HomeMy WebLinkAbout2649 WADSWORTH ST; ; CB163162; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
08-26-2016 Residential Permit Permit No: CB163162
Building Inspection Request Line (760) 602-2725
Job Address:2649 WADSWORTH ST CBAD
Permit Type:RESDNTL Sub Type: SFD Status: ISSUED
Parcel No:2081930300 Lot #:217 Applied: 08/17/2016
Valuation:$603,281.00 Constuction Type: 5B Entered By: SLE
Occupancy Group:Reference #: CT130003 Plan Approved: 08/26/2016
# Dwelling Units:1 Structure Type: SFD Issued: 08/26/2016
Bedrooms:5 Bathrooms:5.5 Inspect Area: PB
Orig PC #: PC150042 Plan Check #: PC160048
Project Title:THE VISTAS: PHASE 4 / PLAN 4
3,897 SF LIV / 432 SF GARAGE / 229 SF PORCH
Applicant:Owner:
TOLL BROTHERS INC RANCHO COSTERA LLC
200 200
725 W TOWN AND COUNTRY RD 725 W TOWN AND COUNTRY
ORANGE CA 92868 ORANGE CA 92868
760-720-5485 760-720-5485
Building Permit $2,349.26 Meter Size FS3/4
Add'I Building Permit Fee $0.00 Add'I Red. Water Con. Fee $0.00
Plan Check $1,644.48 Meter Fee $356.00
Add'I Plan Check Fee ($500.00)SDCWA Fee $4,963.00
Plan Check Discount ($131.56)CFD Payoff Fee $1,723.10
Strong Motion Fee $78.43 PFF (3105540)$10,979.71
Park in Lieu Fee $0.00 PFF (4305540)$0.00
Park Fee $0.00 License Tax (3104193)$0.00
LFM Fee $0.00 License Tax (4304193)$0.00
Bridge Fee $0.00 Traffic Impact Fee (3105541)$2,690.00
Other Bridge Fee $0.00 Traffic Impact Fee (4305541)$0.00
BTD #2 Fee $0.00 Sidewalk Fee $0.00
BTD #3 Fee $0.00 PLUMBING TOTAL $339.00
Renewal Fee $0.00 ELECTRICAL TOTAL $89.00
Add' Renewal Fee $0.00 MECHANICAL TOTAL $137.08
Other Building Fee $0.00 Housing Impact Fee $0.00
HMP Fee $0.00 Housing InLieu Fee $0.00
Pot. Water Con. Fee $5,609.00 Housing Credit Fee $0.00
Meter Size FS3/4 Master Drainage Fee $0.00
Add'I Pot. Water Con. Fee $0.00 Sewer Fee $2,103.00
Red. Water Con. Fee $0.00 Additional Fees $0.00
Green Bldg Stands (SB1473) Fee $25.00 Fire Sprinkler Fees $0.00
Green Bldg Stands Plan Chk Fee $0.00
TOTAL PERMIT FEES $32,454.50
Total Fees:$32,454.50 Total Payments to Date:$32,454.50 Balance Due:$0.00
FINAL APPROVAL
Inspector:hit Date:2-•"7 24)11 Clearance:
NOTICE:Please take CE that approval of your project includes the "Irrposition"cffees, dedcaticns, reservations, or other exactions hereafter allectively
referred to as leedexacticns."You have 90 days from the date this perrrit was issued to protest impositiondthese fees/exactions.If you protest them you must
fi
follow the protest prooeckres set forth in Ga./lament Code Section 66023(a), and file the protest aid any other required information with the City Attartager for
processing in accordance with Carlsbad Nitnidpal Code Section 3.32.030.Failtre to timely follow that procedure will ben any subsequent legal action to attack,
review, set aside, void,a annul their imposition.
You are hereby FLRT1-ER NOTIFIED that your right to protest the spedfied fees/exactiais DOES NOT APPLY to wateraid sewer connection fees and capacity
changas, nor planring, zoning, gracing a other similar application processing a service fees in connection with this project.NCR DOES IT APPLY to any
fees/exactions of Mich you have crevia.sly been riven a NOTICE similar to this. or as to which the statute cf limitations has previously otherwise emoirsd.
-.
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Storm Water Pollution Prevention Plan (SWPPP) Permit
08-26-2016 Permit No:SW160374
Job Address:2649 WADSWORTH ST CBAD
Permit Type:SWPPP Status:ISSUED
Parcel No:2081930300 Lot #:217 Applied:08/18/2016
Reference #:Entered By:SLE
CB#:CB163162 Issued:08/26/2016
Inspect Area:
Project Title:THE VISTAS: PHASE 4 / PLAN 4 Tier:1
Priority:L
Applicant:Owner:
TOLL BROTHERS INC RANCHO COSTERA LLC
200 200
725 W TOWN AND COUNTRY RD 725 W TOWN AND COUNTRY
ORANGE CA 92868 ORANGE CA 92868
760-720-5485 760-720-5485
Emergency Contact:
GREG DEACON
760-637-9083
SWPPP Plan Check $0.00
SWPPP Inspections $59.00
Additional Fees $0.00
TOTAL PERMIT FEES $59.00
Total Fees:$59.00 Total Payments To Date:$59.00 Balance Due:$0.00
3.FINAL APPROVAL
7.1-11DATE2.CLEARANCE
SIGNATURE IAit #4
Inspection List
Permit#:CB163162 Type:RESDNTL SFD THE VISTAS: PHASE 4 / PLAN 4
3,897 SF LIV / 432 SF GARAGE / 229 SF P
Date Inspection Item Inspector Act Comments
10/31/2016 15 Roof/Reroof AEK AP
09/12/2016 11 Ftg/Foundation/Piers AEK AP
09/06/2016 21 Underground/Under Floor AEK AP
09/06/2016 22 Sewer/Water Service AEK AP
Thursday, February 23, 2017 Page 1 of 1
_..
PERMIT INSPECTION HISTORY REPORT (CB163162)
Permit Type:BLDG-Residential Application Date:08/17/2016 Owner:RANCHO COSTERA LLC
INACTIVE
Work Class:Single Family Detached Issue Date:08/26/2016 Subdivision:
Status:Closed -Finaled Expiration Date:05/01/2017 Address:2649 Wadsworth St
Carlsbad, CA
IVR Number:716497
Scheduled Actual •
Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete
11/16/2016 11/16/2016 BLDG-13 Shear 001395-2016 Passed Andy Krogh Complete
Panels/HD (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
11/29/2016 11/29/2016 BLDG-84 Rough 002969-2016 Passed Andy Krogh Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
12/05/2016 12/05/2016 BLDG-82 Drywall,004190-2016 Passed Andy Krogh Complete
Exterior Lath, Gas
Test, Hot Mop
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-17 Interior Lath-Drywall Yes
BLDG-18 Exterior Lath and Yes
Drywall
BLDG-23 Gas-Test-Repairs Yes
01/24/2017 01/24/2017 BLDG-Electric Meter 010998-2017 Passed Jonathan West Complete
Release
02/22/2017 02/22/2017 BLDG-Final 014386-2017 Passed Jonathan West Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
February 22, 2017 Page 1 of 1
C8163162 2649 WADSWORTH STx.*THE VISTAS: PHASE 4 / PLAN 4\V CITY OF 3,897 SF LI V /432 SF GARAGE /229 SF PORCHCARLSBADINSPECTION RECORD RESDNTL SFD
13,uilding Division Lot#:217 TOLL BROTHERS INC
J INSPECTION RECORD CARD WITH APPROVED
PLANS MUST BE KEPT N THE JOB .4L'N.
<0 CALL BEFORE 3:30 PmFORiNEXT WORK DAY INSPECTION L ..„...j RD COPY.FOR BUILDING INSPECTION CALL:760-602-2725
OR GO TO: www.Cartsbadca.gov/Buildinq AND CLICK ON
"Request Inspection"—„,.............„.._
DATE:Sr .2.4 .a
if "YES" is checked below that Division's approval is required prior to requesting,a Final Building Inspection. If you have any questions
please call the applicable divisions at the phone numbers provided below. After all required approvals are signed off-fax to
760 -602-8560, email to b(dginspections@carlsbadca.gov or bring in a COPY of this card to: 1635 Faraday Ave., Carlsbad.
roi hi .1).'c.ioil .ir/I..4)1 i0 .i)'l!s II)Ill hi 3.)i ;17.'.‘ill (.10 'In ')(0t);..:.,.i:;.;o /:;I)iill .;:iTh .iii Hi 1 II p/oi +/mil.iii..9‘f;iii)1).
NO tal Required Prior to Requesting Building Final If Checked YES Date Inspector Notes
IIIIIPlanning/Landscape 760-944-8463 Allow 48 hours 2-."24-%-i fit.
1111111111 CMS.' (Engineering Inspections)760-438-3891 Call before 2 pm refill /Pc.IIIFire Prevention 760-602-4660 Allow 48 hours P(EINIV •)C\iPA
IIII 11.11III111111111
Type of Inspection Type of Inspection
cone 4 BUILDING Date Inspector cope it ELECTRICAL Date Inspector
#11 FOUNDATION .....-4 #31 0 ELECTRIC UNDERGROUND 0 LIFER
#12 REINFORCED STEEL !Ii/-'fr—"---
#34 ROUGH ELECTRIC
#66 MASONRY PRE GROUT #33 -4 ELECTRIC SERVICE 0 TEMPORARY h-7 Aga T wcs-I
5 0 GROUT 0 WALL DRAINS #35 PHOTO VOLTAIC
#10 TILT PANELS #39 FINAL
#11 POUR STRIPS cone a MECHANICAL
#11 COLUMN FOOTINGS #41 UNDERGROUND DUCTS &PIPING
#14 SUBFRAME
*0 FLOOR 0 CEILING #44 0 DUCT &PLENUM 0 REF. PIPING
#15 ROOF SHEATHING 0-31-1 •.
._#43 HEAT-AIR COND. SYSTEMS
#13 EXT.SHEAR PANELS .,-.:1117011111111C1
#16 INSULATION Cone #COMBO INSPECTION
#18 EXTERIOR LATH #81 UNDERGROUND (11,12,21,31)
#17 INTERIOR LATH &DRYWALL #82 DRYWALL,EXT LATH, GAS TES (17,18,23)g-:5----.lie
#51 POOL EXCA/STEEL/BOND/FENCE #83 ROOF SHEATING, EXT SHEAR (13,15)
#55 PREPLASTER/FINAL #84 FRAME ROUGH COMBO (14,24,34,44)-:---/4 k
#19 FINAL #85 T-Bar(14,24,34,44)
cope tr PLUMBING Date Inspector #89 FINAL OCCUPANCY (19,29,39,49)
#22 0 SEWER & BL/C0 0 PL/CO fp k ...-:FIRE Date Ins •ector
#21 UNDERGROUND OWASTE 0 WTR 12 -'imigv.
#24 TOP OUT 0 WASTE 0 WTR A/S UNDERGROUND VISUAL ,
#27 TUB &SHOWER PAN A/SUNDERGROUND HYDRO
4123 Cl GAS TEST 0 GAS PIPING A/S UNDERGROUND FLUSH
#25 WATER HEATER A/SOVERHEAD VISUAL
IT' /4
rovirfrvi
#28 SOLAR WATER ,A/SOVERHEAD HYDROSTATIC
•te Zar4WIN#29 FINAL A/SFINAL \VA.''\1).140i_
conga STORM WATER F/A ROUGH-IN
#600 PRE-CONSTRUCTION MEETING F/A FINAL
#603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN
i 1'605 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST
#607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM FINAL
#609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST
#610 VERBAL WARNING MEDICAL GAS FINAL.,
REV 10/2012 SEE BACK FOR SPECIAL NOTES
Lor01-4/7
RESIDENTIAL GREEN
BUILDING CODE Development Services(City of STANDARDS MANDATORY Building Division
Carlsbad MEASURES 1635 Faraday Avenue
CERTIFICATION 760-602-2719
CHECKLIST www.carlsbadca.gov
B-51•
This form, signed and completed. and all receipts for the recycled materials shall be
submitted to the Building Inspector prior to Final inspection.
Site Development Mandatory
4.106.2 A plan is developed and implemented to manage storm water drainage during construction.(X)
4.106.3 The site shall be planned and developed to keep surface water away from buildings.(X)
Construction plans shall indicate how site grading or a drainage system will manage all surface water
flows.
Energy Efficiency
4.201.1 Low-rise residential buildings shall meet or exceed the minimum standard design required by (X)
the California Energy Standards.
Water Efficiency and Conservation
Indoor Water Use
4.303.1 Indoor water use shall be reduced by at least 20 percent using one of the following methods:(X)
1.Water saving fixtures or flow restrictors shall be used.7/01/2011
2.A 20 percent reduction in baseline water use shall be demonstrated.
4.303.2 When using the calculation method specified in Section 4.303.1, multiple showerheads shall not (X)
exceed maximum flow rates.7/01/2011
4.303.3 Plumbing fixtures (water closets and urinals) and fittings (faucets and shower heads) shall (X)
comply with specified performance requirements.7/01/2011
Outdoor Water Use
4.304.1 Automatic irrigation systems controllers installed at the time of final inspection shall be weather-(X)
based.
Enhanced Durability and Reduced Maintenance
4.406.1 Joints and openings. Annular spaces around pipes, electric cables, conduits or other openings
in plates at exterior walls shall be protected against the passage of rodents by closing such openings (X)
with cement mortar, concrete masonry or similar method acceptable to the enforcing agency.
Construction Waste Management Plan
4.408.1 A minimum of 50 percent of the construction waste generated at the site is diverted to recycle or (X)
salvage. Recycled material receipts from approved recyclers must be attached to this form.
4.408.2 Where a local jurisdiction does not. have a construction and demolition waste management (X)
ordinance, construction waste management plan, per form B-59, shall be submitted for approval to the
enforcing agency.
Building Maintenance and Operation
4.410.1 An operation and maintenance manual shall be provided to the building occupant or owner.(X)
Environmental Quality
Fireplaces
4.503.1 Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed
woodstove or pellet stove shall comply with US EPA Phase II emission limits where applicable.(X)
Woodstoves, pellet stoves and fireplaces shall also comply with applicable local ordinances.
Apo.
Pollutant Control
4.504.1 Duct openings and other related air distribution component openings shall be covered (X)
during construction.
4.504.2.1 Adhesive, sealants and caulks shall be compliant with VOC and other toxic compound (X)
limits.(X)
4.504.2.2 Paints, stains and other coatings shall be compliant with VOC limits.(X)
4.504.2.3 Aerosol paints and coatings shall be compliant with product weighted MIR limits for
ROC and other toxic compounds.(X)
4.504.2.4 Documentation shall be provided to verify that compliant VOC limit finish materials
have been used.(X)
4.504.3 Carpet and carpet systems shall be compliant with VOC limits.
4.504.4 50 percent of floor area receiving resilient flooring shall comply with VOC-emission limits (X)
defined in the Collaborative for High Performance Schools (CHPS) Low-emitting Materials List or
be certified under the Resilient Floor Covering Institute (RFC!) FloorScore program.(X)
4.504.5 Particleboard, medium density fiberboard (MDF) and hardwood plywood used in interior
finish systems shall comply with low formaldehyde emission standards.
Interior Moisture Control -.
4.505.2 Vapor retarder and capillary break is installed at slab on grade foundations.(X)
4.505.3 Moisture content of building materials used in wall and floor framing is checked before (X)
enclosure.
Indoor Air Quality and Exhaust
4.506.1 Exhaust fans which terminate outside the building are provided in every bathroom.(x)
Environmental Comfort
4.507.1 Whole house exhaust fans shall have insulated louvers or covers which close when the (X)
fan is off. Covers or louvers shall have a minimum insulation value of R-4.2.
4.507.2 Duct systems are sized, designed, and equipment is selected using the following
methods:(X)
1.Establish heat loss and heat gain values according to ACCA Manual J or equivalent.
2.Size duct systems according to ACCA 29-D (Manual D) or equivalent
•3.Select heating and cooling equipment according to ACCA 36-S (Manual S) or equivalent.
Installer and Special Inspoictor Qualifications
702.1 HVAC system installers are trained and certified in the proper installation of HVAC (X)
systems.
702.2 Special inspectors employed by the owner must be qualified and able to demonstrate (X)
competence in the discipline they are inspecting.
I,as the professional responsible for this project, certify that, to the best of my knowledge, the mandatory items
listed on this form have been incorporated into the project in order to comply with Title 24, Part 11 of the 2013
California Green Building Standards. All receipts for recycled materials have been attached to this form.
Project Address:aco.Lic,Locit150(5r .1.In 54:Plan Check Number:PC-1L ee•
Print Name:1v11A.S ANVJS Signed:Ilirbit.tip 14
N1/4.
License Number:Co 8 3511 Date:XA3 cc?
B-51 Page 2 of 2 Rev. 11/15
7
CERTIFICATE OF VERIFICATION CF3R-MCH-20-H
Duct Leakage Diagnostic Test (Page 1 of 1)
Project Name:The Vistas at Robertson Ranch Enforcement Agency:City of Permit Number:CB163162
Carlsbad
Dwelling Address:2649 Wadsworth Street City:Carlsbad Zip Code:92010
HERS measure was verified using the methodology defined for the untested features included in a sample group.
This measure passes through its relationship with the actual one tested and passed. Therefore no data is included
on this Certificate of Verification.
Documentation Author's Declaration Statement
1.I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Lorena Pichardo ,i4vree.f/Pec741.44
Company:Energy Inspectors Date Signed:2017 02 21 12:29:13Address:CEA/ HERS Certification Identification (it applicable):
2570 South Miller Lane
City/State/Zip: Las Vegas NV 89117 Phone:702-365-8080
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of theState of California:
1.The information provided on this Certificate of Compliance is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater).
3.The installed features, materials, components, manBfactured devices, or system performancediagnostic results that require HERS verification
identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements
specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the
construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)approved by the enforcement agency.
5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the
building, and made available to the enforcement agency for all applicable inspections.I understand that a registered copy of this Certificate of
Verification is required to be included with the documentation the builder provides to the building owner at occupancy.
Builder Or Installer Information As Shown On The Certificate Of Installation
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): AIREFORCE HEATING & AIR INC
Responsible Builder or Installer Name:CSLB License:
Michelle Sanchez
HERS Provider Data Registry Information
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
217-00815 Not tested
HERS Rater Information
HERS Rater Company Name:Energy Inspectors
Responsible Rater Name:Responsible Rater Signature:
Daniel Granback g)a/nieeNtamiack
Responsible Rater Certification Number w/ this HERS Provider:Date Signed:
CC2004061 2017-02-21 12:43:12
Digitally signed by CaICERTS.This digital signature is provided in order to secure the content ofthis registered document, and in no way implies
Registration Provider responsibility for the accuracyofthe information.
Registration Number: 215-N01633490-M2000014A-M20A Registration Date/Time:2017-02-21 12:43:12 HERS Provider:CalCERTS
•CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2017-02-21 11:45:51
2013 Residential Compliance Schema Version: 0.52SDD
CERTIFICATE OF VERIFICATION CF3R-MCH-20-H
Duct Leakage Diagnostic Test (Page 1 of 1)
Project Name:The Vistas at Robertson Ranch Enforcement Agency:City of Permit Number:CB163162
Carlsbad
Dwelling Address:2649 Wadsworth Street City:Carlsbad Zip Code:92010
HERS measure was verified using the methodology defined for the untested features included in a sample group.
This measure passes through its relationship with the actual one tested and passed. Therefore no data is included
on this Certificate of Verification.
Documentation Author's Declaration Statement
1.I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Lorena Pichardo ,..eoireita/Pec7/44.:4
Company:Energy Inspectors Date Signed:2017 02 71 12:29:13Address:CEA/ HERS Certification Identification (it appiicanie):
2570 South Miller Lane
City/State/zip: Las Vegas NV 89117 Phone:702-365-8080
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Compliance is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification
identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements
specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the
construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)approved by the enforcement agency.
5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the
building, and made available to the enforcement agency for all applicable inspections.I understand that a registered copy of this Certificate of
Verification is required to be included with the documentation the builder provides to the building owner at occupancy.
Builder Or Installer Information As Shown On The Certificate Of Installation
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): AIREFORCE HEATING & AIR INC
Responsible Builder or Installer Name:CSLB License:
Michelle Sanchez
HERS Provider Data Registry Information
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
217-00815 Not tested
HERS Rater Information
HERS Rater Company Name:Energy Inspectors
Responsible Rater Name:Responsible Rater Signature:
Joseph Schwartz g)ainaNtamiack
Responsible Rater Certification Number w/this HERS Provider:Date Signed:
CC2004506 2017-02-21 12:43:12
Digitally signed by CalCERTS.This digital signature is provided in order to secure the content ofthis registered document, and in no way implies
Registration Provider responsibility for the accuracy ofthe information.
Registration Number: 215-N0163349D-M2000015A-M20A Registration Date/Time:2017-02-21 12:43:12 HERS Provider:CalCERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2017-02-21 11:39:10
2013 Residential Compliance Schema Version: 0.52SDD
CERTIFICATE OF VERIFICATION CF3R-MCH-23-H
Space Conditioning System Airflow Rate (Page 1 of 1)
Project Name:The Vistas at Robertson Ranch Enforcement Agency:City of Permit Number:CB163162
Carlsbad
Dwelling Address:2649 Wadsworth Street City:Carlsbad Zip Code:92010
HERS measure was verified using the methodology defined for the untested features included in a sample group.
This measure passes through its relationship with the actual one tested and passed. Therefore no data is included
on this Certificate of Verification.
Documentation Author's Declaration Statement
1.I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Lorena Pichardo „"evreitorPiciair.4-
Company:Energy Inspectors Date Signed:
Address:CEA/ HERS Certification Identification (i?Pp1pTicalFe)?1 12:29:13
2570 South Miller Lane
City/State/zip: Las Vegas NV 89117 Phone:702-365-8080
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Compliance is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic resultsthat require HERS verification
identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements
specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the
construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)approved by the enforcement agency.
5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the
building, and made available to the enforcement agency for all applicable inspections.I understand that a registered copy of this Certificate of
Verification is required to be included with the documentation the builder provides to the building owner at occupancy.
Builder Or Installer Information As Shown On The Certificate Of Installation
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): AIREFORCE HEATING & AIR INC
Responsible Builder or Installer Name:CSLB License:
Michelle Sanchez
HERS Provider Data Registry Information
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
217-00815 Not tested
HERS Rater Information
HERS Rater Company Name:Energy Inspectors
Responsible Rater Name:Responsible Rater Signature:
Daniel Granback g)01111eiNecuidack•
Responsible Rater Certification Number w/this HERS Provider:Date Signed:
CC2004061 2017-02-21 12:43:12
Digitally signed by CaICERTS.This digital signature is provided in order to secure the contentofthis registered document, and in no way implies
Registration Provider responsibility for the accuracy ofthe information.
Registration Number: 215-N0163349D-M2300014A-M23A Registration Date/Time:2017-02-21 12:43:12 HERS Provider:CaICERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2017-02-21 11:51:41
2013 Residential Compliance Schema Version: 0.52SDD
mum=
CERTIFICATE OF VERIFICATION CF3R-MCH-23-H
Space Conditioning System Airflow Rate (Page 1 of 1 j
Project Name:The Vistas at Robertson Ranch Enforcement Agency:City of Permit Number:CB163162
Carlsbad
Dwelling Address:2649 Wadsworth Street City:Carlsbad Zip Code:92010
HERS measure was verified using the methodology defined for the untested features included in a sample group.
This measure passes through its relationship with the actual one tested and passed. Therefore no data is included
on this Certificate of Verification.
Documentation Author's Declaration Statement
1.I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Lorena Pichardo „.epee&a/Pcc71.0.44-
Company:Energy Inspectors Date Signed:2017 Q2 21 12:29:13Address:CEA/HERS Certification Identification (it appiicanie):
2570 South Miller Lane
City/State/Zip: Las Vegas NV 89117 Phone:702-365-8080
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Compliance is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater).
3.The installed features, materials, components, manufactured devices, or system performancediagnostic results that require HERS verification
identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements
specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the
construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)approved by the enforcement agency.
5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the
building, and made available to the enforcement agency for all applicable inspections.I understand that a registered copy of this Certificate of
Verification is required to be included with the documentation the builder provides to the building owner at occupancy.
Builder Or Installer Information As Shown On The Certificate Of Installation
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): AIREFORCE HEATING &AIR INC
Responsible Builder or Installer Name:CSLB License:
Michelle Sanchez
HERS Provider Data Registry Information
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
217-00815 Not tested
HERS Rater Information
HERS Rater Company Name:Energy Inspectors
Responsible Rater Name:Responsible Rater Signature:
Daniel Granback g)/2/12ZeeNtcodack
Responsible Rater Certification Number w/this HERS Provider:Date Signed:
CC2004061 2017-02-21 12:43:12
Digitally signed by CalCERTS.This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracyof the information.
Registration Number: 215-N0163349D-M2300015A-M23A Registration Date/Time:2017-02-21 12:43:12 HERS Provider:CalCERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2017-02-21 11:53:19
2013 Residential Compliance Schema Version: 0.52SDD
•
CERTIFICATE OF VERIFICATION CF3R-MCH-22-H
Space Conditioning System Fan Efficacy (Page 1 of 1)
Project Name:The Vistas at Robertson Ranch Enforcement Agency:City of Permit Number:CB163162
Carlsbad
Dwelling Address:2649 Wadsworth Street City:Carlsbad Zip Code:92010
HERS measure was verified using the methodology defined for the untested features included in a sample group.
This measure passes through its relationship with the actual one tested and passed. Therefore no data is included
on this Certificate of Verification.
Documentation Author's Declaration Statement
1.I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Lorena Pichardo -,esizeitorPieZvx41.-
Company:Energy Inspectors Date Signed:2017 02 21 12:29:13Address:CEA/HERS Certification Identification (ir appiicaoie):
2570 South Miller Lane
City/state/zip: Las Vegas NV 89117 Phone:702-365-8080
Responsible Person's Declaration statement
I certify the following under penalty of perjury. under the laws of the State of California:
1.The information provided on this Certificate of Compliance is true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic resultsthat require HERS verification
identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements
specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the
construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)approved by the enforcement agency.
5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the
building, and made available to the enforcement agency for all applicable inspections.I understand that a registered copy of this Certificate of
Verification is required to be included with the documentation the builder provides to the building owner at occupancy.
Builder Or Installer Information As Shown On The Certificate Of Installation
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): AIREFORCE HEATING &AIR INC
Responsible Builder or Installer Name:CSLB License:
Michelle Sanchez
HERS Provider Data Registry Information
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
217-00815 Not tested
HERS Rater Information
HERS Rater Company Name:Energy Inspectors
Responsible Rater Name:Responsible Rater Signature:
Daniel Granback g)COteeNta/niek
Responsible Rater Certification Numberw/this HERS Provider:Date Signed:
CC2004061 2017-02-21 12:43:12
Digitally signed byCalCERTS.This digital signature is provided in order to secure the content ofthis registered document, and in no way implies
Registration Provider responsibility for the accuracyofthe information.
Registration Number: 215-N0163349D-M2200014A-M22A Registration Date/Time:2017-02-21 12:43:12 HERS Provider:CaICERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2017-02-21 11:56:38
2013 Residential Compliance Schema Version: 0.52SDD
Agoommumi
CERTIFICATE OF VERIFICATION CF3R-MCH-22-H
Space Conditioning System Fan Efficacy (Page 1 of 1)
Project Name:The Vistas at Robertson Ranch Enforcement Agency:City of Permit Number:CB163162
Carlsbad
Dwelling Address:2649 Wadsworth Street City:Carlsbad Zip Code:92010
HERS measure was verified using the methodology defined for the untested features included in a sample group.
This measure passes through its relationship with the actual one tested and passed. Therefore no data is included
on this Certificate of Verification.
Documentation Author's Declaration Statement
1.I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Lorena Pichardo -,dveeita.Pcdta.44.-
Company:Energy Inspectors Date Signed:
Address:CEA/ HERS Certification Identification (inpIpTicalYe)?1 12:29:13
2570 South Miller Lane
City/State/zip: Las Vegas NV 89117 Phone:702-365-8080
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of Compliance is true and correct.
2.I am the certified HERS Rater whoperformed the verification identified and reported on this Certificate of Verification (responsible rater).
3.The installed features, materials, components, manufactured devices, or system performance diagnostic resultsthat require HERS verification
identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements
specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the
construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CF1R)approved by the enforcement agency.
5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the
building, and made available to the enforcement agency for all applicable inspections.I understand that a registered copy of this Certificate of
Verification is required to be included with the documentation the builder provides to the building owner at occupancy.
Builder Or Installer Information As Shown On The Certificate Of Installation
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): AIREFORCE HEATING & AIR INC
Responsible Builder or Installer Name:CSLB License:
Michelle Sanchez
HERS Provider Data Registry Information
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
217-00815 Not tested
HERS Rater Information
HERS Rater Company Name:Energy Inspectors
Responsible Rater Name:Responsible Rater Signature:
Daniel Granback g)0/12aNta/niack-
Responsible Rater Certification Numberw/this HERS Provider:Date Signed:
CC2004061 2017-02-21 12:43:12
Digitally signed by CalCERTS.This digital signature is provided in order to secure the content ofthis registered document, and in no way implies
Registration Provider responsibility for the accuracyofthe information.
Registration Number: 215-N0163349D-M2200015A-M22A Registration Date/Time:2017-02-21 12:43:12 HERS Provider:CalCERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2017-02-21 11:59:17
2013 Residential Compliance Schema Version: 0.52SDD
-/00.0••••••••••••immi
CERTIFICATE OF VERIFICATION CF3R-MCH-27-H
Indoor Air Quality and Mechanical Ventilation (Page 1 of 1)
Project Name:The Vistas at Robertson Ranch Enforcement Agency:City of Permit Number:CB163162
Carlsbad
Dwelling Address:2649 Wadsworth Street City:Carlsbad Zip Code:92010
HERS measure was verified using the methodology defined for the untested features included in a sample group.
This measure passes through its relationship with the actual one tested and passed. Therefore no data is included
on this Certificate of Verification.
Documentation Author's Declaration Statement
1.I certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Lorena Pichardo ..esvee&a/Piciair.4-
Company:Energy Inspectors Date Signed:2017 Q2 21 12:2913Address:CEA/HERS Certification Identification (ir appiicaloie):
2570 South Miller Lane
city/State/zip: Las Vegas NV 89117 Phone:702-365-8080
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1.The information provided on this Certificate of ComplianceIs true and correct.
2.I am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater).
3.The installed features, materials, components, manufactured device% or system performancediagnostic results that require HERSverification
identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements
specified on the Certificate of Compliance for the building approved by the enforcement agency.
4.The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the
construction or installation conforms to the requirements specified on the Certificate(s) of Compliance(CF1R)approved by the enforcement agency.
5.I will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s) issued for the
building, and made available to the enforcement agency for all applicable inspections.I understand that a registered copy of this Certificate of
Verification is required to be included with the documentation the builder provides to the building owner at occupancy.
Builder Or Installer Information As Shown On The Certificate Of Installation
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): AIREFORCE HEATING & AIR INC
Responsible Builder or Installer Name:CSLB License:
Michelle Sanchez
HERS Provider Data Registry Information
Sample Group Number (if applicable):Dwelling Test Status in Sample Group (if applicable)
217-00815 Not tested
HERS Rater Information
HERS Rater Company Name:Energy Inspectors
Responsible Rater Name:Responsible Rater Signature:
Daniel Granback Nte2//dadResponsible Rater Certification Number w/this HERS Provider:Date Signed:
CC2004061 2017-02-21 12:43:12
•Digitally signed by CaICERTS.This digital signature is provided in order to secure the content of this registered document, and in no way implies
•
Registration Provider responsibility for the accuracyof the information.
Registration Number: 215-N0163349D-M2700013A-M27A Registration Date/Time:2017-02-21 12:43:12 HERS Provider:CaICERTS
•CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.008 Report Generated: 2017-02-21 12:01:56
2013 Residential Compliance Schema Version: 0.52SDD
CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING Additional Energy Features
Additional Energy Feature Verification (Page 1 of 1)
Project Address:2649 Wadsworth Street Carlsbad CA,92010 Builder Name:Toll Brothers, Inc.-Southern CA
Builder Contact:na Telephone:999-999-9999
Plan Number:ToII147 Plan 4 Standard Sample Group Number:217-00815 Sample House Number:1017931
HERS Rater:Daniel Granback Telephone:702-365-8080
Certifying Signature:gli/na Ntainsack Date:2017-02-21 12:02:00
Firm:Energy Inspectors HERS Provider:CaICERTS inc.
Street Address:2570 South Miller Lane city/state/zip:Las Vegas /NV /89117
HERS measure was verified using the methodology defined for the untested features included
in a sample group.
This measure passes through its relationship with the actual one tested and passed.
Therefore no data is included on this Certificate of Verification.
1a) Radiant Barrier Required:N/A
1 b) Was the Radiant Barrier installed?N/A
2) Opaque Surfaces:N/A
3) Glazing (Window) Values:N/A
4) HVAC Efficiency:N/A
5) Verify Water Heater Efficiency:N/A