HomeMy WebLinkAbout2657 CAZADERO DR; ; CB101315; Permit07-15-2010
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Electrical Permit Permit No: CB101315
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Reference #:
PC#:
Project Title:
2657 CAZADERO DR CBAD
ELEC
2153003000
KERN RES- TO INCLUDE 2659
Lot#:
NEW 40Q AMP 2-METER PANEL 100 AMP TO 2657 200 AMP
Status: ISSUED
Applied: 07/15/2010
Entered By: LSM
Plan Approved: 07/15/2010
Issued: 07/15/2010
Inspect Area:
Applicant:
KERN FAMILY TRUST 04-20-04
2659 CAZADERO DR
CARLSBAD CA 92009
7609189115
Owner:
KERN FAMILY TRUST 04-20-04
2659 CAZADERO DR
CARLSBAD CA 92009
Electric Issue Fee
Single Phase per AMP
Three Phase per AMP
Three Phase 480 Per AMP
Remodel/Alteration per AMP
Remodel Fee
Temporary Service Fee
Test Meter Fee
Other Electrical Fees
Additional Fees
0
0
0
300
$10.00
$0,00
$0.00
$0.00
$75.00
$0.00
$0.00
$0.00
$27.00
$0.00
TOTAL PERMIT FEES $112.00
Total Fees:$112.00 Total Payments To Date:$112.00 Balance Due;$0.00
Inspector:
FINAL APPROVAL
Date: _f±ZJL Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired.
A'p. Building Permit Application
""'— 1635 Faraday Ave., tlSriihad, CA 92008
CITY OF 760-602-2717 / 2718/ 2719
/""Am CD A l~\ Fax:760-602-8558
V _ f\ f\ § ^ Q/*\ tJ www.carlsbadca.gov
Plan Check NoCB 10 (3'
Est. Value
Plan Ck. Deposit
Date «o
JOB ADDRESS SUITE#/SPACE#/UNIT#
CT/PROJECT## BATHROOMS
2V
TENANT BUSINESS NAME CONSTR.TYPE OCC. GROUP
DESCRIPTION OF WORK: /nc/utfe Square Feet of Affected Areafs)
t*J // oo rz>
CONTACT NAME (H Different Fom Applicant)
CITY
PHONE FAX PHONE
EMAIL EMAIL
PROPERTY OWNER NAME CONTRACTOR BUS. NAME
ADDRESS ADDRESS
CITY STATE ZIP CITY STATE ZIP
PHONE FAX PHONE FAX
EMAIL EMAIL
ARCH/DESIGNER NAME & ADDRESS STATE LIC. #STATE LIC.#CLASS CITY BUS. LIC.#
civil penalty of not more than five hundred dollars ($500)).
Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations:
O I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this perm it is issued.
G I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co. ; Policy No. Expiration Date ;
This section need not be completed if the permit is for one hundred dollars ($100) or less.
G Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
CONTRACTOR SIGNATURE OAGENT DATE
/ hereby affirm that I am exempt from Contactor's License Law for the following reason:
O I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
salertf, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
1, as owner of the properly, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law).
I am exempt under Section Business and Professions Code for this reason:
D No1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement, O Yes
2.1 (have / have not) signed an application for a building permit for the proposed work.
3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number):
4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / sontrattora1 license number);
5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work):
_/7
> PROPERTY OWNER SIGNATURE DATE
N B U i5
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or ri sk management and prevention program under Sections 25505,25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? DYes d No
Is he applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? O Yes D No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? a Yes a No
IF ANY OF THE ANSWERS ARE YES, /
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name Lender's Address
I certify that I have read the application and state that the above information is correct and that the Information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon Die above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the BuildingOffcial under the provisions of this Code shall expire by limitation and become null and void if the buildiig or work authorized by such permit is not commenced within
180 days from the date of such permit or if Sie,^^
.^APPLICANT'S SIGNATURE // J/I/AM//Y £s r^/^A DATE 1
CARLSBAD
CITY OF
STORM WATER
COMPLIANCE
ASSESSMENT
B-24
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
am applying to the City of Carlsbad for the following type(s) of construction permit:
Q Building Permit a Right-of-Way Permit
D My project is categorically EXEMPT from
the requirement to prepare a storm water
pollution prevention plan (SWPPP) because it
only requires issuance of one or more of the
following permit types:
Electrical
Fire Additional
Fire Alarm
Fixed Systems
Mechanical
Mobile Home
Plumbing
Patio/Deck
Re-Roofing
Sign
Spa-Factory
Sprinkler
Water Discharge
Project Storm Water Threat Assessment Criteria*
Wo Threat Assessment Criteria
Q My project qualifies as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan (SWPPP) because
it meets the "no threat" assessment criteria on the City's Project Threat Assessment Worksheet for Determination of Construction SWPPP Tier
Level. My project does not meet any of the High, Moderate or Low Threat criteria described below.
Tierl - Low Threat Assessment Criteria
G My project does not meet any of the Significant or Moderate Threat criteria, is not an exempt permit type (See list above) and the project
meets one or more of the following criteria:
• Results in some soil disturbance; and/or
• Includes outdoor construction activities (such as saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling).
Tier 2 • Moderate Threat Assessment Criteria
Q My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria:
• Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code); or,
• Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement
removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria:
• Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or
• Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or
• Disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse, and/or
• Construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30).
TierS - Significant Threat Assessment Criteria
Q My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any
associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or
Q My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any
associated construction staging, equipment storage, refueling and maintenance areas: or,
U My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant
potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s).
/ certify to the best of my knowledge that the above
checked statements are true and correct. I understand
and acknowledge that even though this project does
not require preparation of a construction SWPP, / must
sf/7/ adhere to, and at all times during construction
activities for the permit type(s) check above comply
with the storm water best management practices
pursuant to Title 15 of the Carlsbad Municipal Code
and to City Standards.
'The City Engineer may authorize minor variances from the Storm
Water Threat Assessment Criteria in special circumstances where it
can be shown that a lesser or higher Construction SWPPP Tier Level is
warranted.
Project Address:Assessor Parcel No.
jwner/Qwner's Authorized Agent Name:
Owner/Owner's Authorized Agent Signature:
City Concurrence:
Q YES UNO
By:Date:
Title:
Date:
Project ID:
B-24 Page 1 of 1 Rev.03/09
City of Carlsbad Bldg Inspection Request
For: 09/13/2010
Permit* CB101315
Title: KERN RES- TO INCLUDE 2659
Inspector Assignment: RB
Description: NEW 400 AMP 2-METER PANEL 100 AMP TO 2657 200
AMP TO 2659 REPLACING EXISTING 100 AMP NEW GAS
i IMC' -rf\ nafn i in/^r» A rNrrr% -m A A i tn
Type: ELEC Sub Type:
Job Address: 2657 CAZADERO DR
Suite: Lot: 0
Location:
OWNER KERN FAMILY TRUST 04-20-04
Owner:
Remarks:
Phone:
Inspector:
Total Time:
CD Description
39 Final Electrical
Act Comments
Requested By: KERN
Entered By: CHRISTINE
'* *
Comments/Notices/Holds
Associated PCRs/CVs/SWPPPs Original PC#
Inspection History
Date Description Act Insp Comments
08/04/2010 33 Service Change/Upgrade PA RB OK FOR METER RELEASE
07/16/2010 21 Underground/Under Floor AP RB UNDRG GAS LINE
07/16/2010 23 Gas/Test/Repairs AP RB GAS METER RELEASE
i \ f .
City of Carlsbad Bldg Inspection Request
For: 07/16/2010
Permit* CB101315
Title: KERN RES- TO INCLUDE 2659
Inspector Assignment:
Description. NEW 400 AMP 2-METER PANEL 100 AMP TO 2657 200
AMP TO 2659 REPLACING EXISTING 100 AMP NEW GAS
rr\ * * itn
Sub Type:
2657 CAZADERO DR
Lot: 0
Type: ELEC
Job Address:
Suite:
Location:
OWNER KERN FAMILY TRUST 04-20-04
Owner:
Remarks:
Phone: 7609189115
Inspector:
Total Time:
CD Description
23 Gas/Test/Repairs
Act Comments
Requested By: AL
Entered By: CHRISTINE
.
Comments/Notices/Holds
Associated PCRs/CVs/SWPPPs Original PC#
Inspection History
Date Description Act Insp Comments
^ CITY OF CARLSBAD
ELECTRIC AND GAS METER CLEARANCE
INTER-DEPARTMENT
ADDRESS:
S.E.O. Service Equipment Only YES
NO
Reason, If Denied: : :
ELECTRIC METER:
COMMERCIAL
RESIDENCE
NEW SERVICE YES
RELOCATE NO
T.S.P.B.
i__ TEMP. P/P
UP-GRADE
TEST METER .
IRR. PEDESTAL
GAS METER:
COMMERCIAL _/ YES
RESIDENCE «/ • NO
TEST METER
__
Building Intpector Signature Date Time
Called In By Date Time
Called In To
00
Rea
CL
55
I"00
^;
*SubtoUlo'bo8
11! T1IIIBIS
</J : <X>CD i fl>
oi o'O : 0>
§1?
P
C0!
Es •
>; ui
Tli
11<*! e>
wa : ..r
l'SH°ial
tn
^G
seeDisposals @ 800 VAMicrowaves @ 1,000 VAed appDishwasG
ce loadsVA88!:
! ooitoi
|8|8|
i^^l
E53
Ul Ul
Ul LaSGeneral Lighting loadselling @3VA/sfall Appliance @ 1 300dry load @ 1 300 VAf—i Ji.! O\
t—>i ^i 4^j
'Uli'Uli'bo!
8! 8! 8
W
a,
a
3*3
11
t»
Ul OO i
ts> 'o
§
00
8
•>i Uli Uli wi i !Oi
I'OO:
Kern - Electric Service up grade with 400 amp service, 6/25/2010
400 amp panel
2 meters » 100 amp Breaker to serve 2657
» 200 amp Breaker to serve 2659
New 200 amp sub-panel 40 slots
220 Circuits
1-2 Dryer Plug converted to serve existing A/C
3-4 Existing A/C converted to serve Suite A/C unit
5-6 Future A/C serving Office
7-8 Elevator
9-10 Spare
11-12 Spare
110 Circuits
13 Microwave
14 Microwave
15 Refrigerator Freezer
16 Refrigerator Freezer
17 Dishwasher
18 Ranges [2] ,Gas
19 FAU Existing
20 FAU Suite
21 Future FAU Office and family room]
22 Fan - Kitchen Hood
23 Fan Master Bath
24 Fan Added Bath
25 Kitchen Plug Circuits
26 Kitchen Plug Circuits
27 Dishwasher
28 Disposal
29 Outlets
30 Outlets
31 Outlets
32 Lights
33 Lights
34 Lights
35 Spare
36 Spare
37 Spare
38 Spare
39 Spare
40 Spare
Kern Job 2659 Cazadero Dr Carlsbad CA 92009 8-Jul-10
Existing Service to House from Meter is 1" Dia.
Existing Demand
40 Gal WH 50,000 BTU
FAU 40,000 BTU
Dryer 35,000 BTU
Range 35,000 BTU
BBQ 50,000 BTU
Log Lighter 25,000 BTU
Sub-Total 235,000
Addition
FAU 40,000 BTU
Dryer 35,000 BTU
Range 35,000 BTU
Future
FAU
WH increase to 60gal
Existing WH Spec
Existing FAU Spec
Existing Dryer Spec
New Kitchaid Spec
Allowance
Allowance
Assumed same size unit
Assumed same size unit
New Kitchaid Spec
345,000 Total BTU's required
60,000 BTU
34,000 BTU
439,000 Total BTU's required w/future additions
Rick says supply to house has to be increased to 1-1/4".