HomeMy WebLinkAbout2631 ACUNA CT; ; CB044123; Permit10-03-2006 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No. CB044123 Building Inspection Request Line (760) 602-2725 2631 ACUNA CT CBAD RESDNTL Sub Type: 2154911100 Lot#: $31,710.00 Construction Type: Reference #: 0 Structure Type: 0 Bathrooms: MONTOYA RES 135 SF REMOD, RAD 0 NEW Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Orig PC#: ISSUED 11/10/2004 SB 04/11/2005 03/23/2005 TP 201 SF DECK, BATH/LAUNDRY,RE-STUCCO,NEW WINDOWS,60SQS Plan Check#: Applicant: VAN HEFLIN GENERAL CONTRACTOR 2932AVENIDAVALERA 92009 644-3259 Owner: MONTOYA GREGORY L TR&MONTOYA ROSE M TR 2631 ACUNA CT CARLSBAD CA 92009 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee $254.11 Meter Size $0.00 Add'l Reel. Water Con. Fee $165.17 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $3.17 PFF (3105540) $0.00 PFF (4305540) $0.00 License Tax (3104193) $0.00 License Tax (4304193) $0.00 Traffic Impact Fee (3105541) $0.00 Traffic Impact Fee (4305541) $0.00 Sidewalk Fee $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Housing Impact Fee ?? Housing InLieu Fee $0.00 Housing Credit Fee Master Drainage Fee $0.00 Sewer Fee $0.00 Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $69.00 $20.00 $24.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $535.45 Total Fees:$535.45 Total Payments To Date:$535.45 Balance Due:$0.00 BUDDING PI - ATTACHED Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as lees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. . You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to ibis, or as to which the statute of limitations has previously otherwise expired. CITY OF Cfc&rSBAB BUItDINCS'Df PARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE.ONLY PLAN CHECK EST. VAL. Plan Ck. Deposit Validated By '^i>^> Da&12 Address {include Bldg/Suite #}Business Name (at this address) Legal Description Lot No.Subdivision Name/Number Unit No. Phase No. Total # of units Assessor's Parcel #Existing Use Proposed Use Descriptioniption of Work ~d ^ *T-T SQ. FT.fa/W/f74L J&Wffi.'A'.gggiiiiismiNHKyraitf^^ £y77££/6& -MA #of Stories # of Bedrooms # of Bathrooms Name Address City State/Zip Telephone # S!'""1"4'"'5*""""' Fax # Name Address City State/Zip Telephone # Name Address City State/Zip Telephone # (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violatipn of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of notynore than five hundred dollars I$500l). Name State License # _ H/MM Address License Class 77J7 ^gaMflg ^/f City State/Zip .City Business License phoneif Designer Name State License # Address City State/Zip Telephone Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. (~l I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) Jg CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as 'to become subject to Jb>AVorkers' Compensation Laws of California. WARNING: Failure to secure woAers.' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($10(M)00), Irf iraainDri'tMrie cost of compensation, damages as provided for In Section 3706 of the Labor code, Jnterest and attorney's fees. SIGNATURE 1/&M rt-kfavJ DATE MION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). Q 1 am exempt under Section Business and Professions Code for this reason: 1. I personalty plan to provide the major labor and materials for construction of the proposed property improvement. Q YES QNO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): PROPERTY OWNER SIGNATURE DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? n YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? fj YES Q NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit wwuaU LJy'TIfe building (official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within/80 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenoed for a pdrfed PMBQ days (Section 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE Ufa r]J£t**SDATE WHITE: File YELLOW: Applicant PINK: Finance March 13, 2006 City of Carlsbad RE: Building Permit No. CB044123 2631 Acuna Court Carlsbad, California 92009 To Whom It May Concern: I am requesting an extension of the above named permit. There have been numerous cosmetic changes that have lengthened the construction time. I will be requesting a final in approximately one week. Regards, Van Heflin - Contractor (760) 644-2359 City Of Carlsbad SUPPLEMENTAL BUILDING PERMIT APPLICATION FOR REROOFING 1. JOB ADDRESS: 2. TYPE OF BUILDING: RESIDENTIAL t COMMERCIAL 3. ROOF SLOPE: RISE 6 inches in 12 inches 4. NUMBER OF EXISTING ROOF COVERING (circle one) (?) 2 5. TYPE OF EXISTING ROOF COVERING^M^LSHEATHING *6. NEW ROOF MATERIAL 77l£ CLASS A WEIGHT PER SQUARE 7. "NUMBER OF SQUARES 8. TRADE NAME _____ MANUFACTURER 9. ROOF SYSTEM LISTING UL No. _ICBO No. 10. IS THE EXISTING STRUCTURAL DESIGN SUFFICIENT TO SUSTAIN THE WEIGHT OF THE PROPOSED ROOF? YES All roof coverings are required to be CLASS A. Combustible roof coverings of any type or classification are prohibited. I understand the following inspections are required: --, 1. Tear Off/Pre-inspection prior to install new roof covering. 2. Final Inspection I agree to provide a ladder extending at least 2 rungs above the roof for inspection. Signature » - Date Contractor * pwner Contractor Name *6 - Rolled Roofing, Standard/Lite Tile, Asphalt/Comp Fiberglass, Built up, Other. Inspection List Permit*: CB044123 Type: RESDNTL RAD Date Inspection Item 09/28/2006 89 09/22/2006 89 09/22/2006 89 09/14/2005 17 09/01/2005 17 08/26/2005 16 08/16/2005 14 08/16/2005 24 08/16/2005 34 08/09/2005 18 07/11/2005 14 07/11/2005 14 07/11/2005 24 07/11/2005 34 07/11/200544 07/07/2005 14 06/01/2005 14 04/18/2005 15 04/12/2005 21 Inspector Act Final Combo TP Fl Final Combo TP CA Final Combo - Rl Interior Lath/Drywall BN AP Interior Lath/Drywall PC CO Insulation TP AP Frame/Steel/Bolting/Weldin TP AP Rough/Topout TP AP Rough Electric TP AP Exterior Lath/Drywall TP AP Frame/Steel/Bolting/Weld in TP NR Frame/Steel/Bolting/Weldin TP AP Rough/Topout TP WC Rough Electric TP AP Rough/Ducts/Dampers TP WC Frame/Steel/Bolting/Weldin TP NR Frame/Steel/Bolting/Weldin TP NR Roof/Reroof TP AP Underground/Under Floor TP AP MONTOYA RES 135 SF REMOD, 201 SF DECK, BATH/LAUNDRY.RE-STUC Comments SHOWER LATH ONLY INT. BATH OK GARAGE SIDE NOT COMPLETE BATH EXTN. BATH EXTN. BATH EXTN, RE-SCHD7/11 BALCONY & EXPANDED DORMER OVER ENTRY BALCONY & EXPANDED DORMER OVER ENTRY RE-SCHD 7-11. BALC. COVERED W/OUT INSP NEED FLR PNL. REV. @ R. RM. Tuesday, October 03, 2006 Page 1 of 1 \ EsGil Corporation In Partnership with government for (Bui&finff Safety DATE: March 2, 2005 JURISDICTION: Carlsbad PLAN CHECK NO.: 04-4123 SET: III PROJECT ADDRESS: 2631 Acuna Court PROJECT NAME: Montoya SFD Addition/Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. X] The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person X] REMARKS: Plans shall be signed by the person responsible for their preparation. Enclosures: H PC LOG tmsmtl.dot By: Sergio Azuela Esgil Corporation D GA D MB D EJ 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560-1576 EsGil Corporation In Partnership witn government f or (Buififing Safety DATE: February 9, 2005 QAPPLICANT JURISDICTION: Carlsbad Q PLAN REVIEWER Q FILE PLAN CHECK NO.: 04-4123 SET: II PROJECT ADDRESS: 2631 Acuna Court PROJECT NAME: Montoya Addition/ Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Van Heflin 2932 Avenida Valera Carlsbad CA 92009 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Van Heflin Telephone #: 760 644 3259 Date contacted-^? W^by>/^ ) Fax #: 760-930-1390 Mail ^Telephone y Fax •'In Person REMARKS: By: Sergio Azuela for BZ Enclosures: Esgil Corporation D GA D MB D EJ D PC 2/1 tmsmtUot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 Carlsbad 04-4123 February 9, 2005 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: 04-4123 PROJECT ADDRESS: 2631 Acuna Court SET: II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED: ESGIL CORPORATION: 2/1 February 9, 2005 REVIEWED BY: Sergio Azuela FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. B. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. C. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? QYes QNo Carlsbad 04-4123 February 9, 2OO5 1. Please make all corrections on the original tracings, as requested in the correction list. Submit two sets of plans for residential projects. For expeditious processing, corrected sets can be submitted in one of two ways: a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, and (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. The person responsible for their preparation must sign all final sheets of plans. (California Business and Professions Code). 3. Final plans, specifications and calculations shall be signed and sealed by the engineer or architect licensed by the State of California who is responsible for their preparation. Specify expiration date of license. (California Business and Professions Code). 5. Show all repairs from structural calculations on plans. • Provide all applicable framing details and cross-reference details to roof framing plan. • Clearly show the roof sheathing nail size and spacing. Indicate required blocking, instead of only reference the structural design calculations. See sheet A-3. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. EsGil Corporation In <Partnersfiip -with government for Quitting Safety DATE: November 23, 2004 OAPPUCANT JURISDICTION: Carlsbad Q PLAN REVIEWER a FILE PLAN CHECK NO.: 04-4123 SET: I PROJECT ADDRESS: 2631 Acuna Court PROJECT NAME: Montoya Addition/Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Van Heflin 2932 Avenida Valera Carlsbad CA 92009 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Van Heflin Telephone #: 760 644 3259 Date contacted: > l/23/f(by:J^t^ ) Fax#:7£<?-<7<3£> - Mail V Telephoned Fax In Person REMARKS: By: Bryan Zuppiger Enclosures: Esgil Corporation D GA D MB D EJ D PC 11/12/04 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 Carlsbad 04-4123 November 23, 2O04 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 04-4123 JURISDICTION: Carlsbad PROJECT ADDRESS: 2631 Acuna Court FLOOR AREA: See Below STORIES: 2 Dwelling remodel 135 fta Deck addition 2O1 fta HEIGHT: n/a occurs within existing Window replacement and roof repair DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION: ESGIL CORPORATION: 11/12/04 DATE INITIAL PLAN REVIEW PLAN REVIEWER: Bryan Zuppiger COMPLETED: November 23, 2004 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24), which adopts the following model codes: 1997 UBC, 2000 UPC, 2000 UMC and 1999 NEC (all effective 11/1/02). The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy! where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad 04-4123 November 23, 2004 • PLANS 1. Please make all corrections on the original tracings, as requested in the correction list. Submit two sets of plans for residential projects. For expeditious processing, corrected sets can be submitted in one of two ways: a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, and (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. The person responsible for their preparation must sign all final sheets of plans. (California Business and Professions Code). 3. Final plans, specifications and calculations shall be signed and sealed by the engineer or architect licensed by the State of California who is responsible for their preparation. Specify expiration date of license. (California Business and Professions Code). 4. Please use all structural details or omit from plans. 5. Show all repairs from structural calculations on plans. 6. Unable to locate the pole footing from the design calculations on the plans. • FIRE PROTECTION 7. When the valuation of a room addition or repair exceeds $1,000 show locations of permanently wired smoke detectors with battery backup in the new and existing construction, except that smoke detectors added at existing construction need only be battery powered. Section 310.9.1.2: a) Inside each bedroom. b) Centrally located in corridor or area giving access to sleeping rooms. c) On each story. d) In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway. NOTE: Detectors shall sound an alarm audible in all sleeping areas of the unit. Section 310.9.1. Carlsbad 04-4123 November 23, 2004 • GENERAL RESIDENTIAL REQUIREMENTS 8. Glazing in the following locations should be of safety glazing material in accordance with UBC Section 2406.4 (see exceptions): a) Walls enclosing stairway landings or within 5 feet of the bottom and top of stairways where the bottom edge of the glass is less than 60 inches above a walking surface. • ROOFING 9. Specify on the plans the following information for the roof materials, per Section 106.3.3: a) Manufacturer's name. b) Material weight. c) Product name/number. d) ICBO approval number, or equal. • GARAGE AND CARPORTS 10. Garage requires one-hour fire protection on the garage side of walls and ceiling common to the dwelling. Table 3-B, Section 302.4. • ELECTRICAL (NATIONAL ELECTRICAL CODE) 11. Show on the plans that receptacle outlet locations will comply with NEC Art. 210-52(a) at the Landry room. 12. Per NEC Art. 210-11(c)3, note on the plans that bathroom circuiting shall be either: a) A 20 ampere circuit dedicated to each bathroom, or b) At least one 20 ampere circuit supplying only bathroom receptacle outlets. 13. Show on the plans a wall receptacle adjacent to each lavatory in the bathroom. NEC Art. 210-52(d). This receptacle must be GFCI protected. 14. Show at least one wall switch-controlled lighting outlet to be installed in every room and in bathroom of the remodel. NEC Art. 210(a). To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bryan Zuppiger at Esgil Corporation. Thank you. Carlsbad O4-4123 November 23, 20O4 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 04-4123 PREPARED BY: Bryan Zuppiger DATE: November 23, 20O4 BUILDING ADDRESS: 2631 Acuna Court BUILDING OCCUPANCY: R3/U TYPE OF CONSTRUCTION: VN BUILDING PORTION dwelling remodel deck addition Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) 135 201 cb Valuation Multiplier City Valuation By Ordinance Reg. Mod. VALUE ($) 31,710 31,710 $254.11 Plan Check Fee by Ordinance Type of Review: Repetitive FeeRepeats Complete Review D Other i—i Hourly Structural Only Hour* Esgil Plan Review Fee $165.17 $142.30 Comments: macvalue.doc City of Carlsbad Public Works - Engineering DATE: 12 BUILDING PLANCHECK CHECKLIST PLANCHECK NO.: CB BUILDING ADDRESS: PROJECT DESCRIPTION: ASSESSOR'S PARCEL NUMBER:~ t EST. VALUE: ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submitted; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. D A Right-of-Way permit is required prior to construction of the following improvements: DENIAL Please sg^Trw attached report of deficiencies marked/with D/Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: By: Date: Date: By: FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: Date: ATTACHMENTS D Dedication Application 0 Dedication Checklist D Improvement Application D Improvement Checklist D Future Improvement Agreement D Grading Permit Application LJ Grading Submittal Checklist LJ Right-of-Way Permit Application [] Right-of-Way Permit Submittal Checklist and Information Sheet r~iLJ Sewer Fee Information Sheet Name: ENGINEERING DEPT. CONTACT PERSON Linda Ontiveros City of Carlsbad Address: 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: (760) 602-2790 CFD INFORMATION Parcel Map No: Recordation: Carlsbad Tract: , CA 9200^-7314 • (760) 602-2720 • FAX (760) 602*8562 BUILDING PLANCHECK CHECKLIST SITE PLAN ully dimensioned site plan drawn to scale. Show: rt-St Existing-Sr-Proposed Structures sting Street Improvements Property Lines f&rt Easements rn vAA_\ LP'TRight-of-Way Width SrAdjs ^Qr Driveway widths H. Existing or proposed sewer lateral I. Existing or proposed water service J- Existing or proposed irrigation service n 2. Show on site plan: rainage Patterns ^—n. Building pad surface drainage must maMain'a minimum ^locte of f ne percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography C. Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. D. Sewer and water laterals should not be located within proposed driveways, per standards. 3. Include on title sheet: iddress IjjjAssessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION FAENG TECH COUNTERBUILDING PLANCHECK CKLST FOHM.doe BUILDING PLANCHECK CHECKLIST RO3 D DISCRETIONARY APPROVAL COMPLIANCE 4a. Project does not comply with the following Engineering Conditions of approval for Project No. D 4b. All conditions are in compliance. Date: DEDICATION REQUIREMENTS 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $_15,000 pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 81/2" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by:Date: IMPROVEMENT REQUIREMENTS 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $_75.0QO pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the F:\ENG TECH COUNTEF*BUILDIN6 PLANCHECK CKLST FORM.doc ..ST pND QRD BUILDING PLANCHECK CHECKLIST checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: Date: D D D 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $310 so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: D D D 6c. Enclosed please find your Neighborhood Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. i Neighborhood improvement Agreement completed by: Date: G 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. CD D 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). D D D 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: D D D 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) F:\ENQ TECH COUNTER\BUILDING PLANCHECK CKLST FORM.doc BUILDING PLANCHECK CHECKLIST iST 7d .No Grading Permit required. 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153, for assistance. Industrial Waste permit accepted by: Date: D 10. NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. D 11- Q^Kequired fees are attached Q No fees required WATER METER REVIEW O 12a. Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. • All single family dwelling units received "standard" 1" service with 5/8" service. P\ENG TECH COLJNTER\BU1LD)NG PLANCHECK CKLST FORM.doo BUILDING PLANCHECK CHECKLIST iST D D D • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). A typical fixture count and water demand worksheet is attached. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. • Maximum service and meter size is a 2" service with a 2" meter. • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand, (manifolds are considered on case by case basis to limit multiple trenching into the street). 12b. Irrigation Use (where recycled water is not available) AH irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: 1. If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service should look like: . STA1+00 Install 2" service and 2. 3. 1.5: meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water F:\ENG TECH COUNTE REBUILDING PLANCHECK CKLST FOHM.doc BUILDING PLANCHECK CHECKLIST .. ST service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future. LZI D 12c. Irrigation Use (where recycled water is available) 1. Recycled water meters are sized the same as the irrigation meter above. 2. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this. D D D 13. Additional Comments: F:\ENO TECH COUNTERlBUlLDING PLANCHECK CKLST FORM.doe PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB ADDRESS DATE ll-It- RESIDENTIAL ADDITION MINOR « $10,000.00) TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER DATE //' Hi ENGINEER DATE NOTES: Montoya Residence, 2631 AcunaCt., Carlsbad, CA 92009 w/Hamid Site visit on Tuesday, June 29, 2004 Up in the attic. The main things that we found were we've got...the main framing is 2x6*s - I think we measured them and horizontally the span is 14'. There is a purlin that's 5* down from the ridge. The rafters are 2x6 @ 16. We have a 2x8 every once in a while - I'm not quite sure what that's all about. The ridge is a 2x10. The hips are 2xlO's as well. Purlins are 2x10. There's kickers on the purlins every 6'-8', other than on the....The front of the house faces north. On the south side of the house, the purlin is just totally butchered. There are vent pipes going through it where they've notched it. The plumber and the mechanical guy, if they're one and the same, you only have to shoot one person, but if they were 2 different people, they both need to be shot. They've notched out the purlin, and then there was a splice in the purlin where there were 2 joints - 2 kickers carrying the purlin. He put the furnace right there and got rid of both kickers, so there is no support at a splice in the purlin. So, in essence, the purlins are doing nothing. They're not reducing the span of the 2x6's at all. The 2x6's are spanning roughly 14'- 15" horizontally. The purlin is definitely deflected and it needs to be repaired. The concept here is to come in and re-support the purlins, splice another one right up alongside of it, and attach it to the existing kickers, and then come in along all the purlins and provide additional kickers about halfway between the ones that are there. Calculate the joists. Make sure the 2x6's can span roughly 9' horizontally, which is 14', 13' on the slope. At either end we've got hips that go all the way down in the back. We've got hips that come partially down and then they attach to a ridge that creates the dormers at each end. The ridge is supported at each end. We want to put an additional support under the ridge, about mid-span where the upper hip and the lower hip for the dormer tie to it. We've got a picture of it. We want to add that to it. Calculate the rafters to make sure they work. If they do, then we just go along with the purlin supports. We want to modify the collarties. The collarties are only about a 12"-16" overlap and not nailed very well, so with the inadequate vertical, i.e., no beams, but boards, and inadequate collarties, you can't really make either of the systems work, and it's a combination of the two, which is unbelievably indeterminate. The collarties look like they're 2x8's. Project Ref.: 042598-2 Page 1