Loading...
HomeMy WebLinkAbout2648 WADSWORTH ST; ; CB163170; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 08-26-2016 Residential Permit Permit No: CB163170 Job Address: Building Inspection Request Line (760) 602-2725 2648 WADSWORTH ST CBAD Permit Type: RESDNTL Sub Type: SFD Status: ISSUED Applied: 08/17/2016 Entered By: SLE Parcel No: 2081931400 Lot#: 236 Valuation: $606,601.00 Constuction Type: 58 Occupancy Group: # Dwelling Units: Bedrooms: 1 5 Reference#: CT130003 Structure Type: SFD Bathrooms: 5.5 Plan Approved: 08/26/2016 Issued: 08/26/2016 Inspect Area: PB Orig PC#: PC150042 THE VISTAS: PHASE 4 I PLAN 4 Plan Check#: PC160048 Project Title: 3,897 SF LIV I 432 SF GARAGE I 229 SF PORCH Applicant: TOLL BROTHERS INC 200 725 W TOWN AND COUNTRY RD ORANGE CA 92868 760s720-5485 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Green Bldg Stands Plan Chk Fee $2,358.26 $0.00 $1,650.78 ($500.00) ($132.06) $78.86 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $5,609.00 FS3/4 $0.00 $0.00 $25.00 $0.00 Total Fees: $32,537.22 Total Payments to Date: Owner: RANCHO COSTERA LLC 200 725 W TOWN AND COUNTRY ORANGE CA 92868 760-720-5485 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWA Fee CFO Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnlieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees Fire Sprinkler Fees TOTAL PERMIT FEES $32,537.22 Balance Due: FS3/4 $0.00 $356.00 $4,963.00 $1,723.10 $11,040.14 $0.00 $0.00 $0.00 $2,690.00 $0.00 $0.00 $339.00 $89.00 $144.14 $0.00 $0.00 $0.00 $0.00 $2,103.00 $0.00 $0.00 $32,537.22 $0.00 Inspector: FINAL APPROVAL Date: 2-Z/l ~ 7,,() 17 Clearance: ------ NOTICE: Please take CE that cqroJal r:i ywr p'tjed irdudes the "lrrpa,itiori' r:J fees, dedications, reservations, or cther exactions hereafter cdledively referred to as "fees/exa:tions." You have 9J days frcm the date this perrrit Wif, issued to pretest irrpositia, r:i these fees/exactions. If yw pretest them, yw rrust fdlo.vthe pretest Jl"CXll(ilres set forth in GoJerm-ent Code Sediai 60020(a), and file the IJO!est and any dher reqt.ira:l infooration wth the aty lv'a,ager fcr pucessirg in acxxroa,oo wth Ca1sbal M.nidJ:EI Code Sediai 3.32.030. Faili.re to tirrely fdlo.v that procaire 'hill bar any sub;ecµlnt legal action to atta:k, revielN, set aside, void, cr anrul their in-position. You ae tieret,,, FUm-ER f\OT1Fl8) that your rig,! to pretest the specified fees/exa:tions DCES NOT APPLY to water a,d 'Sel-8 cx:medion fees and ~ty ctianges, ncr planrirg, zonrg, gacirg or cther sinilar appication pucessirg cr service fees in cx:medion wth tns p'tject. t-lR DCES IT APPLY to any . . . . • ·1 t. . . . . City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 08-26-2016 Storm Water Pollution Prevention Plan (SWPPP) Permit Permit No:SW160381 Job Address: Permit Type: 2648 WADSWORTH ST CBAD SW PPP Status: Parcel No: 2081931400 Lot#: 236 Applied: Reference #: CB#: CB163170 Project Title: THE VISTAS: PHASE 4 / PLAN 4 Applicant: TOLL BROTHERS INC 200 725 W TOWN AND COUNTRY RD ORANGE CA 92868 760-720-5485 Emergency Contact: GREG DEACON 760-637-9083 SWPPP Plan Check SWPPP Inspections Additional Fees TOTAL PERMIT FEES Entered By: Issued: Inspect Area: Tier: Priority: Owner: RANCHO COSTERA LLC 200 725 W TOWN AND COUNTRY ORANGE CA 92868 760-720-5485 ISSUED 08/18/2016 SLE 08/26/2016 1 L $0.00 $59.00 $0.00 $59.00 Total Fees: $59.00 Total Payments To Date: $59.00 Balance Due: FINAL APPROVAL DATE 1~z1-u11 ---CLEARANCE SIGNATURE_1. °IJ!A ---- / $0.00 PERMIT INSPECTION HISTORY REPORT (CB163170) Permit Type: BLDG-Residential Application Date: 08/17/2016 Owner: RANCHO COSTERA LLC - INACTIVE Work Class: Single Family Detached Issue Date: 08/26/2016 Subdivision: Status: Closed -Finaled Expiration Date: 05/01/2017 Address: 2648 Wadsworth St Carlsbad, CA IVR Number: 716505 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 11/10/2016 11/10/2016 BLDG-13 Shear 000670-2016 Passed Andy Krogh Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 11/15/2016 11/15/2016 BLDG-84 Rough 001211-2016 Failed Andy Krogh Reinspection Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready ..... need fire sign off No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 11/17/2016 11/17/2016 BLDG-84 Rough 001669-2016 Passed Andy Krogh Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready ..... need fire sign off Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 11/28/2016 11/28/2016 BLDG-17 Interior 003231-2016 Passed Andy Krogh Complete Lath/Drywall BLDG-18 Exterior 002966-2016 Failed Andy Krogh Reinspection Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-23 002965-2016 Passed Andy Krogh Complete Gas/Test/Repairs 11/29/2016 11/29/2016 BLDG-18 Exterior 003509-2016 Passed Andy Krogh Complete Lath/Drywall 01/18/2017 01/18/2017 BLDG-Electric Meter 010023-2017 Passed Jonathan West Complete Release 02/22/2017 02/22/2017 BLDG-Final 014380-2017 Passed Jonathan West Complete Inspection February 22, 2017 Page 1 of 2 Permit Type: Work Class: Status: Scheduled Date February 22, 2017 PERMIT INSPECTION HISTORY REPORT (CB163170) BLDG-Residential Application Date: 08/17/2016 Owner: Single Family Detached Issue Date: 08/26/2016 Subdivision: Closed -Finaled Expiration Date: 05/01/2017 Address: IVR Number: 716505 Actual Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS RANCHO COSTERA LLC - INACTIVE 2648 Wadsworth St Carlsbad, CA Reinspection Passed Yes Yes Yes Yes Yes Complete Page 2 of 2 Inspection List Permit#: CB163170 Type: RESDNTL SFD THE VISTAS: PHASE 4 / PLAN 4 3,897 SF LIV I 432 SF GARAGE I 229 SF P Date ~·· lnsi:,ection Item Inspector Act Comments 10/31/2016 15 Roof/Re roof AEK AP 09/12/2016 11 Ftg/Foundation/Piers AEK AP 09/07/2016 21 Underground/Under Floor AEK AP 09/07/2016 22 Sewer/Water Service AEK AP Friday, February 24, 2017 Page 1 of 1 <_(~') CB163170 2648 WADSWORTH ST THE VISTAS: PHASE 4 / PLAN 4 ~ CITV OF CARLSBAD ,.-Etullding Division INSPECTION RECORD: 3,897 SF LIV/ 432 SF GARAGE/ 229 SF PORCH RESDNTL SFD ( J INSPECTION RECORD CARD WITH APPROVED Lot#: 236 TOLL BROTHERS INC PLANS MUST BE KEPT ON THE JOB 0 CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION RECORD COPY 0 FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.Carlsbadca.gov/Bulldlng AND CLICI( ON "Request Inspection" DATE: r. u. '-,I VV I VL1'..) I 'l/ \rVIL Required Prior to Requesting Building Final If Checked YES Planning/Landscape 760-944-8463 Allow 48 hours CM&I (Engineering lnspectlonsJ 760-438-3891 Call before 2 pm Fire Prevention 7 60-602-46 60 Allow 48 hours REINFORCED STEEL MASONRY PRE GROUT ELECTRIC SERVICE O TEMPORARY 0 GROUT O WALL DRAINS #35 PHOTO VOLTAIC #10 TILT PANELS #39 FINAL #11 POUR STRIPS #11 COLUMN FOOTINGS #41 UNDERGROUND DUCTS & PIPING #14 SUBFRAME D FLOOR O CEILING #44 0 DUCT & PLENUM 0 REF. PIPING #15 ROOFSHEATHING #43 HEAT-AIR COND. SYSTEMS #13 EXT. SHEAR PANELS #49 FINAL #16 INSULATION CODE# COMBO INSPECTION #18 EXTERIOR LATH #81 UNDERGROUND (11,12,21,31) #17 INTERIOR LATH & DRYWALL #82 DRYWALL,EXT LATH, GAS TES (17,18,23) #51 POOL EXCA/STEEL/BOND/FENCE #83 ROOF SHEATJNG, EXT SHEAR (13,15) #84 FRAME ROUGH COMBO (14,24,34,44) #85 T-Bar (14,24,34,44) FINAL OCCUPANCY (19,29,39,49) D SEWER & BL/CO O PL/CO #21 UNDERGROUND OWASTE D WTR #24 TOP OUT D WASTE O WTR A/S UNDERGROUND VISUAL #27 TUB & SHOWER PAN A/S UNDERGROUND HYDRO #23 AS TEST ~AS PIPING A/S UNDERGROUND FLUSH #25 WATER HEATER A/S OVERHEAD VISUAL #28 SOLAR WATER A/S OVERHEAD HYDROSTATIC #29 FINAL A/SFINAL CODI?# STORM WATER F/A ROUGH-IN #600 PRE-CONSTRUCTION MEETING F/A FINAL #603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN 1.605 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST , #607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM ANAL #609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST #610 VERBAL WARNING MEDICAL GAS FINAL REV 10/2012 Date Inspector l-l'is-17 3. \.v(fj Date Ins ector SEE BACK FOR SPECIAL NOTES .. ~-----------------------------------------~d~~'~·-._ Ccityof Carlsbad RESIDENTIAL GREEN BUILDING CODE STANDARDS MANDATORY MEASURES CERTIFICATION CHECKLIST Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov 8-51 This form, signed and completed, and all receipts for the recycled materials shall be submitted to the Building Inspector prior to Final Inspection. Site Development Mandatory . ~ . . . 4.106.2 A plan is developed and implemented to manage storm water drainage during construction. (X) 4.106.3 The site shall be planned and developed to keep surface water away from buildings. (X) Construction plans shall indicate how site grading or a drainage system will manage all surface water flows. Energy Efficiency 4.201.1 Low-rise residential buildings shall meet or exceed the minimum standard design required by the California Energy Standards. (X) Water Efficiency and Conservation ·., r ,....;.-,. .-~ --..-tf . -, ~- Indoor Water Use -· ... ~ n., 4.303.1 Indoor water use shall be reduced by at least 20 percent using one of the following methods: (X) 1. Water saving fixtures or flow restrictors shall be used. 7/01/201 1 2. A 20 percent reduction in baseline water use shall be demonstrated. 4.303.2 When using the calculation method specified in Section 4.303 .1, multiple showerheads shall not (X) exceed maximum flow rates. 7/01/201 1 4.303.3 Plumbing fixtures (water closets and urinals) and fittings (faucets and shower heads) shall (X) comply with specified performance requirements. 7/01/2011 Outdoor Water Use ' 4.304.1 Automatic irrigation systems controllers installed at the time of final inspection shall be weather- based. (X) -Enhanced Durability and Reduced Maintenance 4.406.1 Joints and openings. Annular spaces around pipes, electric cable~. conduits or other openings in plates at exterior walls shall be protected against the passage of rodents by closing such openings (X ) with cement mortar, concrete masonry or similar method acceptable to the enforcing agency. Construction Waste Management Plan 4.408.1 A minimum of 50 percent of the construction waste gen.erated at the site is diverted to recycle or (X) salvage. Recycled material receipts from approved recyclers must be attached to th is form. 4.408.2 Where a local jurisdiction does not have a construction and demolition waste management (X) ordinance, construction waste management plan, per form 8-59, shall be submitted for approval to the enforcinQ aQencv. Bui,lding Maintenance and Operation 4.410.1 An operation and maintenance manual shall be provided to the building occupant or owner. (X) Environmental Quality Fireplac;es .. . . . . 4.503.1 Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed woodstove or pellet stove shall comply with US EPA Phase II emission limits where applicable. Woodstoves, pellet stoves and fireolaces shall also comply with aoolicable local ordinances. (X) 8-51 Page 1 of 2 Rev. 11/15 Pollutant Control 4.504.1 Duct openings and other related air distribution component openings shall be covered (X) during construction. 4.504.2.1 Adhesive, sealants and caulks shall be compliant with VOC and other toxic compound (X) limits. (X) 4.504.2.2 Paints, stains and other coatings shall be compliant with VOC limits. (X) 4.504.2.3 Aerosol paints and coatings shall be compliant with product weighted MIR limits for ROC and other toxic compounds. . (X) 4.504.2.4 Documentation shall be provided to verify that compliant voe limit finish materials have been used. (X) 4.504.3 Carpet and carpet systems shall be compliant with voe limits. 4.504.4 50 percent of floor area receiving resilient flooring shall comply with voe-emission limits (X) defined in the Collaborative for High Performance Schools (CHPS) Low-emitting Materials List or be certified under the Resilient Floor Covering Institute (RFCI) FloorScore program. (X) 4.504.5 Particleboard, medium density fiberboard (MDF) and hardwood plywood used in interior finish svstems shall comply with low formaldehvde emission standards. Interior Moisture Control 4.505.2 Vapor retarder and capillary break is installed at slab on grade foundations. (X) 4.505.3 Moisture content of building materials used in wall and floor framing is checked before (X) enclosure. Indoor Air Quality and Exhaust 4.506.1 Exhaust fans which terminate outside the buildina are provided in everv bathroom. (X) Environmental Comfort 4.507.1 Whole house exhaust fans shall have insulated louvers or covers which close when the (X) fan is off. Covers or louvers shall have a minimum insulation value of R-4.2. 4.507.2 Duct systems are sized, designed, and equipment is selected using the following methods: (X) 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent. 2. Size duct systems according to ACCA 29-D (Manual D) or equivalent 3. Select heatina and coolina eauipment accordina to ACCA 36-S (Manual S) or eauivalent. ,. . Installer and Special Inspector Qualifications 702.1 HVAC system installers are trained and certified in the proper installation of HVAC (X) systems. 702.2 Special inspectors employed by the owner must be qualified and able to demonstrate (X) competence in the discipline thev are inspectina. I, as the professional responsible for this project, certify that, to the best of my knowledge, the mandatory items listed on this form have been incorporated into the project in order to comply with Title 24, Part 11 of the 2013 California Green Building Standards. All receipts for recycled materials have been attached to this form. Project Address: .,7 tou.t Lllac\..S: ~r ~b ~+ . Plan Check Number: j>C.. \~ -~. \ '2.. Print Name: ~""iiS Sm~ S Signed: ~ ~\3 f c2 License Number: Co 'Bis-~; Date: 8-51 Page 2 of 2 Rev.11/15 '< ~ CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 1) Project Name: The Vistas at Robertson Ranch Enforcement Agency: City of Permit Number: CB163170 Carlsbad Dwelling Address: 2648 Wadsworth Street City: Carlsbad Zip Code: 92010 HERS measure was verified using the methodology defined for the untested features included in a sample group. This measure passes through its relationship with the actual one tested and passed. Therefore no data is included on this Certificate of Verification. Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: /---·--~~ Lorena Pichardo Company: Energy Inspectors Date Signed: ')(l'( 7 fl" ,. 7 ~ ~ .t=: .. 0 &::.fl Address: CEA/ HERS Certification Identification (if applicable): 2570 South Miller Lane City/State/Zip: Las Vegas NV 89117 Phone: 702-365-8080 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided Gin this Certificate of Compliance is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificat~ ofVerificaNon (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS vefification identified on this Certificate of Verification comply with the applicable re-quirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (installing Subcontractor, General Contractor, or Builder/Owner): AIREFORCE HEATING & AIR INC Responsible Builder or Installer Name: CSLB License: Michelle Sanchez HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) 217-00817 Not tested HERS Rater Information HERS Rater Company Name: Energy Inspectors Responsible Rater Name: Responsible Rater Signature: ~ ~ -;.£,,_t::?,../ Joseph Schwartz -... ~ Responsible Rater Certification Number w/ this HERS Provider: Date Signed: -, CC2004506 2017-02-17 12:09:28 Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-N01633490-M2000018A-M20A CA Building Energy Efficiency Standards 2013 Residential Compliance Registration Date/Time: 2017-02-17 12:09:28 HERS Provider: CalCERTS Report Version: 2013 Rev 1.008 Report Generated: 2017-02-17 11:47:13 Schema Version: 0.52500 CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 1) Project Name: The Vistas at Robertson Ranch Enforcement Agency: City of Permit Number: CB163170 Carlsbad Dwelling Address: 2648 Wadsworth Street City: Carlsbad Zip Code: 92010 HERS measure was verified using the methodology defined for the untested features included in a sample group. This measure passes through its relationship with the actual one tested and passed. Therefore no data is included on this Certificate of Verification. Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: A~--~-~~ Lorena Pichardo Company: Energy Inspectors Date Signed: """ 7 ,,,., '1 7 '1 '1 .,::,, .,:::r, Address: CEA/ HERS Certification Identification (if appficable): . - 2570 South Miller Lane City/State/Zip: Las Vegas NV 89117 Phone: 702-365-8080 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance Is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificat~ of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CFlR) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): AIREFORCE HEATING & AIR INC Responsible Builder or Installer Name: CSLB License: Michelle Sanchez HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) 217-00817 Not tested HERS Rater Information HERS Rater company Name: Energy Inspectors Responsible Rater Name: Responsible Rater Signature: ;t}_ ~ -~,£.~-/ Joseph Schwartz ---~ Responsible Rater Certification Number w/ this HERS Provider: Date Signed: -, CC2004506 2017-02-17 12:09:28 Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-N0163349D-M2000019A-M20A CA Building Energy Efficiency Standards 2013 Residential Compliance Registration Date/Time: 2017-02-17 12:09:28 HERS Provider: CalCERTS Report Version: 2013 Rev 1.008 Schema Version: 0.52SDD Report Generated: 2017-02-17 11:47:17 CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 1 of 1) Project Name: The Vistas at Robertson Ranch Enforcement Agency: City of Permit Number: CB163170 Carlsbad Dwelling Address: 2648 Wadsworth Street City: Carlsbad Zip Code: 92010 HERS measure was verified using the methodology defined for the untested features included in a sample group. This measure passes through its relationship with the actual one tested and passed. Therefore no data is included on this Certificate of Verification. Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: ~--Lorena Pichardo I -~~ Company: Energy Inspectors Date Signed: 'lf\17 ('\') 17 11,/:1,/:(\ Address: CEA/ HERS Certification Identification (if applicable): 2570 South Miller Lane City/State/Zip: Las Vegas NV 89117 Phone: 702-365-8080 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificat~ of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CFlR) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): AIREFORCE HEATING & AIR INC Responsible Builder or Installer Name: CSLB License: Michelle Sanchez HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) 217-00817 Not tested HERS Rater Information HERS Rater company Name: Energy Inspectors Responsible Rater Name: Responsible Rater Signature: fl_ --,,.£,.~-/ Joseph Schwartz Responsible Rater Certification Number w/ this HERS Provider: Date Signed: ~ , CC2004506 2017-02-17 12:09:28 Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document. and in no way implies Registration Provider responsibility for the accuracy of the information. ........ Registration Number: 215-N0163349D-M2300018A-M23A CA Building Energy Efficiency Standards 2013 Residential Compliance Registration Date/Time: 2017-02-17 12:09:28 HERS Provider: CalCERTS Report Version: 2013 Rev 1.008 Report Generated: 2017-02-17 11:48:16 Schema Version: 0.52SDD CERTIFICATE OF VERIFICATION CF3R-MCH-23-H Space Conditioning System Airflow Rate (Page 1 of 1) Project Name: The Vistas at Robertson Ranch Enforcement Agency: City of Permit Number: CB163170 Carlsbad Dwelling Address: 2648 Wadsworth Street City: Carlsbad Zip Code: 92010 HERS measure was verified using the methodology defined for the untested features included in a sample group. This measure passes through its relationship with the actual one tested and passed. Therefore no data is included on this Certificate of Verification. Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: ~--Lorena Pichardo -~~ Company: Energy Inspectors Date Signed: 'JfH7 n'> ~7 ~~.i::;~.i:::n Address: CEA/ HERS Certification Identification (if appficable): 2570 South Miller Lane City/State/Zip: Las Vegas NV 89117 Phone: 702-365-8080 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the Jaws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verificatiori identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): AIREFORCE HEATING & AIR INC Responsible Builder or Installer Name: CSLB License: Michelle Sanchez HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) 217-00817 Not tested HERS Rater Information HERS Rater Company Name: Energy Inspectors Responsible Rater Name: Responsible Rater Signature: 1'1.; ~ -,,,£,,~ / Joseph Schwartz Responsible Rater Certification Number w/ this HERS Provider: Date Signed: -, CC2004506 2017-02-17 12:09:28 Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information. ~ Registration Number: 215-N0163349D-M2300019A-M23A CA Building Energy Efficiency Standards Registration Date/rime: 2017-02-17 12:09:28 HERS Provider: CalCERTS 2013 Residential Compliance Report Version: 2013 Rev 1.008 Schema Version: 0.52SDD Report Generated: 2017-02-17 11:48:22 CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 1 of 1) Project Name: The Vistas at Robertson Ranch Enforcement Agency: City of Permit Number: CB163170 Carlsbad Dwelling Address: 2648 Wadsworth Street City: Carlsbad Zip Code: 92010 HERS measure was verified using the methodology defined for the untested features included in a sample group. This measure passes through its relationship with the actual one tested and passed. Therefore no data is included on this Certificate of Verification. Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: A--Lorena Pichardo -~~ Company: Energy Inspectors Date Signed: 'Jn17 n'J 17 11.i:::1.i:::n Address: CEA/ HERS Certification Identification (if appficao1e): 2570 South Miller Lane City/State/Zip: Las Vegas NV 89117 Phone: 702-365-8080 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system perfo-~mance diagnosti'c results that 'require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CFlR) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): AIREFORCE HEATING & AIR INC Responsible Builder or Installer Name: CSLB License: Michelle Sanchez HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) 217-00817 Not tested HERS Rater Information HERS Rater Company Name: Energy Inspectors Responsible Rater Name: Responsible Rater Signature: /,) ~ -".£..~/--..,..~ Joseph Schwartz Responsible Rater Certification Number w/ this HERS Provider: Date Signed: -, CC2004506 2017-02-17 12:09:28 Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-N0163349D-M2200018A-M22A CA Building Energy Efficiency Standards 2013 Residential Compliance Registration Date/Time: 2017-02-17 12:09:28 HERS Provider: CalCERTS Report Version: 2013 Rev 1.008 Schema Version: 0.52SDD Report Generated: 2017-02-17 11:47:44 CERTIFICATE OF VERIFICATION CF3R-MCH-22-H Space Conditioning System Fan Efficacy (Page 1 of 1) Project Name: The Vistas at Robertson Ranch Enforcement Agency: City of Permit Number: CB163170 Carlsbad Dwelling Address: 2648 Wadsworth Street City: Carlsbad Zip Code: 92010 HERS measure was verified using the methodology defined for the untested features included in a sample group. This measure passes through its relationship with the actual one tested and passed. Therefore no data is included on this Certificate of Verification. Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: A~-·-Lorena Pichardo ~~ Company: Energy Inspectors Date Signed: """7 nri a"7 •1.ca.cr, Address: CEA/ HERS Certification Identification (if appficable): 2570 South Miller Lane City/State/Zip: Las Vegas NV 89117 Phone: 702-365-8080 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic resultsthat require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (installing Subcontractor, General Contractor, or Builder/Owner): AIRE FORCE HEATING & AIR INC Responsible Builder or Installer Name: CSLB License: Michelle Sanchez HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) 217-00817 Not tested HERS Rater Information HERS Rater Company Name: Energy Inspectors Responsible Rater Name: Responsible Rater Signature: 0... ~ -/.,£,,. e. / Joseph Schwartz Responsible Rater Certification Number w/ this HERS Provider: Date Signed: -~ CC2004506 2017-02-17 12:09:28 Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. _..._ ',,, Registration Number: 215-N0163349D-M2200019A-M22A CA Building Energy Efficiency Standards Registration Date/Time: 2017-02-17 12:09:28 HERS Provider: CalCERTS 2013 Residential Compliance Report Version: 2013 Rev 1.008 Schema Version: 0.52SDD Report Generated: 2017-02-17 11:47:50 CERTIFICATE OF VERIFICATION CF3R-MCH-27-H Indoor Air Quality and Mechanical Ventilation {Page 1 of 1) Project Name: The Vistas at Robertson Ranch Enforcement Agency: City of Permit Number: CB163170 Carlsbad Dwelling Address: 2648 Wadsworth Street City: Carlsbad Zip Code: 92010 HERS measure was verified using the methodology defined for the untested features included in a sample group. This measure passes through its relationship with the actual one tested and passed. Therefore no data is included on this Certificate of Verification. Documentation Author's Declaration Statement 1. I certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: Lorena Pichardo A=.----~~ Company: Energy Inspectors Date Signed: "lfH"1 n"l • ., ••.,:: •. en Address: CEA/ HERS Certification Identification (ifappficable): ·-·- 2570 South Miller Lane City/State/Zip: Las Vegas NV 89117 Phone: 702-365-8080 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the appficable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CFlR) approved by the enforcement agency. 5. I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): AIREFORCE HEATING & AIR INC Responsible Builder or Installer Name: CSLB License: Michelle Sanchez HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (if applicable) 217-00817 Not tested HERS Rater Information HERS Rater Company Name: Energy Inspectors Responsible Rater Name: Responsible Rater Signature: ~ --~.£.-./~~ / Joseph Schwartz Responsible Rater Certification Number w/ this HERS Provider: Date Signed: -, ((2004506 2017-02-17 12:09:28 Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. ........... '.8 Registration Number: 215-N0163349D-M2700017 A-M27 A CA Building Energy Efficiency Standards Registration Date/Time: 2017-02-1712:09:28 HERS Provider: CalCERTS 2013 Residential Compliance Report Version: 2013 Rev 1.008 Schema Version: 0.52SDD Report Generated: 2017-02-17 11:48:41 CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING Additional Energy Features Additional Energy Feature Verification (Page 1 of 1) Project Address: 2648 Wadsworth Street Carlsbad CA, 9201 0 Builder Name: Toll Brothers, Inc. -Southern CA Builder Contact: na Telephone: 999-999-9999 Plan Number: Tolll 47 Plan 4 Standard I Sample Group Number: 217-008171 Sample House Number: 1017930 HERS Rater: Joseph Schwartz Telephone: 702-365-8080 Certifying Signature: ~~~SCMI~ Date: 2017-02-17 12:09:28 Firm: Energy Inspectors HERS Provider: CalCERTS inc. Street Address: 2570 South Miller Lane City/State/Zip: Las Vegas I NV I 89117 HERS measure was verified using the methodology defined for the untested features included in a sample group. This measure passes through its relationship with the actual one tested and passed. Therefore no data is included on this Certificate of Verification. 1 a) Radiant Barrier Required: 1 b) Was the Radiant Barrier installed? 2) Opaque Surfaces: 3) Glazing (Window) Values: 4) HVAC Efficiency: 5) Verify Water Heater Efficiency: N/A N/A N/A N/A N/A N/A