Loading...
HomeMy WebLinkAbout2641 GATEWAY RD; 102; CB110683; Permit06-03-2011 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB110683 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 2641 GATEWAY RD CBAD St: 102 Tl Sub Type 2131912500 Lot#: $108,756.84 Construction Type Reference # ELEVATION BURGER: 1861 SF VANILLA SHELL TO RESTAURANT COMM 0 5B Applicant: RAY GABLE 158 WEST MAI NST LENA 61048 815-369-9155x108 Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Plan Check*: Owner: LNR Cf>J BRESSI RETAIL L L C C/0 LNg PROPERTY CORP 4350 VON KARMAN AVE #200 NEWPORT BEACH CA 92660 ISSUED 03/31/2011 JMA 06/03/2011 06/03/2011 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD#2Fee BTD#3Fee Renewal Fee Add'l Renewal Fee Other Building Fee ' Pot. Water Con. Fee; Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Fire Expedited Plan Review $678.69 $0.00 $441.15 $0.00 $0.00 $22.84 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $4.00 $520.00 Meter Size Add'l Reel. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF (31 05540) PFf (4305540) Liefense Tax (3 1 041 93) License Tax (43041 93) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees HMP Fee $0.00 $0.00 $0.00 $0.00 $1,979.37 $0.00 $0.00 $0.00 $0.00 $0.00 $209.00 $220.00 $72.00 $0.00 $0.00 $0.00 $0.00 ?? TOTAL PERMIT FEES $4,147.05 Total Fees:$4,147.05 Total Payments To Date:$4,147.05 Balance Due:$0.00 L Inspector: FINAL APPROVAL Date: f" *~ «Clearance: NOTICE; Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. 08-03-2011 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Storm Water Pollution Prevention Plan (SWPPP) Permit Permit No:SW110268 Job Address: Permit Type: Parcel No: Reference #: CB#: Project Title: Priority: Applicant: GARY STEBBINGS 160 DRY CREEK RD SEDONA AZ 86336 928-301-8838 Emergency Contact: GARY STEBBINGS 2641 GATEWAY RD CBAD SWPPP 2131912500 PCR11085 Lot#: ELEVATION BURGER CHANGES IN PLUMBING (RELOCATE GREASE L Status: ISSUED Applied: 06/28/2011 Entered By: LO Issued: 07/07/2011 Inspect Area: TP Tier: 1 Owner: LNR CPI BRESSI RETAIL L L C C/O LNR PROPERTY CORP 4350 VON KARMAN AVE #200 NEWPORT BEACH CA 92660 928-301-8838 SWPPP Plan Check SWPPP Inspections Additional Fees $45.00 $54.00 $0.00 TOTAL PERMIT FEES $99.00 Total Fees:$99.00 Total Payments To Date:$99.00 Balance Due:$0.00 «t Ny" CITY OF CARLSBAD JOB ADDRESS 2641 CT/PROJECT* LOT* Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717/2718/2719 Fax 760-602-8558 www.carlsbadca.gov Gateway Rd PHASE # # OF UNITS # BEDROOMS Plan Check No. C--O // 0(0 £3 Est. Value */{)$- 1 Plan Ck. Deposit ' Date SUITE#/SPACE#/UNIT# APN Suite 102 213 - 191 # BATHROOMS TENANT BUSINESS NAME Elevation Burger S^,<P</ SWPPP -25-00 CONSTR. TYPE OCC. GROUP 5N A2 DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) Tenant build out of an existing 1 861 s.f. vanilla shell. EXISTING USE PR No previous use CONTACT NAME (If Different Font Applicant) OPOSED USE GARAGE (SF) A2 n/a ADDRESS CITY PHONE EMAIL - STATE ZIP FAX ^nM^r, ^ <?/w PROPERTY OWNER NAME .....—.»..» ~ . . „ , .LNR CPI Bressi, Inc. , Seelye Arms ADDRESS 4350 Von Karman Ave, Suite 200 CITY New Port Beach PHONE 949-885-8500 STATE ZIP CA 92660 FAX n/a EMAIL sarms@lnrproperty.com ARCH/DESIGNER NAME & ADDRESS n/a STATE LIC. # n/a PATIOS (SF) DECKS (SF n/a APPLICANT NAME ADDRESS ) FIREPLACE AIR CONDITIC Ray Gable NING FIRE SPRINKLERS O|~n YES[7] N0| | 158 West Main Street CITY STATE ZIP Lena IL 61048 PHONE FAX 81 5-369-91 55 x 1 08 81 5-369-4495 EMAIL CONTRACTOR BUS. NAM raygable@lingledesign.com fM&ntiez- C0M&7BD .«K~. ADDRESS , \ ' IbG DAY C^e&fiL ft&fa) CITY PHONE STATED ZIP /r2~ < FAX 'S£Y EMAIL _/ // ^ / / JL STATE LIC.# •x'' CLASS CITY BU 8 & ?<^ C-.^A*. S. LIC.# ^—.—-/t^>7ST^ (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires theapplicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to acivil penalty of not more than five hundred dollars ($500)). Wo* ICE" if r Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations: LJ I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. By1 have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for whictthispermit is issued. My workers' compensation Jnsurance carrier and policy number are: Insurance Co ^{Jf(£t4' . Policy No. \jfl £ft S"feQ °l O I Expiration Date I \ '2^ This section need not be completed if the permit is for one hundred dollars ($100) or less. I | Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, cwades as provided for in Section 3706 of the Labor code, interest and attorney's fees. I hereby affirm that I am exempt from Contractor's License Law for the following reason: | | I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I | I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). | I I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. I lYes I [No 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): ^PROPERTY OWNER SIGNATURE QAGENT DATE COMPLETE THIS SECTION FOR N O N - R E S I 0 E N T I A L BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? I I Yes I / iNo Is the applicant or future building occupant required to obtain a permit from the air pollution control district or airouality management district? I htes 171 No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? FlYes [TlNo IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPAN EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONS T R UCT I O N t E N DING A G E N C Y I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address A'P P LIC ANT I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHft An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). ^APPLICANT'S SIGNATURE ^L^s&.J^- DATE 03/24/11 City of Carlsbad Bldg Inspection Request For: 08/05/2011 Permit* CB110683 Title: ELEVATION BURGER: 1861 SF Description: VANILLA SHELL TO RESTAURANT Inspector Assignment: TP 2641 GATEWAY RD 102 Lot: Type:TI Job Address: Suite: Location: APPLICANT RAY GABLE Owner: Remarks: recheck on the plumbing Sub Type: COMM Phone: 9282021257 Inspector; Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By: MIKE Entered By: CHRISTINE Act „ Comments Comments/Notices/Holds Associated PCRs/CVs/SWPPPs Original PC# PCR11085 ISSUED ELEVATION BURGER: RELOCATE; GREASE INTERCEPTOR/CORRECTION IN ELECT PCR11089 ISSUED , ELEVATION BURGER- REVISE; CEILING FROM EXPOSED TO T-BAR & ADD SOFFIT Inspection History Comments NOTICE ATTCH. OK TO USE FOR TRAINING TIE-IN TO G.I. GREASE DUCT FIRE WRAP PER REV. W/H DUCTSA/ENT ABOVE T-CLNG G I TANK INSTALLATION GREASE DUCT WRAP NOT PER SPECS G I TANK INSTALLATION T-CLNG KIT TO PLACE BORDER TILE GREASE DUCT FIRE WRAP SUPP, RET, MAKE UP FOR HOODS Date 08/03/201 1 08/01/2011 07/29/2011 07/29/2011 07/27/201 1 07/27/201 1 07/26/2011 07/25/2011 07/25/201 1 07/25/2011 07/25/201 1 07/25/2011 Description 89 Final Combo 21 Underground/Under Floor 44 Rough/Ducts/Dampers 44 Rough/Ducts/Dampers 22 Sewer/Water Service 44 Rough/Ducts/Dampers 22 Sewer/Water Service 14 Frame/Steel/Bolting/Welding 17 Interior Lath/Drywall 24 Rough/Topout 34 Rough Electric 44 Rough/Ducts/Dampers Act CO AP AP PA AP CO AP PA we PA CO PA Insp TP TP TP TP TP TP TP TP TP TP TP TP Inspection List Permit*: CB1 10683 Type: Tl Date Inspection Item 08/05/2011 89 08/05/2011 89 08/03/2011 89 08/03/2011 89 08/01/2011 21 08/01/2011 21 07/29/2011 44 07/29/201 1 44 07/29/201 1 44 07/27/2011 22 07/27/2011 44 07/26/2011 22 07/26/2011 22 07/25/2011 14 07/25/2011 17 07/25/2011 17 07/25/2011 24 07/25/2011 34 07/25/2011 44 07/25/2011 84 07/19/2011 301 07/19/2011 44 07/19/2011 84 07/05/2011 14 07/05/2011 34 07/05/2011 34 07/05/2011 39 06/27/2011 17 06/23/2011 14 06/23/2011 24 06/23/2011 34 06/23/201 1 44 06/22/201 1 24 06/22/2011 34 06/17/2011 11 06/15/2011 21 Final Combo Final Combo Final Combo Final Combo Underground/Under Floor Underground/Under Floor Rough/Ducts/Dampers Rough/Ducts/Dampers Rough/Ducts/Dampers Sewer/Water Service Rough/Ducts/Dampers Sewer/Water Service Sewer/Water Service Frame/Steel/Bolting/Weldin Interior Lath/Drywall Interior Lath/Drywall Rough/Topout Rough Electric Rough/Ducts/Dampers Rough Combo Overhead Hydro Rough/Ducts/Dampers Rough Combo Frame/Steel/Bolting/Weldin Rough Electric Rough Electric Final Electrical Interior Lath/Drywall Frame/Steel/Bolting/Weldin Rough/Topout Rough Electric Rough/Ducts/Dampers Rough/Topout Rough Electric Ftg/Foundation/Piers Underground/Under Floor COMM Inspector Act - PD - TP - TP TP - TP TP TP TP - TP TP - TP TP TP - DF TP TP TP TP TP TP TP MC MC MC MC TP TP TP TP Rl AP Rl CO Rl AP AP Rl PA AP CO AP Rl PA we Rl PA CO PA Rl CPLT AP AP AP AP AP we AP PA PA PA we CO CO AP PA ELEVATION BURGER: 1861 SF VANILLA SHELL TO RESTAURANT Comments recheck on the plumbing NOTICE ATTCH. OK TO USE FOR TRAINING AM PLEASE GREASE LINE TIE-IN TO G.I. GREASE DUCT FIRE WRAP PER REV. fire wrap banding W/H DUCTS/VENT ABOVE T-CLNG G I TANK INSTALLATION GREASE DUCT WRAP NOT PER SPECS G I TANK INSTALLATION GREASE INTERCEPTOR T-CLNG KIT TO PLACE BORDER TILE GREASE DUCT FIRE WRAP SUPP, RET, MAKE UP FOR HOODS GREASE DUCT OK TO FIRE WRAP (NEED C/0) T-CLNG DINNING AREA ONLY SOFFITS SOFFITS CONDUIT / FLEX @ SUB PNLS WALL FRAME ONLY, SEE CARD SEE CARD, WALLS ONLY SEE CARD, WALLS ONLY NO TEST SLAB POUR BACK @ TRENCHES U/G SAN/GS TEST, NEED ISO REV. 06/15/2011 24 Rough/Topout TP NR APPROVED VENTS NOT COMPLETE Friday, August 05, 2011 Page 1 of 1 City of Carlsbad Final Building Inspection Dept: Building Engineering Planning CMWD St Lite Fire Plan Check #: Permit*: Project Name: Address: Contact Person: Sewer Dist: inspected^ Inspected Bv: Inspected Bv: Comments: CB1 10683 ELEVATION BURGER: 1861 SF VANILLA SHELL TO RESTAURANT 2641 GATEWAY RD #102 MIKE Phone: 9282021257 CA Water Dist: CA vTW / Date */x In-^~>^ ^V Inspected: ^ ^ / 1 1 U Date Inspected: Date Inspected: Date: Permit Type: Sub Type: Lot: 0 Approved: (/ Approved: Approved: 08/03/2011 Tl COMM Disapproved: Disapproved: Disapproved: EsGil Corporation CANTr REVIEWER a FILE In tPartnersRip with government for (Building Safety DATE: 5/9/11 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 11-0683 SET: II PROJECT ADDRESS: 2641 Gateway Rd Suite 102 PROJECT NAME: Elevation Burger - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. I 1 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person REMARKS: Applicant to add notes in red on sheet A400 to By: Doug Moody Enclosures: EsGil Corporation eld sets. D GA EJ D PC 5/5/11 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 ^ (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In (Partnership with government for (Buitding Safety DATE: 4/8/11 a JURISDICTION: City of Carlsbad a FILE PLAN CHECK NO.: 11-0683 SET: I PROJECT ADDRESS: 2641 Gateway Rd Suite 102 PROJECT NAME: Elevation Burger - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. X] The applicant's copy of the check list has been sent to: Ray Gable 158 West Main Street, Lena, IL 61048 Esgil Corporation staff did not advise the applicant that the plan check has been completed. XI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Ray Gable Telephone #: 815-369-9155 ext. 108 Date contacted !7 /•/'/ (byZ^) Email: raygable@lingledesign.com Fax #: 815-369-4495 a\\^ Telephone Fax </* In Person REMARKS: By: Doug Moody Enclosures: EsGil Corporation D GA D EJ D PC 4/4/11 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 > (858) 560-1468 4 Fax (858) 560-1576 City of Carlsbad 4/8/11 11-0683 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 11-O683 OCCUPANCY: A2 TYPE OF CONSTRUCTION: VB ALLOWABLE FLOOR AREA: SPRINKLERS?: Yes REMARKS: DATE PLANS RECEIVED BY JURISDICTION: Unknown DATE INITIAL PLAN REVIEW COMPLETED: 4/8/11 JURISDICTION: City of Carlsbad USE: Restaurant ACTUAL AREA: 186.1sf STORIES: 1 HEIGHT: OCCUPANT LOAD: 64 DATE PLANS RECEIVED BY ESGIL CORPORATION: 4/4/11 PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec; 105.4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad 11-O683 4/8/11 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Please provide a statement on the Title Sheet of the plans to show compliance with the current Codes. The following are the correct current Codes: a) The 2010 edition of the California Building Code (CBC) adopts the 2009 International Building Code (IBC) and the 2010 California Amendments. b) The 2010 edition of the California Electrical Code (CEC) adopts the 2005 National Electrical Code (NEC) and the 2008 California Amendments. c) The 2010 edition of the California Mechanical Code (CMC) adopts the 2006 Uniform Mechanical Code (UMC) and the 2009 California Amendments. d) The 2010 edition of the California Plumbing Code (CPC) adopts the 2006 Uniform Plumbing Code (UPC) and the 2009 California Amendments. e) The 2010 edition of the California Fire Code (CFC) adopts the 2009 Uniform Fire Code (UFC) and the 2007 California Amendments. f) The 2008 edition of the California Energy Efficiency Standards. 2. Provide evidence of Health Department approval (for restaurants), where regulated by the local Health Department. 3. Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the 885# and 1200# rooftop air handler units. Include all calculations and finding on the plans. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. 4. Please review the requirements, revise the plans appropriately and imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment #80-6 to the plans. City of Carlsbad 11-0683 4/8/11 5. Provide complete kitchen hood plans, details, and calculations to show compliance with UMC, Chapters, Part II • Show the required replacement air for each kitchen hood to replenish the air exhausted. Include an air balance schedule. The exhaust and make-up air systems shall be connected by an electrical interlocking switch. UMC 511.3 6. Please note in the general wiring notes on the plans "AC Cable is not allowed in A, B, E, H, F, M, S and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits". 7. Show that the water closet is located in a space, per Section 1115B.3.2.3, which provides: a) A minimum front clearance of: b) A clear space in front of the water closet measuring 60" wide by 48" in front not obstructed by the urinal. Section 1115B.4.1.2. CLEAR FIOOR SPACE HATCH ED PORTION I ^MANEUVERING SMC6 MANEUVERING SPACE " 8. Show that accessible lavatories comply with the following, per Sections 1115B.4.3: a) When lavatories are adjacent to a side wall or partition, there shall be a minimum of 18" to the center line of the fixture to the wall. 9. Show that grab bars comply with the following, per Section 1115B.8: a) They shall be securely attached 33" above the floor, and parallel. NOTE: Where a tank-type toilet is used which obstructs placement of the rear grab bar at 33", the rear grab bar only may be installed as high as 36". 10. Per Section 1115B.8, show on the plans <40" height for: a) The operable parts of at least one: i) Paper towel dispenser, ii) Sanitary napkin dispenser. City of Carlsbad 11-0683 4/8/11 iii) Waste paper disposal. iv) Other similar dispensing and/or disposal fixtures, v) The bottom edge of mirrors To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City rof Carlsbad 11-0683 4/8/11 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 11-0683 PREPARED BY: Doug Moody DATE: 4/8/11 BUILDING ADDRESS: 2641 Gateway Rd Suite 102 BUILDING OCCUPANCY: A2 TYPE OF CONSTRUCTION: VB BUILDING | AREA PORTION (Sq. Ft.) Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code 1861 cb Valuation Multiplier 46.56 By Ordinance Reg. Mod. VALUE ($) 86,648 86,648 Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: I I Repetitive FeeRepeats Complete Review D Other t—1 Hourly EsGil Fee Structural Only Hr. @* $586.78 $381.41 $328.60 Comments: Sheet 1 of 1 macvalue.doc + PLANNING/ENGINEERING APPROVALS PERMIT NUMBER Aft 1 (DATE ADDRESS RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR (<$17,000.00) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER DATE ENGIN DATE Q:\FDEng\Oevelopment Servic8s\Correspondence\OntiverosVfcir planchec*ing\BUILDING PLANCHECK CKLIST FORM - PLANNING ENGINERING APPROVALS.docx o l T (_1(j I/) * * * D_ D_ Q_n n n PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB11-0683 Address 2641 Gateway Rd Planner Chris Sexton Phone (760) 602-4624 APN: 213-191-25 Type of Project & Use:Net Project Density:DU/AC Zoning: P-C General Plan: RH/L/CF Facilities Management Zone: \T_ CFD (in/out) #_Date of participation: Remaining net dev acres:. Circle One (For non-residential development: Type of land used created by this permit: Legend: Kl Item Complet Environmental Review Required: DATE OF COMPLETION: m Incomplete - Needs your action YES D NOD TYPE Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES D NO D TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES Q NO n CA Coastal Commission Authority? YES D NO D If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Habitat Management Plan Data Entry Completed? YES D NO D If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) Inclusionary Housing Fee required: YES D NO Q (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES D NO D (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens; Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) H:\ADMIN\TempIate\Building Plancheck Review Checklist.doc Rev 4/08 Site Plan: Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. DD D IEI D D Policy 44 - Neighborhood Architectural Design Guidelines 1. Applicability: YES D NO D 2. Project complies: YES D NCQ Zoning: 1. Setbacks: Front: Interior Side: Street Side: Rear: Top of slope: Required Required. Required Required Required 2. Accessory structure setbacks: Front: Interior Side: Street Side: Rear: Structure separation: Shown Shown Shown Shown Shown Required Required Required Required Required Shown Shown Shown Shown Shown 3. Lot Coverage:Required Shown D 4. Height:Required Shown Spaces Required Shown5. Parking: (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments 1) Please show how new roof mounted equipment will be screened. See attached handout. 2) Please take off the sign information on sheet A200. OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER^^nDATEg- H~ 1 1 H V/q C U3 / toe H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev 4/08 Carlsbad Fire Department r Plan Review Requirements Category: TI, COMM Date of Report: 05-20-2011 Reviewed by: Name: Address: RAY GABLE 158 WEST MAIN ST LENA IL 61048 Permit #: CB110683 Job Name: ELEVATION BURGER: 1861 SF VANI Job Address: 2641 GATEWAY RD CBAD St: 102 vwwvvvwv ua&a^e1&^ xptf^tf lyj^yl'ifVMy^fyy ^ifl'i^fi^ytiFKntfifip^B! vvv^x/vvvvvvvv'vvvvx/x/x/vxfvvvvx/vx/vx/x/vvv vvv Conditions: Cond: CON0004627 [MET] ** CITY OF CARLSBAD FIRE DEPARTMENT - APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 05/20/2011 By: GR Action: AP Cond: CON0004629 [MET] Article 1 of the California Fire Code for permits required for this business. Assembly Occupancy permit required. Contact this office for further details at 760-602-4665. Entry: 05/20/2011 By: GR Action: AP Cond: CON0004628 [MET] Any room having an occupant load of 50 or more, where fixed seats are not installed, shall have the capacity of the room posted in a conspicuous place. Entry: 05/20/2011 By: GR Action: AP CONDITIONAL RECOMMENDATION FOR APPROVAL T -T^,r ^.^agel of 3BLlXr. DEP1 Curr CONDITIONS FOR APPROVAL Make The Following Revisions to the following sheets Over The Counter: G100 Revise VN to VB (See 2010 CBC Table 601) A120 Add note to Interior Finish Plan Notes; All finish materials shall be in accordance with CBC Chapter 8. Daryl K. James & Associates, Inc. Plan Checker: J. Charles Weber Date: May 8, 2011 JURISDICTION: Carlsbad Fire Department APPLICANT: Ray Gable 158 West Main St., Lena, IL 61048 815-369-9155 x 108 raygable@lingledesign.com PROJECT NAME: Elevation Burger CB 110683 PROJECT ADDRESS: 2641 Gateway Rd Suite 102, Carlsbad, CA PROJECT DESCRIPTION: Tenant build out of existing 1862 square foot shell for A-2 restaurant This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. • CORRECTIONS OR MODIFICATIONS TO THE PLANS MUST BE CLOUDED AND PROVIDED WITH NUMBERED DELTAS AND REVISION DATES. | = Correction(s) made for Recommendation for Approval criteria | = Correction required before meets Recommendation for Approval Criteria PLEASE SEND OR DELIVER REVISED PLANS DIRECTLY TO and DIRECT ANY QUESTIONS REGARDING THIS REVIEW TO: J. Charles Weber 9146 Bubbling Wells Rd. Lakeside, CA 92040 (619) 933-3767 embersnoop@cox.net Page 2 of 3 ;' t DEFERRED SUBMITTALS (ADVISORY STATEMENTS TO BE DENOTED ON ALL PLANS - TITLE PAGEFS1): i Automatic Fire Sprinkler Systems: A separate plan review, inspection and permit issued by the City of Carlsbad is required. Installation of, and modifications to, the automatic fire sprinkler system shall in accordance with NFPA 13 and Chapter 9 of the California Fire Code. i Fire Alarm Systems: Fire Alarm System plans, modifications, installation to be in compliance with Chapter 9 of the California Fire Code and NFPA 72 National Fire Alarm Code (as adopted and amended by State of California). i Commercial Kitchen Hood Fire Protection System A separate plan review, inspection and permit issued by the City of Carlsbad is required for commercial kitchen cooking systems requiring fire protection.. Commercial Kitchen Hood Fire Protection System plans, modifications and installation to be in compliance with Chapter 9 of the California Fire Code. Wet chemical extinguishing systems shall be in compliance with UL 300 standards. CORRECTION(S): i 1. Page G002 Division 1- General Conditions, "G" Layout of Work Item 9 - "Contractor shall install portable fire extinguishers (Type 2A-10 BC) per IFC section 906." Change IFC to CFC | 2. Page G-100 "Building Information" - Place Deferred Submittal Statements in this section for reference i 3. Page G-100 "Building Information" - The California Fire Code is not referenced as applicable to the project. Insert reference to California Fire Code in the Code Table under Building Information i 4. Page G-100 "Building Information" - All referenced Codes in the Code Table are listed as the 2007 editions. Change applicable Codes to the 2010 Edition The corrected plans state that the "2010 California Fire Code adopts the 09 UFC and 07 California Amendments." Please correct this to - "2010 California Fire Code adopts the 2009 IFC with 2010 California Amendments." | 5. Page G-100 "Building Information" - For clarification purposes, does the applicant/owner have specific control over the patio dining area south of the Tenant Build Out space and separated by an intervening occupancy? The Occupant Load for the Tenant Build Out premises defines a maximum load of sixty-two 62 people for interior space. However, the Table and Seating Schedule adds another fifty-two (52) occupants for exterior/patio seating. No definitive plans are provided to evaluate the exiting and occupant load calculations for the patio dining area. Please clarify whether the applicant has exclusive or shared control over the patio dining area. Provide To- Scale plan for egress and occupant load plan review and evaluation if exclusive control over the patio dining area rests with Elevation Hamburger. Page 3 of 3 | 6. Page Q-110- Fire Extinguisher Detail Note 1 - "Fire Extinguisher must have a minimum of "2A-10BC" Rating and Class K shall be within 30'0" travel distance of all cooking surfaces per NFPA 10, Sec. 5.7 2002 Edition - delete reference to 2A-10BC extinguisher for this note; Class K extinguisher shall be within 30' travel distance of all cooking surfaces per CFC 906.1 Note 4- "Install new fire extinguisher (OFCI) (minimum Type 2A-10BC). Wall mount extinguisher -T.O. 60" AFF MAX, B.O. min 4" AFF - protrusion into path of circulation 4" max." The plans denote a 2A-10BC, designated as Code "5", immediately adjacent to and serving the kitchen area. Kitchen areas are considered Extra Hazard Spaces per NFPA 10 and the California Fire Code, requiring a minimum 4-A 40BC extinguisher within thirty (30) feet. California Fire Code section 906.9 requirements for height of installation: a. Extinguishers weighing less than 40 pounds - top of extinguisher no more than five (5) feet above the floor. b. Extinguishers weighing more than 40 pounds - top of extinguisher no more than 3.5 feet above ground. c. Minimum clearance between floor and bottom of extinguisher - four (4) inches I Change fire extinguisher coded "5" and rated as 2A-10BC to "4A-40BC" rating. i Per Note 2 - it is recommended that the applicant consult with the Carlsbad Fire Prevention Division concerning the total quantity of extinguishers needed for the premises and hazards presented. The 4A-40BC extinguisher designated for mounting in the kitchen area meets the minimum code requirement for extinguisher placement and travel distances in the facility; however, the CFD may require an additional extinguisher with a 2A-10BC rating for the Light and Ordinary Hazards presented by the dining and serving areas of the facility. § 7. Page M-4 "Hood Drawings" - Add Deferred Submittal Advisory Statement to this page - 'A separate plan review, inspection and permit issued by the City of Carlsbad is required for commercial kitchen cooking systems requiring fire protection.. Commercial Kitchen Hood Fire Protection System plans, modifications and installation to be in compliance with Chapter 9 of the California Fire Code. Wet chemical extinguishing systems shall be in compliance with UL 300 standards." E^GSSI Structural Engineers Calculations for Elevation Burger Mechanical Upgrades Carlsbad, CA LingleDesignGroup 158 West Main Street Lena, H 61042 April 2011 PROiECT Structural Engineers 0,ENGR. 'Pj SHEET_ OSS1 NO. DATE 1' t'4"') £ ft s* Hvt, 0 F ' .-*™-* I (-1 - -^) •s •?*{ f$f "' t f ) -f w $%\ ^ t H y J\ Standard Stracttms Inc. P.O. Box K Santa Rosa, Ca. 95402 (877)980-7732 Fax:{?07)838-«37? www.ssispec.com COMPANY July t6,2007 14:38 PROJECT Bressi Ranch Retail Carlsbad Design Check Calculation Sheet SSI Sizer 2.01 LOADS (Ite,psf,orptt) : Name Dead Live LoadS Type bead Non-SnowDeed Distribution Full Area Full area Point Magnitude Start End 15.00 (24.0)* 20 .£0 C24.0)*/foo^ Location [ft] Start End 6. 00 Units psf psf Ibs ""Tributary Width (ia} V^t^-""" MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in): Bead Live Total Bearing: Capacity Req'd lisa.Stiffener 761 530 1351 2000 1-3/4 No 524 590 1114 2000 1-3/4 NO 18" SSI 32M Spaced at 24" o.c.; Flange specific gravity = 0.50 SECTION VS. DESIGN CODE using NDS 2001: (Ibs, Ibs-ft, or in) Criterion Shear Bending (+) Dead Defl'n Live Def 1 ' n Total Defl'n analysis Value V » 1351 M «• 8862 0.67 = L/525 0.63 = L/558 1.31 - L/270 Design Value Vr = 3050 Mr = 11876 0,98 - L/360 1,47 = L/240 Analysis /Design (%) V/Vjr = 44.30 M/Mr = 74,62 64.49 88.68 ADDITIONAL DATA: fftCTORS: F CD CM Ct EV1 n/a 1.25 1.00 1.00 Pb'+ n/a 1.25 1,00 1.00 B* n/a 1.00 1.00 CL CF Cfn Cr 1.000 1.000 1.00 1.07 Cfrt 1.00 1.001.00 Ci 1.00 1.001.00 Cn LC# 1.00 2 2 Shear : LC #2 = D+C, V = 1351 Ibs Bending(*); tc #2 = D+C, M « 8862 Ibs-ft Deflection: LC 12 = D-t-C EI= 1152e06 Ib-in2 C= 9.84eQ6 in-lb/±n Total. Def lection = 1.00(Dead Load Deflection.) 4 Live Load Deflection. (D-dead L=live S=snow w=wind i=lapact c=constraction CLd=concentrated) (All LC's are listed in the analysis output) Load coatoinations: SSCE 7-02 DESIGN NOTES; 1. Please verify that the deflection limits are appropriate for your application. 2. This analysis is for Standard Structures Inc (SSI) Joist products furnished by SSI only. Product substitutions wifl void this analysis. 3. This analysis assumes that the top chord of ihe designed product is braced over the ftifl length. 4. Moment has been increased for repetitive member usage. 5. Additional bracing may be required at cantilevers, at unsupported edge and should be reviewed for upiift loading. 6. The product listed above must be supported on a member with adequate tearing and nailing. 7. The specific protfuet application toads, spans, and spactegs have been prowled by ettere and have net been reviewed by Standard Structures, Inc. for accuracy. IIS sores vs'cws^Y) NOIiVA31i If ill m III 11i IIflii Illl! WEIGHTS & DIMENSIONS (cont.) I. DIMENSIONS ARE [H INCHES, DIMENSIONSIN ( ) ARE IN MILLIMETERS. CENTER OF GRAVITY DIRECTION OF AI8 FLO* TOP LEFT HPCURB «6T» s — coNrcoi eoiA[([SS PANEL WIIOMl— 'fJCIORtminuet „.„.,.tiscowcci f~ "*mu ; IHKXW BLOMR KCCS5 /-MII8LE ' ca 00 T T i i : • no FRONT £ STD.-CONKN5ATEtSMN R10HT t iETBRK JL BiRMEiiicAl« ^ BEUEF FIW rtLTEi UCCSS P«NEl(TWH-lESSl inw» ecu4CCCSS PAN! I [OTOENSERcon BACK Vertical Connections / Economizer *- 6-i/aI1HI Horizontal Connections / Economizer A 8 C D E C CODKCIIOK SUES 1 3/8- (351 0)» FIELD POKER SUPRt HDIE ? 1/2" [Ml VIA POIER SUPPLY KNOCKOUT t 3/4- ($1) 01* GUM ACCESS PLUG 1/6- {HI CIA FIELD CONTROL HIRING ROLE 3/r-H HPT CONDENSATC DRAIN t • lill OIA POWER SUPPLY IMOCH-WT imu-THt-ensE cmmTHESE HDLCS KWIED rm IUEtttimiMtum V X 1 iMumCOMMIT SUE 1«" 1H" 1 1/4" ItK) V(REUSE uc. IW KI«B REO'D HOLESIZES IHAI.I Iff 11! !>My itt.il \ Uf IK.il rO» ••TMU-1HE-BUCW fACTOBT OPTIOK.riTHNCS FOR Oltt 1 1 1 ME PtOVICCD Fig. 5 - Dimensions 50TCQ 08-09 UNIT StTCOWS 5STCOMS J tt 3/811 253) IS 3/BM2S31 K 31 1/4[9JE] 31 1/4 [SJtl H 23 T/81(091 23 1/811051 C08B77 22 WEIGHTS & DIMENSIONS (cont.) UNIT 50TCQD08 50TCOD09 STD. UNIT WEIGHT IBS. 885 910 KG. 401 413 CORNER WEIGHT (A) IBS. 187 ZOO KG. 85 91 CORNER WEIGHT (8) IBS. 158 166 KG. 72 75 CORNER WEIGHT (C! LBS. 247 247 KG. 112 11? CORNER WEIGHT (0) LBS. 293 297 KG. 133 135 C.G. X 39 15/H [1014] 39 5/8 [1006) r 35 1/4 t895) 34 1/2 (8761 Z 23 1/2 1597] 23 1/2 [5971 CORNER A CD CORNER D C08678 Fig. 6 - Dimensions 50TCQ 08-09 Fig. 7 - Service Clearance LOG A B C D DIMENSION 48- in. (1219mm) 18- In. (457mm) 18-in, (457mm) 12-in. (305mm) 42-rn. (1067mm) 36-in. (914mm) Special 36-in. (914mm) 18-in. (457 mm) 42- in. (1067mm) 36-in. (914mm) CONDITION Unit disconnect is mounted on panel No disconnect, convenience outlet option Recommended service clearance Minimum clearance Surface behind servicer is grounded (e.g., metal, masonry wall) Surface behind servicer is electrically non-conductive (e.g., wood, fiberglass) Check for sources of flue products within 10-ft of unit fresh air intake hood Side condensate drain is used Minimum clearance Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) Surface behind servicer is electrically non-conductive (e.g., wood, fiberglass) 23 WEIGHTS & DIMENSIONS (cont.)b ROOFCURB ACCESSORY CRRFCURB003A01 CRRFCURB004A01 A 1'-2" [3561 2'-0" [610] UNIT SIZE 50TCQD08, 09 NOTES; 1. ROOFCURB ACCESSORY IS SHIPPED DISASSEMBLED. 2. INSULATED PANELSj 1" THK. POLYURETHANE FOAM, 1-3/4 * DENSITY. 3. DIMENSIONS IN t 3 ARE IN MILLIMETERS. 4. ROOFCURB: 18 SASE STEEL ON 1<T CURB, AND IB BASE STEEL ON 24* CURB.5. ATTACH DUCTWORK TO CURB. (FLANSE5 OF DUCT REST ON CURB) 6. SERVICE CLEARANCE A' ON EACH SIDE. 7. ^^ DIRECTION OF AIR FLOW. 8. CONNECTOR PACKAGES CRBTMPWR001A01 AND 2A01 ARE FOR THRU-THE-CURB TYPE CONNECTIONS. PACKAGES CRBTHPWR003A01 AND 4A01 ARE FOR THE THRU-THE-BOTTOM TYPE CONNECTIONS. CONNECTOR PKG. ACC. CRBTMPMR001A01 CRBTMPWR002A01 CRBTMPWRDQ3A01 CRBTMPHR004A01 B 2'-8 7/16' [827] C r-io IS/IB"ISB31 0 ALT DRAIN HOLE 1 3/4' [44. 53 POWER 3/4'M93NPT 1 1/4 [31.73 3/4"tl93NPT 1 1/4* [31. 7] CONTROL 1/2"[!2.?]NPT . ACCESSORY PWR 1/2'[12.7)NPT "ITS D'-3" 1 '-3 1/4"1387] 0"-0 7/16"mi(BOLT HEADS! O'-O 7/16"till-" 'i-X "\ CX r* *- v \ /-V*1--;'' 'f'\~~N '*•'-'--'' '"' ]tlf~ v' / / "i-'' i "B* 1 SUPPLY AIB OPENING 1 1fa) / /RETURN AIROPENING "C" . r-B )5/16" .1 Li '-2 7/8'(765) 1 r~ (37B) O'^j-J L /'"t .--. 3'-;11 D'-O ?tilI80LT \ S/B"006] /16" EADS) O'-O 7/16" KI13 (SUPPLIED «TH CUBB) DUCT (FIELD SUPPLIED) — TYPICAL (4) SIDES COUNTER FLASHING (FIELD SUPPLIED) -IOOFIM! FELT(FIELD SUPPLIED) CAMT STRIP (FIELD SUPPLIED)IFING MATERIAL (FIELD SUPPLIED) SECTION 'C-C' SCALE 111 [BOLT HEADS) MICROHETL "HICfi«.OK" FASTENING OiVICE IS ACCEPTABLE ALTEfiNATE CONSTRUCTION. Fig. 8 - Curb Dimensions SOTCQ 08-09 24 SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HW BP DATE / / Business Name Elevation Burqer Project Address 2641 Gateway Rd, Ste 102 Mailing Address 158 W. Main St Project Contact Ray Gable Business Contact Ron Weinberq CityCarlsbad City Lena State CA State IL Telephone # ( 619} 519-0510 Zip Code 92008 Zip Code 61048 APN# 213-191-25-00 Plan File# Telephone # (815 ) 369-9155 x!08 The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT- HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Facility's Square Footage (including proposed project): 1861 Occupancy Rating: A2 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 14. OtherHealthHazards 3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials <T5. NoneofThesS> 4. Flammable Solids 8. Unstable Reactives 12. Radioactives PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Ave., Suite 110, San Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED. Project Completion Date: _?_6_/_3_0/_ 11_ Expected Date of Occupancy: 07 / Ol/ 11 YES D CalARP Exempt Date Initials D CalARP Required Date Initials D CalARP Complete Date Initials NO (for new construction or remodeling projects) 1. D S Is your business listed on the reverse side of this form? (check all that apply). 2. D IS! Will your business dispose of Hazardous Substances or Medical Waste in any amount? 3. D S Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, 200 cubic feet, or carcinogens/reproductive toxins in any quantity? 4. D E Will your business use an existing or install an underground storage tank? 5. D [El Will your business store or handle Regulated Substances (CalARP)? 6. D |&] Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? 7. D El Will your business store petroleum in tanks or containers at your facility with a total storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition permit. Note: if the answer to questions 4 or 5 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation, except demolition or renovation of residential structures of four units or less. Contact the APCD for more information. YES NO 1 • CD S Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at httD://www.sdaDcd.oro/info/facts/Dermits.pdf. and the list of typical equipment requiring an APCD permit on the reverse side of this from. Contact APCD if you have any questions). 2. D D (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? (Search the California School Directory at http://www.cde.ca.aov/re/sd/ for public and private schools or contact the appropriate school district). IE! Has a survey been performed to determine the presence of Asbestos Containing Materials? IJ3 Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos? El Will there be demolition involving the removal of a load supporting structural member? 3. 4. 5. D D D Briefly describe business activities: Preperat ion of food for customer consumption. Briefly describe proposed project: Tenant build Out of an existing space to a restaurant. I declare under penalty of perjury that to the best of my knowledge and belief the responses made herein are true and correct. Ray Gable " " Name of Owner or Authorized Agent Signature of Owner or Authorized Agent 03/ 24 / 11 Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:. BY: FOR OFFICIAL USE ONLY: DATE: EXEMPT OR NO FURTHER INFORMATION REQUIRED COUNTY-HMD*APCD RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY COUNTY-HMD APCD RELEASED FOR OCCUPANCY COUNTY-HMD APCD A stamp in this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. HM-9171 (02/11) County of San Diego-DEH-Hazardous Materials Division COUNTY OF SAN DIEGO _kl DEPARTMENT OF • ENVIRONMENTAL HEALTH PLAN REVIEW I HEREBY CERTIFY THAT THE5 SUPERVISION AND TO THE 61 WTTH ALL APPLICABLE-LAWS, i REGISTRATION NO.: DATE: MAY 0 2 201 N.T.S. ARCHITECTS DESIGN WITHOUT i SINCE DIRECT CONSTRUCTION i OF THE ARCHITECT'S BASIC 5EF DESIGN GROUP AVAILS ITSELF' FAX, AND EMAIL) IN ORDER TO, ALTHOUGH MANY ISSUES CAN PARTICIPATION IS ADVISABLE. I DISCRETION OF THE CONTRAC RESPONSIBILITY FOR INTERPRE ARCHITECT IS DENIED THE OPP RESOLUTION OF ISSUES OR PF CONNECTED THERETO. LINGLE FROM MODIFICATIONS OR CH, CONDITIONS OR CIRCUM5TAN THE RELATIONSHIP BETWEEN \ SINKS AS SHOWN ON THE PLl CONTRACTOR MUST COMPLf PLACEMENT. S NOTED DED ACOUS TILE;ORE JLE N HNS ICATION t I SINK ESS STEEL ARD \Gt STRUCTURAL ETRICAL l IF BEAM TEL. T*G THK. T.O.C. T.O.P. T.O.S. T.O.W. TYP. UBC U.N.O. V.B, VERT. V.C.T. V.T.R. W. W/ W.C. WD TELEPHONE TONGUE AND GROOVE THICKNESS TOP OF CURB TOP OF PARAPET TOP OF SHEATHING TOP OF WALL TYPICAL UNIFORM BUILDING CODE UNLESS OTHERWISE NOTED VINYL BASE VERTICAL VINYL COMPOSITION TILE VENT THROUGH ROOF WEST WITH WATER CLOSET WOOD W.H. WATER HEATER W/0 WITHOUT W.R. WATER RESISTANT COUNTY OF SAN DIEGO DEPARTMENT OF / ENVIRONMENTAL HEALTH / PLAN CHECK NOTICE" CALL 858-505-6660 TO SCHEDULE PRELIMINARY, MID AND FINAL INSPECTION IF THERE IS NO CONSTRUCTION BEGUN AFTER ONE (1 FROM THE DATE THE PLANS WERE APPROVED, THEN 1 APPROVED PLANS WILL BE VOIDED AND NEW PLANS W BE RESUBMITTED FOR APPROVAL. \ \ YEAR HE UST yi^-- DETAIL f S#^\ ^ #u j ^r^- SHEET! EXTERIOR ELEVATION ^^-5UB-C \J^L' ^(T ^^X^CMFpl 1 # INTERIOR ELEVATIol, f 3M Fire Protection Products ML 07/27/11 Rob Petroni 3M FPP Manufacturers Agent Southern California Project: Elevation Burger, Carlsbad CA Contractor: Shrader & Martinez Fire Stopping Category: Discussion / Grease Duct Topic: Requesting letter stating that banding securely fastened with sheet metal screws in lieu of using the crimping method is acceptable for duct wrap applied around a grease duct. Requesting to use 1/2 in. to max 1-1/2 in. banding. Discussion: This letter shall address if it is acceptable to use sheet metal screws in lieu of crimping methods when applying banding to secure duct wrap to a grease duct application. 1. 2. The inclusion of using sheet metal screws in lieu of crimping the banding is not expected to adversely affect the performance of the system in a fire scenario, provided all other system parameters are met and that the sheet metal screws are made of similar material as the banding and are not positioned so that they penetrate into the duct wrap material. The inclusion of minimum 1/2 in. to max 1-1/2 in. banding is not expected to adversely affect the performance of the system in a fire scenario, provided all other system parameters are met and the banding meets the requirements as listed in the Fire Barrier Duct Wrap 615+ Data and Installation Guide. On: Fjre Bjlfrier Duct Wrap 615+ Product Data Sheet and Installation Guide ter Prepared By: neis Technical Servi' X ntattve Reviewed By: 540957 Rev. 1 AEK 7-28-11: Added % in, stainless steel banding Rev. 3 AEK 7-28-11: Clarification on sheet metal screws cc: Ernie Stumpf 3M Building and Commercial Services Division 3M Center, Building 223-2N-20 St. Paul, MN 55144-1000 Page 1 of 1 n 5 Q AY RD8*svU T- 5 -«?S raceo: §OD LU O w aJ|s^<O QJ> City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 07-07-2011 Plan Check Revision Permit No:PCR11085 Building Inspection Request Line (760) 602-2725 Job Address: 2641 GATEWAY RD CBAD St: 102 Permit Type: PCR Status: ISSUED Parcel No: 2131912500 Lot#: 0 Applied: 06/21/2011 Valuation: $0.00 Construction Type: NEW Entered By: JMA Reference*: CB110683 Plan Approved: 07/07/2011 PC#: Issued: 07/07/2011 Project Title: ELEVATION BURGER: RELOCATE Inspect Area: GREASE INTERCEPTOR//CORRECTION IN ELECTRICAL PANEL Applicant: Owner: GARY STEBBINGS LNR CPI BRESSI RETAIL L L C 160 DRY CREEK RD C/O LNR PROPERTY CORP SEDONA 4350 VON KARMAN AVE #200 AZ 86336 NEWPORT BEACH CA 92660 928-301-8838 Plan Check Revision Fee $107.50 Fire Expedited Plan Review $0.00 Additional Fees $0.00 Total Fees: $107.50 Total Payments To Date: $107.50 Balance Due: $0.00 FINAL APPROVAL Inspector: Date: Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66Q20(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. CITY OF CARLSBAD PLAN CHECK REVISION APPLICATION B-15 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov lOfTPlan Check Revision No. Project Address 2-pil Contact fery SrggA/Jti ph <?^ 3a/-gS3$> Fax Contact AddnL IbO tti-V C&€&t. Original Plan Check NoA ILL Sfe l6Z- _ Date V Q &?Q 3 Email General Scope of Work Original plans prepared by an architect or engineer, revisions musTb'e signed' & stamped by that person. 1 Elements revised: [] Soils n Energy QPlansCalculations Describe revisions in detail //t^Qfe. /^/ List page(s) where each revision is shown List revised sheets that replace existing sheets /t, 5 Does this revision, in any way, alter the exterior of the project? |3 Yes O Does this revision add ANY new floor area(s)? CU Yes |x[| No 7 Does this revision affect any fire related issues? Q Yes 0 No 8 Is this a complete set? D Yes 0 No fi^u-Y Ttf*. No 1635 Faraday Ave d, CA 92008 Phone: 760-602-2717/2718/2719 www.carlsbadca.gov Fax: 760-602-8558 EsGil Corporation In (Partners Kip with government for (Building Safety DATE: 6/29/11 a APPLICANT 8t JURIS. JURISDICTION: City of Carlsbad a PLAN REVIEWER Q FILE PLAN CHECK NO.: 11-0683 PCR11-085 SET: I PROJECT ADDRESS: 2641 Gateway Rd Suite 102 PROJECT NAME: Elevation Burger - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. /\j The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: XI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person REMARKS: Applicant to add notes in red on sheet P1 and P2 to City sets. By: Doug Moody Enclosures: EsGil Corporationn GA n EJ n PC 6/23/11 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576 EsGil Corporation In Partnership with government for (Building Safety DATE: 7/7/11 JURISDICTION: City of Carlsbad aiPtTtfTREVIEWER a FILE PLAN CHECK NO.: 11-0683 PCR11-089 SET: I PROJECT ADDRESS: 2641 Gateway Rd Suite 102 PROJECT NAME: Elevation Burger - Revision to Reflective Ceiling [XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: IXI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person REMARKS: By: Doug Moody Enclosures: EsGil Corporation D GA D EJ D PC 6/30/11 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 City of Carlsbad 11-0683 PCR11-089 7/7/11 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE PLAN CHECK NO.: 11-0683 PCR11-JURISDICTION: City of Carlsbad 089 PREPARED BY: Doug Moody DATE: 7/7/11 BUILDING ADDRESS: 2641 Gateway Rd Suite 102 BUILDING OCCUPANCY: A2 TYPE OF CONSTRUCTION: VB BUILDING PORTION Revision Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) cb Valuation Multiplier By Ordinance Reg. Mod. VALUE ($) Plan Check Fee by Ordinance Type of Review: I I Repetitive Fee^n Repeats D Complete Review $107.50 Q Other r- 1 Hourly EsGil Fee 1 $86.00 Structural Only Hr. @ $86.00 Based on hourly rate Comments: Sheet 1 of 1 macvalue.doc + BUILDING PLANCHECK - Development Service^ CITY OF CHECKM^T Land Development Engineering r*ADI CD API ^-Tr 1635 Faraday Avenue V-AKL5DAU E-36 760-602-2750 www.carlsbadca.gov ENGINEERING Plan Check for PCR11-^(CB11-683) Review# 1 Date: June 28, 2011 Project Address: 2641 Road APN; 213-191-25-00 Project Description: Changes in plumbing - relocate grease line/interceptor Valuation: na outside ENGINEERING contact: Linda CMiveros Email: Iinda.ontiveros@carlsbadca.gov Phone: 760-602-2773 Fax: 760-602-1052 Any outstanding issues will be marked with [XI. Please make the necessary corrections to the plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specification to the Building division for resubmittal to the Engineering Division. Items that conform to permit requirements are marked with [~7~ M&ad ATTACHMENTS: r TWrJ Engineerin9 Application f"~) Right-of-Way Application/Info. Sheet i / j Storm Water Form ! j Reference Documents OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT Notification of Engineering APPROVAL has been sent to j via on REV 4/30/11 PCR11-85 (CB11-683)Review # 1 1. SITE PLAN Provide a fully dimensioned site plan drawn to scale. Show: , £. North arrow ' / * Existing & proposed structures L / _ Existing street improvements _/_ Property lines (show all dimensions) I / Easements I Right-of-way width & adjacent streets / Driveway widths / J Existing or proposed sewer lateral , / Existing or proposed water service i Submit on signed approved plans: DWG No. Show on site plan: / Drainage patterns / Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. / )ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building". / i Existing & proposed slopes and topography Size, location, alignment of existing or proposed sewer and water service(s) that serves the project. Each unit requires a separate service; however, second dwelling units and apartment complexes are an exception. I j | U Sewer and water laterals should not be located within proposed driveways, per standards. Include on title sheet: [II] [j/j Site address [3/1 Assessor's parcel number [311] Legal description/lot number [Till For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. . Show all existing use of SF and new proposed use of SF. Example: Tenant improvement for 3500 SF of warehouse to 3500 SF of office. Lot/Map No.: Subdivision/Tract: Reference No(s): E-36 Page 2 of 6 REV 4/30/10 PCR11-85(CB11-683)Review # 1 2. DISCRETIONARY APPROVAL COMPLIANCE _/J Project does not comply with the following engineering conditions of approval for project no.: 3. DEDICATION REQUIREMENTS ~~~j Dedication for all street rights-of-way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 20.000.00 , pursuant to Carlsbad Municipal Code Section 18.40.030. For single family residence, easement dedication will be completed by the City of Carlsbad, cost $605.00. j/j Dedication required as follows: na 4. IMPROVEMENT REQUIREMENTS I All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $100.000.00, pursuant to Carlsbad Municipal Code Section 18.40.040. _/J Public improvements required as follows: na Construction of the public improvements must be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $ 441.00 so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the city prior to issuance of a building permit. Future public improvements required as follows: na E-36 Page 3 of 6 REV 6/30/10 PCR11-85 (CB11-683) Review # 1 5. GRADING PERMIT REQUIREMENTS The conditions that require a grading permit are found in Section 15.16 of the Municipal Code. r~~™1 [^[Inadequate information available on site plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial). This information must be included on the plans. If no grading is proposed write: "NO GRADING" | Grading Permit required. NOTE: The grading permit must be issued and rough grading approval obtained prior to issuance of a building permit. ~_^j Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) All required documentation must be provided to your Engineering Construction Inspector per the attached list. The inspector will then provide the engineering counter with a release for the building permit. /, i No grading permit required. • Minor Grading Permit required. See attached marked-up submittal checklist for project- specific requirements. 6. MISCELLANEOUS PERMITS ] RIGHT-OF-WAY PERMIT is required to do work in city right-of-way and/or private work adjacent to the public right-of-way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. | Right-of-way permit required for: E-36 Page 4 of 6 REV 6/30/10 PCR11-85 (CB11,683)Review # 1 COMPLETE FORMS E-29ANOB-24AND RETURN FOR ENGINEERING SIGN-OFF 7. STORM WATER Construction Compliance Projectjhreat Assessment Form complete. Project Threat Assessment Form incomplete. COMPLETE FORM E-34 FOR ENGINEERING SIGN OFF |/_] Requires Tier 1 Storm Water Pollution Prevention Plan. Please complete attached form and return (SW 11-268 ) Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2 SWPPP, payment of processing fee and review by city. Post-Development (SUSMP) Compliance rm Water Standards Questionnaire complete. ' Storm Water Standards Questionnaire incomplete. Please make the corrections, re-sign the questionnaire and resubmit with next submittal. j Project is subject to Standard Storm Water Requirements. See city Standard Urban Storm Water Management Plan (SUSMP) for reference. http://www.carlsbadca.qov/buslness/buildinq/Documents/EngStandsw-stds-vol4-ch2.pdf ] Project needs to incorporate low impact development strategies throughout in one or more of the following ways: Rainwater harvesting (rain barrels or cistern) Vegetated Roof Bio-retentions cell/rain garden Pervious pavement/pavers Flow-through planter/vegetated or rock drip line Vegetated swales or rock infiltration swales Downspouts disconnect and discharge over landscape [13 Other: E-36 Page 5 of 6 REV 4/30/10 PCR11-85 (CB11-683)Review # 1 9- WATER METER REVIEW . Domestic (potable) Use NA [Ill][IIIl Where a residential unit is required to have an automatic fire extinguishing system, the minimum meter size shall be a 1" meter. NOTE: the connection fee, SDCWA system capacity charge and the water treatment capacity charge will be based on the size of the meter necessary to meet the water use requirements. For residential units the minimum size meter shall be 5/8", except where the residential unit is larger than 3,500 square feet or on a lot larger than one quarter (1/4) acre where the meter size shall be %". 8. FEES SW11-268 [HI] [III] Required fees have been entered in building permit. Drainage fee applicable Added square feet Added square footage in last two years? [I] yes Permit No. Permit No. Project built after 1980 Impervious surface > 50% Impact unconstructed facility Fire sprinklers required Upgrade No fees required I yes ll]yes Dyes I13no no no no [I]no (is addition over 150' from center line) yes [I]no 10. Additional Comments E-36 Page 6 of 6 REV 4/30/10 PLANNING/ENGINEERING APPROVALS PERMIT NUMBER PCR 11-85 DATE 6/21/11 ADDRESS 2641 Gateway Rd #102 RESIDENTIAL ADDITION- MINOR (< 17,000.00) RETAINING WALL VILLAGE FAIRE OOL/SPA TENANT IMPROVEMENT COMPLETE OFFICE BUILDING SOLAR PANELS OTHER relocate grease interceptor/panel wiring PLANNER C/LAJJ4 J^A^y^ DATE Cy~5J ~l/ ENGINEER DATE H:\ADMIN\CODNTER/PLANNINC/ENGINEERING APPROVALS Carlsbad Fire Department Plan Review Requirements Category: PCR , Date of Report: 07-01-2011 GARY STEBBINGS Reviewed by: Name: Address: 160 DRY CREEK RD SEDONA AZ 86336 Permit #: PCR11089 Job Name: ELEVATION BURGER- REVISE Job Address: 2641 GATEWAY RD CBAD St: 102 INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot with the-arfljjifflhik i;nrl"irrm4H"Thii4rii'rln Pl-*-^ review carefully all comments ill n 1ml T\f uiiiiiMiwlTnill ITn in i ii"' j'lTlll iiiilnii , i||' ifi ilimi with changes "clouded", to this office for Conditions: Cond: CON0004740 [MET] THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Entry: 07/01/2011 By: cwong