HomeMy WebLinkAbout2641 HANCOCK CIR; ; CB041680; Permit--~ .. -------··-,
i 0~::004; tr. 1636~~;;:{n:i~:~;-Pannn No CB041680
"' ' Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
08/25/2004
,.l/o'fl ":t6si HANCOCK CR CBAD
RESDNTL Sub Type:
Lot#: €131900100
$814, 187,00 Construc1ion Type:
Reference #:
CONDO
0
VN
CT030003
Status:
Applied:
Entered By:
ISSUED
09/25/2003
AMA
Plan Approved:
# Dwelling Units: 1 O Structure Type: MF5+ Issued: 08/25/2004
Bedrooms: 24 Bathrooms: 14 Inspect Area:
Project Title: MULBERRY-BRESSI AFFORD-BLDG 1
9225 SF,3893 SF GAR,818 SF DECKS
Applicant:
BRESSI GARDEN LANE LLC
5780 FLEET ST 92008
760 918-7765
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Pot Water Con. Fee
Meter Size
Add'I Pot Water Con, Fee
RecL Water Con, Fee
$2,600,71
$0,00
$1,690.46
$0,00
$0,00
$81.42
$18,250,00
$0,00
$0,00
$0,00
$0,00
$0,00
$0,00
$0,00
$0,00
$0,00
$29,990,00
D5/8
$0,00
$0,00
Orig PC#: PC030049
Plan Check#: PC030049
Owner:
BRESSI GARDEN LANE LLC
5780 FLEET ST 92008
760 918-7765
Meter Size
Add'I RecL Water Con, Fee
Meter Fee
SDCWAFee
CFD Payoff Fee
PFF
PFF (CFD Fund)
License Tax
License Tax (CFD Fund)
Traffic Impact Fee
Traffic Impact (CFD Fund)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnlieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
TOTAL PERMIT FEES
$0,00
$1,400,00
$20,040,00
$21,269,50
$14,818,20
$0,00
$0,00
$0,00
$5,280,00
$0,00
$0,00
$1,080,00
$260,00
$261,00
$0,00
$0,00
$0,00
$0,00
$17,350,00
$200,00
$134,571.29
Total Fees: $134,571,29 Total Payments To Date: $0,00 Balance Due: $134,571,29
9725 08/25/ 04 0002 01
CGP
02
134571-29
ln,$p ~ct ion List
' ,
Permit#: CB041680 Type: RESDNTL CONDO MULBERRY-BRESSI AFFORD-BLDG 1
9225 SF,3893 SF GAR,818 SF DECKS -263
Date lnseectlon Item lnseector Act Comments
05/02/2005 89 Final Combo PC AP WAITING ON ENGR. APPROVAL
04/15/2005 89 Final Combo PC PA F.D. & ENGR DEPT. APPROVALS OK.
GAS METER RELEASE
04/14/2005 89 Final Combo PC co 1 )STAIR TO UNIT 8 & 4 6 & 9 SECURE
POS. CONN. 2) ATTACH ANTI-TIP@
STUB 3) INSTALL ALL ADDRESSES
04/12/2005 23 Gas/TesVRepairs PC AP ALL UNITS
04/08/2005 39 Final Electrical PC AP EMA@ 2633, 2635, 2639, 2641, 2645,
2647, 2649 AND HOUSE 2631, 2637,
2643, AND HOUSE
03/23/2005 11 Fig/Foundation/Piers PC AP STREET LIGHT & BONDING
03/23/2005 31 Underground/Conduit-Wirin PC AP
03/07/2005 17 Interior Lath/Drywall PC AP BOTH FLOORS & GARAGES
03/03/2005 16 Insulation PC AP UPPER UNITS CONTRACTOR REFUSES
TO HARD PIPE EXH. FAN DUCTS
03/02/2005 16 Insulation PC PA UPPER FLOOR UNITS ONLY
03/01/2005 16 Insulation PC NA HARD PIPE EX. FANS TO OUTSIDE
WHERE IT PENETRATES 1-HR CEILING
02/17/2005 18 Exterior Lath/Drywall PC AP
02/17/2005 84 Rough Combo PC AP CHECK ALL FIRE CAULK @ INSUL.
INSP. • FIRE DAMPERS IN@ INSP
02/16/2005 18 Exterior Lath/Drywall PC co CAULKING, CORNER AID, LATH NAILS
02/16/2005 23 Gas/TesVRepairs PC NA
02/16/2005 24 Rough/Topout PC AP
02/16/2005 27 Shower Pan/Roman Tubs PC AP
02/07/2005 18 Exterior Lath/Drywall PC NA
01/19/2005 14 Frame/Steel/Bolting/Weldin PC PA PRELIM DW, INSUL VERIFY BEARING
OF FLA JOISTS, ROOF TRUSSES AT
METAL STUDS, AND CUT OUT OF
HEADERS FOR AC OUTLETS
12/20/2004 83 Roof Sheathing/Ext Shear PC AP
12/06/2004 14 Frame/Steel/Bolting/Weldin PC PA FLOOR NAILING
11/18/2004 11 Fig/Foundation/Piers PC AP
11/18/2004 31 Underground/Conduit-Wirin PC AP ANDUFER
10/26/2004 21 Underground/Under Floor PC AP
10/26/2004 22 Sewer/Water Service PC AP
10/18/2004 21 Underground/Under Floor PC NA
Friday, September 09, 2005 Page 1 of 1
Clll II Clrllbld
~ ·; Final Buildlng Inspection
O<"Wjl'MO ~
Dept: Building Engineering Planning CMWD St Lite Fire
Plan Check #:
Permit#:
Project Name:
Address:
Contact Person:
Sewer Dist:
PC030049
CB041680
MULBERRY-BRESSI AFFORD-BLDG 1
9225 SF,3893 SF GAR,818 SF DECKS -2631,2633,2635,2
2631 HANCOCK CR Lot:
Phone:
CA Water Dist: CA
Date: 03/17/2005
Permit Type: RESDNTL
Sub Type: CONDO
0
-~;~~~~~ .. ::~~ ............................ ~:~~~~~~: .. ·;;~·;i~·; ..... ~:::~~~~: .... 7 .. :;~~~~:~~~~:·=·
Inspected Date /
By: __________ Inspected: _____ Approved: ___ Disapproved: __
Inspected Date
By: __________ Inspected: _____ Approved: ___ Disapproved: __ ...........................................................................................................................................................
Comments: _____________________________ _
, .
SEP 1 2 2005
Dept: Building Planning CMWD St Lite Fire
Plan Check #: PC030049 Date: 09/09/2005
Permit#: CB041680 Permit Type: RESDNTL
Project Name: MULBERRY-BRESSI AFFORD-BLDG 1 Sub Type: CONDO
9225 SF,3893 SF GAR,818 SF DECKS -2631,2633,2635,2
Address: 2631 HANCOCK CR Lot: 0
Contact Person: Phone:
Sewer Dist: CA Water Dist: CA
I 1111111111111111111111111I11111 Ill I I Ill I Ill 11 I I I I 111 I II I 111111111111111111 I I I I I I I I I I I I I I I 1111111 • 1111 I I 111111 I II I 11111111111111111 I 11111 It I I I I I I 111111111
~;per~ o4aV\J) Date
as-(o;~<; ✓ Inspected: Approved: Disapproved: __
Inspected Date
By: Inspected: Approved: Disapproved: __
Inspected Date
By: Inspected: Approved: Disapproved: __
I I •II Ill I I 111111 II II I I I I 11111 Ill II II 1111111111I I111111111111111 I ll II I I I I I 111 I I II I 1111 I 1111111 I Ill I II 11 I II 111 II Ill I II I 1111111111111 II 11 I I I I I II II I I I II I I I I Ill
Comments: ____________________________ _
City of Carlsbad Bldg Inspection Request
For: 04/08/2005
Permit# CB041680 Inspector Assignment: PC ---
Title: MULBERRY-BRESSI AFFORD-BLDG 1
Description: 9225 SF,3893 SF GAR,818 SF DECKS·
2631,2633,2635,2637,2639,2641,2643,2645,2647 &2649
Type: RESDNTL Sub Type: CONDO
Job Address:
Suite:
Location:
2631 HANCOCK CR
Lot 0
APPLICANT BRESSI GARDEN LANE LLC
Owner:
Remarks:
Total Time:
CD Description Act
19 Eloal Structural >
:Ill Fine I Ph rmiaiRg
39 Flnal Electrlcal
~ Flnal Mceha1,ical
Associated PCRs/CVs
lns11ection HistotY
Date Description Act
03/23/2005 11 Ftg/Founda1ion/Piers AP
03/23/2005 31 Underground/Conduit-Wiring AP
03/07/2005 17 Interior Lath/Drywall AP
03/03/2005 16 Insulation AP
03/02/2005 16 Insulation PA
03/01/2005 16 Insulation NR
02/17/2005 18 Exterior Lath/Drywall AP
02/17/2005 84 Rough Combo AP
02/16/2005 18 Exterior Lath/Drywall co
02/16/2005 23 Gas/T esVRepairs NR
02/16/2005 24 Rough/Topout AP
02/16/2005 27 Shower Pan/Roman Tubs AP
02/07/2005 18 Exterior Lath/Drywall NR
01/19/2005 14 Frame/Steel/Bolting/Welding PA
Phone: 7608016121
Inspector: _L
Requested By: ALEX
Entered By: CHRISTINE
Comment
lnsp
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
PC
'2.kt.f 1 z 'lftt.{5 / UY] TulfCf
M-tJ ,~
BOTH FLOORS & GARAGES
UPPER UNITS CONTRACTOR REFUSES TO HARD PIPE EXH. FAN
DUCTS
UPPER FLOOR UNITS ONLY
HARD PIPE EX. FANS TO OUTSIDE WHERE IT PENETRATES 1-HR
CEILING
CHECK ALL FIRE CAULK @ INSUL. INSP. -FIRE DAMPERS IN @
INSP
CAULKING, CORNER AID, LATH NAILS
PRELIM DW, INSUL VERIFY BEARING OF FLR JOISTS, ROOF
~y~t
SOIL 1, Tlnllf'C!I, 111.'
34245
SOUTHERN CALIFORNIA SOIL & TESTING, INC.
6280 RIVERDALE STREET, POST OFFICE BOX 600627, SAN DIEGO, CA 92160-0627
Phone (619) 280-4321, FAX (619) 280-4717
SCS&T FILE NO .. ~v~"-'~· ·~,Z~3~i~I _____ _
P.O. NO.:_-________ _
C PL NC FIX PAGE_____.l_ OF _J__
FIELD INSPECTION REPORT FOR: • REINFORCED CONCRETE • REINFORCED MASONRY 0 WELDING • FIREPROOFING
• H.S. BOLTING • • a.c. CONCRETE • ROOFING/WATERPROOFING !I P.T. CONCRETE/STRESS • EPOXY ANCHORS
PROJECT TITLE: DSA FILE NO.:
PERMIT NO.:
ENGINEER:
MATERIAL CLASSIFICATION:
DATE: DESCRIPTION OF WORK INSPECTED: TIME ARRIVED:O7c::)6
UBC I hereby certify that I have inspected the above reported work. Unless noted othe11Nise,
the work inspected is to the best of my knowledge in compliance with the approved plans,
specifications and applicable ~ti_gpe-of the governing building laws.
Inspector Initials ~
DSA I hereby certify that I have inspected the above reported work in accordance with the
requirements ot DSA approved documents. Sampling and testing were conducted in
accordance with the requirements of the DSA approved documents. The work inspected
complies with the DSA approved documents.
Yes: __ No: __ Inspector Initials
SCST205 (REV 8/04)
DSA APP. NO.:
PLAN FILE NO.:
TIME DEPARTED: /Cf C, C