Loading...
HomeMy WebLinkAbout2632 Obelisco Pl; ; 80-176; PermitLICENSED CONTRACTOR'S DECLARATION I hereby alflrm that I am licensed urtder provi sions ol Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Profes sions Code, and my license is in full force and ef fect. OWNER-BUILDER DECLARATION□ 1 hereby affirm that I am exempt from the Contractor's License Law for the following reason(Sec. ^31.5 Business and Professions Code), Anycity or county which requires a permit to con struct. alter. Improve, demolish, or repair any structure, prior to its Issuance also requires the applicant (or such permit to file a signed statement that he Is licensed pursuant to the provi sions of the Contractor's License L^w (Chapter 9commencing with Section 7000 of Division 3 ofthe Business and Professions Code) or that is exempt therefrom and the basis for the alleged ex emption. Any violation of Section 7031.5 by an ap plicant for a permit subjects the applicant to acivil penalty of not more than five hundred dollars ($500). Ci I, as owner of the property, or my employees with wages as their sole compensation, will do the worV, and the structure Is not intended or offered for sale (Sec. 7044, Business and Profes sions Code: The Contractor's License Law doesnot apply to an owner of property who builds orImproves thereon and who does such worKhimself or through his own employees, provided that such Improvements are not Intended or of fered for sale. If, however, the building or improvement Is sold within one year ol completion, theowner-builder will have the burden of proving that he did not build or Improve for the purpose of sale). '□I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and ProfessionsCode: The Contractor's License Law does not ap ply to an owner of property •ho builds or Improves thereon, and who contracts for such projects with a contractor(s) license pursuant to thecontractor's License Law).I am exempt under Sec B. & P.C.for this reason Date Owner WORKERS' COIklPENSATION DECLARATIONI hereby affirm that I have a certificate of con sent to self-insure, or a certificate of Workers'Compensation Insurance, or a certified copy thereof (Sec. 3800, Labor Code), POLICY NO COMPANY □ Copy is tiled with the city.□ Certified copy Is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE(This section need not be completed if the per mit Is for one hundred dollars ($100) or less). I certify that In the performance of the work forwhich Lhls permit is issued. I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. NOTICE TO APPLICANT: If, after making this Certificate of Exemption, you should become subject to the workers' Compensation provisions of the Labor Code, you must forthwith comply with suchprovisions Of this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there Is a construction lending agency for the performance of the work for USE BALL POINT PEN ONLY CITY OF CARLSBAD-BUILDING DEPARTMENT APPLICATION & PERMIT 1200 ELM AVENUE (714) 438-5525 APPLICANT TO FILL IN INFOR MATION WITHIN RED LINES. OWNER OWNER'S MAILING ADORESS ^OWNER'S MAILING ADORUS jaP AV. ST. RD I 'l l !dwNER'S PHONE fip t> ^ LOT BLOCK SUBOIVISION' ASSESSOR'S PARCE:e DATE OF APPLICATION PRIME CONTRACTOR^ A - CONTRACTOR'S ADDRESS DESCRIPTION or WORK l no. I I I I I I I I CENSUS TRACT BLD6 SO. FT. QTY. GP LAND USE PLUMBING PERMIT EACH FIXTURE TRAP EACH BUILDING SEWER EACH WATER HEATER AND/OR VENT EACH GAS SYSTEM 1 TO 4 OUTLETS EACH GAS SYSTEMS OR MORE EACH INSTAL., ALTER. REPAIR WATER PIPE EACH LAWN SPRINKLER SYSTEM l^ijiTEfl SOFTNER TOTAL PL OCC. OP STANDARD PLAN ff DESIGNER'S ADDRESS RES. UNITS AMT. UMBING CONTRACTOR QTY.ELECTRICAL PERMIT NEW CONST EA AMP/SWT/BKR 1 PH .25 3PH EXIST BLDG EA AMP/SWT/BKR 1 PH .25 3PH REMODEL/ALTER PER CIRCUIT TEMP POLE 200 AMPS OVER 200 AMPS TEMP OCCUPANCY (30 DAYS) AMT TOTAL ELECTRICAL CONTRACTOR QTY. PARKING SPACE BUS. LICENSE STATE LICENSE CONTRACTOR'S PHONE — — — I STATE LICENSE DESIGNER'S PHONE NUMBER OF STORIES TYPE CONST MECHANICAL PERMIT INSTALL FURN. OUCTS UP TO 100,000 BTU OVER 100,000 BTU BOILER/COMPRESSOR UP TO 3 HP BOILER/COMPRESSOR 3-15 HP BOILER/COMPRESSOR 16-30 HP VENT FAN SINGLE DUCT MECH EXHAUST - HOOD/DUCTS RELOCATION OF EA FURNACE/HEATER PERMIT NUMBER Hot Valid Unless Hlacliina Certified AMT. TOTAL MECHANICAL CONTRACTOR QTY.MOBILE HOME PERMIT AWNING PORCH SET-UP RAMADA, CABANA FENCE OVER 6' TOTAL MOBILE HOME I HAVE CAREFULLY EXAMINED THE COMPLETED "APPLlCATTON AND PERMIT. AND DO HEREBY CERTIFY THAT ALL INFORMATION HER EON IS TRUE AND CORRECT AND 1 FURTHER CERTIFY AND AGREE IF A PERMIT IS ISSUED; TO COMPLY WITH ALL CITY.COUNTY AND STATE LAWS GOVERNING BUILDING CONSTRUCTION, WHETHERSPECIFIED HEREIN OR NOT. I, ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARM LESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEOUENCE OF THE GRANTING OF THIS PERMIT. AMT. X jp- 5 BUILDING PERMIT SIGN PERMIT PLAN CHECK ALL INCLUSIVE PERMIT TOTAL PLUMBING ELECTRICAL MECHANICAL MOBILE HOME SOLAR O-FILM TOTAL FEES PAYABLE it *AN OSHA PERMIT IS REQUIRED FOR EXCAVATIONS OVER S'-O" DEEP AND DEMOLITION OR CONSTRUCTION OF STRUCTURES OVER 3STORIES IN HEIGHT Jd^ APPLICANT'S SIGNATURE'OWNERQ AGENT O contractorD□ BY PHONE I APMOVEDBY « yy DATEa\ /A^ P /L- 2 w 4^. SITE ADDRESS:OWNER:PERMTT NO: 'I'T'is? FIELD INSPECTION RECORD INSPECTION DATE INSPECTOR WOOD FLOOR FOUNDATION* FORMS •SET BACK •TOILET UNDER FLOOR PLUMBING UNDER FLOOR HEATING OK TO INSTALL SUB FLOOR . » SLAB FLOOR UNDER SLAB PLUMBING FOOTING • FORMS • SETBACK • TOILET OK TO POUR CONCRETE FRAME ROUGH ELECTRICAL ROUGH PLUMBING ROUGH HEATING/VENTILATING FRAME OK • PLACE INSULATION INSULATION OK • PLACE WALLBOARD l\ALLBOARD OK • PLACE TAPE EXTERIOR LATH OK* PLACE STUCCO FIREPLACE DAMPER &STEEL PLATE TIES/HEIGHT OF CHIMNEY OTHER TEMP POWER (POLE) SEWER GAS TEST SWIM POOL • STEEL BONDING • PRE DECK • FENCE PREPLASTER anOWN • FRAME y • PAN / FINAL INSP BY BLDG DEPT / OTHER DEPT'S REQ COMPLETED ELEC METER-PERM-TEMP GAS METER-PERM-TEMP \ \ CERT OF OCCUPANCY ISSUED inspector's NOTES . i>if- r . i,-. -w . . r . jj -it • ■' :•? -'iiT. — w^.i, •- St/i -.T-jf^j -r n - "> \-- ■■ ' -" "-r'.j 1- ■' .-• , _ THE 1987 CORNERSTONE CORPORATION narch 5, 1931 35 City Of Carlsbad^ Carlsbad, Ca. 32003 M O Address in question: Obslisco Uay,' La Costa, Ca. 32003 Owner- Dusan Jevremov C/> o o To whom it may concerns:< s 7 UlB, The 13B7 Cornerstone Corporation have built retaining walls and planter walls at EB32 Gbelisco Ulay, La Costa, Ca. 92003. ^5 We have constructed all walls according to City standards or stranger even thought these walls did not require permit because of their heights. Walls on the mentioned property taller than 3' were constructed before we started our contract. We also removed all existing concrete driveway and lowered grade to accommodate automatic gate. m Dirt removed did not exceeded the 100 yards or less allowed by the City before permit is required. If you have any further question, please contact our office! LU Very truly yours: < Q Z < O in CO ^ . ^1' Tibor Farkas President PHONE: 619/471-0670 619/471-0946 ENGINEERING, INC. 476 W. Vermont Ave., Suite 102 Escondido, California 92025 714-743-1214/727-1818 Job #1159-80 November 18, 1980 Mr. Dushan Jvremov 13155 Porto Del Mar, OA 92024 SUBJECT; Foundation for Retaining Wall Along Street at 2632 Oblisco Place, La Costa, CA Following our discuss:onp of this date, we have prepared the following foundati .r tbcc nerdatr.on for the retaining wall to be located alcrg -'ze front of 2632 O! lisco Place, La Costa, California. A special foundation de-sign will be required for this retaining wall, due tc -he rock-like nature of the soil in the proposed foundation area. Due to the rock-like nature ct the soil, it :.s our recom mendation that the proposed e'ght-focu maxiir^um high wall have a footing that i£ a ■ciini;-ur. of ieet -ieep and four feet wide, with a mrn;mum of .wo #5 lars oz : teel running horizontally throughcvr the footing. The for ling shall also be drilled and pinned t'-e ative, ■ ndist ted, rock-like soil 4^ in-i^hce ce''i'-T pin imbedded a minimum of one foot ir.' . rrt-'vc .-.1' =nd a min imum of 5/8 inch in d: Tire .er- The f( uncatic: shail -e founded a minimum of 4,5 fee*: rom t:: davli-'ht line- If you have any quesr your convenience. MV ENGINEERING, INC .■)ns, please feel free r.o contact us at RCE #25115 RMV:mc ENGINEERING, INC. 476 W. Vermont Ave., Suite 102 Escondido, California 92025 714-743-1214/727-1818 Job #1159-80 October 3, 1980 Mr. Dushan Jvremov 13155 Portofino Dr. Del Mar, CA 92014 SUBJECT: Footing Investigation at 7620 Aldea Place, La Costa, CA. In reply to your inquiry regarding the granite outcrop ping you encountered during the excavation of footings at subject site, in our opinion the most expedient method of laying the rebar through this area would be to drill the granite and pin the rebar to it. This should ensure the footing remains contiguous to the outcropping. MV ENGINEERING, INC. David Houston DH:mc