Loading...
HomeMy WebLinkAbout2659 CAZADERO DR; ; CB130232; Permit02-27-2013 Job Address' Permit Type Parcel No Valuation Occupancy Group Project Title City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Cogeneration Permit Permit No:CBi30232 Building Inspection Request Line (760) 602-2725 2659 CAZADERO DR CBAD COGEN Sub Type PHOTO 2153003000 Lot#. 0 $12,800 00 Constuction Type NEW Reference # KERN RES -32 MODULES PHOTOVOLTAIC ROOF-MODULES Status' ISSUED Applied 01/28/2013 Entered By SKS Plan Approved 02/27/2013 Issued 02/27/2013 Inspect Area PY Plan Check # Applicant SOLARCITY Owner KERN FAMILY TRUST 04-20-04 3055 CLEARVIEW WY SAN MATEO CA 94402 650-638-1028 2659 CAZADERO DR CARLSBAD CA 92009 Building Pernnit $156 27 • PLUMBING TOTAL $0 00 Add'l Building Permit Fee $0 00 ELECTRICAL TOTAL $0 00 Plan Check $109 39 MECHANICAL TOTAL $0 00 Add'l Plan Check Fee $0 00 Additional Fees $0 00 Plan Check Discount Strong Motion Fee Green Bldg Stands (SB1473) Fee $0 00 $1 28 $1 00 TOTAL PERMIT FEES $267 94 Total Fees $267 94 Total Payments To Date' $267 94 Balance Due: $0.00 Inspector FINAL APPROVAL c/<r/to/3 Date Clearance NOTICE Please take NDTICE/hat approval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously othenwise expired CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717 / 2718 / 2719 Fax: 760-602-8558 www.carlsbadca.gov Plan Cheek No. Ob I^^3^ Est. Value \ 7^ ^fOQ Plan Ck. Deposit | QCj SU1TE#/SPACE#/UNIT# APN CT/PROJECT # LOT# PHASE# # OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR TYPE oca GROUP SWPP DESCRIPTION OF WORK: Include Square Feet of Affected Area(a) EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YES • # NOD AIR CONDITIONING YES n NO • FIRE SPRINKLERS ' YES • NO • CONTACT NAME W Different Fom Applicant) APPUCANT NAME ADDRESS ADDRESS CITY v? \ ' ' ? STATE PHONE n _ CA ZIP PHONE FAX EMAIL PROPERTY OWNER NAME CONTRACTOR BUS. NAME ADDRESS CITY ADDRESS PHONE STATE CITY • 1 STATE ZIP PHOIMh • FAX EMAIL EMAIL ARCH/DESIGNER NAME & ADDRESS STATE UC # C-i.<-9 r-> l-T-^ Ll . 'CITYBUS UC.# (Sec 70315 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, pnor to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). Workers' Compensation Declaration / hereby affirm underpenalty of perjury one ofthe following declarations O I have and will maintain a certificate of consent to self-insure for workeis' compensation as provided by Section 3700 of the Labor Code, for the performance of the work fbr which this pemiit is issued ^/tfThave and will maintain workers' compensation, as required by Section 3700 of the Labor Code, fbr the performance of the work for which this pemiit is i^ued My woikera' compensaton insuranpe c^or and policy numberare InsuranceCo PjJfi^ In y4-Vv^U2^~. f <1 Policy No \AJC ^1 (r ^ ^ W Expiration Date / \ / i 5 This section need not be completed if the penrat is for one hundred dollars ($100) or less O Certificate of Exemption: I certify that in the perfomance of the work for which this permit is issued, 1 shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING. Failure to secure worjters' compensation coverage is unlawful, arul shall subjectnn employer to cnminal penalties and civil fines up to one hundred thousand dollars (&100,000), in i%vided/or in S^ctioi) 3706 of the i^^r code, interest and attorney's fees. addition to the cost of compensation, dam^agej •AGENT DATE I hereby affinn that I am exempt from Contractors Micense Law for the following reason • I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Busmess and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such worit himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) n i, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's Ucense Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractors License Law) • I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and matenals for construction of the proposed property improvement C! Yes • No 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number)' 4 I plan to provide portions of the work, but i have hired the following person to coordinate, supen/ise and provide the ma)or work (include name / address / pnone / contractors' license number)- 5 i will provide some of the wori(, but I have contracted (hired) the Ibllowing persons to provide the work indicated (include name / address / phone / type of work) jg^PROPERTY OWNER SIGNATURE •AGENT DATE to submit a business plan^cutely hazardous matenals registration fomn or nsk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Acf OYes 0^0 ^ is the applicant or future buildmg occupant required to obtain a pemiit from the air polluton control distnct or air quality management distncf O Yes ^fva Is the facility to be constructed within 1,000 feet of the outer boundary ot a school site'' • Yes • No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a constnjction lending agency for the performance of the work this permit is issued {Sec 3097 (i) Civil Code) Lender's tNlame Lender's Address I certily that I have read the applicaton and state thatthe above infoimation is conectand thatthe infomiaton on Itie plans is accurate I agree to comply with all City onlinances and State laws leiatngto Iwildingcanstnictofl i hereby aulhonze representative of ihe City of Carlsbad to enter upon Ihe atrave mentioned pnjperty for mspecton puiposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD A(3AINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CfTY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT < OSHA An OSHA peirrit is required for excavatons over 5'0' deep and demolition or construction of structures over 3 stones n height EXPIRATION Eveiy penrat issued by the Building Official under the provisions of this Code shall expire by limitaton and becoine null and void if Ihe building or woi1< authonzed by such pennit is not commenced withm 180 days ttom Ihe date of such penmt or rf the bu|le«Tg or work authonzed by such pennit E suspendef^r abandoned at any tme after Ihe work s commenced for a penod of 180 days (Section 106 4 4 Uniform BuiUing Code) >€rAPPLICANT'S SIGNATURE DATE Inspection List Permit*: CB130232 Type: COGEN PHOTO Date Inspection Item 05/29/2013 35 Photo Voltaic (PV) 05/29/2013 35 Photo Voltaic (PV) 05/29/2013 39 Final Electncal 05/29/2013 39 Final Electncal Inspector Act Rl PY AP Rl PY AP KERN RES -32 MODULES PHOTOVOLTAIC ROOF-MODULES Comments Friday, May 31, 2013 Page 1 of 1 EsGil Corporation In (Partnership with government for (BuiCding Safety DATE: 02/07/2013 OAEPLICANT JURISDICTION: City of Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 13-0232 SET I PROJECT ADDRESS: 2659 Cazadero Dr. PROJECT NAME: Kern Roof Mounted 6 kW PV System XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: 1X1 EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person • REMARKS: By: Aaron Goodman Enclosures: EsGil Corporation • GA • EJ • PC 01/31/2013 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 13-0232 02/07/2013 [DO NOT PAY- THIS IS NOTAN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 13-0232 PREPARED BY: Aaron Goodman DATE: 02/07/2013 BUILDING ADDRESS: 2659 Cazadero Dr. Set I BUILDING OCCUPANCY: R-3 TYPE OF CONSTRUCTION: V-B BUILDING PORTION AREA (Sq. Ft) Valuation Multiplier Reg. Mod. VALUE ($) PV System Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review. I I Repetitive Fee ^ Repeats • Complete Review • Other Q-j Hourly EsGil Fee $107.50 • Structural Only $86 00 Hr. @ $86.00 Based on hourly rate Comments: Sheet 1 of 1 macvalue doc + 05-29-2013 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No:PCR13060 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # PC# Project Title 2659 CAZADERO DR CBAD PCR 2153003000 Lot# 0 $0 00 Construction Type NEW CB130232 KERN RES - CHANGED PV INVERTER QTY FROM 1 TO 2 // CHANGE TYPE TO SOLAR EDGE 3800 Status Applied Entered By Plan Approved Issued Inspect Area ISSUED 04/30/2013 SKS 05/29/2013 05/29/2013 Applicant SOLAR CITY/ALEXANDRA SINK/LAURA KLEMENTS Owner KERN FAMILY TRUST 04-20-04 5183 MERCURY PT SAN DIEGO CA 92111 619-857-9209 2659 CAZADERO DR CARLSBAD CA 92009 Plan Check Revision Fee Fire Expedited Plan Review Additional Fees $107 50 $0 00 $0 00 Total Fees $107 50 Total Payments To Date $107 50 Balance Due: $0.00 Inspector FINALAPPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or sen/ice fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previouslv otherwise expired ^CITY OF CARLSBAD PLAN CHECK REVISION APPLICATION B-15 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Plan Check Revision No. .Original Plan Check No. Date Project Address Contact Email Contact Address. CitySar? DiVffi Zip General Scope of \X/ork'dmVSl<=ler 4^^^ /^U^^nhkl^ CMriyia^ Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 • Elements revised: ^ Plans • Calculations • Soils • Energy • Other 2. Describe revisions in detail 3. List page(s) where each revision is shown 4. List revised sheets that replace existing sheets {3 • Does this revision, in any way, alter the exterior of the project? j^Yes 6. Does this revision add ANY new floor area(s)? • Yes ^ No T. Does this revision affect any fire related issues? Q Yes ^No 8. Is this a complete set? ^ Yes • No ^Signature '^^/jl/m^^l^^^'^^^^ • No 1635 Faraday Avenue, Carlsbad, CA 92008 Eh' 760-602- 2719 Fax: 760-602-8558 Email: building@carlsbadca.gov www.carlsbadca.gov EsGil Corporation In Partnership with government for (BuiCding Safety DATE: 05/22/13 • APPLICANT a^jURis. JURISDICTION: Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 13-0232aBPCR 13-60 II SET II PROJECT ADDRESS' 2629 Cazadero Dr. PROJECT NAME: Kern 7600 Watt Solar Photovoltaic System XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: iXl Esgil Corporation staff did not advise the applicant that the plan check has been completed. I I Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Alexandra Sink Telephone #: 619-857-9209 Date contacted. (by. ) Fax #: IWail Telephone Fax In Person E-mail: asink@solarcity.com • REMARKS: By: John Le Vey Enclosures: EsGil Corporation • GA • EJ • PC 05/17/13 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In (Partnership with government for (BuiCding Safety DATE: 05/09/13 • APPLICANT ^ JURIS JURISDICTION: Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 13-02328BPCR13-60 SET I PROJECT ADDRESS: 2629 Cazadero Dr. PROJECT NAME: Kern 7600 Watt Solar Photovoltaic System I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: I I Esgil Corporation staff did not advise the applicant that the plan check has been completed. IXI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Alexandra Sink Telephone #: 619-857-9209 Date contacted: ^110 (by: Fax #: v^ail "telephone Fax In Person E-mail: asink@solarcity.com • REMARKS: By: John Le Vey Enclosures: EsGil Corporation • GA • EJ • PG 04/30/13 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 13-02328sPCR13-60 05/09/13 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: 13-0232a5PCR13- 60 PROJECT ADDRESS: 2629 Cazadero Dr. DATE PLAN RECEIVED BY DATE REVIEW COMPLETED: ESGIL CORPORATION- 04/30/13 05/09/13 REVIEWED BY: John Le Vey FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections and submit two new complete sets of prints to: ESGIL CORPORATION. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this lisf? • Yes • No Carlsbad 13-0232&PCR13-60 05/09/13 JURISDICTION. Carlsbad 60 PREPARED BY: John Le Vey BUILDING ADDRESS: 2629 Cazadero Dr. [DO NOT PAY- THIS IS NOTAN INVOICE] VALUATION AND PLAN CHECK FEE PLAN CHECK NO.: 13-023286PCR13- DATE: 05/09/13 BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING PORTION AREA (Sq. FL) Valuation Multiplier Reg. Mod. VALUE ($) PV system Air Conditioning Fire Spnnklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance $107.50 Type of Review I I Repetitive Fee Repeats • Complete Review • Other •—Uour^ EsGf'l Fee • Structural Only 1 $86 00 Hr. @ $86.00 Based on hourly rate Carlsbad 13-02328BPCR13-60 05/09/13 ELECTRICAL and ENERGY COMMENTS PLAN REVIEWER: John Le Vey ELECTRICAL (2010 CALIFORNIA ELECTRICAL CODE) 1 The Solaredge inverters you are proposing to use are limited to 500 volts ,with 16 modules at 37.30 VOC the system is 596.8 volts, which is still below the max of 600 , except when you add the Voltage correction factor of 1.02 per table 690.7 CEC , which in turn brings the system to approx 608-609Volts. Please revise the system to comply with the max. of 600 volts /or 500 volts per the inverter. Note: If you have any questions regarding this Electrical and Energy plan review list please contact John Le Vey at (858) 560-1468 x119. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans.