Loading...
HomeMy WebLinkAbout2656 Gateway Rd; 150; CBC2018-0574; Permit(city of Carlsbad Commercial Permit Print Date: 02/25/2019 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2656 Gateway Rd, 150 BLDG-Commercial 2132622100 $100,704.32 Work Class: Tenant Improvement Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Description: BIRD ROCK COFFEE ROASTERS: 1,556 SF T.I. SHELL TO RESTAURANT Applicant: RONNIE ROLLMAN 4080 Centre St, 203 San Diego, CA 92103-2655 619-358-9220 BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Owner: REGENCY BRESSI LLC 100 Wilshire Blvd, 700 SANTA MONICA, CA 90401 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL FIRE A-2 & A-3 Occupancies -Tl MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -inside CFD SB1473 GREEN BUILDING STATE STANDARDS FEE SEWER BENEFIT AREA FEES -H SEWER CONNECTION FEE (General Capacity alt areas) STRONG MOTION-COMMERCIAL TRAFFIC IMPACT Commercial-Industrial w/in CFD Total Fees: $18,068.07 Total Payments To Date: $18,068.07 Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Contractor: EMPIRE CONSTRUCTION 1570 E Edinger, A SANTA ANA, CA 92705 Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. Jf you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Permit No: CBC2018-0574 Closed -Finaled 10/17/2018 12/03/2018 AKrog 2/25/2019 11:4S:23AM $0.00 $629.55 $440.68 $89.00 $628.00 $55.00 $182.00 $1,832.82 $5.00 $926.22 $825.60 $28.20 $12,426.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov Ccicyof Carlsbad Co Iv\ M.l.R G A. L, RESIDENTIAL BUILDING PERMIT Plan Check Est. Value APPLICATION PC Deposit B-1 {It I Date t')1rcl f<vd. Cu'l'le..t, 'Ro,.srers CiS1fi'3o~:i~ 10/11/18 , I Job Address ::z!li:,? '=zA:f,;:W-y IZJ:, ,+J../.>O Suite: I S"'l:I APN: _________ _ CT/Project#:. _________ Lot#: ____ Fire Sprinklers: lfJ) no Air Conditioning: d'!J)/ no 0 Addition/New: _____ Living SF, ___ Deck SF, ____ Patio SF, ___ Garage SF Is this to create an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __ TL. _, B"Remodel: I ~') v, SF of affected area 1 -,~•~ Yes b o:,cuw,J.Jf Is the area a conversion or change of use ? 0 Pool/Spa: ____ SF Additional Gas or Electrical Features? ------------ □ Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground, Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No Panel Upgrade: Yes/ No D Reroof: ___________________________________ _ D Plumbing/Mechanical/Electrical Only: ________________________ _ D Other:------------------------------------ APPLICANT (PRIMARY) PROPERTY OWNER Name: R r,IJ t:! I ~ iZ, u.-,.n,.,j Name: _5--'-"l{"-'(.!A'-'--'---Jpeope'-"='-'~'-=,:t--'-'-/"'-Y;f'"""-----,---- Address: 4D ho C p..r[/4T S -r. Id--2Q J Address: _"7_,_,_1_,.'1.,_l~L...,~'-"t.JO<./J=--~=---..,C(1a.vr.,,,_,.,K.~1-._--_...D"''f,"'._*...,l/i .... t',ts,__ City: S , D. State: WZip: 9J.-I IJ City: ~$"'-•""'D..._. -------'State:CA Zip: Cf.),/ J,:}. Phone: fr, 19 I l ££-9; ,:JO Phone: fsfj :;-;J ' -l1 s Oo 0 I IL/ Email: r>,ll'!N'le e RA t:fK,,c\fC'M-lffC Tu.e,e, """'-.Email:-----~-------------- DESIGN PROFESSIONAL Name: !(A::r I+ €:R,,t~ ~A,l:,,!stl... Address: l/()90 Cl:fJ[U ~ 1>'7 · .J.L ;)Q:J- City: S • [?, State: Cft-Zip: ~IP J Phone: 1,/f · J 5:8 ' ~,J#-:c, Email: /c5Jl.lC.flt E f?41Cg?-y;c1J17;.c-w,r-tQJ>\ Architect State License: CJ. &st/ 7 CONTRACTOR BUSINESS I Name:@,t,D1tvt=' ~ IY'-tJ Lil tflJ Address: /SJO g, cftJ1fll 68'-/\ V'=" fl..,, ./e A Citv: ~A1VA. State:<-lf Zip: 'z1.: 702 Phone: 7{t./ · 9'.36 · 7?.5 ~ Email: 'Cw,O N@"(.f)l,{PI (1..€-, Co IVf State License: e,~ 'i7~'-'2-Bus. License: >-ffv-f ~ (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's license Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov 8-1 Page 1 of 2 Rev. 06/18 hearby affirm under penalty of perjury one of the following declarations: 0 OPTION A): WORKERS'COMPENSATION DECLARATION: □ I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. □ I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: AC Iii A AA t'"'tZAut:.J _ ,Mt,JllA:,y'lf C~<{ Policy No. Rl(IC C'2Cl"7 S: 82>$ Expiration Date: J-:f I I • e .. □ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any m~-~ner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in ad n the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. CONTRACTOR SIGNATURE: ( OPTION B ): OWNER-BUILDER DEC I hereby affirm that I am exempt from Contractor's License law for the following reason: ~GENT DATE: __.__r 1-M,·::r-:iL.f-l .,_,, s"'--'4 } 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's license Law). □ I am exempt under Section ________ ,Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction ofthe proposed property improvement. □ Yes □ No 2. I {have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction {include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work): OWNER SIGNATURE: __________________ □AGENT DATE: _____ _ CONSTRUCTION LENDING AGENCY. IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: ______________________ Lender's Address: _____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 2S533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). APPLICANT SIGNATURE: _]Z.,__ _ _..___--='--"{? __ -_--________ DATE: __ /_c,,_/~t ~7.,..../_J_r_ 1635 Faraday Ave Carlsbad, CA 92008 B-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 Email: Building@carlsbadca.gov Rev. 06/18 r PERMIT INSPECTION HISTORY REPORT (CBC2018-0574) Permit Typo· BLDG-Commercial Application Date: 10/17/2018 Owner: REGENCY BRESSI LLC Work Class: Tenant Improvement Issue Date: 12/03/2018 Subdivision: Status. Closed -Finaled Expiration Date: 08/12/2019 Address: 2656 Gateway Rd, 150 Carlsbad, CA 92009 IVR Number: 14670 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bo\ting-VVelding {Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 02/13/2019 02/13/2019 BLDG-34 Rough 083806-2019 Passed Andy Krogh Complete Electrical Checklist Item COMMENTS Passed BLOG-Building Deficiency Exterior wa\l electrical boxes (2} OK Yes 02/25/2019 02/25/2019 BLDG-Final 084470-2019 Passed Andy Krogh Complete Inspection Checklist Item COMMENTS Passed BLOG-Building Deficiency Yes BLOG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Fina! Yes February 25, 2019 Page 3of3 ' ' PERMIT INSPECTION HISTORY REPORT (CBC2018-0574) Permit Type: BLDG-Commercial Application Dato: 10/17/2018 Owner: REGENCY BRESSI LLC Work Class: Tenant Improvement Issue Date: 12/03/2018 Subdivision: Status: Closed -Finaled Expiration Date: 08/12/2019 Address: 2656 Gateway Rd, 150 Carlsbad, CA 92009 IVR Number: 14670 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date Checklist Item COMMENTS Passed BLDG-Building Deficiency Walls only, see card. Yes BLOG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topoul Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 01104/2019 01/04/2019 BLOG-17 Interior 080418-2019 Partial Pass Andy Krogh Re inspection Incomplete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Walls only Yes BLOG-85 T-Bar, 080561-2019 Passed Andy Krogh Complete Celling Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLOG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLOG-44 Yes Rough-Ducts-Dampers 01/08/2019 01/08/2019 BLDG-23 080694-2019 Passed Andy Krogh Complete Gas/Test/Repairs 01/23/2019 01/23/2019 BLDG-44 081813-2019 Passed Andy Krogh Complete Rough/OuctsJDampe rs Checklist Item COMMENTS Passed BLOG-Building Deficiency Grease duct pre wrap Yes 01124/2019 01/24/2019 BLDG-44 082106-2019 Passed Andy Krogh Complete Rough/Ducts/Dampe rs Checklist Item COMMENTS Passed BLOG-Building Deficiency Grease duct wrap completed Yes 01/28/2019 0112812019 BLDG-Electric Meter 082298-2019 Passed Andy Krogh Complete Release 02104/2019 02/04/2019 BLDG-85 T-Bar, 082927-2019 Passed Andy Krogh Complete Celling Grids, Overhead February 25, 2019 Page 2 of 3 PERMIT INSPECTION HISTORY REPORT (CBC2018-0574) Permit Type: BLDG-Commercial Application Date: 1011712018 Owner: REGENCY BRESSI LLC Work Class: Tenant Improvement Issue Date: 1210312018 Subdivision: Status: Closed -Finaled Expiration Date: 0811212019 Address: 2656 Gateway Rd, 150 Carlsbad, CA 92009 IVR Number: 14670 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete 12/14/2018 12/14/2018 BLDG-81 078866-2018 Failed Paul Burnette Reinspection Complete Underground Combo(11, 12,21,31) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-11 Foundation-Ftg-Piers No (Rebar) BLDG-12 Steel-Bond Beam No BLDG-21 No U nderg round-Underfloor Plumbing BLDG-31 No Underground-Conduit Wiring 12/17/2018 12/17/2018 BLDG-81 078993-2018 Passed Paul Burnette Complete Underground Combo(11, 12,21,31) Checklist Item COMMENTS Passed BLOG-Building Deficiency No BLDG-11 Foundation-Ftg-Piers No {Rebar) BLOG-12 Steel-Bond Beam No BLDG-21 No Underground-Underfloor Plumbing BLOG-31 No Underground-Conduit Wiring 12/1812018 12118/2018 BLDG-11 079163-2018 Passed Andy Krogh Complete Foundatlon/FtglPler s (Rebar) 12/28/2018 12/2812018 BLDG-16 lnsulatlon 080009-2018 Partial Pass Tim Frazee Reinspection Incomplete Checklist Item COMMENTS Passed BLOG-Building Deficiency Exterior wall insulation and electrical (2) Yes boxes OK BLDG-34 Rough 080008-2018 Partial Pass Tim Frazee Relnspection Incomplete Electrical Checklist Item COMMENTS Passed BLDG-Building Deficiency Exterior wall electrical boxes (2) OK Yes 12/3112018 12/31/2018 BLDG-84 Rough 080121-2018 Passed Michael Collins Complete Combo(14,24,34,44) February 25, 2019 Page 1 of 3 ~~ -~.'-CITY OF CARLSBAD l I INSPECTION RECORD 1 1 I CBC2018-0574 2656 GATEWAY RD . #150 BIRD ROC~COFFEE ROASTERS: 1,556 SF T.L SHELL TO Building Division @ INSPECTION RECORD CARD WITH APPROVED j PLANS MUST BE KEPT ON THE JOB I @ CALL BEFORE 3;00 pm FOR NEXT WORK DAY INSPECTION RESTAURANT 2132622100 12/11/2018 @ FOR BUILDING INSPECTION CALI,: 760-602-2725 OR GO TO: www.carlsbadca.gov/Buildinq AND CLICK ON ""Request Inspection"" CBC2018-057 4 DATE: 12-3-1B If "YES" is checked below that Division's approval is required p_r_i~rto rem,esting a Final Building Inspection. If you have .iny questions please call the applicable divisions .it the phone numbers provided below. After all required approv.ils .ire signed off-fox to 760-602-8560, email to bldginspectio_ns@c.1rlsbad_ca.gov or bring ill a COPY of this cant io: 1635 Far;1day Ave .. Carlsb,ul. IF MARKED "YES", IT IS REQUIRED PRIOR TO ANY CONSTRUCTION STORM WATER PRECON MEETING REQUIRED 760-602-2725 Allow 24 hours IF MARKED "YES", APPROVAL REQUIRED PRIOR TO REQUESTING BUILDING FINAL 760-602-4660 Allow 48 hours Planning/Landscape 760-944-8463 Allow 48 hours 760-438-3891 #34 ROUGH ELECTRIC EV CHARGER #66 MASONRY PRE GROUT #33 LEC SERVICE #32OTEMPORARY □ GROUT □ WALL DRAINS #35 PHOTO VOLTAIC #10 TILH',~NEIS #38 SIGNS #11 POUR STI\\IPS ==:-=--------+-----,1----------j BLDG-FINAL #11 COLUMN FOOTINGS #14 SUBFRAME O FLOOR □ CEILING #1.5 ROOF SHEATHING #13 EXT. SHEAR PANlllS #16 INSUIATI0N #18 EXTERIOR IATH #17 INTERIOR IATH & 11,'IYWALL UNDERGROUND □WASTE □ WIR #24 TOP OUT □ WASTE □ WIR #27 TUB & SHOWER PAN #23 TEST □ GAS PIPING #25 WATER HEATER #28 S0IAR WATER BLDG-FINAL coot:11 POOLS #51 POOL EXCAV STEEL #52 PLUMBING #53 ELEC CONDUIT WIRING #54 EQUIPOTENTIAL BOND #55 PREPIASTER FENCE AIARMS #57 GUNITE BLDG-FINAL REV6/18 coot: 11 MECHANICAL #41 UNDERGROUND DUCTS & PIPING Date FIXED EXTING SYSTEM HYDROSTATIC TEST FIXED EXTINGUISHING SYSTEM FINAL MEDICAL GAS PRESSURETEST MEDICAL GAS FINAL Date Date Date Date COPY OF CARD REQUIRED Inspector Ins ector Ins ector Ins ector SEE BACK FOR SPECIAL NOTES J -Section 5416. Health and Safety Code, State of California (a) There shall be not less than one water closet for each 20 employees or fractional part thereof working at a construction job site. The water closet shall consist of a patented chemical type toilet. (b) For the purpose of this section the term construction site shall mean the location on which actual construction of a building is in progress. (c) A violation of this section shall constitute a misdemeanor. All construction or work for which a permit is required shall be subject to inspection and all such construction or work shall remain accessible and exposed for inspection purposes until approved by the inspector. Work shall not be done beyond the point indicated in each successive inspection without first obtaining the approval of the inspector. CONSTRUCTION HOURS: MONDAY -FRIDAY 7AM -6PM, SATURDAY SAM-6PM NO WORK ON SUNDAYS OR FEDERAL HOLIDAYS DATE ADDITIONAL NOTES F.f". 2- "'"" lt. ALL STAR A/C LIC#943414 CHULA VISTA, CA, 91911 OFFICE # 619-251-1000 ALLSTARAC-CV.NET OUTLET AIR BALANCE REPORT Project1>1cJ R.ocK ~ f'ctcl-cr'::.Job No. _____ Date 2--/,?:./ 11 Location Uslo ~ rd (a ✓l::.~J System K1;.F•I / 11{<.JA-·I Instruments Used A-/ncf BCJW fro) Tested By f!n,,ik P ROOM AREA 1--~-0_P_EN_IN~G~----+-R_E_QU~I_RE_D--+--_P_R~EL_IM_I_NA~R_Y-+ __ FI~NA_L_--" SERVED NO. Model Size Vet CFM Vel CFM -------1-------··-------· ., ·~ -- 2-4q5 s-os L.~------------1-----+-----------+----------___ ,, _______ ,_ -----------------+--------4------------+----------- b 540 5'-{o ____ ____j _ ____j_ __________ ----------+-----···---------·------·--------~-------·------·---- ____________ j_____j____ -----l--.----·-····---+---! I _________ J____---L -----~--~----·· ________ , __ .....\....__, --------· ···-----~--------·-·-·----------- ALL STAR A/C LIC#943414 CHULA VISTA, CA, 91911 OFFICE # 619-251-1000 ALLSTARAC-CV.NET OUTLET AIR BALANCE REPORT Project '61 ro\ Roc\<. ccfke Ccxcicr~ Job No. _____ Date '2-{r?i (11 Location 24§"~ r:516:IJJ/Ay r~ Ctl(/sb.1A System \+P-L. Instruments Used /\±cief How \1oc,J Tested By j-;cru1.Jro r ~--~------------.. ·-------------~------~-------------- ROOM ARIA f----,--O_PE_N_IN-r-G __ -+-_RE_Q-,-UI_R_ED--l-'_'-_-P_R-,--EL_IM_I_NA,-R_Y---+-__ F_IN~A_L_~ SERVED NO, Model Size Vel CFM Vel CFM I iw -----1---1----------1-----·---·---------- ,t _________ ---;-------------- J_ ~ z.co zso lsS" ~ . l-25 ---+-------+----·-··-·-----------1----+-------1--·--·--------.. .,.,. __ , ----------·· ., --·-·-·---- K, khe lf 12 52.--5 550 5?S lJ@.W Sso '611 7-1...S ,___ -----+---+ ---+--+------------------·-··-------·-...... -------------- $" \'L 5z_e:;-\'L<;' ~50 ~ Yer 0 ~--------'------'----+---+------·-----·----------------··----·----- (I) 12-5ZS-SL<; Q:6 ~ Gsc; -----------------· ----·---~--·--------------··----------- 7 l'Z.. 52-5 &so izs (IJll6Jl §ZS f-----4-----------f-----f----+-----------·-·-··"·---e----1------l---+ ---+---- 37D __ lVA> ___ ~--?;l.)o ?£;D ----------------+----e~------··----·----.---------------------- lo i 1----------··--·----+----+----·-----------------------·--····-·-------·-·····-·-··----'---~ P-/llr I \ I 'i.11 (/ 1337 kJ:J qz_c; l'2..s-D I------·--------·-··---------·+------+----------·--------·-. ----.,..~-·---l-~-----1------·----., ·-·-·· " \<l,'1iJ I~ 1000 /7 ,.,,-1170 -~--L----'------------------------------------------ ALL STAR A/C LIC#943414 CHULA VISTA, CA, 91911 OFFICE# 619-251-1000 ALLSTARAC-CV.NET OUTLET AIR BALANCE REPORT Project'f5rJ Pv.cl\ 6fu (~S. Job No. _____ Date _z..-t-/ ),__'3c...t/~l9..___ Location Zft?'S{p Ga~ rJ C4r fs haJ System --'-/-f __ P_·-_/ __ Instruments Used Al nor ./-yy ho,,cA Tested By /Srand41 f ,......-------·-·--·-· OPENING • REQUIRED PRELIMINARY FINAL ROOM AREA SERVED NO. Model Size Vel CFM Vel CFM . --···--· '[)if11(\~ I lo'' 4w 400 41S 4/oS --------·-·-~-- c lo '1 t.l~ 570 $10 47S" --·--·-· 3 ID '1 4too ~00 lJ?:D 4s-o --------___ ,, _____ ·-·---________ _, ____ -------------·---., ... ,., _______ ·------·------------------~-- '--I t'' 200 110 11c; 200 f.-------. -----·-------------------·-----•' ,,, _________ --------~------------·----------···· -------- 5 <i_ II 2CO qo 27-0 -Z.lO --------··--· _., ...... , .. --- h t\\ 2.oo lt; /t::;O I qc:; ---------·-·---------------·-- 7 2oti 41oo (ti)() -sos l-tlo ----·--····· -----.. . ------------·--~ --3 Z.01-~ Llbo 710 l/~0 l-tL\ 0 --··----------. .------·-------------------· -·-------·--· --------------,--. fe~ q (p \\ /00 /2.o loo IOD -·· : \ ----_,, __ ----------·-------··· -------------- E/A I ~-····"·-·-·----·--------------·--·--~---·-------·-· 1-------------·-··~ -·. . .. -·--- re.;A-2------------_,,,, ---·-------·· -----------!-----·-·--------··--------· ····-----·------------------------·-----"··------ R.Jf\ ~ -·--'------·-. ____ ,, ________ -----------------_______ .,_,, ____ -------------- - PRE-FUNCTIONAL CHECKSHEET (PFT) 1 I '11 \ Healthy MAKE-UP AIR UNIT Buildings PROJECT: S,!cl &!S. cd+e"(,' (cre\-c.(s_ TEST DATE: ?-k§~"p J;;ve SYSTEM: ~ ...e UQ t::J.·,r :} LOCATION: EQUIPMENT TAG: ull\-l TESTED BY: '& . N MANUFA1..ruRER fl, '\-'\( !::, MODEL# '.',, "'7 SERIAL# \,,,__,'ii PHASE c...1· ..... ,,, IP VOLTAGE II-". If AMPS 2-. POWER CIRCUIT INSTALLED SATISFACTORY ', ..... OVERLOAD PROTECTION INSTALLED \ :,,. ._ DRAIN LINE & TRAP INSTALLED CORRECTLY ,,,. CONTROLS COMPLETE '\ 1e<-. CORRECT FILTERS INSTALLED \ ·-~ SMOKE DETECTOR INSTALLED & WIRED ,, 'lid. FAN SECTION . FAN PULLEY DIAMETER/ BORE ~,1;;~~-.,f) MOTOR PULLEY DIAMETER / BORE BELT SIZE / NUMBER ,A~t MOTOR HP / PHASE 'IU -l..•, J 72 VOLTAGE -...11,p;- AMPS -~ ~ FAN ROTATION t" /,,,. K ... i ;.-,,, EVAPORATM COOLER PUMP FLOW I J. IL WATER DISTRIBUTION SYSTEM CHECK I f\ .... HEATER SECTION OPERATIONAL VERIFICATION I /VIA- CONTI\OLS FAN CONTROL SEQUENCE VERIFIED \j "'·' SMOKE DETECTOR CIRCUIT SHUT DOWN VERIFIED r A- CALIBRATE THERMOSTAT/ ROOM SENSOR " ,. c UUI..I ,~..,,. r< ,._ PRE-FUNCTIONAL CHECKSHEET (PFT) FAN UNIT PROJECT: SYSTEM: prt::J_,kK c~ r~EsTDATe: -~-_--,..._---------LOCATION: EQUIPMENT TAG: _(~1=.,...,.£;;...--+\--------TESTED BY: MANUFACTURER MODEL#/ SIZE SERIAL# BASE & DUCT CONNECTIONS MAINTENANCE ACCESS SHIPPING BRACKETS REMOVED FLEX CONNECTION/ VIBRATION ISOLATION ELECTRICAL INSTALLED OVERLOAD PROTECTION INSTALLED BELTS & SHEAVES INSTALLED MOTOR HP MOTOR VOLTAGE MOTORAMPS FAN RPM FAN CONTROL SEQUENCE VERIFIED OPERATING W, 1 nOUT VIBRATION 1l'lr \ Healthy Buildings !I!!!! /l A, ..... -,,z_ I 71"l ~ '.& / ~" 0 ... , rr,--l I . " - \JP-~ f-..., l //Ll \It'',,. ,-,i-. ve::, r.; ~· . ·, I I ',,'i ~. " 45: .. '-' '-~ ,,:,,.,_ . 1zx11 -, PRE-FUNCTIONAL CHECKSHEET (PFT) PACKAGED HEAT PUMP PROJECT: SYSTEM: EQUIPMENT TAG: ~l-~R£X:\,<. ~d-fc-e ~TESTDATE: K,_ '!!:!> ,~,f LOCATION: ..u,.u..:;,;_;.;;_;.;;z.~--'.ta.J.U.-----TESTED BY: -~ 1ALDATA MANUFACTURER MODEL# PHASE/ HZ VOLTAGE FLA AMPS POWER CIRCUIT INSTALLED CORRECTLY OVERLOAD PROTECTION INSTALLED VISIBLE DAMAGE VIBRATION ISOLATION INSTALLED CORRECTLY CONDENSATE DRAIN LINE & TRAP INSTALLED CORRECT FILTERS INSTALLED OSA DAMPER INSTALLED SMOKE DETECTOR INSTALLED (IF APPLICABLE) COMPRESSORS MANUFACTURER ~ ...... 11 MODEL# z. r:, £,;I) I<. i;; -"TFO~ PHASE/ HZ VOLTAGE AMPS CONDENSER FAN SECTION MANUFACTURER MODEL# PHASE/ HZ VOLTAGE AMPS EVAPORATOR SECTION SUPPLY FAN/MOTOR BELT TENSION & ALIGNMENT SUPPLY FAN MOTOR HP CONFIRMED SUPPLY FAN VOLTAGE/PHASE/HZ CONFIRMED SUPPLY FAN MOTOR FLA AMPS RATING CONFIRMED CONTROLS FAN CONTROL SEQUENCE VERIFIED COMPRESSOR CONTROL SEQUENCE VERIFIED SMOKE DETECTOR CIRCUIT SHUT DOWN VERIFIED CALIBRATE THERMOSTAT OR ROOM SENSOR NOTES: 1 • •-1 \ ,~,i Healthy Building~ ~FICATIOH (, - !11)1Al'Ar>ni 11..,, L.Af,t.K .., ~,-• .'(i<,1./1""" ..... ...,J 11,.,,,Hc .. I • 1. , \ .... <>. .... , '-In I~ '~·, ' .-c I ,,,.. c.. ' 'C'-'-- CCVllv, I . -• " ,.,..., .... / /!•fl tn, XI ( I'll''( i-e.J ~, 5b4'>Z.:oc on ... ) /~In. '-1Q;7\/ , I ·\l~C:.. II:;.._ \i .... "- "-I.;"<:.: '\l,t"' :!:, ' ,...._ ' .,.._ ' >'CS PRE-FUNCTIONAL CHECKSHEET (PFT) PACKAGED HEAT PUMP PROJECT: SYSTEM: EQUIPMENT TAG: 6, rd Rec.I> uf:(e, fCVE:,\oSTEsT DATE: D,n,a~ rypy>1 u.11iF LoCAnoN, 8£-r TESTED BY: ~ !!!!!!!!!~ MANUFACTURER MODEL# PHASE/HZ VOLTAGE FLA AMPS POWER CIRCUIT INSTALLED CORRECTLY OVERLOAD PROTECTION INSTALLED VISIBLE DAMAGE VIBRATION ISOLATION INSTALLED CORRECTLY CONDENSATE DRAIN LINE & TRAP INSTALLED CORRECT FILTERS INSTALLED OSA DAMPER INSTAil.ED SMOKE DETECTOR INSTALLED (IF APPLICABLE) COMPRESSORS MANUFACTURER MODEL# PHASE/ HZ VOLTAGE AMPS CONDENSER FAN SECTION MANUFACTURER MODEL# PHASE/HZ VOLTAGE AMPS EVAPORATOR SECTION SUPPLY FAN/MOTOR BELT TENSION & ALIGNMENT SUPPLY FAN MOTOR HP CONFIRMED SUPPLY FAN VOLTAGE/PHASE/HZ CONFIRMED SUPPLY FAN MOTOR FLA AMPS RATING CONFIRMED CONTROLS FAN CONTROL SEQUENCE VERIFIED COMPRESSOR CONTROL SEQUENCE VERIFIED SMOKE DETECTOR ORCUIT SHUT DOWN VERIFIED CALIBRATE THERMOSTAT OR ROOM SENSOR NOTES: 1 I ll1 \ Healthy Buildings (' ., r,,.r ., II.-,/ 1H lJ '. /_ .... .. . , ..... I ,1- '\ , .... <:.. ' .,:,, t'""b,. . W) IJ/b. ' Ir><:.._ ' _,...,__ '_,_ '.P<L ' "LJ"Sl'd\\'\'-E-1\'l) 13 ~ r'c ~ ~ <"-(t,l\ 7 . ... ' ' U' .r ,: ... ,,, Co,t-r{e,(" Y~b 73.L b1 ?_ ·~·, I c~ ,, .... , ,,....__ A✓" ' '('.-:--,. ·,!,c, 1 j.,.'" ' ,!,, ""- • :✓c.. ., DATE: 10/24/2018 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2018-0574 ✓• EsG1I A SAFEbuilt'Company SET: I PROJECT ADDRESS:~Gateway Rd. #150 □ APPLICANT /JURIS. PROJECT NAME: Bird Rock Coffe Roasters Tenant Improvement ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted: ~ Telephone#: Date contacted: (b~) Email: Mail Telephone 0 REMARKS: By: Jason Pasiut EsGil Fax In Person Enclosures: 10/18/2018 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 ' c.a,rlsbad CBC2018-0574 10/24/2018 [DO NOT PAY-THIS IS NOT AN INVOICE} VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Jason Pasiut PLAN CHECK#.: CBC2018-0574 DATE: 10/24/2018 BUILDING ADDRESS: 2629 Gateway Rd. #150 BUILDING OCCUPANCY: B BUILDING AREA Valuation Reg. PORTION ( Sq. Ft.) Multiplier Mod. Annlicant orovided valuation Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance ------------~ 1997 UBC Buildin Permit Fee g •i 1997 UBC Plan Check Fee -··-;i Type of Review: 0 Complete Review VALUE D Structural Only D Repetitive Fee ~ Repeats D Other □ Hourly EsGII Fee t-----;IHr.@* Comments: ($) 100,704 100,704 $384.06\ Sheet 1 of 1 Business Name f3 I IZ{) SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE Business Contact OFFICE USE ONLY RECORD ID# __________________ I PLAN CHECK # __________________ I BP DATE State Ct+ State Plan File# Applicant E-mail Telephone# /C:: fZcJLLM l2o I,) I& t!. eAt::tz"-AtC/Jl,U--r,,1,e.1::-·, ,:..-,\ ~/1 j :J~fi · t°r ,-tJ The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for projects within the City of San Diego): Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed project): 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards 3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These. 4. Flammable Solids 8. Unstable Reactives 12. Radioactives PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION (HMD): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 11 0, San Diego, CA 92123. Call (858) 505--6700 prior to the issuance of a building permit. FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: 0 CalARP Exempt I YES ~ (for new construction or remodeling projects) 1. 0 L.J ls your business listed on the reverse side of this form? (check all that apply). 2. 0 [3--Will your business dispose of Hazardous Substances or Medical Waste in any amount? Date Initials 3. 0 [3-"" Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 □ CalARP Required I 4. 5. 6. 7. 8. □ □ □ □ □ pounds and/or 200 cubic feet? B-Will your business store or handle carcinogens/reproductive toxins in any quantity? 0 Will your business use an existing or install an underground storage tank? [3-Will your business store or handle Regulated Substances (CalARP)? G3 Will your business use or install a Hazardous Waste Tank System (Title 22, Article 1 0)? [a Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or reater than 1,320 allons? California's Above round Petroleum Stora e Act). Date Initials 0 CalARP Complete I Date Initials PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCDl: Any YES• answer requires a stamp from APCD 10124 Old Grove Road, San Diego, CA 92131 apcdcomp@sdcounty.ca.gov (858) 586-2650). [*No stamp required ifQ1 Yes and 03 Yes and Q4-Q6 No]. The following questions are intended to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive requirements contact APCD. Residences are typically exempt, except -those with more than one building .. on the property; single buildings with more than four dwelling units; townhomes; condos; mixed-commercial use; deliberate burns; residences fanning part of a larger project. rExcludes garages & small outbuildings.] YES NO 1. 2. 3. 4. 5. 6. □ 13-Will the project disturb 160 square feet or more of existing building materials? □ Gr Will any load supporting structural members be removed? Notification may be required 1 0 working days prior to commencing demolition. (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance Technician? □ □ □ □ □ D (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification may be required 10 working days prior to commencing asbestos removal. B"'" Will the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet (www.sdapcd.org/info/facts/permlts.pdf) for typical equipment requiring an APCD pennit. D (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school bounda Briefly describe business activities: T Name of Owner or Authorized Agent 10 I /'r JI r • Date FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: ________________________________ _ BY· DATE· I I EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMO• APCD COUNTY-HMO APCO COUNTY-HMO APCD "A stamp m this box only exempts businesses from completing or updating a Hazardous Materials Busrness Plan. Other perm1tt1ng requirements may still apply. HM-9171 (08/15) County of San Diego -DEH -Hazardous Materials Division LIST OF BUSINESSES WHICH REQUIRE REVIEW AND APPROVAL FROM THE COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION Check all that apply: AUTOMOTIVE D Battery Manufacturing/Recycling D Boat Yard D Car Wash D Dealership Maintenance/Painting D Machine Shop D Painting D Radiator Shop D Rental Yard Equipment D Repair/Preventive Maintenance D Spray Booth D Transportation Services D Wrecking/Recycling CHEMICAL HANDLING D Agricultural supplier/distributor D Chemical Manufacturer D Chemical Supplier/Distributor D Coatings/Adhesive D Compressed Gas Supplier/Distributor D Dry Cleaning D Fiberglass/Resin Application D Gas Station 0 Industrial Laundry D Laboratory D Laboratory Supplier/Distributor 0 Oil and Fuel Bulk Supply D Pesticide Operator/Distributor CHEMICAL HANDLING D Photographic Processing D Pool Supplies/Maintenance D Printing/Blue Printing D Road Coatings D Swimming Pool D Toxic Gas Handler D Toxic Gas Manufacturer METAL WORKING D Anodizing D Chemical Milling/Etching D Finish-Coating/Painting D Flame Spraying D Foundry D Machine Shop-Drilling/Lathes/Mills D Metal Plating D Metal Prepping/Chemical Coating D Precious Metal Recovery D Sand Blasting/Grinding D Steel Fabricator D Wrought Iron Manufacturing AEROSPACE D Aerospace Industry D Aircraft Maintenance D Aircraft Manufacturing OTHERS AND MISCELLANEOUS □ Asphalt Plant D Biotechnology/Research D Chiropractic Office D Co-Generation Plant D Dental Clinic/Office D Dialysis Center D Emergency Generator D Frozen Food Processing Facility D Hazardous Waste Hauler D Hospital/Convalescent Home D Laboratory/Biological Lab □ Medical Clinic/Office D Nitrous Oxide (NOx) Control System D Pharmaceuticals □ Public Utility D Refrigeration System D Rock Quarry D Ship Repair/Construction D Telecommunications Cell Site D Veterinary Clinic/Hospital D Wood/Furniture Manufacturing/Refinishing ELECTRONICS D Electronic Assembly/Sub-Assembly D Electronic Components Manufacturing D Printed Circuit Board Manufacturing NOTE: THE ABOVE LIST INCLUDES BUSINESSES, WHICH TYPICALLY USE, STORE, HANDLE, AND DISPOSE OF HAZARDOUS SUBSTANCES. ANY BUSINESS NOT INCLUDED ON THIS LIST, WHICH HANDLES, USES OR DISPOSES OF HAZARDOUS SUBSTANCES MAY STILL REQUIRE HAZARDOUS MATERIALS DIVISION (HMO) REVIEW OF BUSINESS PLANS. FOR MORE INFORMATION CALL (858) 505-6880. LIST OF AIR POLLUTION CONTROL DISTRICT PERMIT CATEGORIES Businesses, which include any of the following operations or equipment, will require clearance from the Air Pollution Control District. CHEMICAL 47 -Organic Gas Sterilizers 32 -Acid Chemical Milling 33 -Can & Coil Manufacturing 44 -Evaporators, Dryers & Stills Processing Organic Materials 24 -Dry Chemical Mixing & Detergent Spray Towers 35 -Bulk Dry Chemicals Storage 55 -Chrome Electroplating Tanks COATINGS & ORGANIC SOLVENTS 27 -Coating & Painting 37 -Plasma Arc & Ceramic Deposition Spray Booths 38 -Paint, Stain & Ink Mfg 27 -Printing 27 -Polyester Resin/Fiberglass Operations METALS 18 -Metal Melting Devices 19 -Oil Quenching & Salt Baths 32 -Hot Dip Galvanizing 39 -Precious Metals Refining ORGANIC COMPOUND MARKETING (GASOLINE. ETC) 25 -Gasoline & Alcohol Bulk Plants & Terminals 25 -Intermediate Refuelers 26 -Gasoline & Alcohol Fuel Dispensing COMBUSTION 34 -Piston Internal -Combustion Engines 13 -Boilers & Heaters (1 million BTU/hr or larger) 14-Incinerators & Crematories 15 -Burn Out Ovens 16 -Core Ovens 20 -Gas Turbines, and Turbine Test Cells & Stands 48 -Landfill and/or Digester Gas Flares ELECTRONICS 29 -Automated Soldering 42 -Electronic Component Mfg FOOD 12 -Fish Canneries 12 -Smoke Houses 50 -Coffee Roasters 35 -Bulk Flour & Powered Sugar Storage SOLVENT USE 28 -Vapor & Cold Degreasing 30 -Solvent & Extract Driers 31 -Dry Cleaning ROCK AND MINERAL 04 -Hot Asphalt Batch Plants 05 -Rock Drills 06 -Screening Operations 07 -Sand Rock & Aggregate Plants 08 -Concrete Batch, CTB, Concrete Mixers, Mixers & Silos 1 O -Brick Manufacturing OTHER 01 -Abrasive Blasting Equipment 03 -Asphalt Roofing Kettles & Tankers 46 -Reverse Osmosis Membrane Mfg 51 -Aqueous Waste Neutralization 11 -Tire Buffers 17 -Brake Debonders 23 -Bulk Grain & Dry Chemical Transfer & Storage 45 -Rubber Mixers 21 -Waste Disposal & Reclamation Units 36 -Grinding Booths & Rooms 40 -Asphalt Pavement Heaters 43 -Ceramic Slip Casting 41 -Perlite Processing 40 -Cooling Towers -Registration Only 91 -Fumigation Operations 56 -WWfP (1 million gal/day or larger) & Pump Station NOTE: OTHER EQUIPMENT NOT LISTED HERE THAT IS CAPABLE OF EMITTING AIR CONTAMINANTS MAY REQUIRE AN AIR POLLUTION CONTROL DISTRICT PERMIT. IF THERE ARE ANY QUESTIONS, CONTACT THE AIR POLLUTION CONTROL DISTRICT AT (858) 586-2600. HM-9171 (08/15) County of San Diego -DEH -Hazardous Materials Division ELISE ROTHSCHILD Director Qtountp of $)an :mtego DEPARTMENT OF ENVIRONMENTAL HEALTH FOOD AND HOUSING DIVISION P.O. BOX 129261, SAN DIEGO, CA 92112-9261 Phone: (858) 505-6659 FAX: (858) 505-6824 1 (800) 253-9933 www.sdcdeh,orq AMY HARBERT A~nt Director 12c121 v. Nov 3 '12D Ctry O 20/9 eu OF: PLAN APPROVAL SHEET DBA: BIRD ROCK COFFEE SITE:.28» GATEWAY RD #150, CARLSBAD 92009 BUSINESS OWNER: JEFF TAYLOR I I.. Dt CA R1.. IVG Se DATE: 11/20/18 °1v1s,04 D PC#: DEH2018-FFPP-010336 /v Plans are approved contingent upon the following: I) Department of Environmental Health (DEH) stamped plans shall be maintained at the jobsite and available for review at the time of the inspection. 2) Changes to equipment layout, menu, or application must be submitted for approval. Changes made without approval will make the plan approval null and void. 3) Obtain local Building Department and all applicable agencies permits and approvals PRIOR TO FINAL INSPECTION AND APPROVAL TO OPERATE BY THIS DEPARTMENT. 4) All food and utensil-related equipment shall be certified to applicable sanitation standards by an ANSI accredited testing agency. 5) Upon completion of 50%-80% of construction, call (858) 505-6660 to schedule inspection. In lieu of a J!lumbing inspection by DEH, ensure that the plumbing is constructed to these standards: a. Floor sinks shall be installed ½ exposed and equipped with an appropriate grill cover if no access is provided for cleaning. b. Drain lines shall slope¼" per foot, shall not exceed 15' in length and shall terminate a minimum of I" above the floor sink with a legal air gap or otherwise approved by the enforcing agency. Drain lines shall not intersect walkways or door ways. c. No condensate drainage of any kind can drain to the mop sink. d. 3-compartment sinks, preparation sinks, dump sinks, and any other plumbed equipment must drain indirect to a floor sink. e. Grease traps/interceptors, if required by the local waste water authority must be located outside of the food preparation, food storage, or warewashing areas. f. Floor surfaces must be sloped I :50 to required floor drains. g. Conduits of all types shall be installed within walls as practicable. When otherwise installed, they shall be mounted or enclosed in a chase so as to facilitate cleaning. 6) Owners and/or operators must pass an approved and accredited Food Safety Certification course. Proof of successful completion of this course is to be furnished at the final inspection. 7) All equipment is to be in place and functional. At the time when the final inspection is requested, the facility shall have all utilities operational and all refrigeration shall have an ambient air temperature of38"F or below and shall be equipped with a thermometer accurate to+/-2"F in the warmest section of the unit. 8) Seal all cracks, gaps and crevices in counters, cabinets, around metal flashing, sink backsplashes, around pipes and conduits with silicone sealant. 9) AN AIR BALANCE REPORT IS REQUIRED IF THE FACILITY HAS VENTILATION HOODS. 10) ANY FOOD PROCESSING AREAS MUST BE COMPLETELY ENCLOSED. OPERABLE WINDOWS. MOVEABLE WALL PANELS, GARAGE ROLL-UP DOORS, OR OTHER MEANS OF RENDERING FOOD PROCESSING AREAS NOT FULLY ENCLOSED ARE NOT APPROVED. 11) Be advised, applicable jurisdiction requirements that result in changes to approved plans may require revisions to the Department of Environmental Health plans. Plans reviewed by: Victoria Nguyen, REHS PLEASE EMAIL flueg@sdcounty.ca.gov AT LEAST 10 WORKING DAYS IN ADVANCE TO SCHEDULE INSPECTIONS. A FINAL INSPECTION MUST BE CONDUCTED ANO AN ENVIRONMENTAL HEALTH PERMIT SHALL BE ISSUED PRIOR TO OPENING ANO OPERATING THIS FOOD ESTABLISHMENT. "Environmental and public health through leadership, partnership and science" D HAVE A MIN. I" GAP OR OPEN SPACE 6ETl"EEN THE 6AC.K EDGE OF THE SHELF AND THE MLL •E OF THE SHELF MUST 6E SEALED TO THE MLL Jl'IITH AN APPROVED SEALANT. _ BE INSTALi.Fr, nN MIJr.JltvfllU "'" Ul'-.LJ eA.1..11 ........ -..... • ----• ---·-- Print Date: 02/27/2019 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2656 Gateway Rd, 150 BLDG-Permit Revision 2132622100 $ 100,704.32 Revision Permit Work Class: Commercial Permit Revi~ Lot#: Reference #: Construction Type Bathrooms: Orig. Plan Check#: CBC2018-0574 Plan Check#: Description: BIRD ROCK COFFEE ROASTERS: COMMISSIONG REPORT FORT.I. Applicant: Owner: RONNIE ROLLMAN REGENCY BRESSI LLC 4080 Centre St, 203 San Diego, CA 92103-2655 619-358-9220 FEE BUILDING PLAN CHECK REVISION ADMIN FEE MANUAL BUILDING PLAN CHECK FEE 100 Wilshire Blvd, 700 SANTA MONICA, CA 90401 Total Fees: $ 125.00 Total Payments To Date : $ 125.00 Building Division (city of Carlsbad Permit No: PREV2018-0297 Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Closed -Finaled 11/30/2018 12/11/2018 02/27/2019 AMOUNT $35.00 $90.00 Balance Due: $0.00 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov (cicyof Carlsbad PLAN CHECK REVISION OR DEFERRED SUBMITTAL APP LI CATION B-15 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Original Plan Check Number [DC;;)_ 0 I 8 -0 5 tL/ Plan Revision Number f ( ev ,;JO 18 -(X:::.>9 ef Pro]ect Address d C, Sa G a.1:-e' ' )a id General Scope of R 1 evision/Qeferred Submittal: ___________________ _ /) ~ ',)[2 -;_ /. t...JrrY\ fY\t\ , , di ~O;r UC _ _ CONTACT INFORMATION: Name _____________ Phone ________ Fax~--------- Address ____________________ City _______ Zip ____ _ Email Address _______________________________ _ Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 . Elements revised: D Plans D Calculations D Soils D Energy D Other 2. Describe revisions in detail 4. Does this revision, in any way, alter the exterior of the project? D Yes 5. Does this revision add ANY new floor area(s)? D Yes ~o 6. Does this revision affect any fire related issues? D Yes : ',J3'No 7. Is this a complete set? D Yes ~o A!S'Signatur>-~2 Date 3. List page(s) where each revision is shown yNo 1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: building@carlsbadca.gov www.carlsbadca.gov DATE: 12/10/2018 JURISDICTION: Carlsbad ✓• EsG1I I\ SAFE.built Company PLAN CHECK#.: CBC2018-0574.rev PROJECT ADDRESS: 2& Gateway Rd. #150 SETI □ APPLICANT □ JURIS. PROJECT NAME: Bird Rock Coffee Roasters Commissioning Report Review ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted~/ ~ ~elephone #: Date contacted: -(b Email: Mail Telephone Fax In erson 0 REMARKS: By: Jason Pasiut EsGil Enclosures: 12/3/2018 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad CBC2018-0574.rev 12/10/2018 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK#.: CBC2018-0574.rev PREPARED BY: Jason Pasiut DATE: 12/10/2018 BUILDING ADDRESS: 2629 Gateway Rd. #150 BUILDING OCCUPANCY: B BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Tl revision hourlv review Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code #N/A ---------------------- 1997 UBC Buildin g Permit Fee ... Type of Review: □ Complete Review D Repetitive Fee · · · ;:] Repeats • Based on hourly rate Comments: □ Other D Hourly EsGil Fee Reg. VALUE Mod. D Structural Only 11Hr.@• ~=====$=9=0-=0~0 ($) $90.001 Sheet 1 of 1 OWNER'S PROJECT REQUIREMENTS Bird Rock Bressi Ranch 2629 Gateway Rd, Suite 150 City of Carlsbad Building Division DEC 11 2018 Owner's Project Requirements Bird Rock Bressi '2-~ .:;-e -----2629:Gateway Rd., Suite 150 Carlsbad, CA 92009 Prepared By: Baker Architecture 4080 Centre St., Suite 230 San Diego, CA 92103 PREV2018-0297 2656 GA TEWA y RO BIRD ROCK COFFEE ROASTERS: COMMISSIONG REPORT FOR Tl #150 CBC2018-0574 2132622100 12/11/2018 PREV2018-0297 OWNER'S PROJECT REQUIREMENTS Bird Rock Bressi Ranch 2629 Gateway Rd, Suite 150 Table of Contents Date: 11/26/18 Introduction: ................................................................................................................................................ 3 Project Description and Design Criteria: ...................................................................................................... 3 Project Schedule: ......................................................................................................................................... 3 Project Performance Criteria: ...................................................................................................................... 3 A. Energy Efficiency Goals .................................................................................................................... 3 B. Ventilation Requirements ................................................................................................................ 3 C. Equipment and Systems Expectations ............................................................................................. 4 D. Building Envelope Performance Expectations ................................................................................. 4 E. Sustainability .................................................................................................................................... 4 OWNER'S PROJECT REQUIREMENTS Bird Rock Bressi Ranch 2629 Gateway Rd, Suite 150 Introduction: This Owner's Project Requirements (QPR) document details the functional requirements of the project and expectations of the building use and operation as it relates to systems being commissioned. This document describes the physical and functional building characteristics desired by the owner and establishes performance and acceptance criteria. This QPR will be used to develop the Basis of Design (BOD) during the design process. This OPR cites specific performance and achievement criteria whenever this criterion is known to reflect best current practice and minimum acceptable standards. However, many of the specific baseline benchmarks are not cited herein in anticipation of their development by the design team. Project Description and Design Criteria: • Building Address: 2629 Gateway Rd., Suite 150 • Building Main Primary Proposed Use (e.g. office, warehouse, retail, etc.): M, A-2 • Building Gross Square Feet and Building Area Breakout: 16,650 sf, Project area Suite 150 appx. 1,638 sf. • Building Height (number offloors): 1 story • Occupancy Type: A-2 • Construction Type: Type V-B, Fully Sprinklered • Anticipated Occupancy Schedules for Intended Uses: March 2019 Project Schedule: • Construction Commencement: December 1, 2018 • Construction Completion: March 15, 2019 Project Performance Criteria: A. Energy Efficiency Goals This section establishes goals and targets affecting overall project energy efficiency. The owner's requirements for the following energy efficiency categories are detailed below: 1. Overall energy efficiency goal to meet Title 24 part 6 and CALGreen part 11 requirements for all equipment, lighting and other systems. B. Ventilation Requirements Per minimum requirements set in mechanical code OWNER'S PROJECT REQUIREMENTS Bird Rock Bressi Ranch 2629 Gateway Rd, Suite 150 C. Equipment and Systems Expectations For each system to be commissioned (HVAC and associated controls, lighting and associated controls, domestic hot water and associated controls, irrigation and associated controls, etc.) the following expectations for systems and equipment are set forth below: • The mechanical system is part of with building shell design, unit selection by developer engineer and used by tenant. • A lighting system that offers cost efficient energy savings potential and lighting fixtures and controls shall be selected to meet Title 24 minimum efficiency requirements. D. Building Envelope Performance Expectations For each assembly that contains a special feature, the following is described: • N/A E. Sustainability The below section describes in detail any sustainability goals of the project beyond state and local codes: • Overall Sustainability Goal is to meet Title 24 2016 energy and CALGreen codes. BASIS OF DESIGN Bird Rock Bressi Ranch 2629 Gateway Rd, Suite 150 Basis of Design Bird Rock Bressi 2629 Gateway Rd., Suite 150 Carlsbad, CA 92009 Prepared By: Baker Architecture 4080 Centre St., Suite 230 San Diego, CA 92103 Date: 11/26/18 BASIS OF DESIGN Bird Rock Bressi Ranch 2629 Gateway Rd, Suite 150 Table of Contents Introduction: ................................................................................................................................................ 3 Project Description and Design Criteria: ...................................................................................................... 3 Project Performance Criteria: ...................................................................................................................... 4 A. Heating, Ventilating and Air Conditioning Systems and Controls .................................................... 4 B. Indoor Lighting Systems and Controls ............................................................................................. 4 C. Water Heating Systems and Controls .............................................................................................. 5 D. Irrigation Systems and Controls ....................................................................................................... 5 E. Building Envelope Components ....................................................................................................... 5 Operations & Maintenance: ........................................................................................................................ 5 BASIS OF DESIGN Bird Rock Bressi Ranch 2629 Gateway Rd, Suite 150 Introduction: This Basis of Design (BOD) describes the building systems to be commissioned and captures the project factors that contribute to decisions about envelope, mechanical, lighting, plumbing and irrigation design recommendations. Created as a design criterion, the BOD outlines design specifications and system descriptions for the systems to be commissioned. The BOD documents the concepts on which systems are based, the methodology used to approach the design. The design team developed the BOD to describe how the building systems design meets the Owner's Project Requirements (OPR), and reasoning behind why the systems were selected. The OPR document details the functional requirements of the project and expectations of the building use and operation as it relates to systems being commissioned. The BOD, though most effective when developed early in the project design, can be updated, when necessary, throughout the design process. The specific requirements for mechanical, electrical and plumbing systems are described below and in the design documents which contain criteria pertinent to these systems. The BOD records concepts, design assumptions, important calcu lations, decisions, product selection, rationale, and other applicable regulations, standards and guidelines that the design incorporates to satisfy the OPR. These specifications are based on institutional knowledge including years of designing and operating such facilities but are not intended to supersede state and local codes. The project will comply with industry standards and requirements for general construction, energy use, accessibility and fire life safety. In addition, the project shall comply with relevant applicable local codes and sustainability initiatives, if applicable. Project Description and Design Criteria: • Building Address: 2629 Gateway Rd, Suite 150 Carlsbad, CA 92009 • Building Main Primary Proposed Use: Retail/ Restaurant (Groups A-2 & M) • Building Gross Square Feet and Building Area Breakout: 16,650 sf, Project area Suite 150 appx. 1,638 sf. • Occupancy Type: A-2 • Construction Type: V-B, Fully Sprinklered • Climatic Design Conditions: Climate Zone 7 • Applicable Codes and Standards: Type: Name of Code/ Standard Reason Used CA 2016 California Building Code Required CA 2016 California Plumbing Code Required CA 2016 California Mechanical Code Required CA CCR Title 24 -Building Energy Standards Required Local 2016 California Fire Code Required California Code of Regulations Title-24 Required for Accessibility National NFPA National Electrical Code Required NFPA 90A Required, AC Systems BASIS OF DESIGN Bird Rock Bressi Ranch 2629 Gateway Rd, Suite 150 Type: Name of Code/ Standard Reason Used NFPA 13 Required, Sprinkler Systems Professional ASH RAE Standard 15 -2007 Filter Efficiency and Arrestance ASH RAE Standard 52.1 -1992 Mechanical Refrigeration Safety ASH RAE Standard 55 -2010 Thermal Comfort ASH RAE Standard 62 -2010 Ventilation SMACNA Duct Construction Standards -1997 Industry Standard Project Performance Crit eria: A. Heating, Ventilating and Air Conditioning Systems and Controls HVAC systems will be designed to provide a comfortable and controllable thermal environment while maximizing the clear floor to floor heights of the newly constructed spaces. There are many important objectives in the design of a building air conditioning system t o achieve real comfort conditions for the occupants. Provide narrative description of system: • The mechanical system is part of with building shell design, unit selection by developer engineer and used by tenant. B. Indoor Lighting Systems and Controls The light levels meet or exceed the desired levels by the end user and Illuminat ing Engineers recommendations. Provide narrative description of system: • The selected lighting systems offer cost efficient energy savings potential and lighting fixtures and/or controls shall be selected to meet Title 24 minimum efficiency requirements. General: • type of fixtures -down light, pendant, 2x4 recessed, Monopoint, Vanity • lamps -LED • ballasts -Dimmable • controls -Dimmers, Occupancy & Daylight Sensors, Time Clock • Provide reason for system selection and why chosen system is better than alternatives considering issues such as: • Integration with Daylighting • Ease of Control • Provide design criteria for each type of space including the following: • Area Category Method Table 140.6-C • CCR Title 24 Building Energy Standards • Provide lighting power design targets for each type of space BASIS OF DESIGN Bird Rock Bressi Ranch 2629 Gateway Rd, Suite 150 • Area Category Method Table 140.6-C • Describe how system meets the QPR. The system meets QPR by cost efficiency and meeting minimum Energy Design C. Water Heating Systems and Controls Provide narrative description of: • Tank -Gas • Electronic, Microprocessor • Kitchen • Polymer Composite Thermowell, Ultra Low NOx • Bradford White • Ultra Low NOx • 60 psi • Describe reason for system selection and why chosen system is better than alternatives considering issues such as: • Performance • Efficiency • Reliability • Space Constraints • Health Department Requirements • Describe How System Meets The QPR • The system meets QPR by cost efficiency and meeting minimum Energy Design D. Irrigation Systems and Controls Provide narrative description of: • N/A E. Building Envelope Components Provide narrative description of system: • N/A Operations & Maintenance: The staff that will be operating the building after completion have experience with building O&M requirements. The contractor is to provide training on all building systems. The O&M staff will have to be trained to operate all systems with which they are not familiar and/or enter into maintenance agreements for same. The O&M staff will also be trained with the system to monitor the buildings' systems and respond to notifications that indicate operating parameters if they move outside of the design criteria.