Loading...
HomeMy WebLinkAbout2632 La Gran Via; ; CBR2019-1944; PermitBuilding Permit Finaled Print Date: 06/24/2020 Job Address: PermitType: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2632 La Gran Via BLDG-Residential 2162503100 $28,560.93 Residential Permit Work Class: Alteration Lot#: Reference#: Construction Type Bathrooms: Orig. Plan Check#: Plan Check#: {cityof Carlsbad Permit No: CBR2019-1944 Status: Closed -Fina led Applied: 07/24/2019 Issued: 10/01/2019 PermitFinal Close Out: Inspector: LStor Final Inspection: 06/24/2020 Description: SMITH: 487 SF REMODEL TO KITCHEN/DINING AND BATH // RE-ROOF 31 SQUARES CONCRETE TO COMP SHINGLE Owner: COOWNER MIKE & DIANA SMITH 2632 La Costa Ave FEE BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) CARLSBAD, CA 92009 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL 581473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $570.43 Total Payments To Date: $570.43 Balance Due: AMOUNT $271.60 $190.12 $41.00 $62.00 $2.00 $3.71 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Buildin Division 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov Page 1 of 1 (City of Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 JobAddress 21..3.2.. L4 G,~AN V(A Suite: N fA CT/Project#: _________ Lot#: 453 Plan Check c9R-v-1~g Est. Value / S'~(),Cf.:3 PC Deposit --------- Date ____.]_,_/J><=-4_,__,_,_f/_._'.3_ I 1 APN: .;}_/4,-.2_'50 -3/ -00 BRIEF DESCRIPTION OF WORK: =..=:..:....,:=-:..!..!..!,"'-''-'-'=IL""-"='-"i--':s:..k"-'-'i s._/'-''C!.j'~--'/_,..1,4"". J..,,+:i.--"~"'-"'.U'(j"-. hu:-1-...c ___ _ co cr~k. s U □ Addition/New: _____ Living SF, ____ Deck SF, ___ Patio SF, ___ Garage SF Is this to create an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __ ~ Remodel: 4 9 f: SF of affected area Is the area a conversion or change of use ? Yes .G) D Pool/Spa: ____ SF Additional Gas or Electrical Features? ___________ _ □ Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground , Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No Panel Upgrade: Yes/ No D Reroof: ___________________________________ _ □ his Q.('(a mma,·"" in O(.i oc<:i. 1b11s. APPLICANT (PRIMARY CONTACT) PROPERTY ?WNER 1 Name: M11t..1: ~ DIANA S"tvl 17 +/ Name: (_SAM-f AS A-PPL I 4A NT} Address: 2t,3,J,, /...A Es,/lAN v,4 Address: ____________ -__ _ City: CAII..LS84/) State: CA Zip: "'Jl-ooCj City: ________ .State:_......cZip: ---- Phone: 1:C.D -4Df: -':fQf; ~ Phone: Email: cJ... io IIQ,a, S f'Y1 i-fl, @j /'Y)().j /. cam Email: ________________ _ IS&o DESIGN P,Rf>FESSIONAL " CONTRACTOR BUS~ES~ • Name: !Lt! L.<..E7TA !,!.t.S/GtN & RQ u.,O N,me: --'-N_,/4"'"~..:......,6..:st:...,..,., .... (.,_I -"' n'-'-'b"-1'-="d"-'d='ll<l ........ ~P=m=-cc==s=s=-+) ess: 3 3 D N. GDAST HltfY (0/ J S • ltiaress: _________ _cJ:,::__ ____ ./_ City: €NC{N(TAJ State: CA Zip: '1,0),{ City: _______ State: __ .Zip: _____ _ Phone: ::,..C,,0-{/f?J -55'1 l Phone: ______________ _ Email: , qur<tJ@ valf~Ha. cfes 13aJ .-oup. wrnEmail: --------------- Architect State License: ___________ State License: ______ Bus. License: _____ _ (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's license law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-1 Page 1 of 2 Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: □ I have and will maintain a certificate of consent to self•insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. □ I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: ______________________ _ Policy No. ______________ Expiration Date: _________ _ □ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, Interest and attorney's fees. CONTRACTOR SIGNATURE: □AGENT DATE: ------------------------------ ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). wf I, as owner of the property, am exclusively contracting with licensed contractors to construct the project {Sec. 7044, Business and Professions Code: The ~ntractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's license Law). 0 I am exempt under Section ________ Business and Professions Code for this reason: 1. I personalty plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work): OWNER SIGNATURE: ~~ □AGENT DATE: lo /4 Ir '1 CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: ______________________ Lender's Address: _____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: ls the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D Yes D No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CllY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the pro ·sions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within ays from the date of s p~rm1 or if the bu1ld1ng or work authonzed by such permit 1s suspended or abandoned at any time after the work is commenced for a peri of 1 days (Section 106.4 rnfor Building Code). DATE·. 1 (2,i/ ! / Ci_ APPLICANT SIGNATURE: _ ~ I 1635 Faraday Ave Carlsbad, CA 92008 B-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of2 Email: Building@carlsbadca.gov Rev. 06/18 PERMIT INSPECTION HISTORY for (CBR2019-1944) Permit Type: BLDG-Residential Application Date: 07/24/2019 Owner: COOWNER MIKE & DIANA SMITH Work Class: Alteration Issue Date: 10/01/2019 Subdivision: LA COSTA SOUTH #6 Status; Closed -Finaled Expiration Date: 10/01/2020 Address: 2632 LA GRAN VIA IVR Number: 20575 CARLSBAD, CA 92009-8109 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 02/04/2020 02/04/2020 BLDG-82 Drywall, 118301-2020 Passed Luke Storno Complete Exterior Lath, Gas Test, Hot Mop Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-17 Interior Lath-Drywall No BLDG-18 Exterior Lath and No Drywall BLDG-23 Gas-Test-Repairs No 03/02/2020 03102/2020 BLDG-18 Exterior 121006-2020 Passed Tony Alvarado Complete Lath/Drywall 06/24/2020 0612412020 BLDG-Final Inspection 130925-2020 Passed Chris Renfro Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Wednesday, June 24, 2020 Page 2 of 2 Building Permit Inspection History Finaled ( City of Carlsbad PERMIT INSPECTION HISTORY for (CBR2019-1944) Permit Type: BLDG-Residential Application Date: 0712412019 Owner: COOWNER MIKE & DIANA SMITH Work Class: Alteration Issue Date: 10/01/2019 Subdivision: LA COSTA SOUTH #6 Status: Closed -Finaled Expiration Date: 10/01/2020 Address: 2632 LA GRAN VIA IVR Number: 20575 CARLSBAD, CA 92009-8109 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 11101/2019 11/01/2019 BLDG-81 Underground 109566-2019 Passed Luke Storno Complete Combo(11, 12,21,31) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-11 Foundation-Ftg-Piers No (Rebar) BLDG-12 Steel-Bond Beam No BLDG-21 No Underground-Underiloor Plumbing BLDG-31 No Underground-Conduit VViring 11/06/2019 11/06/2019 BLDG-11 110036-2019 Passed Chris Renfro Complete Foundatlon/Ftg/Plers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency (4) pier footings. Ok to pour Yes 11126/2019 11/26/2019 BLDG-15 Roof/ReRoof 112221-2019 Passed Paul Burnette Complete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 01/08/2020 01/08/2020 BLDG-13 Shear 115697-2020 Passed Luke Storno Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Ext. shear No 01/23/2020 01/2312020 BLDG-18 Exterior 117292-2020 Passed Luke Storno Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-84 Rough 117291-2020 Passed Luke Storno Complete Combo(14,24,34,44) Wednesday, June 24, 2020 Page 1 of 2 {"city of Carlsbad SPECIAL INSPECTION AGREEMENT B-45 Development Services Building Division SEP O 6 2019 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed requires special inspection, structural observation and construction material testing. Project/Permit: C,(j(<.JQ/~-/qL/3/ ProjectAddress· .2(,,32. LA 6fJ.AN V,A A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder □. (If you checked as owner-builder you must also complete Section B of this agreement.) Name: (Please print) D, AN A A s /11. er ti Mailing Address· 2c,3 2 (F"'' 1 t.A 6.l.AI\J 11,'.a:. ~~LS!;,4£) CA 9J...oo9 Email· di O.nq, a. S'l'Yl i-1+t@r41' (. CD~ Phone: i-c.o-40~ -::/-()51.,. I am: ~roperty Owner □Property Owner's Agent of Record □Architect of Record □Engineer of Record State of California Registration Numbe · Expiration Date: ________ _ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, struction materi testing and off-site fabrication of building components, as prescribed in the statement of special insp lion note9 on the a prov p ns and, as required by the California Buildi7g CJde. Signatur · Date: 'l / 4 ,_2o I 1 B. CONTRACTOR'S STAT?;;N~OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor/ builder /'6wRe_c_uild~ Contractor's Company Name: ___________________ Please check if you are Owner-Builder D Name: (Pleaseprint) __ __,_yv)__,_,-=C'-'-tJ,'-'ftEJ.-=c·L-c=--------A--'---------.::c_$.:..1'l._,_.n-J,-_,_ _____ _ (First) Mailing Address: 54/'A-~ (MJ.) (Last) Email: J,a.llA ,4 . .51\A•'1➔@JM£<, \, c~./v\. Phone:__.:..7.=(,_D_-_l..f-'DS'--/ 7_D_5_,b'"'-~- State of California Contractor's License Number:. __________ Expiration Date: _______ _ • I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; • I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; • I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and • I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. • I will provide a final report I letter in compliance with CBC Section 1704.1.2 prior to requesting final Signatu::spection. ~L Date: 'T / h /, J /! 8-45 Page 1 of 1 Rev. 08/11 B-10 REROOFING SUPPLEMENTAL BUILDING PERMIT APPLICATION 1. JOBADDREss: 2&,32, LA. (;JR.AN VtA, CAR.Ls&Aq G4 9:2001 2. TYPE OF BUILDING: RESIDENTIAL __ X~--COMMERCIAL. ___ _ 3. ROOF SLOPE: RISE 't INCHES IN 12 INCHES 4. NUMBER OF EXISTING ROOF COVERING (CIRCLE ONE) G) 2 3 5. TYPE OF EXISTING ROOF COVERING Ci> we~ t.7£ SHEATHINGS f:.1 p *6. NEW ROOF MATERIAL A~Pt/AL-T CLAss_A_wEIGHT PER so.JOO-~!D lhs. 7. NUMBER OF SQUARES 3/ {OfpCDx,mAk J s. TRADE NAME..,..jljl,1~ _____ MANuFAcTuRER QwbN"s Cot.NtN6J.. 9. ROOF SYSTEM LISTING: UL NO. f P-2'-lf;-3-6/1.c.c.E.S. Report# AC L/-3& ASTM J) 2,-:i..g 10.IS THE EXISTING STR~ DESIGN SUFFICIENT TO SUSTAIN THE WEIGHT OF THE PROPOSED ROOF? ~ NO All roof coverings are required to be CLASS A. Combustible roof coverings of any type or classification are prohibited. I understand the following inspections are required: 1. Tear Off/Pre-Inspection prior to install new roof covering 2. Final Inspection I agree to pro · a ladder exte ding at least 2 rungs above the roof for inspection. Signature _____ ~ ________ Date 1/ut/1 °1 Contractor Owner )( Contractor --------- Name ----------- *6. Rolled Roofing, Standard/Lite Tile, Asphalt/Comp fiberglass, Built Up, Other Page 6 of 6 Rev. 04/14 DATE: September 18, 2019 JURISDICTION: Carlsbad ✓• EsG1I A SAFEbu1lt Company PLAN CHECK#.: CBR2019-1944 PROJECT ADDRESS: 2632 La Gran Via SET: II PROJECT NAME: Interior Remodel for Smith Residence ~ APPLICANT L -JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. C8J The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: C8J EsGil staff did not advise the applicant that the plan check has been completed. C8J EsGil staff did advise the applicant that the plan check has been completed. Person contacted: / ti.A Telephone#: Date contacted: (by: ;fl'~ Email: Mail Telephone Fax In Person j REMARKS: Havetl1e-a1919lieaF1! i,rooide tf'le City's 819ceiariF1si,eetior, Fofffi. Interior Designer needs to sign the sheets they ~~epared . ......__,_ clu..cla.J a-J:- \)Y' ~ ov->yu.,V' By: ~:~~f Kniff Enclosures:~ /?-5/14. 9/10/2019 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 DATE: August 1, 2019 JURISDICTION: Carlsbad ✓• EsG1I A SAFEbuilt Company PLAN CHECK#.: CBR2019-1944 PROJECT ADDRESS: 2632 La Gran Via SET: I PROJECT NAME: Interior Remodel for Smith Residence D APPLICANT D JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Mike & Diana Smith D EsGil staff did not advise the applicant that the plan check has been completed. ~ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Diana Telephone#: 760-405-7056 Date contacted: (by: ) Email: diana.a.smith@gmail.com Mail Telephone Fax In Person 0 REMARKS: By: Kat Frankowski EsGil Enclosures: 7/25/2019 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBR2019-1944 August 1, 2019 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CBR2019-1944 PROJECT ADDRESS: 2632 La Gran Via FLOOR AREA: Remodel = 497 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: Auirust 1, 2019 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad STORIES: HEIGHT: DATE PLANS RECEIVED BY ESGIL CORPORATION: 7/25/2019 PLAN REVIEWER: Kat Frankowski This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBR2019-1944 August 1, 2019 PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Please update scope to include new roof. 4. Dimension the window in the kitchen. 5. Before submitting final set of plans, please remove "not for construction" from them. 6. Please complete the Carlsbad special inspection form. FIRE PROTECTION 7. Show locations of permanently wired smoke alarms with battery backup, per Section R314: a) Inside each bedroom. b) Outside each separate sleeping area in the immediate vicinity of the bedrooms. c) On each story, including basements. d) Such smoke alarm locations shall comply with the following: i) They shall be not less than 3' from the door opening of a bathroom. ii) They shall be at least 20' from a cooking appliance. iii) They shall be at least 3' from supply registers of heating/cooling systems. iv) They shall be at least 3' from the tip of the blade of a ceiling-mounted fan. • NOTE: When more than one smoke alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the unit. Carlsbad CBR2019-1944 August 1, 2019 8. In existing buildings, when alterations, repairs or additions requiring a permit occur (or when one or more sleeping rooms are added), the dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarms shall be interconnected and hard wired. Exception: Smoke alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R314.8.1. 9. In dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), show the locations of permanently wired carbon monoxide alarms with battery backup, per Section R315: a) Outside each separate sleeping area in the immediate vicinity of the bedrooms. b) On each story, including basements. • NOTE: When more than one carbon monoxide alarm is required to be installed, the alarm devices shall be interconnected in such a manner that the actuation of one alarm will activate all of the alarms in the unit. 10. When alterations, repairs or additions are proposed for dwelling units within which fuel- burning appliances are installed (and in dwelling units having attached garages), the dwelling unit shall be provided with carbon monoxide alarms located as required for new dwellings; the carbon monoxide alarms shall be interconnected and hard wired. Exception: Carbon monoxide alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R315.2. GENERAL RESIDENTIAL REQUIREMENTS 11. Glazing in the following locations should be shown on the plans as safety glazing material in accordance with Section R308.4: a) Glazing in doors. 12. Show landings at exterior doors. There shall be a landing or floor on each side of each exterior door. The width of each landing shall not be less than the door served and have a minimum or 36-inches measured in the direction of travel. Exterior landings shall be permitted to have a slope not to exceed ¼-inch per foot. Landings or finished floors shall not be more than 1.5 inches lower than the top of the threshold for outward swinging exterior doors or 7.75" for doors that do not swing outwards. R311.3. ROOFS/DECKS/BALCONIES Carlsbad CBR2019-1944 August 1, 2019 13. Enclosed rafter spaces do not require venting if the following specific insulation design is used, per Sections R806.5/EM3.9.6: ♦ If the insulation is air-permeable and it is installed directly below the roof sheathing with rigid board or sheet insulation with a minimum R-4 value installed above the roof sheathing. (or) ♦ If the insulation is air-impermeable and it is in direct contact with the underside of the roof sheathing. (or) ♦ If two layers of insulation are installed below the roof sheathing: An air-impermeable layer in direct contact with the underside of the roof sheathing and an additional layer of air permeable insulation installed directly under the air-impermeable insulation. Show how one of the above conditions is met. Provide a detail. STRUCTURAL 14. Show rafter ties. Section R802.3.1. 15. Indicate spacing for the cripple wall framing. ELECTRICAL 16. Note on the plans that receptacle outlet locations will comply with CEC Article 210.52. 17. Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all receptacles in a dwelling). b) Weather resistant type for receptacles installed in damp or wet locations (outside). c) Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.12(A): Kitchens, laundry areas, family, living, bedrooms, dining, halls, etc. d) GFCI protected outlets for locations described in NEC 210.8(A): Laundry areas, kitchen dishwashers, kitchens, garages, bathrooms, outdoors, within 6' of a sink, etc. 18. A balcony, deck, or porch that is accessible from the interior of the dwelling will require a minimum of one receptacle outlet. CEC 210.52(E) (3). This receptacle must be GFCI protected. 19. Show on the plans a wall receptacle within 36" of each lavatory in the bathroom. CEC 210.52(0). Show at second lavatory. PLUMBING 20. Dimension on the plans the 30" clear width required for the water closet compartment and the (minimum) 24" clearance required in front of the water closet. CPC 402.5. Carlsbad CBR2019-1944 August 1, 2019 21. Provide a note on the plans: The control valves in showers, tub/showers, bathtubs, and bidets must be pressure balanced or thermostatic mixing valves. CPC Sections 408, 409,410. 22. Specify on the plans: Water conserving fixtures: New water closets shall use no more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8 GPM, lavatories are limited to 1.2 GPM, and showerheads may not exceed 1.8 GPM of flow. CPC Sections 407,408,411, 412. 23. Specify on the plans whether the existing house was built before or after 1994. For additions or improvements to a residence built before 1994, note on the plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons of water per flush, urinals that use more than one gallon of water per flush, showerheads that have a flow capacity of more than 2.5 gallons of water per minute, and interior faucets that emit more than 2.2 gallons of water per minute) shall be replaced. Certification of compliance shall be given to the building inspector prior to final permit approval. California SB407. ENERGY CONSERVATION Residential Energy Lighting Requirements: ES 150.0(k) 24. All installed luminaires shall be high-efficacy in accordance with ES TABLE 150.0-A. Light sources that are not marked "JA8-2016-E" shall not be installed in enclosed luminaires. ES 150.0(k) 25. In bathrooms, garages, laundry rooms, and utility rooms at least one luminaire shall be controlled by a vacancy sensor. 26. Dimmers or vacancy sensors shall control all LED style luminaires. Two exceptions: Fixtures installed in hallways or (closets under 70 square feet). 27. Recessed can light fixtures shall be iC listed, air-tight labeled, and not be equipped wiih a standard medium base screw shell lamp holder. ES 150.0(k) 28. SFD outdoor lighting fixtures that are attached to a building are required to be high efficacy, be manually on/off switch controlled, and have both motion sensor and photocell control. See ES 150.0(k) 3 for additional control options. Residential ventilation requirements: ES 150.0(o)/ASHRAE 62.2 29. Kitchens require exhaust fans with a minimum 100 cfm ducted to the exterior. Detail compliance by including a complying exhaust fan or a ducted range hood to the exterior. 30. Residential bathroom exhaust fans shall be energy star rated and shall be control by a humidistat capable of an adjustment between 50 and 80% humidity. CalGreen 4.506.1. Exception: Control by a humidistat is not required if the bathroom exhaust fan is also the dwelling whole house ventilation. Alterations Carlsbad CBR2019-1944 August 1, 2019 31. Fenestration alterations must meet all requirements of ES 150.1(c) and Table 150.1-A except: 32. 75 sq. /ft. square feet may be added and not be required to meet the total fenestration or west facing fenestration maximum areas. 33. Replacement of existing fenestration up to 75 sq. /ft. only needs to meet the U-factor of .40 and SHGC of .35 specifications, not the Table 150.1-A specification values. "Replacement" windows are windows replaced in the same wall with the same total fenestration area per wall as the existing. MISCELLANEOUS 34. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 35. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 36. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kat Frankowski at EsGil. Thank you. Carlsbad CBR2019-1944 August 1, 2019 ~~ ~ CITY OF CARLSBAD SPECIAL INSPECTION AGREEMENT B-45 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.sov In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed requires special Inspection, structural observation and construction material testing. >roject/Permit: __________ Project Address;_· ----------------- A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check W you are Owner-Builder □. (If you checked as owner-builder you must also complete Section B of this agreement) Name: (Please print,__ _______________________________ _ (First) (M.1.) (Last) Mailing Addres~--------------------------------- Emai~·------------------------Phone· __________ _ I am: □Property Owner □Property Owner's Agent of Record □Architect of Record □Engineer of Record state of California Registration Numbe~·------------Expiration Date: _______ _ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the state of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspectons, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspections noted on the approved plans and, as required by the California Building Code. Signatur._· ______________________ Date: ___________ _ B. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor I builder/ owner-builder. Contractor's Company Name: __________________ Please check lfyoo are Owner-Builder D Name: (Pleaseprint) ____ ~-c---------=,------------,--,,---------(Flrst) (MI ) (Last) Mailing Address_·---------------------------------- Email: ________________________ Phone· __________ _ state of California Contractor's License Number· __________ Expiration Date: _______ _ • I acknowledge and, am aware, of special requirements contained in the statement of special inspectons noted on the approved plans; • I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; • I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and • I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. • I will provide a final report/ letter In comp/lance with CBC Section 1704.1.2 prior to requesting final Inspection. Signature·~----------------------'Date: __________ _ El-45 Page 1 of 1 Rev. 08/11 Carlsbad CBR2019-1944 August 1, 2019 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Kat Frankowski BUILDING ADDRESS: 2632 La Gran Via BUILDING OCCUPANCY: PLAN CHECK#.: CBR2019-1944 DATE: August 1, 2019 BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Remodel 497 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance 1997 UBC Buildin g Permit Fee ... 1997 UBC Plan Check Fee • Type of Review: 0 Complete Review D Repetitive Fee .., Repeats D Other □ Hourly EsGII Fee Reg. VALUE Mod. D Structural Only ,--------11 Hr. @ * Comments: In addition to the above fee, an additional fee of$ $ /hr.} for the CalGreen review. ($) 28,561 28,561 $176.861 is due ( hour@ Sheet of ( City of Carlsbad PURPOSE CLIMATE ACTION PLAN CONSISTENCY CHECKLIST B-50 Development Services Building Division 1635 Faraday Avenue (760) 602-2719 www.carlsbadca.gov This checklist is intended to assist building permit applicants identify which Climate Action Plan (CAP) ordinance requirements apply to their projects. Unless none of the requirements apply, the completed checklist must be included in the building permit application. It may be necessary to supplement the completed checklist with supporting materials, calculations or certifications, to demonstrate full compliance with CAP ordinance requirements. For example, projects that propose or require a performance approach to comply with energy- related measures will need to attach to this checklist separate calculations and documentation as specified by the ordinances. " If an item in the checklist is deemed to be not applicable to a project, or is less than the minimum required by ordinance, an explanation must be provided to the satisfaction of the Building Official. " Details on CAP ordinance requirements are available on the city's website. Project Name/Building Permit No.: Property Address/APN: Applicant Name/Co.: Applicant Address: Contact Phone: _______ BPNo.: ~R;t.Jfi -l9YY 2-~52.. LA GllAI\I VtA,, CAfli8..4~ CA MrK.G1 DIANA sm,n/ 1'"(.0 -4DG -7-o 5lo Contact Email: '11.ooQ /:;.1&>-J-5/> -3l-oo 7 Contact information of person com leting this checklist (if different than above): Name: Company name/address: B-50 Contact Phone: Contact Email: Applicant Signature:_~~-----------~--Date: _1--+--~....a.+I~-'--/ 9..,__._,_ Page 1 of 3 Revised 04/19 City of Carlsbad Climate Action Plan Consistency Checklist Use the table below to determine which sections of the Ordinance Compliance checklist are applicable to your project. For residential alterations and additions to existing b,¥!l~in9l c~t the building counter for the building permit valuation. Building Permit Valuation (BPV) $ 'is 'J (9U · lA..J Construction Type Complete Section(s) Notes: D Residential D New construction Alterations: D BPV ~ $60,000 D Electrical service panel upgrade 1A 1-2 family dwellings and townhouses with attached garages only D BPV ~ $200,000 1A Multi-family dwellings only where interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed D Nonresidential D New construction 1B and 2 D Alterations 2 1. Electric Vehicle Charging A D Residential New construction and major alterations (or electric panel upgrade)* Please refer to Carlsbad Ordinance CS-349 when completing this section. D One and two-family residential dwelling or townhouse with attached garage: D One EVSE ready parking space required D Exception : D Multi-family residential· D Exception · Total Parking Spaces EVSE Spaces Proposed Capable I Ready I I I Calculations: Total EVSE spaces = .10 x Total parking (rounded up to nearest whole number) EVSE Installed = Total EVSE Spaces x .50 (rounded up to nearest whole number) EVSE other= Total EVSE spaces -EVSE Installed (EVSE other may be "Capable," "Ready" or "Installed.") Installed I Total I *Major alterations are: (1) for one and two-family dwellings and townhouses with attached garages, alterations have a building permit valuation~ $60,000 or include an electrical service panel upgrade; (2) for multifamily dwellings (three units or more without attached garages), alterations have a building permit valuation ~ $200,000, interior finishes are removed and significant site work and upgrades to structural and mechanical, electrical, and/or plumbing systems are proposed. B D Nonresidential new construction (includes hotels/motels) D Exception · Total Parking Spaces EVSE Spaces Proposed Capable I Ready I Installed I Total I I I Calculation: Refer to the table below: Total Number of Parking Spaces provided Number of required EV Spaces Number of required EVSE Installed Spaces □ 0-9 1 1 □ 10-25 2 1 □ 26-50 4 2 □ 51-75 6 3 □ 76-100 9 5 □ 101-150 12 6 □ 151-200 17 9 □ 201 and over 10 percent of total 50 percent of Required EV Spaces Updated 4/ 12/20 I 9 2 City of Carlsbad Climate Action Plan Consistency Checklist 2. 0 Transportation Demand Management (TDM) A. List each proposed nonresidential use and gross floor area (GFA) allocated to each use. B. Employee ADT/1,000 square feet is selected from the table below. Use GFA Employee ADT for first Employee ADT for each 1,000 S.F. subsequent 1,000 S.F. Total If total employee ADT is greater than or equal to 110 employee ADT, a TOM plan is required. TOM plan required: Yes D No D Updated 4/12/2019 Employee ADT Estimation for Various Commercial Uses ADT for first 1,000 s.f. EmpADT/ 1000 s.f.1 Office (all)2 20 Restaurant 11 Retail3 8 Industrial 4 Manufacturing 4 Warehousin 4 1 Unless otherwise noted , rates estimated from /TE Trip Generation Manual, 10th Edition 20 11 4.5 3.5 3 1 2 For all office uses, use SAN DAG rate of 20 ADT/1,000 sf to calculate employee ADT 3 Retail uses include shopping center, variety store, supermarket , gyms, pharmacy, etc. Other commercial uses may be subject to special consideration Sample calculations: Office: 20,450 sf 1. 20,450 sf/ 1000 x 20 = 409 Employee ADT Retail: 9,334 sf 1. First 1,000 sf= 8 ADT 2. 9,334 sf -1,000 sf = 8,334 sf 3. 8,334 sf/ 1,000 x 4.5 + 8 = 46 Em lo ee ADT Total Employee ADT 3