Loading...
HomeMy WebLinkAbout2649 OCEAN ST; ; CB121719; Permit- City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 10-29-2012 Residential Permit Permit No: CB121719 Building Inspection Request Line (760) 602-2725 Job Address: 2649 OCEAN ST CBAD Permit Type: RESDNTL Sub Type: RAD Status: ISSUED Parcel No: 2031401000 Lot #: 0 Applied: 09/04/2012 Valuation: $123,697.00 Constuction Type: 5B Entered By: RMA Occupancy Group: Reference #: Plan Approved: 10/29/2012 # Dwelling Units: 0 Structure Type: Issued: 10/29/2012 Bedrooms: 0 Bathrooms: 0 Inspect Area: Orig PC #: Plan Check #: Project Title: HUBER RES- REMODEL EXIST 1980 . SF IN LEVEL ONE (DEMO & RE-DO 2 BATH, NEW BAR & NEW MUSIC STUDIO), ADD NEW 172 SF LOFT . Applicant: Owner: . . MICHAEL ROLLINS HUBER FAMILY TRUST 12-03-07 STE 397 5663 BALBOA AV 2649 OCEAN ST SAN DIEGO CA 92111 CARLSBAD CA 92008 619 993-6003 Building Permit $789.70 Meter Size Add'I Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00 Plan Check $552.79 Meter Fee $0.00 Add'I Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee . $12.37 PFF (3105540) $0.00 Park in Lieu Fee $0.00 PFF (4305540) . $0.00 Park Fee $0.00 License Tax (3104193) $0.00 LFM Fee $0.00 License Tax (4304193) $0.00 Bridge Fee $0.00 Traffic Impact Fee (3105541) $0.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541) $0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL $80.00 Renewal Fee $0.00 ELECTRICAL TOTAL $41.00 Add'I Renewal Fee $0.00 MECHANICAL TOTAL $0.00 Other Building Fee $0.00 Housing Impact Fee $0.00 HMP Fee . . $0.00 Housing InLieu Fee $0.00 Pot. Water Con. Fee $0.00 Housing Credit Fee $0.00 Meter Size Master Drainage Fee $0.00 Add'I Pot. Water Con. Fee $0.00 Sewer Fee $0.00 Red. Water Con. Fee . $0.00 Additional Fees .. . $0.00 Green Bldg Stands (SB 1473) Fee . $4.00 Fire Sprinkler Fees. . . $0.00 Green Bldg Stands Plan Chk Fee $0.00 TOTAL PERMIT FEES $1,479.86 Total Fees: $1,479.86 Total Payments to Date: $1,479.86 Balance Due: $0.00 FINAL APPROVAL Inspector: -.it Date: /0 '"V' Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. I -.•. _ - . IThE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE" PLANNING 0 ENGINEERING 8UILDING 0 FIRE 0 HEALTH, 0 HAZMAT/APCD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 C I T Y -OF Ph: 760-602-2719 Fax: 760-602-8558. email: buIdIIni@carIsbadca.gov . CARLSBAD www.carlsbadcá.ov Plan Check No. rlp/ Est. Value Plan Ck. Deposit .rZ 7 £/ swPP. . JOB ADDRESS APN SUITE#/SPACE#/UNIT# i CT/PROJECT # LOT # 13 +14,I I PHASE # . I # OF UNITS I .i. # BEDROOMS ••.I. I # BATHROOMS I TENANT BUSINESS NAME . I . . I CONSTR. TYPE I I 0CC GROUP I DESCRIPTION OF WORK: include Square Feet of Affected Area(s) F , CT 4tf7u/i ( •c64vk,Uc/o. LL Vi EXISTING USE -•.= PROPOSED USE I. I GARAGE (SF) PATIOS (SF) DECKS (SF) I FIR PLACE . YES D #_ NOD JAIRCONDITICININ00 YES 0 NOD FIRE YES 0 NOD APPLICANT NAME (Primary Contact) M j . APPLICANT NAME (Secondary Contact) ADDRESS l3J- 4. 034q7,ADDRESS CITY —w STATE/f ZIPq/.f( CITY • STATE -. ZIP PHONE 641 5 .1 IFc . . . . PHONE . FAX I EMAIL pfl,\kej EMAIL PROPERTY OWNER NAME /fCAb CONTRACTOR BUS. NAME I /cJ ADDRESS o . ADDRESS qc icMey €?i- CITY I Is J ST AT ZIP 4 CITY STAT q zIPc2O75 le PHONE g533Lfj33 FAX . Pr 59 FAX EMAIL . . . EMAIL ARCH/DESIGNER NAME & ADDRESS I STATE UC.# sTATEUC.#33/g IC556 I. CITY BUS. LIC.# (Sec. 7O1.5 business ano ProTessions code: Any CItY or County whIch requires a permit applicant for such permit to file a signed statement that he is licensed pursuantto the pr Business and Professions Code) or that he is exempt therefrom, and the basis for the all civil penalty of not more than five hundred dollars ($500)). I i.a iw faI - Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: D).1('ave and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. LM I have and will maintain workers compensation, as uired by Section 3700 of the Labor Code, for the performance of the permh is issued. My workers' compensatio in ura 5amer and policy number are: Insurance Co. JO)fLT l' Policy No. 2 i"i / Expiration Data number 7. )• This section need not be completed if the permit is for one hundred dollars ($100) or less. . O Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation cover e is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in .addition to the cost of compensation, dama s pro r in Se o f the Labor code, interest and attorney's fees. • CONTRACTOR SIGNATURE - ; • DATE t.'I•1IrU!I:lIIIUUrl, .. _____________ - I hereby affirm that! am exempt from Contractor Ucense Law for the following reason: - 0 I, as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not Intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). - 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the-Contractor's License Law). . . 0 lam exempt under Section • Business and Professions Code for this reason: - - I personally plan to provide the major labor and materials for construction of the proposed property improvement. CI Yes. CI No . I (have! have not) signed an application for a building permit for the proposed work. - I have contracted with the following person (firm) to provide the proposed construction (include name address! phone !contractors' license number): - I plan to provide portions of the work, butt have hired the following person to coordinate, supervise and provide the major work (include name! address! phone !contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name! address! phone/type of work): .'PROPERTY OWNER SIGNATURE • • - OAGENT • DATE. to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the ovisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the rged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a I. &®'(317t WOO 09OU000 I®(D ® O®@J'O1 .OQd)O()@ O173 ®(? Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 Yes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYes 0 No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYes 0 No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTiFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. ®(G? - I hereby affirm that there is a nstruction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address OtJ? OtOO®L1 I certifythati have read #is application and state thatthe above Infibrmation is conectand thatthe Information on the plans is accurate. I agreeto compkvAth all City ordinances and Stateless ,elatingtobuildlngccnstiucdon.. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA- An OSHA permit is required for excavations over 60 deep and demolition or construction of structures over 3stories in height EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void tithe building or work authorized by such permits not commenced within 180 days from the date of such permit orif the building or walk auth ed by such pe is suspended ora ned at any tirne after the vorkis commenced braperbd of 180days ( n 106.4.4 Uniform Building Code). 'APPUCANT'S SIGNATURE DATE VA ' STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CERTIFICATE OF • OCC U PANCY i . Fax (760) 602-8560, Email www.buiIdina(.cadsbadca.qov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. CO#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS 0 PICKUP. D CONTACT (Listed above) D OCCUPANT (Listed above) c CONTRACTOR (On Pg. 1) ASSOCIATED CS# O MAIL TO: a CONTACT (Listed above) 0 OCCUPANT (Listed above) a CONTRACTOR (On Pg. 1) a NO CHANGE IN USE / NO CONSTRUCTION 0 MAIL/ FAX TO OTHER: CHANGE OF USE! NO CONSTRUCTION ..APPLICANT'S SIGNATURE DATE Inspection List Permit#: CB121719 Type: RESDNTL RAD HUBER RES- REMODEL EXIST 1980 SF IN LEVEL ONE (DEMO & RE-DO 2 BAT Date Inspection Item InspectorAct Comments 10/07/2014 19 Final Structural - RI HUBER RES 10/07/2014 19 Final Structural PB AP 07/16/2014 18 Exterior Lath/Drywall PD AP 05/16/2014 17 Interior Lath/Drywall PB AP 04/22/2014 84 Rough Combo PD AP 04/01/2014 84 Rough Combo PD' AP 03/24/2014 84 Rough Combo PD PA 03/14/2014 84 Rough Combo PD PA 01/07/2014 14 Frame/Steel/Bolting/Weldin PB PA Wednesday, October 08, 2014 Page 1 of 1 EsGil Corporation In (Partners/lip with government for (Building Safety DATE: 10/09/12 UA lENT U JURIS. JURISDICTION: Carlsbad U PLAN REVIEWER U FILE PLAN CHECK NO.: 12-1719 SET: II PROJECT ADDRESS: 2649 Ocean Street PROJECT NAME: Remodel/ Mezzanine for Huber Residence El The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. El The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. El The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. El The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. El The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. El EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Mail Telephone Fax In Person REMARKS: Complete special inspection form for items listed on S2.0 By: Ray Fuller Enclosures: EsGil Corporation 0 GA 0 EJ 0 PC (P) 10/04/12 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In Partners flip witfi government for Bui(iing Safety DATE: 09/10/12 JURISDICTION: Carlsbad PLAN CHECK NO.: 12-1719 SET: I PROJECT ADDRESS: 2649 Ocean Street PROJECT NAME: Remodel/ Mezzanine for Huber Residence AP NT U JURIS. U PLAN REVIEWER U FILE E The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans, transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. E The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Michael Rollins 5663 Balboa Ave. #397 San Diego, Ca. 92111 EsGil Corporation, staff did not advise the applicant that the plan ôheck has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Mjchael Rollins (,,,&4)Telephone #: (619) 993-6003 Date contacted: I (by: ,L.) Email: michaekrollinscc.com tMaiI - Telephone—' Fax In Person LI REMARKS: By: Ray Fuller Enclosures: EsGil Corporation D GA 0 EJ 0 Pc 09/04/12 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 12-1719 09/10/12 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 12-1719 JURISDICTION: Carlsbad PROJECT ADDRESS: 2649 Ocean Street FLOOR AREA: Remodel 1980 Mezzanine 172 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 09/04/12 DATE INITIAL PLAN REVIEW COMPLETED: 09/10/12 STORIES: Existing HEIGHT: Existing DATE PLANS RECEIVED BY ESGIL CORPORATION: 09/04/12 PLAN REVIEWER: Ray Fuller FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2010 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2009 IRC, 2009 IBC, 2009 UPC, 2009 UMC and 2008 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad 12-1719 09/10/12 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for residential projects. For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building, Department, 1635 Faraday Ave., Carlsbad, CA 92009, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 2. Verify that the final sets of plans and any new calculations will be stamped and signed by engineer and /or architect of record also. 3. Cover sheet is noting total sq footage at basement to be 2072 sq ft and per permit application the existing basement is 1980 and adding a loft /mezzanine of 172 sq ft. The sq footages don't add up. Please clarify, 4. Plans to clearly note that basement was conditioned space and if not then would need to provided energy calculations for proposed work. 5. A minimum of two cross sections will be required as in no way could determine the scope of work with out this. Could not complete plan check as scope of work is unclear. Some examples of unanswered questions are below. 6. Without cross sections cannot verify ceiling heights above and below the loft! mezzanine. 7. Could not determine how exercise room is provided with required light and ventilation? 8. Recheck outlet spacing. Must show outlets within 6 ft of any opening and not to exceed 12 apart. Any isolated wall 2 ft or wider to have outlets. See exercise room for example. 9. Include a receptacle outlet in any hallways 10 feet or more in length. CEC Article 210.52(H). Carlsbad 12-1719 09/10/12 10. Show or note that a battery-operated carbon monoxide alarms will be provided outside each separate sleeping area in the immediate vicinity of the bedrooms and on each story. Section R315.2. 11. Include on the plans the following specifications for any new electrical devices installed: Tamper resistant receptacles required for all locations. Weather resistant type for receptacles installed in damp or wet locations (outside). Arc-fault protection for all outlets (not just receptacles) located in rooms described in NEC 210.12(B): Family, living, bedrooms, dining, halls, etc. 12. Could not locate the lighting in the Music studio and verify complies with energy requirements i.e. high efficacy or be controlled by a vacancy sensor or dimmer. Please define what SM means as show at bathrooms. 13. Does water heater exist as shown on A1.01 and if so note this. 14. Specify on the plans: Water conserving fixtures: New water closets shall use no more than 1.28 gallons of water per flush, lavatories may not exceed 2.2 GPM, and showers may not exceed 2.5 GPM of flow. CPC Section 402.0. 15. Plans are reflecting removing two steps so I guess that the music studio will be on a elevated platform. No architectural or structural details provided for new step (maximum rise of 7 %" ) and for framing or concrete platform. 16. Please add field welding to special inspection list on S2.0 and complete attached form before pulling permit. 17. Please verify curved C channels are designed for torsional analysis. 18. No detail for how the curved CIO x53 is to be attached to existing concrete wall and /or how attached to the 4x 4 post (verify details reflect how this connection will resist torsional forces from the curved CIO x53. 19. No details provided for what appears to be large glass area for music studio. Show the thickness of the butted glass, whether or not tempered and to be supported on all four sides. Verify details provided in the calculations are reflected on the plans. 20. Could not determine on the plans how wall below the glass is to resist out- of- plane loading as glass is not perpendicular to wall below. Have no idea how large the glass panes are and concerned about the safety of the occupants due to breakage from earthquake or impact force. 21. The isolation dampers and sway braces are apart of this permit and need to be detailed and referenced. Carlsbad 12-1719 09/10/12 Please verify details reflect the correct orientation of the metal pan (71S2.0 ) and complete mezzanine framing plan to include details of connection of pan to concrete wall and span of the pan. Provide manufacturer's name and spec's for metal pan to show adequate for distances must span. Provide structural section through the lower level. There are no floor level elevations provided and I can not determine the relationship of the various floor levels as shown on the architectural plans. It appears-that you intend to provide an elevated studio floor that is on a different level from the exercise area and in addition the architectural plans include a" storage! mechanical " level. It is not clear how all these level ft within the existing single floor level. Clarify how you intend to support the ends of the HSS6X4XI/4 beams above the glass wall at the pointed end (Butt glass ) where there is no vertical support for these HSS beams? To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes() No () The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858!560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Ray Fuller at Esgil Corporation. Thank you. Carlsbad 12-1719 09/10/12 CITY OF CARLSBAD SPECIAL INSPECTION AGREEMENT B-45 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov In accordance with Chapter 17 of the California Building Code the following must be completed When Work being performed requires special inspection, structural observation and construction material testing. 'roject/Permit: Project Address: THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder 0. (If you checked as owner-builder you must also complete Section B of this agreement.) Name: (Please print) First) (M.I.l (LaS) Mailing Address: Email_______________________________________________________ Phone:________________________ I am: OProperty Owner oProperty Owner's Agent of Record 0Architect of Record 0Engineer of Record State of California Registration Number Expiration Date AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspections noted on the approved plans and, as required by the California Building Code. Signature: Date: CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor / builder! owner-builder. Contractor's Company Name: Please check If you are Owner-Builder 0 Name: (Please print) (First) (MI.( (Lost) Mailing Address: Email:_________________________________________________________ Phone:___________________________ State of California Contractor's License Number: Expiration Date: I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. I will arovide a final report / letter in compliance with CBC Section 1704.1.2 prior to requesting final Signature: Date: B-45 Page 1 of 1 Rev. 08/11 Carlsbad 12-1719 09/10/12 [DO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 12-1719 PREPARED BY: Ray Fuller DATE: 09/10/12 BUILDING ADDRESS: 2649 Ocean Street BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION: VB BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Remodel 1980 7.'(S' 104,940 Loft 172 -5 O 9,116 Air Conditioning Fire Sprinklers TOTAL VALUE 114,056 Jurisdiction Code 1cb IBY Ordinance Bldg. Permit Fee by Ordinance I $754,421 Plan Check Fee by Ordinance I I $490.371 Type of Review: Complete Review D Structural Only Repetitive Fee El Other D Hourly Repeats IHr. EsGil Fee I 1 1 $422.48! D Comments: Sheet I of I macvalue.doc + 4 /A\, 7,4> CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.Rov DATE: September 5, 2012 PROJECT NAME: PROJECT ID: PLAN CHECK NO: CB 12-1719 SET#: I ADDRESS: 2649 Ocean St APN: 203-140-10-00 This plan check review is complete and has been APPROVED by the Planning Division. By: Chris Sexton A Final Inspection by the Planning Division is required Yes Z No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 Chris Sexton Kathleen Lawrence LI Greg Ryan 760-602-4624 760-602-2741 760-602-4663 Chris.Sexton@carlsbadca.gov KathIeen.Lawrence@carIsbadca.gov Gregorv.Rvan@carlsbadca.gov Gina Ruiz. 'Linda Ontiveros LII Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.Eov Cynthia.Wonp@carlsbadca.gov F] F-1 Dominic Fieri L.J 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: PERMIT NUMBER CB 12-1719 DATE September 5 2012 ADDRESS 2649 Ocean Street RESIDENTIAL ADDITION- POOL/SPA MINOR (071000.00) TENANT IMPROVEMENT RETAINING WALL COMPLETE OFFICE BUILDING VILLAGE FAIRE SOLAR PANELS OTHER interior remodel PLANNER Chris Sexton DATE September 5, 2012 P-29 Page 2 of 2 07/11