HomeMy WebLinkAbout2618 EL CAMINO REAL; ; CB991061; Permit06/23/1999 City of Carlsbad Commercial/Industrial Permit Permit No Building Inspection Request Line (760)438-3101 CB991061 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2618 EL CAMINO REAL CBAD Tl Sub Type COMM Lot# 0 $49,000 00 Construction Type NEW Reference # SMART AND FINAL HVAC PLATFORMS AND HVAC UNITS Applicant MILLER CONSTRUCTION 1930 WATSON WY. SUITE K VISTA, CA 92083 619599-4031 Status Applied Entered By Plan Approved Issued Inspect Area ISSUED 03/18/1999 DT 06/23/1999 06/23/1999 Owner 1201 06/23/99 0001 01 C-PRMT 02 426-32 Total Fees $683 74 iTotaljRaymentS'To Date $257 O Balance Due $426 32 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee $1 0-29? $000'$o'6b600 Reel Water Con •^Mete r^Size 5&djl'Recl-Water Con ^Fteeu** * " f -y- V^P" 4 t ' - - ~*CFD License Tax i NCORf license Tax,(<SFD*Fund)I^^O / ^ f\ s ***& -&tJTaffic Impact Fee ffi^lnjpactY^FD' Fund) if MZ T/a Repartition /Fee $000 ELEJRIOAL'TOTAL MEGHANlCAL TOTAL Master Drainage Fee Sewer Fee TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $2000 $000 $000 $000 $683 74 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred tcj as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing m accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (760) 438-1161 07/21/1999 City of Carlsbad Commercial/Industrial Permit Permit No* CB991061 Building Inspection Request Line (760) 438-3101 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2618 EL CAMINO REAL CBAD Tl Sub Type COMM Lot# 0 $49,000 00 Construction Type NEW Reference # SMART AND FINAL HVAC PLATFORMS AND HVAC UNITS Applicant MILLER CONSTRUCTION 1930 WATSON WY, SUITE K VISTA, CA 92083 619 599-4031 Status Applied Entered By Plan Approved Issued Inspect Area ISSUED 03/18/1999 DT 06/23/1999 06/23/1999 RB Owner 2095 07/21/99 0001 01 C-PRMT 02 30-00 Total Fees $71374 Total^ayments'To-DaW g;$683 74 Balance Due $30 00 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee $396 03 $000 Recl Water Con (Fee* eterSize Sd'l'Recl 'Water Con jRee EF-(CED-Fijnd)«f j vfiju*-"' ,;License Tax INCO™l2icense ^$0-00 $0^00 $0^00 $1fo „ .tTraff ic, Impact; Fee" MJ-— ^ ^ J^ 'l"^\ \\ \^VTrafficlmpact MZ Trajispprjation'ree 'SO'OO ^$0 00. $30 00 $000 $000 lECftANICAL TOTAL Master Drainage Fee Sewer Fee TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $2000 $000 $000 $000 $71374 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest triem, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this or as to which the statute of limitations has previously otherwise expired CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (760) 438-1161 PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 2075 Las Palmas Dr, Carlsbad CA 92009 (760)438-1161 iT PROJECT, INFORMATION Tffi" FOR OFFICE USE ONLY PLAN CHECK NO/. EST VAL £| Plan Ck Deposit Validated By_ Date .3//S/99 Address (include Bldg/Suite #)Business Name {at this address) Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor's Parcel #Existing Use I*, & S'Q FT Proposed Use Description of Work #of Stones # of Bedrooms of Bathrooms 7w'« Name AddressAooress - C^coT^ajSo'r ^ C^^s^^LOsbir^^oTZL. O I&cy^LL. [3 Name Address Name Address City State/Zip Telephone # l5!I^NTRACTOR~!^^ (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter, improve demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to fiie a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [5500]} Name State License # Designer Name State License # <225*>i \ Address . £1 2? f-lLicense Class rrj) fh Address i y City Slate/Zip Telephone » fyC. City Business License # '^^"T^Sfc? City State/Zip Telephone •ytPFT'i."Ic n»iH>l,r t, *U,s^sU. m, Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations Q I have and will maintain a certificate of consent to self-insure for workers compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued Q5^ I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My worker's compensation insurance carrier and policy number are Insurance Company ^jtOuCfcsO f^TJ^liS' Policy No /-JuJU>^>)"?*?.£/0Z— Expiration Date_ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [5100] OR LESS) n CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure^wo«ers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred j!L,,.£i&id^!nj_™!Ntt-LULi«J.iiiMl> thousand dollars (S100 OOfl}, in^Udition tpr^tyfeybost of compensation, damages as provided for in Section 3706 of the Laboj_code,jntere^J §nd attorney s fees SIGNATURE — ' •' • r •;«" nr"--~ ; .*-**-in**-».i ^"T-^t"^y^jv~^j-^^^^j-tiM^iMHim* ****.,*„i^i-.r. r. r t - 5 -•< UC—±~~aiu*~:,* n-jJ.,..i..,...-«-~ L—^.a^ijuJlaiu^jiJ*!...irt i^UjJAiJI hereby affirm that I am exempt'from the Contractor's License Law for the following reason Q 1, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) Q I am exempt under Section .. Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement O YES QNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work {include name / address / phone number / contractors license number) 5 1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) . PROPERTY OWNER SIGNATURE DATE ^ Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley- Tanner Hazardous Substance Account Act7 Q YES (jfl NO Is the applicant or future building occupant required to obtain a permit from the arr pollution control district or air quality management district? Q YES Is the facility to be constructed within 1 ,000 feet of the outer boundary of a school site? CI YES TjjQ NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT ^U.1 ^JULui-w ^i lii^c ^l^^^J I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER'S NAME , LENDER S ADDRESS RF{3j7A"pPUCA^f^ERTlFICATION^^^ I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavauoftfi. over 5'0" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the Bfjilding/Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not conTmence/within 2^3 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the woj* IE comr/enced iftfa Jqriod of 180 days (Section 106 4 4 Uniform Building Code) APPLICANT S SIGNATURE DATE ^'/O WHITE File YELLOW Applicant PINK Finance City of CarlsbadTnspection Request For 7/30/99 Permit# CB991061 Title SMART AND FINAL Description HVAC PLATFORMS AND HVAC UNITS Inspector Assignment RB Sub Type COMM 2618 EL CAMINO REAL Lot 0 Type Tl Job Address Suite Location APPLICANT MILLER CONSTRUCTION Owner HANDYMAN/STORE EXPENSE Remarks GAS METER AND HVAC FINAL Phone 7608014051 Inspector Total Time CD Description 23 Gas/Test/Repairs 29 Final Plumbing 49 Final Mechanical Requested By NA Entered By CHRISTINE Act Comments Inspection History Date Description 7/28/99 23 Gas/Test/Repairs 7/20/99 23 Gas^est/Repairs CO PS 7/19/99 49 Final Mechanical CA PS 7/13/99 23 Gas/Test/Repairs CO RB NEED 24 HR TEST 7/9/99 23 Gas/Test/Repairs PA RB 7/7/99 23 Gas/Test/Repairs CA RB Act Insp Comments CO RB PAY REINSP FEE AGAIN - SEE NOTICE ATTACHED REINSP FEE DUE - SEE NOTICE ATTACHED'* HAVE 60# TEST HOLD TIL MONDAY UNSCHEDULED BUILDING TNSPF.rTTON DATE ' <^! '/ INSPECTOR PERMIT # Q 3 \ nt* \ PLAN CHECK #" l^^"^^"^"^^^"^**^^^ ' JOB ADDRESS DESCRIPTION CODE DESCRIPTION ACT COMMENTS 2- _ CITY OF CARLSBAD BUILDING DEPARTMENT NOTICE - (760)438-3550 /• 2075 LAS PALMAS DRIVE " " DATE X LOCATION TIME r-+ C FOR INSPECTION CALL (760) 438-3101 RE-INSPECTION FEE DUE1? L_J YES - 3 FOR FURTHER INFORMATION, CONTACT - , BUILDING INSPECT CODE ENFORCEMENT OFFICER CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE LOCATION PERMIT NO (760) 438-3550 2075 LAS PALMAS DRIVE TIME a? FOR INSPECTION CALL (760) 438-3101 RE-INSPECTION FEE DUE? YES , CONTACT PHONE CODE ENFORCEMENT OFFICER •/^-'~ CITY OF CARLSBAD BUILDING DEPARTMENT DATE LOCATION PERMIT NO {760)438-3550 2075 LAS PALMAS DRIVE TIME -T O ~ FOR INSPECTION CALL (760) 438-3101 RE-INSPECTION FEE DUE? L_J YES FOR FURTHER INFORMATION, CONTACT _______ PHONE BUILDING INSPECTOR CODE ENFORCEMENT OFFICER EsGil Corporation In Tartncrsfiip with government for Viui&tinff Safety DATE June 8, 1999 JURISDICTION Carlsbad a FILE PLAN CHECK NO 99-1061 SET III PROJECT ADDRESS 2618 El Camino Real PROJECT NAME T. I. (HVAC UNITS & PLATFORMS) for Smart & Final X] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes PLEASE SEE REMARKS BELOW. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person Xl Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person X] REMARKS 1. THIS PLAN CHECK /S FOR THE INSTALLATION OF NEW ROOF MOUNTED HVAC EQUIPMENT AND ONE NEW ELECTRICAL PANEL "M", AND THREE FUSED DISCONNECTS (ALL PROVIDING POWER TO THE NEW HVAC EQUIPMENT). IT IS NOT FORA COMPLETE TENANT IMPROVEMENT PERMIT. -&^HE-MEGH FORM O/V-SHEEL1 TrTHE-MBCtWCALDESIGNER. e^r•*x « By Abe Doliente Enclosures Esgil Corporation n GA D MB O EJ D PC 6/1/99 trnsmtldot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (619)560-1468 + Fax (619) 560-1576 I . .^.- v f EsGil Corporation In Partnersnip zuitfa government for 3$ ui&ing Safety DATE May 7, 1999 Q APPLICANT JURISDICTION Carlsbad CTprAN REVIEWER a FILE PLAN CHECK NO 99-1061 ' SET II PROJECT ADDRESS 2618 El Camino Real PROJECT NAME T. I. (HVAC UNITS & PLATFORMS) for Smart & Final . The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Miller Construction 1241 Distribution Way, Vista, CA 92083 Xl Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgi! Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person REMARKS By Abe Doliente Enclosures Esgil Corporation D GA D MB [X] EJ D PC 4/29/99 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (619)560-1468 + Fax (619) 560-1576 Carlsbad 99-1061 II May 7, 1999 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad PROJECT ADDRESS 2618 El Camino Real DATE PLAN RECEIVED BY ESGIL CORPORATION 4/29/99 REVIEWED BY: Abe Doliente PLAN CHECK NO : 99-1061 SET II DATE RECHECK COMPLETED May 7, 1999 FOREWORD (PLEASE READ): This plan review is" limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit two new sets of prints to ESGIL CORPORATION B To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the - revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes QNo Carlsbad 99-1061 II May 7, 1999 3 Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code Check final sets of plans for signatures. 4 Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1994 UBC, UMC and UPC and 1993 NEC. 5 Please see the following corrections for plumbing, mechanical and energy PLUMBING, MECHANICAL AND ENERGY CORRECTIONS PLAN REVIEWER: Eric Jensen MECHANICAL (1994 UNIFORM MECHANICAL CODE) 1 Is this permit for the installation of mechanical units and their supporting curbs or is it a tenant improvement permit transferring previously unoccupied space into retail store space9 If not a tenant improvement permit, clearly note on the Title -Sheet that the permit is for the installation of new mechanical units and is not a tenant improvement permit" 2 Include the ladder description on the roof access hatch note shown on the floorplans - 3 Detail the disposal sites of the mam condensate drainage from the air conditioning units UMC 310 What is "the approved receptor'"? ENERGY CONSERVATION 4 Provide plans, calculations and worksheets to show compliance with current energy standards The remaining energy design needs to be submitted LTG and ENV forms 5 Provide complete energy designs for the proposed changes in envelope, lighting, and mechanical systems Provide the completed ENV-1, ENV-2, ENV-3; LTG-1, LTG-2, MECH-1, MECH-2, MECH-3, and MECH-4 forms showing energy compliance 6 On the plans clearly show the wall and roof insulation locations, thickness, and R-values, as per the energy design 7 Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section 131(d) 8 Show bi-level lighting controls as per Title 24, Part 6, Section 131 (b) Carlsbad 99-1061 II May 7, 1999 9 Detail required exterior lighting controls "Exterior lighting controlled from a lighting panel within the building shall be controlled by a directional photocell or astronomical time switch that automatically turns off exterior lighting when daylight is available" 10 The completed and signed ENV-1, LTG-1, and MECH-1 forms must be imprinted on the plans 11 Specify on the building plans all of the mandatory energy conservation requirements as listed on the enclosure titled, "Mandatory Measures Checklist" 12 Complete energy plan check will be done when complete corrected energy designs are provided Note: If you have any questions regarding this Plumbing, Mechanical, and Energy plan review list please contact Erie Jensen at (619) 560-1468 To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans EsGil Corporation In Partners/lip with government for DATE March 30, 1999 Q APPLICANT JURISDICTION Carlsbad Q PLAN REVIEWER a FILE PLAN CHECK NO • 99-1061 SET I PROJECT ADDRESS 2618 El Camino Real PROJECT NAME T. I. (HVAC UNITS & PLATFORMS) for Smart & Final The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person X| The applicant's copy of the check list has been sent to Miller Construction 1241 Distribution Way, Vista, CA 92083 XI Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person REMARKS By Abe Doliente Enclosures Esgil Corporation GA MB I EJ D PC 3/22/99 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (619)560-1468 * Fax (619) 560-1576 Carlsbad 99-1061 March 30, 1999 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO 99-1061 OCCUPANCY M TYPE OF CONSTRUCTION V-N ALLOWABLE FLOOR AREA Existing SPRINKLERS'? REMARKS HVAC platform & Unit only DATE PLANS RECEIVED BY JURISDICTION DATE INITIAL PLAN REVIEW COMPLETED March 30, 1999 JURISDICTION Carlsbad USE Store ACTUAL AREA Existing STORIES Existing HEIGHT OCCUPANT LOAD no change DATE PLANS RECEIVED BY ESGIL CORPORATION 3/22/99 PLAN REVIEWER Abe Doliente FOREWORD (PLEASE READ). This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 1994 UBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. LIST NO 40, TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1994UBC)tforw dot Carlsbad 99-1O61 March 30, 1999 1 Please make all corrections on the original tracings and submit two new sets of prints, to Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123, (619)560-1468 2 Please make all corrections on the original tracings and submit two new sets of prints, to The jurisdiction's building department 3 Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code 4 Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1994 UBC, UMC and UPC and 1993 NEC • MISCELLANEOUS 5 Please see the following corrections for electrical, plumbing, mechanical and energy 6 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc 7. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes P No Q Carlsbad 99-1061 March 30, 1999 PLUMBING, MECHANICAL AND ENERGY CORRECTIONS PLAN REVIEWER: Eric Jensen MECHANICAL (1994 UNIFORM MECHANICAL CODE) 1 Is this permit for the installation of mechanical units and their supporting curbs or is it a tenant improvement permit transferring previously unoccupied space into retail store space'? If not a tenant improvement permit, clearly note on the Title Sheet that the permit is for the installation of new mechanical units and is not a tenant improvement permit 2 Include the ladder description on the roof access hatch note shown on the floorplans 3 Detail the disposal sites of the mam condensate drainage from the air conditioning units UMC 310 What is "the approved receptor'"? 4 Submit electrical plans showing feeders, branch circuits, panels, panel schedules, service size, disconnects, and convenience receptacle outlets for the mechanical system 5 Provide smoke detection in supply air duct of 'air-moving system' for required shut-off for smoke control as per UMC, Section 608. This is required for almost all HVAC units An "Air-moving system (see definition in UMC 203) is a system designed to provide heating, cooling, or ventilation in which one or more air-handling units are used to supply air to a common space or to draw air from a common plenum or space" ENERGY CONSERVATION 6 Provide plans, calculations and worksheets to show compliance with current energy standards The remaining energy design needs to be submitted LTG and ENV forms 7 Provide complete energy designs for the proposed changes in envelope, lighting, and mechanical systems Provide the completed ENV-1, ENV-2, ENV-3, LTG-1, LTG-2, MECH-1, MECH-2, MECH-3, and MECH-4 forms showing energy compliance 8 On the plans clearly show the wall and roof insulation locations, thickness, and R-values, as per the energy design Carlsbad 99-1O61 March 30, 1999 9 Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section 10 Show bi-level lighting controls as per Title 24, Part 6, Section 131(b) 1 1 Detail required exterior lighting controls "Exterior lighting controlled from a lighting panel within the building shall be controlled by a directional photocell or astronomical time switch that automatically turns off exterior lighting when daylight is available " 12 The completed and signed ENV-1, LTG-1, and MECH-1 forms must be imprinted on the plans 13 Specify on the building plans all of the mandatory energy conservation requirements as listed on the enclosure titled, "Mandatory Measures Checklist" 14 Complete energy plan check will be done when complete corrected energy designs are provided Note: If you have any questions regarding this Plumbing, Mechanical, and Energy plan review list please contact Eric Jensen at (619) 560-1468 To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans Carlsbad 99-1061 March 30, 1999 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PLAN CHECK NO 99-1061 PREPARED BY Abe Doliente DATE March 30, 1999 BUILDING ADDRESS- 2618 El Camino Real BUILDING OCCUPANCY M TYPE OF CONSTRUCTION V-N BUILDING PORTION T 1 HVAC platform And Unit Air Conditioning Fire Sprinklers TOTAL VALUE BUILDING AREA (ft2) VALUATION MULTIPLIER Per city VALUE ($) 49,000 49,000 [X] 1994 UBC Building Permit Fee G Bld9 Permit Fee by ordinance $ 39602 [X] 1994 UBC Plan Check Fee Q Plan Check Fee by ordinance $ 25741 Type of Review [^ Complete Review G Structural Only G Hourly G Repetitive Fee Applicable G other Esgil Plan Review Fee $ 205 93 Comments Sheet 1 of 1 macvalue doc 5196 PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB ADDRESS DATE RESIDENTIAL RESIDENTIAL ADDITION MINOR « $10,000.00) TENANT IMPROV PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER ENGINEER DATE DATE Docs/Mlsforms/Wanntng Engineering Approvals PLUMP ENGINEERING. INC. Structural Engineering STRUCTURAL CALCULATIONS Client: Project: Location: MILLER CONSTRUCTION SMART & FINAL 2618 EL CAMINO REAL, CARLSBAD, CA Building Code: 1994 UBC Plump File No: 980907 Revisions: By: R.P. Date: September 23, 1998 i These calculations not valid unless signed and sealed in space above 2O1 O1 SW Blroh Street, Suite 210 Newport BeaoH, CA 82BBO (B4O) 474-E14O Fax (94B) 474-424O PLUMP ENGINEERING, INC. 20101 S W. BIRCH STREET, SUITE 210 NEWPORT BEACH, CA 9266Q 949-474-2140 FAX 949-474-4240 E-MAIL: PLUMPENG@EARTHLINK NET Title SMART & FINAL Dsgnr RP Description Scope Job # 980907 Date R«- sioooi Horizontal Plywood Diaphragm page i"| Description CHECK SHEAR General Information North-South Length 1 80 00 ft Ease-West Length 1GO 00 ft Nort-South Chord 180 00 ft East-West Chord 160 00 ft Boundary Loads Acting North & South # 1 2,097 00 #/ft from # 2 #/ft from # 3 #/ft from # 4 #/ft from Boundary Loads Acting East & West # 1 2,097 00 #/ft from # 2 #/ft from # 3 #/ft from # 4 #/ft from - I Diaphrgm Weight 1 3 00 psf Seismic Factor 0 1830 Diaphragm is Blocked Blocking Direction North-South - - " | 0000ft to 160000ft 0000ft to 0000ft 0 000 ft to 0 000 ft 0 000 ft to 0 000 ft I 0000 ft to 180000ft 0 000 ft to 0 000 ft 0 000ft to 0 000 ft 0 000 ft to 0 000 ft ITiorth & Soulh Walls I Design Data & Nailing Requirements Shear Zone Framing I hickness in At North Wall 3x 1/2" 2nd zone 3x 1/2" 3rd zone 3x 1/2" Center zone 3x 1/2" 3rd zone 3x 1/2" 2nd zone 3x 1/2" At South Wall 3x 1/2" Grade Nail Size Spacing Value Distance in #/ft ft Structural I 10d 2,3,12 820 0 0 00 Structural I 10d 2 5,4,12 720 0 0 00 Structural! 10d 4,6,12 4800 1512 Structural I 10d 6,6,12 360 0 Structural! 10d 4,6,12 4800 1512 Structural I 10d 2 5,4,12 720 0 0 00 Structural 1 10d 2,3,12 8200 000 (East & West Walls | Design Dafe & Nailing Requirements - , * At West Wall 2nd zone 3rd zone Framing 3x 3x 3x Center zone 3x 3rd zone 2nd zone At East Wall 3x 3x 3x Thickness in 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" Grade Structural Structural Structural Structural Structural Structural Structural Nail Size 10d 10d 10d 10d 10d 10d 10d Spacing in 2.3.12 25,4.12 4,6,12 6.6,12 4,6,12 25.4.12 2.3.12 Shear Value #m 8200 7200 4800 3600 4800 7200 8200 Zone Distance ft 000 000 064 064 000 ooo SKear & Chord Forces Diaphragm Shears Noith Total Shear 68,795 2 Ibs Shear per Foot Chord Forces @ 1/4 * Length @ 1/2* Length @ 3/4 * Length Length / Width Ratio 1 429 97#/ft 125 South 68 .795 2 Ibs 42997#/ft 10,768 3lbs 14,4350 Ibs 10,883 8 Ibs West East 64,957 7 Ibs 64,9577 Ibs 3G088#/ft 36088 #/ft 14,433 8lbs 19,348 6 Ibs 14.588 6 Ibs I (c}1983-98 ENERCALC"c \enercalc\980907 ecw'Calculatiorts KW-06016117Ver506;i5-~Jul-1998,~Wiri32~ PLUMP ENGINEERING, INC. 20101 S.W. BIRCH STREET, SUITE 210 NEWPORT BEACH, CA 92660 949-474-2140 FAX 949-474-4240 E-MAIL: PLUMPENG@EARTHLINK NET Trtle SMARTS, FINAL Dsgnr RP Description Scope Job # 980907 Date Single Span Beam Analysis Page 1 Description CHECK SHAER General Information Center Span 16000 ft Left Cantilever ft Right Cantilever ft Uniform Loads On Center Span #1 0812 k/ft Query Values Center Location Moment , - ' Shear ^- _ Deflection -### AT SKYLIGHTS - ALONG Moment of Inertia Elastic Modulus Beam End Fixity On Left Cantilever #1 8 000 ft Left Cant 75"85-k-ft 58 71 k N j jj If tTn — — — — — -*^fiffitrfj in 180' LENGTH 1 000 m4 1 ksi Pin-Pin k/ft 0 000 ft 0 00 k-ft 000k 0 00000 tn 8' IN FROM END | | On Right Cantilever # 1 k/ft | Right Cant 0 000 ft 0 00 k-ft 000 k 0 00000 in 1 Summary * Moments Max •*• @ Center Max - @ Center @ Left Cant @ Right Cant Maximum = ] 2,598 39 k-ft at 8016ft 000 k-ft at 16000ft 0 00 k-ft 0 00 k-ft 2,598 39 k-fl Shears @Left @ Right Maximum Deflections @ Center @ Left Cant @ Right Cant 6496k 6496k 6496 k -####### in 0 000 in 0 000 in Reactions @Left @ Right at 80 16 ft at 0 00 ft at 0 00 ft 6496 k 6496k c \enefcalc\980907 ecw Calculations KW-06016T17Ver50~6;~15-Ju!-1998, Win32" PLUMP ENGINEERING, INC 20101 S W. BIRCH STREET, SUITE 210 NEWPORT BEACH, CA 92660 949-474-2140 FAX 949-474-4240 E-MAIL. PLUMPENG@EARTHLiNK NET Title SMART & FINAL Dsgnr RP Description Scope Job # 980907 Date ev 510001 Description CHECK General Information Center Span 180 Left Cantilever Right Cantilever Single Span Beam Analysis page 1 j SHAER AT SKYLIGHTS - ALONG 00 ft Moment of Inertia ft Elastic Modulus ft Beam End Fixity 160' LENGTH 22' IN FROM END | 1 000 m4 1 ksi Pin-Pin Uniform Loads I On Center Span On Left Cantilever #1 0765 k/ft #1 On Right Cantilever k/n n ^ km Query Values 1 Center Location Moment Shear Deflection 22000ft Left Cant 1,31096 k-ft' " ~- ^1"»'"«»__^ .### ##### inj) 0000 ft Right Cant 0000ft 0 00 k-ft 0 00 k-ft 0 00 k 0 00 k 0 00000 in 0 00000 in (Summary Moments Max + @ Center Max - @ Center @ Left Cant @ Right Cant Maximum = \ 3,098 24 k-ft at 9018ft 000 k-ft at 18000ft 0 00 k-ft 0 00 k-ft 3,098 24 k-ft Shears @Left @ Right Maximum Deflections @ Center @ Left Cant @ Right Cant 6885 k 6885k 6885 k -####### in 0 000 in 0 000 in Reactions @Left @ Right at 9018ft at 0 00 ft at 0 00 ft 6885 k 6885 k f rxf \, >-J (c)"1983-98 ENERCAL'C'c \e~nercalc\980907 ecw Calculations •KW-0601611,"VeT5 0 6ri5-~Julr1998, Win32 PLUMP ENGINEERING, INC 20101 S W BIRCH STREET, SUITE 210 NEWPORT BEACH, CA 92660 949-474-2140 FAX 949-474-4240 E-MAIL. PLUMPENG@EARTHLINK NET Title SMART SPINAL Dsgnr R P Description Scope Job # 980907 Date RBV £10001 General Timber Beam Page 1 I Description CHECK (E) PURLIN FOR NEW MECH UNIT General Information Section Name 4x14 Beam Width 3 500 ' Beam Depth 13250 Member Type Sawn Bm Wt Added to Loads Load Dur Factor 1 250 Beam End Fixity Pin-Pin Wood Density 34 000 Uniform Loads Uniform Loads Over Full Span Center DL Left Cantilever DL Right Cantilever DL Point Loads Dead Load 131 Olbs Live Load Ibs distance 4000ft . . _ Center Span m Left Cantilever |n Right Cantilever 1950 ft ft ft ! Lu 000 ft Lu 000 ft Lu 000 ft Douglas Fir - Larch, No 1 Fb Base Allow Fv Allow Fc Allow Epcf 80 00 #/ft LL #/ft LL #/ft LL Ibs Ibs Ibs Ibs 0 000 ft 0 000 ft 1 ,350 0 psi 85 0 psi 625 0 psi 1,6000 ksi 16000#/ft #/ft #/ft Ibs Ibs 0 000 ft I I Ibs Ibs Ibs Ibs 0 000 ft 0 000 ft 1 Summary I Span= 19 50ft, Beam Width = Max Stress Ratio Maximum Moment Allowable Max Positive Moment Max Negative Moment Max @ Left Support Max @ Right Support Max M allow fb 1.42851 psi Fb 1,687 50 psi Deflections Beam Design OK 3 500m x Depth = 13 25in, Ends are Pin-Pin 0847 1 122k-ft 14 4 k-ft 1219k-ft at 000 k-ft at 000 k-ft 000 k-ft 1440 fv 73 64 ps Fv 10625ps Maximum Shear * 1 9 672 ft 19500ft Reactions LeftDL Right DL Allowable Shear Camber 099k 091 k 5 ©Left @ Right ©Left @ Center @ Right Max Max 34k 49k 255k 247k 0 000 in 0 437 in 0 000 m 255k 247k I Center Span Deflection Location Length/Defl Dead Load -0 291 m 9672ft 8033 TotalJ-oad -0 771 in 9750ft 30360 Left Cantilever Deflection Length/Deft Right Cantilever Dofloction Length/Defl Dead Load 0 000 in 00 0 000 in 00 Total Load 0 000 in 00 0 000 in 00 ENERCALC"c \enercalc\9~80907 ecw Calculations 'KW-06016117VeT5~0~6ri5^Ju1-1998. Win32" PLUMP ENGINEERING, INC. 20101 S Vtf. BIRCH STREET, SUITE 210 NEWPORT BEACH, CA 92660 949-474-2140 FAX 949-474-4240 E-MAIL: PLUWlPENG@EARTHLtNK.NET Title SMART & FINAL Dsgnr RP Description Scope Job # 980907 Date General Timber Beam Page Description CHECK (E) PURLIN FOR NEW MECH UNIT Stress Calcs 1 Bending Analysis Ck 24972 Rb 0000 Sxx Cf 1 000 Max Moment ©Center 12 19 k-ft @ Left Support 0 00 k-ft @ Right Support 0 00 k-ft Shear Analysis @ Left Support Design Shear 3 42 k , Area Required 32 144 m2 Fv Allowable 106 25 psi Bearing @ Supports Max Left Reaction 2 55 k Max Right Reaction 2 47 k j Query Values M, V, & D @ Specified Locations @ Center Span Location = 0 00 @ Right Cant Location = 0 00 @ Left Cant Location = 0 00 102411m3 Area 46 Sxx Req'd 86 69 in3 0 00 m3 0 00 m3 @ Right Support 330k 31 053 in2 106 25 psi * Bearing Length Req'd Bearing Length Req'd Moment ft 000 k-ft ft 000 k-ft ft 000 k-ft 375 in2 Allowable fb 1,68750 psi 1,687 50 psi 1 ,687 50 psi 1 166 in 1 131 in I Shear Deflection 2 55 k 0 0000 in 000k '00000 in 0 00 k 0 0000 in 983-98 ENERCALC c \enercalc\980907 ecw Calculations KW-06016117 Ver5"0"6,"15:3ul:1998. Win32" Title 24 Report for: Smart & Final El Camino Real Carlsbad, CA Project Designer: CMA Company 2501 W Jefferson Blvd Los Angeles, CA 90018 (213)734-4957 Report Prepared By: Solargy, Inc SOLARGY, INC 22028 VENTURA BLVD #207 WOODLAND HILLS, CA91364 (818)347-6096 Job Number: 9031614 Date: 3/18/99 The EnergyPro computer program has been used to perform the calculations summanzed in this compliance report This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 1995 Building Energy Efficiency Standards This program developed by Gabel Dodd/EnergySoft, lie (415) 883-5900 EnergyPro 10 By EnergySoft Job Number 9031614 User Number 1111 ACORD CERTIFICATE OF LIABILITY INSURANCE FAX (619)578-5699PRODUCER(619)578-5200 iross Insurance, Inc 9820 Willow Creek Road San Diego, California , Suite 350 92131-1112 _ ______ THIS CEK" I IHCA I b IS ISiJUbH AS A MA I DATE (MNUODfYY} 06/26/1998 Oh INMJKMA TION - ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW Attn. INSURED Ext Miller and Company, Inc , Marty Miller Construction and Charles Miller, Reneta Miller and Greg Goss 1241 Distribution Way Vista, CA 92083 COMPANY A COMPANY B COMPANYc COMPANY D COMPANIES AFFORDING COVERAGE Golden Eagle Ins- COVERAGES "\\' ' ' THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS EXCLUSIONS AND CONDITIONS OF SUCH POLICIES LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS TYPE OF INSURANCE POLICY NUMBER POLICY EFFECTIVE POLICY EXPIRATION DATE (MM/DD/YY) DATE (MM/DD/YY) „UMIIJ> GENERAL LIABILITY X COMMERCIAL GENERAL LIABILITY CLAIMS MADE X OCCUR A CCP55593400OWNER'S a CONTRACTOR S PROT AUTOMOBILE LIABILITY ANY AUTO ALL OWNED AUTOS X SCHEDULED AUTOS A v CCP55593400X HIRED AUTOS X NON-OWNED AUTOS GARAGE LIABILITY ANY AUTO EXCESS LIABILITY UMBRELLA FORM OTHER THAN UMBRELLA FORM WORKERS COMPENSATION AMD EMPLOYERS' LIABILITY A THE PROPRIETOR/ )NCL NWC31745902 PARTNERS/EXECUTIVE OFFICERS ARE EXCL GENERAL AGGREGATE $ PRODUCTS - COMP/OP AGO $ , ~ „ „ . , ., ,..„„„ PERSONAL a ADV INJURY $04/01/1998 04/01/1999' ' EACH OCCURRENCE S FfRE DAMAGE (Any one fire) $ MED EXP (Any one person) S COMBINED SINGLE LIMIT S BODILY INJURY $(Per person) 04/01/1998 04/01/1999 BODILY INJURY $(Per acciden<! PROPERTY DAMAGE S AUTO ONLY EA ACCIDENT S OTHER THAN AUTO ONLY EACH ACCIDENT $ AGGREGATE $ EACH OCCURRENCE S AGGREGATE $ $ TORY LIMITS ER EL EACH ACCIDENT $ 06/29/1998 06/29/1999' ' EL DISEASE - POLICY LIMIT $ EL DISEASE - EA EMPLOYEE $ 2,000, 2 , 000 , 1,000, 1,000, 50, 5, 1,000, 1,000, 1,000, 1,000, OOC ooc ooc ooc ooc ooc ooc 00( ooc 00( DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES/SPECIAL ITEMS LO days notice for non-payment Cert holder only CEHTIFtCATE rtOLpgR Contractors State License Board P 0 Box 26000 Sacramento, CA 95826 ACORD 25-5(1/95); CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING COMPANY WILL ENDEAVOR TO MAIL _3Q_ DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO MAIL SUCH NOTICE SHALL IMPOSE MO OBLIGATION OR LIABILITY OF AJIY KJND UPON THE COMPANY, ITS ACENTS OR REPRESENTATIVES AUTH0«£ED REPRESENTATIVE <^_Z-- / /x/j / I S {J L -S-JfsttfA J? ^ ^^~^^t-^^^ \ ~^T--^ ^?Z~^ ©ACORO CORPORATION t91 \ /I Si