Loading...
HomeMy WebLinkAbout2641 GATEWAY RD; 101; CB120517; Permit05-16-2012 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB120517 Building Inspection Request Line (760) 602-2725 Job Address: Permity Type: Parcel No: Valuation: Occupancy Group Project Title: 2641 GATEWAY RD CBADSt: 101 Tl Sub Type: COMM 2131912500 Lot#: 0 $73,840.00 Construction Type: 5B Reference # PICK UP STIX-1468 SF RETAIL TO RESTAURANT//INSTALL GREASE INTERCEPTOR Status: ISSUED Applied: 03/23/2012 Entered By: KG Plan Approved: 05/16/2012 Issued: 05/16/2012 Inspect Area Plan Check #: Applicant: CLINE DAN 18572 AVOLINDADR YORBA LINDA CA 92886 714-315-0099 Owner: REGENCY BRESSI LLC C/O CORNERSTONE REAL ESTATE ADVIS 100 WILSHIRE BLVD #700 SANTA MONICA CA 90401 Building Permit $568.22 Meter Size Add'l Building Permit Fee $0.00 Add'l Reel. Water Con. Fee $0.00 Plan Check $397.75 Meter Fee $0.00 Add'l Building Pennit Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $15.51 PFF (3105540) $1,343.89 Park Fee $0.00 PFF (4305540) $0.00 LFM Fee $0.00 License Tax (3104193) $0.00 Bridge Fee $0.00 License Tax (4304193) $0.00 BTD #2 Fee $0.00 Traffic Impact Fee (3105541) $0.00 BTD #3 Fee $0.00 Traffic Impact Fee (4305541) $0.00 Renewal Fee $0.00 PLUMBING TOTAL $128.00 Add'l Renewal Fee $0.00 ELECTRICAL TOTAL $40.00 Other Building Fee $0.00 MECHANICAL TOTAL $63.00 Pot. Water Con. Fee $0.00 Master Drainage Fee $0.00 Meter Size Sewer Fee $0.00 Add'l Pot. Water Con. Fee $0.00 Redev Parking Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 Green Bldg Stands (SB1473) Fee $1.00 HMP Fee ?? Fire Expedidted Plan Review $250.00 Green Bldg Standards Plan Chk ?? TOTAL PERMIT FEES $2,807.37 Total Fees: $2,807.37 Total Payments To Date: $2,807.37 Balance Due: $0.00 Inspector: FINAL Date: .APPROVAL ( Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" ol fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exactions." You have 90 days from the date this permit was Issued to protest inpisition of these fees/exactions. It you protest them, you must follow the protest procedures set forth in Govemment Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure lo timely follow that procedure will t)ar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or sen/Ice fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been oiven a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. 05-16-2012 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Storm Water Pollution Prevention Plan (SWPPP) Permit Permit No-.SW120096 Job Address: Permit Type: Parcel No: Reference #: CB#: Project Title: 2641 GATEWAY RD CBAD St: 101 SWPPP 2131912500 Lot#: CB120517 PICK UP STIX TI//GREASE INTERC Applicant: DAN CLINE 18572 AVOLINDADR YORBA LINDA 92886 714-315-0099 Status: ISSUED Applied: 03/23/2012 Entered By: Issued: Inspect Area: Tier: Priority: KG 05/16/2012 1 L Owner: REGENCY BRESSI LLC C/O CORNERSTONE REAL ESTATE ADVIS 100 WILSHIRE BLVD #700 SANTA MONICA CA 90401 Emergency Contact: SEAN PARDIS 714-465-6239 SWPPP Plan Check SWPPP Inspections Additional Fees $45.00 $55.00 $0.00 TOTAL PERMIT FEES $100.00 Total Fees: $100.00 Total Payments To Date: $100.00 BalanceDue: $0.00 FINALAPPROVAL DATE ^'^2 /2^ SIGNATURE CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717 / 2718 / 2719 Fax: 760-602-8558 wv^w.carisbadca.gov Plan Check fij3 iQA'^ll Est. Value Plan Ck. Deposit 7.7^ Date5-Z3^|2-SWPP JOB ADDRESS . T» / I PHASE # SUITE#/SPACE#/UNIT# 101 CT/PROJECT # # OF UNITS # BEDROOMS # BATHROOIi^S TENANT BUSINESS NAME CONSTR. TYPE occ. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) / A/Bw T.I. A<^rz /^lOk: (/fsr/x nersri^ ^H^T /Y^^r EXISTING USE GUSE / , PROPOSED USE IED USE / GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YES • # NO • AIR CONDITIONING YES • Noa FIRESPRINKLERS YES • NOD APPUCANT NAIVIE (Primary Contact) APPLICANT NAME (Secondary Contact) ADDRESS ADDRESS CITY STATE ZIP CITY STATE ZIP PHONE 7/V- 3^J^- CPQ^^ FAX PHONE FFAX EMAIL EMAIL PROPERTYOWNER NAME CONTRACTOR BUS. NAME ADDRESS ADDRESS 1/01 ^. CHAff^i^-J ^Id't' CITY STATE ZIP CITY STATE ZIP PHONE FAX PHONE FAX EMAIL EMAiL ARCH/DESIGNER NAME & ADDRESS STATE LIC.# ^ ^ _ _ CLASS :ITY BUS. LIC.# STATE LIC. # (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of tlie Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500}). Workers' Compensation Declaration: / hereby aflinn under penalty of perjury one of ttie followmg declarations: n I have and will maintain a certificate of consent to self-insure for worisers' compensation as provided by Section 3700 of the LaborCode, for the performance of the work for which this permit is issued. I have and will maintain worisers' compensation, as required by Soption 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance f^n "^10 h/f^V J^/^SC •f' Policy No. ^4/ ^ ^ C? / ^Expiration Date f 2. //7//2- This section need not be completed ifthe permit is for one hundred dollars ($100) or less. O Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In , addition to the cost of compensation, dvmages as provided for in Section 3706 of the Labor code, interest and attorney's fees. CONTRACTOR SIGNATURE '\ri/^ • AGENT DATE I hereby affimi that i am exempt from Contractor's License Law for the foiiowing reason: • I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are nol intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). n I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). • I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement • Yes • No 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): PROPERTY OWNER SIGNATURE •AGENT DATE THIS SECTION FOR NON •L 3 TIAt BUrtOING PERMITS ONLY Is the applicant or future building occupant required to submit a business plarijcutely hazardous materials registration form or risk management and prevention program under Seclions 25505,25533 or 25534 of the Presley-tanner Hazardous Substance Account Act? • Yes Bm Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air qualit^management district? • Yes (J-Mb Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? • Yes BiTo IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address B T I FlC, I certify that I have read ttte application and state Diatthe above information is conect and that the infbrrnation on the plans is accurate. I agree to comply with all Clly ordinances and State laws relating to building cons^ I hereby authorize representative of the City of Carisbad to enter upon the above mentioned property for inspeclion purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA pemiit is required for excavations over 5'0' deep and demolition or constmction of stmctures over 3 stories in height. EXPIFiATION: Every pennit issued by the Building Official under Ihe provisions of this Code shall expire by limitation and become null and void if the building or wori< authorized by such permit is not commenced within 180 days from the date of such pennit or if the building or work authprized by siiflh pemiit is suspended or abandoned at any time after Ihe worts is commenced for a period of 180 days (Section 106.4.4 Unifomi Building Code). veS*APPLICANT'S SIGNATURE / ^yT^T^/ f7 " DATE Inspection List Permit#: CB120517 Type: Tl COMM Date 08/22/2012 08/22/2012 08/22/2012 08/21/2012 08/21/2012 08/20/2012 08/17/2012 08/17/2012 08/15/2012 08/15/2012 08/15/2012 08/15/2012 08/09/2012 08/09/2012 07/26/2012 07/20/2012 07/19/2012 07/10/2012 06/26/2012 06/26/2012 Inspection Item 89 Final Combo Final Combo Final Combo Final Combo Final Combo Final Combo Final Combo Final Combo Rough/Ducts/Dampers Rough Combo Rough Combo Rough Combo Gas/Test/Repairs Gas/Test/Repairs Rough/Ducts/Dampers Interior Lath/Drywall Rough Combo Rough Combo Underground/Under Floor Rough/Topout Inspector PD PD PD PD PD PD PD PD PD PD PD Act AP Rl Rl PA Rl Rl Rl CA Rl AP Rl Rl Rl AP AP AP AP CO AP AP PICK UP STIX-1468 SF RETAIL TO RESTAURANT//INSTALL GREASE INTERC Comments NOD STE101 EARLY PM PLS NOD- FIRE AT 10 AM Wednesday, August 22, 2012 Page 1 of 1 CITYOF CARLSBAD Building Department INSPECTION RECORD INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE ON THE JOB CALL PRIOR TO MO P.M. FOR NEXT WORK DAY INSPECTION CB120517 2641 GATEWAY RD 101 PICK UP STIX-1468 SF RETAIL TO RESTAURANT//INSTALL GREASE INTERCEPTOR Tl COMM Lot#: CLINE DAN FOR BUILDING INSPECTION ^ALL: 760-602-2725 APPROVED TO COVER DATE: Type of Inspection Date Inspector Notes BUILDING FOUNDATION REINFORCED STEEL MASONRY • GROUT • WALL DRAINS TILT PANELS POUR STRIPS COLUMN FOOTINGS SUBFRAME • FLOOR • CEILING ROOF SHEATHING EXT. SHEAR PANELS FRAME INSULATION EXTERIOR LATH INTERIOR LATH & DRYWALL FINAL PLUMBING • SEWER AND BL/CO ^ • PL/CO UNDERGROUND J2^ASTE • WATER TOP OUT 0iVASTE • WATER TUB AND SHOWER PAN • GAS TEST • GAS PIPING • WATER HEATER • SOLAR WATER FINAL ELECTRICAL • ELECTRIC UNDERGROUND • UFER 1-i'r-IV ROUGH ELECTRIC WALLS ROUGH ELECTRIC CEILING h's • /t • ELECTRIC SERVICE • TEMPORARY • BONDING • POOL PHOTO VOLTAIC FINAL MECHANICAL UNDERGROUND DUCTS & PIPING • DUCT & PLEM. • REF. PIPING HEAT - AIR COND. SYSTEMS VENTILATING SYSTEMS FINAL CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE ITEMS ABOVE HAVE BEEN APPROVED FINAL Sign When Appropriate Building Dept. (Inspections) {760) 602-2725 / 1 Fire Department (760) 602-4660 Planning Department (760) 602-4602 ri Enqineerinq Dept. (Inspections) (760) 438-3891 Bui/ding Inspectors (7am-4pm) ^^60) 602-2700^ CMWD (760) 438-2722 Ext 7151 -\i 8/2009 1635 Faraday Ave. • Carlsbad, CA 92008 • 760-602-2700 • www.carlsbadca.gov SEE b,-"^K rOR SF EsGil Corporation In (Partnersfiip with government for (BuiCding Safety DATE: 4/27/12 • APPUCANT •(JURJ§) JURISDICTION: City of Carlsbad •PLANREVIEWER • FILE PLAN CHECK NO.: 12-0517 SET: III PROJECT ADDRESS: 2641 Gateway Rd Suite 101 PROJECT NAME: Pick up Stix - TI XI The plans transmitted herewith have been corrected where necessary and substantially connply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: IXI EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person ^ REMARKS: Applicant to slip sheet the plans at the City. By: Doug Moody Enclosures: EsGil Corporation • GA • EJ • PC 4/23/12 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In (Partnersliip with government for (BuiCding Safety DATE: 4/13/12 aj^PLlCANT 7^__^^7J, JURISDICTION: City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 12-0517 SET: II PROJECT ADDRESS: 2641 Gateway Rd Suite 101 PROJECT NAME: Pick up Stix - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. X The applicant's copy of the check list has been sent to: Dan Cline 18572 Avolinda Drive Suite 100, Yorba Linda, CA 92886 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Dan Cline Telephone #: 714-315-0099 Date contacted: M-17-1Z- (by:>>i.) Email: dan@danclineinc.com Fax #: 6 Mail Telephone ^ Fax In Person • REMARKS: By: Doug Moody Enclosures: EsGil Corporation • GA • EJ • PC 4/10/12 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 12-0517 4/13/12 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 2. Please revise the LTG forms to show the correct floor area of 1468 and not 1790. Correct all forms to show the correct allowable wattage and installed wattage. The allowable wattage is still incorrect based on the wrong floor area, please correct all LTG forms. 3. Please revise the MECH forms to show the correct floor area of 1468 and not 1890. Please provide a complete set ofthe revised MECH forms. 5. Please review the requirements, revise the plans appropriately and imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans. Please imprint the Building Department Roof Mounted Equipment Policies 80-6 and not the Planning Department roof screening requirements. 6. Show that dining facilities are accessible, per Section 1104B.5, as follows: a) Fixed seating, counters and/or tables shall comply with Section 1104B.5.4 as follows: i) Wheelchair access is required to all areas where each type of functional activity occurs. Please clarify the plans counter seating is shown along the north wall what height is this counter? If higher than 34" show a section 60" in length 28" to 34" in height. Please clarify the service counter the plans show a 42" wall at the transaction area and the Case detail show on A3 appears to show the counter 39 1/2" high? City of Carlsbad 12-0517 4/13/12 7. Show a level area, or landing, per Section 1133B.2.4.2: a) >60" in the direction of door swing. Show the required clear space at door 21 to the service area. 8. Show that the water closet is located in a space, per Section 1115B.3.2.3, which provides: a) A clear space in front of the water closet measuring 60" wide by 48" in front. Section 1115B.4.1.2. The restroom is too narrow to provide the required maneuvering space. See figure below 11B-1E California Building Code. CLEAR FiXXn SPACE ooonFennTTED TOSIMNGOVER )UTCHED PORTION Of MANEUVB;II«6 SPACE 'MWEWERIPK SPACE •• (a) CUEARANCES AT WATSt ClOSET To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes • No • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. Ifyou have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. EsGil Corporation In Partnership with government for (BuiCding Safety DATE: 4/2/12 • APPLICANT JURIS: JURISDICTION: City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECKNO.: 12-0517 SET I PROJECT ADDRESS: 2641 Gateway Rd Suite 101 PROJECT NAME: Pick up Stix - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ^ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. X The applicant's copy of the check list has been sent to: Dan Cline 18572 Avolinda Drive Suite 100, Yorba Linda, CA 92886 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. IX EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Dan Cline Telephone #: 714-315-0099 Date contacted: ^i^ht (by:KC) Email: dan(S)danclineinc.com Fax #: t Mail Telephone Fax In Person • REMARKS: By: Doug Moody Enclosures: EsGil Corporation • GA • EJ • PC 3/26/12 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 4/2/12 12-0517 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 12-0517 JURISDICTION: City ofCarlsbad OCCUPANCY: B USE: Restaurant TYPE OF CONSTRUCTION: VB ACTUAL AREA: 1468sf ALLOWABLE FLOOR AREA: STORIES: 1 HEIGHT: SPRINKLERS?: YES OCCUPANT LOAD: 48 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 3/23/12 DATE PLANS RECEIVED BY ESGIL CORPORATION: 3/26/12 DATE INITIAL PLAN REVIEW COMPLETED: 4/2/12 PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2009 International Building Code, the approval ofthe plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when vou submit the revised pians. City of Carlsbad 12-0517 4/2/12 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Provide evidence of Health Department approval (for restaurants), where regulated by the local Health Department. 2. Please revise the LTG forms to show the correct floor area of 1468 and not 1790. Correct all forms to show the correct allowable wattage and installed wattage. 3. Please revise the MECH forms to show the correct floor area of 1468 and not 1890. 4. Please revise the plans to show the restroom to be equipped with an environmental air exhaust fan sized to provide the minimum exhaust rate per Table 4-4 ofthe UMC. 5. Please review the requirements, revise the plans appropriately and imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans. 6. Show that dining facilities are accessible, per Section 1104B.5, as follows: a) Fixed seating, counters and/or tables shall comply with Section 1104B.5.4 as follows: i) Wheelchair access is required to all areas where each type of functional activity occurs. ii) Each dining, banquet and bar area shall have one wheelchair seating space for each 20 seats, with >1 space per functional area. b) Accessible seats are integrated with the general seating to allow a reasonable selection of seating area and to avoid having one area specifically highlighted. City of Carlsbad 12-0517 4/2/12 7. Show a level area, or landing, per Section 1133B.2.4.2: a) >60" in the direction of door swing. b) >48" in the direction opposite the door swing. 8. Show that the water closet is located in a space, per Section 1115B.3.2.3, which provides: a) A clear space in front of the water closet measuring 60" wide by 48" in front. Section 1115B.4.1.2. 88" WW. ,. a£ARFI.0ORSPyM:g 1 CLEAR R.OOR SPACE DOORPERHirrGQ TOSWINGOVBl t«ra<EDPOKnON OFMANEUVEHNS SP/tCE MANEUVERING SPACE'' fa) CLEARANCES AT WATBt CLOSET 9. Show that grab bars comply with the following, per Section 1115B.4.1: a) They shall be securely attached 33" above the floor, and parallel and not 36". NOTE: Where a tank-type toilet is used which obstructs placement ofthe rear grab bar at 33", the rear grab bar only may be installed as high as 36". To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes • No • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad 12-0517 4/2/12 ^DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 12-0517 PREPARED BY: Doug Moody DATE: 4/2/12 BUILDING ADDRESS: 2641 Gateway Rd Suite 101 BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VB BUILDING PORTION AREA (Sq.Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Tl 1468 50.30 73,840 Air Conditioning Fire Sprinklers TOTAL VALUE 73,840 Jurisdiction Code cb By Ordinance Bldg. Permt Fee by Ordinanoe Plan Qieck Fee by Ordinance Type of Review: [^Repetitive Fee ~ Repeats p] Complete Review • Other j—I Hourly EsGil Fee • Structural Only Hr. @ * $568.22 $369.34 $318.20 Comments: Sheet 1 of 1 macvalue.doc + CITY OF CARLSBAD BUILDING PLANCHECK CHECKLIST QUICK-CHECK/APPROVAL Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov ENGINEERING Plan Check for CB 12-517 Date: 03/30/12 Project Address: 2641 Gateway APN: 213-191-25 Project Description: Tl Pick up Stix Restaurant Valuation: $73,790 ENGINEERING Contact: Kathleen Lawrence Phone: 760-602-2741 Ennail: Kathleen.lawrence@carlsbadca.gov Fax: 760-602-1052 L RESIDENTIAL IZ TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR (<$20,000.00) PLAZA CAMINO REAL CARLSBAD PREMIER OUTLETS COMPLETE OFFICE BUILDING L„ OTHER: PCR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY: KATHLEEN LAWRENCE DATE: 03/30/12 REMARKS: fees paid on CB 07-2908 Community Shopping Center E-36 Notification of Engineering APPROVAL lias been sent to via on Page 1 of 1 REV 4/30/11 CITY O F CARLSBAD STORM WATER COMPLIANCE ASSESSMENT B-24 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov I am applying to the City of Carlsbad for the following type(s) of construction permit: a^uilding Permit • Right-of-Way Permit • My project is categorically EXEMPT from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it only requires issuance of one or more of the following permit types: Electrical Fire Additional Fire Alarm Fixed Systems Mechanical Mobile Home Plumbing Patio/Deck Photo Voltaic Re-Roofing Sign Spa-Factory Sprinkler Water Discharge Project Storm Water Threat Assessment Criteria* No Thr^t Assessment Criteria My project qualifies as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it meets the "no threat" assessment criteria on the City's Project Threat Assessment Worl<sheet for Determination of Construction SWPPP Tier Level. IVIy project does not meet any of the High, Moderate or Low Threat criteria described below. Tier 1 ^ow Threat Assessment Criteria " My project does not meet any of the Significant or Moderate Threat criteria, is not an exempt permit type (See list above) and the project meets one or more of the following criteria: • Results in some soil disturbance; and/or • Includes outdoor construction activities (such as saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stocl<piling). r/ef2 - Moderate Threat Assessment Criteria • My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria: • Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 ofthe Carlsbad Municipal Code); or, • Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and project meets one or more ofthe additional following criteria: • Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or • Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or • Disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse, and/or • Construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). r/er3 - Significant Threat Assessment Criteria • My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or • My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, refueling and maintenance areas: or, • My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s). / certify to the best of my knowledge that the above checked statements are true and correct. I understand and acknowledge that even though this project does not require preparation ofa construction SWPP, I must still adhere to, and at all times during construction activities for the permit type(s) check above comply with the storm water best management practices pursuant to Title 15 ofthe Carlsbad Municipal Code and to City Standards. *The City Engineer may authorize minor variances from the Storm Water Threat Assessment Criteria in special circumstances where it can be shown that a lesser or higher Constmction SWPPP Tier Level is wan'anted. Project Address: Assessor Parcel No. J^G^/ lirATEuJi^-/ ftp. ^/(?i Owner/Owner's Authorized Agent Name: 1 I?Ar^ CC/AJ£. Title: Owne^VO^g^^^^^^^^^^^^^re^ Date: . City Conciii™ce: //Byr-/r Bate:/ B-24 Page 1 of 1 Rev.03/09 CITY OF STORM WATER Development Services Land Development Engineering CITY OF STANDARDS Development Services Land Development Engineering CITY OF QUESTIONNAIRE 1635 Faraday Avenue CARLSBAD ' E-34 760-602-2750 www.carlsbadca.gov INSTRUCTIONS: To address post-development pollutants that may be generated from development projects, the City requires that new development and significant redevelopment priority projects incorporate Permanent Storm Water Best Management Practices (BMP's) into the project design per the City's Standard Urban Stormwater Management Plan (SUSMP). Initially this questionnaire must be completed by the applicant in advance of submitting for a development application (subdivision, discretionary permits and/or construction permits). The results of the questionnaire determine the level of storm water standards that must be applied to a proposed development or redevelopment project. Depending on the outcome, your project will either be subject to 'Standard Stormwater Requirements' or be subject additional criteria called 'Priority Development Project Requirements'. Many aspects of project site design are dependent upon the storm water standards applied to a project. Applicant responses to the questionnaire represent an initial assessment of the proposed project conditions and impacts. City staff has responsibility for making the final assessment after submission of the development application. If staff determines that the questionnaire was incorrectly filled out and is subject to more stringent storm water standards than initially assessed by the applicant, this will result in the return of the development application as incomplete. In this case, please make the changes to the questionnaire and resubmit to the City. If applicants are unsure about the meaning of a question or need help in determining how to respond to one or more of the questions, they are advised to seek assistance from Land Development Engineering staff. A separate completed and signed questionnaire must be submitted for each new development application submission. Only one completed and signed questionnaire is required when multiple development applications for the same project are submitted concurrently. In addition to this questionnaire, applicants for construction permits must also complete, sign and submit a Project Threat Assessment Form to address construction aspects of the project. Please answer tlie questions below, follow the instructions and sign the form at the end. 1. Is your project a significant redevelopment? DEFINITION: Significant redevelopment is defined as the creation, addition or replacement of at least 5,000 square feet of impervious surface on an already existing developed site. significant redevelopment includes, but is not limited to: the expansion of a building footprint; addition to or replacement of a structure; structural development including an increase in gross floor area and/or exterior construction remodeling; replacement of an impen/ious surface that is not part of a routine maintenance activity; and land disturbing activities related with structural or impervious surfaces. Replacement of impervious sudaces includes any activity that is not part of a routine maintenance activity where impervious matenal(s) are removed, exposing underlying soil during construction. If your project IS considered significant redevelopment, then please skip Section 1 and proceed with Section 2. If your project IS NOT considered significant redevelopment, then please proceed to Section 1. E-34 Pagel of3 REV4/30/10 CARLSBAD STORM WATER STANDARDS QUESTIONNAIRE E-34 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov SECTION 1 NEW DEVELOPMENT PRIORITY PROJECT TYPE Does you project meet one or more of the following criteria: YES NO 1. Housina subdivisions of 10 or more dwellina condominium and apartments units. Examples: single family homes, multi-family homes, 2. Commercial - areater than 1-acre. Any development other than heavy Industry or residential. Examples: hospitals; laboratories and other medical facilities; educational institutions; recreational facilities; municipal facilities; commercial nurseries; multi-apartment buildings; car wash facilities; mini-malls and other business complexes; shopping malls; hotels; office buildings; public warehouses; automotive dealerships; airfields; and other light industrial facilities. 3. Heavv Industrial / Industrv- areater than 1 acre. Examples: manufacturing plants, food processing plants, metal working facilities, printing plants, and fleet storage areas (bus, truck, etc.). 4. Automotive repair shop. A facility categorized in any one of Standard Industrial Classification (SIC) codes 5013, 5014, 5541, 7532-7534, and 7536-7539 5. Restaurants. Any facility that sells prepared foods and drinks for consumption, including stationary lunch counters and refreshment stands selling prepared foods and drinks for immediate consumption (SIC code 5812), where the land area for development is greater than 5,000 square feet. Restaurants where land development is less than 5,000 square feet shall meet all SUSMP requirements except for structural treatment BMP and numeric sizing criteria requirements and hydromodification requirements. 6. Hillside development. Any development that creates 5,000 square feet of impervious surface and is located in an area with known erosive soil conditions, where the development will grade on any natural slope that is twenty-five percent (25%) or greater. 7. EnvirorimentallY Sensitive Area (ESA)\ All development located within or directly adjacent^ to or discharging directly"' to an ESA (where discharges from the development or redevelopment will enter receiving waters within the ESA), which either creates 2,500 square feet of impervious surface on a proposed project site or increases the area of imperviousness of a proposed project site to 10% or more of its naturally occurring condition. 8. Parkina lot. Area of 5,000 square feet or more, or with 15 or more parking spaces, and potentially exposed to urban runoff 9. Sfreefs. roads, hiahwavs, and freewavs. Any paved surface that is 5,000 square feet or greater used for the transportation of automobiles, trucks, motorcycles, and other vehicles 10. Retail Gasoline Outlets. Serving more than 100 vehicles per day and greater than 5,000 square feet 11. Coastal Development Zone. Anv project located within 200 feet of the Pacific Ocean and (1) creates more than 2500 square feet of impermeable surface or (2) increases impermeable surface on property by more than 10%. i7 12. More than 1-acre of disturbance. Project results in the disturbance of more than 1-acre or more of land and is considered a Pollutant-generating Development Project". 1 Environmentally Sensitive Areas include but are not limited to all Clean Water Act Section 303(d) impaired water bodies; areas designated as Areas of Special Biological Significance by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); water bodies designated with the RARE beneficial use by the State Water Resources Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); areas designated as preserves or their equivalent under the Multi Species Conservation Program within the Cities and County of San Diego; and any other equivalent environmentally sensitive areas which have been identified by the Copermittees. 2 "Directly adjacent" means situated within 200 feet of the Environmentally Sensitive Area. 3 "Discharging directly to" means outflow from a drainage conveyance system that is composed entirely of flows from the subject development or redevelopment site, and not commingled with flow from adjacent lands. 4 Pollutant-generating Development Projects are those projects that generate pollutants at levels greater than background levels. In general, these include all projects that contribute to an exceedance to an impaired water body or which create new impervious surfaces greater than 5000 square feet and/or introduce new landscaping areas that require routine use of fertilizers and pesticides. In most cases linear pathway projects that are for infrequent vehicle use, such as emergency or maintenance access, or for pedestrian or bicycle use, are not considered Pollutant-generating Development Projects if they are built with pervious surfaces or if they sheet flow to surrounding pervious surfaces. Section 1 Results: .If you answered YES to ANY of the questions above your project is subject to Priority Development Project requirements. Please check the "meets PRIORITY DEVELOPMENT PROJECT requirements" box in Section 3. A Storm Water Management Plan, prepared in accordance with City Storm Water Standards, must be submitted at time of application. If you answered NO to ALL of the questions above, then your project is subject to Standard Stormwater Requirements. Please check the "does not meet PDP requirements" box in Section 3. E-34 Page 2 of 3 REV 4/30/10 CITY OF CARLSBAD STORM WATER STANDARDS QUESTIONNAIRE E-34 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov SECTION 2 SIGNIFICANT REDEVELOPMENT Complete the questions below regarding your redevelopment project: YES NO 1. Project results in the disturbance of more than 1 -acre or more of land and is considered a Pollutant-generating Development Project (see definition in Section 1). If you answered NO, please proceed to question 2. If you answered YES, then you ARE a significant redevelopment and you ARE subject to PRIORITY DEVELOPMENT PROJECT requirements. Please check the "meets PRIORITY DEVELOPMENT PROJECT requirements" box in Section 3 below. 2. Is the project redeveloping an existing priority project type? (Priority projects are defined in Section 1) 1 If you answered YES, please proceed to question 3. If you answered NO, then you ARE NOT a significant redevelopment and your project is subject to STANDARD STORMWATER REQUIREMENTS. Please check the "does not meet PDP requirements" box in Section 3 below. 3. Is the proiect solelv limited to iust one of the followinq: a. Trenching and resurfacing associated with utility work? b. Resurfacing and reconfiguring existing surface parking lots? c. New sidewalk construction, pedestrian ramps, or bike lane on public and/or private existing roads? d. Replacement of existing damaged pavement? If you answered NO to ALL of the questions, then proceed to question 4. Ifyou answered YES to ANY ofthe questions then you ARE NOT a significant redevelopment and your project is subject to Standard Stormwater Requirements. Please check the "does not meet PDP requirements" box in Section 3 below. 4. Will your redevelopment project create, replace, or add at least 5,000 square feet of impervious surfaces on an existing development or, be located within 200 feet ofthe Pacific Ocean and (1)create more than 2500 square feet of impermeable surface or (2) increases impermeable surface on the property by more than 10%? If you answered YES, you ARE a significant redevelopment, and you ARE subject to PRIORITY DEVELOPMENT PROJECT requirements. Please check the "meets PRIORITY DEVELOPMENT PROJECT requirements" box in Section 3 below. If you answered NO, then you ARE NOT a significant redevelopment and your project is subject to STANDARD STORMWATER REQUIREMENTS. Please check the "does not meet PDP requirements" box in Section 3 below. SECTION 3 Questionnaire Results: fy project meets PRIORITY DEVELOPMENT PROJECT (PDP) requirements and must comply with additional stormwater criteria er the SUSMP and must prepare a Storm Water Management Plan for submittal at time of application. y project does not meet PDP requirements and must only comply with STANDARD STORMWATER REQUIREMENTS per the SUSMP. Applicant Information and Signature Box Address: Assessor's Parcel Number(s): c9'3 /")] Applicant Name: / Applicant Title: Date: y This Box for Cib^M^e Oniy Project ID: E-34 Page 3 of 3 REV 4/30/10 ^ PLANNING DIVISION Development Services <|Y BUILDING PLAN CHECK Planning Division ^ CITY OF REVIEW CHECKLIST 1535 Faraday Avenue (760) 602-4610 www.carlsbadca.gov CARLSBAD P-28 Plan Check No. CB120517 Address 2641 GATEWAY RD Date-emttg Review 3 Planner GINA RUIZ Phone (760) 602- 4675 APN: 213-191-25-00 ^[^j/ld- Type of Project & Use: H Net Project Density: DU/AC Zoning: P^C General Plan: RH/L/CF Facilities Management Zone: 17 CFD (in/out) # 1 Date of participation:03/11/2003 Remaining net dev acres: (For non-residential development: Type of land use created by this permit: ) REVIEW #: . 12 3 Legend: |3 Item Complete ( • item Incomplete - Needs your action • • Environmental Review Required:^^ YES • NO ^ TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: ^ • • Discretionary Action Required: YES • NO ^ TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: • • Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES • NO M CA Coastal Commission Authority? YES Q NO M If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): • • Habitat Management Plan Data Entry Completed? YES • NO |EI If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar. Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) • • Inclusionary Housing Fee required: YES • NO |EI (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES • NO • (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) • • Housing Tracking Form (form P-20) completed: YES • NO • N/A ^ p-28 Page 1 of 2 07/11 Site Plan: Policy 44 - Neighborhood Architectural Design Guidelines ^ • • 1. Applicability: YES • NO ^ ^ • • 2. Project complies: YES • NO^ • • Zoning: 1. Setbacks: Front: Interior Side: Street Side: Rear: Top of slope: Required Required Required Required Required Shown Shown Shown Shown Shown • • 2. Accessory structure setbacks: Front: Required Interior Side: Required Street Side: Required Rear: Required Structure separation: Required Shown Shown Shown Shown Shown • • 3. Lot Coverage: Required Shown • • 4. Height: Required Shown • • • Spaces Required Shown 5. Parking: (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments #tr\S IHhkb KOOl- MaDNTEP-*='^i uPMFMH-PRePeSED AS PART OF THIS TCNANTHW!PROVEIVrENTr-SPE€iriCALLY. THE EQUIPMENT SHOWN M-fe^ ON- SHEET M 1?-t£-Sa PLEASE PROVIDE GCCTIONG 01 lOWING HOW THE-RQQF MGiJNTED EQUIPMENT WH=t=-bfc &UKbhNbD~FROM-V1CW PROM-A<=L STREETS WITI IIN SOO rccT. OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER* DATE Carlsbad Fire Department BLDG. UEPT COPY ......jai-^ Plan Review Requirements Category: TI, COMM Date of Report: 04-23-2012 Name: Address: CLINE DAN 18572 AVOLINDA DR YORBA LINDA CA 92886 Reviewed by: Permit #: CBl20517 Job Name: PICK UP STIX-1468 SF RETAIL TO Job Address: 2641 GATEWAY RD CBAD St: 101 •INCOMPLETE Thc item you have submitted for review io incomplete. At this timo, this office cannot— adequately conduct a review^ to determine compliance with the applicable codes and/or standards. Please review • carefully all comments attached. Please resubmit tho necessary plans and/or specifications, with changes "clouded", to this office for review and approval. • Conditions: Cond: CON0005374 [MET] APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 04/23/2012 By: df Action: AP RECOMMENDED FOR APPROVAL BLDG. DEPT COPY Daryl K. James & Associates, Inc. 205 Colina Terrace Vista, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net Page: 1 of /' Checked by: Anne Marie Bland Date: April 16. 2012 APPLICANT: Dan Cline Architecture PROJECT NAME: Pick Up Stix JURISDICTION: Carlsbad Fire Department PROJECT ADDRESS: 2641 Gateway Ste. 101 PROJECT DESCRIPTION: CB120517 Tenant Improvement INSTRUCTIONS This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. Corrections or modifications to the plans must be clouded and provided with numbered deltas and revision dates along with a descriptive narrative of corrections addressing all comments. Please direct any questions regarding this review to: Anne Marie Bland 760-434-7885 or ambland@pacbell.net CORRECTED PLANS, DESCRIPTIVE NARRATIVE OF REVISIONS FOLLOWING EACH COMMENT ON THIS FORM, AND A COPY OF BUILDING DEPARTMENT (EsGil) COMMENTS MUST BE SUBMITTED DIRECTLY TO: ANNE MARIE BLAND 4380 CARMEL DRIVE CARLSBAD, CA 92010 COMMENTS 4/9/12 - emailed comments to: dan [dan@danclineinc.com] T1 Title Sheet General Notes lAmend note 20 to 2070 CBC. Fire Notes VAmend note 8 to 20 or more. Site Plan ^lNote occupancy classification of adjacent tenant space. Separation may be required per CBC Table 508.4. Under Separate Permit lAdd kitchen hood suppression system to list. Al Floor Plan Door Notes VMain exit door may be provided with locking hardware keyed from the egress side. Locking device must be readily distinguishable as being locked by use of an indicating window incorporated into the locking device. Add description of locking device on main exit door. fSecondary exit door to the rear of the suite must be equipped with locking hardware not requiring a key to exit. RE: lever type, panic hardware. Sign stating "This door to remain unlocked is not applicable to this door. Provide a description of door locking hardware. M-1 Notes for Grease Duct iRemove reference to OCFA from notes. [Kitchen hood fire suppression system must comply with UL 300. Plans must be submitted to the Carlsbad Fire Department under separate permit. Add this note to the plans. fClass K fire extinguisher must be located in the kitchen within 30 feet of cooking appliances. CORRECTION LIST BLDG. DEPT COPY Daryl K. James & Associates, Inc. 205 Colina Terrace Vista, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net Page: 1 of 2 Checked by: Anne Marie Bland Date: April 9, 2012 APPLICANT: Dan Cline Architecture JURISDICTION: Carlsbad Fire Department PROJECT NAME: Pick Up Stix PROJECT ADDRESS: 2641 Gateway Ste. 101 PROJECT DESCRIPTION: CBl20517 Tenant Improvement INSTRUCTIONS This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. Corrections or modifications to the plans must be clouded and provided with numbered deltas and revision dates along with a descriptive narrative of corrections addressing all comments. Please direct any questions regarding this review to: Anne Marie Bland 760-434-7885 or ambland@pacbell.net CORRECTED PLANS, DESCRIPTIVE NARRATIVE OF REVISIONS FOLLOWING EACH COMMENT ON THIS FORM, AND A COPY OF BUILDING DEPARTMENT (EsGil) COMMENTS MUST BE SUBMITTED DIRECTLY TO: ANNE MARIE BLAND 4380 CARMEL DRIVE CARLSBAD, CA 92010 COMMENTS 4/9/12 - emailed comments to: dan [dan@danclineinc.com] T1 Title Sheet General Notes • Amend note 20 to 2010 CBC. Fire Notes • Amend note 8 to 20 or more. Site Plan • Note occupancy classification of adjacent tenant space. Separation may be required per CBC Table 508.4. Under Separate Permit • Add kitchen hood suppression system to list. A1 Floor Plan Door Notes • Main exit door may be provided with locking hardware keyed from the egress side. Locking device must be readily distinguishable as being locked by use of an indicating window incorporated into the locking device. Add description of locking device on main exit door. • Secondary exit door to the rear of the suite must be equipped with locking hardware not requiring a key to exit. RE: lever type, panic hardware. Sign stating "This door to remain unlocked is not applicable to this door. Provide a description of door locking hardware. M-1 Notes for Grease Duct • Remove reference to OCFA from notes. • Kitchen hood fire suppression system must comply with UL 300. Plans must be submitted to the Carlsbad Fire Department under separate permit. Add this note to the plans. • Class K fire extinguisher must be located in the kitchen within 30 feet of cooking appliances. ^ PLUIVIBING, Develooment Services <Xm^' ELECTRICAL, Building Division ^ CITY OF MECHANICAL iess Faraday Avenue CARLSBAD ^^^^ ^www.carlsbadca.gov Project Address: Permit No.: Information provided below refers to worb being done on the above mentioned permit only. This form must be completed and returned to the Building Division before the permit can be issued. Building Dept. Fax: (760) 602-8558 Number of new or relocated fixtures, traps, or floor drains ^ / New building sewer line? Ves No Number of new roof drains? Install/alter water line? Number of new water heaters? / Number of new, relocated or replaced gas outlets? ^ Number of new hose bibs? O Residential Permits: New/expanded service: Number of new amps: Minor Remodel only. Ves No Commercial/Industrial: Tenant Improvement: Number of existing amps Involved in this project: Number of new amps involved in this project: New Construction: Amps per Panel: Single Phase Number of new amperes Three Phase Number of new amperes Three Phase 480 Number of new amperes Number of new furnaces, A/C, or heat pumps? ^ New or relocated duct worb? Ves \/^ No Number of new fireplaces? Number of new exhaust fans? ^ Relocate/install vent? / Number of new exhaust hoods? ^ Number of new boilers or compressors? Number of HP (7^ B-18 Page 1 of 1 Rev. 03/09 INDUSTRIAL WASTEWATER DISCHARGE PERMIT / SCREENING SURVEY Date ^/z^lil. Business Name /^l OkC ^TJxC Street Address ZM/ ^^^r^^l^e^jt^^ rUP. **^IOl Email Address T7/V*J^ P>/^U OO/U^ JUC C&/vi PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Checl< all below that are present at your facility: Acid Cleaning Ink Manufacturing Nutritional Supplement/ Assembly Laboratory Vitamin Manufacturing Automotive Repair Machining/Milling Painting/Finishing Battery IVlanufacturing Manufacturing Paint Manufacturing Biofuei Manufacturing Membrane Manufacturing Personal Care Products Biotech Laboratory (i.e. water filter membranes) Manufacturing Bulk Chemical Storage Metal Casting / Forming Pesticide Manufacturing / Car Wash Metal Fabrication Packaging Chemical Manufacturing Metal Finishing Pharmaceutical Manufacturing Chemical Purification Electroplating (including precursors) Dry Cleaning Electroless plating Porcelain Enameling Electrical Component Anodizing Power Generation Manufacturing Coating (i.e. phosphating) Print Shop Fertilizer Manufacturing Chemical Etching / Milling Research and Development Fiim / X-ray Processing Printed Circuit Board Rubber Manufacturing Food Processing Manufacturing Semiconductor Manufacturing Glass Manufacturing Metal Powders Forming Soap / Detergent Manufacturing Industrial Laundry Waste Treatment / Storage SIC Code(s) (if known): Brief description of business activities (Production / Manufacturing Operations): Description of operations generating wastewater (discharged to sewer, hauled or evaporated): Estimated volume of industrial wastewater to be discharged (gal / day): List hazardous wastes generated (type / volume): Date operation began/or will begin at this location: Have you appjied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes (N9) If yes, when: Site Contact 6 Title firt^L CU-irecZ Signature ENCINA WASTEWATER AUTHORITY, 6200 Avenida Encinas FAX: (760)476-9852 Phone No. HH 3 (<'^ ncinas Carlsbad, CA 92011 (760)438-3941 SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HV# BP DATE / / Business Name Business Contact Telephone # i \ Proiect Addrest J. City State Zip Code APN# Mailing Address ' City state Zip Code Plan File# Project Contact / Telephone # « ^ PARTI The following questions represent the facility's activities, NOT the specific project description. FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business will use, process, or store any of the followmg hazardous materials. If any of the items are circled,^pplicant must contact the Fire Protection Agency with IH€>D Occupancy Rating: Occupancy Rating: 13. Corrosives 14. Otiner Health Hazards 15. None of These. jurisdiction priorto plan submittal. Facility's Square Footage (including proposed project): 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 4. Flammable Solids 8. Unstable Reactives 12. Radioactives PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Ave., Suite 110, San Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED. Project Completion Date: Expected Date of Occupancy: • CalARP Exempt 1 Date Initials • CalARP Required I Date Initials • CalARP Complete I Date Initials YES NO (for new construction or remodeling projects) 1. • [3^ Is your business listed on the reverse side of this form? (checi< all that apply). 2. • H^Will your business dispose of Hazardous Substances or Medical Waste in any amount? 3. • Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds ^200 cubic feet, or carcinogens/reproductive toxins in any quantity? 4. • IH/Will your business use an existing or install an underground storage tank? 5. • [B/Will your business store or handle Regulated Substances (CalARP)? 6. • E'/Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? 7. • \Ei Will your business store petroleum in tanl<s or containers at your facility with a total storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demoiition permit. Note: if the answer to questions 4 or 5 is yes, applicant must aiso submit an asbestos notification form to the APCD at least 10 worl<ing days prior to commencing demolition or renovation, except demolition or renovation of residential structures of four units or less. Contact the APCD for more information. YES NO^ 1. D 0 Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at http://www.sdapcd.org/info/facts/permits.pdf, and the list of typical equipment requiring an APCD permit on the reverse side _^7°^ ''^'^ Contact APCD if you have any questions). 2. • 10 (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? (Search the California School Directory at http://www.cde.ca.qov/re/sd/ for public and private schools or contact the appropriate school district). EyMas a survey been performed to determine the presence of Asbestos Containing Materials? \Sfy^\\\ there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos? ]Vj Will there be demolition involving the removal of a load supporting structural member? • • • Briefly describe business activities: Briefly describe proposed project: I declare 1 Name of ( uftderTrenaJJt^ofaerjufy tjaet to the best of my knowledge and belisfithesEsoanss^madeiifere Owner or /Authorized Agent Signature ofOwner or Authorized Agent rein are true and correct. ^ I 25. I It. Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:. BY: FOR OFFICIAL USE ONLY: DATE: EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD APCD COUNTY-HMD APCD COUNTY-HMD APCD *A stamp in this box onlv exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. HM-9171 (02/11) County of San Diego - DEH - Hazardous Materials Division C\?|20S'/7 PROIECT NUM3ES CARLSBAD FIRE DEPARTMENT EXPEDITED PLAN CHECK REQUEST I, *J 7^'CITKJ^ am requesting 'Expedited Plan Check Services' and understand I will be levied an additional fee assessed at the rate of $90.00 dollars per hour plus $25.00 dollars administration fee. I understand that my plans shall not be released until all fees are paid. I, t7^^^ the applicant, am solely responsible for all fees due should the project be withdrawn or otherwise not completed. And by signing below I acknowledge that my plans shall be forwarded by the City of Carlsbad to an independent contractor/consultant. _acknowledge that the 'first review' time for all expedited Fire plan reviews will be fourteen- (14) business days from date of submittal. These additional day account for acceptance and delivery of your plans and then the parcel return to our office if recommended for approval. the applicant, acknowledges that corrected or revised plans shall be sent directiv to the plan checker, at the address specified on the Correction List, at my cost, parcel post or other means. P6-C _ acknowledge that a turn-around time for re-submittals is seven- (7) business days from the date plans are received at the address specified by the plan checker on the Correction List. Once all corrections are made, your plans are then returned to the Carlsbad Fire Department with a "Recommendation for Aoproval" based solely on the adopted Codes and Standards. This is not a full approval. Your plans are then forwarded to the Carlsbad Fire Department, and once your plans are received by our office they are subject to an additional review to ensure conformance with Carlsbad Municipal Code. This additional review is subject to an additional review period of seven- (7) days from date that we receive the plans from the plan reviewer. The Carlsbad Fire Department does not perform 'Over-the-counter' plan review services. Plans submitted to the Carlsbad Fire Department for review by CFD staff shall be checked on a 'first come, first served' basis and could take 60 days or more to be completed. PLEASE CIRCLE YOUR SELECTION Applicant Signature_ Copy to Building and Fire Prevention file NO Date Revised 11/07/2011 K) m o > C C "D o es O (Jl I- 73 m > r-m o s m 3) o m Tl O 5 07-19-2012 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No:PCR12058 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Vaiuation: Reference #: PC #: Project Title: 2641 GATEWAY RD CBAD St: 101 PCR 2131912.500 Lot#: 0 $0.00 Construction Type: 5A CB12-517 PICK UP STIX PLUMBING, MECHINICAL, ELECTRICAL Status Applied Entered By Plan Approved Issued Inspect Area ISSUED 06/20/2012 MDP 07/19/2012 07/19/2012 Applicant: SEAN PARDIS 714 744-2446 Owner: REGENCY BRESSI LLC C/O CORNERSTONE REAL ESTATE ADVIS 100 WILSHIRE BLVD #700 SANTA MONICA CA 90401 Plan Check Revision Fee Fire Expedited Plan Review Additional Fees $215.00 $0.00 $0.00 Total Fees: $215.00 Total Payments To Date: $215.00 BalanceDue: $0.00 Inspector: FINALAPPROVAL Date: Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions," You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad IVIunicipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul theii imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY fo water and sewer connection fees and capacity Changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any tees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously othenwise expired. ^ CITY OF CARLSBAD PLAN CHECK REVISION APPLICATION B-15 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Plan Check Revision No. _Onginal Plan Check No. Project Address Z.'^H 1 (^oA^^tiJ Date G/ZQ^/^ Contact Contact Address. . Email General Scope of Work. -City. Zip. Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 Elements revised: I^PIans • Calculations • Soils • Energy • Other 2 Describe revisions in detail 3 List page(s) where each revision is shown 4 List revised sheets that replace existing sheets ^ V 1 * ' 1 * jl—™" f y 5 Does this revision, in any way, alter the exterior of the project? O Yes 6 Does this revision add ANY new floor area(s)? • Yes • No T Does this revision affect any fire related issues? Q Yes |^ No 8 Is this a complete set? • Yes ^ No No ^Signature 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: 760-602-2717/2718/2719 www.carlsbadca.gov Fax: 760-602-8558 EsGil Corporation In (Partners fii-p with government for cBuiCtCing Safety DATE: 7/17/12 __J3-^^peLICANT JURISDICTION: City OfCarlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 12-0517 PCR12-058 SET: III PROJECT ADDRESS: 2641 Gateway Rd Suite 101 PROJECT NAME: Pick up Stix - TI XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to fonward to the applicant contact person. I I The applicant's copy of the check list has been sent to: IXI EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person • REMARKS: By: Doug Moody Enclosures: EsGil Corporation • GA • EJ • PC 7/17/12 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In Partnership with government for (BuiCding Safety DATE: 7/11/12 • APPLIQANT 4 JURIS/^ JURISDICTION: City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 12-0517 PCR12-058 SET: II PROJECT ADDRESS: 2641 Gateway Rd Suite 101 PROJECT NAME: Pick up Stix - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. X The applicant's copy of the check list has been sent to: 1) Sean Pardis 2641 Gateway Rd Suite 101, Carlsbad, CA 92008 2) Dan Cline e-mail: dan@danclineinc.com phi: 714-315-0099 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. IX EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Sean Pardis Telephone #: 714-744-2446 Date contacted: ^ I'I(by:|o^ ) Email: seanp(S)orchidcfs.com Fax #: 714-744-2447 " C Mail Telephone — Fax-^ In Person • REMARKS: By: Doug Moody Enclosures: EsGil Corporation • GA • EJ • PC 7/2/12 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 12-0517 PCR12-058 7/11/12 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Please revise the plans to show where food or drink is served at a counter exceeding 34" in height for the consumption by customers seated or standing at the counter, a portion of the main counter which is 60" in length minimum shall be provided in compliance with Section 1122B (28" to 34" in height). Show that the minimum strike edge distances are provided at the level area on the side to which a door swings at both exit doors, per Section 1133B.2.4.3: a) >12" on the push side, if the door has both a latch and a closer. Figure 11B-26A. Show that the water closet is located in a space, per Section 1115B.3.2.3, which provides: a) A clear space in front of the water closet measuring 60" wide by 48" in front. Section 1115B.4.1.2. OEARRXKM SPACE OOOfiPCTUnTED (UTCHEO PORTKM 'WWEUVERIWi SPACE'' (a) CLEARANCES AT WATSt ClOSET City of Carlsbad 12-0517 PCR12-058 7/11/12 4. Show that dining facilities are accessible, per Section 1104B.5, as follows: a) Fixed seating, counters and/or tables shall comply with Section 1104B.5.4 as follows: i) Wheelchair access is required to all areas where each type of functional activity occurs. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes • No • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. EsGil Corporation In (partnership with government for (BuiCding Safety DATE: 6/28/12 • APPJJCANT . ETJURIS.^ JURISDICTION: City of Carlsbad ^-Q-ptiAMTrEVlEVVER • FILE PLAN CHECK NO.: 12-0517 PCR12-058 SET: I PROJECT ADDRESS: 2641 Gateway Rd Suite 101 PROJECT NAME: Pick up Stix - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ^ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ^ The applicant's copy of the check list has been sent to: Sean Pardis 2641 Gateway Rd Suite 101, Carlsbad, CA 92008 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. X EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Sean Pardis Telephone #: 714-744-2446 Date contacted: (by: Di^) Email: Fax #: 714-744-2447 Mail Telephone ^ Fax ^ In Person • REMARKS: By: Doug Moody Enclosures: EsGil Corporation • GA • EJ • PC 6/21/12 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 6/28/12 12-0517 PCR12-058 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 12-0517 PCR12-058 JURISDICTION: City ofCarlsbad OCCUPANCY: B USE: Restaurant TYPE OF CONSTRUCTION: VB ACTUAL AREA: 1468sf ALLOWABLE FLOOR AREA: STORIES: 1 HEIGHT: SPRINKLERS?: YES OCCUPANT LOAD: 48 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 3/23/12 DATE PLANS RECEIVED BY ESGIL CORPORATION: 6/21/12 DATE INITIAL PLAN REVIEW COMPLETED: 6/28/12 PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when vou submit the revised plans. City of Carlsbad 12-0517 PCR12-058 6/28/12 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. 1. Please provide a detailed description of the scope of work to be done under this revision to each altered sheet of the plans. Clearly identify on the plan the area of change (cloud, delta etc) Indicate all existing building, plumbing, electrical and mechanical components which are to be revised and clearly define the method of showing compliance with the current building codes adopted by the jurisdiction without this information a review can not be done. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes • No • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. Ifyou have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad 12-0517 PCR12-058 6/28/12 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE PLAN CHECK NO.: 12-0517 PCR12-JURISDICTION: City of Carlsbad 058 PREPARED BY: Doug Moody DATE: 6/28/12 BUILDING ADDRESS: 2641 Gateway Rd Suite 101 BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VB BUILDING PORTION AREA ( Sq. Ft.) Valu ation Multiplier Reg. Mod. VALUE ($) Revision Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinanoe Plan Check Fee by Ordinance Type of Review: ^Repetitive Fee ~ Repeats • Complete Review • Other 0 Hourly EsGil Fee $215.00 • Structural Only $86.00 Hrs. $172.00 Based on hourly rate Comments: Sheet 1 of 1 macvalue.doc + C :d S —*»— lit 3| ill gs 1*1 • X o o f S _-z>rno zcom co^OoO-a CO m m -n O 73 H -< O > o m > 5 o < ^ m X H m O I |— f- _co 0) H o m Tl 7J o z > z D O O O 73 Ui 73 m > z w z m m m ^ f 2 O I m O m 5; 73 m w H m 73 m > r- W H C D m 73 01 00 i > UJ O > 73 O O < m TJ CO I CO 01 — 00 n o > o z > n m , > O I r- mr-co- HO 73m 1-01 CO 00 u coF — i— b mTJ COD m S73 o> 73; m D c > CO cn 00 i •-2' LO AL AL i~ > 1 GO 1 r" -< FR-m FR-lOL > lOL 1— 1 ' 1 0 CD m —n ' 1 Tl > 0 I ^ d 4^ ^ r < o cc I-o UJ s 00 If) o CM si D. Q. o v3 9 1^ OQ C3-