Loading...
HomeMy WebLinkAbout2624 OBELISCO PL; ; CB152882; PermitCity of Carlsbad 16,35 Faraday,~v - Carlsbad, dA 92008 03'-23-2016. Res'identiall Pdrmit Permit No: CB 152882 Building Inspection Request Line (760) 602-2725 Job Address: 2624 OBELISCO PL CBAD Permit Type: RESDNTL' Sub Type: RAD Status: ISSUED Parcel No: 2154602600 Lot* - 0 Applied: 09/02/2015 Valuation: -$40,942.00- Constuction Typ6'. 58 Entered By: JMA p Occupancy Group: Reference #: Plan Approved: 03/23/2016 #Dwelling Units: 0 Structure-Type: Issued:-03/23/2016 Bedrooms: 0 Bathrooms: 0 inspect Area: Orig PC#: Plan Check #: Project Title: KAALEWICZ:171SFlST&2NDFLR 135 SF REMODEL ENLARGING KITCHEN, ADD BATHROOM, 256 SF PATIO COVER Applicant: Owner: TRAVIS, DEAL MALEWICZ FAMILY TRUST 06-26~87 STE, 108 300 CARLSBAD VILLAGE DR 2624 OBELISCO PL CARLSBAD CA 92008-2990 CARLSBAD CA 92009 760-893-9055 Building Permit Add'I Building Permit Fee .$348.89 Me ' te r Size 'Add'I Recl. Water Con. Fee $0.00 Plan Check $244.22 Meter Fee $0.00 Addl Plan Check Fee '$0.00 SDCWA Fee - $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee .$5.32 PFF (3105540) $0.00 Park in Lieu Fee $0.00,- PFF:(4305540) $0.00 Park Fee $0.00 License Tax (3104193) - $0.00 LFM Fee $0.00 License T~x (4304193) $0.00 Bridge Fee $0.00 Traffic Impact Fee (3105541) $0.00 Other Bridge Fee $0.00. Traffic Impact Fee (4305541) $0.00 BTD #2 Fee .$0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL $59'00 RenewalFee $0.00 ELECTRICAL TOTAL $46.00 Add'I Renewal Fee $0.00 MECHANICAL TOTAL $51.83 Other Building Fee $0.00 Housing Impact Fee $0.00 HMP Fee $0.00 Ho6si'ng InLieu Fee $0.00 Pot. Water Con. Fee. $0.00 Housing Credit Fee $0.00. Meter Size Master Drainage Fee $0.00 Ac1d'I Pot. Water Con.'Fee $0.00 Sewer Fee $0.00 Recl. Water Con. Fee $0.00 Additional Fees $0.00 Gr6en 'Bldg Stands (SB1473) Fee $2.00 Fire Sprinkler Fees ..-Green Bldg,Stands Plan Chk Fee $0.00, -TOTAL PERMIT'FEES $757.26 Total Fees:- $757.26 Total Payments to Date:, $15T26 Balance Due: $0.00 FINAL.APPR VAL Inspector: Date: bearance: -7-7 WMCE Please take NOME that approM of ywr pqect include, the "In,~siticdlcif fees, dedications, reservations, or other exactions herBeer collectively referredtoas'fees/exactions." You have 90 days frornthedate this perrnit was iswed to protest inposition of these feestexactions. If you protest them you rrust !cllavv the protest procedures set forth in Gaverrin-ient Code Section 660na), and file the protest and any other reqLi red inforrration with the City N/lanager for- process ng in accordance with C.Msbad Kkinici pal Code Section 3.32 030. Falure to tirriely follow that procedure will bar arty sibsegient legal action to attack remew, set aside, void, or annul their inposition.. You are hereby FILIRMEIR NO-n R ED that your right to protest t1he specified fees/exactions; DOES NOT APPLY to water and saw connection fees and capacity changes, nor planning, zoning, gradirij or other sinilar application prooessing or service fees in conne~ticn Wth thisiprPiect. NOR DOES ITAPPLYto any I fees/exactions of which you have orWously been dven a NCMCE sirrilar tothis, or astovhich the stakite of limitations has pLxviouslycitherwise e)dred .0 I City'of Carlsbad , 1,635 Faraday Av Carlsbad,.CA 92008 Storm. Water PollUtionPreventioh -Pla' o) Permit ri (SWPP 03"28~2016 -Ree.mit Nb:S,Wl 503,39 Job Address: 2624,OBELISCO P L CBAD Permit Type:' SWPPP Status: ISSUED Parcel No:. 215460,2600 Lot 0 Applied: 09/0V20151 R'dfe r6hce,#: Entered By: JMA CB#: CB152882 Issued' -03/23/2016 Inspect Area: Project Title: -MALEWICZ:'l 71 SF ADDITION Tier: 1 Priority:. M Applicant: Owner TRAVIS DEAL MALEWicz FAMILY TRUST 0646-87 2624 OBELISCO PL CARLSB'AD'CA 92009. 760-'893-9055 Eme'rgency, Contact- MARYANN MALEWICZ 760-931'-0426 SWPPP Plan Check. $54.00 SWPPP,Insp6c ' tions $228.00 Additional Fees' $0.00 TOTAL PERMIT FELS $282.00 Total Tees:, $282.00 7, Total Payments To Date: $282.00 Balance Due: $0.00 Appum&%VAL FINAL KU CL- E 7 'EARANC DATE ----------- SIGNATURE P MFIRE :OHEA -1 HAZM LTH' THE Fql..L~WfNG APPROVALS REQUIRED PRIOR TO PERMIT ISSUA CE:.,~D LA,NNING' ',DEN'GINEERING'' G anZ,he—, 'p1icdti6h-.' P, Blididi Per'Mit-A0 Ck 1635 Faraday`Avi X92008 -."Cl, .0 e.,-Car`lsbi~d', C-~'kt ~:Ph: 760-602~27,19` Fix.. 601602-~8558,. Plait, Ck.. U6 6 ft, 6mail '66ild. I- P S cars a ca.gov ing Uff. gOV carMidciii WWW. Date' WPPP, SU1TE#/SPACE#/UNIT# ]~PN- JOB;ADDRESS. 2_1 PHAS I# 9~ UNITS [# BEDROO MS # BATHROOMS' 'OCC. GRO UP TCT/PROJECT # LOT it TENANT BUSINESS NAMEf Fo-~tl F DESCRIPTION OF WORK: Include Square Feet~o?f, Areals) . .. ... lc~. . AXL-4), A]' *J tiib A'' A&V, J_- EXISTIWUSE~ ~-~`JGARAGE (SF), PATIOS (SF DECKS~JSF) FIF~PLA~E,~' '~,JAIR ON~NGr I ~IRE SPRINKLERS' PROPOSED UsE qONDITI [J'IYES I NO .-Y s WE] f - E APPLICANT NAME PROPERTYOWNER' P 'ar~ 'Ilionta-ct, WIA ilm y —1t7i J/C-z ADDRESS", ADDRESS 0 A Uk aNim— C MAD %STATE, - CITY STATE;, '7 ZIP - —f. CITY cil — Ck - PHONE"' FAX PHONE FAX 4_4 7 EMAIL EMAIL, J: DESIGN PROFESSIONALr_ CONTRACTOR BUS. NAME A S,AiAL N6"" twe ADDRESS ODRESSI 'd e4y 3 , C (I - Z) ! ng CITY STATE zip., CITY ~S E,: ZIP TAT -4~ a 921 3;:); PHONE. FA~~, , PHONE, FA~ '2_5 t . y bdd EMAIL EMAIL 1p "!5 5 t JL8~kj_ I STATE LIC. #: STATE:LIC.#~ SS CITY BUS. LIC.#'~- (Sic. 7031`5 Business and Professions Code': Any City, or County which r6quir6s a p6i~nit to construct; 61ter~ improv6, demolish or repair. any stritict6rd~ prior to its-issuance, also requires the, applicant for such1permit-to:file a signed Statement thatihels licensed pursuant to.the provisions of the Contractor's License Law (C apter,q crimitne th Section 7000~bf Division 3, of the Business and Professions Code) or that he'is exempt therefrom, and-the'basis for,~Itie alleged Fxemption: Ahy violation *of Section T031:5 arl, ,rol= a permit subjects the applicant to a civil penalty of,not.rnore thanfive hundred dollars ($500)). ~4, Workirs",CompentaflonDecieriton'.Iher6byatt)rm~nderp~n~ltvofp6~Oiyon6,'oftheiotio~vihg'd~O~i~gon~., E:1'Ihi4e an wili(mil Work I Wh. A _ ntain acertjWcaieo~fc~'hientio-self-insure'for W'~orke~',~cp,rnpbfisafiofi`as pimidetit(ySido'n 3706'of the ~bck ~6tle,~f6i'6e perftirman; ce of the ssued. on, as re iilill of the Llib& Goode'; for t e performance oil th" or . icl~ this permit is' Ell'~iivi'iind will m iintain workari~ ~om~eAati quired ti~ Ski= It e wo`~ for wh8hth'is permit i's issued. Myy'~orkers' compensation irisuran6e carrier.a h`a' iicy 11 ~ -1 - ;t4 " ~ , , '~ ~, ~ ~ ; , I- t: ~, r, ~s' I ~, ., _ ". ~~- t_, ~J ~ I I ." , , , I - '' I - , po! Ex Y 6iratio~hbate ce 11C n6mber are. InSuran Po y No. is to imple r one hundred dollars ..This section'need not W oo 'ted ifthe 1p_~tmit $ 1 00) or, less. Cirtikate of Exemption:1 certify that id the:pe~rforn~6 I rice of the w,o~k for which 'this peit~it i~ is~66d~.'I'shall not bmploy an~_06rsiin'in any manner so. as'to become subject to the Wiorlkers"Co~piinsaticin' Laws of , C 'T ARN e~ . to, , s . ecure workers' ~omp . en s, ' '&Oriija ii unlawf4 a4shiiill subject ~n einol~yei~ to cdmin'al Oini'iijuis and civil ohis up to driehurdrit thousand doll . a - rs I &I . 00,000 .. ), i I n - alifo ia. W ING:Failur ation c addition f6the coii of con6ensaitio'"r, dimiages'as- 'i f' re4and ati6;4~'s feps`;~. provided for in I ection 3706 o , the Labor code, inte I)AT -.CONTRACTOR SIGNATURE E []AGENT _064 I herebk affi,m thdt I am exe*mpt from C.-itractor, s License Law tor rne following reason. F_71 i"asow~erofthepiope4 I or 'my empoyees with wages as theirs'616 compcii~auuo', Wili'.do the.wokand the strUc;tUre'is not intended 6r offered for Sale (Sec. 7044, Business and Professio"nS CodIi The Con'ta.rors inse Law does ntifa~ply`t~ an owner ofp m0ert, prtniii a y who builds"6~ improves th6r~o~,~and who does such.work hi.insiff orthrb ' u6 ' It his oWn'~m'01606s; Orov~ideti,t6t ' such,im ' rnq~fi ~ re hot fittended or offered for sale. If, fiowever, tKe building or impntivernent'is sold within one ~ear of com~leiion,the owner-buildeT Will have the bu rden of proving that he did not build'6r improie for the puipose of sale). 1, as owner ofthe p~~r~,4rn e~cluiivelj'6ontrabting with licensed'contra6tors to conitruct the project (Sk. 7044~ Business iind,Profesiions CodeJhe Contractoes'License Law does - not apply t6 afi~ow4r of,, Se W). 'Oh5obj who builds oi~ improves therekin~:and cor~tracts f6rsuch pr6jects with contractor(s) licensed pur~uant to the 6htracio'rsLicen LA' Nm ~.xempt'uncler Section 8 siness and Professionscodelfoithis reason: 4 I pe~rsitnally'plan to provide the major 6b6'r and materials-for 'construction o I e propqs~d property improvement. nYes 2. 1 (have / have hot) sig4ed an appli6tion for a building permit for the proposed Work. 1 ' '~'!66ntiiicted ~th I Ili I roposed constfucfion (ii I e - o owing Von (1~inrij o prow a. ep icU6 nam6'address phone /cohtractors'.Iic~;ise number): p 'I I f h' u hired the follilwing ~erson~io o~o~in6ti,`!Opervise and pi6vid;'ihe'i4iajor~'Work (indude'nime )'iItidr6ss phone /c6ntra60'-rS' licensd'numb6i~)~-,- an to.provic I e portio so I a wo.r.k/6 I I'hav~ ed) I 5. 1 will pibMe some of the-work, b have contricted (hi !r ns to';~~vlide ih'~4o~ indic.iedljincl~de nairine kaddr~e"Ss /'phop'e type of work t DATE PROPERTY OWNER SIGNAT VjAGENT, 17f ~55_~Z- Z, i 01- ~A" L Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tinner Hazardous Substance Account Act?. Yes , ',No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 3~-,Yes i", No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? - ' . i _j,Yes fN No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the perfor . mance of the work this permit is issued (Sec. 3097 (i) Civil Code).* Lender's Name Lender's Address ... . . .... . . .... I C~r* tha't 1, have read the application and state that the above information isooffectand thatthe information onthe plans isaccurate. I agreetDoomplywith all Cftyordinanoes and State laws relatingliD buildingconstruction. I hereby authorize representative ofthe CityofCaAsb~ad to enter upon the above mentioned property for inspection-purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINSTALL UABILITIES, JUDGMENTS, COSTSAND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA. An OSHA permit is required for excavations over 617 deepand demolition orconstruction ofstructures over3 stories in height. EXPIRATION: Every permit issuid by the Building Official under the provisions of this Code skall expire by limitation and become null and void 9 the building or work authorized by such permit is not oDmmenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106A.4 Uniform Building Code). A5APPLICANT S SIGNATURE DATE 4 STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. PermitType: BLDG-Residential Application Date: Q9/012/2015 'Owner: ~,TRUST MALENCZ FAMILY TRU.ST 06-26-87 J Work Class: Addition ,ISSU6 Date: 03/2W2016 Subdivision: Closed - R "Statu':` n a I e~'d Ex0iration Date: O~/30 /2017 Address: 2624 Obeliico' PI - C6'rlsbad, CA 92009 IVR Number: 708957~1 Scliedule~ Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection -complete b~te` Start Date. 11/14/2016 11/14/2016 BLDG-84 Rough 000637-2016 Failed MIchiiel Collins Reinspection Complete Combo(14,24,34,44) MMENTS Checklist Item CO _j Passed BLDG-Building Deficiency No BLDG-14 No Frarr~e-Steel-Bolting-Welding.. (De cks BLDG-24 Rough -Topout', No BLDG-U Rough Electrical No BLDG-44 4. 'No Rough-Ducts-Dampers 11126/2016 41/28/20`16 BLDG-27 Shower 00:~266-2016' Passed Michael C611ins Complete Panffu~s Checklist Item COMMENTS Passed BLDG-Building Deficienc y No 4 BLDG-84 Rough, 002929-20 16 Passed Michael 'Collins, Complete . Combo(14,24,34,44) Checklist Item 'COMMENTS Passed BLDG-14 No. Frame-Steel-Bolting-Welding j (Decks) BLDP-24 Rougo-Topout No BLDG-34 Rough Electrical No~ BLDG-44 No Rough-Ducts-Dampers NOTES Created By ,,TEXT Created Date Michael C61liA Complete all tr des. Frame not per plan. 11/14/2016 lo u/01126'6' ~12/01/20_16' BLDG-17 Interior 003773-2016' Passed Michael'Collins ,Complete. Lath/Drywall' - . . I o . -4 1 , 0 NOTES Created By TEXT", Created baie~'__ MichaelCollins' Drywall only. 12/61/2016 12/02/2016 1 12/02/2016 BLDG-17 Intehor 004013-2016 Passed Jonaitha~West c6mpiete Lath/DrMall Checklist Item COMMENTS A. Passed 'BLIDG-Building Deficiency Yes' BLDG-23 6041'35-2016 Passed Jonathan West Complete t Gas/Test/Repairs February 17, 20117 Page I of 2. L P11mitType: 'BLIDG-Residential Application Date: '.09/02/2015 TRUST MALEWCZ FAMILY TRUST 06-261-87 W64 Cla'ss' Addition' Issue Date: 03/23/2016 Sbbdivision:, 'Status: Closed - Finaled Expiration Date: 05/30/2017 Address: 2624 Obelisco PI 'Carlsbad, CA 92009 IVR Number Schedule'd 4, Actual ~nspection Type Inspection No. Inspection Status Primary Inspector Rein4ection Complete Date Start D~ate 4 Chkklisk Item 60MIMENTS Deficiency Yes 01/13120`17' 01/13/2017 BLDG-Final 009679-2017, Failed Andy Krogh Reinspection % Complete inspection Checklist Itim C6MMENTS Passed PLDG -Plumbing Final Hose Bibb'vacuur~ breaker'at upstairs hose No, 4 Bibb BLOG-Me~hanical Final y6s BLDG-Structural Final, ~es.t- BLDG-Electrical Final, GFC '~t new tv plugoutsidej No 14 02/17/2017 02/17/2017 BLDG-Final 014052-2017 Passed An dy Krogh Complete Inspection Checklist Item- - COMMENTS Pass6d 'BL G-Plumbing Final-D Yes BLDG-Mechanical Final Yes BLIDG-Structural Final Yes ect BLDG-E1` rical Fi6al, Yes lo, 4 4 ,February 17, 2017: Page 2 of 2 Inspection List Permit#: CB152882 Type: MALEWICZ: 171 SF IST &-2ND FLR RESDNTL RAD 135 SF REMODEL ENLARGING KITCHEN, Date Insp6ction Item Inspector Act Comments 10/26/2016 13, Sh6ar Panels/HD'~. Py AP 10/26/2016 15 Roof/Reroof PY AP 10/14/2016 11 Ftd/Foundatio6/Piers Mc AP PATIO FOOTING/COLUMNS 10/13/2Oi6 11 'Ftg/FoUndation/Piers MC CO NOT PERPLAN. 09/21/.2016 11 Ftg/Foundeition/Piers MC AP KITCHEN STEM WALLS ONLY. Tuesday, F6bruary 21, 2017'. .Page I of 1 FIELD. REPORT.,- TO 7 DATE -FPROJECT A17 8 6 //(! g NO. 1 -7 C~ <) 9 PROJE,bT LOCATION CONTRAdTOR OWNER A~- le- WEATHER CONDITIONS PRESENT AT SITE EQUIPMENT SUMMARY OF INSPECTION: Okt -/— o ~,4Vc, -wVc- <- /6w 101,io A 0, Oxen-a cX-e-s-, Vic 1100 C"/7c <LA".n a/c t~~'40 . "n, p (t-r<--cq Ac- I/ Aw"IN C-elc 7-0~~ f 1,4z Q e, JC C34 zg7 7'2A4,- /I V j RECOMMENDATIONS: 2 1—~V%o'7 - 11 I GUr L,4 1*1001 C, 41ool HETHERINGTON ENGINEERING, INC. SOIL &.FOUNDATION ENGINEERING ENGINEERING GEOLOGY - HYDROGEOLOGY 5365 Avenida Encinas, Suite A Carlsbad, California 9200 - 8 (760) 931-1917 www.hetheringtonengineering.com SIGNATURE 327 Third Street Laguna Beach, California,92651 COPIES TO: (949) 715-5440 rA I FIELD -REPORT, TO At A offl A toxe- 7- - SUMMARY OF INSPECTION: DATE 140 46 PROJEC T NO.' PROJ9 T T z 6 z f ~ Me xcr 5 ev PI&I.Ae-E LOCATION. CARL.c.4AN CONTRACTOR OWNER WEATHER CONDITIONS PRESENT AT SITE EQUIPMENT 7"o- &~"EJWA57 AA/b I'Arf. T- Aeg- 7 A Aj o jq A a 7--r op A_t'. t1*"XXr4ArJCkY /Z .7,--V- CA JFS FLACXI~! Am)> Cj&2"A4-rC-h -,050A bkOt-0-SEA ?AT_r_zP OFF OF APPA'rlf EAST. Colemsk. OF F;er7 A-TXAJ6- S I-oz U e_-ru k r-- rWO b-9-Alp-rre nxisz-s r_-A m, r k) ty/ A3y4Lx,Ar_. b97 ALS_Xr~?- 6VA1yLC--'AJV> A ACAPAELE 40F 4rr,44, COit.'E e- rF F_k~ R L A 13 p X A T-49 rwi!a rrw & LEA-47- ka,=,4 r_zpr_ rza ng f RIECOMMENDAT1ONS: SIGNATURE COPIESTO: HETHERINGTON ENGINEERING, INC. SOIL & FOUNDATION ENGINEERING ENGINEERING GEOLOGY * HYDROGEOLOGY 5365 Avenida Encinas, Suite A Carlsbad, California 92008 (/60) 931-1917 www.hetheringtonehgineering.com 327 Third Street Laguna Beach, California 92651 (949) 715-5440 'Corporation E.§Gil 'In Tartnership- with Gov'ernmentfo~.(Buifdin~ Saf~ty DATE: 3/17116 El APPLICANT El JURIS. JURISDICTION: Carlsbad 0 PLAN REVIEWER 0 FILE PLAN CHECK No.: 15-2882 SET: III PROJECT ADDRESS: 2,624 Obelisco Place PROJECT NAME: Milewicz SFD Addition, Remodel and Patio Cover F-1 The plans transmitte*d herewith havd. been corrected wherre necessary and substantially comply with the jurisdiction's codes.. E I 'The plans trainsmitted herewith will substantially_ comply with the jurisdiction's building codes when minor deficiencies, identified below are resolved and, checked by building department staff. -Z The plans transmitted herewith have not. been approved. Z REMARKS: The plans, ha'v'e not' been ap"peove&'and are bel - ng returned to thetity per the request by Janet Altar in an email dated 3/17/16,. Thank you. By: Tamara Fischer Enclosures: EsGil Corporation [:1 PA F1 EJ El MB E] PC 2/25/16 9320 Chesapeake Drive, Suite 208, San Diego, California 921,23 (859) ~60-1468 Fa~x (858) ~60-157~,-- EsGil Gorporation In TartnIership with GoTernmentfor (Buiffing Safety DATE: 3/3/16 LI LICANT I~AJ U R ILS. JURISDICTION: Carlsbad U. PLAN REVIEWER 0 FILE PLAN CHECK NO.: 15-2882 SET: III PROJECT ADDRESS: 2624 Obe.lisco Place P p J ECT NAM E:.Malewicz SFD, Addition, Remodel and Patio Cover /OJ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. /V T hie plans transmitted herewith will substantially comply with the jurisdiction's bbildingcodes when minor deficiencies identified below are~ resolved and checked.by building department staff. 0 The plans transmitted herewith have significant deficiencies i ' deritified 'n the enclosed check list and should be corrected and resubmitted for a complete recheck. The'check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck.. F-1 The applicant's copy of the check list is, enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Travis Deal F -1 EsGil Corporation staff did not advise,the applicant that the plan check has been completed. E'sGil Corporation staff did advise'the applicant that the plan check has been completed. Persoa contacted: Travis Deal Telephone #: q-6"9-3 9 Email': travisdeal@yahoo.com Date contacted: ~Q-Mail Tele-~hone Fa.x In Person, F-1 REMARKS: By:' Tamara Fischer 'Enclosures-~ EsGil Corporation El GA EJ Ej MB n PC 2/25/16 9320 Chesapeake Drive, Suite 208 San Diego, California 92123 (858) 560-1468 Fax (858) 560-1576 Carlsbad 15-2882 3/3/16 NOTE: The items listed beloware frorn the previous correction list. These remaining items.have not bben adequately addressedi The numbers of the item's ate from the previous ched1k list and may not neceisarily be in' seq uence.' The notes in underlined, bold font are current. Please make all corrections, as requested, in the correction list: Submit FOUR new complete sets 'of plans for commercial/industrial projects (THREE sets of plans for. residential projects). For expediti6us processing, corrected sets can be submitted in one oftwo ways: 1-.-, Deliver all corrected sets of plans and caldulations/reports directly to the"City of Carlsbad Building- Department, 1635 Faraday Ave',, Carlsbad, CA 92008,,(760) 602-2700. The.City will route the plans to EsGil Corporation,.and the Carlsbad Planning, Engineering and Fire Departments. -2. Bring one corrected set of plans arid calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite'208, San Diego, CA, 92123, (858) 560-:1468': - D I i , n I V e el ver all remain'. g sets of plahs and calcdlations/r* ports,dir6ctly to the City of Carlsbad ~ Building Department for'r outing to their Planning, Engineering- and -Fire Debartm6nts. NOTE: Plans that are submitted directl~ to EsGil Corporation only will not be' reviewed by the City Plann.ing, Engineering and Fire Departments until review by EsGil Corporation is complete. PLANS' All,sheets of plans must be sig~ed by~the person responsible fo( their -are prep~irzition. (California Business and Professions'Code). Current plant signed. This will be re-Verified on final iets. Designer's signature is needed ori the CF-1 R. Plans deviatirig from 'conventional Wood frame construction sfiall have the structural portions signed and sealed,b ythe California state licensed engineer or archiiect r6spo'nsiblefor their preparation., along with structural calculations. (California Business and Professions Code). Current structural portions are sealed and signed. This will be re-Verified on final sets. Sheet 6 needs the seal and signature of the engineer. FOUNDATION REQUIREMENTS -'~Pro'vide a letter from the s , "oils engineer c , onfirming .-that'the foundation plan, grading plan and specifications have been'~eviewed and that it has been d r etermined that the recommendations, in the soils, report are properly incorporated into the construction documents (if required by the soil report). Response indicated that the letter was attached., I was unable to locate this-, review letter. The response indicated letter was attached, but the letter was not received. CONTINUED C.Arlsbad"15-2882 FRAMING /STRUCTURAL, 'Please chec,kl detail 8/4A. Should the:Ieft side of it be the patio cover frarnihg?. It still seems the detail is inaccurate. The, detail-is referenced looking, south and the new LSL -is shown on the right side, so it seems the left side hould be patio cover joists running parallel. Regarding s detail 8/4A: Please see section B/5 and framinq s w e plan which ho th ' floor above the beam, the 2nd story wall above the beam (not off-set as, shown in the detail) and the patio cover supported by a ledger. MISCELLANEOUS To, speed up the review, process, note on this list (or a copy) where each correction item has been, addressed, i.e., plan sheet, note or detail number, calculation page,.- etc. Please indicate here if any changes have been made fol the plans that are not a result of corrections from this list. If there are other changes, please briefly, describe them and where. they are located in the, plains. Have changes been made to the plans not resulting fr'm'thi*s correction, list? Please indicate: Yes L31 'No Ll The jurisdiction has contracted with Es,gil Corporation I; ocated at 9320 Chesapeake Drive, Spite 208, San Diego, California 92123; telephone number of 858/560r1468, to perform the plan reviewfor~ your project. If you have any questions regarding these, plan review items, please contact Tamara Fischer atEsGih Corporation. Thank you. tEsGil Corporation In Ta~tnership with Goventme'htfor Buitding Safety DATE"' 1/26[16 qAPPLICANT --Q JURI'S. 'JURISDICTION: Carlsbad 0 PLAN REVIEWER El FILE PLAN-CHECK NO.: 15-2882 SET: II PROJECT ADDRESS: 2624 Obelisco Place PROJECT NAME:.Malewicz SFD Addition, Remodel and Patio Cover —1 " F The plans transmitted herewith have been.corrected where necessary a*nd substantially compl withthe jurisdiction's codes'. The.plans transmitted herewith will substantially comply with'the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. F—l' 'The planstransmitted herewith have signifi ca nt deficiencies-id entified on the en I closed check, list and'shou'ld be corrected and resubmitted for a complete recheck' The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until'corrected plans are submitted for recheck.'.., 'F_1 The applicant's copy of the check list is encl.osed for the jurisdiction to forward to the applica I nt contact person. The applicant's copy of the check list has been sent to: Travis Deal F] EsGil Corporation staff,did not advise the a t pplican that the plan check has been completed., "EsGil Corporation staff did advise I the applicant that the plan check has been completed. ''Person contacted: Travis Deal Telephone4: 760 893-9055 (by Email: travisdealgyphoo.com Date contactedA _;:~Mail Tele'phone' Fax, In Person F-1 -REMARKS:- By: Tamara Fischer Enclosures. EsGil Corporation EJ E] MB F~ PC E -GA 1/19/16. 9320 Chesapeake Drive, Suite 208 San Diego, California 92123 (858) 560-1468 Fax (858) 560-1576 Carlsbad 15-2882 1/26/16 NOTE: The it6ms.listed below are from theprevious correction list. These. remaining items have not been'adequately'address6d. The numbers of the'itern's from the. previous check list and may not necessirily be in sequence. The , notes in bold font are current. Please make all corrections,'as, requested -in the correction list. Submit FOUR,new:' complete sets of plans for c6mmercial/industrial pr Jects (THREE sets. of plans for'., oJ residential projects). For expeditious processing, corrected sets-can be submitted'-' in one of two ways: Deliver all corrected sets of plans and'6alculations/reports directly to,the' City of - Carlsbad Building Depart ment, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the Rlans,to EsGil C,orporation and the Carlsbad Planning', Engineering and Fire Departments.-' Bring one corrected set of plans and calculations/r6ports toEsGil Corporation, 9320 Chesapeake Drive, Suite' 208, San Diego CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the Citj of Carlsbad,Buildirig Department for. routing to.their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted dire6tly'to EsGil Corporation only will. not be reviewed-by.the C,ity Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. PLAN S 1 . All sheets of plans must'be signed by the person responsible for their preparation. (California Business and Professions Code). Current plans are signed. This will be rd-verified,bn final sets. 2. Plans- deviatingfrom conventional wood frame 6onstruction shall have,the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, along with structural calculations. (California Business and Professions Code). Current structu - ral portions are sealed and signed. This-will be re-verified on final-sets. 4. Please clarify whether the~area identified as "Existing Kitc hen" is changing at all. If so, show all changes. It'appears that there are only changes to the, existing nook area. Please specify "no changes" at existing part of kitchen. (Or if there are changes, show them)'. 7. Please provide a demo pl6n'or clearly show on the floor plan all w6lls being removed (for example, p. 4 of structural calcs indicates a "wall below to be removed" between grids B and C and 2 and 3). Additionally identify any walls being removed- as to whether they are bearing or shear walls. Was opening where door I to bathroom is located anexistingopening? Please clarify on the plans. CONTINUED Carlsbad 15-2882 1/26/16, FIRE PROTECTION. When alterations, repairs or additions are proposed for dwelling units within which fuel-burning, appliances are installed (and in dwelling units having attached garages), the dwelling unit shall be provided with carbon monoxide alarms :located as required for new.dwellings; the carbon monoxide alarms shall be interconnected and hard Wired. Exception: Carbon monoxide alarms in existing, areas need not be interconnected and hard wired,where the alterations or repairs do'not result in the removal of interior wall or ceiling -finishes exposing the structure, unless there isan attic, crawl space,'or basement available which could provide access for-hard wiring and interconnection without the removal of 9 interior finishes. Section R315.2. Please show in the following areas: a) Outside each separate sleeping area in the immediate vicinity of the bed rooms. Please provide a carbon monoxide alarm outside the master bedroom in the immediate, vicinity. The one shown is too far from the master bedroom. The carbon monoxide alarm is shown inside the master bedroom. One is required. outside the master. in the immediate Vicinity. FOUNDATION REQUIREMENTS The City of Carlsbad requires a soil report for this project. Provide a copy of the project soil report. The report shall include foundation design recommendations based on the engineer's findings and shall comply with Section . R401A., The City bf.Carlsbad requires a soil report for all,2'story projects. .~Please' note that the only exception to the soil report requirement is If a room addition is less than 500 sq. ft. in area and only one story, and a maximum allowable soil bearing value ,used in any design must be 1000 psf forthis exception. This project does not meet the. exception). Please review the soil report and incorporate all recommendations into the design. For example: Footings require (2) #4 top and bottom and slab thickness, reinforcing and underlayment shown on the'. plans does not comply with the soil report recommendations.. 15. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been review ed and that it has been determined that the recommendations in the soils report are properly' incorporated into the construction documents (if required bythe soil report). Response indicated that the letter was attached. I was unable -to locate this review letter. 1& Please specify the size of the'-existing footing at grid 3 on the plans. 2/4A does not specify the size of the existing footing.. CONTINUED a 13 Carlsbad 15-2882 1/261/16 FRAMING /STRUCTURAL' '25. The roof live load reduction must be determined by equation 16-~6 (sectionl6- 7.12.21, CBC). For a member supporting less than 200 sq'ft tributary area and a 6 1/2 :12 pitched roof, the live load reduction comes out to .875. .875 x 20 psf = 17.5 psf. Please revise calcs accordingly. One response referenced revised caics. Only a few sheets of icalIcs (sheets 1,6,9,10,and 12) were received with this submittal and I don't see where this has been revised. Another response stated the whole roof, is greater than 200 sq ft. The reduction is based on the tributary roof area supported by the member. 26. Please show that the existing 4"x`14" header over sliding door C which supports the ridge beam above is adequate for the added loads. Please j ustify the point load used in the calc from the ridge above. It seems' low.., Page 3 of calcs was referenced, but*this co'uld'not be found on, page 3. Also, if this a no.1 grade beam, specify it on the plans. 30. Please provide lateral calculations for this project. I see some shear walls shown, but no hold. downs. No lateral calculations were received. I see no lateral resistance shown at grids 3 and 4 lower level. Additionally, knee braces are shown only in the direction parallel to the house at patio cover. Please address lateral resistance of the patio cover in the direction perpendicular to the house. Be sure a shear transfer detail is provided and referenced for each'condition. Response referenced added sheets from the engineer. There were no lateral clacs'in the added sheets. Please provide them. I see strapping is shown in the perpendicu . lar direction at patio cover but it doesn't appear to be shown at the north end. Many shear transfer details arernissing. Please check detail 8/4A. Should the left side of it be.the patio cover framing? It still se6ms.the detail is inaccurate., The detail is referenced looking south and the newLSL is shown on'th6 right side,' so it seems the left side should be patio cover joists running parallel. Please clarify detail 10/4A and reference it to the plan. I assume it should be referenced at grid 3 upper, but the plan states the inside wall is a non bearing., wall while the detail seems to show it supports, ceiling joists (which are not called out on the framing plan). Show the location of the shear paryel on the detail and how the shear will be transferred from the roof diaphragms to the shear wall. The right wall is still shown as a 2x4 Wall supporting ceiling joists. The shear panel is shown on the right wall where there is a pocket door and complete shear transfer is not shown-Please have the engineer review and revise the detail accordingly. CONTINUED Carlsbad 15-2882 1/26/16 .34. Please detail retrofit anchor bolts for shear wal.1s. 'No response received. 35. If epoxy anchors are needed for retrofit.hold downs,,,please detail them, specify special inspection required and'complete the attach ed City.fqrm. Response stated not required per, structural engineer, but no substantiating calcs were received. A. It *was noticed that blocking is not shown below' the bearing wall supported by the floor joists. MECHANICAL ELECTRICAL,/ PLUMBING 37. Specify'on the plans the following information for the gas fireplace. (Must be a direct-vent model per California Gree'n-Code): , a) Manufacturer's name/model number and ICC approval number, or equal. The fi , replace specified is an Isokbrn modular masonry fireplace Which is wood burning or gas.with a 13.vent. A B vent fireplace is no longer allowed in California. Additionally this fireplace has requirements for structural -design and detailing as outlined in the ICC approval. Please specify a direct vent fireplace. and provide the information requested above for it. RESIDENTIAL GREEN BUILDI ' NG STANDARDS The California Building Standards Commission has adopted'the Green Building Standards Code which became effective: January 1, 2011 and must be enforced by the'local building official. The following Mandatory requirements for residential construction must be included on your,plans. 'CGC Section 101.3. The Standards apoly to newly constructed residential buildings', ildh`g', -with' 'incr,`eas&,`the~ ui ing,.-§,~-- -d-t" `d-' volume or t 'at, _r ~ `6 1& ~- nm ione area 'add-"- t ;ons p size. CGC Section 303. 1. 1. Please~add the following to Green-Building Code notes on sheet 3. 41. Note on the plans that the gas fireplace(s) shall. be a direcf-vent, sealed- combustion type. Woodstove or pellet stove s must be US EPA Phase 11 rated appliances. CGC 4.503. 1., Fireplace specified is not. direct vent.. CONTINUED Carlsbad 15-2882 1/26/16 ENERGY -CONSERVATION 43. Pro v*ide a Prescriptive or Performance energy design, demonstrating compliance - with current 2013 energy efficiency standards..., Information and. Forms are available at: www. energy. ca. gov/title24/201 3sta hd 0 rds. As shown the project cannot comply with the prescriptive requirements based on.th'e amount of glazing being added. ~, (For Additions < 400 sq. /ft-.; Maximum total allowed glazing is up to 75~sq. /ft. or 30% of conditioned floor, area. (whichever. is greater) and'up to 60 sq./ft, of west-facing glazing).. Please,note that removed glazing can no longer be deducted fromPe total. a) energy calcs use, RI 9 for walls and R30 for roof.- This would' require 2x6 studs and 2x10 roof joists. (Unless ceiling joists are to be used and there is room for the R30. Please note that attic must be vented in'that case). MISCELLANEOUS To speed upthe review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number,. calculation. page, etc. Please indicate here if any changes have been made tothe plans that, are not a result of corrections from this list. If there are other changes, please briefly describe them and a where they are located in the.plans. Have changes -been, made to the plans not resulting from this correction list? Please indicate: Yes- Ll No Ell The jurisdiction has contracted with Esgil Corporation, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; -telephone, number of 858/560-1468, to perform the plan review for your,project. If you have any questions regarding these plan review items, please contact Tamara Fisc.h6r.at EsGil Corporation. Thank you. EsGi.1 Corpor.atiom In (Partnership with Governmentfor Buiffing Safety DATE: 9/15/15 O.APPLICANT JURIS. JURISDICTION: Carlsbad U PLAN REVIEWER Q FILE PLAN CHECK NO.:'J5728,82.- SET: 1. PROJECT ADDRESS: 2624 Obelisco Place PROJECT NAME: Malewicz SFD Additioin,'Rerriodel and Patio Cover F71 The plans transmitted herewith have been corrected where necessary, and substantially comply, with the jurisdidtion's codes. F-1 The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. F The plans transmitted herewith have significant deficiencies identified on the enclosed check list ,and.should be corrected and resubmitted for a complete recheck. The check I ist transmitted herewith is for your information. The plans are'being held at Es'il P 9 Corporation until"corrected plans are submitted for recheck. _The applicant's copy,of thecheck list is enclosed for the jurisdictionto forward to the applicant contact person. The applicant's cop of the che c k list has bee n sent to: y Travis Deal Corporation staff did not advise the applicant that the, plan check'has been. completed. F-1 E~sGll EsGil corporation staff did advise the~ app.lic'ant. t.hat the.plan,.,check has been completed. Personbontacted: Travis Deal Telephone #: 760 893-9055, (by:Y)4j—, Email: t'ravisdeal@yahoo.COM ~Dat - e con~acted: /7&pil, %~4elephone Fax In Person ''REMARKS: By: TAmara- Fischer Enclosures: EsGil-Qorporaltion, E] GA EJ E~:] mbl-' F~ PC 9/8/15 9320 Chesapeake -Drive, Suite 208 -San Diego, Califomia 92123 (858) 560-1468 Fax'(858) 560-1576 C~arilsbad 15-2882 4j15/15' PLAN RE VIEW CORRE CTION LIST -.SINGLE FAMILY DWELLINGS AND DUPLEXES ~LAN,CHECK NO.: 15-2882 JURISDICTION: Carlsbad .PROJECT ADDRESS: 2~624 Obelisco Place FLOOR,AREA: '17 1'sq ft SFD Add STORIES: 21 .' 256 sq ft Patio Cover J3.5 sq ft Int REm odel HEIGHT: (Existi'ng) N/C REMARKS: bAT ' E PLANS RECEIVED.,BY, DATE PLANS RE'6EIVED BY JURISDICTION: ESGILCO . RPORATION: 9/8/15 6AT't INITIAL PLAN REVIEW PLAN REVIEWER' Tamara Fischer, COMPLETED: 9/15/15_, FOREWORD (PLEASE READ):.. This plan review is. limited to, the technical requirements cont6ined in the California version of,:- the International Residential Code, International Building Pode, Uniform Plumbing Code, Uniform Mech~ni6al Code', National Ele6t.rical Code. and state law's regulating energy conservation, noise attenuation and*access for the disabled. This- plan review. is based. on regulations enforced by the Building, Department..Y6u m ay''have, other'corrections based o n' i6ws and ordinance by the.Plannin4 Department, Ehgineering': Department, Fire Department or ~ther, departmeints. - Clearance from those departments may be required prior to the issuance of a ,building perrnit.- -const' 0 Present'California law mandat6s that. ruction c'mply with the 2013 edition of the California Code of Regulations.(Title'24'), which; adopts the following model codes: 2012- IRC, 2012 IBC - 2 -UPC, 2012 UMC and 2011 NEC. 012, The above regulations apply, regardless of the &ode'e'ditions adopted by ordinance.. Thefollowing items listed need clarification, modification or change., All,items must be satisfied be in conformance with the cited Codes and regulations: PerSec.,105.4of 'before the plans will the 2012 International'Building Code the a proval of 'the plans does not permit the violation . -of - p an~ state,, county pr city law.'.- o speed up the recheck 'Process, - please.note -on'this list jor a ~opO where e~ch correction item has beeh addressed, i.e., plan~sheet nurriber,' specification se6tion, etc. .,Be. sure.to enclose the marked up fist when you sdibmit the revised plans. Carlsbad 15-2882 9/15/15 Please make,all corrections., as requested. in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for 'residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1 ,Deliver all corrected sets of plans and calculation.s/reports directly to the City of, Carlsbad- Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will r6ute the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Z, Bring one corrected set of plans and cald ulations/r6ports to, EsGil Corporation,, 9320, Chesapeake Drive, Suite ~08, San Diego, CA 92123, (858) 560-1468. Deliver all' remaining: sets of plans and calculations/reports directly to the City of Carlsbad Building. Department for routing,to their Planning, Engineering and Fire-Departments. NOTE: , Plans that are submitted directly to EsGil Cor e e poration only will not be revi w d by the City Planning, Engineering and, Fire Departments until review by Es.Gil Corporation is complete., PLANS 1.- All sheets of,plans must be signed by the. person responsible for their- preparat,ion. (California'Business and Professions CO de). Current plans. are signed. This will be re-verified on final sets. 1 2. 'Plans deviating from conventional. wood frame construction shall h.ave the structural portions signed and sealed by the California state licensed engineer or architect responsible for their preparation, alorigwith, structural calculations (California Business and Professions Code). Current structural portions are sealed and signed. Thiswill be re-verified on final sets. Specify on the T itle Sheet of the plans the gros's floor'area of the patio cover and remodelarea. sectio'n-R106.2. Please clarify whether the area identified as "Existing Kitchen"'is cha.riging at, all: If so, show all changes. Please dimension the distance from the dashed setback lines to the property lines or dimension.th I e distances from the addition- and,patio cover to the property".~ lines,on the site plan.1 Plea se identify the existing portion of the house as "e I kisting" on the site plan. Please providea derno'plan or clearly show on the floor plan all walls being' removed (for example,. p. 4 of structural balcs indicates a "wa.11 below.tobe removed" between grids B and'C and 2 and 3). Additionally identify any walls being removed asto whether they are bearing or shear walls. CONTINUED Carlsbad, 15-2882 9/15/.15 FIRE PROTECTION .8. Please,'indicate on,the plans whether the existing residence has a fire, sprinkler system installed. If so, then provide a note. stating that any additidns/alterations, will.bo provided with an automatic residential fire sprinkler systern. Section R313.2.' 9.' When alterations, repairs oraddition's are, proposedfordwelling units' within- which fuel-burnin' appliances are installed (and in dwelling units having attached garages), the dwelling unit shall be provided with carbon'monoxide alarm's located as requirpd.flornew dwellings; the ;carbon monoxide alarms shall be inte'rconnected'and'hard wired. Exception: Carbon mo I n,oxide alarms'in existing areas need. not be int.erconnecteld,and.hard wired wHere-th.e, alterations or repairs do Pot result in.the removal,of interior wall-or ceiling finishes exposing the structure, unless there is an attic, crawl'§pace, or basement available 'which could provide access for hard wiring:and interconne'ctioh without the removal of interior finithes: Section R315.2. Please,s,How.in the,following areas'. a) Outside each. separate sleeping, area in'the immediate vicinity of the bedrooms.,,Please provide a*carbon monoxide alarm outside the master bedroom in, the immediati vicinity., The one shown is too'far from the.master bedroom. b), -On each story, including basements. Please'prdvide a carbon monoxide on the first floor.' GENERAL RESIDEN-MAL, REQUIREMENTS .10. It appears there is an'existin' door to the deck from;the bedroom adjacent to the 9 :,new'bathroom.,- Please call it out on the plans (for emergency egress, Nerification). Section R310. Please correct larger'new..bath room' -window, reference at,sheet 3. It appears it should be window E, not C. ROOFING Pleasespecify the roof application using the prod, ucts called, out in the ICC report for the'Class A roof assembly to be used. - CONTINUED Carlsbad 15-2882 9/15/15 FOUNDATION REQUIREMENTS The City of Carlsbad requires, a §oil'report for this project. Provide a copy of the project soil report. The report shall include'foundation design recommendations based on the engineer's findings and shall comply with Section R401.4. The. City of Carlsbad requires a soil.report for all 2story projects. (Please note that the' only exception to the soil report, requirement is If a room addition is less than 500 sq. ft. in area and only one story, and a maximum allowable soil bearing value used in any design must be 1000 psf for this exception. This project does not meet the exception). If the: soils engineer recommended that he/she review the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, -the soils engineer shall advise the building official in writing that: The building pad was prepared.in accordance with the soils report, The utility trenches have been properly backfilled and compacted, and c)' The foundation excavations, the soils expansive characteristics and bearing capacity conform to the soils report. 15.1 Provide a letter from the soils engineer confirming that the. foundation plan, grading,-plan and specifications have been reviewed and that it has been determined that.the recommendations in the'soils report are properly incorporated into the construction documents (if required by the soil report). 16 . Fd'undation anchorage in Seismic Design Categories C, DO, D1' and D2- In addition to the requirements of Section R403.1.6, the following requirements shall apply to wood light-frame structures in Seismic Design Categories Do, D, and D2 and wood light-frame townhouses in Seismic Design Category C. R403.1.6.1: Plate washers conforming to Section R602,11.1, 0.229"x3"x3", shall be provided for all anchorbolts over the full length of required braced wall lines. Properly sized cut washer shall be permitted. for anchor bolts in wall lines not containing'braced wall panels. 17' Note on plans that surface waterlwill drain away from building and show drainage 'pattern. The grade shall fall at 2% per City, Policy. (Detail 3/4A shows 1 %) Y Section R401.3. Please specify thesize of the existing footing at grid 3 on the plans,., Please specify 26 gauge sheet metaLto separate the existing wood. from new concrete at detail 2/4A. 20.. If patio is level with kitchen floor, how will the weep screed be minimum 2"'above the patio at the adjacent wall? Please provide a detail. R703.6.2.1-. CONTINUED Carlsbad 15-2882 9/.15/15 Please clarify the area between grids 2 and 3 and C and D. Is this an existing Slab floor,? Please clarify what is new and what is existing and provide complete foundation detailing for this, area, including between the new andexisting floor slab in- this area. (See section B/5 which shows the slab in this area) FRAMING /STRUCTURAL, Please provide material specifications on th&plans. The information I have shows that 5 1/4" is not an available width for Timberstrand LSL and Fb =,2325 psi for this product, grade 1.55 E. (Beam 131). Specify nail size and spacing for the roof diaphragm. Specify plywood grade and panel span rating for roof diaphragm.. 25.. The roof live load reduction must be determined by equation 16-26 (sectionl6-, 7.12~2.1 CBC). For a member suppprting-less.than 200 sq ft trib,Utary area, and -1 2 pitched roof, the live load reduction comes out to..875. .875 x 20 .a 61/2. psf 17.5 psf. Please revise calcs.acicordlingly. rts Please' show that the existing 4"x`14" header*over sliding door C which supp6 the ridge beam above is, adequate for the. added loads. Please detail attachment of patio cover.t6 existing house.",. Detail 6/4A calls out P 6x6 post beyond, butl do not see any 6x6 posts called out at"thia location on the plans. 2 9'., S1 is not listed on the shear schedule~. 'Please provide lateral calculations for this project. I see'some~ shear walls shown, but no hold downs.- No lateral calculations were received: I see no lateral resistance shown, at grids 3 and,4 lower level. Additionally, knee braces are shown only. in the direction parallel to the,hbuse at patio,.cover. Please address. lateral resistance ofthe patio cover in the, direction perpendicular to the house. Be sure-a shear transfer detail is provided and, teferOnced: for, each condition. The wind calculations must be,,based'.oh the 201.3 CBC /ASCE 7-10' and Per Figure 1609A,. the win'd load'c~lculations must use an ultimate Wind~ speed of 110 mph. Please check detail 8/4A Should the left side -of it be the,patio cover framing? , CONTINOED Carlsbad 15-2882 9/15/15 Please clarify detail 10/4A and reference it to the plan. I assume it should be referenced at grid 3 upper, but the plan states the inside wall is a non bearing wall while the detail seems to show it supports ceiling joists (which are not called out on the framing plan). Show the location of the shear panel on the detail and how the shear will be transferred from the roof diaphragms to the shear wall. Please detail retrofit anchor bolts for shear walls. If epoxy anchors are needed for retrofit hold downs, please detail them, specify special inspection required and complete the attached City form. 0 MECHANICAL / ELECTRICAL / PLUMBING If the existing HVAC and water heating systems are to be used for the addition, please specify this on the plans, otherwise provide complete information for new systems and further corrections may apply. Specify on the plans the following information for the gas fireplace. (Must be a direct-vent model per California Green Code): a) Man ufactu rer's'name/model number and ICC approval number,'or equal. All receptacle outlets in'the kitchen must be GFCI protected. NEC 210.8 39., . Show the shower stall'can accomrTiodate a 30" circle and has a minimum floor area of 1,024 sq. in. CPC Section 408.6. 0 RESIDENTIAL GREEN BUILDING STANDARDS The California Building Standards Commission has adopted the Green Building Standards Code which became effective January 1, 2011 and must be enforced by the local buildi - ng official. The following mandatory requirements for residential construction must be included on your plans. CGC Section 101.3. The Standards apply to newly constructed residential buildings,,., , al,bn"'- "WitR idditid"n"sialtLir'aitio'hs'.t 'a-tJhcrea" 'e'th ''d volume or s Lihg~~--,.qqh i (Oj size. CGC Section 303.1.1. Please add the following to Green Building Code notes on sheet 3. 40. Storm water driainage/retention during construction. Note on the plans: Projects which disturb less than one acre of soil shall manage storm water drainage during construction by one of the following: A. Retention basins. B. Where storm water is conveyed to a public drainage system, water shall be filtered by use of a barrier system, waffle or other approved method. CGC 4.106.2. CONTINUED Carlsbad 15-2882 9/15/15 4-1. Note on the plans that the gas fireplace(s) shall be'a directrvent sealed-* combustion type. Woodstove or pellet stoves must be US EPA Phase 11'rated appliances. CGC 4.503.1. Interior moisture control. Note on the plans that concrete slabs will be provided with a capillary break. CGC 4.505.2. 1. ENERGY CONSERVATION Provide a Prescriptive or Performance energy design, demonstrating compliance with current 2013 energy efficiency standards, Information and Forms are available at: www.energy.ca.gov/title24/2013standards. As shown the project cannot-comply with the prescriptive requirements based on the amount of glazing being added. (For Additions < 400 sq. /ft.?- Maximum total allowed glazing is up to 75 sq. /ft. or 30%.of conditioned floor area (whichever is greater) and up-to 60 sq./ft. of west-facing glazing).'Please, note t ' hat removed glazing can no longer be deducted from the total. Current Performance energy design versions are: CBECC-Res V4, V3, V3b1 and V3c (Public Domain software)- (New permits-after 07/31/2015 must be W) http://www.bwilcox.com/BEES/BEES'.html EnergyPro (After 07/31/20.15 must be V6.6) www.enerqvsoft.c.om Rig ht-Energy Title 24 V1.4, V1. 3; V1. 2, V1. 1 (After 07/3112015 must be V1.4) www.wri.ghtsoft.com Include all applicable sectio.ns of the MF-1.R form with the plans. 0 MISCELLANEOUS 0 To speed up the review process, note on this list (or a copy) where eachcorrection item has been addressed, i.e., pl an sheet, note or detail number, calculation page, etc. 0 Please indicate here if any changes have been made to the plans, that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. e Have changes been made to the plans not resulting from this correction list? Please indicate: 0 Yes E3 No El The jurisdiction has contracted with Esgil Corporation located at , 9320 Chesapeake Drive,, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Tamara Fischer at EsGil Corporation. Thank you'.. Carlsbad 15-2882, 9/15/15 [DO NOT PA Y— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 15-2882 PREPARED BY7 Tamara Fischer DATE:- 9/,15/15 BUILDING ADDRESS: 2624 Obell'sco Place BUILDING OCCUPANCY! R3 BUILDING AREA Valuation Reg. VALUE PORTION- (Sq. Multiplier' SFD ADD 171 166.81 28,525 Patio Cov 256 12.13 3,105 Int Remodel 135 68.98 9,312 Air Conditioning Fire Sprinklers TOTAL VALUE 40,94~ jurisdiction Code By Ordinance 'Bldg. Permit Fee by Ordinance $348.89 I Plan Check Fee by Ordinance $ 226.781 Type of Revi . ew: Complete Review E] Structural Only El Other Repetitive Fee Repeats Hourly 1Hr- @ El EsGill Fee $195.381 7, Comrnents: I n E itio n, tc t e'.,,'a h 10,~"f& ttYd_'-_C-1.1Grq6.n~EiVi eW . Sheetj of 1 macvalue.doc + LAND DEVELOPMENT 760-602-2750 Chris Sextbn -60i4' .,Chris,Glassem- G r6g lqya n 624 766-66i~784~~:~, -760-602 4663'e c~ris.":S,ext'oh@carl!~baidca.gov thristoph'6i.Giass;en@d"arlsO'adc6~gpv,,, j Gr~gq~y.Ryap@ibari~badca.gov,~., a~R,'iz7k"~ U n iveros"41 ind Y'Wong P, -6b- ,06 -214675 ~760-6024662; .,'Ginb'.Ruiz@,carlslb' &-a';gov,'. I nd 6iive~ps@clarlsb d- 6.0 a ca.gqv c ngOca,rlsbadc~ Ynthia,.Wo., qigqvl 1 J VAIRay..-_ e son PP2-2741, , -602-4664, , F, F, 760, - Wifty.Marshad a s 6dca.gov Do~nin'ic.Fieri@carlsbadca.%ov- Y" Remarks:': J MALEWIC.Z ADDITON PLAN CHECK NO #,.2 Outstanding issues are mark Items that conforin'to permit -d J requirements are markedi~ith'Li~_J or have intentionally been 'left blank. 1. 'SITE PLAN Pr'6~iide a fully dirnensi6ned'sit6 p!a.n drawn to scale. Show., 'M North airrow Driveway'widths __J Existing' & litopoted structures Existing or proposed iewei~ lateral =.Existing street improvements Existing or proposed water service F7 Property'lin'es sh al imension - s). ~ow El~ Submit on signed ap'pr'oved plans: Easements DWG No: Rig ht-of-way width 8~, adjacent streets Show6n,site~pl;an: :7, elev'tO Drainage patterns and'propo'se s te a ns. ShovV611 66h poihts.. NOTE PLAeE'D ON SITETLA Bli~ilding pad surface dirainage must maintain a minimum slope of one percent towards~pn adjoining street,or an approved drainage course. TO DRAIN y _k~ M AWA F 0 =ADD THE FOLLOWING NOTE: ."Finish grade will provide a minimum po* sitive drainage of 2% to,swale 1 .1 - , i THEHOUSEBY,* 5'away from building7. "". .1 ., "1 1. - V Existing p,roposed slopes, a rid-46pog ra phy -, :-', - I ~ A A~ . CITY STANDARDS =Size, location, alignment of existing or 0~oposed sewer and water service(s) that serves the project. Each unit requires a separate service;: however, second:dwelling units and apartment complexes are an~ exception. Sewer and1 water laterals should not be located "within proposed driveways, per standards. 5 (~clud'e on ~itle she ~.'F_7~ Site addres's Assessors '.~rcel number p Legal description/lot numb&_- Z __J For commerciallindustri'al.'bUildin'~ gs and. tenant, improvement projects, include:. total building square 'foot~ge witK the o6are—footade for, each different use, . existing, sewer permits showing'square footage~of different .:bses,(manufactu ring, warehouse, office,"etc.) previously approved. C4 S66 W_ all iiiistind,iJise."6f SIF ah~-Jriei~ pro~y6sed 6se bf S'F. Example: Tenant improveineriffor'350b SIF -of Warehouse to 3500 SF of office. or Lot/Map No.: LOT 669 MAP 7367 Subdivision/Tract:, LA COSTA MEADOWS UNIT 4 Reference No(s): i. E-36 Page 2 f 6 REV 6/01112 mALEWICZ ADDITON PLAN tHECK NO.# 2 Zoe. "5. -GRADING PERMITREQUIREMENTS The cbriditions that require'a ~'gra'clihg permit are, found in Section 15.16 , of the Municipal Code. =1 had6quate information available, on site- plan to make a determination on grading requirements. Inc ude4 accurate grading quantities in cubic yards (cut, fill, import export and remedial). This inf6rmationrnUst be.1i6cluded on-ifie' plans'.,If no g*rading.,is proposed write , :"NO~GIRADI,NG" ing.. P ~NQTE!, the gradin h gradih g permit.must be issued a6d r6u6 ='Gracl. er'rnit'requited; a proval obtained prior to issUan66 of a- building permit.'. Graded Pad'Certification required. (Note: Pad certification may be requiredeven, if a grading permit' is nofrequ'ii~'ed.)' 'Ail required docu I mentation must be provided to ~6ur trigineering Constrbction I'n" spector The inspectorwill then provide the engineering counter with a release for the building'permit. No grading P'- V ermit required'. Minor Grading Permit required. S'66,additional comments for. project- specific r6q6ir'ernks. 9 o. J 6. MISCELLANEOUS E RA It 8'' UG HT~0IF-WAY''kIRMIT'. is'req u i red to'do wor in, Clty,rright-of-way and/or private work N/A , a . djac . ent, to . the p I ublic,,rjght-~of-w~;. types of work include, but are not limited to: street ~. "i ~~ - ~ .'- '~ t' .- " .. , tj - , , - - i improvements," ree trirKrinirfd, driveway constr'u'cti6n, tying into public storm drain, sewerand water uti ifies.~ Right-of.-way permit required for. ~-36 F~age 4 of 6.4 REV " 6/01/12 MALEWICZ ADDITON PLAN CHECK NO # 2. 7. -STORM WATER Construction Compliance Project Threat Assessment Form com' lete. F,/ p Enclosed Project Threat Assessment Form incomplete. Requires Tier 1* Storm Water Pollution, Peeve I ntion Plan, (E-29). Please complete affac hed form and return 339 Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2 SWPPP, payment of processing fee and review by city., Post-Development (SLISMP) Compliance Storm Water Standards Questionnaire. Project is subject to Standard Storm Water Requirements. See city Standard Urban Storm Water Management Plan (SUSMP),for reference. Indicate areas of impervious surfaces (pati os,walkway, etc. and pervious areas (landscaping), Project needs to 'inco~porate low impact development strategies throughout in one. or more: of the*followi ng; Ways: Rainwater harvesting (rain barrels or cistern) Vegetated Roof Bio-retentions cell/rain garden Pervious pavement/pavers Flow through planter/vegetated or, rock drip line Vegetated swales or rock infiltrati'-n s 6 wales E] Downspouts dis1connect and discharge over landscape I Other: E-36 Page 5 of 6 REV 6/01/12 MALEWICZ ADDITON PLAN CHECKNO # 2~'. A: ell '8. WATER METER REVIEWr. - omestic (potable) Use -1 71 Mat'size meter is-required?,, I N/A' [-7 3 1- h ve automati fi' FFyl] Where a-,residential, unit is"required tc;'~ a " an c re extinguishing system, the minimum meter~ size shall be a 1" meter. f NOTE, the . con necti6h - fee, - SDCWA system - capacity charge and the water treatment d6pdcit~,chargel-will-be based on the size of the i~efer necessary,to, meet the water use, requirements. a Fokr~esidential units the minimum size meter.shall be 5/8", excep where t nti the r6side al'unit is larg&'thafi, 3,500 square feet or on a lot largeir'than one quarter.(1/4) acrO,,where,the me er size shall be W. t 9. FEES k. ave' 'in 6 uildi p' Req6iredfe6s h been entered n ermit. 4 i Drainage fee applicable Adde'-di- f square eet r 4 "' ~~, A Add6d sqy NO a-r6 footage in ast b ~ears? M yes no N') Permit N o. A Project built after-1986 yes no 00 'Impervious surface~Z 5 /C F-j yes A; no Impact u'riconstructed faci ity,,,",~, f-~ yes Elno Fire sprinklers, requi~ed, J7-7]yes--~, njo (is addition over 150'from centei~ line) Llpgrad6 I D yes 17 No fees requi~ed .10.; ADDITIONAL COMMENTS' 41 1 6, a n Storm' Water Form Aitachments: Engineerlift'Ap'plic tio Right-of-Way Application/ Info. Reference Documents E-36 Page 6 of 6 REV 6/01 /12, e- Fee Calc'ulafio'h-Worksheet'~ E N G I N E E R I N G D I V I S 10 N ***This may not represent a comprehensive list of fees due for this project.. Please'contact the Building division, at (760) 602-2719 for a complete listin' g of fees*si Project Address: PLC. Assessor Parcel No. Ctzbm, (C p. ZI-5. 460. Owner/Owner's Authodzed Agent Name: Title: Own s Authorized Agent Signature: Date: ci enc;7 S 11 N( By: Date: Project ID: Page 1 of 1 Rev.03/09 N . STORM WATER Development Services COMPLIANCE' Building Division CITY OF ASSESSMENT 1635 Fa raday Avenue CARLSBAD' 760-602-2719 B-24 www.carlsba'dc~.gov 1 am applying to the City of Carlsbad for the following type(s) of construction permit: Building Permit U Right-of-Way Permit U My project is categorically EXEMPT from Electrical Patio/Deck the requirement to prepare a storm water Fire Additional Photo Voltaic pollution prevention plan (SWPPP) because it Fire Alarm Re-Roofing ' only requires issuance of one or more of the 771 Fixed Systems Mechanical ' Sign Spa-Factory following permit types: Mobile'Home Sprinkler Plumbing Water Discharge Project Storm Water ThreatAssessment Criteria'. No Threat Assessment Criteria M My project qualifies as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it meets the 'no threaf assessment criteria on the City's Pro'Ject Threat Assessment Worksheet for Determination of Construction SWPPP Tier Level. My project does not meet any of the High, Moderate or Low Threat criteria described below. Tier I - Low Threat Assessment Criteria ill% My project does not meet any of the Significant or Moderate Thre at criteria, is not an exempt permit type (See list above) add the project meets one or more of the following criteria: - Results in some soil disturbance; and/or - Includes outdoor construction activities (such at saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling). Tier 2 - Moderate Threat Assessment Criteria 0 My project does not meet any of the Significant Thniat assessment Criteria described below and meets one or more of the following criteria: - Project requires a grading pla6 purguant to the Carlsbad Grading, Ordinance (Chapter 15.16 of the Carlsbad Municipal Code); or, - Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance Preas and project meets one or mo're of the additional following criteria: - Located within 200 feet of an environmentally ~ensitive area or the Pacific Ocean, and/or - Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to I vertical, and/or - Disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse, and/or - Construction will be initiated during the rainy season or will extend into the rainy season (Oct. I through April 30). Tier 3 - Significant Threat Assessment Criteria Ll . My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or U My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, refueling and maintenance areas: or, 0,-~ My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s)., CA~ it I certifk to the best of my knowledge that the above checked statements are true and correct I understand and acknowledge that even though this project does not require preparation of a construction SWPP, I must still adhere to, and at all times during construction activities for the permit type(s) check above comply with the storm water best management practices pursuant to Title 15 of the Carlsbad Municipal Code and to City Standards. *The City Engineer may authorize minor variances from the Storm Water Threat Assessment Criteria in special circumstances where it can be show~ that a lesser or higher Construction SWPPP Tier Level is warranted. B-24 STORM WATER POLLUTION PREVENTION NOTES 1 . ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL BMPS WHEN RAIN IS EMINENT. THE OWNER/CONTRACT OR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION OF THE CITY ENGINEER AFTER EACH RUN-OFF . PRODUCING RAINFALL. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEERING OR BUILDING INSPECTOR DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. ' - ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. ALL GRAVEL BAGS SHALL BE BURLAP TYPE WITH 3/4 INCH MINIMUM AGGREGATE. ADEQUATE EROSION AND SEDIMENT. CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. SPECIAL NOTES 'PROJECT INFORMATION Site Address: 7-62-1 a'd&ao raf-_ Assessors Parcel Number: ProjectID: -Construction Permit No.: Estimated Construction Start Date 2--- 51~PT I Project Duration 3 Months Emergency Contact: Name: ig Am NA)awLc7t. 24 hour Phone: 7b 0 731 0 2k Perceived Threat to Storm Water Quality [~;Medi Low If medium box is checked, must attach a site plan sheet showing proposed work area and location of proposed structural BMPs For City Use Only CITY OF CARLSBAD STANDARD TIER 1 SWPPP Approved By: Date: <~~ 20Z* VIV C I T Y 0 F 0 A CARLSWAD ~ STORM WATERCOMPLIANCE FORM TIER 1 CONSTRUCTION SWPPP E~-29 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov STORM WATER COMPLIANCE CERTIFICATE My project is not in a category of permit types exempt from the Construction SWPPP requirements My project is not located inside or within 200 feet of an environmentally sensitive area with a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s). My project does not require a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code) My project will not result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas that meets -one or more of the additional following criteria: 9 located within 200 feet of an environmentally sensitive area or the Pacific Ocean; and/or, . disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 Vertical; and/or 0 disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse; and/or 0 construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT ALL OF THE ABOVE CHECKED STATEMENTS ARE TRUE AND CORRECT. I AM SUBMITTING FOR CITY APPROVAL A TIER 1 CONSTRUCTION SWPPP PREPARED IN ACCORDANCE WITH THE REQUIREMENTS OF CITY STANDARDS. I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT.BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO MINIMIZE THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO MINIMIZE THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND, (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED BY THE CITY OF CARLSBAD. OWN?ER ' 4/OWNER'S AGENT NAME (PRINT) .7 (5 OWt )R9)16V1KER'S AGENT ?MME(!GNATURE) DAT E E-29 Page 1 of 3 REV 4/30/10 3 j -0 5F ET 5 0 3 CD 0 CD CC CD il a) SU 0 :3 :3 ~r CD (0 CD 0 P 3 -a 3 =4 CD CD 0 C-D 3 3 c.,) CD cD C " Cr 0 ao' wo(2. :T 0 E,P — , :3 CD CD :3 E, 3 —. Ve =r 0 cu < CU CD 0 K 0 FD. or -, -a 5-0, 9. 0 CD CD CD (a =3 Q OD 0 0 U) - _--a = -0 K <MOS085 RL -U M 0 X 6 Er CL 'C-D E-r (a CL En n) CL CD CD M .0 -0 c) 7ff -0 s- au) o R), :3 0 = 91 — — 3 x W a m -o 2 :3 CD (D CL 2. cD CL a) W ry ~O CD C) (D 6- 0 0' (D :3 (:03 CcnD 00) 0 C cD 2 3 cD :3 S. 3 g Er- CL R M ,a) 0 CO .1 'a, W C W .3 tu :3 3 f2' C En, :3 CD to CL M fu 0 q Er Sr M, > " M 0 CD 0 CD - M M g ;0, r lun, :5. E; Q,) (M x - — 20 0 CD M 0 @ lu --1 :3 0 :E 5 en 3 =r — 5 Rr CD CA_ -a M, C-D a) ~ r- CD CD CL Z 1 0 CO WX CL 0 x 3 M ;: 0 > M-0 :r cn :03) 3 M CD XSU (D 0 a) x ~2. :3 '< 5' (D C-) 5(0 0 0 (D 0 5- CD a) a -0 0 o a- E; :3 :3 m :3 — — -< W ET 5, 0 :,L a) OcD X, CWD 00) 0 K — = 6 = CU -0 5* 0 =r = 25- :3 (n 0 = CD.0 1Z CL E0 -a = Er ::r CD CL 0 Er -0,0 =,r CD L 0 ID cu :3 CL Cn CO CaL O= WO 0 (D ID o @ CL 0 CO 0, (D c q U) 5 ~ C/) =r C1. Fr OF x CD ~~ CL CD !-5: CD — — — a) Z lu 5. :r >.F~ 0 :3 o 2 E-r C-D 0 0 CD =r C Cr C 0. = 0 — > 0 0 x :3 :r CD o CD 0.0 W 5' a R- ? 0 515 CD C- E-r -n CWD CD CD @ !R CL CL 0 CD GO (2 500 a' (D 00 (D , OX (n Q) CA q a 0~ .6 Er :E a) 2 0 o C :r ~r =r CD =r 0 5-0 CD CU 3.0 :3 C13Z U3- 1 0 0 CL > v79 a — (D ?. 00 (a a 0 0 F" CD 000 3 05) cu * - =gE&,< r > 3 cc, 5L 9 R D CO CD =r 0 =r CD @ (D 0 ~3 M (D Cn - M — " 0 5. Cn 104 0 0 0i 0 = IU o > r, , o E; CD go vi, = 15. CD M CML a 3 CD = CD :E 0 0 cO 3 M Q) Z 0 R OM C) =r :3 =r CD -0' 0 M 5P. 0 a= @ < a " =r 0 CD 0 0 M 5. CD 0, 0 CD rA, :3 (D < 5F a CD :E. M CO (D W X m 0 lu 0 >0 0 W ODOCMWM U) ck) (D N :3 M 0) ~n C 0 , -0 , (C-,) .0 cp 0 (D > -n -a :3 CD 0 0 0 =3 0 :3 OX R 0 U) 10 W a — M r- 0 2. 9 C-, M 6 cao 5. 2:,, :3 - > C U, LO (n 5 a M 2 0 ;L :P .0 W 0 n 4Z m in 2. 0 (5 (a 0 M > CD Cn 0 0 W E~ CD — x — 0 to 0 Cn a 0 :03 :T W 0 > (D U) E; :3 M :3 > 0 < W 0 — Z 0 0 M 0 :3 M 0 0 M EC-7 Geotextiles & Mats m I EC-8 Wood Mulching 0 a M 0 EC-9 Earth Dikes and E = 00 Drainage Swales 0 0 EC-1 1 Slope Drains 0 SE-1 Silt Fence SE-3 Sediment Trap SE-4 Check Dam 0 CL A SE-5 Fiber Rolls ID SE-6 Gravel Bag Berm 0 SE-7 Street Sweeping and W Vacuuming E SE-8 Sandbag Barrier V SE-10 Storm Drain Inlet Protection TRA Stabilized Construction' Ingress/Egress :;I 0 0) TR-2 Stabilized Construction Roadway U) NS-1 Water Conservation Practices Z NS-3 Paving and Grinding 0 I. I Operations NS-7 Potable Water/irrigation NS-8 Vehicle and Equipment ii; Cleanono WMA Material Delivery and Rtnranp WM72 Material Use WM-3 Stockpile Management F,W WM-4 Spill Prevention and Oto = ID 03 Control 0 'WM-5 Solid Waste 0 go Mananement W CL WM-6 Hazardous Waste fu Mana nement WM-8 Concrete Waste Mahanpmpnt W, r DIVISION ', Developinent Service~ *4 BUILDING PLAN CHECK 'Planning Qivisi6n' :C11 -f Y 1635 Fara~day Avenue',~' .., ., -1 _~.. ~ , I REVIEW CHECKLIST , t K -A Q- A . . , . - . 1 (760) 602-4610- `28 A SD/A ~P- W 'Yov R L D ww carlsbadca.L r DATE: 1-15-16~ F PRO,JECT NAME: ROJECTID: I; It -:2882', SET#: 2: ADDRESS: 2624 Obefls'bo P1 APN: 215-460-26-00 PLAN CHECK NO: CB 15 This plan"check review, is.com plete and has beenAPPIR - OVED by tl~e Division., By: Chrls'Sextoh 1 A A Final Insoectioii by.the Planning Division-is required ED Yes Z,No You -may also. have.corrections from one or more,of the divisions listed belovVi'Approval - - from"these divisions may be requked -prior to the issuance -of a.-building permit. Resubmitted plans should include corrections', from all ~ivisions. This plan check review is NOT COMPLETE. Items missing or incorrect are, listed',:on t e ns as requ the attached checklist. Please'rdsubmi ame,nd'd plai i red. 4,1 Plan Cli.eck.Comments have been, sdnt t6:, trav'vIsdeaI@yaho6.corn- For questions or clarifications on the'attached bheckl ist. please contact the following reviewer as marked:, ky 760-602-2773. Lin da.Ontiveros@carlsbadca.gov 760-602-4664- Do inic.Fieri@carl' M sbadca.gov Remarks: PLANNING ENGINEERING FIRETREVENTION .760.602-4610 .76M02-2750 7 6&~62-4665- ~k Chris Sexton ris'Glass~ein Greg Rya n 760 -602-4624 -6 -2784 7160 02 760-602-4663 Chris.Sexton@car1sbadcaAov Christop~er.Glas~en@6ar'lsbadc-a'.gov Qre9or)LRyan@car1sbad6a:90V" F-1 Gina' Ouii.', VaIR ay Mars hall -71 .. --C i ndy Wong -760-662-4675' .760-602-2741' '760-602-4662 Gina.Ruiz@carlsbadca.gov VaiRay.Marshall@carisbadca.gov! Cynthia.W no-6c6ilsbadca'gow'. 'Lind'a O'htiveros Dominic Fied'*_ Plan Check No. CB 15-2982 Address 2624-Obelisco PI Date 1-15-,16 Review # .2 Planner Chris Sexton Phone (76 )602 -4624 APN: 215;.46046-00 Type of Project & Use: Net Project Density; DU/AC Zoning: RA-1 5,000.General Pl4n: RLM.Facilities Management Zone: 6 CFD,(in/out) #_Date of participptioh-... - Remaining net dev acres: J (For'non-residential development: Type of land use created by this permit- 'REVIEW #: 1 2 3 Legend: 0 Item Complete El *Item incomplete - Needs youraction- N El F1 Environmental RevieW Required: YES El NO El TYPE- DATE OF COMPLETION: Compliance with conditions of approval? If not, state, conditions which require action, Conditions of Approval: N El F1 Discretionary Action Required: YES E] NO TYPE APPROVAL/RESO. NO.'' DATE PROJECT NO. OTHER RELATED CASES: Compliance with,conditions or approval?. If'not, state conditions. which require acti' on. Conditions of Approval: E El r .1 Coastal 2one Assessirridn't/Compliance. Project site located in Coastal Zone? YES F1 NO F]. CA Coastal Commission Authority? YES NO F1' If California Coastal Commission Authority: Contact t h 6m 'at 7-7575 Metropolitan -Drive,, Suite 103,. San Diego, CA 921084402; (619) 767-2310 Determine status (Coastal Permit Required or E~empt): ~n `E] F1 Habitat Management Plan Dat Entry C' F a ompleted?. YES —1 NO F1 If property:has Habitat Type identified in Table,1 1 'of HMP, complete HMP'Permit application and assess fees in Permits,Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens., HMP Fees, Enter',.Acres of Habitat Type. im pacted/ta ken, UPDATE!) N El :n Inclusibnary Housing Fee required: YES F] NO.F] (Effective date of Inclusionary Housing Ordinan.ce - May 21, 1993.) Data Entry. Completed? YES El. NO (A/P/Ds, Activity Maintenance, enter~: CB.#,, toolbar, Screens, 'Housing 'Fees, Cbbstruct Housing Y/N, Enter Fee, UPDATE!) N El El Housing1racking Form'(form P-20) completed YES E] NO.[] N/A E] P-28 Page 2 of 3 07/1 Site Plan: N El, F-1 Provide a fully dimensi.onal site plan,&awn to, scale. Show:: Nbith' arrow, property lines- :easements, existing and proposed structures, streets, existin' g street improvements, right of-' way width, dimensional setbacks and existing'topographical lines (i'ncludin* all side 'and rear 9 yard'slopes). Provide legal description of property.and 6ssess,or's parcel number.,'. City Council Policy 44 Neighborhood Architectural Design Guidelines.. F1 FT. p a A plic*bility: YES El NO FT 1Z :El Projectcomplie's: YES F] NOD Zoning:' F-1, 0 F-1. 1. Setbacks: Front: Reouired.20'. Shown.20' lnterior~Side. Req u i red. 10' Shown 10',' Street Side:.. Required. Shown Rear: .,Required 20' Shown, 20' Top of slop e: 'Required'N/A. Shown H E]; F :2. Accessory structure setbacks: Front:. 'Required Shown. , Interio,r*Side- Required.' Shown Street Side: . Required Shown Rear: Req6i -red Shown Structure separation: Required Shown LotrCove rage: Required'<40% Shown ~~40% El z 0 Hei ht: :Required <35' Shown <35' 9 0 El F-1 5,. Parking: SpacesRequired 2, Shown 2 c a (breakdown by uses for commer i I and industrial projects required) Guest Spaces Required - Shown L-1 LJ R- Additional Comments 1)_ Please,brovide the topo' -grelphy, of the* lot so staff can continue the review of,the proposed addition.' TO ISSUE AND ENTERED APPRbvAL INTO COMPUTER Chris Sexton- DATE 1-15-16 P-28 Page 3 of 3 07[11 CA 0 y f Cl;ir sbad ,RESIDENTIAL GREEN BUILDING CODE STANDARDS MANDATORY MEASURES CERTIFICATION CHECKLIST B-51 Develooment Services Building Division 1635 Faraday Avenue . ~60-602-27 19 www.carlsbadca.gov Thisform, signed and cbmpleted, and receipft fok, the`r'' ta ',.Pqyc1edmater"'1sshah'be' submitted to the Building. Insijector pricii tofinafins&ction. _V; Site D6ve; Iobr'fidnt',-;,` P WN, t Mandatory 4.106.2 A plan is developed and implemented to manage storm water drainage during construction. X 4.106.3 The site shall be planned and developed to keep surface water away from buildings. X Construction plans shall indicate how site grading or a drainage system will manage all surface water flows. I Ktn -Efficienc- y _ergy. 4.201.1 Low-rise residential buildings shall meet or exceed the minimum standard design required by .(X) the California Energy Standards. Vat4~,twlciency_ -and Conservation Indoo_rWat6( 6~' 4.303.1 Indoor water use shall be reduced by at least 20 percent using one of the following methods: (X) Water saving fixtures or flow restrictors shall be used. 7/01/2011 A 20 percent reduction in baseline water use shall be demonstrated. 4.303.2 When using the calculation method specified in Section 4.303.1, multiple showerheads shall not (X) exceed maximum flow rates. V01/2011 4.303.3 Plumbing fixtures (water closets and urinals) and fittings (faucets and shower heads) shall X comply with specified performance requirements. 7/01/2011 ~butdoo-r*a'ter Ui~e - 4.304.1 Automatic irrigation systems controllers installed at the time of final inspection shall be weather- (x) 'based. Enhanced Dbr'ability,apo Reducdd;Mairitenance 4.406.1 Joints and openings. Annular spaces around pipes, electric cables, conduits or other openings in plates at exteriorwalls shall be protected. against the passage of rodents by closing such openings X with cement mortar, concrete masonry or similar method acceptable to the enforcing agency. ,Constructioii*a.~te. Management Plan A minimum of 50 percent of the construction waste generated at the sit ' e is diverted to recycle or X salvage. Recycled material receipts from approved recyclers must be attached to this form. 4.408.2 Where a local jurisdiction does not have a construction and demolition waste management (X) ordinance, construction waste management plan, perform B-59, shall be submitted for approval to the. ,enforcing agency. Maintenah1ce and.Ope-rati6n.~~,~z_ ...quilding 4.410.1 An operation and maintenance manual shall be provided to the building occupant or owner. (X) brivir6hmeh tal Qualit y 'Fi~epla6es,,', - 4.503.1 Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed woodstove or pellet stove shall comply with US EPA Phase 11 emission limits where applicable. Woodstoves, pellet stoves and fireplaces shall also comply with applicable local ordinances. B-51 Page 1 of 2 Rev. 11/15 !171,at ntp,,5fitr6l~ 4.504 ' .1 Duct openings and other related air distribution component openings shall be covered (X) during construct ion. 4.504.2.1 Adhesive, sealants and caulks shall be compliant with VOC and other toxic compound (X) limits. (X) 4.504.2.2 Paints, stains and other coatings shall b; compliant with VOC limits. (X) 4.504.2.3 Aerosol paints and coatings shall be compliant'with product weighted MIR limits for ROC and other toxic comp'ounds. (X) 4.504.2.4 Documentation shall be p , rovided to verify that compliant VOC limit finish materials have been used.' (X) 4.504.3 Carpet and ca~pet systems shall be compliant with VOC limits. 4.504".4.50 perc~nt of floor area receiving resilient flooring shall comply with VOC-emission limits (X) defined in the Co'llabo'ra-tive for High Performance Schools (CHPS) Low-emitting Materials List or be certified under the Resilient'Floor Covering Institute (RFCI) FloorScore program. , (X) 'board, 4.504.5 Particle medium density fiberboard (MDF) and hardwood plywood used in interior finish systems shall comply with low formaldehyde emission standards. Y1 61 ON 4.505.2 Vapor retarder and capillary break is installed at slab on grade foundations. (X) 4.505.3 Moistur6 content of building materials used in wall and floor framing is checked before (X), enclosure. 41, A: 4.506.1 Exhaust;fans which terminate outside the building are provided in every bathroom. (X) Ft6Mf6 tA ~j A 'i" 4.507.1 Whole house exhaust fans shall have insulated louvers or covers which close when the DO fan is off. Covers or louvers shall have a minimum insulation value of R-4.2. 4.507.2 Duct systems are sized, designed, and equipment is selected using the following methods: (X) 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent. Size duct systems according to ACCA 29-D (Manual D) or equivalent 3. Select h6ating and cooling equipment according to ACCA 36-S (Manual S) or equivalent. a ohs t"i 116F- S" 1Ahsjject&,..QUb1if 6 :_pecia 702.1 HVAC system installers are trained and certified in the proper installation of HVAC (X) systems. 702.2 Special inspectors employed by the owner must be qualified and able to demonstrate (X) competence in the discipline they are inspecting. 1, as the professi6nal responsible for this'project~ certify that, to the best of my knowledge, the mandatory item's ` i I listed on this form have been incorporated into the project in order to comply with Title 24, Part 11 of the 2013 California Green Building Standards. All receipts for recycled materials have been attached to this form.. Project Add r6ss:~,& Ne,\ 11::~ WO —Plan Check Numbed- .Print Name: 441 V~ %Q' )Pb) C'2_ Signed: Id I License Number: t n 13751 Page 2 of 2 Rev. 11/15 i of'Ca Isbad 1635 Faraday AY Carlsbad', CA, 9,2008" 09~12'2016 Plan Check-R6ViSi0h 'Permit No: PCR1 6132 Iding hs~ectipnl Re Bui quest L ine (760) ,602-2725 -Job Xddress: 2624.OBELISCO'PL CBAD. Permit Type- PCR Status: ISSUED Parcel 'No: 2154602600 Lot #: 0 , **Applied:,' .07/06/2016 Valuation: $0.00, Con~truction Type:- 58 -Entered By: JMA, Reference #: ~Plan.Approved: 09/12/2016 PC #:. CB152a82 Issued: 09/12/2016 Project Title: MALEWICZ: CHANGE TO RAISED Inspect 'Area: FOUNDATION' Applicant': Pwner:. TRAVIS DEAL MALEWICZ FANilLYT'RUST' 06:-26'-'87n 1264 0 B*EL'I SCO PL CARLSBAD CA 92009 949-426-1386 Plan,Che6k Revision* Fee _$125.06'_r ire moo F -Ex~peidit~d Plan Review" Additional Fees $0.00 Total Fees: $1.25.00 Total Payments To Date: $125.00, 'Balance bue: $0.00, 0 PLAN CHECK REVISION Development Services. .yof Building Divisio'w APPLICATION 1635 Faraday Avenue' 760-602-~716 Cd1sbad B-1 5 - I www.carlsbadca.gov Plan Check Revision No. 2~ Original Pliin'Ch'eck No.' 2-88 2_- Project Address D~te Ph Fax Contact Email _[MicQtS rl Contactl Address city CA,?d~b^o zip General Scope of Work foe Original plans prepared by an architect'or e I ngineer, revisions'must be signed & stamped by that'person. Elements're-vis'ed: Jej~Plans F~ calculations -E] Soils F-] Energy EJ Other 2.. Describe revisions in detail List page(s) where each revision is, shown' List revised sheets that replace -existing sheets L I SLAB rcoT IN q DETA'~'~_ 'T_0 PA L(;,PP'. ADDED AtZG~A C-OA4q F_ Does this revision, in any way, alter -the exterior of the project? 7Ye~ No, Does-this revision add ANY n~w- floor area (s)? - OYes P~t, No' Does this 'revision ffect any fire related issues? Yes No is' this a compi set? Yes ~Ie~.Signature 1635 lParaclay)~ve ue arlsba4 CA §2008 014-/60-602- 2719 Fax: 760-602-8558 Email: building9carlsbadca.gov wwwcarlsbadca.g .1 Carlsbad 15-2882 Rev 1 (PCR16-132) s ` E I C G1 orporation In Tartnership ~With governmentfor Building Safety DATE: 9/8/16 LI APPLICANT Ijd1j R I S. JURISDICTION: C rlsbad Q PLAN REVIEWER a FILE PLAN CHECK NO.: i.15-2882 Rev 1 ~(PCR16.132) -'SET:,II -PROJECT ADDRESS: -2624 Obelisco Place PROJECT NAME: Revision* to Malewicz SFD Addition, Remodel and. Patio Cover F-1 The plans transmitted herewith, have beencorrected where necessary and substantially u -code com plywith,thej risdiction's, The plans transmitted herewith^ will substa* ntially comply With the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building. department staff. The plans transmitted herewith have significant, deficiencies identified on the enclosed check list and should be, corrected and resubmitted.fbr a, complete recheck. F1 The'-check list transmitted herewith is for your information. The plans are being -held at Esgil Corporation until corrected plans are submitted for,recheck. F-1 The applicant's copy of'the check list.is enclosed for the jurisdiction to forward to.the applicant contact, person. F-1 The applicant's copy of the check list has been to: EsGil Corporafion staff did not'advise the'appli,cant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the~ plan check has been completed.; REMARKS: The foundation plan on the originally approved sheet,4 needs to be r 'crossed out and the red-clouded note added'on that,sheet,in.the originally approved Owner set as I have done. in this set. 2) New sheet 413 needs to be, added.to the Owner set of the approved plans to- make a c6rnplete,,appro.ved revised set (I have already'addedit to the approved City set). Thank you' By: Tamara Fisicher Enclosures:, EsGil Corporation D GA El EJ''El MB F! PC 9/1/16 C orpo' ti ra oh 'in (Partnership with governmetitfor-Building,Safety DATE:'* 7/13[16 EI 6PPLICANT .J~rJLIRIS. JURISDICTION: Carlsbad El PLAN REVIEWER FILE PLAN, CHECK NO.-:. 151-,2882 Rev I (PCR16-132) SET:-1 -2624 Obelisco Place PROJECT ADDRESS.. .,PROJECT NAME: Revision to Malewicz SFD Addition, Remodel and Patio, Cover F-1, The plans transmitted herewith have been. corrected 'Where necessary and substantially com ply. with the jurisdiction's c6des. The plans t'ra.nsm'itted'herewith will subsia,htially comply with: the-j u risd iction's - codes when minor deficiencies identified -below. are resolved and checked by building, depc irtment staff. `7he plans iransi~nitted herewith have significaint deficiencies identified on the -enclosed check,list and should be corrected and resubmitted, for a complete, recheck. The check list transmitted'hbrewith is for your information., The plans ~re being held'at E' s' gil Corporation until corrected'plans a~e submitted for recheck.' The appiicaht's copy of the check list'is'enclosod for the jurisdiction -to forward to the applicant contact person. The applicant'.s copy of the.check list has been sent to: Travis Deal- 'EsGil Corporation staff Aid not advise the applicant that theplan -check- has*been'compleked. EsGil Corporation staff did advise the applicant that the plan-check.has been completed. Person contacted: Tr vis Deal^ 949 426-1386 a Telephone -ate c./ , on cted.-41 i *Pc~ Ema.il-,.travisdeal@yahoo.coi*h- ail Telephone Fax In Person- F-11',REMA'RKS: By: Tamara Fis~her Enclosures: EsGil Corporation GA' El, ES Ej IVIB El. PC 9 1 320 Chesapeake Drive,' Suite 208 San Diego, California 92 123 (858) 560-1468 Fax (858) 560-1576 Cirlsbad 15-2882 Rev 1 (PCR16432) 7/13/16 - PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND! DUPLEXES PLAN CHECK NO.: 15-2882 Rev 1 (PCR,16-132) JURISDICTION.- Carlsbad PROJECT ADDRESS:. 2624 Obelisco Place STORIES: 2 REVISIONS HEIGHT: (Ekisting) N/C REMARKS: DATE PLANS RECEIVED BY DATE PLANS RE'C'EIVED BY JURISDICTION: ESGIL CORPORATION:- 7/8/16 DATE AITIAL PLAN REVIEW PLAN REVIEWER: Tamara Fi'scher COMPLETED:' 7/13/16 ,FOREWORD (PLEASE READ)-. This plan review is,lim ited t o the technical requirements contained in the. California version of the International Residential Code, International'.Building Code, Uniform, Plumbing' Code, Uniform Mechanical Code, National -Electrical Code and state laws regulating energy conservation, noise attenuation and,,accegs for the disabled. This plan review is based on regulations enforced by the B U ilding Department. You may have other corrections based on laws and ordinan,ce. by the' Planning Department, Engineering Department, Fire Department or other departments. Clearance frorn those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2013 editioh,of the California Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC, 2012 UPC, 2012 UMC and 2011 NEC. The above regulations apply, regardless of the code editions ado~ted by ordinance~ The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4'of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law.. To spLied up the recheck process, Olease note -on -this list (or a copy) where each correction item has,been addressed, L e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit th6 revised plans. Carlsbad -15-2882 Rev 1 (PCR16-132)- 7/13/16 make all corrections, as requested in the correction list. Submit FOUR Re Gemplete sets ef pIaRG fGF GGr~mem--i-allind-istrial pi:(~eGts-i(THREE sets ' of plans for residential pi~ojects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad, CA 92008,'(760)~602- Carlsbad Building Department,, 1635 Faraday Ave.', 2700. The City will route the plans to EsGil Corporation add the Carlsbad Planning, Engineering.and Fire Department~. Briryg,TWO corrected set of plans and calculations/r6ports to EsGil Corporation, 9320. C hesa pea ke.'D rive, Suite 208, San Diego, CA 92123, (~58) 560-1468. Deliver the ~remaining set(s) of Olans and calculations/rep'orts directly to theCity of Carlsbad Building- Department for routing to their Planning, Engin6ering and Fire Departments.' NOTE: -.Plans that are submitted'directly to EsGil Corporation onlyyvill not be reviewed by the City Planning, Engineering and Fire Departm6nts until review by EsGil Corporation is complete; PLANS 1. All revised sheets of plans must be signed ~by the person responsible for their preparation. (California Business,and Professions Code). -2. All rev ' ised sheets showing -structural information. shall be signed and sealed by the California state];1censed engineer or, i architect *of'~ecord (Mr. Young). Busin ssi (California e,ss and Profe . ons Code). Please.add all missing information from the original foundation plan on the revised. foundation plan. '(ie.. existing footings,~.new patio slab and slab edge detail reference, new pad'footihgs (and their-detail reference),'note regarding soil engineer inspection r~qpiremenfs, etc.) Specify under floor access to have a'minimum size of 16".x 24". Section R408.4. Provide a letter from-the soils engineer confirming that the, revised foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the const~uction documents. At detail 1/4B show.plywood S'hearwall edge nailing into both plates and specify the sPacing,of A35s. It looks, like per the,shear walls called 66t at that location, A35 spacing would need.to be 16" o..c..,makimum. CONTINUED Carlsbad 15-.21882 Rev 1 (P.CR16-132) 7/13/16' MISCELLANEOUS 'To speed up the review process, note on this list (or a copy) where each correction item has been'addr'esseld, i.e., plan sheet. note or detail number, calculation page, etc. Pl.ease.indicate here. if any changes have been made to the plans that are not a result of corrections from this list. If there are other changbs,* please briefly describe them and where they are located, in the pla.ns. Have changes been made to the lans not resulting from this correction* list? Please p -indicate: Yes Ll No Ll The, jurisdiction has contracted with Esgil Corporation located at- 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to, perform the plan review for your. project. If you have any questionsregarding these, plan review items', please, contact Tamara. Fisc'her at EsGil Cor oration.- Thank you. p Carlsbad 15-2882 Rev 1 (PCR16-132) 7/13[16 [DO NOT PAY- THIS IS NOT AN INVOICE] k VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: -15-2882 Rev 1 (PCR16-132) PREPARED BY: Tamara Fischer DATE: 7/13/16 BUILDING ADDRESS: 2624 Obelisco Place BUILDING OCCUPANCY: R3 U BUILDING PORTIOW AREA Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE Revisions Air Conditioning., Fire Sprinklers TOTAL VALUE jcb 113y Ordinance Jurisdiction Code Bldg. Permit Fee by Ordinance W "I Pl~n theck Fee by Ordinance $125.00] Type of Review: F1 Complete Review Structural Only [—]'Repetilive ee C1 Other 1 Hr. @ Repeats EsGill Fee $100. 00 $100.001 Based on hourly rate Comments:. Sheet 1 of 1 macvalue.doc +