Plumbing/Mechanical/Electrical (PME) Permit
Permit No: CBI51765
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Reference #:
PC #:
Project Title:
2636 DAVIS PL CBAD
PME
1552710500 Lot#:
BEESON RES-UPGRADE ELECT PANEL
TO 200 AMP PANEL- FOR PV SYSTEM
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
ISSUED
06/08/2015
RMA
06/08/2015
06/08/2015
Applicant:
RANCHO SOLAR ELECTRIC
Owner:
BEESON FAMILY TRUST 02-29-96 <DVA>
13354 TININGDR
POWAY CA 92064
858-677-6527
2636 DAVIS PL
CARLSBADCA 92008
Plumbing Fees
Electrical Fees
Mechanical Fees
Other PME Fees
$0.00
$0.00
$0.00
$0.00
TOTAL PERMIT FEES $0.00
Total Fees: $0.00 Total Payments To Date: $0.00 Balance Due: $0.00
Inspector:
FINAL APPROVAL^
Date: lllA^^jS. Clearance:
NOTICE; Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
refen-ed to as "fees/exactions." You have 90 days from the date this pemiit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which vou have oreviouslv been given a NOTICE similar to this, or as to which the statute of limitations has oreviouslv othenA/ise exoired.
Inspection List
Permit*: CB151765 Type: PME BEESON RES-UPGRADE ELECT PANEL
TO 200 AMP PANEL- FOR PV SYSTEM
Date Inspection Item Inspector Act Comments
06/25/2015 33 Service Change/Upgrade - Rl
06/25/2015 39 Final Electrical PD AP
06/22/2015 33 Service Change/Upgrade PD AP
06/22/2015 34 Rough Electric - Rl
06/17/2015 31 Underground/Conduit-Wirin - Rl
06/17/2015 31 Underground/Conduit-Wirin PD AP
Friday, June 26, 2015 Page 1 of 1
SDQF
' ^^^^^^^ Energy ubiiiy'
ELECTRIC OVERHEAD METER & SERVICE LOCATION
Customer Copy
Notiflcation #: 300000044671 Job#: TB: 1106-E4
Wanted Data: ON INSPECTION Date Prepared: 05/13/2015
Customer Type: Residential(1-2 Units) Sen/ice Type: OH SERVICE REVWRE«EL0CAT10N
Project Title: BEESON, FLORENCE (SOT)
Project Address: 2636 DAVIS PL Project City: CARLSBAD
Additionai Address Info:
Customer POC: Mike Ganung Customer Phone #: 760-419-2930
SDGE Contact Servioe Coordinator Contact Into: WENDY JENSEN. 760-476-5611
I I Traffic Control Per mit RequirBd • SDG&E Application Required-Can: 1-800-411-7343
Excavation/Encroachment Permits Required By:
Municipal Inspection Required By: CITY OF C/VRLSBAD Temp Servioe Charge due on First Bill $ 0.00
SERVICE ATTACHMENT POINT AND/OR METER LOCATION:
Locate the new point of atladvnent within 18 inches of the sAw comer on the South_ wall of garage. Install rigid riser minimumof2
feet akxjve roof and meet minimum clearances as noted below. Locate new 200 amp meter panel on the South_ wall at/near the s/w_
comer.
Provlda Minimum Ground Clearanca Of:
_10_ Ft From txjttom of drip loop at service wire point of attachment
_12_ FL Over driveway or paridng area
18_ Ft At outer limit of vehicular tnaflic
2 Ft Mnimum rigid riser above roof
Ft
Service Panel Rating: 200 Numt)er/Size of Main Switch: Voltage: 120/240
# of Wires: 3 Phase: 1 Utilities Maximum ContritxJtion to Fault Cun«nt 10000
Metering: Self-Contained Meter Clips: 4
Meter height - 4'0" min. {ZV win. for multiple installation) - 6*3" max. From finish grade to centeriine of meter t>ase. Meters are required to
be readily accessible 24 hours per day. Meters must be located in a safe area free of any potentially hazardous or dangerous condition.
Provide 3-fL x 3-ft. dear and level woridng space in front of meter. Where meter room is proposed, contact the planner at the nearest SDG&E
oflice. Meter bases and meter service disconnects must be located at or immediately adjacent to each other and be identified with address
and unit number it senres.
Additional Information: CH ^'Q^ of VUay Required Assessor's Parcel Number
To minimize the electrical outage, you are advised to schedule a moming disconnect with an aftemoon reconnect There is no charge
for this service. Before you change out your meter consider (1) SDG&E needs advance notioe to schedule a crew and
(2) SDG&E will not reconnect ttie service without municipal approval on ttie new panel. Please contact ttie City/County regarding
permits and inspections.
City/County inspection should be received prior to 2:00 p.m. on the same day as ttie disconnection of service to allow ttie SDG&E
crew enough time for reconnection of ttie service on ttie same day.
tf SDG&E encounters hazanjous or toxic material while performing consbruction of your project, SDG&E will halt wortc immediate and it wHI
be your responsibility to remove and or dean up all hazardous or toxic material prior to SDG&E continuing consbuction. SDG&E shall have no
liability or obligation whatsoever to deanup, remove or remediate any hazardous or toxic matenals discovered during the course of
constiuction unless it is ttirough negligence of SDG&E.
Customer-owned fadlities to receive gas service are sufciject to all applicable local and state of Califomia inspection auttiority requirements.
Building address and/or houseline must be pemnanentiy identified prior to meter set. Infomiation on ttiis sheet is void after six (6) months.
Keep ttiis notice with building pennit
AH InstaMations performed under this order must meet SDG&E standards unless a written deviation has been approved.
I Planned By: Lois Higgins Phone* 7604765613