HomeMy WebLinkAbout2650 Acuna Ct; ; CBR2017~0423; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Print Date: 03/13/2017 Residential Permit Permit No: CBR2017-0423
www.carlsbadca.gov
Job Address:2650 Acuna Ct
Permit Type:BLDG-Residential Work Class:P/M/E Status:Closed -Finaled
Parcel No:2154912100 t Lot U:Applied:03/02/2017
Valuation:$0.00 Reference ft:Issued:03/02/2017
Occupancy Group:Construction Type:Finaled:
U Dwelling Units:Bathrooms:Inspector:
Bedrooms:Orig. Plan Check U:
Plan Check U:
Project Title:
Description:ANDERS: REPLACE FAU
Owner:Contractor:
TRUST ANDERS FAMILY TRUST 04-27-05 COASTAL REFRIGERATION
2650 Acuna Ct
CARLSBAD, CA 92009 6525 Paseo Frontera, Apt L
Carlsbad, CA 92009-4534
760-683-5683
PLUMBING, ELECTRICAL, AND MECHANICAL PERMIT $166.00
Total Fees:$166.00 Total Payments To Date:$166.00 Balance Due:$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction."You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLYto water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project.NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE:0 PLANNING 0 ENGINEERING 0 BUILDING 0 FIRE 0 HEALTH 0 HAZMAT/APCD
(i;l';C.
•
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
Plan Check No.06 RIC)11-042.3ofEst. Value
Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. DepositCalsbd.email: building@carlsbadca.gov
www.carlsbadca.gov Date 3-2.-
1 -4 SWPPP
---
1
SUITEWSPACEVUNIT#APNJOBADDREre5.--:5 ife ciex/e.__
CT/PROJECT#LOT#PHASE t #OF UNITS #BEDROOMS #BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE 'OCC. GROUP
i
DESCRIPTION OF WORK:Include Square Feet of Affected Area(s)
/2e;.74te ee."(i. 4ii.7—i4 e-e 5-27.fri_e i.ledete0 .e;e....
EXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE AIR CONDITIONING FIRE SPRINKLERS
YESD.NOD YES ElNO ID YESID NOD
APPLICANT NAME PROPERTY OWNER
Primary Contact //eP #..e'deei:ADDRESS ADDRESS b.s-d
/7(9(42....rf.
Cre.-
CITY STATE ZIPZtpm
CITY"4. s....4.0.0d 7.0020•DiPHONEFAX
ityLliE:)641 ....•y y/.'FAX
EMAIL kf...MAIL
9
....-•"")DESIGN PROFESSIONA-CONTRACTOR BUS.
NeE 5".41/4447‘,)rof/.-4
ADDRESS ADDRESS
---
goliye...._°74
---itAf/Pe-4.-..7-
CITY STATE ZIP CITY j_,--45V --f/STA
4e
ZIP
PHONE FAX ON 9.0?oe.F
E2
FAXFAX
C.2760EMAILMAIL
STATE LIC.#STATE ? 7/r.2..c.:',Il CITY BUS. 11;,/>e2(7.2
(Sec.7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires theapplicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) orthat he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to acivil penalty of not more than five hundred dollars p5ooD.
WORKERS'COMPENSATION
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
ave and will maintain a certificateof consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
I I have and will maintain workers'n U reo4td by Section 3700 of the Labor Code, for the performance of the work for whic this permit is issued.workers' compensation 'ance c and policy
1number are: Insurance Co./Y7 ..Policy No.7 46VAX.Cef W/T Expiration Date 4.
1hi section need not be completed if the permit isfor one hundred dollars ($100) or less.
Certificate ofExemption:I certify that in the perfo i .nce of the work for which this permit is issued,I shall not employ any person in any'manner so as to become subject to the Workers' Compensation Laws of
1 California.WARNING: Failure to secure workers' j.I pensation coverag.is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
i addition to the cost of compensation, d .0 ,4rovided for•.S....706ofthe Labor code, interest and attorney's fees.
1 Arc CONTRACTOR SIGNATURE _-,‘,../../.'a(.......•"----0 AGENT DATE 3 42 ;di/ 7
11 OWNER -BUILDER fiECLARATION
i ,
I hereby affirm that I am exempt from Con...s License Law for the following mason:I1:1 I,as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
i 0 I,as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
'l
i property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).0 I am exempt under Section Business and Professions Code for this reason:
1.I personally plan to provide the major labor and materials for construction ofthe proposed property improvement.DYes EjNo
om 2.1 (have /have not) signed an application for a building permit for the proposed work.
3.I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number):
II 4.I plan to provide portionsofthe work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number):
5.I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address Iphone I type of work):
ri Itf.MNIT ISATL
COMPLETE THIS SECT/ON FOR NON -RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act?0 Yes 0 No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?0 Yes No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?0 Yes 0 No
IFANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lenders Name Lenders Address
APPLICANT CERTIFICATION
Icertify thatIhave read the application and state that the above information is correct and that the Information on the plans Is accurate.Isweet°comply with all City oillnances and State laws relating to building construction.
Ihereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspedion purposes.IALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over50'r'.r and demolition or construction of skuctues over 3 stories in height
EXPIRATION: Every permit issued by the Buildir .1 lire pmvisions of this Code shall expire by Imitationaidbecome null and void if the building or wodc authorized by such permit is not commenced within
180 days from the dateofsuch permit orif •wilding rier authorized stir-.•••or abandoned atan/ tine after the work is commenced for
•180 days (Section106A.4 Uniform Building Code).
,'APPLICANT'S SIGNATURE ;DATE .1)aot /-
1
STOP
STOP:THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE.
Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection.
Fax (760) 602-8560, Email buildingecarlsbadcagov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008.
•CO#:(Office Use Only)
CONTACT NAME OCCUpANT NAME
ADDRESS BUILDING ADDRESS
CITY STATE ZIP CITY STATE ZIP
Carlsbad CA •
PHONE FAX
I.
EMAIL OCCUPANT'S BUS. LIC. No.
DELIVERY OPTIONS
0 PICK UP:o CONTACT (Listed above)o OCCUPANT (Listedabove)
n CONTRACTOR (On P.1)
ASSOCIATED CB#0 MAILTO:o CONTACT (Listed above)o OCCUPANT (Listed above)
o CONTRACTOR (On Pg. 1) NO CHANGE IN USE/NO CONSTRUCTION
0 MAIL/FAX TO OTHER:
Er CHANGE OF USE /NO CONSTRUCTION
ASAPPLICANT'S SIGNATURE DATE
.—-Neseemoussimesilalliglingl
PERMIT INSPECTION HISTORY REPORT (CBR2017-0423)
Permit Type:BLDG-Residential Application Date:03/02/2017 Owner:TRUST ANDERS FAMILY TRUST
04-27-05
Work Class:P/M/E Issue Date:03/02/2017 Subdivision:
Status:Closed -Fineled Expiration Date:09/11/2017 Address:2650 Acuna Ct
Carlsbad, CA 92009-6401
IVR Number:2232
Scheduled Actual
Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete
03/1312017 03113/2017 BLDG-43 Air 016239-2017 Passed Andy Krogh Complete
Cond./Furnace Set
BLDG-Final 016240-2017 Passed Andy Krogh Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Mechanical Final Yes
March 13, 2017 Page 1 of 1
CERTIFICATE OF INSTALLATION CF2R-M04-20-H
Duct Leakage Diagnostic Test (Page 1 of 3)
Project Name:Anders Enforcement Agency:City of Permit Number:cbr2017-0423
Carlsbad
Dwelling Address:2650 Acuna ct City:Carlsbad Zip Code:92009
A. System Information
01 Space Conditioning System Identification or Name System 1
02 Space Conditioning System Location or Area Served Location 1
03 Building Type from CF-1R Single family
Verified Low Leakage Ducts in Conditioned Space (VLLDCS)No, credit is not taken04Credit from CF1R?
05 Verified Low Leakage Air Handling Unit (VLLAHU) Credit No, credit is not taken
from CF1R?
06 Duct System Compliance Category Alteration using smoke test
MCH-20e -Sealing All Accessible Leaks using SmokeTest
B.Duct Leakage Diagnostic Test
01 Condenser Nominal Cooling Capacity (ton)0
02 Heating Capacity (kBtu/h)71
1
03 Conditioned Floor Area served by this HVAC system (ft2)2500
04 Duct Leakage Test Conditions Test final
05 Duct Leakage Test Method Total leakage
06 Leakage Factor 0.15
07 Air Handling Unit Airflow (AHUAirflow) Determination Heating system method
Method
08 Measured AHUAirflow This field or section is not applicable
09 Calculated Target Allowable Duct Leakage (cfm)231
10 Actual Duct Leakage Rate from Leakage Test Measurement 418
(cfm)
Registration Number:Registration Date/Time:2017-03.09 09:50:37 HERS Provider:CaICERTS
217-A020076629A-000-001-M20001A-0000
CA Building Energy Efficiency Standards Report Version: 2016.1.005 Report Generated: 2017-03-09 09:51:40
2016 Residential Compliance Schema Version: rev 03/16
CERTIFICATE OF INSTALLATION CF2R-MCH-20-H
Duct Leakage Diagnostic Test (Page 2 of 3)
B.Duct Leakage Diagnostic Test
System passes using smoke test of an altered HVAC system
in an existing building. No visible smoke exits the accessible
portions of the duct system. Smoke is only emanating from
air-handling unit (AHU) cabinet and non accessible portions
11 Compliance Statement:of the duct system. Note -Accessible is defined as having
access thereto, but which first may require removal or
opening of access panels, doors, or moving similar
obstructions. If access to the ducts requires an object to be
demolished or deconstructed then sealing of those ducts is
not required
C.Additional Requirements for Compliance
01 System was tested in its normal operation condition. No temporary taping allowed.
Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage
02 testing. OA ducts used for Central Fan Integrated (CFI)Indoor Air Quality ventilation systems, or Central Fan Ventilation
Cooling Systems,that utilize dampers that open only when OA is required and automatically close when OA is not required,
may configure the OA damper to the closod position diving duCt kokage test*.
03 All supply and return regkaer ()cots were sealed to thO'dr*otall.
04 Building cavities were not used is plenurrLs4 platform returns in lieu of ducts.
05 If cloth backed tape was used it was covered with Mastic and draw bands.
06 All connection points between the air handler and the supply and return plenums are completely sealed.
If the system complies using the Smoke Test method, the smoke test was conducted in accordance with the requirements of
07 Reference Residential Appendix RA3.1.4.3.6. Systems that comply using smoke test shall not be included in sample groups
for HERS verification compliance.
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have
been met.
Registration Number:Registration Date/Time:2017-03-09 09:50:37 HERS Provider:CaICERTS
217-A020076629A-000-001-M20001A-0000
CA Building Energy Efficiency Standards Report Version: 2016.1.005 Report Generated: 2017-03-09 09:51:40
2016 Residential Compliance Schema Version: rev 03/16
CERTIFICATE OF INSTALLATION CF2R-MCH-20-H
Duct Leakage Diagnostic Test (Page 3 of 3)
Documentation Author's Declaration Statement
1.I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:Documentation AuthorSignature:gezemeedw.Seth Woolson
Company:Signature Date:2017-03-09 09:50:37COASTAL REFRIGERATION_HEATING & CONDITIONING
Address:CEA/ HERS Certification Identification (if applicable):
6525 PASEO FRONTERA UNIT I
City/State/Zip:Phone:
CARLSBAD CA 92009 760-683-5683 X123
Responsible Person's Declaration statement
I certify the following under penalty ofperjury, under the laws of the State ofCalifornia:
1.The information provided on this Certificate of Installation is true and correct.
2.I am either: a) a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classification to accept
responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work
identified on this Certificate of Installation and attest to the declarations in this statement, orb)I am an authorized representative of the responsible
person and attest to the declarations in this statement on the responsible person's behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificateof Installation
conforms to all applicable codes and regulations and the installation conforms to the requirements given on the Certificate of Compliance, plans, and
specifications approved by the enforcement,ncy.
4.I understand that a HERS rater will check th stallation to vOr'cottpliance andifsucl4hecking determines the installattep f s to Comply,I am
required to offer any neceslary Oprrective a n at nochar uilding Omer.
5.I will ensure that a registerkpepy Of this Ce of fti•shilllioposliedror node available with thebuilding perAit(4issuedfor the
building, and made available to:theiknfomement agency for all applicable inspectiorts4underispind that a reeistered copyofthis Certificateof
Installation is required to be included with the clocUmentation the'builderprovides to the betiding Owner at cotipanty.
Responsible Builder/Installer Name:Responsible Builder/Installer Signature:
Seth Woolson
Company Name: (Installing Subcontractor or General Contractor or Position With Company (Title):
Builder/Owner)Owner
•COASTAL REFRIGERATION_HEATING & CONDITIONING
Address:CSLB License:
6525 PASEO FRONTERA UNIT I 974929
City/State/Zip:Phone:Date Signed:
CARLSBAD CA 92009 760-683-5683 X123 2017-03-09 09:50:37
Third Party Quality Control Program (TPQCP) Status:Nameof TPQCP (ifapplicable):
Digitally signed byCalCERTS.This digital signature is provided in order to secure the contentofthis registered document and in no way implies
Registration Provider responsibility for the accuracyofthe information.
Registration Number:Registration Date/Time:2017-03-09 09:50:37 HERS Provider:CaICERTS
217-A020076629A-000-001-M20001A-0000
CA Building Energy Efficiency Standards Report Version: 2016.1.005 Report Generated: 2017-03-09 09:51:40
2016 Residential Compliance Schema Version: rev 03/16
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 1 of 7)
Project Name:Anders Enforcement Agency:City of Carlsbad Permit Number:cbr2017-0423
Dwelling Address:2650 Acuna ct City:Carlsbad Zip Code:92009
A. General Information
01 Dwelling Unit Name Anders 02 Climate Zone 7
Dwelling Unit Total Conditioned Floor Number of Space Conditioning03500004 1Area (ft2)Systems In this Dwelling Unit.
05 Certificate of Compliance Type Prescriptive alterations (CF1R-ALT )06 Method Used to Calculate HVAC Loads NotApplicableEquipmentChangeout
Calculated Dwelling Unit Sensible Calculated Dwelling Unit Heating Load07Cooling Load (Btu/h)(Btu/h) Thisfield or section is not applicable 08 This field or section is not applicable
09 Dwelling Unit Number of Bedrooms 3
.,...
MCH-01b -Space Conditioning Systems Ducts amid Fans -Prescriptive Altwations--
.
B. Space Conditioning (SC)System Information
!
01 02 03 04 05 06 07 08 09 10
CFA served N the SC Installing a Installing
SC System SC System by this SC system a refrigerant Installing new SC Installing more entirely Installing
Identification or Location or Area System ducted containing system than 40 feet of new duct entirely new
Name Served (ft2)system?component?components?ducts?system?SC system?Alteration Type
....
Altered space
System 1 Location 1 2500 Yes No Yes No No No conditioning
system
Registration Number: 217-A020076629A-000-001-M01001A-0000 Registration Date/Time:2017-03-09 09:50:37 HERS Provider:CaICERTS
CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-03-09 09:50:59
Schema Version: rev 10/16
.......,..---
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 2 of 7)
C. Space Conditioning (SC) System Alterations Compliance information
01 02 03 04 05 06 07 08 09 —10 11 12 13,.
Central Fan
Integrated
Heating Cooling New or (CFI)
SC Altered Heating Minimum Altered Cooling Minimum Required Replaced New Ventilation
Identification Heating Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Duct Duct System
or Name System Type Component Type Value System Type Component Type Value Type Length R-Value Status
This field
All new orNo coolingCentral gas heating section is Not a CFISystem1AFUE81No cooling component SEER Setback LTE4OFt R6furnacecomponennot systemalteredisapplicabl
e
D.Installed Heating Equipment Information --..
..."-
01 02 03 ---410-—-OS—...DEL 07_,-.•I
Heatiwgl' fRelency -44eaingtinii geatfrig4Tnic Heating-Unit Serial Rated Heating Capacity,
SC Identification or Name Heating Efficiency Typo.,Value,-Manufacturer Model Number Number Output (Btu/h)
..
System 1 AFUE 81 AC PRO 80g1uh090bp161 1716h01658 71000
Notes:
E.Installed Cooling Equipment Information
This section does not apply to this project.
F.Extension of Existing Duct System, Greater Than 40 Feet
This section does not apply to this project.
Registration Number: 217-A020076629A-000-001-M01001A-0000 Registration Date/Time:2017-03-09 09:50:37 HERS Provider:CaICERTS
CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-03-09 09:50:59
Schema Version: rev 10/16
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 3 of 7)
G. Installed Duct System Information
This section does not apply to this project.
H.Installed Air Filter Device information
This section does not apply to this project.
I.Air Filter Device Requirements
This section does not apply to this project.
Registration Number: 217-A020076629A-000-001-M01001A-0000 Registration Date/Time:2017-03-09 09:50:37 HERS Provider:CaICERTS
CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-03-09 09:50:59
Schema Version: rev 10/16
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 4 of 7)
J. HERS Verification Requirements
01 02 03 04 05 06 07 08 09 10—
Exemption
MCH-20 from MCH-23MinimumMCH-22 M01-25
Exemption R-Value for MCH-21 AHU MCH-28
SC System SC System From Duct Duct Ducts in AHU Fan Airflow
Identification or Location or Area Leakage Leakage Conditioned Duct Location Efficacy Rate Refrigerant Return Duct Design
Name Served Requirements Test Space Verification (W/cfm)(dm/ton)Charge -Table 150.0-8 or C
No NotSystem1Location1Yes No No No No Noexemptionsapplicable
Notes:
1
Registration Number: 217-A020076629A-000-001-MO1001A-0000 Registration Date/Time:2017-03-09 09:50:37 HERS Provider:CaICERTS
CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-03-09 09:50:59
Schema Version: rev 10/16
-
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 5 of 7)
K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures
Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the
system that are altered. Existing equipment may be exempt from these requirements.
Heating Equipment
01 Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency
Regulations.
02 Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant
to program the temperature set points for at least four different periods in 24 hours.See Sections 150.0(i), 110.2(b).
03 Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections
150.0(h)1 and 2).
Furnace Temperature Rise: Central forced-air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum04inlet-to-outlet temperature rise specification.See Section 150.0(h)4.
OS Standby Losses and Pilot Lights: Fan-type central furnacesiivarnot have.' continuousfyburgingollotjfght,,,,SeCtion 1104 and Section 110.2(d).
Cooling Equipment
Equipment Efficiency: All cooling equipment must meet the minimum efficiency requirements cif Section 110.1 and Section 110.2(a) and the Appliance Efficiency06Regulations.
07 Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R-value and protection requirements of Section
150.0(1)2 and 3, and Section 150.0(m)9.
08 Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet.See Section 150.0(h)3A.
09 Liquid Line Filter Drier:if applicable,a liquid line filter drier shall be installed according to the manufacturer's specifications. Section 150.0(h)3B
10 Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section
150.0(h)1 and 2.
Air Distribution System Ducts, Plenums and Fans
Registration Number: 217-A020076629A-000-001-M01001A-0000 Registration Date/Time:2017-03-09 09:50:37 HERS Provider:CaICERTS
CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-03-09 09:50:59
Schema Version: rev 10/16
CERTIFICATE OF INSTALLATION
CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans
(Page 6 of 7)
K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures
Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicableto some systems. These requirements may be applicable to only newly installed equipment or portions of the
system that are altered. Existing equipment may be exempt from these requirements.
Insulation: In all cases, unless ducts are enclosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be
11 required by the prescriptive or performance requirements.See Section 150.0(m)1.
Connections and Closures: All installed air-distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0,
602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply-air and return-air ducts and plenums must be insulated to a minimum installed level of R-6.0 or
12 enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference
Residential Appendix RA3.1.4.3.8.
Heat Pump Thermostat
13 A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c).
14 The thermostat shall be installed in accordance with the manufacturers published installation specifications
15 First stage of heating shall be assigned to heat pump heatjrig.
16 Second stage back up heating shall be set come on only when the)ndoor.set terneeraturs cannot it met
The responsible person's signature on this complianceilocument affirms that all applicable requirements in 'his table have been met.
Registration Number: 217-A020076629A-000-001-M01001A-0000 Registration Date/Time:2017-03-09 09:50:37 HERS Provider:CaICERTS
CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-03-09 09:50:59
Schema Version: rev 10/16
__—
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 7 of 7)
Documentation Author's Declaration Statement
1.I certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:swieiSeth Woolson
Company:Signature Date:
COASTAL REFRIGERATION_HEATING & CONDITIONING 2017-03-09 09:50:37
Address:CEA/ HERS Certification Identification (if applicable):
6525 PASEO FRONTERA UNIT I
City/State/Zip:Phone:
CARLSBAD CA 92009 760-683-5683 X123
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1.The Information provided on this Certificate of Installation is true and correct.
2.I am either: a)a responsible person eligible under Division 3 of the Business and Professions Code in the applicable classificationto accept responsibility for the system design, construction, or installation of
features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attestto the declarations in this statement, or b)I am an authorized
representative of the responsible person and attest to the declarations this statementon,the fespoesibie parkin.; behalf.
3.The constructed or installed features, materials, components or manufactured devices (the installaticibj itentined oft this Certificate of Installation corderresto a*Olicable codes and regulations and the
installation conforms to the requirements given on the:Certificate of Compliapee, plans. are! specifications apptoved by the enforcement agency.
4.I will ensure thata registered copy of this Certificaptof lastallation sbaltbatposted or made available with the building permits) issuerifor the buntline. ancrmade available to the enforcement agency for all
applicable inspections.I understand that a registeredapy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Builder/Installer Name:Responsible Builder/Installer Signature:
Seth Woolson _Se&ifieci&ti.
Company Name: (installing Subcontractor or General Contractor or Builder/Owner)Position With Company (Title):
COASTAL REFRIGERATION_HEATING & CONDITIONING Owner
Address:CSLB License:
6525 PASEO FRONTERA UNIT I 974929
City/State/Zip:Phone:Date Signed:
CARLSBAD CA 92009 760-683-5683 X123 2017-03-09 09:50:37
Digitally signed by CaICERTS.This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider
responsibility for the accuracyof the information.
Registration Number: 217-A020076629A-000-001-M01001A-0000 Registration Date/Time:2017-03-09 09:50:37 HERS Provider:Ca10ERTS
CA Building Energy Efficiency Standards -2016 Residential Compliance Report Version: 2016.1.005 Report Generated: 2017-03-09 09:50:59
Schema Version: rev 10/16
_.—_