Loading...
HomeMy WebLinkAbout2653 Obelisco Pl; ; CBR2019-0065; PermitPrint Date: 10/11/2019 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2653 Obelisco Pl BLDG-Residential 2154400700 $50,075.00 Residential Permit Work Class: Deck Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: (city of Carlsbad Permit No: CBR2019-0065 Status: Applied: Issued: Permit Finaled: Closed -Finaled 01/09/2019 02/21/2019 Inspector: PBurn Final Inspection: 10/11/2019 ll:39:44A Description: PELLATON: REBUILD 2,500 SF DECK 5FT ABOVE GRADE AROUND SWIMMING POOL BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Owner: ERIC PELLATON 2653 Obelisco Pl CARLSBAD, CA 92009 SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $707.24 Total Payments To Date: $707.24 Balance Due: $0.00 $410.43 $287.30 $3.00 $6.51 Please take NOTICE that approval of your project includes the "lmposition11 of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov {'cicyof Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION 8-1 Plan Check Est. Value PC Deposit ----rc=-+·--,,-- Date _!Lf-/'t..:.+/_._lq...__ Job Address CT /Project#: 2-l1? Of.l.Ll.tc~ />I~ Oa 'rl.f/fAJ, __ APN: -:u.S LJ.l/oP7t?o relJu : l"J) M_L Lot#: 6 7 If: ,.,.~irl ?/.iKklers: yes/ ,)9 Air Conditioning: yes/~ BRIEF DESCRIPTION OF WORK: 'r€Ru)/J,,'y ~I; a---✓ol ;r,,.,,:..wa-t~ (J./r,>#Jf) 0 Addition/New: _____ .Living SF, ____ Deck SF, ____ Patio SF, ____ Garage SF Is this to create an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __ D Remodel: ____ SF of affected area Is the area a conversion or change of use? Yes/ No □ Pool/Spa: ____ SF Additional Gas or Electrical Features? ____________ _ D Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground, Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No Panel Upgrade: Yes/ No D Reroof: ___________________________________ _ D Plumbing/Mechanical/Electrical Only: --------------~,.,.._~-------~ Other: tliQ1,1,; /J,';r ct,v:.....,..,..;4= pwt !7?ee~ ,~ ~tit.) APPLICANT (PRIMARY) PROPERTY OWNER Name: /\(t'"1-fc Ll Name: , af<,/C, R~W:Tm Address:,&,, ~.,/Je"' Scvk A-CA.e.. Address: ,-b-13 O/!,"ZLl>I& P/Ne City: ak/etV,',-f:Df. State:M Zip: 9t<1/~ City: em,a.a Stat;c/4--Zip: '7'2,-r"J Phone: 8,tg '$Bo ,61z...r Phone: )h8tJ:'ill:2'j Email: ya.yclrorf:t,""nJ@)yak"TJ, c,, ... , Email: ________________ _ DESIGN PROFESSIONAL I J I p Name: /:)p.,t,~ n,uAl'g- Address: /~J~& JeH Jll,#e ,4i,u__ City: t/41,l~ t/i], State: ~ip: 91 <Jt ~ Phone: ?? ~/~ CONTRACTOR BUSINESS Name: .,_ r-c. W\ Address: ~00 ~ ~\l,J · City: G~\<,\.c,.,X State:._,.'--'--'Zip: Phone: _(;, \ "l~ ~'){8; -(, ':\ bCo Email: n,.yJr;+frn tfeph v.:>, CP1-'"\, Architect State License: __________ _ Email: ,Y:c.,~~'"\-@, 01.A\-\ao\; •= State License: e,eus. License: (3.LO 'i:. 6u :?>\"'~1--C>'-1 · (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any"structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 oft he Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$5001). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-1 Page 1 of 2 Rev. 06/18 ?-cl l~ ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: □ I have and will maintain a certificate of consent to self-Insure for workers' compensation provided by Section 3700 of the labor Code, for the performance of the work which this permit ts Issued. □ I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation Insurance carrier and policy number are: Insurance Company Name: _____________________ _ P r No. Expiration Date: ificate of Exemption: I certify that in the performance of the work for which this permit ls Issued, I shalt not employ any person in any manner so as to be come ~ to the workers' compensation Lawt of California. WARNING: Failure to secure workers compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000,00, In addition the to the cost of compensatl s provided for In Section 3706 of the Labor Code, interest and attorney's fees. &/a-.1 /~9 I ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: □ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or Improve for the purpose of sale). □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). □ I am exempt under Section ________ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (Include name/ address/ phone/ contractors' license number): 5. r will provide some of the work, but I have contracted (hired) the following persons to provide the work Indicated (include name/ address/ phone/ type of work): OWNER SIGNATURE: □AGENT DATE: _____ _ -------------------------- CONSTRUCTION LENDING AGENCY. IF ANY: I hereby affirm that there Is a construction lending agency for the performance of the work this permit is Issued (Sec. 3097 (1) Civil Code). Lender's Name: _____________________ Lender's Address: ____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above Information Is correct and that the Information on the plans ls accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the Oty of carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'0' deep and demolltion or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or If the bulldlng or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). APPLICANT SIGNATURE: J/111.. g... l-, I' 1635 Faraday Ave Carlsbad, CA 92008 8-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of2 DATE: Email: Building@carlsbadca.gov Rev. 06/18 PERMIT INSPECTION HISTORY REPORT (CBR2019-0065) Permit Type: BLDG-Residential Application Date: 01/09/2019 Owner: ERIC PELLATON Work Class: Deck Issue Date: 02/21/2019 Subdivision: LA COSTA MEADOWS #4 Status: Closed -Finaled Expiration Date: 10/22/2019 Address: 2653 Obelisco Pl Carlsbad, CA 92009-6528 IVR Number: 16396 Scheduled Actual Inspection Type Inspection No, Inspection Status Primary Inspector Reinspection Complete Date Start Date 02/22/2019 02/22/2019 BLDG-11 084379-2019 Passed Paul Burnette Complete Foundatlon/Ftg/Pler s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 04/2512019 04/25/2019 BLDG-14 089944-2019 Passed Paul Burnette Complete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 10/11/2019 10/11/2019 BLDG-Final 107389-2019 Passed Paul York Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final No October 11, 2019 Page 1 of 1 DATE: Feb. 7, 2019 JURISDICTION: Carlsbad ✓• EsG1I A SAFEbu1lt Company PLAN CHECK#.: CBR2019-0065 PROJECT ADDRESS: 2653 Obelisco Place SET: II PROJECT NAME: Pellaton Residence Deck Replacement □ APPLICANT □ JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. ~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: Ning Li ~ EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Ning Li Telephone#: (858) 380-6125 Date contacted: (by: ) Email: raydrafting@yahoo.com Mail Telephone Fax In Person ~ ~ REMARKS: Notes have been added to sheet A-2 and clouded in red; pl dd to all plan sets. ·(J By: Chris Shaver Enclosures: EsGil 1/31/2019 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 DATE: Jan.22,2019 JURISDICTION: Carlsbad ✓• EsG1I A SAFEbuilt Compd'<y PLAN CHECK#.: CBR2019-0065 PROJECT ADDRESS: 2653 Obelisco Place SET: I PROJECT NAME: Pellaton Residence Deck Replacement □ APPLICANT □ JURIS. 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. IZJ The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. IZJ The applicant's copy of the check list has been sent to: Ning Li 0 EsGil staff did not advise the applicant that the plan check has been completed. IZJ EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Ning Li Telephone#: (858) 380-6125 Date contacted: (by: ) Email: raydrafting@yahoo.com Mail Telephone 0 REMARKS: By: Chris Shaver EsGil Fax In Person Enclosures: 1/11/2019 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK#.: CBR2019-0065 JURISDICTION: Carlsbad PROJECT ADDRESS: 2653 Obelisco Place FLOOR AREA: 2528 SF REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: Jan.22,2019 FOREWORD (PLEASE READ): STORIES: 1 HEIGHT: 12 FT DATE PLANS RECEIVED BY ESGIL CORPORATION: 1/11/2019 PLAN REVIEWER: Chris Shaver This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Chris Shaver PLAN CHECK#.: CBR2019-0065 DATE: Jan.22,2019 BUILDING ADDRESS: 2653 Obelisco Place BUILDING OCCUPANCY: U BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Deck Reolacemer 2528 20.03 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance ' 1997 UBC Buildin g Permit Fee •1 I 1997 USC Plan Check Fee Type of Review: 1-7 Complete Review r Other Reg. VALUE Mod. r Structural Only r Repetitive Fee I,..: Repeats ' . .. r Hourly EsGil Fee f------1] Hr. @ * Comments: ($) 50,636 50,636 $247.37) Sheet 1 of 1 PLANS 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring IWQ corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. 2. Indicate on the Title Sheet of the plans the name name of the person responsible for the preparation of the plans. Section R 106.1.1. 3. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). This will be verified on each submittal. EXITS, STAIRWAYS, AND RAILINGS 4. Provide stairway and landing details. Section R311.7. a) Maximum rise is 7-3/4" and minimum run is 10", measured from the nosing projection. Where there is no nosing, the minimum run is 11 ". b) Minimum width is 36". c) The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. 5. Open risers are only permitted if the opening between treads does not permit the passage of a 4" diameter sphere. Section R311.7.5.1. CONTINUED 6. Handrails (Section R311.7.8): a) Shall be provided on at least one side of each stairway with four or more risers. b) Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous. c) The handgrip portion of all handrails shall be not less than 1-¼ inches nor more than 2 inches in cross-sectional dimension. See Section R311.7.8.3 for alternatives. d) Handrails projecting from walls shall have at least 1-½ inches between the wall and the handrail. e) Ends of handrails shall be returned or shall have rounded terminations or bends. 7. Every stairway landing shall have a dimension, measured in the direction of travel, at least equal to the stairway width. If a door occurs at the landing, such dimension need not exceed 36 inches. Section R311.7.6. Exception: At the top of an interior flight of stairs, provided a door does not swing over the stairs. ROOFS/DECKS/BALCONIES 8. Specify on the plans the following information for the deck/balcony surfacing materials, per Section R 106.1.1: a) Manufacturer's name and product name/number. b) ICC approval number, or equal. MISCELLANEOUS 9. The plans say "Rebuild wall under deck with 4x4 window"; please clarify this. More comments may be applied once this is clarified. 10. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 11. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ 12. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chris Shaver at EsGil. Thank you.