HomeMy WebLinkAbout2625 Colibri Ln; ; CBR2019-0220; Permit(city of
Carlsbad
Residential Permit
Print Date: 02/22/2019 Permit No: CBR2019-0220
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
2625 Calibri Ln
BLDG-Residential
2155352200
$8,773.14
Work Class:
Lot#:
Reference#:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Deck Status:
Applied:
Issued:
Permit
Finaled:
Inspector:
Closed -Finaled
01/29/2019
02/14/2019
TFraz
Plan Check#:
Final
Inspection: 2/22/2019 9:35:00AM
Project Title:
Description: PARYLAK: 438 SF DECK (CIT'/ STANDARD)
Applicant:
PRO DECK CONSTRUCTION
ANDREW YORK
877 Avenida Abeja
San Marcos, CA 92069-7322
858-663-1599
BUILDING PERMIT FEE ($2DOD+)
BUILDING PLAN CHECK FEE (BLDG)
SB1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
Total Fees: $182.49
Owner:
JAMES PARYLAK
31 Lamphere Rd
WATERFORD, CT D6385-3446
Total Payments To Date: $182.49
Contractor:
PRODECK CONSTRUCTION
877 Avenida Abeja
San Marcos, CA 92069-7322
858-224-3325
Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
$0.00
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-6D2-2700 I 76D-602-8560 f I www.carlsbadca.gov
$106.09
$74.26
$1.DD
$1.14
(cicyof
Carlsbad
RESIDENTIAL
BUILDING PERMIT
APPLICATION
B-1
Plan Check Q:662Ql<j'-(),;J:lb
Est. Value $ gt 913 llf
PC Deposit ---------
Date ~f_-....,:;z'------'q_._,(_q.,__ __ _
Job Address 'J,4Z-5 (,.()L,-\"W-\ ~ Suite: ___ APN: 2-{5-555 -'2..'2,-bO
CT /Project#:, __________ Lot#: \ ?':) Fire Sprinklers: yes/ no Air Conditioning: yes/ no
BRIEF DESCRIPTION OF WORK: ,A-1/b Y :f ffl(.tt@ Da\<._ ~ :'{:ffl\ r,.-_s.
Addition/New: _____ Living SF, o/'D Deck SF, ____ Patio SF, ___ Garage SF
Is this to create an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __
D Remodel: ____ SF of affected area Is the area a conversion or change of use ? Yes/ No
□ Pool/Spa: ____ SF Additional Gas or Electrical Features? ____________ _
□ Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground, Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No
Panel Upgrade: Yes/ No
D Reroof: ___________________________________ _
D Plumbing/Mechanical/Electrical Only: ________________________ _
D Other: ___________________________________ _
APPLICANT (PRIMARY CONTACT)
Name:~~~
Address:b \J{ft-7--iil1\'L.-:~= -• Cfc•., 9'-""l
Email: ~-Ctll'-\
DESIGN PROFESSIONAL
Name: _________________ _
Address: ________________ _
City: ________ State: ___ .Zip: ____ _
Phone: _________________ _
Email: _________________ _
Architect State License: ___________ _
PROPERTY OWNER
Name:,-tJVI ~ g@j ~
Address:2b2--$ c.ct--\ 1:>jzjt!kl'€
City: ~ State: cA: Zip: "wm
Phone: ___________________ _
Email: ____________________ _
{Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demoli~~ai'?an/sf!u'iie~ tJits
issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law
{Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she ls exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}).
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
B-1 Page 1 of 2 Rev. 06/18
( OPTION A): WORKERS'COMPENSATION DECLARATION:
I hearby affirm under penalty of perjury one of the following declarations:
□ I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued.
sa1' have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the p ormance of the work for which this permit is issued.
My workers' ~p~~sation insur~~rrier and policy number are: Insurance 9>m17any Name: Nb
Polley No. -f"IQNV~ X-.,1 Expiration Date: -ijt-opt-0( ~
□ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage Is unlawful, and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, In addition the to the cost of compensation, damages as provided for In Section 3706 of the Labor Code,
Interest and attorney's fees. ~ {) fl ~ 1
CONTRACTOR SIGNATURE: ~~=""-"=~:..::'-'--~lf"=:.....J,...:.._.= _______ □AGENT DATE: \/t>'l.,/4-o(1
( OPTION B }: OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's license Law for the following reason:
□ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and who does such work
himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
□ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's license law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's license law).
□ I am exempt under Section ________ ,Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No
2. I (have/ have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number):
4. t plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/
contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work):
OWNER SIGNATURE: __________________ □AGENT DATE: _____ _
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name: _____________________ _ Lender's Address: _____________________ _
ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
APPLICANT CERTIFICATION:
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP
HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF
THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized
by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time
after the work is commenced for a period of 80 days (Section 106.4.4 Uni m Building Code).
APPLICANT SIGNATURE:
1635 Faraday Ave Carlsbad, CA 92008
8-1
. 760-602-2719 Fax: 760-602-8558
Page 2 of 2
DATE: _\,_/ v_,y'-zn___,_11..___
Email: Building@carlsbadca.gov
Rev. 06/18
PERMIT INSPECTION HISTORY REPORT (CBR2019-0220)
Permit Type: BLDG-Residential Application Date: 0112912019 Owner: JAMES PARYLAK
Work Class: Deck Issue Date: 02114/2019 Subdivision: CARLSBAD TCT#73-29
Status: Closed -Finaled Expiration Date: 0812112019 Address: 2625 Colibri Ln
Carlsbad, CA 92009-4304
IVR Numbor: 16752
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete
02115/2019 02/15/2019 BLDG-11 083958-2019 Passed Tim Frazee Complete
Foundatlon/Ftg/Pier
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
02/22/2019 02/22/2019 BLOG-14 084383-2019 Passed Tim Frazee Complete
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Final 084384-2019 Passed Tim Frazee Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Structural Final Yes
February 22, 2019 Page 1 of 1
{ City of
Carlsbad
RESIDENTIAL
DECKS
B-4
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
B-4
A Building Permit is required for residential decks more than 30" above grade and must comply with
the Zoning Ordinance, including building setbacks, structure separation requirements and lot coverage.
This hand out describes what plans are necessary to secure a deck permit. To assist you, there is a
sample of a plot plan, span tables for joists, girders, and beams, and there is a footing schedule for
foundation requirements. There are also connection details to use for typical connections. If you design
the deck yourself, or if your deck is free-standing or outside the table limits in this handout, please
provide a foundation plan, framing details, and other details and elevations to show the extent of the
proposed work. A complete structural analysis may be required for decks outside the scope of this
handout.
If you use the attached tables and plans please submit:
1. Two Identical Site Plans showing:
a. Property lines with dimensions.
b. Proposed deck and stairway (if applicable).
c. Distances from posts to property lines.
d. All existing structures on the property.
e. Indicate the dimensions of the deck and the total deck square footage.
f. Any easements on the property.
g. Percentage of lot coverage.
2. A Building Permit Application with the following:
a. Name of the property owner.
b. Home Phone Number
c. Site address, assessor's parcel number, lot number, subdivision name or number.
d. Contractor's name, State License Number and City Business License Number; or an
Owner-Builder Declaration Form (Available at the Building Division Counter).
e. Signature of Applicant
If you are applying for a building permit in a subdivision with a homeowner's association, you
should secure architectural review prior to proceeding with the project. The City does not enforce or
specifically review provisions of homeowners' association CC&R's. HOA requirements may be different
than City requirements.
If you are applying for a building permit in the Coastal Zone, you may need a Coastal Development
Permit or an exemption. Contact the Planning Division for details. A Coastal Zone map is part of this
handout. If you are applying for a building permit in a subdivision with a homeowner's association, you
should secure architectural review prior to proceeding with the project. The City does not enforce or
specifically review provisions of homeowners' association CC&R's. HOA requirements may be different
than City requirements. If your home is part of a Planned Unit Development or a condominium, please
see text of this handout.
Page 1 of 6 Rev. 03/09
SETBACKS FOR R-1 PARCELS
FRONT V ARO • 20' from front
property lne
INTERIOR SIOE YARD -10% of
lot width '41 to a maxnun of
10'
STREET SIDE Y ARO • 1 O'
REAR V ARO -20% of lol width
'41 to maicwoom of 20 feel
MAX. LOT COVERAGE. 4()'l(,
Contec:t the ~ming Oepartmert
f,x Information on corner tots or
lots wilh UBASU&I conf'9Xallons
Md for Information on l'lllnned
Communlies, accessory
structures, and building
heights.
The telephone numbef-fa, the
PIJonninn OH......tmert Is
602-4610.
10%
20%ofLOT
REAR YARD 'WIDTH TO A
MAX.OF20'
EXISTNO RESIOENCE
~ ~ DRAl'IAOE 2'lfo MIN. --------1-
20'
STREET
\
J
Minimum Square Footing Sizes (inches)1•2
Post Joist Span (in feet) Spacing ~
4 6 8 10 /'12/ 14 16
-
4 12 14 16 18 20 20 22
6 14 16 20 22 24 24 28
8 16 20 22 24 26 28 30
10 18 22 24 28 30 32 34
/12 _.......D 20 24 28 32 (32) 36 36 -
1. Assumes 1,000 psf soil bearing capacity
2. The minimum depth for all footings is 12 inches into natural grade
8-4 Page 2 of6
18
24
30
32
36
38
Rev. 03/09
Allowable Joist Sizes
Joist Span Joist Span Joist Spacing Size of
Douglas Ar Redwood Joist
6'3" 6'3" 12"
5'6" 5'6" 16" 2x4
5'0" 5'0" 24"
9'9" 9'9" 12"
8'9" 8'9" 16" 2x6
7'9" 7'9 24"
12'9" 12'9" 12"
11 '9" 11'9" 16" 2x8
10'2' 10'2" 24"
1fi'5" 16'5" ~ Gx}Y {15'0"~ 15'0" '
ITO" 13'0" '
20'0" 20'0" 12"
18'0" 18'0" 16" 2 X 12
15'10" 15'10" 24"
22'9" 22'6" 12"
19'9" 21'0" 16" 2 x14
16'0" 17'0" 24"
1. Assumes a live load of 40 psf and a dead load of 8 psf.
2. If joists are within 18" of grade, use pressure treated Douglas Fir-Larch or Foundation Grade Redwood
3. Assume F(b}=825 psi, F9v)=90 psi, and E=1,200,000 psi for D.F. #2
4. Assume F(b)=925 psi, F9v)=80 psi, and E=1 ,200,000 psi for Redwood
Allowable Beam Sizes
Joist Span (in feet)
Post --Spacing 4 6 8 10 /12 / 14 16 -
4 4x4 4x6 4x6 4x8 4 X 10 4 X 10 4 X 14
8 4x6 4x8 4x8 4x 10 4 X 10 4 X 14 4 X 14
6x8 6x8 6 X 10 6 X 12
8 4 X 10 4 X 10 4 X 12 4 X 14 4 X 14 4 X 14 4 X 16
6x8 6x8 6 X 10 6 X 10 6 X 10 6 X 12 6 X 12
10 4 X 10 4 X 14 4 X 14 4 X 16 4 X 16 4 X 18 6 X 16 6 X 10 6 X 12 6 X 12 6 X 14 6 X 14 6 X 14
-
@ 4 X 10 4x 14 4x 14 4 X 16 4x 1n 4 X 18 6 X 16 6 X 10 6 X 12 6 X 12 6 x14 (6x½) 6 X 14
B-4 Page 3 of 6 Rev. 03/09
►
B--4
Figure 4/Typical deck elevation looking parallel to rear of dwelling
T
Grealer than 4'-0"
l_
For ledger-11>-house
connection use two
3/80x5" lag bolts at 16" on
cenl8r maximum for joist
spans up 110 22'-0" and 32"
on cenler maximum tor
joists apans up 110 11 '-0".
Distance from edge of 2x6
minimum ledger 110 oenter
of bolt 110 be 11/2 •
minimum.
Figure 5/Typical pad footing
8" to natural grade from tq> of
footing for isolated pier footings
Simpson CB or
equivalent
Figure 6/Typical deck elevation facing rear of dwelling
Decking
Girder
T If greater than
4'-0" provide
braces al
post-to-beam
oonneclions
i
~ 3'--0" maximum ~
Page 4 of 6
42"
minimum
Use two 1/2"0x5" bolts
through 2x6 joists
minimum at 3'-0"
maximum on center.
Distance from edge of
member 110 center of boll
to be 1112• minimum.
Rev. 03/09
8-4
Typical deck
Min. 18 ga. U-lype hangfJI'
Post-to-girder connection
ea .. 1/End condition
Post cap instaled per
manufacaxer's installation
instructions ~2•;:num~
~=::;;;
Provide 4x4 kr.ebraceor
top-to-bottom
brace on the inlllrior side of
all post-lO-beam connections
when post
height exceeds 4•-0·
eau 2/lmerior condition
Post cap installed per
manufacbJrer's
installation
instructions
1s· minim1.m~
Two 1/2 "0 lag ~--'---bolts top and __ _,__~_,.
bonom typical
Page 5 of 6 Rev. 03/09
•
B-4
Coastal Zone Boundary
Legend
D \Mthin Coastal Boundary
D Outside Coastal Boundary
Costar Commision
7575 Metropolitan Drive
Suite 103
San Diego, CA 92108-4402
(619) 767-2370
Page 6 of 6 Rev. 03/09