Loading...
HomeMy WebLinkAbout2622 La Costa Ave; ; CBR2019-0256; PermitResidential Permit Print Date: 10/30/2019 Job Address: Permit Type: 2622 La Costa Ave BLDG-Residential 2162800400 $20,611.00 Work Class: Addition Parcel No: Lot#: Valuation: Reference #: Occupancy Group: Construction Type: # Dwelling Units: Bathrooms: Bedrooms: Orig. Plan Check#: Plan Check#: Project Title: Description: WEBB: 53 SF ADDITION & 250 SF REMODEL AT KITCHEN Applicant: Owner: TOM KING 34661 Apache Dr Julian, CA 92036-9506 619-733-3796 TRUST WEBB FAMILY TRUST 03-12-09 2622 La Costa Ave BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) CARLSBAD,CA 92009 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1-MEDIUM Total Fees: $972.98 Total Payments To Date: $972.98 Ccityof Carlsbad Permit No: CBR2019-0256 Status: Applied: Issued: Permit Fina led: Closed -Finaled 01/31/2019 03/15/2019 Inspector: CRenf Final Inspection: 10/30/2019 12:52:44P Balance Due: $0.00 $212.53 $148.77 $41.00 $175.00 $39.00 $49.00 $1.00 $2.68 $246.00 $58.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as ''.fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov {"city of Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan Chee• Cf£? Ql9-()2S(o Est. Value 2D1U>\\-· PC Deposit -~------- Date __,_\ -__._'.3_,_\._-_· \._q__.___ Job Address ~ 2-2 I..,.. GoS"'IA ,6416 . Suite: ___ APN: '2. I<. • -Z.e,t) • 0 4-oo CT/Project#: Lot#: Fire Sprinklers: yes@ Air Conditioning(S)no BRIEF DESCRIPTION OF WDRK: __,+_,S~J,c_S"-ll,r-''--'~=l.!;,..=14,_.se.,~c:::O.!..t-(..:..__J-1"'-.!:~"""'=--~°"""'=---""f<f'----'e-,,t..,_.."'j.._1~. --- 18-rc.•~ I 614 I-S"t"oi'-'< Sf=:P- )'ll Addition/New: -t-1$2 Living SF, ___ Deck SF, ___ Patio SF, ___ Garage SF Is this to create an Accessory Dwelling Unit? Yes I@ New Fireplace? Yes ,0 if yes how many? __ ~ Remodel: ,Z.50 SF of affected area Is the area a conversion or change of use? Yes<!§) □ Pool/Spa: ____ SF Additional Gas or Electrical Features? ____________ _ □ Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground, Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No Panel Upgrade: Yes/ No D Reroof: _____________________________________ _ D Plumbing/Mechanical/Electrical Only: ________________________ _ □ Other: _________________________________ _ APPLICA?~RIMARYI/ PROPERTY OWNER Name: =-\-0"1 E-tt:J4 Name: \,,,\.-.<("\-' Wc,-l:>b Address: 14,<.<. I Af~ 12"::. Address: '2,(o1,,'L I-A ~s::r-k). City: JtAt.~ State:~Zip: 4~?1"' City: G.Af➔.4""9c? State:~Zip: 'ffA:,C\ Phone: l.oJ~•:111.•1.1~ Phone: Email: +;i;.; .. ; . .w.u·ije5Mf1'1I. y~mail: _______________ _ DESIGN PROFESSIONAL CONTRACTOR BUSINESS Name: _________________ _ Name: ___________________ _ Address: ________________ _ Address: _________________ _ City: _______ State: ___ Zip: ___ _ City: _______ State: ___ Zip: ______ _ Phone: ________________ _ Phone: ___________________ _ Email: _________________ _ Email: ___________________ _ Architect State License: ___________ _ State License: ______ Bus. License: ______ _ (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.S by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-1 Page 1 of2 Rev. 06/18 ,, ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: □ I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. DI have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: _____________________ _ Policy No. ______________ Expiration Date: __________ _ □ Certificate of Exemption: I certify that in the periormance of the work for which this permit is issued, I shalt not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage ls unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the labor Code, interest and attorney's fees. CONTRACTOR SIGNATURE: □AGENT DATE: -------------------------- ( OPTION B ): OWNER-BUILDER DECLARATION: I h reby affirm that I am exempt from Contractor's License Law for the following reason: as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. , Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). □ I, as owner of the property, am eKclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). □ I am eKempt under Section ________ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes O No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, b ntracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work): OWNER SIGNATURE: DATE: 1.11 • 1,0 • I'\ CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: _____________________ Lender's Address: ____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes O No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes O No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). APPLICANT SIGNATURE: ~~ ll Je,Q.b DATE: ~3-+=( {5'-++-(1 q __ 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-1 Page 2 of2 Rev. 06/18 PERMIT INSPECTION HISTORY REPORT (CBR2019-0256) Permit Type: BLDG-Residential Application Date: 01/31/2019 Owner: Work Class: Addition Issue Date: 03/15/2019 Subdivision: Status: Closed -Finaled Expiration Date: 12/23/2019 Address: IVR Number: 16819 ' Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-Building Deficiency BLDG-17 Interior Lath-Drywall BLDG-18 Exterior Lath and Drywall BLDG-23 Gas-Test-Repairs 06/19/2019 06/19/2019 BLDG-18 Exterior 095187-2019 Lath/Drywall Checklist Item BLDG-Building Deficiency 06/26/2019 06/26/2019 BLDG-23 Gas/Test/Repairs 095663-2019 10/30/2019 10/30/2019 BLDG-Final Inspection October 30, 2019 Checklist Item BLDG-Building Deficiency 109202-2019 Checklist Item BLOG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS Passed Chris Renfro COMMENTS Passed Chris Renfro COMMENTS Passed Chris Renfro COMMENTS TRUST WEBB FAMILY TRUST 03-12-09 LA COSTA SOUTH #5 2622 La Costa Ave Carlsbad, CA 92009-7324 Reinspection Complete Passed No No No No Complete Passed Yes Complete Passed Yes Complete Passed Yes Yes Yes Yes Yes Page 2 of 2 PERMIT INSPECTION HISTORY REPORT (CBR2019-0256) Permit Type: BLDG-Residential Application Date: 01/31/2019 Owner: Work Class: Addition Issue Date: 03/15/2019 Subdivision: Status: Closed -Finaled Expiration Date: 12/23/2019 Address: IVR Number: 16819 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 03/18/2019 03/18/2019 BLDG-SW-Pre-Con 086349-2019 Checklist Item BLDG-Building Deficiency 03/27/2019 03/27/2019 BLDG-11 Foundation/Fig/Pier s (Rebar) 087114-2019 Checklist Item BLDG-Building Deficiency 05/02/2019 05/02/2019 BLDG-14 090631-2019 05/28/2019 Frame/Steel/Bolting/ Welding (Decks) Checklist Item BLDG-Building Deficiency BLDG-15 090632-2019 Roof/ReRoof (Patio) Checklist Item BLDG-Building Deficiency BLDG-24 Rough/Topout 092953-2019 Checklist Item 05/30/2019 05/30/2019 BLDG-21 BLDG-Building Deficiency 093391-2019 Underground/Underf loor Plumbing Checklist Item BLDG-Building Deficiency 06/04/2019 06/04/2019 BLDG-84 Rough 093679-2019 Combo(14,24,34,44) Checklist Item BLDG-Building Deficiency BLDG-14 Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout BLDG-34 Rough Electrical BLDG-44 Rough-Ducts-Dampers 06/17/2019 06/17/2019 BLDG-82 Drywall, 094784-2019 Exterior Lath, Gas Test, Hot Mop October 30, 2019 Passed Chris Renfro COMMENTS Passed Chris Renfro COMMENTS Failed Tim Frazee COMMENTS Passed Tim Frazee COMMENTS Roof shoaling nailing OK 5/2/19 Failed Chris Renfro COMMENTS Not ready Passed Chris Renfro COMMENTS Passed Chris Renfro COMMENTS Cancelled Chris Renfro TRUST WEBB FAMILY TRUST 03-12-09 LA COSTA SOUTH #5 2622 La Costa Ave Carlsbad, CA 92009-7324 Reinspection Complete Complete Passed Yes Complete Passed Yes Reinspection Complete Passed No Complete Passed Yes Reinspection Complete Passed No Complete Passed Yes Complete Passed Yes Yes Yes Yes Yes Reinspection Complete Page 1 of 2 Ghostrider inc.RECORD COPY PH. 760-473-5052 Fax 619-367-5791 Any Where Any Time Around the World, Around the Clock P.O. Box 1120 Fallbrook, CA 92088 E-mail, ghostriderinc@hotmail.com E-mail, twghostrider01@yahoo.com --.... -~ --.-.,,----, ,..,-... --- ~.., <' -;\.,~ ~ ..... .,. ',., t-~-.,,.. J,.-. "~'r , .... fk.• _ __,._ • ·• •"" 'J,; Freddie & Marlyn Webb c·ty PROJECT Webb Kitchen 3/26/2019 I of Carfsbad,RESS 2622 La Costa Avenue CLIENT DATE ARCHITECT Tom King Architectur: MAR 2 7 lOlg CITY Carlsbad, CA 92009 34661 Apache Dr. Julian, ca 92036 Jos# Ghostrider, Inc. ENGINEER PQE Inc. Matt McPherson BUILDING D/V/S/~ILDING PERMIT/DsA/osHPD# CBR2019-0256 13484 Appalachian Way San Diego, Ca 92129 PLAN FILE# 579859 CONTRACTOR Sch earing Construction mike@schearing.com w. o. # Not Applicable INSPECTION SAMPLES QTY. MATERIAL DESCRIPTION CHECKLIST Epoxy All-thread Epoxy Doweling Concrete, PSI: # Unknown/Existing Epoxy Type: # Simpson SET-XP (ESR 2508) Batch Number: # 1000028968, Exp. 12/2020 Threaded-Rod: # 5/8" Dia. (Galv.) Rebar: Gr/Type: # A-615/Grade 60 Approved Plans Available Compressed Air Blow,Brush,Blow Bottle Brush Nylon 1/2" Dia. Edge Distance Approved Weather Sunny Bright Safety Gear: Hardhats,Glasse~ REMARKS: Inspected epoxy all-thread of added (8) anchor bolts on project as shown on approved drawings (S1). Contractor used 5/8" Dia. (Galv.) all-thread. Contractor drilled¾" Dia. X 7" deep holes for anchor bolts. Inspected epoxy doweling into existing concrete at new to existing footing intersections & slab-on-grade sections. Contractor installed (2) top & (2) bottom bars at footing intersections. Contractor used #4 bars. Contractor drilled 5/8" Dia. X 6" for rebar doweling. Contractor used clean dry compressed air & a nylon bottle brush to clean all holes. Holes were filled and rods installed. Work on project is ongoing. CERT/FICA TION OF COMPUANCE: To the best of our knowledge, oil of the reported work, unless otherwise noted, substontlally complies with approved plans, specifications and applicable sections of the building codes. For this report to be valid it must have a final report, signed by the special inspector, stating "Final Report of inspection and material testing". Without a final report this document Is Invalid. This report covers the locations of the work reported only and doesn't constitute engineering opinion or project control. ITimein Time out: Authorization: _..,_T""'H=E-=D:;.::E:..:.P..:U:....:TYc..:...:::S _______ _ Signature __ ~--"'~--~--· __ _ Taylor White A. W.S. & I.C.C. & San Diego 1287: This Is not o government form. The Federol, State. County ond City seals only signify thot inspections ore conducted under Ee<terol. State. County ond City Codes 12013, c.s.c.1. This document Is not used for odvertislng, morketing or promotions. This document Is used to convey comolionce with the Codes. Ghostrider, Inc. 01-2008. Rev. (18) 9/2015 ✓• EsG1I A SAFEbt:1lt Company DATE: Mar. 11, 2019 JURISDICTION: Carlsbad □ APPLICANT ~URIS PLAN CHECK#.: CBR2019-0256 SET: II PROJECT ADDRESS: 2622 La Costa Avenue PROJECT NAME: Webb Residence Kitchen Remodel & 53 SF Addition □ □ □ □ □ [8J □ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Tom King EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: ~ Telephone#: (619) 733-3796 Date contacted: -Cot;J~) Email: tomking.design@gmail.comj Mail Telephone Fax In Person · REMARKS: Change has been made to sheet S2 and clouded/~ 11 ~~ make change to all other plan sets. \J1/ By: Chris Shaver Enclosures: EsGil 3/4/2019 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 DATE: Feb. 11, 2019 JURISDICTION: Carlsbad PLAN CHECK#.: CBR2019-0256 ✓• EsG1I A SAFEl)uilfCompany SET: I PROJECT ADDRESS: 2622 La Costa Avenue □ APPLICANT D JURIS. PROJECT NAME: Webb Residence Kitchen Remodel & 53 SF Addition D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. IZ] The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. IZ] The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: Tom King IZ] EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Tom King Telephone#: (619) 733-3796 Date contacted: (by: ) Email: tomking.design@gmail.com Mail Telephone 0 REMARKS: By: Chris Shaver EsGil Fax In Person Enclosures: 2/4/2019 9320 Chesapeake Drive, Suite 208 ♦ Sau Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBR2019-0256 Feb. 11, 2019 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CBR2019-0256 JURISDICTION: Carlsbad PROJECT ADDRESS: 2622 La Costa Avenue FLOOR AREA: Addition = 53 SF Remodel = 250 SF REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 1/31/2019 DATE INITIAL PLAN REVIEW COMPLETED: Feb. 11, 2019 FOREWORD (PLEASE READ): STORIES: 1 HEIGHT: -11 FT DATE PLANS RECEIVED BY ESGIL CORPORATION: 2/4/2019 PLAN REVIEWER: Chris Shaver This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBR2019-0256 Feb. 11, 2019 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Chris Shaver PLAN CHECK#.: CBR2019-0256 DATE: Feb. 11, 2019 BUILDING ADDRESS: 2622 La Costa Avenue BUILDING OCCUPANCY: R3 BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Addition/Remodel City Estimate Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance 1997 UBC Buildin g Permit Fee i ... l I 1997 UBC Plan Check Fee [~ Type of Review: P" Complete Review Reg. VALUE Mod. r Structural Only ,. r Repetitive Fee I• Repeats .. ,. r Other r Hourly EsGil Fee ,. ~Hr.@• Comments: ($) 20,611 20,611 $129.427 Sheet 1 of 1 Carlsbad CBR2019-0256 Feb. 11, 2019 PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring JJf1S)_ corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). This will be verified on each submittal. 3. Plans deviating from conventional wood frame construction shall have the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations. (California Business and Professions Code). This will be verified on each submittal. FIRE PROTECTION 4. Show locations of permanently wired smoke alarms with battery backup, per Section R314: Please show locations on the plans. a) Inside each bedroom. b) Outside each separate sleeping area in the immediate vicinity of the bedrooms. c) On each story, including basements. d) Such smoke alarm locations shall comply with the following: i) They shall be not less than 3' from the door opening of a bathroom. ii) They shall be at least 20' from a cooking appliance. iii) They shall be at least 3' from supply registers of heating/cooling systems. iv) They shall be at least 3' from the tip of the blade of a ceiling- mounted fan. • NOTE: When more than one smoke alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the unit. Carlsbad CBR2019-0256 Feb. 11, 2019 5. In existing buildings, when alterations, repairs or additions requiring a permit occur (or when one or more sleeping rooms are added), the dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarms shall be interconnected and hard wired. Exception: Smoke alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R314.8.1. 6. In dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), show the locations of permanently wired carbon monoxide alarms with battery backup, per Section R315: Please show locations on the plans. a) Outside each separate sleeping area in the immediate vicinity of the bedrooms. b) On each story, including basements. • NOTE: When more than one carbon monoxide alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the unit. 7. When alterations, repairs or additions are proposed for dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), the dwelling unit shall be provided with carbon monoxide alarms located as required for new dwellings; the carbon monoxide alarms shall be interconnected and hard wired. Exception: Carbon monoxide alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R315.2. GENERAL RESIDENTIAL REQUIREMENTS 8. Glazing in the following locations should be shown on the plans as safety glazing material in accordance with Section R308.4: a) Glazing in doors. b} Glazing adjacent to a door where the nearest vertical edge of the glazing is within a 24" arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60" above the walking surface. Exceptions: i) Glazing in walls on the latch side of and perpendicular to the plane of the door in a closed position. ii) Glazing in walls on the push side of and perpendicular to the plane of the door in a closed position (hinge side). iii) Glazing that is adjacent to the fixed panel of patio doors. Carlsbad CBR2019-0256 Feb. 11, 2019 EXITS, STAIRWAYS, AND RAILINGS 9. Please show landings at exterior doors. There shall be a landing or floor on each side of each exterior door. The width of each landing shall not be less than the door served and have a minimum or 36-inches measured in the direction of travel. Exterior landings shall be permitted to have a slope not to exceed ¼-inch per foot. Landings or finished floors shall not be more than 1.5 inches lower than the top of the threshold for outward swinging exterior doors or 7. 75" for doors that do not swing outwards. R311.3. ROOFS/DECKS/BALCONIES 10. Show the required ventilation for attics (or enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters). The minimum vent area is 1/150 of attic area (or 1/300 of attic area if at least 40% (but not more than 50%) of the required vent is located no more than 3' below the ridge). Show on the plans the area required and area provided. Section R806.2. a) When using a radiant barrier, California energy design affects the attic ventilation area requirement: If using the Prescriptive method for energy compliance, then the attic vent area must be at the 1/150 area: If using the Performance method, either the 150 or 300 areas may be used, as documented on the energy forms. Section RA4.2.1. 11. Enclosed rafter spaces do not require venting if the following specific insulation design is used, per Sections R806.5/EM3.9.6: ♦ If the insulation is air-permeable and it is installed directly below the roof sheathing with rigid board or sheet insulation with a minimum R-4 value installed above the roof sheathing. (or) ♦ If the insulation is air-impermeable and it is in direct contact with the underside of the roof sheathing. (or) ♦ If two layers of insulation are installed below the roof sheathing: An air- impermeable layer in direct contact with the underside of the roof sheathing and an additional layer of air permeable insulation installed directly under the air- impermeable insulation. 12. Where eave vents are installed, insulation shall not block the free flow of air. A minimum of 1" of air space shall be provided between the insulation and the roof sheathing. To accommodate the thickness of insulation plus the required 1" clearance, member sizes may have to be increased for rafter-ceiling joists. Section R806.3. 13. Note on the plans: "Attic ventilation openings shall be covered with corrosion-resistant metal mesh with 1/16" minimum to¼" maximum openings. Section R806.1. Carlsbad CBR2019-0256 Feb. 11, 2019 STRUCTURAL 14. Please provide a shear wall schedule for the new construction. 15. Please coordinate the wall section on sheet A-3 with the structural sheets. This section shows 4x8 rafters at 4' o.c. 16. Please clarify the reflected ceiling plan on sheet A-2. This section shows 6x6 beams, which are not shown on the structural sheets. If these beams are being proposed, please include them on the structural sheets and included details showing the connection to the framing. ELECTRICAL 17. Note on the plans that receptacle outlet locations will comply with CEC Article 210.52. 18. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all receptacles in a dwelling). b) Weather resistant type for receptacles installed in damp or wet locations (outside). c) Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.12(A): Kitchens, laundry areas, family, living, bedrooms, dining, halls, etc. d) GFCI protected outlets for locations described in NEC 210.8(A): Laundry areas, kitchen dishwashers, kitchens, garages, bathrooms, outdoors, within 6' of a sink, etc. 19. Show at least one wall switch-controlled lighting outlet to be installed in every habitable room; in bathrooms, hallways, stairways, attached garages, and detached garages with electric power; and at the exterior side of outdoor entrances or exits. At interior stairways show 3-way switching for lighting outlets at each floor level where there are six or more steps. CEC Article 210.70(A). PLUMBING 20. Specify on the plans: Water conserving fixtures: New water closets shall use no more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8 GPM, lavatories are limited to 1.2 GPM, and showerheads may not exceed 1.8 GPM of flow. CPC Sections 407, 408, 411, 412. Carlsbad CBR2019-0256 Feb. 11, 2019 21. Specify on the plans whether the existing house was built before or after 1994. For additions or improvements to a residence built before 1994, note on the plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons of water per flush, urinals that use more than one gallon of water per flush, showerheads that have a flow capacity of more than 2.5 gallons of water per minute, and interior faucets that emit more than 2.2 gallons of water per minute) shall be replaced. Certification of compliance shall be given to the building inspector prior to final permit approval. California SB407. RESIDENTIAL GREEN BUILDING STANDARDS Please update notes: 22. Indoor water use. Show compliance with the following table, per CGC Section 4.303.1. FIXTURE FLOW RATES FIXTURE TYPE MAXIMUM FLOW RATE Water closets 1.28 gallons/flush Urinals (wall-mounted) 0.125 gallon/flush Urinals (others) 0.5 gallon/flush Showerheads 1.8 gpm@ 80 psi Lavatory faucets 1.2 gpm @ 60 psi1 Kitchen faucets 1.8 gpm @60 psi Metering faucets 0.25 gallons per cycle 1. Lavatory faucets shall not have a flow rate less than 0.8 gpm at 20 psi. 23. Note on the plans that when a shower is provided with multiple shower heads, the sum of flow to all the heads shall not exceed 1.8 gpm @ 80 psi, or the shower shall be designed so that only one head is on at a time. CGC Section 4.303.1.3.2. 24. Recycling. Note on the plans that a minimum of 65% of construction waste is to be recycled. CGC Section 4.408.1. ENERGY CONSERVATION 25. All domestic hot water piping to have the following minimum insulation installed: ½" pipe (1/2" insulation);¾" pipe (1" insulation); 1" to 1-½" pipe (1-½" insulation). CPC 609.11 & ES 150.00) a) Additionally, the ½" hot water pipe to the kitchen sink, and the cold water pipe within 5' of the water heater both require 1" minimum insulation. ES 150.00) Carlsbad CBR2019-0256 Feb.11,2019 Residential Energy Lighting Requirements: ES 150.0(k) 26. All installed luminaires shall be high-efficacy in accordance with ES TABLE 150.0-A. Light sources that are not marked "JA8-2016-E" shall not be installed in enclosed luminaires. ES 150.0(k) 27. Dimmers or vacancy sensors shall control all LED style luminaires. Two exceptions: Fixtures installed in hallways or (closets under 70 square feet). 28. Recessed can light fixtures shall be IC listed, air-tight labeled, and not be equipped with a standard medium base screw shell lamp holder. ES 150.0(k) 29. SFD outdoor lighting fixtures that are attached to a building are required to be high efficacy, be manually on/off switch controlled, and have both motion sensor and photocell control. See ES 150.0(k) 3 for additional control options. Residential ventilation requirements: ES 150.0(o)/ASHRAE 62.2 30. Kitchens require exhaust fans with a minimum 100 cfm ducted to the exterior. Detail compliance by including a complying exhaust fan or a ducted range hood to the exterior. a) All fans installed to meet all of the preceding ventilation requirements must be specified at a noise rating of a maximum 1 "Sane" (continuous use) or 3 "Sane" (intermittent). MISCELLANEOUS 31. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 32. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 33. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chris Shaver at EsGil. Thank you. STORM WATER COMPLIANCE FORM Rr.::-•· 'JED TIER 1 CONSTRUCTION SWPPP . J 1 2019 CB ~2019-·025l.p E-29 _;F CARLS,:: . SW - STORM WATER POLLUTION PREVENTION NOTES BEST MANAGEMENT PRACTICES (BMP) SELECTION TABCE ". -LJI' Erosion Control Sediment Control BMPs Tracking Non-Storm Water Waste Management and Materials 1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE BMPs Control BMPs Management BMPs Pollution Control BMPs AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION C -OF EROSION AND SEDIMENT CONTROL BMPs WHEN RAIN C C .!2 -.!2 .!2 -C C .., --O> 0 " .., " .., IS EMINENT. ., C u u C C O> E C ~ C -0 -" " 0 'o ·.:: .Q. 0 0 0 E L L :;:; L ., :::,; 'O ., O' L " --·E ' " >, O> -., 2. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION C a, L ,,; " £ ., ., ., 0 er L 0 .§ ., O> a. " ·.:: C a, C > L u.J " 0 -Best Management Practice* ~ 0 0 0 a. L to " > C ., ,,; [I] L 0 ., 8 " " 0 --3::-o-CONTROL DEVICES TO WORKING ORDER TO THE SA Tl SF ACTION ii ., '" ., L " 0 C UL ., i .., w C a, C C 3:: ~ C I-E ., :::,; (BMP) Description ➔ ., "en ·e 1l ., O> " O> [I] ·c c: O> C .., ., C Cl ::, !!! -" ., " OF THE CITY INSPECTOR AFTER EACH RUN-OFF PRODUCING " -;; ~ Q) -0 0 ;o C LO ~~ 'O >, 0 ., CC 0 O> " l3 E " E " E ~ C Cl 0 [I] en·-O> O:;:; u 1l Co " RAINFALL. :::,; Cl o, Cl C " a: E 0 N a, :!: 0 o,:.:: " a, C 0" 0 ~ ct e 3:: ., 0 ., -., X 0 ~ .>< -" ..c E~ ;:: fil =3: ~:;:; :0 o·c ·-O> 'ii O> 'O O' " O> $ ,!; j C 0 L 0 g 6 0 b o 'O ,.:; C " u L ., " 'O ·-.., 0 Q) L --'O 0 0 0 t:: ·a g. 'O " " " u C 515 ..CL ..c 0 bg ·s; ~ -·-0 -o -= C: •-C NC CC THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION -~ 0 O> .So ..:; " 3. ~ ~ CL = " ..:; ~ ~o 0 -L -c 3:: a: 09 0 ~[5 o_ 0 -a. 0 oO 0 0 0 0 u.J Cl vi en en u en> en en a.. en_ ena: 0..0 0.. :::,; en :::,; en enu en:::,; :r: :::,; u:::,; CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR CASQA Designation ➔ .... a N ...., r--CX) N ...., .... "' "' CX) r--CX) en 'T -...., "' "' r--CX) 'T 'T 'T I I I I I I I I I I I I I I I I I I I I I UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. u u u u u.J u.J u.J u.J u.J ~ u.J u.J fl" fl" en en en en i i i i i i i Construction Activity u.J u.J u.J u.J en en en en en en en z z z z 4. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE Gradina/Soil Disturbance AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) ~ Trenchina /Excavation V" DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT )( Stockoilina '>t' ')(_ ( 40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER Drillinn IBorina EACH RAINFALL. Concrete/Asohalt Sawcuttina 5. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM Concrete Flatwork Pavina AGGREGATE. Condui\/Pioe Installation 6. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER ")j Stucco/Mortar Work PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST .,. Waste Disoosal ,;:,c;;: BE INSTALLED AND MAINTAINED. Staainn/1 av Down Area Eauioment Maintenance and Fuelina 7. THE CITY INSPECTOR SHALL HA VE THE AUTHORITY TO ALTER X Hazardous Substance Use/Storaae -THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED Dewaterina TO ENSURE COMPLIANCE ~TH CITY STORM WATER QUALITY Site Access Across Dirt REGULATIONS. Other (list l: Instructions: 1. Check the box to the left of all applicable construction activity (first column) expected to occur during construction. 2. Located along the top of the BMP Tobie is a list of BMP's with it's corres~onding California Stormwoter Quality Association (CASQA) designation number. Choose one or more BMPs you intend to use during construction from the list. Check he box where the chosen activity row intersects with the BMP column. 3. Refer to the CASQA construction handbook for information and details of the chosen BMPs and how to apply them to the project. OWNER'S CERTIFICATE: I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION PROJECT INFORMATION ACTIV1TIES TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID Site Address: ~ ,z_ t-C..s~~. THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO SHOW THE LOCATIONS OF ALL CHOSEN BMPs ABOVE AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCTION '2.lt. .1,~o • i~o RELATED POULUTANTS; AND (2) ADHERE TO, AND AT AUL TIMES, ON THE PROJECTS SITE PLAN/EROSION CONTROL PLAN. Assessor's Parcel Number: COMPLY 1'11TH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP SEE THE REVERSE SIDE OF THIS SHEET FOR A SAMPLE THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIV1TIES EROSION CONTROL PLAN. Emergency Contact: lk'l,bk UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED Nome: H-.,,J..,..,._ BY THE CITY OF CARLSBAD. t o~~'"~••D 24 Hour Phone: 9<;;!2 ,::J'.?i'S ,"t:'14_f> Construction Threat to Storm Water Quality ---------A <ll• 'O· lj (Check.% 0~//lfflNER S AGENT NAME (SIGNATURE) DATE EDIUM □ LOW E-29 Page 1 of 1 REV 02/16 State of California County of San Diego ) A notary public or other officer completing this certificate verifies only the identity of the individual who signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validity of that document. On JO..AlAWf 2 tf , ~1$; before me, Kathleen M. Schearing the undersigned Notary Public, personally appeared [Y\a,,-\y h (,.Je,k.b , who proved to me on the basis of satisfactory evidence to be the person whose name is subscribed to the within instrument and acknowledged to me that he executed the same in his authorized capacity, and that by his signature on the instrument the person, or the entity upon behalf of which the person acted, executed the instrument. I certify under PENALTY of PERJURY under the laws of the State of California that the foregoing paragraph is true and correct. WITNESS my hand and official seal. Signature wf #/JJ Notary Public KATHLEEN M. SCHEARING ( COMM. #2103584 z Notary Public • California ~ San Diego County ~ M Comm. Ex ires Mar. 17, 2019 (Seal)