 1.50 1.50 Type .2 • Type 3 - 1316.8 - 1946.0 - 5 -Type 2 -Type 3 - - .0.72 • - 0.75 0:72- - -075 - -- Type 1 - - Type 2 - Type 3 . 0.75 0.8 - - 0.85 - Connection Strength: - - . Type 1 - Type. 2 - - Type 3 Peak Strength Criterion: - - - - Minimumi..-(lbs/ft) - - - 500.0 .500.0 - 500.0 - - - Friction Angle (degrees) 28.0 28.0 - - 28.0. Maximum (lbs/ft) • - • 2000.0 - 3000.0 - 3000.0 Deformation Strength Criterion: - - Minimum (lbs/ft) 500.0 500.0 - 500.0 -• Friction Angle (degrees) 28.0. - 28.0 - 28.0 Maximum (lbs/ft) 2000.0 3000.0 3000.0 .4' SRWa11 (ver 1.1 June 1995) Page 4 .I. LN 95050839 Geosynthetic-Segmental RetainingWall Unit Interface Shear Strength: Type I Type 2 Type 3 Peak Strength Criterion: Minimum (lbs/ft) . 500.0 . 500.0 500.0 Friction Angle (degrees) 27.0 .. 27.0 . 27.0 Maximum (lbs/ft) 2000.0 2000.0 2000.0 Deformation Strength Criterion: Minimum (lbs/ft) 500.0 500.0 500.0 Friction Angle (degrees) . 27.0 27.0 27.0 Maximum (lbs/ft) 2000.0 2000.0 2000.0 Coeffi.cients of Earth Pressure and Failure Plane Orientations: Reinforced Soil (Ka) Reinforced, Soil (Ka horizontal component) .. . .' 0.321 Orientation of failure plane from horizontal (degrees) 47.8. .:- Retained Soil (Ka) . 4.329 Retained Soil (Ka horizontal component)' 0.321 .., Orientation of failure plane from horizontal (degrees). 47.8 . Results of External Stability Analyses: . . Calculated Design Crite.-ia FOS Sliding . .. - 1.88 . 1.5 OK FOS Overturning . 3.67 .. 2.0. OK FOS Bearing Capacity 6.58 2.5 OK Base Reinforcement Length (L) (ft) 10.0 7.2 OK Base Eccentricity (e) (ft) . 0.65 N/A Base Reinforcement Ratio (L/H). 0.83. 0.6 OK Noté:calculated values MEET ALL design criteria. Detailed Results of External Stability Analyses:. Calculated Values: Total Horizontal Force (lbs/ft) -. 4929.9 Total Vertical Force (lbs/ft) . 16063.3 Sliding Resistance (lbs/ft) . 9274.1 Driving Moment (lbs-ft/ft) . 26161.0 Resisting Moment (lbs-ft/ft) . 96050.7 Bearing Capacity (psf) . 12977-2 Maximum Bearing Pressure (psf) 1971.9 SRWa11 (ver 1.1 June 1995) Page LN 95050839 Results of Internal Stability Analyses.: SRW Geosyn Elev Length Anchor FOS FOS FOS FOS Layer Unit Type (ft) (ft) Length Over- Pullout Pullout Sliding Spacing ft (ft) stress (peak) (def) (peak) (ft) > 1.0 > 1.0 > 1.5 N/A > 1.5 < 2.67 15 1 9.33 10.0 1.37 1.89 . 1.55 N/A 3.09 OK 11 1 6.67 10.0 3.46 1.57 4.64 N/A 2.42 OK 8 1 4.67 10.0 5.02 1.36 7.11 N/A 2.07 OK 5 1 2.67 10.0 6.58 1.34 10.84 N/A . 1.81 OK 3 2 1.33 10.0 7.62 1.43 9.77 N/A 1.74 OK Note: calculated values MEET ALL design criteria Detailed Results of Internal Stability Analyses: SRW Geosyn Elev Long Term Tensile Unit Type (ft) Design Load ft . Strength (lbs/f t) (lbs/f t) 15 1 : 9.33 . 870.7 461.8 11 1 6.67 870.7 553.8 8 1 '. 4.67 870.7 . 641.5 5 1 .. 2.67 870.7 .. 652.1 3 2 1.33 1316.8 923.7 Pullout Pullout Sliding Sliding Capacity Capacity . Force - Capacity (peak) (def) (lbs/ft) (lbs/ft) (lbs/ft) (lbs/ft) 716.4. N/A 845.6 2611:6 2567.3 N/A 1670.4 4039.4 4558.5. N/A 24687 .: 5110.3 7066.5 N/A . 3420.9 .. .6181.1 : 9026.4 N/A 4141.2 7204.1 Results of Facinci Stability Analyses: SRW Heel. Geosynthetic FOS FOS FOS FOS . FOS Unit Elev Type Over- Shear Shear . . Connection Connection V (ft) turning . (peak) (deformation) (peak) . (deformation) > 1.5 > 1.5 N/A > 1.5 N/A 18 11.33 none . 7.1 . 17.87 N/A 17 . 10.67 none 3.19 8.45 N/A - 16 10.0 none 1.95 5.42 N/A 15 9.33 1 1.36* 3.04 N/A 1.6 N/A 14 8.67 none 2.12 - N/A . - 13 .8.0 . none 2.18 - N/A 12 7.33 none . 2.04 9.35 N/A 11 6.67 1 1.85 3.28 N/A 1.76 N/A . 10 . 6.0 none . . 1.94 - N/A . .. - . . 9 5.33 none 1.91 16.77 N/A 8 4.67 1 1.83 3.73 N/A .. . 1.79 N/A 7 4.0 none 1.85 - N/A . - - 6 3.33.. none . 1.81 15.98 N/A 5 2.67 1 1.74 3.42 N/A 2.04 N/A 4 2.0 none . . 1.73 - . N/A - 3 1.33 . 2 . 1.67 4.65 N/A 1.5 N/A 2 0.67 none 1.68 - N/A 1 0.0 none 1.65 >99 N/A - - Note: * value does NOT MEET design criterion (1 occurrences) j '41 SRWa11 (ver 1.1 June 1995) Page 6 LW 95050839 Detailed Results of Facing Stability Analyses (Moment and Shear): SRW Heel Geo Drive Resist Shear Shear Shear Unit Elev Type Moment Moment Load Capacity. Capacity (ft) (lbs-ft/ft) (lbs-ft/ft) (lbs/ft) (lbs/ft) (lbs/ft) (peak) (deformation) +out -in N/A 18 11.33 none 10.5 74.2 34.2 611.3 N/A 17 10.67 none 49.4 157.7 85.5 722.7 N/A 16 10.0 none 128.3 250.5 153.9 834.0 N/A 15 9.33 1 258.5 352.6 239.5 726.9 N/A 14 8.67 none 451.4 955.1 -119.7 1056.7 N/A 13 B.O. none 718.4 1566.9 0.0 1168.0 N/A 12 7.33 none 1071.0 2188.0 136.8 1279.3 N/A 11 6.67 1 1520.5 2818.3 290.8 953.8 N/A 10 6.0 none 2078.3 4038.4 -91.9 1502.0 N/A 9 5.33 none 2755.9 5267..8 96.2 1613.3 N/A 8 4.67 1 3564.6 6506.5 301.5 1124.0 N/A 7 4.0 none 4515.8, 8334.9 -117.6 1836.0 N/A 6 3.33 none 5621.0 10172.5 121.9 1947.3 N/A 5 2.67 1 68,91.6 12019.5 378.5 1294.2 N/A 4 2.0 none 8338.9 14456.2 0.0 2000.0 .. N/A 3 1.33 2 9974.4 16688.8 290.8 . 1350.9 N/A 2 . 0.67 none 11809.4 19799.3 -325.0 ' 2000.0 N/A '1 0.0 none 13855.4 22909.7 0.0. .2000.0 . N/A : Detailed Results of Facing Stability Analyses (ConnectiOns): . . S. ' •',• SRW Heel , Geo Connection Connection. Connection Unit Elev Type Load Capacity . Capacity (ft) (lbs/ft) (peak) (deformation) (lbs/f t) (lbs/f t) N/A S 15 9.33 1 ' 461.8 736.8 ' N/A 11 6.67 1 553.8 973.6 '. N/A 8 4.67 1 641.5 1151.2 N/A 5 2.67 . 1 652.1 1328.8 N/A 1.33 2 923.7 1388.0 N/A SRWa11 (ver 1.1 June 1995) Page 7. LW 95050839 7.1 degrees 12.0 ft Sympa force FS 35 .Sympaforce FS 35 Sympaforce. FS 35 Syrapa force FS 35 0 58 ft - Sympa force SF 55 I ...• . -0.5 ft 10.0 ft . Project Identification: . Project Name: PIRINEOS POINTE CARLSBAD Section: Data Sheet: Owner: . . Client: . 0 Prepared by: RETAINING WALLS COMPANY NORTH . 0 Date: February 08 2002 Time: 10:11:05 AM Data file: . C: \windows\desktop\server\2-rwcn\pirone-1\al6sympa t .'. SRWa11' (ver. 1.1 June 1995) Page 1 LW 95050839 Licensed to: STEVE CROSBY RETAINING WALLS COMPANY . . 1531 GRAND AVENUE . AM MARCOS, CA 92069 (619) 471-2500 Licen.e Number: 95050839 Project Identification: Project Name: PIRINEOS POINTE CARLSBAD Section: Data Sheet: Owner: Client: 'Prepared by: RETAINING WALLS COMPANY NORTH Date: February 08 2002 Time: 10:11:05AM Data file: c:\srwall1\al6sympa .'.Type ofStructutë:. ......'Ge öynthetic-Reinfrced Se' eñál Retaining "Wall Structure Criticality.., Non-critical . . . ... . Design' Methodology: NCMA Method A . . •' Wall Geometr Design Wall Height •(ft) 13.33 Embedment Wall Height (ft) 0.64 Exposed Design Wall Height (ft) • • 12.69 Minimum Levelling Pad Thickness (ft) 0.5 Number of Segmental Wall Units 20 Hinge Height (ft) 10.0 Base Inclination (degrees) horizontal Wall Inclination (degrees) 7.1 Slopes: Front Slope (degrees) , horizontal Back Slope (degrees) • • 18.4 SRWa11 (ver 1.1 June 1995)' Uniformly Distributed Surcharges: Live Load Surcharge (psf) Dead Load Surcharge (psf) Soil Data:: Soil Description: Reinforced Soil sand,. Retained Soil sand: Levelling Pad Soil grave]. Foundation' Soil sand Page 2 LN 95050839 120 258 D Friction Cohesion AngJe Unit Weight (psf) , (degrees)' (pcf),, N/A 30.0 ' 120.0 N/A "30.0 , ' ' 120.0:', N/A ., 40.0 1 125.0' 0.0 ' 30.0 , ' " 120;0 Segmental Unit Name: Default segmental unit properties Segmental Unit Data: Cap Height (in) - , none , V. Unit Height (in) ' '8.0 V ,, Unit Width (in) 16.0 Unit Length (in) 18.0' Setback (in) ' 1.0 Weight (infilled) (lbs) 167,. 0 Unit Weight (infilled) (pcf) 125.3 • V Center of Gravity (in) 8.'0- Segmental Unit Interface Shear Data: Properties ' - ' Peak Strength Criteria Deformation Criteria Minimum (lbs/ft) 500.0 500.0 Friction Angle (degrees) 45.0 45.0 Maximum (lbs/ft) 2000.0 • 2000.0 Geosynthetic Reinforcement TvDes and Number: Type Number Name 1 3 • Sympaforce FS 35 2 3 Sympaforce SF 55 3 ' 0 Sympaforce SF 80 SRWa11 (ver 1.1 June 1995) Page 4 LW 95050839 Geosynthetic-Segmental Retaining.Wa1l Unit Interface Shear Strength: Type 1 Type 2 Type 3 Peak Strength Criterion: Minimum (lbs/ft) 500.0 500.0 500.0 Friction Angle (degrees) 27.0 27.0 27.0 Maximum (lbs/ft) . 2000.0 2000.0 2000.0 Deformation Strength Criterion: Minimum (lbs/ft) . 500.0 500.0 . 500.0 Friction Angle (degrees) 27.0 27.0 27.0 Maximum.(ibs/ft) 2000.0 2000.0 2000.0 Coefficients of Earth Pressure and Failure Plane Orientations: Reinforced Soil (Ka) . . 0.329 Reinforced Soil (Ka horizontal component) 0.321 . Orientation of failure plane from horizontal (degrees) 47.8 Retained Soil (Ka) 0.329 Retained Soil -(Ka horizontal component) . 0.321 Orientation of failure plane from horizontal (degrees) 47.8 Results of External Stability Analyses: . . . . . - . Calculated Design Criteria FOS Sliding . •' ... . 1.79 . 1,.5 OK FOS. Overturning . . 3.42 2.0 OK FOS Bearing Capacity :• 596, : - 2.5 OK Base Reinforcemént.Length (L) (ft) 11.5 .. . 8.0- OK BaseEccéntricity (e) (ft) 0.77 . N/A Base Reinforcement Ratio (L/H) 0.86 0.6 OK Note: calculated values MEET ALL design criteria Detailed Results of External Stability Analyses Total Horizontal Force 'lbs/ft) Total Vertical Force (lbs/ft) Sliding Resistance (lbs/ft) Driving Moment (lbs-ft/ft) Resisting Moment •(lbs-ft/ft) Bearing Capacity (psf) Maximum Bearing Pressure (psf) Calculated Values: 7538.1 23 d22. 7 13523.1 48206.7 164752.4 14789.4 24:32.7 SRWa11 (ver 1.1 June 1995) Licensed to: STEVE CROSBY RETAINING WALLS COMPANY 1531 GRAND AVENUE SAN MARCOS, CA 92069 (619) 471-2500 License Number: 95050839 Project Identification: Project Name: PIRINEOS.OINTE CARLSBAD Section: Data Sheet: Owner: Client: Prepared by:. RETAINING WALLS COMPANY NORTH Date: February 08 2002 Time: 10:11:05 AN Page 1 LN 95050839 (1RMl\L 5TJtr1 Data file: c:\srwalll\al6sympa .. Ty of Structure: . . . Geosthetic-Reinforced Segmental Retaining. Wall Structure Criticality: Non-critical Design Methodology: NCMA Method A . .. .. Wall Geometr Design Wall Height (ft) 13.33 Embedment Wall Height (ft) . 0.64 Exposed -Design Wail Height (ft) 12.69 . Minimum Levelling Pad Thickness (ft) 0.5 Number of Segmental Wall Units 20 Hinge Height (ft) . 10.0 Base Inclination (degrees) horizontal Wall Inclination (degrees) 7,.l Slopes: Front Slope (degrees) horizontal Back Slope (degrees) - 18.4 1' SRWa11 (ver 1.1 June 1995) : Page 2 LW 95050839 Uniformly Distributed Surcharges: Live Load Surcharge (psf) 120 Dead Load Surcharge none Friction •. Cohesion Angle Unit Weight Soil Data: Soil Description: (psf) (degrees) (pcf). Reinfórced,Soil sand N/A 30.0 120.0 Retained -Soil sand N/A 30.0 120.0 Levelling Pad 'Soil gravel N/A 40.0 Foundation Soil sand. 0.0 •. 30.0 ... 120.0 Segmental Unit Name: Default segmental unit properties Segmental Unit Data:. . •• Cap Height .(.in) none Unit 'Height (in) : : 8.0 S.. Unit Width (in) 16.0 Unit Length (in) 18.0 Setback (in) • 1.0 .' S • Weight (infilled) (Ths) 167.0 Unit Weight (infi.11ed) (.pcf) 125.3 • • S Center of Gravity' (in) 8.0 .• S Segmental Unit Interface Shear Data Propertieà Peak Strength Criteria Deformation Criteria Minimum (lbs/ft) 500.0 0500.0 Friction Angle (degrees) 45.0 45.0 Maximum (lbs/ft) 2000.0 2000.0 Geosvnthetic Reinforcement Tvoes and Number: Type. Number Name 1 3 Sympaforce FS 35 2 '3 Sympa-force SF 55 3 ,0 Sympaforce SF 80 613 SRWa11 (ver 1.1 June 1995) Page. 3 LN 95050839 Geosynthetics Properties: Strength and Polymer Type: Type 1 Type 2 Type 3 Index Tensile Strength ('lbs/ft) 2627.0 373i.0 5583.0 Polymer Type polyester polyester polyester Partial Material Safety Factors: Type 1 Type 2, Tye 3 Creep 159 159 161 Biological Degradation 1.00 1.00 1.00 Chemical Degradation 1.10 1.10 1.10 : Construction Site Damage 1.15 1.08 1.08 Material-,Uncertainty .. 1.50 , 1.50 . 1.50 Long Term Design Strength: Type 1 Type 2 Type 3 LTDS (lbs/ft) •, : 870.7 . 1316.8 1946.0 Coefficient of Interaction: Type 1 Type 2 Type 3 Peak Load Criterion 0.72 0.72 0.75 . . Deformation Criterion . 0.72 . 0.. 72 . 0.75. Coefficient of Direct Sliding Type 1 Type 2 Type 3 Peak Load Criterion. •.. . 0.75 0.8 . 0.85" ' Connection Strength: . Type 1 Type 2 Type 3 Peak Strength Criterion: Minimum (lbs/ft) 500.0 500.0 . 500.0 Friction Angle (degrees) 28.0 28.0 28.0 Maximurn'(lbs/ft) . 2000.0 3000.0 3000.0 Deformation Strength Criterion: - • Minimum (lbs/ft) ' - 500.0 500.0 500.0 Friction Angle (degrees) 28.0 28.0 28.0. Maximum (lbs/ft) • 2000.0 3000.0 3000.0 or SRWa11' (ver 1.1 June 1995) Geosynthetic-Segmental Retaining Wall Unit Interface Shear Strength: Type 1 Peak Strength Criterion: Minimum (lbs/ft) 500.0 Friction Angle (degrees) 27.0 Maximum (lbs/ft) 2000.0 Deformation Strength Criterion: 575 Page 4 LN 95050839 Type 2 Type' 3 500.0 500.0 27.0 27.0 2000.0 2000.0 Minimum :(1b5/ft) ' " ' ' 500.0 500.0 500.0 Friction Angle (degrees) , ' 27.0 27.0 27.0 Maximum (lbs/ft) ', . 2000.0 2000.0 .. .2000.0 Coefficients of Earth Pressure and Failure Plane Orientations Reinforced Soil (Ka) 0.329 Reinforced Soil (Ka horizontal component) ' :. 0.321 Orientation of failure plane from horizontal (degrees), 47.8, Retained Soil (Ka) ' , '0.329 Retained Soil (Kahorizorital component') . ' 0.321 Orientation of failure plane from horizontal (degrees)'.' 47.8. ' Design Criteria 1.5 OK 2.00K 2.5 OK 8.0 OK N/A 0.60K Result's of External Stability Analyses:' Calculated FOSSiiding. ' ' ' 1.94 FOS Overturning . ' 3.9 FOS Bearing 'Capacity '.' 7.05 Base Reinforcement Length (L), (ft) 11.5. Base. Eccentricity. ,(e) (ft)' 0. 64. Base Reinforcemerit'Ra'tio (L/H) 0.86 Note: calculated values MEET ALL design criteria Detailed Results of External Stability Analyses: Calculated Value.: Total Horizontal Force lbs/ft) 6140.4 Total Vertical Force (lbs/ft) 20663.5 Sliding Resistance (lbs/ft) 11930.1 Driving Moment (lbs-ft/ft) 36402.5 Resisting Moment. (lbs-ft/ft) 141950.0 Bearing Capacity (psf) 15144.7 Maximum Bearing Pressure (psf) 2148.3 Page 5 LIV 95050839 FOS FOS Pullout Pullout (peak) (def) > 1.5' ' N/A 2.24 N/A 5.55 N/A 8.11 N/A 9.88 N/A 14.12 N/A 19.16 ' N/A FOS ' Layer Sliding Spacing (peak) (it) >'.1.5 < 2.67 3.12 OK 2.53 OK 2.2 OK 2.05 OK 1.81 OK 1.67 OK" Pullout, ,Sliding Capacity Force (def) (lbs/it) (lbs/it) N/A , - 985.1 N/A ' 1863.4 N/A 2701.7 , N/A , 3694.0 N/A 4840.2 N/A 5689.9 Pullout Capacity (peak) (lbs/it) 1032.7 3072:5 5205.3 7854.9 11021.4 13435.5 Sliding Capacity (lbs/it) 3075.4 4711.0 5937.7 7555.8 8739.5 9490.8 SRWa11 (ver 1..1 June 1995) Results of Internal Stability Analyses: SRW Geosyn Elev Length Anchor FOS Unit Type (it) (ft. Length Over- (ft) stress >'10 > 1.0 17 1 10.67 11.5 '- 1.83 1.89 13 1 8.0 11.5 3.91 1.57 10 1 6.0 11.5 5.48 1.36 7. 2 4.0 11.5 7.04 1.66 4 . 2 •. 2.0 11.5 8.6 1.69 2 2 0.67', 11.5 9.65 1.88 Note: calculated values MEET ALL design criteria Detailed Results of Internal Stability Analyses: SRW Géosyn Elev: . Long Term Tensile Unit Type . (ft) Design . Load Strength . (lbs/f t) (lbs/it) 17 1 10.67 870.7. . '461.8 13 1.. 8.0,..' 870.7 .: 553.8 10 1.' 6.0: 870.7 . 641.5 7. 2.,. 4.0': 1316.8 .. 795.4 .4 . '2. 2.0.. 1316.8.- . 780.4 2, 2. 0.67: '. 1316.8 . 701.3 Results of Facing Stability Analyses: . • • SRW Heel Geosynthetic.' FOS FOS FOS FOS - FOS Unit Elev T'pe. . , Over- Shear Shear Connection Connection (it) . , • , , '. turning (peak) '(deformation) (peak) . .(deformation) -: > 1.5 > 1.5 N/A > 1.5 'N/A '20 12.67 none' 7.1 17.87 N/A 19 12:0 none . 3.19 8.45 N/A 18 11.33 none • . 1.95 5.42 N/A 17 10.67 • 1 ' . 1.36* 3.04 N/A 1.6 N/A 16 10.0 none 2.12 - N/A' - - 15 9.33 none 2.18 - N/A - - 14 8.67 none . 2.04 9.35 N/A - 13 8.0 1 ' 1.85 3.28 N/A 1.76 • N/A 12 7.33 none 1.94 - N/A - - - 11 6.67 none 1.91 16.77 N/A - - 10 6.0 1 • 1.83 3.73 N/A • 1.79 N/A 9 5.33 none 1.85 - N/A : • - • 8 4.67 none 1.81 15.98 N/A - - 7 4.0' 2 • 1.74 , 3.42 N/A , 1.67 N/A 6 3.33 none . 1.77 -• N/A - - 5 2.67 none . 1.73 13.56 N/A . ' - - 4 2.0 2 • 1.68 2.97 N/A 1.78 ' N/A 3 1.33 none ' 1.68 >99 N/A 2 0.67 2 1.65 3.95 N/A 1.98 N/A 1 0.0 none 1.66 - N/A - - Note: * value does NOT MEET design criterion (1 occurrences) SRWa11 (ver 1.1 June 1995) Page 6 LN 95050839 . Detailed Results of Facing Stability Analyses (Moment and Shear): SRW Heel Geo Drive Resist Shear Shear Shear Unit Elev Type Moment Moment Load Capacity Capacity (ft) (lbs-ft/ft) (lbs -ft/ft) (lbs/ft) (lbs/ft) (lbs/ft) (peak) (deformation) #out -in N/A 20 12.67 none 10.5 74.2 34.2 611.3 N/A 19 ' 12.0 none 49.4 157.7 85.5. 722.7. N/A .18 . 11.33 none 128.3 250.5 ' 153.9 834.0 N/A 17 10 67 1 '258..S. 352.6 239.5 726.9 N/A S 16 10..O none 451.4 955.1 -119.7 1056.7 - N/A 15 9.33 none 718.4 1566.9 0.0 1168.0 N/A 14... 8.67 none 1071.0 2188.0 .136.8 .1279.3 N/A 13 8.0 1 1520.5 2818.3 290:8 953.8 N/A 12 7.33 ....none. 2078.3 4038.4 . .. 91.9 ''1502.0' N/A . 11 6.67 none 2755.9 .. 5267.8 . 96.2 . 1613.3 N/A ,. ....................... .1 ... . 364.6 65065 ' 015 •. 11240 N/A 9 . . 5.33 none , 4515.8 8334.9 : -117.6 1836.0 N/A 8, . 4.67 none 5621.0 10172.5 .121.9 1947.3 N/A . 7 4.0. 2 .... 6891.6 12019.5 378.5 1294.2 N/A 6 3.33 none • 8338.9 . 14753.6 ' -143.3 2000.0 N/A 5 2.67 none 9974.4 17283.6 . 147.5 2000.0 N/A 4 2.0 2 11809.4 19813.6 455.4 1350.9 N/A 3 1.33 none 13855.4 23221.5 0.0 • 2000.0 N/A 2 . 0.67 2 •., 16123.8 26629.3 . 342.1 1350.9 N/A 1 0.0 .. none 18625.9 30915.0 : 0.0 2000.0 N/A Detailed Results of Facing Stability Analyses (Connections): • . SRW Heel . Geo Connection Connection ' Connection Unit •. Elev Type Load Capacity Capacity . (ft) . (lbs/ft) (peak) (deforma tion) (lbs/ft) (lbs/ft) N/A • • 0 17 ...... 10.67 1 . 461.8 736.8 • N/A •. 0 13 8.0 1 553.8 973.6 'N/A . . 10 • 6.0 . 1 641.5 1151.2 N/A . 7 4.0 2 795.4 . 1328.8 N/A . . 4 , .. 2.0 2 780.4 1388.0 N/A 2 0.67 2 701.3 1388.0 N/A . SRWa11 (ver 1.1 June 1995) Page 7 LN 95050839 7.1 degrees 13.33 ft SympaforceFS 35 Syinpa force FS 35. .. : •. SyrnpaforceFS 3 I . I-------- - Sympa force SF 55 Sympaforce SF 55 0.64 ft. . . SythpS force SF 55 0 1 . -05 ft H . 11.5 ft . . . Project 'Identification: Project Name: PIRINEOS POINTE CARLSBAD Section: • ... Data Sheet: • Owner: . Client: Prepared by: RETAINING WALLS COMPANY NORTH Date: February 08 2002 Time: 10:11:05 AM Data file: c:\srwa111\a16sympa 0 4 SURCHARGE PERCENTAGE CALCULATION Angle of Internal Friction 30 deg a 60 deg . . .'.. . s Wall Slope Distance Geogrid . Dead For External Stability Fo.tematStability Height . Height to Surch. Length . •. Load (L+ X) <J L+.5X <J <(L+ X) J <(L+.5X) L < J .3L < J < L J <(L+.5X) H h J L X 0.3 L L+ 0.5X L+ X . Surcharge q . q ... .. q q' q q ft ft ft ft . ft ft ft. . . ft psf psf . psf psf psf psf . psf 2.67 1.60 6.60 0.00 2.47 0.00 : 1.23 2.47 120 0 na •. na 0 0 na 4.00 1.60 6.60 4.50 . 3.23 1.35. 6.12 7.73 120 na 42 . na 0 0 na 6.67 1.60 6.60 6.50 4.77 1.95 .8.89 11.27 120 na . na . 120, 0 0 na. 8.00 1.60 6.60 7.50 5.54 2.25 10.27 13.04 120 na • na . • 120 . na 14 • na 10.00 1.60 6.60 9.00 6.70 2.70 .12.35 . 15.70 120 na na . 120 na . 32 na 12.00 1.60 . 6.60 10.00 7.85 3.00 .13.93 17.85 120 na na 120 na 41 na 13.33 1.60 6.60 11.50 8.62 3.45 15.81 . 20.12 120 'na . na 120 na 51 na Wall Slope Distance Geogrid . .. Dead • . . For External Stability . For-ExteTTIl Stability Height Height to Surch. Length . Load (L+ X) <J L+.5X J < (L+ X) J <(L+.5X) L < J .3L < J <L J <(L+.5X) H h J L X . 0.3 L L+ 0.5X L+ X Surcharge q . q q q q q ft ft ft ft ft ft . ft ft psf pf psf psf psf psf psf 2.67 1.60 16.40 0.00 2.47 . 0.00 1.23 2.47 600 0 • na na , 0 0 na 4.00 1.60 16.40 4.50 ..3.23 " 1.35 6.12 7.73 .. 600 0 na . • na 0 0 na 6.67 1.60 16.40 6.50 4.77 1.95 8.89 11.27 600 0 na • na 0 0 na 8.00 .1.60 16.40 7.50 5.54 2.25 10:27 13.04 600 0 na na 0 0 na 10.00 1.60 16:40 9.00 6.70 2.70 12.35 15.70 600.. . 0... na • na 0 . 0 na 12.00 1.60. 16.40 10.00 7.85 3.00 .13.93: .. 17.85 600 na . 1.11 na . 10 . 0 na 13.33 1.60 16.40 11.50 8.62 3.45 15'.81 20.12 600. na . 259' n• . . 0 0 na SECOND EDITION NATIONAL fl CONCRETE MASONRY C ASSOCIATION 2302 Horse Pen Road Herndon, Virginia 20171-3499 (703) 713-1900 Segmental, Retaining Walls TO DETERMINE APPROXIMATE SURCHARGE OF UPPER WALL 2 ON LOWER WALL 1' IMPLEMENT BY ITERATIVE PROCESS 1. ESTIMATE BASE LENGTH L11 AND CALCULATE EXTERNAL FAILURE. ANGLE, 2..CALCULATE AND dl BASED UPON L1 3. CALCULATE ACTUAL L1 BASED UPON EXTERNAL STABILITY ANALYSIS USING q , AND . FROM STEP 2 •..•• . - dl 4. IF. CALCULATED L (STEP 3). < ESTIMATED Li (STEP 1)... OK. iF NOT REPEAT STEPS 1-4 5 CHECK GLOBAL/OVERALL STABILITY OF FINAL GEOMETRIC CONFIGURATION J = HORIZONTAL DISTANCE FROM WALL FACE TO WALL FACE L:= BASE LENGTH OF GEOSYNTHETIC REINFORCEMENT FOR SOIL REINFORCED SRWs AND BASE WICTH OF .1. CONVENTIONAL . SRWs 11iq2 'I... I:.,. (.s \ '.:•• a.(1)= SEE EQ. 3-14 . 0ç.. X, (1-11 + d/S)/TAN cX(1) S = 500 FOR FLAT (LEVEL) BACKFILL BETWEEN WALLS FOR INTERNAL STABILITY WALL 1 WHEN . J,> L . NO INFLUENCE, qd=. 0 q Q. .3L1 < J. < LI USE PERCENTAGE OF SURCHARGE q j) ( '2) H') . — (L - J) (q ) di •..'L1 .2 .• q 1 L 12. J < .3 L USE FULL SURCHARGE. . . . q , Z(2) H q 1 = q . FOR EXTERNAL STABILITY WALL 1: . . . .. WHEN . J > (L1+ X1 ) NO INFLUENCE, id 0 •q1 = 0 (L1 + .5X1 )< J <.' (L1+ x0 • • USE PERCENTAGE OF SURCHARGE . (Lii- X 1 — J)((2).r2 ) q= (L1 + X1 — J)(q dl ) J < (1-1+.5X) - USE FULL 'SURCHARGE q dl Z2). H q1 = q 22 NOTE: .311 AND .5X1 ARE ARBITRARY BUT EMPIRICALLY BASED GEOMETRIC LIMITS TO ENSURE A CONSERVATIVE SURCHARGE APPROXIMATION FIGURE 2-11: • SURCHARGE APPROXIMATION FOR TIERED WALLS • AJP r1 cM \N* . I — , . . r # i •)- i NOTE: H1 MUST H1 I I I April 26, 2002 BARRY AND ASSOCIATES GEO TECHNICAL ENGINEERING P.O. Box 230348 Encinitas, CA 92023-0348 (760) 753-9940 I Darryl Clubb. Coast Contracting 7929 Silverton Avenue, Suite 609 San Diego, California 92126 I Subject: GRADING REPORT, RETAINING WALL BACKFILL Proposed Multi-Unit Development North Side of Pirineos Way I Carlsbad, California 92009 APN 216-200-2400 I References: 1. Keystone Retaining Wall Footing Inspection Pirineos Pointe Pirineos Way Carlsbad, California I 2. Grading Plan Prepared by Engineering Design Group Dear Mr. Clubb In response to your request, we have observed the grading operation I and performed field density tests during the backfilling for the subject retaining wall. The results of our density testing and laboratory testing are presented in this.report. I Based on the results of our testing, it is our opinion that the fill was placed in an adequate manner and compacted to a minimum of 90 percent of the laboratory maximum dry density. If you have any questions, please contact us at 760.753.9940. I Respectfully submitted, A.R. B SSQCI A.:, Barry, G oi 19 Principal Engineer EXP. cHsIG CALIF 131106 GRADING REPORT, RETAINING WALL BACKFILL Proposed Multi-Unit Development North Side of Pirineos Way Carlsbad, California 92009 APN 216-200-2400 Prepared For Darryl Clubb Coast Contracting 7929 Silverton Avenue, Suite 609 San Diego, California 92126 April 22, 2002 W.O. G-1706 Prepared by: BARRY AND ASSOCIATES P.O. Box 230348 Encinitas, California 92023-0348 April 26, 2002 W.O.# G-1706 Page 1 I S I INTRODUCTION This report presents the results of our observations and field density testing for the A-16 Retaining Wall, by Retaining Wall Company North. Basically the project consisted of excavation to the I bottom of the slope, preparation for the base of the wall and I installing the drainage system (see reference #1, letter dated March 20, 2002) A Proctor test was performed with a mixture of the on-site soils. I Density tests were conducted every 2 vertical feet of compacted fill. Fill soil was placed in lifts of approximately 6.0 to 8.0 I inches thick. The soil was moistened as required to achieve optimum moisture content, and compacted with a vibratory roller. I The fill was placed to a minimum of 90 percent of the maximum I dry density, as indicated by our test results. The results of our density testing are presented on Table 1. LABORATORY TEST DATA The laboratory standard for determining the maximum dry density was I performed in accordance with ASTM D 1557-92. Field density tests I were performed in accordance with ASTM D 1556. The results of the laboratory maximum dry density, for the soil used as compacted fill on the site, is summarized below: April 26, 2002 W.O.# G-1706 Page 2 Maximum Dry Density Optimum Description (p.c.f.) Moisture (%) Brown sandy clay 127 .5 10.5 LIMITATIONS This firm assumes no responsibility for any alterations made without our knowledge and written approval to the slope or pad grade on the property, subsequent to the issuance of this report. If you have any questions, please do not hesitate to contact us at (7 60) 753-9940. Respectfully submitted A. RBRY- ASSO A.R. Bafry.-' Principal Eng W.O. # G-1706 Pirineos Way Carlsbad, California APPENDIX "A" LABORATORY TEST RESULTS TABLE I Field Dry Density and Moisture Content Above Moisture Dry Relative Test Test Wall Base Content Density No. Location Elev. % .JpcfJ Compaction 1. See Plan 2' 10.3 114.8 90 2. See Plan 2' 11.1 117.0 92 3. See Plan 4' 10.8 114.9 90 4. See Plan 4' 10.4 115.2 90 5. See Plan 6' 10.5 115.8 ' 91 6. See Plan 6' 10.5 116.1 91 7. See Plan 8' 9.1 117.5 92 8. See Plan 8' 10.5 '116.1 91 9. See Plan 10' 9.6 ' 117.0 ' ' 92 10. See Plan 10' 11.2 115.1 90 11. See Plan 12' 12.3 116.0 91 12. See Plan 12' 12.1 116.3 91 MINIMUM 2% SLOPES TO DRAIN INLETS SOIL 90% RELATIVE BACKFILL COMPACTlON CWACTED TO I I If34 d i 1 0 0'-r I 4 BUILDING LINE --------------------r--------A I ... DRAIN PIPE [SMOOTH WALL I PERCENT^ SLOPE TO SUl TABLE OUTLET AND DIAMETER PER PLANS. TYPICAL AREA DRAIN DETAIL NO SCALE L~~~~~~~~ PAVING 1P.C.C.I 3000 PSI CONCRETE WITH NO SPEC1 AL INSPECTI ON No. 5 BAR CONTINUOUS WiTH 30 BAR DIAMETER LAP MINIM 121 TYP I CAL SWAL E DETA I L NO SCALE STREET RIGHT OF WAY = 56'-0' -----I SIDEWALK TYPICAL STREET SEC1 ;ON PlRlNEOS WAY NO SCALE -EXISTING CURB -2&% 78.26FS VERTICAL CURVE AT GRADE BREAK DRIVEWAY SECT ION NO SCALE TlNG 24" R.C.P. STORM N PIPE PER C!TY OF SBAD DRAWIIIG NO. 169- 1 NOTE: RETAINING WALL DESIGN TO BE PROVIDED BY OTHERS UNDER SEPARATE PEW1 T EXiSTlNG WATER LATERAL TO BE ABANDONED ~WG 395-6 STA 2t58.15 C/L OF 24' D/W PER G- 14 AND GS-12 EX1 ST t NG SMR LATERAL TO BE ABANDONED NOTE: RETAINING WALL FOOTINGS TO W INTA I N THE PROPER D l STANCE TO DA'V'L 1 GUT AS RECOMENDED IN THE PROJECT SO ILS REPORT. I EXISTING FIRE/ HYDRANT PROPOSED STOW DRAIN CLEANOUT----I PER DW 395-6 GRADINC PLAN SCALE: 1" - 20' "AS BUILT" NOTE: IN THE EVENT OF A STORM PRIOR TO STORM DRAIN INSTALLATION, CONTRACTOR TO PROVIDE PW TO REMOVE ANY WATER COLLECTED ON-SI TE. RCE EXP. DATE REVIEWED BY: SCALE I" = 20 FT PROJECT NOTES: 1. PROPOSED RETA IN1 NG WALLS STRUCTURAL DES 1 GN TO BE PER THE RECOhMENDATIONS OF THE PROJECT SOILS ENGINEER AS OUTttNED IN THE SOILS REPORT. 2. GUTTERS TO BE ADDED TO RESIDENCE AND Tl GHTL !NED 1 NTO PROPOSED DRAINAGE SYSTEM. 3. REPRESENTATIVE OF EDG TO OBSERVE DRAINAGE SYSTEM PRIOR TO BACKFILL 1 NG. 4. ALL FILL AND WALL BACKFILL TO BE COMPACTED TO 90% RELATIVE COMPACTION. 5. DRAINAGE TO SLOPE AT 2% MlMlMUM AWAY FROM RESIDENCE FOR A MINIMUM OF 5 ' . 6. DO NOT CONNECT FRENCH DRAIN SYSTEM TO AREA DRAIN SYSTEM DENSI'. - - I INSPECTDR DATE I - WATER OUAt t T Y NOTE; THE OWNER SHALL BE RESPONSIBLE TO PERFORM REGULAR MAINTENANCE ON STORM WATER QUALITY DEVI CES TO ENSURE THE I R EFFECT1 VENESS, ALL INLETS LOCATED WlTHiN PAVED AREAS SHALL BE F I TTED Wl TH A FOSS I L F I L TER OR EQUAL. 11 CITY OF CARLSBAD Im 1 " I I ENGINEERING DEPARTMENT IW ~GRADWG PLANS FOR: I PIRINEOS POINTE PIIUNEOS WAY CARLSBAD, CA PLANS PREPARED BY: - - 1 ENGINEERING DESlGN GROUP ctr/ DATE I A 1 I I I 2/21 MONTIEL ROAD I LU I DAK I INITIAL DATE ] INITIAL DATE i 1 Dm BY: -1 I PROJECT NO. I c-Z I SAN MARCOS, CA REVISION DESCRIPTION . CHKD BY: - OM APPROVAL CIlY APPROVAL RVWD BY: - SOP 00-16 Mati Q202 05:49p BARRY AND ASSOCIATES GEOTECHNICA L ENGINEERING P.O. Box 230348 Encinitas, CA 92023-0348 (760) 753-9940 March 20, 2002 Darryl C1.ubb Coast Contracting 7929 Silverton 'Avenue, Suite 609 San Diego,' California 92126 Att: Mr. Torn Rice Subject: KEYSTONE RETAINING WALL FOOTING INSPECTION PIRINEOS POINT! PIRINEOS WAY CARLSBAD', CALPORNI Reference: Grading Plen Prepared by Engineering DesigrtGroup" Dear Mr. Clubb In response to your request, we have inspected the excavation in preparation for the Keystone retaining at the subject site. The bottom of the footing excavation was in3pected on March 20, 2002. The bottom of the footing excavation was probed with a steel probe and determined to be adequate for the proposed retaining wall. The depth and width of the footing excavation are in accordance with the approved plan and the Keystone calcilation sheets for the referenced site. If you have any questions, please contact us at 760.153.9940. Respectfully submitted, A.R. BARRY,4M ASSOCIATES ry, Principal Engine r Copy, Inspecto*, city of Mas 02 02 05:49p I BARRY AND ASSOCIATES GEO TECHNICAL ENGINEERING P.O. Box 230348 Encinitas, CA 92023-0348 (760) 753-9940 March 20, 2002 Darryl Clubb Coast Contracting 7929 •Sjlverton Avenue, suite 609 San Diego, California 92126 Att: Mr. Tom Rice Subject: KEYSTONE RETAINING WALL FOOTING INSPECTION PIRINEOS POINT! PIRINEOS WAY CARLSBAD, CALIFORNIA Reference: Grading Plan Prepared by Engineering Design Group Dear Mr. Clubb In response to your request, we have inspected the excavation in preparation for the Keystone retaining at the subject site. The bottom of the footing excavation was inspected on March 20, 2002. The bottom of the footing excavation was probed with a steel probe and determined to be adequate for the proposed retaining wall. The depth and width of the tooting excavation are in accordance with the approved plan and the Keystone calculation sheets for the referenced site. If you have any questions, please contact us at 760.753.9940. Respectfully submitted, R. A.R. BARRY ASSOCIATES ry, . R% E. 3I3I/O Principal Engine r AP I - '0FCA' Copy, Inspecto, city of Carl BARRY AND ASSOCIATES GEOTECHNICAL ENGINEERING P.O. Box 230348 Encinitas, CA 92023-0348 (760) 753-9940 May 30, 2002 Darryl Clubb Coast Contracting 7929 Silverton Avenue, Suite 609 San Diego, California 92126 Subject: Observations of A-16 Retaining Wall Construction PIRINEOS POINTE PIRINEOS WAY CARLSBAD, CALIFORNIA Reference: Grading Plan Prepared by Engineering Design Group Dear Mr. Clubb, A soil sample was collected for a direct shear test. The results of the test show that the residual shear (Remolded) to 90% of the maximum density was 31.3 degrees. The length of the geogrid placed behind the wall is a minimum of 10' measured from the inside face of the wall. The vertical spacing of the geogrid behind the wall is in conformance with the wall calculations. The temporary backcut excavation facilitated the 10' length of geogrid The foundation excavation prior to the wall construction was probed and found satisfactory. Wall drainage system was observed prior to wall construction and determined adequate. Soil density tests were performed every 2 vertical feet and found to be a minimum of 90% of the maximum density. Heavy equipment (vibratory roller kept a minimum of 3' from the wall. May 30, 2002 W.O.#G-1706 Page 2 If you have any questions, please contact us at 760.753.9940. Respectfully subm ABAR AP 20B~arfl, Principal Engiij rK. 300119 Exp. 3/31106 J h Copy, Inspector, sbad P .1 2-C) 6114Y /,, 911o, w - oq / L 31)-( ox - Ell at4t/4 PCR02086 2614 PIRINEOS WY CBAD PIRINEOS POINTE-CHASNGE FROM KEYSTONE TO A-16 RETAIN WALL SYSTEM PCR Lot#: DARRYL CLUBB