HomeMy WebLinkAbout2637 GALICIA WAY; ; 76-224; Permit— -: - PERMIT APFLICTION BUILDIt1G$ City of CARLSBAD, CALIFORNIA ','92008- ; Phone 729-1181 Applicant to complete numbered spaces only. Permit No JOB ADDRESS ASSESSORS 2$7 , PARCEL NUMBER. LEGAL I D E S CR. LOT NO. '._jp BLK ,'j . TRACT ..p.,. I . . (E:JSE ATTACHED SHEET) / j ,,,,7 __* _•)f) :' I . BOOK PAGE .P AR. OWNER - ' MAIL ADDRESS ç !31 9 z.,Ig ' PHONE . S f7J4 z'r __ CONTRACTOR MAIL ADDRESS . /, PHONE LICENSE NO. STATE., CITY /f /V - ,,'- ,. .- ARCHITECT OR DESIGNER - MAIL ADDRESS PHONE - LICENSE NO. A '. . • ENGINEER MAIL ADDRESS PHONE LICENSE NO. 5, • . - COMPENSATION INS. CARRIER MAIL ADDRESS BRANCH r i . USE OF BUILDING 8 Class of work: 'NEW LI ADDITION LI ALTERATION LI REPAIR . LI MOVE LI REMOVE 5p 9 Describe work: .• ' : . k; . ' r 10 Change of use froriT' / Change of u>to . ' •. . , • . 5, 11 Valuation of work: .$ . ' . ?. . PLAN CHECK FEE $ 9. • - . . PERMIT-FEE 8" - . SPECIAL CONDITIONS: . ' Type of ' ,/ Const. i Occupancy Grâup MICRO FILM FEE . - Size of Bidg., (Total) Sq. F~O1.E1' No. of Stories Max. 0CC. Load . ' . Fire Zone "3 use . ,f' ' Zone Fire Sprinklers Required DYes -15-No APPLICATION AcCEprEoBY: DATE 67 •. '""s PLANS CHECKED BY. . .ZXATE APPROV&D FOR ISSUANCE BY Dwelling Units/ OFFSTREET PARKING SPACES: Covered Sq.'Ft C) NOTICE / SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMB- ING, HEATING, VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC- TION AUTHORIZED IS NOT COMMENCED WITHIN120DAYS, OR IF ' CONSTRUCTION OR WORK ISSUSPENDEDOR ABANDONED FOR A PERIOD OF, 120 DAYS AT ANY TIME AFTER WORK IS COM- MENCED. . • - . I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE'AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION 'ORT.HE .PERFORMANCE OF -CONSTRUCTION. '—i p .' ••'' _•__.%/ /;-.4 . Special Approvals Required 'Received , Not Required PLANNING DEPT. HEALTH DEPT FIRE DEPT. SOIL REPORT OTHER (Specify) . • ENGINEERING DEPT WATER DEPT. SIGNATURE OF CONTRACTOR o/AUTHORIZED AGENT (DATE) - • SIGNATURE _OF_ OWNER _(IF _OWNER _BUILDER) (DATE) WHEN PROPERLY VALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT PLAN CHECK VALIDATION . . CK. M.O. CASH PERMIT VALIDATION CK. M.O. CASH r576 - • . . . . . ., - ,. , . . . - INSPECTOR , • INSPECTION RECORD DATE REMARKS INSPECTOR FOUNDATIONS: SET BACK • . . TRENCH REINFORCING FOUNDATION WALL & WEATHER PROOFING CONCRETE SLAB •0 - FRAMING . INT. LATHING OR DRYWALL EXT._LATHING - MASONRY USE SPACE BELOW FOR NOTES, FOLLOW-UP, ETC. 3-17-76 Fdn. Forms: O.K. to pour. B. Nelson 3718-76 Concrete pour: O.K. B. Nelson 4-21-76 .Sheathing: O.K. B. Nelson, 4-28-76 See corrections Enclosed. B. Ne1son 5-3-76 Frame: O.K. B. Neslon 5-3-76 Duct O.K. no permit. .B. Nelson- 5-14-76 Drywall:O.K. B. Nelson 5-19-76 Exterior Lath: O.K. B. Nelson - ."- 0..Mir, .. PLUMBING City of Applicant to complete numbered spaces only. - .... PERMIT APPLICATION CARLSBAD, CALIFORNIA , Permit No. _____ - -' f' JOB ADDR ESS • / /1 a•; •/(/ LEGAL 1DESCR. I I LOT NO. OLK TRACT . - OWNER MAIL ADDRESS ZIP PHONE 2!, ' ' T( CONTRACTOR . MAIL ADDRESS PUONE*ç LICENSE NO. STATE CITY V /ARCHITECT OR OJGNER MAIL ADDRESS PHONE LICENSE NO. ENGINEER MAIL ADDRESS PHONE LICENSE NO. 5 COMPENSATION (NS. CARRIER MAIL ADDRESS BRANCH 6 /// USE OF BUILDING 7 8 Class of work: HrNEW U ADDITION U ALTERATION fl REPAIR .9 Describe work:. y/ . /• /. /•-1 I •• / PERMIT FEES No. Type of Fixture or Item Fee SPECIAL CONDITIONS: WATER CLOSET (TOILET) — BATHTUB LAVATORY (WASH BASIN) 4L SI SHOWER KITCHEN SINK & DISP. — 7 DISHWASHER APPLICATION ACCEPTED PLANS CHECKED BY 1APPROVED FOR ISSUANCE BY LAUNDRY TRAY 7 CLOTHES WASHER ( I I WATER HEATER L_ I 1 DATE ,•1 NOTICE URINAL THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC- -4- DRINKING FOUNTAIN,1 1121 1 TION AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A FLOOR--SINK OR DRAIN SLOP SINK PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM- MENCED. GAS SYSTEMS: NO. OUTLETS I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS WATER PIPING & TREATING EQUIP. — — APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT WASTE INTERCEPTOR TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED VACUUM BREAKERS — — PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING LAWN SPRINKLER SYSTEM CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. 1171 SEWER 3 /> CESSPOOL — — — SEPTIC TANK & PIT ROOF DRAINS SIGNATURE OF CONTRACTOR OS AUTHORIZED AGENT (DATE) — — PERMIT $ TOTAL FEE $ ._BUILOERI SIGNATURE _OF_ OWNER _(IF _OWNER (DATE) WHEN PROPERLY VALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT PLAN CHECK VALIDATION CK. M.O. CASH PERMIT VALIDATION CK. M.O. CASH INSPECTOR INSPECTION REPORTS - DATE ITEM REMARKS -. INSPECTOR USE SPACE BELOW FOR NOTES, FOLLOW-UP, ETC. - 3-12-76 See corrections enclosed. B. Nelson 3-15-76 Copper, waste, sewer connection: O.K. B. Nelson 2 -7 5-3-76 Gas and Rough: 0. K. B,.- Nelson • • • • - - - • -•- • - - • • • • ELECTRICAL PERMIT APPLICATION - City of CARLSBAD, CALIFORNIA 92008 . Applicant to complete nurnered spaces only. Phone 729-1181 PeLrr1 it No. JOB ADDR ESS 2Xi (. LEGAL 1, ESC LOT NO. . • I BLE TRACT ATTACHED SHEET) OWNER MAIL ADDRESS IP PHONE 2 CONTRACTOR MAIL ADDRESS PHONE LICENSE NO. STATE CITY 3 . - W11 40 ARCHITECT OR DE5IGN.R MAIL ADDRESS PHONE LICENSE NO. 4 ENGINEER MAIL ADDRESS PHONE LICENSE NO. 5 COMPENSATION INS. CARRIER MAIL ADDRESS . BRANCH USE OF BUILDING - 1 * 8 Class of work: YNEW 0 ADDITION 0 ALTERATION 0 REPAIR 9 Describe work: /L' / If_ PERMIT FEES ISSUANCE OF EACH PERMIT No. Each Fee V SPECIAL CONDITIONS: . . . I -Ile NEW CONSTRUCTION, FOR EACH AMPERES OF MAIN SERVICE, SWITCH, - FUSE OR BREAKER ___________________ ___ ____ APPLICATION ACCEPTED BY: .4 f_I PLANS CHECKED BY: APPROVED FOR ISSUANCE BY: DATE NEW SERVICE ON EXISTING BLDG. FOR EA. AMPERE OF INCREASE IN MAIN SERVICE, SWITCH, FUSEJ. oo,- (4 1p - NOTICE THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC. OR BREAKER TION AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF - CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM. MENCED. REMODEL, ALTERATION, NO CHANGE IN SERVICE, FOR EA. AMPERE OF I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. INCREASE - TEMP. SERVICE UP TO AND INCLUD- ING 200 AMP. ) -01 1 . TEMP. SERVICE OVER 200 AMP. PER 100 SIGNATURE OF-CONTRACTOR QR AUTHORIZED AGENT (DATE) - PERMIT FEE . SIGNATURE _OF_ OWNER _(IF _OWNER _BUILDER) WHEN PROPERLY VALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT PLAN CHECK VALIDATION CK. M.O. CASH PERMIT VALIDATION CK. M.O. CASH INSPECTOR , : V - INSPECTION REPORTS DATE - ITEM . REMARKS INSPECTOR V V USE SPACE BELOW FOR NOTES, FOLLOW-UP, ETC. V 3-25-76 Tern;. Elec. O.K. B. Nelson V V V 5-3-76- Rough elec. O.K. B. Nelson V V V ' V V ' 'V_V • V ' V ' V / V VV V Vt V V V. V - ,V11 MECHANICAL PERMIT APPL[CATIjr.ON.. 01 Per t N _________ City of CARLSBAD, CALIFORNIA 92008 Applicant to complete numbered spaces only. . Phone 729-1181.. JOB ADDRESS Af tgzC/q OT7 LEGAL 1 E CR. T TRACT (SEE ATTACHED SHEET> OWNER MAIL ADORES 2 9 ? ZIP PHD E CONTRACTOR '.4A IL ba ESS 44 #te/t ' I4ORZNE' &T ALRE7 tl fEPON ENGINEER MAIL ADDRESS 5 . PHONE LICENSE NO. - •-_ .--- - - LENDER MAIL ADDRESS 6 BRANCH USE OF BUILDING 7 8 Class of work: R1 NEW, 0 ADDITION 0 ALTERATION 0 REPAIR - - - - - - 9 Describe work: -- &' JAU - 0 - - / Type of Fuel: Oil 0 Nat. Gas ) LPG. 0 PERMIT FEES SPECIAL CONDITIONS: No. Type of Equipment Fee Air Cond. Units—H.P. Ea. $ Refrigeration Units—H.P. Ea. Boilers—H.P. Ea. Gas Fired A.C. Units—Tonnage Ea. - Forced Air Systems—B.T.U. M Ea. , APPLICATION ACCEPTED BY: ( PLANS CHECKED BY: - APPROVED FOR ISSUANCE BY: ' Gravity Systems—B.T.U. M Ea. Floor Furnaces—B.T.U. M Wall Heater—B.T.U. M - NOTICE THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC- TION AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM- MENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. Unit Heaters—B.T.U. M - Evaporative Coolers Clothes Dryers - - Ventilation Fan D U Range 00 - - Air Handling Unit— C.F.M . Incinerator - - - SIGNAT'iJRE OF CONTRACTOR OR AUTHORIZED AGENT (DATE) PERMIT $ TOTAL FEE $ SIGNATURE OF OWNER (IF OWNER BUILDER) (DATE) WHEN PROPERLY VALIDATED (IN THIS SPACE) THIS IS.YOUR PERMIT - PLAN CHECK VALIDATION CK. M.O. CASH PERMIT VALIDATION CK. M.O. CASH INSPECTOR INSPECTION REPORTS DATE ITEM REMARKS INSPECTOR J USE SPACE BELOW FOR NOTES, FOLLOW-UP, ETC. Aft BUILDING DEPARTMENT RJJILDING ADDRESS:...._ INTERDEPARTMENTAL INFORMATION SHEET j RThEOVED JAN 29 1976 5 f - - - '' • L.JU1# - ~ Bwldtng Department PLANNING DEPARTMENT It 1c.? LOT SIZE" -• LOT WIDTI-1 (" ZONE UNITS PROVIDED ALLOWED PR KG. SPACES PROV,DED_2 _REQ.______ %OF COVERAGE ALLOWED BLDG HEIGHT 140 ALLOWED$ FRONT SETBACK SIDE YARD' REAR YARD 60000 INTRUSIONS_________ ENVIRONMENTALPROTECTION REQ'TS. _ LANDSCAPE PLAN C - ADDITIONAL C MMENTS Am ' Atli PERMIM,"kXWA-TE_j0_*' CUPANC ENGINEERINGDEPARTMENT R.OW.__-7i/11 _INDUSTRIAL WASTE 1 IMPROVEMENTS _KrrtJCt'-SEWER CONNECTION ' -DRIVEWAY LOCATIONS_?r'(rr ZeWIV4 GRADING-PERMIT____________ EASEMENTS ' LEGAL DESCRIPTION _Lr- S L4— CPr r/t44 14& I t.4rP ' (1 I .., . ADDITIONAL COMMENTS_____________________________________________________________ ISSUE PERMIT DATE OCCUPANCY_ DATE it _________ - /0— .. i l WIRE DEPARTMENT ' SPRINKLING SYSTEM ' FIRE PROTECTION EQUIPMENT IRE ALARMS____________________ EXITS FIRE HYDRANTS LOCATION_____________________________ ADDITIONAL COMMENTS. ISSUE PERMIT . DATE OCCUPANCY_ WATER DEPARTMENT C M W D CARLSBAD- OLI ADDITIONAL COMMENTS_________ DATE________ jSANOS ISSUE PERMIT _DATE OCCUPAN I SENT TO PLANNING RETURNED TO BLDG. SENT TO G. NE RETURTO BLDG. DEPT, LEUCADIA COUNTY WATER DISTRICT APPLICATION FOR SEWER SERVICE Phone No.753-6804 Owner's Name: George Farr Mailing Address: 2439 Sevilla Way Carlsbad, Calif. 92008 Service Address: Galicaia Way Tr'ct Description: La Costa South 1 lot 95 Type of Building:'_single No. Units 1. Lateral Size: 4" 6" 81.' Saddle: Extra footage: @ $ Easement Connection Extra depth: - - -- @ $ Amount Rec'd $ 500.00 How Paid ck #24.96 . Date Paid 2-26-76 Rec'd b)G. Franklin Connection Charge$500.00 Lateral Charge Total $500.00 The application must be signed by the owner. (or his authorized representative) of the property to be served. The total charges must be paid to the District at the time the application is submitted. If a service lateral is required, it will be installed by the Leucadia County Water District. The service lateral is that part of. the sewer system that extends from the main collection line in the street (or easement) to -the point in the street (at or near the applicant's property line) where the service.-lateral is connected?to the applicant's building sewer. . The applicart is responsible for the-construction,-at-the applicant,s expense, of the sewer pipeline (building sewer)from the applicant'splumbing to the point in the street (or easement) where a connection is made to the service lateral. The connection of the applicant's building sewer to the service lateral -shall be made by the applicant at his expense. The connection must be made in conformity with the District's specifications, rules and regulations; and IT MUST BE INSPECTED AND APPROVED BY THE DISTRICT BEFORE THE SEWER SYSTEM MAY BE USED BY THE APPLICANT.. THE APPLICANT, OR HIS AUTHORIZED REPRESENTATIVE, MUST NOTIFY THE DISTRICT AT THE TIME INSPECTION IS DESIRED. ANY CONNECTION MADE TO THE SERVICE LATERAL OR COLLECTION LINE WITHOUT -PRIOR APPROVAL AND INSPECTION BY THE DISTRICT WILL BE CONSIDERED INVALID AND WILL NOT BE ACKNOWLEDGED. After connection is complete, the property described above is subject to .a monthly sewer service charge, billed bi-monthly in advance. The rate will be governed by the use of the property, single family, multiple dwelling or commercial.' Non-payment of the sewer service, charge is subject to a 5% penalty per month, plus disconnection if necessary. The unde igned hereby agrees that the above information given is correct and agrees to the co state ),1 . 2-26-76 . , 4786 Owner Signature Date Account No. NEW CONSTRUCTION VALUATION WORK SHEET , - PLAN CHECK Types Of Construction: . I & II - Steel, Concrete, or Masonry with Floors and Walls Steel or Concrete. III Masonry Walls, Wood Floors and Interior Walls (Except 1st floor could have conc. slab) IV - Steel - W'" EVERY BUILDING REUIPES A SEPARATE PERMIT • GIUP • . 0 DESCRIPTION . - SF Of Floor Area ______ Cost/SF for. Types of Construction Valuation I & II ______ III .111-N 1Hr. V-lhr V A, B, Auditoriums,Theater Churhes, Schools 41.00 32.00 30.00 2940 . 27.10 D . . Hospitals . 56.00 53.70 - 45.60 - • convalescent Hares 40.30 37.20 - 33.20 - E, F, Industrial Plants 21.90 . 16.00 1'3.90 14.00 12.10 or.G Tilt-Up 12.10. 10.20 StockTypeIV - - - 14.30 12.10 Warehouses 17.60 14.00 11.80 12.30 10.10 OfficeAreas Sameas Office Bldgs. - Stores &Cc!n'l.Bldg4 30.40 23.30 21.29 21.00 18.90 F Office Bldgs. [_________ 2Q00 26J0_.1 24.00_. 21.80 Restaurants I _____ - 3520 3300 31.90 29.70 Service Stations J - 30.00 28.00 18.90 - Canopies (Service) . IV.1L 9.60 _• Public Garages 1 18.30 1530 13.10 13.10 13.10 H APTS. , HOTELS, MYI'E1S 31.40 24.50 - 22.50 21.70 I Type I Garage '7/ J 13.60 - 24.30 - 22.60 LrLINGs ç)r5 . - I & H Patios Porches, Balconies .. , ) 7 0 . 5.00 /5T6 Baserrent Garages . . - - 13.60 J Attached- Priv. Gar. 9.70 - 7.40 Carports-Open . 5.00 Fire-Extinguishing Sprinkler System . Add .60 per sq. foot of [Area Sprinkled 11K Air-Conditioning1 Commercial Add $2.00 Sq. Ft. Residential $1.25 Sq. Ft. TOTAL VALUATION: MICRO FILM FEE: Pile Fdns. Cast in Place $4.00 LF Steel & Pre-Cast-$8.00 LF . PLAN CHECK FEE: 7 5 14X 0 • 0 - BLDG. PERMIT TOTAL PERMIT FEE: OWNER: UM) 729-1Ull, )",'XL. 48 CITY OF CARLSI3AD BUILDING DEPARTMENT SINGLE FAMILY AND MULTIPLE FAMILY °RESIDENTIAL'PLAN .,-.. CORRECTION LIST S - WARNING: PLAN CHECK FEES, WHERE NO ACTION IS TAKEN BY THE APPLICANT IN 120 DAYS, AND NO BUIlDING tERMITIS ISSUED, ARE FORFEITED TO THE CITY. OCCUPANCY - TYPE OF CONSTRUCTION BASICAJA13LE BUILDING AREA: 1st Floor 3rd-Floor FIRE> ZONE VALUATION 2nd Floor 4th Floor JOB ADDRESS: OWNER: CONTRACIOR: ENGINEER: ARCHITECT. USE ZONE ALLUAABLE INCREASE DUE TO REQUIRED PLANS PLOT PLAN 5. FOUNDATION DETAILS FOUNDATION PLAN 6. STRUCTURAL DETAILS FLOOR PLAN 7. ELEVATION PLANS GENERAL FRAMING 8.. kOF PLAN 9. iNDEX St4E- ¶10 THE, APPLICANT CORRECT PLANS WHERE CORRECTION LIST HAS BEEN CIRCLED. FLAG CORRECT I0NS.°() INCOMPLETE, INDEFINITE OR FADED DRAWINGS OR CLACULATIONS NOT ACCEPTABLE.' QC C. REQUIRED ENGINEER'S OR SURVEYOR'S k CALCULATIONS OR PLANS SHALL BE SIGNED IN INK. D. REVERSE PLANS MAY NOT BE USED. PROVIDE 4. CORRECT PLOT PLAN, FOUNDATION PLAN, IL FLOOR PLAN, AND ELEVATIONS. THE APPROVAL OF PLANS AND SPECIFICATIONS DOES NOT PERMIT THE VIOLATION OF ANY SECTION OF THE BUILDING CODE OR OTHER C]>Y, COUNTY OR STATE LAW. GENERAL () rSUBMITFULLY DIMENS IONED PLOT PLAN, DRATAN \_fr_• ¶10 SCALE, INCLUDING ALL EASEMENTS ON PROPERTY. 37,e r 13 +e t 5 2. SHOW ALL EXISTING AND PROPOSED BUILDINGS ON PLOT PLAN. 3. 'OW CORRECT LEGAL DESCRIPTION ON PLAN. SHOW ALL OFF. SITE IMPIOVEMENTS, DRIVE- WAY APPIOACH, LIGHT STANDARDS, FIRE HYDRANTS, WATER METERS, SUB-STRUCTURES, TREES, ETC. 5 • . RREC.1' LOT DIMENSIONS. SHOW EXISTING AND FINISH CONTOUR LINES. 7. SURVEY OF LOT REQUiRED. S e. INDICATE DICATE ALL GRADING '10 BE LONE. ELEVATIONS OF GARAGE FLOOR, AND STREET AND DRIVEWAY. 10. NDIC/\TE CENIERLINE AND EDGE PROFILE JOF DRIVEWAY. )~ SLOPE OF DRIVEWAY NOT ¶10 EXCEED 20%. (3d) INDICATE FL( LINES FOR pISPOSAL OF SURFACE WATER. Oo,,4 P4FY `0' ).3. LA Cc5STA A)RRL REQUIRED. S.D.C. HEILRI.INEPT. APPROVAL.REQ. . - 13a Show all REQUIREMENTS FOR HANDICAPPED. UBC Sec. 1711. CARRY WATER FROM UNDER SIDEWALK TH1UGH CURB INTO STREET WITH CAST IRON PIPE. PROVIDE ENGINEERING CALCULATIONS FOR / PROVIDE SOILS ENGINEER'S REPORT GRADING PERMIT REQUIRED., S FIRE DEPT. APPROVAL REQUIRED. SPECIFY CONCRETE MIX @ 2000 P.S.I. MINIMUM. DIMENSION FOOTING SIZES AND CLEARANCE FROM GRADE. S SHOW DEPTH OF FOOTINGS BEIA1 NATURAL OR UNDISTURBED GRADE. INDICATE PRESSURE TREATED FOUNDATION SILL, OR EQUAL. SHOW FOUNDATION BOLT SIZE, SPACING AND PENETRATION INTO CONCRETE. 17 "'F''$ /fMbNY INDICATE CLEARANCE FROM GRADE TO BOTTOM OF FLOOR JOISTS AND GIRDERS. 25; SHOW PIER SIZE, SPACING AND DEVH, fNIO • UNDISTURBED SOIL. S 26. SHOW GIRDER SIZE, SPACING AND DIRECION. 27.. . •: • . . S •: C SPECIFY MINIMUM 18"X24" ACCESS OPENING • • • ••••. •.. -. . •; .. SPECIFY UNDEPELOOR VENTILATION EQUAL TO 2 SQUARE FEET FOR EACH 25 LINEAL FEET OF FOUNDATION PLUS ONE OPENING WITHIN 3' OF EACH CORNER. STEP FCOTINGS WHEN SLOPE EXCEEDS 1:10. FRAMING PrcwIbE TYPICAL FRAMING DETAILS. S -. SPECIFY FRAMING LUMBER: GRADES . SPECIFY FIRE BLOCKING AT FLOOR, CEILING COVE AND MIDI[EIGUT OF WALLS OVER 10 FEET IN liT. ShOW DIAGONAL BRACING AT EACH CORNER AND EVERY 25 LINEAL FEET OF WALL. • S • . CLARIFY I3FQ\CING OF • WALL. 5110W SIZE, DIREC].ION AND SPACING OF FLOOR AND CEILINGS JOISTS. JOIS'IS P IN • • ARE OVERSPANNED. DOUu1E FTDOR JOISTS OR BEAM I. 1NDIR PAl ALTd1.. p/\RrJ:TSONS 40. sri:ciiv i n:Al)l:I ; i.zi: I)R ol:'l;N l:N(L; ovir 4 1 . '• rx.,:)rJfu ,: Lll:/\I)i:l.; ON 1:!)c:. • 729 - CLiI INç, jj') Cr1'!' S1194 U\TEV\L CNJSS BRACING AT GARAGE PrNv' LINE. 74. SnOW BEDROOM WINDOW AS EXIT, SECTION 1304. ELEVATIONS WrINDIQ½TE ATTIC VENTILATION PER SECTiON 3205 (c). SI'JOW ALL EAVE OVERHANGS AND CONSTRUCTION' 77. DIMENSION CHIMNEY I'EIGI-T ABOVE ROOF. (2' 0" ABOVE iX)F WITI-]IN'lO'O"). INDICATE FINISH AND NATURAL GRADE TO PROPERTY LINE. SHOW EXTERIOR WAIL FINISHES. INDICATE 15# FELT OR EQUAL ON EXTERIOR WALLS. TNU1TICILNf BEAM SIZE AT P1W1DE WU'JER TIES WlIIRE CEILING JOISTS AND RAFTE,'RS ARE NJD PARALLEL. E RAMTER SIZE, SPAN, SPACING DI RECrION. (j) fiow PURLINS ON EDGE' AND INDICATE /SIZE. 5n11is'6 j FT1f ,v(1V'. ((4) BRACE IX)F FRAMING TO PARTITIONS. INDICATE SOLID SHEATHING AND 2x6 OR 3x4 STUDS ON FIRST FLOOR OF THREES S'IO1' CONSTRUCTION.; SHOW SECTION THROUGH SHOW PLANTER BOX DETAILS AND WATER• PROOFING, SEC. 2517 C7., w U6 PROVIDE TYPICAL CHIMNEY DETAILS. SPECIFY 2' MINIMUM CLEARANCE BETWEEN CHIMNEY AND FRAMING. SPEC( POST PROTECTION WHEN BEABI ON CONCRETE. PROVIDE PARAPET DETAILS. J(NGPE ROOF PITCH. INDICATE ROOFING MATERIAL LENGTH & WEATHER / EXPOSURE ON )D SHINGLES. 33. SHOW TYPE, SIZE AND SPACING OF IX)F SHEATHING. 84. FIRE RETARDANT IX)F REQUIRED DUE 10 LOCATION IN ' FIRE ZONE. GARAGES 56. SPECIFY INSPECTION CLASS REQUIRED FOR 58.'iIOVIDE DRIP SCREED 2&t BELOW MUD SILL. 59. INDICATE HOW REQUIRED STRUCTURAL AND FIRE-RESISTIVE INTEGRITY WILL BE MAINTAINED. WHERE PENETRATION WILL BE MADE FOR ELECTRICAL, MECHANICAL, PLUMBING AND COMMUNICATIONS CONDUITS,.' PIPES AND SIMILAR SYSTEMS. SECTION 301 D. , CLARIFY DIMENSIONS AT_______________ SHOW WINDOW TYPE, SIZES AND LOCATIONS. - 62. LIGHT AND /OR VENTILATION INADEQUATE IN 'O/lO floor area -iO square feet mm. except bathroom). 63. .PROVIDE ' VERTICAL CLEARANCE AND HORIZONTAL CLEARANCE FROM RANGE TOP 10 COMBUSTIBLES., 64.,r-INDICATE ATTIC SCUTTLE- (22"x30" MIN.) PROVIDE DRAFT SEPARATION FOR ATTIC AREA 'IN EXCESS OF 2500 SQ. Fr. SEPARATE AREA ]3EIWEEN DROPPED CEILING AND FLOOR-ABOVE 10 1000 SQ.Fr. MAX. SPECIFY STALL SHOWER MIN.. WIIYTH .30" MINIMUM FLOOR AREA 900 SQ. INCHES. 68' SPECIFY WAIL FINISH IN SHOWER AREA NOT TO BE ADVERSELY AFFECIED BY MOISTURE 10 6' ABOVE THE FLOOR, AND PROVIDE SI'INrrEPPROOF DOORS. .69. WATER CLOSET AREA MINIMUM WIDTH 10 BE 30". . . • OPENINGS CLOSER THAN ¶ft3 :I)J)p1?'y LINE SILALL BE' OF HOUR' d3NSTRUC1hI0N. GARAGES NOT PERMITTED 10 OPEN INTO SLEEPING ROOM. PROVIDE SEPARATION ON ALL WAILS AND CEILINGS ADJACENT TO LIVING QUARTERS.- SPECIFY COOR,47INEOW OPENING FWM GAPAGE,/CARPORT STAIRWAYS' AND EXITS 90. PROVIDE HANDRAILS AS REQUIRED IN SECTION 3,305 (i).. PROVIDE , HOUR WALLS FOR 'STAIR'. WELL. INDICATE ' MAXIMUM RISE'. AND MINIMUM RUN ON STAIR. PROVIDE BALCONY RAILING AT 42 MINIMUM HEIGHT. • 'PROVIDE INTERMEDIATE RAILS @ 9" O.C. OR , EQUIVALENT FOR OPEN' TYPE BALCONY & STAIR RAILS. 97.' INDICATE' 6' 6" MINIMUM IIET\DROOM CLEARANCE,.. r ABOVE , ' STAIRWAY. . SHOW STAIRWAY CONSTRUCTION DETAILS. • SHOW FIXED WINDOW IN rXX)PS BETWEEN CARPORT AND LIVING QUARTERS.' ' OCCUPANT LOAD OF REQUIRES . '.. EXITS FROM • , • .. PROVIDE LIGhTS OVER STMrAYS AND P1JBLIC CORRIDORS..*•. SHOW CHANGE IN I'LOC,R LEVFL AT .DO'OS", 1" MAX. 'Sec.. 3303h. . • 102a SHOW HANDRAII. EXTENDING' 6" BEYOND THE TOP & BOTTOM RISERS '& TERMINA- TING IN A POST OR SAF.ETY1 TERMINAL Sec. 3305(i).,' PLUMBING S.... MISCrLTJ'SN! X)US I ri:'iis 1.01. N6iCATE lOCATION OF WATER inmn. BORED HOLES AND N(YI'CI!INC,, S1I01 DEI'ILS DJ TEMPERATURE AND PRESSURE RELIEF AS PER SECTION 251.8, (f) 10, 11. VALVES ON WATER IIE1\TERS WITH DISCHARGE LINES TO OUTSIDE. SEC. 1007. . SHOW TOTAL SQ. FT. OF AL GLASS 105. WATER HEATER NOT r BE LOCATED IN. IN BUILDING. 4,i o CLOSET, BEDROOM OR UNDER STAIRWAY 106, PROVIDE . . SQUARE INCHES . . Or- VL NTILATION AT TOP AND BOTTOM OF WATER HEATER. oe 108 S '6N 1007 . (b). .'. .. INDICATE MATERIAL TO BE USED AND 3 .H INSULATION REQUIREMENTS: lOCATION OF SEVER LINE. (IF V.C.P. ,,. . (.9 insulation in ceilings USE FLEXIBLE COMPRESSION JOINTS . (k'. . I rONLY) SHOW TWO WAY 0 IN YARD BOX \ bIT )-Show 4" insulation in walls (R-11) WITHIN 5' ff Show exterior doors weatherstripe PROVIDE MINIMUM 100 AMP. SERVICE. . .. . .. . cqths REQUIRE 100 AMP. PANEL FOR EACH UNIT. H( METER & PANEL LOCATION. I FIRE WAINGS SYSTEM. SEC. 1310. (Show) MECHANICAL . . .. . 114. INDICATE FURNACE SIZE, LOCATIONS & . . . . REGISTERS AND RETURN AIR . (SIZE). 115. INDICATE HEATING EQUIPMENT. IN ACCORD- . CHECKED: /ANCE WITH CHAPTER 7 OF UNIFORM HOUSING 5 , Date.• -'7C)DE. .. . . S 1 6. SPECIFY HEATING, AIR-CONDITIONING AND VENTILATING EQUIPMENT. INSTALLA- • . . S .. TIONS TO COMPLY WITH THE UNIFORM S RECHECKED .. . MECHANICAL CODE. . . . . . Date A. .• E. DUCTS Rttv4J *'k. B. . S.. LOCATION 7. IADDER & LIGHT THE FOREGOING CORRECTIONS HAVE BEEN COMBUSTION AIR C. 'D. VENTING CALCS FOR MADE AND ARE UNDERSTOOD BY THE '. 5 ' .RDOYLOADS UNDERSIGNED: 117. INDICATE LOCATION & TYPE OF FIRE . . . . S ., •55 DAMPERS. S , Owner - Or His Authorized Agent '- Electric: 1975 N.E.C. Ground-Fault-protection required for outdoor and bathroom receptacles At least one receptical shall be installed ou.tdoorsf 210-25b. COrrect electric asshowh on floor plan. S. These plans comply with the.. Requirements of the California . . . . . . Noise Insulation Standards.' S S Sign ec----------- Date_• .. S , , . Title' '. 5 . 'S.., March l, 1976 Mr. Ray Green Building Department City of Carlsbad, Ca. 1200 ElmAve. Carlsbad, Ca. 9200 In Re, George Farr permits Z. - Dear Sir, In view of recent developements it becomes necessary for me to disassociate myself and my license from the Farr .. . . Project. I request that you remove.myname and my license number. from the building permits issued.to GeorgeFarr over my signature on March 26 1976. •• . S • • . . Thank you. . • • ••: .: • . .. S. H. Nye, eij4. Cont • S • • S • :. • . : S 1026 San Abefla 5...... .•• S .. Encihitas Ca. 92024 Ca. Lie. 27430 RECEIVED MR 231976 S • S • • 5•5 5• S S •S •• CITY OF: CARLsAb S 1 •• S S S 55 S S S S Building Department March 10, 1976 George Farr 2439 Savilla Way 0 Carlsbad, Ca. 9200 Dear Sir, In regard. to the construction of the two houses on your pro- perty in Rancho La Costa, specifically lot, #95 - La Costa South Unit i/i and 1t #329 - La Costa South, unit #4. As 0 you know my name and state contractor's license appears on the building permits for these houses. At the beginning of our association, you showed me an old 0 contractor's license and said that you had it on an inactive 0 basis and could renew it whenever you chose. Acting on this " ,0 information, I made no further investigation of your 'condition. I have since been informed that this is not the case.- I have 0 been informed that there -is a legal action pending against you 0 for contracting'without:a license and that the Contractors' •0 0 State License Board has an investigation pending. Had I known 0 0 'these facts 1 would not have signed on your projects as the • 0 contractor.. ' 0 0 , • , 0 • 0 0 In' view of' this situation, I cannot continue the construction 0, ' • • , or permit you to continue the , ',, construction of the • ' 0 above said houses until the following' terms and conditions are met. First, I must be informed as to the financial institution, if any, and their funding organization, method and times of 0 ' funding. 'If no financial institution is involved, it will be 0 , 'necessary to open a fund control with any approved funding ' 0 organization. An amount equal to the cost break downs must' be deposited in that fund control. Both your signature and ' mine will be required on any voucher drqwig monies from that fund control. 0 Further, I must have a list of all sub-contractors that you. ' ' , have, entered into'a contract with 9 their'names, addresses,'. ' telephone numbers, state license numbers, and' workmen's comp 0 carriers. All sub-contractors must have my approval. 0 Since the above will require more of my time than I hadl ori- ginally anticipated and since I was acting as your' General ' O ' • ' 0 Contractor without fee or compensation, any time spent on - George Farr, continued Page 2 March 101 1976 Inspections to protect the state, the City of Carlsbad, and/ or myself against any code violations will be charged to you At a hourly rate cominensorate with the standards of the industry. Further, it will be necessary for you to honor the sub-con- tracts you have already signed with me. Specially the pay- ment of the progress payment that is now due. Acceptance of these terms must be in writing and in my office by March 15, 1976, or.it will be necessary for me to with- .;• • - draw my license and authorization from the forernentioned : projects. Respectfully, S. H. Nye, General Contractor 1026 San Abella • Encinitas, Ca. 92024 Phone 753-9907 State Lic. #27430 cc City of Carlsbad Calif. St. Lic.-BOard •. • • • • G. Robert Grosz, Att.