Loading...
HomeMy WebLinkAbout2635 CREST DR; ; CB020942; Permit10-18-2002 Job Address Permit Type Parcel No Valuation Occupancy Group # Dwelling Units Bedrooms Project Title City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No CB020942 Building Inspection Request Line (760) 602-2725 2635 CREST DR CBAD RESDNTL Sub Type 1561523000 Lot# $14,729 00 Construction Type Reference # 0 Structure Type 0 Bathrooms SUFFREDINI-RAD 143 & BAYWINDOW RAD 0 NEW Status Applied Entered By Plan Approved Issued Inspect Area Orig PC# Plan Check* ISSUED 03/28/2002 JM 10/18/2002 10/18/2002 Applicant CORSCO JOE 4924 PARK DRIVE CARLSBAD CA 92008 760-434-3802 Owner SUFFREDINI PETER J&JOAN £9084 10/18/02 0002 01 CGF"2635 CREST DR CARLSBAD CA 92008 02 159.6ft Total Fees $249 48 Total Payments To Date $89 82 Balance Due $15966 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $13819 $000 $8982 $000 $000 $1 47 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 Meter Size Add'l Reel Water Con Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF PFF (CFD Fund) License Tax License Tax (CFD Fund) Traffic Impact Fee Traffic Impact (CFD Fund) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing InLieu Fee Master Drainage Fee Sewer Fee Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $2000 $000 $000 $000 $000 $000 $000 $249 48 / Inspector FINALAPPR Date -^ *" 'Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 PROJECT INFORMATION Cre-sV FOR OFFICE USE ONLY PLAN CHECK NO EST VAL Plan Ck Deposi Validated Date 1JKA //" Address (include Bldg/Suite #)Business Name (at this address) Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor's Parcel #Existing Use 01 0*' Description of Work i SO. FT *' f>-t;t£^€|O' fO$d^ dd.o.M"ip jr\ uJfth _pa' :2 __CONTACT PERSON;(ff different from applicant) !; * fork Dr. #of Stories ayp///A3 sa fr""- # of Bedrooms #"of Bathrooms Name Address City dkPontractor • d Agentifpr Contractor downer d Agent for Owner*" State/Zip Telephone ff Name [4 PROPERTY OWNER Address City State/Zip Telephone # Name Address City State/Zip Telephone # IS""" cMfrWiCTbW^CbMP^NY'"NAME':"'' " {; «->•*!*>••- • — _ :"i5-' ":"' ":'~.-, .;;..","./ :'^L -TS-- (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law [Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Codel or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500D Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name Address City State/Zip Telephone State License # j6H|WORKERS';COMPENSATION . :.y;.- •7^, C. "I-.,.. .;3" .. /-Tv: . ':""!' ... "".""'.'... ..:... ,.. "~'.:. """•'. """ ' . " :: Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations [~l I have and will maintain a certificate of consent to self-insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued G I have and will maintain workers compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My worker's compensation insurance carrier and policy number are Insurance Company Policy No Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) [3 CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100 000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees SIGNATURE DATE •7' OWNER-BUILDErVDECLARATION " .. . T - , ^'. f'f, • Jji ••.;;•, y- I hereby affirm that I am exempt from the Contractor's License Law for the following reason JES I, as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) ^S^ I* as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) l~l I am exempt under Section Business and Professions Code for this reason I personally plan to provide the major labor and materials for construction of the proposed property improvement J^_YES flNO I (have/ have not) signed an application for a building permit for the proposed work I have contracted with the following V erson (fiu a V to provide the proposed constru Lr Jr T)«- ion (include name / address / phone.nu ' contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) _, PROPERTY OWNER SIGNATURE DATE jlslSECTlbN FOR NON-RESIDENTIAL BUILDINt^ERMITS ONLY" ..Jf Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? l~1 YES l~l NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' d YES Is the facility to be constructed within 1,000 feet of the outer boundary of a school site' d YES d NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT NO I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER'S NAME LENDER S ADDRESS CERTIFICATION :' -vtf;":: rCtr ' ' . ' " '""'^ " ' ' '•'JiU "7 -v^ I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106 4 4 Uniform Building Code) , APPLICANT'S SIGNATURE >^CM>Q__vX«^_/-/-Vfi. o4jUOL-*-> DATE T^l^lX I O"Z- TE File YELLOW Applicant PINK Finance City of Carlsbad Bldg Inspection Request For 04/30/2003 Permit* CB020942 Title SUFFREDINI-RAD 143 & BAYWINDOW Description Inspector Assignment PD Type RESDNTL Sub Type RAD Job Address 2635 CREST DR Suite Lot 0 Location APPLICANT CORSCOJOE Owner SUFFREDINI PETER J&JOAN E Remarks CALL WITH ETA Phone 7608223802 Inspect Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By JOE Entered By CHRISTINE Act xi Comment Associated PCRs/CVs Inspection History Date Description Act Insp 03/19/2003 17 Interior Lath/Drywall AP PD 03/17/2003 16 Insulation AP PY 03/07/2003 34 Rough Electric WC PY 03/07/2003 84 Rough Combo PA PY 02/04/2003 14 Frame/Steel/Bolting/Weldmg WC PD 02/04/2003 83 Roof Sheathing/Ext Shear AP PD 01/23/2003 14 Frame/Steel/Bolting/Weldmg PA PD 01/14/2003 11 Ftg/Foundation/Piers AP PD 12/12/2002 11 Ftg/Foundation/Piers CO SR Comments NEED TEMP GLASS GROUND METAL BOX TIGHTEN SIMPSON BOLTS FLR FRAME GROUT STEEL OK/NEED HARDWARE IN PLACE AND SPECL INSP REPORTS c T E:ONSTRUCTION 1.ESTING & JLNG1NEER1NG, INC. ESCOND1DO • TRACY • CORONA • OXNARD • LANCAS1ER • SACRAMENTO INSPECTION REPORT PAGE orPAGE C I L JOH # jO - f "pROJLCI NAME Z5,,,c , -#?&,*/ ADDRESS 7.03S C.&-~i>r r7,irr<r^D CA ARCiimxi p,r_is ENGINEER 43UW& \ [3 Pi CON I RAC I OR <To i? rso Cl o A. INSPEC 1 ION DAI E I "2. / \ 3 / <: PLAN FILE BUX; prRMi r c1- t-S <: x 2.0*? * 01 HER ' *\ * S .. . _ nucm?f"rf4"iKi|NaP£C 1 1UIN <~ _ .^ «'»O T fc = = 7 / SJ rviMPRFTF /• "> MASONRY ( )PTCONC Jfi ~ (-) «• <_& = /W ( ) FIELD WELD ^ST- () SHOP WELDING ;7_ ( ) PILE DRIVING ( ) BATCH PLANT V^ ()EXP. ANCHOR •(M OTHER (2c6A^ REPORT rf MATERIAL IDENTIFICATION CONC MIX»/PSt 3<? ((C,i4O /3CO0/ GROUT MIX#/PSI MORTAR TYPE/PSI REBAR GRADE /?^-/5/db/7 ^«^/ STR STEEL H S BOLT MAS BLOCK ELECTRODE MATERIAL SAMPLING (V) CONCRETE ( ) MORTAR ( ) GROUT ( ) STRUCTURAL STEEL ( ) BOLTS ( ) FIREPROOFING ( ) MASONRY BLOCK INSPECTION PERFORMED, JOB PROBL PROGRESS, WORK REJECTED, REMARKS Ai _~^r 7-5: ? S". O O V Certification of Compliance: All work, unless < the uniform building code.t with the approved plans and specifications and v!>NAME (PRINT) CERPII-ICAnONNO Q SIGNATURE ^ /..j 7 CEOTECHNICAL& CONSTRUCTION ENGENEERING TESTING & INSPECTION 2414 VINYARP AVKNUi;, SUITE G. ESCONDIDO, CA92029 (760) 746-4955 FAX (760) 746-9806 EsGil Corporation In Partnership with Government for Building Safety DATE 1O/14/O2 a APPLICANT JURISDICTION Carlsbad Q PLAN REVIEWER a FILE PLAN CHECK NO 02-942 SET IV PROJECT ADDRESS 2635 Crest Dr. PROJECT NAME Peter Suffredine Residential Addition The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff 1 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person | | The applicant's copy of the check list has been sent to Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person REMARKS The item clouded in red on sheet 1 of the plans must be made to the city set of plans consistent with the engineer's design. By Chuck Mendenhall Enclosures Esgil Corporation D GA D MB D EJ D PC 10/7/02 trnsmtldot \\\ Corporation In Partnership with Government for Building Safety DATE 9/16/02 a APPJJCANT JURISDICTION Carlsbad a PrANTREVIEWER a FILE PLAN CHECK NO 02-942 SET III PROJECT ADDRESS 2635 Crest Dr. PROJECT NAME Peter Suffredine Residential Addition The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Joe Corsco 4924 park Dr, Carlsbad, CA 9<2 oo&- Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Joe Corsco Telephone # (760) 434-3802 Date contacted ^ji 7/02. (by v*—) Fax # Mail v—Telephone—^" Fax In Person REMARKS By Chuck Mendenhall Enclosures Esgil Corporation D GA D MB D EJ D PC 9/10/02 tmsmtldot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576 Carlsbad 02-942 9/16/02 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 14 Provide calculations for mam vertical and horizontal framing members and footings Section 106 3 3 This applies to the existing 4X8 & 4X10 beams supporting the existing and new roof/deck loads and to the lateral support of the building using the Simpson Strong walls in transverse direction and no lateral support in the longitudinal direction. CALCULATIONS WERE NOW PROVIDED. THE FOLLOWING APPLY AS A RESULT OF THE CALCULATIONS: A. BEAM SUPPORT THE CANTILEVERED DECK JOISTS MUST BE 5- 1/4X14. SEE 3 OF THE CALC'S. THE PLANS SHOW A 4X12. B. THE DESIGN CALC'S DID NOT INCLUDE A JUSTIFICATION FOR THE SIMPSON STRONG WALLS SHOWN ON THE PLANS. C. SPECIAL INSPECTIONS REQUIRED FOR ALL FIELD WELDING AND THE INSTALLATION OF THE A325 HS BOLTS SHOWN IN THE CONNECTIONS. D. THE OMRF CONNECTIONS MUST BE DESIGN FOR Q X THE DESIGN SEISMIC SHEAR AND MOMENT. SEE UBC 2213 6, ITEM 2 SUBMIT REVISED SHOWING THE DESIGN OF THE CONNECTIONS USING Q. FACTOR AS REQUIRED BY THE CODE. E. COMPLETE THE ATTACHED CITY SPECIAL INSPECTION PROGRAM FORM. • ENERGY CONSERVATION 15 Provide plans, calculations and worksheets to show compliance with current energy standards The energy design form CF-1R was provided but the entire computer design energy documents were not provided. COMPLETE DOCUMENTATION WAS NOT PROVIDED. Carlsbad 02-942 9/16/02 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation Thank you Carlsbad 02-942 9/16/02 City of Carlsbad Building Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No CB02-942 Job Address or Legal Description 2635 Crest Dr Owner Sufferedme Address same You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet Carlsbad 02-942 9/16/02 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: PLAN CHECK NUMBER. OWNER'S NAME: I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special mspector(s) as required by Uniform Building Code (DEC) Section 1701 1 for the construction project located at the site listed above UBC Section 106 3 5 Signed I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106 3 5 for the construction project located at the site listed above Engineer */Architect s Seal & Signature Signed 1 List of work requiring special inspection- D Soils Compliance Prior to Foundation Inspection D Field Welding n Structural Concrete Over 2500 PSI Q High Strength Bolting CD Prestressed Concrete d Expansion/Epoxy Anchors D Structural Masonry D Sprayed-On Fireproofmg D Designer Specified D Other 2. Name(s) of mdividual(s) or firm(s) responsible for the special inspections listed above. A B. C. 3. Duties of the special inspectors for the work listed above- A B. EsGil Corporation In yartne.Tsfi.ip with government for 'Building Safety DATE 5/21/02 Q JURIS JURISDICTION Carlsbad Q>tWTfEViEWER a FILE PLAN CHECK NO 02-942 SET II PROJECT ADDRESS 2635 Crest Dr. PROJECT NAME Peter Suffredine Residential Addition The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Joe Corsco 4924 park Dr, Carlsbad, CA <?2oo& Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Joe Corsco (V-H) Telephone # (760) 434-3802 Date contacted s|z2-/o2(by ^ ) Fax # Mail ^Telephone ^ Fax In Person REMARKS By Chuck Mendenhall Enclosures Esgil Corporation GA D MB n EJ D PC 5/13/02 tmsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 Carlsbad 02-942 5/21/02 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 2 All sheets of plans must be signed by the person responsible for their preparation (California Business and Professions Code) Plans are not signed. • FRAMING 11 Why does the floor framing plan show 2X6 rafters @ 16" OC but the section shows 2X10 ripped to 2X8? Clarify your intent The floor plan on sheet 2 still lists the rafters as 2X6 @ 16" OC. 12. Detail the connection of the new roof/deck joists to the existing building Detail A/2 does not show how the new 4X14 is connected to the existing beams 14 Provide calculations for mam vertical and horizontal framing members and footings Section 106 3 3 This applies to the existing 4X8 & 4X10 beams supporting the existing and new roof/deck loads and to the lateral support of the building using the Simpson Strong walls in transverse direction and no lateral support in the longitudinal direction. NO CALCULATIONS WERE SUBMITTED WITH THE RECHECK. • ENERGY CONSERVATION 15 Provide plans, calculations and worksheets to show compliance with current energy standards The energy design form CF-1R was provided but the entire computer design energy documents were not provided. Carlsbad 02-942 5/21/02 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation Thank you EsGii Corporation In Tartnersftip With government for 'Duifcfing Safety DATE 4/8/02 a APj _JUF JURISDICTION Carlsbad a PLAN REVIEWER Q FILE PLAN CHECK NO 02-942 SET I PROJECT ADDRESS 2635 Crest Dr. PROJECT NAME Peter Suffredini Residential Addition The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Joe Corsco 4924 Park Dr, Carlsbad, CA 9-2 oo ? Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Joe Corsco (\/.M) Telephone # (760) 434-3802 Date contacted ^ HAxi (by ^ ) Fax # Mail "^ Telephone ^ Fax In Person REMARKS By Chuck Mendenhall Enclosures Esgil Corporation D GA D MB n EJ D PC 4/1/02 tmsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 +• (858)560-1468 + Fax (858) 560-1576 Carlsbad O2-942 4/8/02 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO O2-942 PROJECT ADDRESS 2635 Crest Dr. FLOOR AREA 143 REMARKS DATE PLANS RECEIVED BY JURISDICTION DATE INITIAL PLAN REVIEW COMPLETED 4/8/02 JURISDICTION Carlsbad STORIES one HEIGHT 9ftapprox Per UBC DATE PLANS RECEIVED BY ESGIL CORPORATION 4/1/02 PLAN REVIEWER Chuck Mendenhall FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Present California law mandates that residential construction comply with the 1998 edition of the California Building Code (Title 24), which adopts the following model codes 1997 UBC, 1997 UPC, 1997 UMC and 1996 NEC (all effective 7/1/99) The above regulations apply to residential construction, regardless of the code editions adopted by ordinance The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad O2-942 4/8/O2 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 2 All sheets of plans must be signed by the person responsible for their preparation (California Business and Professions Code) 3 Note on the plans that smoke detectors are required in the following locations a) Inside each bedroom b) Centrally located in corridor or area giving access to sleeping rooms c) On each story 4 Glazing in the following locations should be of safety glazing material in accordance with Section 2406 4 the 4040 window located within 24" of the new door must be tempered or safety glazing 5 Provide a handrail for the porch steps or show that there are less than 4 risers (3 riser max) • ROOFING 6 Detail the connection of the new guardrail to the roof/deck Detail on the plan the method of water proofing the guardrail connection to the roof 7 Show roof drains through the guardrail Sections 1506 2 and 1506 3 • FOUNDATION REQUIREMENTS 8 Show on the foundation stem wall detail that the stem wall block is solid grouted 9 Show on the plans the required raised floor foundation ventilation at 1 sq ft /150 sqft 10 Hold downs are required, note on plan that hold down anchors must be tied in place prior to foundation inspection Section 108 5 2 Carlsbad O2-942 4/8/02 • FRAMING 11 Why does the floor framing plan show 2X6 rafters @ 16" OC but the section shows 2X10 ripped to 2X8? Clarify your intent 12 Detail the connection of the new roof/deck joists to the existing building 13 Double the floor joists that support the cantilevered joists at the window pop out 14 Provide calculations for mam vertical and horizontal framing members and footings Section 106 3 3 This applies to the existing 4X8 & 4X10 beams supporting the existing and new roof/deck loads and to the lateral support of the building using the Simpson Strong walls in transverse direction and no lateral support in the longitudinal direction. » ENERGY CONSERVATION 15 Provide plans, calculations and worksheets to show compliance with current energy standards 16 The window schedule shall clearly describe the required U-factor and solar heat gam coefficient (SHGC) values and demonstrate compliance with the Title 24 energy calculations 17 The regulations require a properly completed and properly signed Form CF-1R to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design 18 All energy items shown on the plans must be m agreement with the information shown on the properly completed Form CF-IR 19 Note on the plans "The manufactured windows shall have a label attached certified by the National Fenestration Rating Council (NFRC) and showing compliance with the energy calculations " To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation Thank you Carlsbad O2-942 4/8/02 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PREPARED BY Chuck Mendenhall BUILDING ADDRESS 2635 Crest Dr. PLAN CHECK NO O2-942 DATE 4/8/02 BUILDING OCCUPANCY R3 TYPE OF CONSTRUCTION VN BUILDING PORTION rm add Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 143 cb RIHn E><armih FPO h\/ OrHinanro i ^ Valuation Multiplier City Est By Ordinance Reg Mod VALUE ($) 14,729 $13819 Plan Check Fee by Ordinance $8982 Type of Review 0 Complete Review Structural Only CH Repetitive FeeRepeats D Other ,—, Hourly Hour Esgil Plan Review Fee $77.39 Comments Sheet 1 of 1 macvalue doc Carlsbad O2-942 9/16/02 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION- PLAN CHECK NUMBER <3'2.- 042. OWNER'S NAME: I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special mspector(s) as reafuyed by Uniform Building Code (UBC) Section 1701 1 for the construction project located/alt toe site listed above UBC Section 106 3 5 Signed I, as the engmeerMrchitect of recqrj] program as required by UBCj above Engineer i/A/chitoct i Seel that I have prepared the following special inspection the construction project located at the site listed & Signature rk requiring special inspection Soils Compliance Prior to Foundation Inspection Structural Concrete Over 2500 PSI Prestressed Concrete Anchors Structural Masonry Fireproofmg Designer Specified D Field Welding £3 High Strength Bolting Q Expansion/Epoxy D Sprayed-On D Other 2. Name(s) of mdividual(s) or firm(s) responsible for the special inspections listed above B. C. 3. Duties of the special inspectors for the work listed above A. B. D D PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No CB Planner C~a" fc APN Q*Address Phone (760) 602- Type of Ptaject & Use Zoning l^-^l i ^ \jeneral Plan CFD (in/out) #_Date of participation Net Project Density DU/AC Facilities Management Zone v Remaining net dev acres _ Circle One (For non-residential development Type of land used created by this permit ) Legend ^ Item Complete l~"i Item Incomplete - Needs your action Environmental Review Required YES NO TYPE DATE OF COMPLETION Compliance with conditions of approval7 If not, state conditions which require action Conditions of Approval Discretionary Action Required APPROVAL/RESO NO PROJECT NO YES NO TYPE DATE OTHER RELATED CASES Compliance with conditions or approval7 If not, state conditions which require action Conditions of Approval I I [~1 Coastal Zone Assessment/Compliance Project site located in Coastal Zone7 YES NO CA Coastal Commission Authority7 YES NO If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402^^-97767-2370 Determine status (Coastal Pe^FrfltRequired or Exempt) Coastal Permit Determwra^fion Form already completed7 YES NO If NO, complete Cerastal Permit Determination Form now Coastal PeriprfDetermmation Log # Follow-Up Actions 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans) 2) Complete Coastal Permit Determination Log as needed I I I I Inclusionary Housing Fee required YES NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993 ) Data Entry Completed7 YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE') H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 DO D Site Plan: 1. Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right- of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). 2. Provide legal description of property and assessor's parcel number Policy 44 - Neighborhood Architectural Design Guidelines 1 Applicability: YES NO. 2 Project complies YES_ Zoning: 1. Setbacks. Front: > Interior Side: Street Side: Top of slope1 Required Required Required Required Required 2$Shown Shown Shown Show show HO S' CH D CD 2 Accessory structure setbacks* Front. Interior Side: Street Side- Rear: StructuTe~separation 3. Lot Coverage 4 Height Required Requi red Required Required Required Required 1,2,1•^^Ji S Spaces Required5. Parking (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces RequiredShown wn Shown Shown Shown Shown Shown Shown Shown l~l i~l Additional Comments 'e>J~ we OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB DATE ADDRESS RESIDENTIAL ADDITION MINOR « $10,000.00) TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER DATE ENGINEER DATE Docs/Misforms/Plannlng Engineering Approvals AT- S7T ?.5- t Vi O ' ' . . It e-/ & /Z. Z & 12. •L. __ -t- 2. - ^-*- 2.OEu . M * /<T'-J" ?. 4v2-z4-/- &.2XX./3&3 = J&-?^o \^ JK& 1 I 1 -\ ^N « K 4 4*± , \r P s L_J ' I /.?3 x/ s. 4- Afa - /. a J £44 1^724 •fcs 7 /J>s/x ^2 £ Vr» **l *Q17> «-7 ^ 5 W <£.<£> 71 1/4 f 7&X. v •t*//. A 0 O 0 0 Pfefh? N Aa, 4/ - 2. //.Z /#<L 7- pi Try 4 -**<£>- 3. - 7 1 1 -'<:3 /> TI ,4' ' 7- -_^< Trial I Try r 1 1 ri & £ '-? xrz. s«&T>7«/n iv] 4 -**<*> A 6 ) ^ -(74,* -6* £? 2 66 ' ft*") - y 3/ -7-24-671 Are? JL = t * /z. /P " v%f' L'/ « T •7-z. t/t#L ~Z.~X.~2 X<i. /f •2ij. - 4.4 /,2- Af-Z. A 7'Z Z/.Z -2/.Z fi - o / 4 Z /? ir - ' ^ 1Z. - ^9,0 l/n < 4* y• ^ *- ^ -/ r z.4" s-1> 12." d 4*4 tf/L. =• -o -Z. --- m— e. 1 I,1 II i '7- A P\an Frame Static Analysis Report Project sufTredini4 (C \Program FilesXEagle Point Software\Fnilnel5e\projecti\sulTVcdim4) E>cscnption , Date 09/24/2002 01 45 PM Company User Software Eagle Point Frame Analysis & Design Frame Static Analysis Report for suf£redini4 Paae 2/7 NODAL COORDINATE BOUNDARY CONDITIONS (P=FIX, S=SUP,M=MASTER/SLAVE) NODE REBAND NO HO X I Units 1 2 3 4 5 6 ELEM KK NO NO Units 1 2 3 4 5 6 7 MAIL NO Ft 1 0 00 2 0 00 3 0 00 4 15 00 5 15 00 6 15 00 PE ALPHA NO Deg 1 2 90 00 2 3 90 00 3 4 90 00 4 5 90 00 5 6 90 00 2 5 90 00 2 5 90 00 DESIGNATION Y Ft 0 00 5 00 13 50 13 50 5 00 0 00 2 N BETA GAMMA Deg Deg -90 00 0 00 -90 00 0 00 0 00 0 00 90 00 0 00 90 00 0 00 0 00 0 00 0 00 0 00 YOUNG ' S MODULUS DDDOOO Z NODE TEMP ALPHA BETA GAMMA DIR XYZXYZ STIFFNESS Ft F Deg Deg Deg K /In /Deg 0 00 0 00 0 00 0 00 0 00 FFSSSF 0 00 0 00 0 00 0 00 0 00 SSS 0 00 0 00 0 00 0 00 0 00 SSS 0 00 0 00 0 00 0 00 0 00 SSS 0 00 0 00 0 00 0 00 0 00 SSS 0 00 0 00 0 00 0 00 0 00 FFSSSF ODE PRISMATIC BEAM ELEMENT LENGTH MAT PROP RELEASE REF OFFSET STIFFNESS TYPE TYPE HE PE TEMP DIR HE PE HE EE Ft F Ft Ft K /In /Deg K /In /Deg 5 00 1 1 8 50 1 1 15 00 1 2 8 50 1 1 5 00 1 1 15 00 1 2 15 00 1 1 MATERIAL PROPERTIES POISSON'S THERMAL MASS WEIGHT RATIO COEFF DENSITY DENSITY Units 1 Steel K /In A2 2 9e+004 F Slug/FtA3 0 295 6 5e-006 15 2 Lb/Ft "3 490 PROP DESIGNATION Units 1 W12x40 2 W12X40 2 NODE A In" 2 11 t 11 £ PRISMATIC BEAM ELEMENT PROPERTIES IXX IYY J IXY SFY SFX CW In~4 In"4 In"4 InA4 In"6 1 310 44 1 0 95 03 350 1 431 1 44e+003 1 310 44 1 0 95 03 350 1 431 1 44S+003 2 NODE PRISMATIC BEAM ELE REC LOAD LOAD DIST NO TYPE SYS SPEC DIST PX PY NT LOAD INFORMATION PZ MX MY Units DESCRIPTION LOAD CASES ELEMENT LIST 2 3 Ft K K K Ft-K Ft-K Ft-?: LINK GLO FRAC 0 000 1 000 0 000 0 000 -1 360 -1 360 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 Frame Static Analysis Report for suffredini4 Page 3/7 DEC NODAL LOADS HO ALPHA BETA GAMMA PX PY PZ Units Deg Deg Deg K K K i DESCRIPTION LOAD CASES 2 NODE LIST 3 MX MX MZ Ft-K Ft-K Ft-K 0 00 0 00 0 00 1 890 0 000 0 000 0 000 0 000 0 000 STRUCTURE LOAD COMBINATIONS COMB LIST OF FACTORS * CASES DESCRIPTION Combl 1 1 400*1 DESCRIPTION Comb2 2 1 000*1,1 000*2 NODE LOAD NO CASE Units 1 1 2 2 1 2 3 1 2 4 1 2 5 1 £. 6 1 2 DX NODAL D (* Indicates Displaced DY In 0 0000 0 0 0 0 0 0 0 0 0 0 0 0000 0000 0064 0000 0338 0000 0319 0000 0073 0000 0000 In 0 0000 0 0 -0 0 -0 0 -0 0 -0 0 0 0000 0000 0016 0000 0045 0000 0052 0000 0020 0000 ocoo ISPLACEMENTS ents Occur in Nodal Local System) DZ OX OY In 0 0000 0 0 0 0 0 0 0 0 0 0 0 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 Deg 0 0000 0 0 0 0 0 0 0 0 0 0 0 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 Deg 0 0000 0 0 0 0 0 0 0 0 0 0 0 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 oz Deg 0 0000 0 0 -0 0 -0 0 0 0 -0 0 0 0000 0000 0005 0000 0562 0000 0375 0000 0129 0000 0000 NODE PRISMATIC BEAM ELEMENT — ELEMENT REPORTS ELEM LOAD NODE NO CASE NO AXIAL TORSION SIGN CONVENTION BEAM DESIGNERS SHEAR X MOMENT Y MAX MOM/DEPL DIST SHEAR Y MOMENT X MAX MOM/DEFL DIST Units REPORT TYPE ELEMENT LIST 1 1 ;. Max 1-7 i 2 1 2 K Forces Full 0 0000 0 0000 -9 0082 -9 0082 K -Ft 0 0 0 0 0000 0000 0000 0000 K 0 0 0 0 0000 0000 0000 0000 K -Ft 0 0 0 0 K -Ft / In Ft 0000 0000 0000 0000 K 0 0000 0 0000 1 7283 1 7283 K -Ft 0 0 -4 4 K -Ft / In OCOO 0000 4326 2087 0 0004 Ft 1 12 Frame Static Analysis Report for suffredini4 Page 4/' 2 ELEM LOAD NODE NO CASE NO 2 1 i 2 2 2 2 3 313 4 2 3 4 414 5 2 4 5 515 6 2 5 6 612 5 2 2 5 712 5 2 2 5 HODK LOAD NO CASE Units 1 i 2 6 1 LOAD CASE Units 1 2 NODE PRISM AXIAL TORSION 0 OOOC 0 0000 o oqoo o oooo -9 1103 0 0000 -9 7103 0 0000 0 0000 0 0000 0 0000 0 0000 -3 7435 0 0000 -3 7435 0 0000 0 0000 0 0000 0 0000 0 0000 -10 689" 0 0000 -10 6897 0 0000 0 0000 0 0000 0 0000 0 0000 -11 3918 0 0000 -11 3918 0 0000 0 0000 0 0000 0 0000 0 0000 I 7909 0 0000 1 7909 0 0000 0 0000 0 0000 0 0000 0 0000 1 7909 0 0000 1 7909 0 0000 (* FX K o oooo -1 7283 0 OOOO -0 1617 SUM OF PX K 0 OOOC 1 8900 A T I C B E A SIGN CONVENTION M ELEMENT BEAM DESIGNERS SHEAR X MOMENT Y MAX HOM/DEFL 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO REACTIONS Indicates Reactions Occur in Nodal PY K 0 OOOO 9 0082 0 OOOO 11 3918 PZ K 0 OOOO 0 OOOO 0 OOOO 0 OOOO REACTION SUMMAR APPLIED LOADS PY K 0 OOOO -20 3999 PZ K 0 OOOO 0 OOOO — ELEMENT REPORTS DIST SHEAR Y MOMENT X MAX MOM/DEFL 0 OOOO 0 OOOO 0 OOOO 0 OOOO -1 8535 0 7358 -1 8535 -15 0191 0 0128 0 OOOO 0 OOOO 0 OOOO 0 OOOO 9 7103 -15 0191 19 6463 -10 6897 -22 3645 -0 0830 0 OOOO 0 OOOO 0 OOOO 0 OOOO 3 7435 -22 3645 3 7435 9 4554 0 0127 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 1617 2 3968 0 1617 3 2054 • -0 0017 0 OOOO 0 OOOO 0 OOOO 0 OOOO -0 3511 1 7365 -0 3511 -3 5293 0 0057 0 OOOO 0 OOOO 0 OOOO 0 OOOO -0 3511 1 7365 -0 3511 -3 5293 0 0057 Local System) MX MY MZ K -Ft K -Ft K -Ft 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 4 4326 0 OOOO 0 OOOO 0 OOOO 0 OOOO 0 OOOO 3 2054 Y SUM OF REACTIONS PX PY PZ K K K 0 OOOO 0 OOOO 0 OOOO -1 8900 20 3999 0 OOOO DIST 4 96 7 14 7 27 2 98 2 56 9 97 9 97 Frame Static Analysis Report for suffredini4 Page 5/7 REACTION SUMMARY LOU) SUM OF APPLIED LOADS SUMOPREACTIOBS PX PX PC PX VX PB Frame Static Analysis Report for suffredini4 Page 6/7 • cam IIIT or MCXOBB * CUES LOAD COMBINATIONS 1 COMB 1 (Combl) 1 40 X CASE COMB 2 (Conb2) 1 00 X CASE HOOK LOAD BO 00MB I Units 1 1 2 2 1 2 3 1 2 4 1 2 5 1 2 6 1 2 •o COMB »o axxBL i Units K REPORT TYPE Max Forces Full ELEMENT LIST 1-7 111 0.0000 2 0 0000 21-9 0082 2 -9 0082 2120 0000 3 0 0000 22-9 7103 3 -9 7103 3130 0000 4 0 0000 23-3 7435 4 -3 7435 1 1 + 1 00 <* In nc In 0 0000 0 0000 0 0000 0 0064 0 0000 0 0338 0 0000 0 0319 0 0000 0 0073 0 0000 0 0000 NRCXCH K -Ft 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 X CASE 2 dioatM Displ DY In 0 0000 0 0000 0 0000 -0 0016 0 0000 -0 0045 0 0000 -0 0052 0 0000 -0 0020 0 0000 0 0000 •KID COTVUKX SMttft X M K 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 moummtm Ooovx la 1 01 In 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 tJ 0000 ON MUM DEBMHUU CMOR T tax MOM/I K -Ft K -Ft 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 todal Loeal 8y»t«a) OX OX OE Deg Deg Deg 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 -0 0005 0 0000 0 0000 0 0000 0 0000 0 0000 -0 0562 0 0000 0 0000 0 0000 0 0000 0 0000 0.0375 0 0000 0 0000 0 0000 0 0000 0 0000 -0 0129 0 0000 0 0000 0 0000 0 0000 0 0000 0.0000 1 OWL DZSX MttkR T MOMHT X MBX MGM/DBXi / In Ft K K -Ft K -Ft / In 0 0000 0 0000 0 0000 0 0000 1 7283 -4 4326 1 7283 4 2087 0 0004 0 0000 0 0000 0 0000 0 0000 -1 8535 0 7358 -1 8535 -15 0191 0 0128 0 0000 0 0000 0 0000 0 0000 9 7103 -15 0191 19.6463 -10 6897 -22 3645 -0 0830 DIM Ft 1 12 4 96 7.14 7 27 Frame Static Analysis Report for suffredini4 Page 7/7 • •MuvBC &QAD MODB JRXflH •0 00MB BO axial. TOMZOH SHE i 4 1 < 4 0 0000 0 0000 5 0 OpOO 0 0000 2 4 -10 6897 0 0000 5 -10.6897 0 0000 5150 0000 0 0000 6 0 0000 0 0000 2 5 -11 3918 0 0000 6 -11 3918 0 0000 6120 0000 0 0000 5 0 0000 0 0000 221 7909 0 0000 5 1 7909 0 0000 7120 0000 0 0000 5 0 0000 0 0000 221 7909 0 0000 5 1.7909 0 0000 MOB T-X»T» (* Xnd •0 00MB PX Units K 11 0 0000 2 -1 7283 61 0 0000 2 -0 1617 00MB PX Units K 1 0 0000 2 1 8900 CUMVJUcTXUH kit X MOM 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0.0000 0 0000 0 0000 0 0000 0 0000 iMtW *••" PT K 0 0000 9 0082 0 0000 11 3918 FT K 0 0000 -20 3999 BUM DXSIQHKBS an t M» MOM/DXTL 0 0000 0 0000 0 0000 0 0000 0 0000 0.0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 PC K 0 0000 0 0000 0 0000 0 0000 I A K n •v A U • EE K 0 0000 0 0000 OUT SKUA T MOMEMT X M 0 0000 0 0000 0 0000 0 0000 3 7435 -22 3645 3 7435 9 4554 0 0000 0 0000 0 0000 0.0000 0 1617 2.3968 0 1617 3 2054 0 0000 0 0000 0 0000 0 0000 -0 3511 1 7365 -0 3511 -3.5293 0 0000 0.0000 0 0000 0 0000 -0 3511 1 7365 -0 3511 -3 5293 local •«*•) MX Iff K -Ft K -Ft 0.0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 0 0000 PX PX K K 0 0000 0 0000 -1 8900 20 3999 ax MOM/DETL DISC 0 0127 2 98 -0 0017 2 56 0.0057 9 97 0 0057 9 97 MB K -Ft 0.0000 4.4326 0 0000 3 2054 PB K 0 0000 0.0000 New Section Desc Detailed Report? | Procedure Report' ~[ 09/24/02 09 14 18 AM 2/2 Member 1 2 3 4 5 6 7 NE Node 1 2 3 4 5 2 2 PE Node 2 3 4 5 6 5 5 Section Desc column column beam column column beam column Section W12x40 W12x40 W12x40 W12x40 W12x40 W12x40 W12x40 Status OK OK OK OK OK OK OK Critical Ratio 0065 0256 0176 0328 0065 0030 0030 Governing Criteria Axial-Bending Axial-Bending Axial-Bending Axial-Bending Axial-Bending Axial-Bending Axial-Bending Re-design? XX XX ^H 09/24/02 09 13 17 AM 1/4 Detailed Report? Procedure Report? - KL/r (X) 1754 3499 3509 3102 1754 3509 3509 KLfr(Y) 5938 15961 9326 15961 5938 9326 9326 Axial/ Bending Rato 0065 0256 0176 0328 0065 0030 0030 Critical Interaction Combination Comb2 Comb2 Comb2 Comb2 Comb2 Comb2 Comb2 -Fa (ksi) 2282 586 1623 586 2282 3000 3000 fa(ksi) 076 082 032 091 097 •015 -015 •Fbx (ksi) 3300 3000 3300 3000 3300 3300 3300 fbx (ksi) 1 02 347 517 517 074 082 082 09/24/02 09 13 17 AM 2/4 *Fby(ksi) 3750 3750 3750 3750 3750 3750 3750 fby(ksi) 000 000 000 000 000 000 000 Shear X Ratio 0000 0000 0000 0000 0000 0000 0000 Critical Shear X Combination — — — — — — — *Fvx (ksi) 2000 2000 2000 2000 2000 L2000 2000 fvx(ksi) 000 000 000 000 000 000 000 Shear Y Ratio 0025 0026 0152 0053 0002 0005 0005 Critical Shear Y Combination Comb2 Comb2 Comb2 Comb2 Comb2 Comb2 Comb2 *Fvy (ksi) 2000 2000 2000 2000 2000 2000 2000 fvy(ksi) 049 053 303 106 005 010 010 09/24/02 09 13 17 AM 3/4 TL Allowable <U*) 240 240 240 240 240 240 240 TLDef X Ratio 0000 0000 0000 0000 0000 0000 0000 TLDef X(L/7) — — — — — — — TLDef Y Ratio 0002 0030 0111 0030 0007 0008 0008 TLDef Y(L^) 158402 7974 2169 8025 35640 31505 31505 LL Allowable (L/') 360 360 360 360 360 360 360 LLDef X Ratio 0000 0000 0000 0000 0000 0000 0000 LLDef X(U?) — — — — — — — LLDef Y Ratio 0002 0045 0166 0045 0010 0011 0011 LLDef Y(L/*) 158402 7974 2169 8025 35640 31505 31505 09/24/02 09 13 17 AM 4/4 Member 1 2 3 4 5 6 7 NE Node 1 2 3 4 5 2 2 PE Node 2 3 4 5 6 5 5 Section Desc column column beam column column beam column Section W12x40 W12x40 W12x40 W12x40 W12X40 W12x40 W12x40 Length (ft) 5000 8500 15000 8500 5000 15000 15000 Lx(ft) 500 850 1500 850 500 1500 1500 Ly(ft) 500 850 1500 850 500 1500 1500 Calc «' M R b£i„ H k4 Sway X' 1 Xi — _ IX! IX) Sway Y? 1 ^i IXI H 09/24/02 09 12 06 AM 1/3 TLDef LP 240 240 240 240 240 240 240 LLDef LP 360 360 360 360 360 360 360 Max Depth (in) 36 36 36 36 36 36 36 Mm Ocptn (in) 12 12 12 12 12 12 12 Width (in) 0 : 0 0 0 0 0 0 Back To Back Space (in) 0 0 0 0 0 0 0 Welded' Yield Stress (ksi) SO 50 SO 50 50 50 50 09/24/02 09 12 07 AM 3/3 TLDef L/? 240 240 240 240 240 240 240 LLDef L/' 360 360 360 360 360 360 360 Max Depth (in) 36 36 36 36 36 36 36 Mm Depth (in) 12 12 12 12 12 12 12 Width (in) 0 0 0 0 0 0 0 Back To Back Space (in) 0 0 0 0 0 0 0 Welded? Yield Stress (ksi) 50 SO 50 50 50 50 50 09/24/02 09 12 07 AM 3/3 .fete, <fS O 5,0 >s 0. I M .' n- is nesn c?» T /z" (&/G,"o£, L /- -z.4 3*3 - 2. •=: i,C T < /t ADDITION WORKSHEET Page 1 ADD Project Title Suffredini Nook Addition Date. 05/05/02 20 00:51 Project Address 2635 Crest St. ******* Carlsbad, Calf. *v6.01* | I Documentation Author... David McKinley ******* | Building Permit # I McKinley Engineering | I 1659 James Drive I Plan Check / Date | Carlsbad, CA 92008 | | 760-434-3750 I Field Check/ Date | Climate Zone 07 Compliance Method MICROPAS6 v6 01 by Enercomp, Inc. I MICROPAS6 v6.01 File-PETNOXG Program-ADDITIONS I I User#-MP1707 User-McKinley Engineering Run-Suffredini Exist + Addn | ADDITION/ALTERATION WORKSHEET - COMPUTER PERFORMANCE EXISTING File Name PETNOXG - Suffredini Existing Conditioned Floor Area 1796 sf Standard Design Energy Use. 20.28 kBtu/sf-yr Proposed Design Energy Use. 48.38 kBtu/sf-yr NEW (EXISTING PLUS ADDITION/ALTERATION) File Name PETNOXA - Suffredini Exist + Addn Conditioned Floor Area 1956 sf Standard Design Energy Use. 20.29 kBtu/sf-yr Proposed Design Energy Use. 45.55 kBtu/sf-yr FLOOR AREA RATIO Floor Existing New Area Floor Area Floor Area Ratio 1796 / 1956 = 0.918 DESIGN ENERGY USE FOR NEW (EXISTING PLUS ADDITION/ALTERATION) Floor Addition/ New Area Existing Existing Alteration Standard Ratio Proposed Standard Design 20 29 + 0.918 x ( 48.38 - 20.28) = 46.09 Note. If (Existing Proposed - Existing Standard) is negative, this difference is set to zero ADDITION/ALTERATION ENERGY USE SUMMARY Addition/ Energy Use Alteration Proposed Compliance (kBtu/sf-yr) Design Design Margin New 46.09 45.55 0.54 *** Addition/Alteration complies with Computer Performance ***