HomeMy WebLinkAbout264 CARLSBAD VILLAGE DR; ; CB993666; Permit11/01/1999
City of Carlsbad
Commercial/Industrial Permit Permit No
Building Inspection Request Line (760) 438-3101
CB993666
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
Project Title
264 CARLSBAD VILLAGE DR CBAD
Tl Sub Type
2032321600 Lot#
$176,982 00 Construction Type
28 Reference #
TIBERIUS ANTRO
RESTAURANT Tl 4534 SF-INTER &KIT REMOD
COMM
0
NEW
Applicant
CALABRESE MAURIZIO
1569PRIMAVERA
OCEANSIDECA 92056
760-213-0208
Status
Applied
Entered By
Plan Approved
Issued
Inspect Area
Owner
JRURIANQJ3AMIANO&SANTA
264CARLSBAD,VILLAGEDR711
CARLSBAD VILLAGE DR *
ISSUED
10/05/1999
JM
11/01/1999
11/01/1999
0001 01 02
1091-75
Total Fees $1,67063 Payments'BalanceDue $1,091 75
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
$890 58
$000
$578-88
$oq
$37-177
$0/00
$(H)0
$000$o'bo
$000
$000
rPFFT'{CFD Fund)
^License Tax^_ \ ^
License-Tax^GFD Fund)
Traffic Impact Fxee * */
Trafficclrnpa3r(CFDxFund)
LF-IV]Z\Transportation Fee
PLyMBING-TOTAL
EtlECTRICAL TOTAL
MECHANICAL TOTAL
Master Drainage Fee
Sewer Fee
Redev Parking Fee
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$9000
$2000
$5400
$000
$000
$000
$1,67063
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the "Imposition of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and arty oiher required information with trie City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy
changes nor planning, zoning, grading or other similar application processing or service fees in connecfran wfri this project NOR DOES IT APPLY to any
fees/exactions of which you have previouslyjeen given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad, CA 92009 (760) 438-1161
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
2075 Las Palmas Dr, Carlsbad CA 92009
(760)438-1161
FOR OFFICE USE ONJ
PLAN CHECK NO
EST VAL
Date
Address (include Bldg/Suite #)Business Name (at this address)
yt..
Leal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units
Assessor's Parcel #Existing Use Proposed Use
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to Me a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law
IChapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code! or that he is exempt therefrom, and the basis for the alleged
exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [5500]}
Name
State License #
Address
License Class
iQlt
City State/Zip
City Business License #
Telephone #
Designer Name
State License # C
Address Citv
&&&}„—1.
ifi!
I V '1 , I C ! i ~ i" ' i ' M j -I-^^LIi i-t.nB-'-^kiji»J»miJ£.n-il-ifc. • "..^-.^--^..^M^—^ravti;.-,.. i»i>JtH> -Hi^*ti»iai"'«*UW«* J-,-
Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations
d I have and will maintain a certificate of consent to self-insure for workers compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued
Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued My worker's compensation insurance earner and policy number are
Insurance Company Policy No Expiration Date
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS l$100] OR LESS)
Sj CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers Compensation Laws of California
WARNING Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100,000) in addition to the cost of compensation, damages as provided for m Section 3706 of the Labor code, interest and attorney s feesS —•^=f~&3^r £> ~~
SIGNATURE ^fifi^ p cT^-^yV.^^^ fo DATE
^^OWNER-BUILDER DECLARATION'^^ ZltL'."" ""' *" """
1 hereby affirm that I am exempt ftom the Contractor's License Law for the following reason
Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec 7044, Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale If however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale)
Of I. as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The
"Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law)
d I am exempt under Section Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement Q YES C)NO
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number)
4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number) n __
5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work) ,
PROPERTY OWNER SIGNATURE DATE - or-A?
[COM^L^f Ei^HIS fSECf fbRFOR>0«^^
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES Q NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' Q YES D NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES Q NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
i-^L4!-!L.h!,- S-JL^-I^Li jLLa-uJ£feLl~^iJ^—«kCibaj.~"..Ju.LL J^lii. J^il
-'ji ...... .M ........ if— n- ..... >i—f" ....... T-" r~~ -~ i-
hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code)
LENDER'S NAME LENDER'S ADDRESS
•;, ~ir?m«H*j«jni'!i|-r t-™™Er—?™> m™ i^rr-"1™! p'STll, '• •, '7W *!* "'Tfl&la 7! 8!!Ps HT^P T! l!$!"f'" '1' WW \?M I ?> "WfFP'i"! DriP! * W111' !fl?f(Frf 'IfWT^'t. ,„.... „ <LJkl^U4u4L&i*^*wU.udi .*»-.U~BJu:iLwt,l.HrfhjjJ«^l*-»*~»i.-iSf^w^! !••**-« - «"U~.:.L -, v^f J^»LUi-^i-"~.£>uu.ii6nWwt«w-iuj^.«y"U.i,L^L^aiL"SjM,'u „!
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all
City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height
EXPIRATION Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or
work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended
or abandoned at any time after the work is commenced for_a period of 180 days (Section 10644 Uniform Building Code)
APPLICANT'S SIGNATURE DATE
WHITE pile YELLOW Applicant PINK Finance
City of Carlsbad Inspection Request
For 12/29/1999
Permit# CB993666
Title TIBERIUS ANTRO
Description RESTAURANT Tl 4534 SF-INTER &KIT REMOD
Inspector Assignment SR
264 CARLSBAD VILLAGE DR
Lot 0
Type Tl
Job Address
Suite
Location
APPLICANT CALABRESE MAURIZIO
Owner DINITTO PROPERTIES INC
Remarks
Sub Type COMM
Phone
Inspector
Total Time
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Requested By MAURICE
Entered By CHRISTINE
Act Comments
Associated PCRs
Inspection History
Date Description Act Insp Comments
12/27/1999 89 Final Combo
12/3/1999 15Roof/Reroof
12/3/1999 44 Rough/Ducts/Dampers
12/1/1999 44 Rough/Ducts/Dampers
11/30/1999 44 Rough/Ducts/Dampers
11/22/1999 14Frame/Steel/Bolting/Welding
11/22/1999 23 Gas/Test/Re pairs
11/22/1999 44 Rough/Ducts/Dampers
11/22/1999 45 Hoods
11/17/1999 21 Underground/Under Floor
11/17/1999 23 Gas/Test/Re pairs
CO TP SEE NOTICE ATTACHED
AP SR
AP SR
CO SR NEEDS WELDS ON VENTS ON THE ROOF (NEEDS GUTTERS)
CA SR NOT READY
AP SR INSIDE NO BEARING WALLS
AP SR
AP SR
AP SR
NR SR
NR SR
EsGil Corporation
In Tartnerskip witfi government for
DATE October 29, 1999 O^EEUANT
JURISDICTION Carlsbad Q PLAN REVIEWER
a FILE
PLAN CHECK NO 99-3666 SET II
PROJECT ADDRESS 264-Carlsbad Village Drive
PROJECT NAME Kitchen Remodel for Antro Ristorante Italiano
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
X] The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) Fax #
Mail Telephone Fax In Person
X REMARKS' See attached PME correction This is being hand carried by Maurizio
By Bert Domingo Enclosures
Esgil Corporation
D GA n MB D EJ D PC Log trnsmtldot
9320 Chesapeake Dave, Suite 208 4 San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576
The City must grant a waiver for^the permanent ladder required to service the
roof mounted equipment and agree to the use of a portable ladder (existing
method) of a permanent ladder must be added to the plans (See sheet A6 for
the amount of rooftop equipment)
EsGil Corporation
In fanner skip With government for 'BuiCd'ing Safety
DATE October 15, 1999 a APPLICANT
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 99-3666 SET I
PROJECT ADDRESS 264 Carlsbad Village Dr.
PROJECT NAME Kitchen Remodel for Antro Ristorante Italiano
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
X] The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
X) The applicant's copy of the check list has been sent to
Maurizio Calabrese
1567 Pnma Vera, Ocienside, CA 92056
XI Esgil Corporation staff did not advise the applicant(except by mail) that the plan check has
been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Maurizio Calabrese Telephone # (760) 213-0708
Date contacted (by ) Fax # (760) 630-3380
Mail Telephone Fax In Person
REMARKS
By Bert Domingo Enclosures
Esgil Corporation
• GA • MB Q EJ D PC 10/7/99 trnsmtldot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576
Carlsbad 99-3666
October 15, 1999
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO 99-3666
OCCUPANCY A3
TYPE OF CONSTRUCTION VN
ALLOWABLE FLOOR AREA
JURISDICTION Carlsbad
USE Restaurant
ACTUAL AREA 4538 SQ FT
STORIES ONE
DATE PLANS RECEIVED BY
ESGIL CORPORATION 10/7/99
PLAN REVIEWER Bert Domingo
HEIGHT
SPRINKLERS'? OCCUPANT LOAD
REMARKS
DATE PLANS RECEIVED BY
JURISDICTION
DATE INITIAL PLAN REVIEW
COMPLETED October 15, 1999
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled This plan review
is based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments Clearance from those departments may be required
prior to the issuance of a building permit
Code sections cited are based on the 1997 UBC
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law
To speed up the recheck process, please note on this list for a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot
Carlsbad 99-3666
October 15, 1999
A) Please make all corrections on the original tracings, as requested in the correction
list Submit three sets of plans for commercial/industrial projects (two sets of plans for
residential projects) For expeditious processing, corrected sets can be submitted in one
of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (760) 438-
1161 The City will route the plans to EsGil Corporation and the Carlsbad Planning,
Engineering and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by EsGil Corporation is
complete
1 Each sheet of the plans must be signed by the person responsible for their
preparation, even though there are no structural changes Business and
Professions Code
2 Provide a statement on the Title Sheet of the plans that this project shall comply
with Title 24 and the 1997 UBC, UMC and UPC and 1996 NEC
3 Provide a section view of all new interior partitions Show
a) Type, size and spacing of studs Indicate gauge for metal studs Specify
manufacturer and approval number or indicate "to be ICBO approved"
b) Method of attaching top and bottom plates to structure (NOTE Top of
partition must be secured to roof or floor framing, unless suspended
ceiling has been designed for partition lateral load)
c) Wall sheathing material and details of attachment (size and spacing of
fasteners)
d) Show height of partition and suspended ceiling, and height from floor to
roof framing or floor framing
4 Note on the plans "All interior finishes must comply with Chapter 8 of the UBC"
Specify "Class flame spread rating (minimum) for
5 Specify lever-type hardware for passage doors on floors accessible to the
disabled Title 24
Carlsbad 99-3666
October 15, 1999
• ELECTRICAL
6 Submit plan showing location of all panels
7 Submit panels schedules
8 Submit electrical load calculations
9 Indicate existing main service size
10 Indicate existing total main service load
11 Indicate new additional loads
12 Indicate wiring method, i e EMT, metal flex
• REMODELS. ADDITIONS AND REPAIRSfHandicapped Requirement)
DOORS
1 Show or note that all hand-activated door opening hardware meets the following
requirements, per Section 1133B 251
a) Is to be centered >30" but <44" above floor
b) Latching, or locking, doors in a path of travel are operated with a single
effort by
i) Lever type hardware
n) Panic bars
MI) Push-pull activating bars
iv) Or other hardware designed to provide passage without the
requirement to grasp the hardware
2 Show or note that the lower 10" of all doors comply with Section 1133B 2 6, as
follows
a) To be smooth and uninterrupted, to allow the door to be opened by a
wheelchair footrest, without creating a trap or hazardous condition
b) Narrow frame doors may use a 10" high smooth panel on the push side of
the door
Carlsbad 99-3666
October 15, 1999
* PLUMBING, MECHANICAL AND ENERGY CORRECTIONS
* JURISDICTION: Carlsbad DATE: 10/15/99
4 PLAN REVIEW NUMBER: 99-3666 SET: I
4 PLAN REVIEWER: Glen Adamek
1 The licensed designer must sign each sheet of the plans
2 The City Building Official to review evidence of Health Department approval (for
restaurants)
• PLUMBING (1997 UNIFORM PLUMBING CODE)
3 Provide the site plumbing plans showing the sizes and locations of the gas
meters and water meter, and the sizes, routes, and slopes of the building sewer,
site gas lines, and site water lines
4 As per UPC, Section 1014 1, provide a grease trap or grease interceptor to
protect the sewer from the waste from the janitor's sink or mop sink and required
kitchen floor drains
5 Show the required floor drains in the commercial kitchen, as per UPC, Section
41222
6 Detail the required listed reduced pressure principle backflow preventer as
protection of water connection to carbonator UPC, Section 603 4 13
7 Pot sinks, scullery sinks, dishwashing sinks silverware sinks, dishwashing
machines, silverware-washing machines and other similar fixtures shall be
connected directly to the drainage system A floor drain shall be provided
adjacent to the fixture, and the fixture shall be connected on the sewer side of
the floor dram trap, provide that no other drainage line is connected between the
floor dram waste connection and the fixture dram The fixture and floor dram
shall be trapped and vented as required by this Code UPC, Section 704 3
Please correct the plans.
8 No vent from an indirect waste piping shall combine with any sewer connected
vent, but shall extend separately to the outside air Correct the lavatory vents.
UPC Section 803 0
Carlsbad 99-3666
October 15, 1999
• MECHANICAL (1997 UNIFORM MECHANICAL CODE)
9 Provide mechanical plans showing existing and proposed HVAC equipment,
ducts and access to equipment
10 Show the size, location and type of all heating and cooling appliances or
systems
11 Provide mechanical ventilation in all rooms capable of supplying outside air at a
minimum rate of 15 cubic feet per minute per occupant UBC, Section 1202 2 1
12 Provide complete kitchen hood plans, details, and calculations to show
compliance with UMC, Chapter 5, Part II
a) Provide roof framing around new openings in the roof for the exhaust and
make-up air ducts for kitchen hoods
b) Provide exhaust sizing calculations for kitchen hoods UMC, Section
5087
c) Provide grease duct air velocity calculations Minimum 1,500 fpm and
maximum 2,500 fpm UMC, Section 507.8
d) Provide construction details of required fire rated grease duct enclosure
and hood enclosure UMC, Sections 507 6, and 508 4 1
e) Detail the kitchen hood exhaust duct discharge clearances as per UMC,
Section 507 11
f) The fire-rated grease duct and/or hood enclosures must extend from the
point of penetration of the ceiling up to the roofing The ceiling or hood
enclosure must be over the hood UMC, Sections 507 6, 508 4, and
50841
g) The fire-rated grease duct enclosures must be sealed around the duct at
the point of penetration of the ceiling UMC, Section 507 6
h) Show required cleanouts for grease duct on hood UMC, Section 507 5
i) Detail 1/4 inch per foot slope on grease duct back to hood UMC, Section
5074
j) and make-up air systems shall be connected by an electrical interlocking
switch UMC, Section 402 4
k) Clearly show the material used to construct the hood and exhaust duct
UMC, Sections 508 2 & 507 3
I) An exhaust outlet within the hood shall be so located as to optimize the
capture of particulate mater Each outlet shall serve not more than 12 foot
section of hood UMC, Section 508 9
Carlsbad 99-3666
October 15, 1999
m) Provide the required clearances from unprotected combustible
construction of at least 18 inches, as per UMC, Section 507 10
n) A complete kitchen hood system plan review will be done when the
complete hood system plans, details, and calculations are provided
13 Provide the listing data and installation data for the proposed wood burning pizza
oven If not listed a third party installation report will be required for the approval
of the construction and installation of the proposed wood burning pizza oven to
approved standards UMC, Section 302 2
14 Detail the flue (vent) terminations as per UMC, Section 806
15 Detail the flue (vent) offsets, length, pitch and clearances as per UMC, Section
805
16 Show the location of the required roof access ladder to roof mounted HVAC
equipment UMC, Section 307 5
17 Detail disposal sites of mam condensate drainage from air conditioning units
UMC Section 309
18 Provide smoke detection in supply air duct of 'air-moving system' for required
shut-off for smoke control as per UMC, Section 608 and also see Section 203
. ENERGY CONSERVATION
19 As of July 1, 1999 the new 1998 Energy Standards must be used Not the 1995
Energy Standards
20 Provide complete energy designs for the proposed changes in envelope, lighting,
and mechanical systems Provide the completed ENV-1, ENV-2, ENV-3, LTG-1,
LTG-2, MECH-1, MECH-2, MECH-3, and MECH-4 forms showing energy
compliance
21 On the plans clearly show the wall and roof insulation locations, thickness, and
R-values, as per the energy design
22 Show the daylit areas and required dayht area lighting controls for new or
relocated lighting tn daylit areas Title 24, Part 6, Section 131(c)
23 Showbi-leve! lighting controls as per Title 24, Part 6, Section 131(b)
Carlsbad 99-3666
October 15, 1999
24 The completed and signed ENV-1, LTG-1, and MECH-1 forms must be imprinted
on the plans
25 The Documentation Author and the Principal Envelope Designer must sign the
ENV-1 form
26 The Documentation Author and the Principal Lighting Designer must sign the
LTG-1 form
27 The Documentation Author and the Principal Mechanical Designer must sign the
MECH-1 form
28 Complete energy plan check will be done when complete corrected energy
designs are provided
Note: If you have any questions regarding this plumbing, mechanical and energy plan
review list please contact Glen Adamek at (858) 560-1468 To speed the review
process, note on this list (or a copy) where the corrected items have been
addressed on the plans
• MISCELLANEOUS
13 Where is the door # 5 on the schedule
14 It seems that the handicapped sign is at the parking area is blocking the
unloading aisle
15 Please show the height of the barricade at the patio to the parking area
Carlsbad 99-3666
October 15, 1999
To speed up the review process, note on this list (or a copy) where each correction item
has been addressed, i e , plan sheet, note or detail number, calculation page, etc
Please indicate here if any changes have been made to the plans that are not a result
of corrections from this list If there are other changes, please briefly describe them and
where they are located in the plans
Have changes been made to the plans not resulting from this correction list? Please
indicate
Yes Q No Q
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to
perform the plan review for your project If you have any questions regarding these plan
review items, please contact Bert Domingo at Esgil Corporation Thank you
Carlsbad 99-3666
October 15, 1999
VALUATION AND PLAN CHECK FEE
JURISDICTION Carlsbad PLAN CHECK NO 99-3666
PREPARED BY Bert Domingo DATE October 15, 1999
BUILDING ADDRESS 264 Carlsbad Village Dr.
BUILDING OCCUPANCY A3 TYPE OF CONSTRUCTION VN
BUILDING PORTION
Air Conditioning
Fire Sprinklers
TOTAL VALUE
BUILDING AREA
(ft2)
VALUATION
MULTIPLIER
VALUE
($)
$ 176,98200
•1994 UBC Building Permit Fee n Bldg Permit Fee by ordinance $ 89058
• 1994 UBC Plan Check Fee n Plan Check Fee by ordinance $ 57887
Type of Review • Complete Review Q Structural Only Q Hourly
[] Repetitive Fee Applicable Q Other
Esgil Plan Review Fee $ 463 10
Comments
Sheet 1 of 1
macvalue doc 5196
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB
ADDRESS
DATE /o
/5.6 V /^xLS-4^^ /A/7/f Q*\ o £)f~
RESIDENTIAL TENANT IMPROVEMENT
RESIDENTIAL ADDITION MINOR
(< $1OtOOO.OOl
OTHER
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
PLANNER DATE
ENGINEER DATE
OCTOBER 7, 1999
TO BUILDING DEPARTMENT
FROM Management Analyst, Redevelopment Department
PROPOSED TENANT IMPROVEMENTS FOR EXISTING RESTAURANT
LOCATED AT 264 CARLSBAD VILLAGE DR. - TIBERIUS ANTRO RISTORANTE
ITALIANO - PLAN CHECK NO. 993666
I have reviewed the building plans for the above referenced project I do not have
any objections to the issuance of the building permit for this project This information
has been entered into Permits Plus If you have any questions, please contact me at
x2813
LORI H. ROSENSTEIN
2 ( o
O
E
O 01 01Q. OT
O O
,,
I I I I -- I I (» I * I(Bcoo)aic)oicnc»Q.o->ooi--a a. o~d a. a. a. a<o n OT,. n a?c»n n a." ° a. a.
PACIFIC OCEAN
O
0
SITTO, ARCHITECT
EW MORNING RD
CA 91941
)) 670-1559 FAX (619)
HATRA BILL KACHI. CML hS6
1010 SINGING RIDGE"
EL CAJON, CA. 92019
TEL/FAX(6l9)440-6533