Loading...
HomeMy WebLinkAbout2618 CAZADERO DR; ; CB100243; Permit02-26-2010 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Electrical Permit Permit No: CB100243 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Reference #: PC#: Project Title: 2618 CAZADERO DR CBAD ELEC 2152903400 Lot#: WOITH RES INSTALL ROOF MOUNT PHOTOVOLTAIC SYSTEM Status: ISSUED Applied: 02/09/2010 Entered By: KG Plan Approved: 02/26/2010 Issued: 02/26/2010 Inspect Area: Applicant: WEST COAST APPLIANCES SUITE B 10728 PROSPECT AV 92071 619-557-0446 Owner: WOITH KEITH E&KATHRYN A 2618CAZADERO DR CARLSBAD CA 92009 Electric Issue Fee Single Phase per AMP Three Phase per AMP Three Phase 480 Per AMP Remodel/Alteration per AMP Remodel Fee Temporary Service Fee Test Meter Fee Other Electrical Fees Additional Fees TOTAL PERMIT FEES 0 0 0 0 $10.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $110.00 $0.00 $120.00 Total Fees:$120.00 Total Payments To Date:$120.00 Balance Due:$0,00 BUILDING PLANS -'^ V>:H{.AGEA*'.ACHED Inspector: FINAL APPROVAL Date: ° >Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. w * Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-27 17/2718/2719 I"" A D 1 C R A P^ Fax 76°-602-8558 V. r\ r\ L *3 D/ \ L * www.carlsbadca.gov ' JOB ADDRESS • CT/PHOJECT ft "" '" LOT* PHASES tt OF UNITS ff BEDROOMS" SUITES/SPACES/UNIT* Plan Check NoL;^/£/_t/X_y. ^> Est. Value Plan Ck. Deposit $$ ^ / APN .^1 #BATH"ROOMS TF'NANT BUSINESS NAME CONSTR. TYPE oc&^Gpoup . !| DESCRIPTION OF WORK: Include Square Feetof AffectedArea(s) ±5TEP EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF)FIREPLACE N0| | AIR CONDITIONING FIRE SPRINKLERS YES I I NO] I CONTACT NAME (If Different Fom Applicant) 'ADDRESS | CITY !" PHONE" "" EMAIL "~ " '" " " "" ZIP ADDRESS PHONE EMAIL " 7/1* S^652 STATE FAX 5gmaii.com PROPERTY OWNER NAME I iADDRESS fCITY ~ 2618CAZAE PHONE 619-851-1471 STATE ZIP r~* AoA FMAIL ARCH/DESIQNrR NAME & ADDRESS ADDRESS CITY PHONE EMAIL S1ArEl.IC.ff AVE #6 STATE CA rtiiheal^o&mail.com CLASS C10 C20 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires theapplicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9. commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to acivil penalty of not more than five hundred dollars ($500)). Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations: I | f have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. L*_l I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co . . ENDURANCE WORKERS COMPENSATION Policy No. ^wBWMiMSMi Expiration Date iwaio This section need not be completed if the permit is for one hundred dollars ($100) or less. I I Certificate of Exemption: I certify that in the performance of the work for which thjxjSrrnlTis issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is/rfrrawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,0001. in addition to the cost of compensation, damages as Piayiderrfa^in Secua>»37()6 of the Labor code, interest and attorney's fees. D AGENT DATE Q£^ &-*? ~ /O£$ CONTRACTOR SIGNATURE I hereby affirm that I am exempt from Contractor's License Law for the following reasoi, • | | I. as owner of the property or my employees with wages as their sole compensate License Law does not apply to an owner of property who builds or improves there sale. If, however, the building or improvement is sold within one year of complelio | | I, as owner of the property, am exclusively contracting with licensed contractors u property who builds or improves thereon, and contracts for such projects with con I am exempt under Section __... Business and Professions Code for th 1.1 personally plan to provide the major labor and materials for construction o 2,1 (have / have not) signed an application for a building permit for the propo 3. i have contracted with the following person (firm) to provide the proposed •• 4.1 plan to provide portions of the work, but I have hired the following person'. 5.1 will provide some of the work, but I have contracted (hired) the tallowing ^PROPERTY OWNER SIGNATURE >n. will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's •)i. and who does such work himself or through his own employees, provided that such improvements are not intended or offered for •i. the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). construct the project (Sec. 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of ractorfs) licensed pursuant to the Contractor's License Law). s reason: .he proposed property improvement, j [Yes [ |No 3d work. ustruction (include name address / phone / contractors' license number): .0 coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): i-sons to provide the work indicated (include name' address / phone / type of work): AGENT DATE City of Carlsbad Bldg Inspection Request For: 03/17/2010 Permits CB100243 Title: WOITH RES INSTALL ROOF MOUNT Description: PHOTOVOLTAIC SYSTEM Inspector Assignment: 2618 CAZADERODR Lot: 0 Type: ELEC Sub Type: Job Address: Suite: Location: OWNER WOITH KEITH E&KATHRYN A Owner: WOITH KEITH E&KATHRYN A Remarks: Phone: 8777047652 Inspector: Total Time: CD Description 34 Rough Electric 39 Final Electrical Act Comments Requested By: WEST COAST ELECTRIC Entered By: CHRISTINE Comments/Notices/Holds Associated PCRs/CVs Original PC# Inspection History Date Description Act Insp Comments PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB100243 DATE 2/9/10 ADDRESS 2618 CAZADERO DR RESIDENTIAL ADDITION- MINOR (<17,000.00) RETAINING WALL VILLAGE FAIRE POOL/SPA TENANT IMPROVEMENT COMPLETE OFFICE BUILDING OTHER SOLAR PANELS PLANNER GINA RU ENGINEER DATE 2/10/10 DATE II:\ADMIN\CO(JNTER/PLANNING/ENGINEERING APPROVAL EsGil Corporation In Partnership with government for (Buifding Safety DATE: 02/19/2010 a APPLICANT "JUms> ) JURISDICTION: City of Carlsbad FILE PLAN CHECK NO.: 10-0243 SET: I PROJECT ADDRESS: 2618 Cazadero Dr. PROJECT NAME: Woith Roof Mounted 6 kW PV System The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: XI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person XI REMARKS: Please transfer the clouded redline on sheet PV-3 to all City sets prior to issuing the permit. By: Aaron Goodman Enclosures: EsGil Corporation D GA D EJ D PC 02/18/2010 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 City of Carlsbad 10-0243 02/19/2010 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: Aaron Goodman BUILDING ADDRESS: 2618 Cazadero Dr. PLAN CHECK NO.: 10-0243 DATE: 02/19/2010 Set I BUILDING OCCUPANCY: R-3 TYPE OF CONSTRUCTION: V-B BUILDING PORTION AREA ( Sq. Ft.) Roof Mounted PV System Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb Valuation Multiplier By Ordinance Reg. Mod. VALUE ($) Plan Check Fee by Ordinance Type of Review: Repetitive Fee Repeats D Complete Review D Other r-, Hourly EsGil Fee $107.50 1 $86.00 Structural Only Hr. @ $86.00 Based on hourly rate Comments: Roof Mounted 6 kW PV System Sheet 1 of 1 macvalue.doc + Check a License or Home Improvement Salesperson (HIS) Registration - Contractors Stat... Page 1 of 1 ^p-j- Department of Consumer Affairs ***• - feOV Contractors State Lijgnie*Boarci Contractor's License Detail - License # 810930 £>n DISCLAIMER: A license status check provides information taken from the CSLB license database. Before relying on this information, you should be aware of the following limitations. • •» CSLB complaint disclosure is restricted by law (B&P 7124,6). If this entity is subject to public complaint disclosure, a link for complaint disclosure will appear below. Click on the link or button to obtain complaint and/or legal action information. * Per B&P..7Q71.17, only construction related civil judgments reported to the CSLB are disclosed. •*> Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration. ~» Due to workload, there may be relevant information that has not yet been entered onto the Board's license database. License Number: Business Information: Entity: Issue Date: Expire Date: License Status: Classifications: Bonding: 810930 Extract Date: 02/26/2010 WEST COAST APPLIANCE SERVICES INC dba WEST COAST SOLAR 10744 PROSPECT AVE #B SANTEE, CA 92071 Business Phone Number: (619) 572-6221 Corporation 07/24/2002 07/31/2010 This license is current and active. All information below should be reviewed. CLASS DESCRIPTION C20 WARM-AIR HEAIING, VENIILAIINQ AND AIR-CQNDITIQNING C10 ELECTRICAL CONTRACTOR'S BOND This license filed Contractor's Bond number 69367861 in the amount of $12,500 with the bonding company WESTERN SURETY. COMPANY. Effective Date: 01/01/2007 Contractors. Bonding. History BOND OF QUALIFYING INDIVIDUAL 1. The Responsible Managing Officer (RMO) ALEX PODKOZHURNIKOV certified that he/she owns 10 percent or more of the voting stock/equity of the corporation. A bond of qualifying individual is not required. Effective Date: 07/24/2002 This license has workers compensation insurance with the ENDURANCE REINSURE Workers' Compensation: Policy Number: WEN000941903 Effective Date: 11/14/2009 Expire Date: 11/14/2010 Workers' CornBensatipn.. History Personnel listed on this license (current or disassociated) are listed on other licenses. Personnel List I Other Licenses Conditions of Use | Privacy Policy Copyright © 2010 State of California https://www2.cslb.ca.gov/OnlineServices/CheckLicense/LicenseDetail.asp 02/26/2010 Woith Residense 6.3kW pDC Photovoltaic System Sheet No Description T1 Title Page PV-1 Site Plan PV-2 Mounting Detail, Wire and Conduit Chart PV-3 Single Line Data Sheets Customer Info. Name: Keith Woith Phone: 619-851-1477 Address: 2618 Cazadero Dr Carlsbad, CA 92009 Contractor Info Name: West Coast Solar (DBA West Coast Appliance Services) Phone: (619)557-0446 Address: 10744 Prosprct Ave. Santee, CA 92071 This Project comply with the 2007 California Building Code, which adops the 2006 IBC, 2006 UMC. 2006 UPC and 2005 NEC. 26 2010 ty of CARLSBAD Map «&& ©2010 Google;©2010 Google Sheet Title: Title Page x Issue For ["bate Site Plan 1, Exting 200A Service / 2. Main Meter Base 1. Location of 200A Service 2. Main Meter and Base 3. Proposed Location of Inverter with Integrated DC Disconect 4. Proposed Location of Solar Modules Panels are to be mounted parallel to and six inches above the roof Roof covering shall be designed.instalied and maintained in accordance with this code and approved manufacturer's instruction such thereof covering shall serve to protect the building or structure. CBC1503 ROOF TYPE: Concrete Fiat Tile ROOF PITCH: 4/12 NUMBER OF FLOOR (S): 2 Roof Mount Detail 1 . Pro Solar Fast Jack Racking System, or equal 2. Flush Mounted in 1 groups of 36 Modules 3. Sized for wind loads up to 1 20 mph Model # Module Wetght 0bs) f of Modules Total Module Weight (Ibs.) Rack Weight Total Weight: * of Stand -ofs Loading Per Stand-off Total Area Loadin§ (PSF) 1?5 34.1 36 12276 145.8 1311,4 48 21S1 ?16,?S 1.92 •OtT Number of strings Panels in String 3 12 4. Standard wood construction, 2x6 trusses 24" O,C. to form roof, sheathed with 1/2" plywood. Upper surface of plywood faced with felt paper. Finished roof surface is Concrete Fiat Tile. 5. Roof mounting system to be attached to trusses at 4' to 6* O.C. depending on truss location, 6.Mounting accordantly factory specification (see attached drawings) 7. Roof penetrations are sealed with Schnee Morehead 7108 sealant. Wire Runs, Amperage, Voltage Drop and Conduit Chart Array t Wire Run Amps Max Amps Max w/NEC Multiplier Fuse or Breaker Ams Min Voltage Max DC/AC One Way Dtst (ft.) 30 Vdrapjsi Qty Copper Conductors * in Parallel AWG fnsul Ground Qty AWG 10 Worst Case Vdrop Minimum Conduit 2S[.;«g ...i JiL JE Average Ambient Temperature (F) Minimum Historical Temperature {F} Conduit Mwttmu Oistartct to Roof (in _) Temperature Aider |F) 310 15fBX2)c 108 15 40 Total DC Voltage Of cp Totat AC Voltage Drop Trt* S^sttw Vota^i^ &op &lt% OJ5% 1,33% Issue For: ! Date 1_L ——i « Sheet Title: Mounting Detail, Wire and Conduit Chart Scale: Sheet: PV-2 Notes 1. Key Manufacturers arc: - Modules, SunTech Power America 71 Stevenson Street, 10th Floor, San Francisco, CA 94105. Tel: 619-661-1134 Fax:619-661-6795 - Inverter, SMA America 4031 Alvis Court Rocklin. CA 95677 -Racking, Professional Solar 4630 Calle Quetzal Camarillo, CA 93012 2. All components are UL listed and CEC certified, where warranted. 3. The solar PV system will be installed in accordance with Article 690 of the 2005 NEC and the 2007 CEC. 4. (11 existing 200A Service Entrance will be used. 5. DC Markings: Markings shall be placed every 5 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, at turns, above/or below penetrations, all DC combiners, and junction boxes. 6. Height of Integrated AC/DC Disconnect shall not exceed 6'-7" per NEC 240.24. 7. A grounding electrode system in accordance with NEC 690-47 and 250-50 through 60 and 250-166 shall be provided. Per NEC, grounding electrode system of existing building may be used and bonded to at the service entrance. If existing system is inaccessible or inadequate, a supplemental grounding electrode will be used at the inverter location consisting of a UL listed 8 ft ground rod with acom damp. Grounding electrode conductors shall be no less than #8AWG and no greater than #6AWG copper and bonded to the existing grounding electrode to provide for a complete: Photovoltaic Array - Typical of 1 36 Switch PV44odute STP175S - 24/Ab A 1 combiner with 3 serias strings of 12 modules each String: PflBX Pm» v=^p v*n0 Imp Isc i 17500 ! | 3520 4240 1 495 i 5.20 WsttSTC- Module Wai! SIC Volts maxowwr - Volts nix power Amps max power Amps sftort ctttwl Voc Voc 156.0fl!W»Ptc- Module *yimm Vote span otcwt • Module Volts open circud ? ?2jAmp$ • Design Pmax i Vmp i Imp Isc ! 12140 14* 1560 Walls STC Volts max pow Amps faax power Amps start circuit Voc 5S«»|W«$PTC 5304li¥8fis apffl Ofcuit 23 17lAmps - Design ffoo/ of Dwelling Intermodule wiring51 OiiraSheatl) Low-Voitage Power, Unshielded, EPR. HYP. Volts: 600V. UL Type RHH RHW-2• USI -2, Conductor Size (AWO'Ticmil): 10. Conductor Steads: 7 .0612, Rated at 90C wet or dry with Multi-Contact connectors. Voc and Vmp are calculated towed on minimum and maximum temperatures. See page PV-2 for details. Total for system:5616,00 WaBs PTC <X___- , . •.!•._._ II3#-^, J-Box Conductor-; are *10 AWC IJSF-2 ""& piound is Solid ** 10 A WO under array in open-air. , Conductors arc #10 AWG THWN-2 & '" ground is #10 AWG THWN-2 in 3-4" or larger conduit Conductors arc WJAWG THWN-2 & ground is «XAWG THWN-2 In 34" or larger conduit All grounds and neutrals bonded through here to existing grounding conductor SB6000 Side of Dwelling 200A Service Entrance 200A CB (1W» 3S Amp CB KWH SMA America SB6000US (240V) Inverter with Integrated 20A Fused DC Disconnect. One fuse per string required. Rated for 600VDC. Typical of one Max Power: 6000W CEC Efficiency: 95.5% Input: 200-600VnC Output: 240VAC («; 60H* lmax=25A l!We=3l,2SA({§!25%) Iniemai GFDI (idif>1000niA» NEMA JR Enclosure UL1741 WAltNRK. FJ-EtTRK: SM«K:K H */A«t» -DO>iOT If M (Hit «M».\ Al HI KKM ON BOTH THE I INK ANDTHK I.f»U> S1HJ.N VI\\ Bt KMJW.t/ir*l\ I'll! OH- PtKtTt \IC OlSt ONNtt. I ( At IKJN W»W I K I OI His ill UJHN<; tt AI SO HI f|*| .11f> fr KO^I t MI roi4.owisr. soi«« rs WITH IJISCIiNNH IS TAITION: SOLAR ELECTRIC' SYSTEM CONNECTKI) Placards issue For. Date \ O -S3 o Sheet Title: Single Line Scale: Sheet: PV-3 SSUNTECH Solar powering a green future BLACK LABEL STP180S-24/Ab-1 STP175S-24/Ab-1 STP170S-24/Ab-1 STP165S-24/Ab-1 STP160S-24/Ab-1 175 Watt MONO-CRYSTALLINE SOLAR PANEL Suntech Black Label™ modules are exclusively designed and engineered for homeowners who seek a rooftop solar solution that combines visual aesthetics with excellent efficiency. Features • High conversion efficiency based on innovative photovoltaic technologies • High reliability with guaranteed +/-3% power output tolerance • Withstands high wind-pressure and snow load, and extreme temperature variations Quality and Safety • 25-year power output transferable warranty • Rigorous quality control meeting the highest international standards • ISO 9001:2000 (Quality Management System) and ISO 14001:2004 (Environmental Management System) certified factories manufacturing world class products • UL listings: UL1703, cULus, Class C fire rating, conformity to CE Recommended Applications • Residential rooftop systems • On-grid utility systems • On-grid commercial systems I us C€ Suntech's technology yields improvements to BSF structure and anti-reflective coating to increase conversion efficiency The panel provides more field power output through an advanced cell texturing and isolation process, which improves low irradiance performance Unique design on drainage holes and rigid construction prevents frame from deforming or breaking due to freezing weather and other forces 2QO& Suntech was named Frost and Sullivan's 2008 Solar Energy Development Company of the Year www.suntech-power.com | E-mail: sales@suntech-power.com STP is a trademark of Suntech Power Holdings Co., Ltd. All rights reserved STP-DS-STD-N01.01 Rev 2008 © Copyright 2008 Suntech Power SSUNTECH Solar powering a green future Electrical Characteristics Characteristics STP180S-24/Ab-1 Open - Circuit Voltage (Voc) 44.4V STP180S-24/Ab-1 STP175S-24/Ab-1 BLACK LABEL™ STP170S-24/Ab-1 STP165S-24/Ab-1 STP160S-24/Ab-1 STP175S-24/Ab-1 44.2V STP170S-24/Ab-1 43.8V STP165S-24/Ab-1 43.6V STP160S-24/Ab-1 43.2V Optimum Operating Voltage (Vmp) Short - Circuit Current (Isc) Optimum Operating Current (Imp) Maximum Power at STC (Pmax) Operating Temperature Maximum System Voltage Maximum Series Fuse Rating Power Tolerance 35.6V 5.4A 5.05A 180Wp -40°C to +85°C 600V DC 15 AMPS ±3% 35.2V 5.2A 4.95A 175Wp -40°C to +85°C 600V DC 15 AMPS ±3% 35.2V 5.14A 4.83A 170Wp -40°C to +85°C 600V DC 15 AMPS ±3% 34.8V 5.04A 4.74A 165Wp -40°C to +85°C 600V DC 15 AMPS ±3% 34.4V 5A 4.65A 160Wp -40°C to +85°C 600V DC 15 AMPS ±3% STC: Irradiance 1000W/m2, Module temperature 2S°C, AM=1.5 Drainage holes ^ 14x9 [O.SSxO.351 /T Mounting slots 8 places Mechanical Characteristics 2-e5.1 [B0.2] Ground holes 2 places Section A-A Note: mm [inch] Solar Cell Mono-crystalline 125x125mm (Sinch) No. of Cells 72(6x12) Dimensions 1580x808x35mm (62.2x31.8x1.4inch) Weight Front Glass 15.5kg (34.1 Ibs.) 3.2 mm (0.13inch) tempered glass Frame Junction Box Anodized aluminium alloy IP65 rated AIW (12AWG), asymmetrical lengths (-) 1200mm Output Cables (47.2inch) and (+) 800mm (Sl.Sinch), MC Plug Type IV connectors Temperature Coefficients Nominal Operating Cell Temperature (NOCT)45°C±2°C Temperature Coefficient of Pmax Temperature Coefficient of Voc Temperature Coefficient of Isc -0.48 %/°C -0.34 %/°C 0.017%/°C Current-Voltage & Power-Voltage Curve (170W)Temperature Dependence of Isc, Voc, Pmax 10 15 25 30 35 40 Voltage(V) -SO -25 0 25 50 75 100 Cell Temperature (°C) www.suntech-power.com | E-mail: sales@suntech-power.com STP-DS-STD-N01.01 Rev 2008 SB 8000US AVAILABLE IN 2010 Highest CEC efficiency in its class Integrated load-break rated lockable DC disconnect switch Integrated fused series string combiner Sealed electronics enclosure & Opticool™ Comprehensive SMA communications and data collection options Ideal for residential or commercial applications Sunny Tower compatible 10 year standard warranty UL 1741/IEEE-1547 compliant SUNNY BOY 5000US/6000US/7000US/ 8000US The best in their class Our US series inverters utilize our proven technology and are designed specifically to meet IEEE-1547 requirements. Sunny Boy 6000US, Sunny Boy 7000US and Sunny Boy 8000US are also compatible with the Sunny Tower. Increased efficiency means better performance and shorter payback periods. All four models are field-configurable for positive ground systems making them more versatile than ever. Throughout the world, Sunny Boy is the benchmark for PV inverter performance and reliability. Technical Data SB5000US SB6000US SB 7000US SB 8000US Recommended Maximum PV Power (Module DC Maximum Voltage Peak Power Tracking Voltage DC Maximum Input Current Number of Fused String Inputs PV Start Voltage AC Nominal Power AC Maximum Output Power STC) 6250 W 600V 250-480 V 21 A 7500 W 8750 W 10000W Si600 V 600 V 600 V 250-480 V 250-480 V 300-480 V 25 A 30 A 30 A O 3 (inverter), 4 x 20 A 3 (inverter), 4 x 20 A 3 (inverter), 4 x 20 A 3 (inverter), 4 x 20 A | (DC disconnect) 300V 5000 W 5000 W AC Maximum Output Current (@ 208, 240, 277 V) 24 A, 2 1 A, 1 8 A AC Nominal Voltage Range (DC disconnect) (DC disconnect) (DC disconnect) ^ o 300V 300V 365V J 6000 W 7000 W 8000 W O 6000 W 7000 W 8000 W a 29 A, 25 A, 22 A 34 A, 29 A, 25 A N/A, 32 A, 29 A 183 -229V@208V 183 - 229 V@ 208 V 183 - 229 V@ 208 V N/A@208V 211 -264V@240V 211 - 264 V@240 V 211 - 264 V@ 240 V 211 - 264 V@ 240 V J 244-305V@277V 244 - 305 V@ 277V 244 - 305 V@ 277V 244 - 305 V@ 277V r AC Frequency: nominal / range Power Factor [Nominal) Peak Inverter Efficiency CEC Weighted Efficiency Dimensions: Wx h x D in inches Weight / Shipping Weight Ambient Temperature Range Power consumption at night Topology Cooling Concept Mounting Location LCD Display a. 60 Hz/ 59.3 -60.5 Hz 60 Hz/ 59.3 - 60.5 Hz 60 Hz/ 59.3 - 60.5 Hz 60 Hz/ 59.3 - 60.5 Hz \ :> 0.99 96.8% 95.5% @ 208V 95.5% @ 240 V 95.5% @ 277V 18.4 x24.1 x9.5 141 Ibs /1 48 Ibs -13 to 113 °F 0.1 W 0.99 0.99 0.99 'sO)eiO97.0% 97.1% 96.5%7£ 95.5% @ 208V 95.5% @ 208V N/A @ 208V | 95.5% @ 240V 96.0% @ 240V 96.0% @ 240V 96.0% @ 277V 96.0% @ 277V 96.0% @ 277V 1 to 18.4x24.1x9.5 18.4x24.1x9.5 18.4x24.1x9.5 141 Ibs/ 148 Ibs 141 Ibs/ 148 Ibs 148 Ibs/ 152 Ibs -13 to 113 °F -13 to 113 °F -13 to 113 °F 0.1 W 0.1 W 0.1 W ^ 0 Low frequency transformer, Low frequency transformer, Low frequency transformer, Low frequency transformer, £ true sinewave OptiCool™, true sinewave true sinewave true sinewave f OptiCool™, OptiCool™, OptiCool™, | forced active cooling forced active cooling forced active cooling forced active cooling J indoor/ outdoor (NEMA3R) •/• Communication: RS485 / wireless Warranty: 10 years / 15 years / 20 years • 0/0 •/O/O Compliance: IEEE-929, IEEE-1547, UL 1741, •/• •/• •/• • • • IT3 O/O O/O O/O 03 •/o/o */o/o •/o/o <? Si04K A Jh UL 1998, FCC Part 15 A&B ' " " J Specifications for nominal conditions NOTE: US inverters ship with gray lids. Efficiency Curves 98 96 94 / / £92 FT 90 / 88 86 " /f /"/ ••' — SB 7000US | 1000 2000 3000 PA • --^ — -> — — 4— • — URY - 250 V DC 1 - UK - 310 V DC - Upv-480VDC | 4000 5000 6000-tw] • Included O Optional J 1i/l D hl.g^d^^.,!8888^ 1 loc ramote ntilinr i jP"*"****™*1* data from any PC p S feSPB^1"'^ ^SS^fe^iBi I* • -•• B 1 '• * &• • 9* & • '• ... ,<1BM^» % ~ i lor data *tofage add • ,^^ _ ™^... • csj ^^V dowtond to o PC Memory expansion Cl and dolo iran.raliS.Drv S ,S±£?D°«,,d ^1375=735=";. Smaro'vsi5 p'°g'a™ • fa-sfcr | Tel.+1 9166250870 Toll Free +1 888 4 SMA USA www.SMA-America.com SMA America, LLC