Loading...
HomeMy WebLinkAbout2659 GATEWAY RD; BLDG D; CB072912; Permit05-19-2008 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB072912 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2659 GATEWAY RD CBAD COMMIND Sub Type COMM 2131910800 Lot# 0 $524,272 50 Construction Type VN Reference # CT060024 BRESSIVILL-BLDG D 8,630 SF RETAIL BLDG Status Applied Applicant MIKE MERRILL 1717KETTNERBLVD STE 100 SAN DIEGO 92101 619-814-0080 Plan Approved Issued Inspect Area Plan Check* Owner LNR BRESSI COMMERCIAL INC C/O LENNAR PARTNERS 4350 VON KARMAN AVE #200 NEWPORT BEACH CA 92660 ISSUED 11/19/2007 Entered By 04/23/2008 04/23/2008 JMA Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $2,011 50 Meter Size $0 00 Add'l Reel Water Con Fee $1,30748 Meter Fee ($433 00) SDCWA Fee $0 00 CFD Payoff Fee $11010 PFF (3105540) $3,452 00 PFF (4305540) $0 00 License Tax (3104193) $0 00 License Tax (4304193) $000 Traffic Impact Fee (3105541) $000 Traffic Impact Fee (4305541) $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $7,702 00 Master Drainage Fee D1 Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees HMP Fee TOTAL PERMIT FEES $000 $225 00 $7,18800 $22,881 58 $9,541 76 $000 $000 $000 $18,12000 $000 $11900 $91000 $11300 $000 $9,484 20 $000 $000 $000 $82,732 62 Total Fees $82,732 62 Total Payments To Date $82,732 62 Balance Due $000 Inspector FINAL A Date _ IVAL Clearance NOTICE Please take NOTICE th# approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired City of Carlsbad Final Building Inspection Hj^jgj^gjl Depf Building Engineering Plan Check # Permit # Project Name Address Contact Person Sewer Dist Inspected • By _>\ Inspected By Inspected By PC 07-64 CB072912 BRESSIVILL-BLDG RETAIL BLDG 2659 GATEWAY RD DAVID OBRIEN CA .uu ' Planning CMWD D 8.630SF Phone 7604451279 Water Dist CA Date Inspected C'C^'O Date Inspected Date Inspected StLite Fire Date Permit Type Subtype Lot 0 '1 Approved A. Approved Approved 02/11/2009 COMMIND COMM Disapproved Disapproved Disapproved Comments City of Carlsbad Final Building Inspection Dept Building Engineering Planning CMWD St Lite Plan Check # Permit # Project Name Address Contact Person Sewer Dist Inspected > Bv 6= Inspected Bv Inspected Bv Comments PC 07-64 CB072912 BRESSIVILL-BLDG RETAIL BLDG 2659 GATEWAY RD DAVID OBRIEN CA *-g / D 8,630 SF Phone 7604451279 Water Dist CA Date I f Inspected H*t j^i Date Inspected Date Inspected Date Permit Type Sub Type Lot 0 Approved U^ Approved Approved 02/11/2009 COMMIND COMM Disapproved Disapproved Disapproved City of Carlsbad Bldg Inspection Request For 02/11/2009 Permit* CB072912 Title BRESSI VILL -BLDG D 8,630 SF Description RETAIL BLDG Inspector Assignment PY 2659 GATEWAY RD Lot Type COMMIND Sub Type COMM Job Address Suite Location OWNER LNR BRESSI COMMERCIAL INC Owner Remarks Phone 7604451279 Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By DAVID OBRIEN Entered By CHRISTINE Act Comments Comments/Notices/Holds Associated PCRs/CVs Original PC# PC 07-64 PCR08043 ISSUED BRESSI RANCH VILLAGE CENTER DEFFERED TRUSS SUBMITTAL ALL BUILDINGS PCR08044 ISSUED BRESSI RANCH VILLAGE CENTER, REV TO 13 PAGES(,DELTA 4) - PLUMBING/ELEC PCR08089 ISSUED BRESSI RANCH VILL CEN BLDG E, DELETE PARAPET, ADD MANSARD ROOF PCR08095 ISSUED BRESSI RANCH VILLAGE CENTER ADD DRAIN LINES FOR FIRE SPRINKLER RISER Inspection History Date Description 02/04/2009 89 Final Combo 01/29/2009 89 Final Combo 12/08/2008 39 Final Electrical 11/25/2008 39 Final Electrical 11/04/2008 84 Rough Combo 11/03/2008 84 Rough Combo 10/29/2008 39 Final Electrical 10/28/2008 23 Gas/Test/Repairs 10/28/2008 39 Final Electrical 10/27/2008 23 Gas/Test/Repairs Act PA PA PA PA AP NR PA AP NR PA Insp PY PY PY PY PY PY PY PY PY PY Comments paint roof vents EMR T-BAR EMR 3 UNITS City of Carlsbad Bldg Inspection Request For 12/08/2008 Permit* CB072912 Title BRESSI VILL -BLDG D 8,630 SF Description RETAIL BLDG Inspector Assignment PY Sub Type COMM 2659 GATEWAY RD Lot Type COMMIND Job Address Suite Location OWNER LNR BRESSI COMMERCIAL INC Owner Remarks STE 107 Phone 9092088193 Inspector Total Time Requested By PETE Entered By JANEAN CD Description 39 Final Electrical Act Comments Comments/Notices/Holds Associated PCRs/CVs Original PC# PC 07-64 PCR08043 ISSUED BRESSI RANCH VILLAGE CENTER DEFFERED TRUSS SUBMITTAL ALL BUILDINGS PCR08044 ISSUED BRESSI RANCH VILLAGE CENTER REV TO 13 PAGES(,DELTA 4) - PLUMBING/ELEC PCR08089 ISSUED BRESSI RANCH VILL CEN BLDG E, DELETE PARAPET, ADD MANSARD ROOF PCR08095 ISSUED BRESSI RANCH VILLAGE CENTER, ADD DRAIN LINES FOR FIRE SPRINKLER RISER Inspection History Date 11/25/2008 11/04/2008 11/03/2008 10/29/2008 10/28/2008 10/28/2008 10/27/2008 10/27/2008 09/23/2008 09/18/2008 09/18/2008 09/11/2008 09/11/2008 09/11/2008 08/14/2008 08/11/2008 Description 39 Final Electrical 84 Rough Combo 84 Rough Combo 39 Final Electrical 23 Gas/Test/Repairs 39 Final Electrical 23 Gas/Test/Repairs 39 Final Electrical 18 Exterior Lath/Drywall 17 Interior Lath/Drywall 18 Exterior Lath/Drywall 14 Frame/Steel/Bolting/Weldmg 17 Interior Lath/Drywall 84 Rough Combo 24 Rough/Topout 13 Shear Panels/HD's Act PA AP NR PA AP NR PA NR AP AP NR AP we AP PA AP Insp PY PY PY PY PY PY PY PY PY PY PY PY PY PY PY PY Comments T-BAR EMR 3 UNITS ROOF DRAINS City of Carlsbad Bldg Inspection Request For 11/25/2008 Permit* CB072912 Title BRESSI VILL-BLDG" D 8,630 SF Description RETAIL BLDG Inspector Assignment PY 2659 GATEWAY RD Lot Type COMMIND Sub Type COMM Job Address Suite Location OWNER LNR BRESSI COMMERCIAL INC Owner Remarks Phone 7604451279 Inspector Total Time Requested By DAVID Entered By CHRISTINE CD Description 39 Final Electrical Act Comments Comments/Notices/Holds Associated PCRs/CVs Original PC# PC 07-64 PCR08043 ISSUED BRESSI RANCH VILLAGE CENTER, DEFFERED TRUSS SUBMITTAL ALL BUILDINGS PCR08044 ISSUED BRESSI RANCH VILLAGE CENTER, REV TO 13 PAGES(,DELTA 4) - PLUMBING/ELEC PCR08089 ISSUED BRESSI RANCH VILL CEN BLDG E, DELETE PARAPET, ADD MANSARD ROOF PCR08095 ISSUED BRESSI RANCH VILLAGE CENTER, ADD DRAIN LINES 1:OR FIRE SPRINKLER RISER Inspection History Comments T-BAR EMR 3 UNITS Date 11/04/2008 11/03/2008 10/29/2008 10/28/2008 10/28/2008 10/27/2008 10/27/2008 09/23/2008 09/18/2008 09/18/2008 09/11/2008 09/11/2008 09/1 1/2008 08/14/2008 08/11/2008 08/11/2008 Description 84 Rough Combo 84 Rough Combo 39 Final Electrical 23 Gas/Test/Repairs 39 Final Electrical 23 Gas/Test/Repairs 39 Final Electrical 18 Exterior Lath/Drywall 17 Interior Lath/Drywall 18 Exterior Lath/Drywall 14 Frame/Steel/Bolting/Welding 17 Interior Lath/Drywall 84 Rough Combo 24 Rough/Topout 13 Shear Panels/HD's 15 Roof/Reroof Act AP NR PA AP NR PA NR AP AP NR AP we AP PA AP AP Insp PY PY PY PY PY PY PY PY PY PY PY PY PY PY PY PY ROOF DRAINS MANSARDS City of Carlsbad Bldg Inspection Request For 10/29/2008 Permit* CB072912 Title BRESSI VILL-BLDG D 8,630 SF Description RETAIL BLDG Inspector Assignment PY 2659 GATEWAY RD Lot Type COIMMIND Sub Type COMM Job Address Suite Location OWNER LNR BRESSI COMMERCIAL INC Owner Remarks Phone 7604451279 Inspector Total Time Requested By DAVID Entered By JANEAN CD Description 39 Final Electrical Act Comments Comments/Notices/Holds PCR08043 PCR08044 PCR08089 PCR08095 Associated PCRs/CVs Original PC# PC 07-64 ISSUED BRESSI RANCH VILLAGE CENTER, DEFFERED TRUSS SUBMITTAL ALL BUILDINGS BRESSI RANCH VILLAGE CENTER, REV TO 13 PAGES(.DELTA 4) - PLUMBING/ELGC BRESSI RANCH VILL CEN BLDG E DELETE PARAPET. ADD MANSARD ROOF BRESSI RANCH VILLAGE CENTER, ADD DRAIN LINES FOR FIRE SPRINKLER RISER ISSUED ISSUED ISSUED Inspection History Date Description 10/27/2008 23 Gas/Test/Repairs 10/27/2008 39 Final Electrical 09/23/2008 18 Exterior Lath/Drywall 09/18/2008 17 Interior Lath/Drywall 09/18/2008 18 Exterior Lath/Drywall 09/11/2008 14 Frame/Steel/Bolting/Weldmg 09/11/2008 17 Interior Lath/Drywall 09/11/2008 84 Rough Combo 08/14/2008 24 Rough/Topout 08/11/2008 13 Shear Panels/HD's 08/11 /2008 15 Roof/Reroof 08/07/2008 12 Steel/Bond Beam 08/04/2008 15 Roof/Reroof 07/30/2008 66 Grout 07/28/2008 13 Shear Panels/HD's 07/25/2008 11 Ftg/Foundation/Piers Act PA NR AP AP NR AP we AP PA AP AP AP AP AP AP AP Insp PY PY PY PY PY PY PY PY PY PY PY PY PY PY PY JM Comments 3 UNITS ROOF DRAINS MANSARDS DRY PACK COLUMN trash enclosure TRASH ENCLOSURE FTG Property Corporation October 28, 2008 Mr Paul York Building Inspector Building Department City of Carlsbad 1625 Faraday Avenue Carlsbad, CA 92008 Re Bressi Village Shop D - 2659 Gateway Road - Permit #CB072912 Shell Completion - Suite 107 Dear Paul, As requested, we are writing to document the status of Suite 107 as it relates to the completion of the Shop D shell building Our permitted drawings for this building call for a completed "Vanilla TI" suite in Suite 107 Per our drawings, Suite 107 includes ceiling, lighting, bathroom, drywall, etc as is typical in our other suites in the project However, we are currently in lease negotiations with tenants for Suite 107, and those tenants want the ceiling and lighting left out of the Landlord's work so they can customize this scope of work We have therefore stopped the ceiling and lighting installation to allow them to complete that installation as part of their TI work In light of the anticipated future TI work in Suite 107, we request that the City provide a final shell signoff for the Shop D building when all other required work is complete in the building, with the understanding that ceiling and lighting in Suite 107 will be incorporated into the TI work for this suite Please contact me with any questions you have regarding this letter and our Shop D building Thank you Sincerely, JeffWiJliams, for LNH O>I Bressi Retail, LLC OwnwvDeveloper of the Bressi Village project PROJECT DESIGN CONSULTANTS 70i. li STRI-I-.T, SLUE Sun SAX |)IKC;O, CA 92101 diy 235 6471 TEL dig 234 0349 FAX WWW I'KOIEC I I>nSIG\ COM File 321905 May 1,2008 CITY OF CARLSBAD Building Department 1635 Faraday Avenue Carlsbad, CA 92008-7314 SUBJECT '^BressisR'a^lf?illlWTCen1ter^FomfBeftification for Building Shop D To Whom It May Concern Project Design Consultants has field verified the form positions fertfBfilliMpPSlpEED^s shown on Sheet 7 of the Grading and Erosion Control Plans of the above-referenced project Upon our review of the survey data collected on April 29, 2008 the building footprint conforms horizontally and vertically within ±0 1-feet to the approved design Sincerely, Lawrence D Naiman, LS Associate LS 5163, Exp 6/30/09 R \WP\LETTER\3200\3219 05FormCert(2)ShopD_PA1 5 doc SA\ DIF.GO rilOLMX T1.-A1 KCL'I.A • BAKF.RSFIELD Office Locations Orange County Corporate Branch 2992 E La Raima Avenue Suite A Anaheim, CA 92806 Tel 7146322999 Fax 7146322974 San Diego Imperial County 6295 Ferns Square Suite C San Diego, CA 92121 Tel 858 537 3999 Fax 858 537 3990 Inland Empire 14467 Meridian Parkway Building 2A Riverside, CA 92518 Tel 951 653 4999 Fax 951 653 4666 Indio 44917 Golf Center Parkway Suite 1 Indio, CA 92201 Tel 760 342 4677 Fax 760 342 4525 OC/LA/lnland Empire Dispatch 800 491 2990 San Diego Dispatch 888 844 5060 www mtglmc com FINAL REPORT FOR SPECIAL INSPECTION AND MATERIAL TESTING Geotechnical Engineering Construction Inspection Materials Testing Environmental Date December 15,2008 To City of Carlsbad (c/o Mr J Paul York) Building Inspector 1635 Faraday Avenue Carlsbad, CA 92008 MTGL Project No 1424-A20 MTGL Log No 08-2180 SUBJECT SATISFACTORY COMPLETION OF WORK REQUIRING SPECIAL INSPECTION AND MATERIAL TESTING PERMIT NO CB072912 (Shop D) PROJECT NAME/ADDRESS Bressi Ranch Village Center / 2659 Gateway Road Carlsbad, California I declare under penalty of perjury that, to the best of my knowledge, the work requiring special inspection, material sampling and testing, for the structure/s constructed under the subject permit is in conformance with the approved plans, the inspection and observation program and other construction documents, and the applicable workmanship provisions of the Uniform Building Code Executed on December 15,2008 The work which we provided Special Inspection/Testing consisted of Reinforcing Steel, Concrete and Built-Up Roofing A If the inspection services were provided by an approved material testing laboratory or special inspection agency TESTING AGENCY MTGL, Inc 7313 Carroll Road, Suite G San Diego, C A 92121 RESPONSIBLE MANAGING ENGINEER OF THE TESTING LABORATORY OR SPECIAL INSPECTION AGENCY NAME (PRINT OR TYPE) Eduardo C Dizon / MTGL, Inc State of California Registration Number C 57217 Expiration Date 12/31/09 B) If the inspection services were provided by an independent certified special inspector NASPECIAL INSPCETOR'S NAME (PRINT OR TYPE) Registration Number A V SIGNATURE JN YA_^_-^W^_X>-Q<^\_j cc Mr Jeff Williams / LNR Property Corporation Mr David Obnen / Grant General Contractors Expiration Date f Corporate 2992 E LaPalmaAve Anaheim, CA 92806 Tel 7146322999 Fax 7146322974 Dispatch 800 491 2990 Ste A San Diego/Imperial County 7313 Carroll Rd Ste G San Diego, CA 92121 Tel 8585373999 Fax 8585373990 Dispatch 8888445060 DAILY INSPECTION REPORT Inland Empire 14467 Meridian Pkwy.Bldg 2-A Riverside, CA92518 Tel 951 653 4999 Fax 951 653 4666 Dispatch 800 491 2990 DSA/CITYFile# DSA/OSHPD APPL #. DSA/LEA#Report #_; Special Inspection Reports must be distributed to the parties listed below within 14 days of the inspection Reports of non-compliant conditions must be distributed immediately Separate reports shall be prepared for each type of special inspection, on a daily basis Eacft report shall be completed and signed by the special inspector conducting the inspection TYPE OF INSPECTION D ENGINEERED FILL D FOUNDATION D BACKFILL D BATCH PLANT D PT CONCRETE D SHOTCRETE G CONCRETE D MASONRY D HIGH STRENGTH BOLTING D WELDING D SHOP WELD G FIRE^ROOFING D ANCHOR/DOWEL D NDE FIELD D NDESHOP D DSA/OSHPD/PROJECT APPROVED DOCUMENTS AVAILABLE APPROVED PLANS YD ND SOIL REPORT YD ND SPECS YD ND APPROVED SHOP DRAWING Y a ND CONTRACTORS EQUIPMENI / MANPOWE AREA GRID LINES PIECES INSPECTED STRUCTURAL NOTES DETAIL OR RFIS USED £ REWORK AS PERCENT OF ALL WORK TODAY y /- \6iJ9*( THE WORK WASD WAS NOT D Inspected in accordance with the requirements of the DSA/OSHPD/PROJECT approved documents MATERIAL SAMPLING WASD WAS NOT D N/A^Q, Performed in accordance with DSA/OSHPD/PROJECT approved documents THE WORK INSPECTED METD DID NOT MEET D / THE requirements of tbe/fsA/OSHPD/PROJECT approved documents Samples taken Weather (Uuyi^ ^ Temp cc Proiect Architect Structural Engineer DSA Regional Office School District Contractor Building Department Owner Verified by Corporate 2992 E la Raima Ave Ste A Anaheim, CA 92806 Tel 7146322999 Fax 7146322974 "www mtglmc com Dispatch 800 491 2990MMJV^ San Diego/Imperial County 7313 Carroll Rd Ste G San Diego, CA 92121 Tel 8585373999 Fax 858 537 3990 Dispatch 8888445060 Inland Empire 14467 Meridian Pkwy, Bldg 2-A Riverside, CA 92518 Tel 951 653 4999 Fax 951 653 4666 Dispatch 800 491 2990 DAILY INSPECTION REPORT DSA/CITY File #MTGL Project # . Permit #J Report #' Special Inspection Reports must be distributed to the parties listed below within 14 days of the inspection Reports of non-compliant conditions must be distributed immediately Separate reports shall be prepared for each type of special inspection, on a daily basis Each report shall be completed a/id signed by the special inspector conducting the inspection DSA/OSHPDAPPL#. DSA/LEA# nspectiop, on a daily basis Each reportM^fricUjr TIME ARRIVE TJMI -4UJJN IE DEPARTED \t>D> TRffi/EL TIME lNCH TIME SUB CO (TRACTOR INSPECTION ADDRESS ADDRESS OF PROJECT TYPE OF INSPECTION D ENGINEERED FILL C FOUNDATION D BACK FILL D BATCH PLANT D PT CONCRETE D SHOTCRETE D CONCRETE D MASONRY Cl HIGH STRENGTH BOLTING D WELDING a SHOP WELD D FIREPROOFING D ANCHOR/DOWEL a NDE FIELD a NDESHOP LINGJWIRE a DSA/OSHPD/PROJECT APPROVED DOCUMENTS AVAILABLE APPROVED PLANS SOIL REPORT YD ND N D SPECS Y^ND APPROVED SHOP DRAWING N D STRUCTURAL NOTES DETAIL OR RFIS USED C/rQgAjML ?LfltL M»<V 6 \i lL-~f~ — RERK AS PERCENT OF ALL WORK TODAY PERCENT PROJECT COMPLETE THE WORK WAS fr- WAS NOT a Inspected in accordance with the requirements of the DSA/OSHPD/PROJECT approved documents MATERIAL SAMPLING WAS a WAS NOT a N/Aa Performed in accordance with DSA/OSHPD/PROJECT approved documents cc Project Architect Contractor Structural Engineer Building Department DSA Regional Office Owner School District THE WORK INSPECTED META DID NOT MEET D THE requirements of the DSA/6'SBPQ/PROJECT approved documents Samples taken /V,//L Weather £~4J>-^jf~ '& Temp (o "i? '" 7 /^ 2J2.-frs^ Signature OT^pecfal'tiTfepector -. \r_L**l t&QsrfVi}> Print Name Certification Verified by _ Corporate 2992 E La Raima Ave Ste A Anaheim, CA 92806 Tel 7146322999 Fax 714 632 2974 Dispatch 800 491 2990 r San Diego/Imperial County 7313 Carroll Rd Ste G San Diego, CA 92121 Tel 8585373999 Fax 858 537 3990 Dispatch 8888445060 Inland Empire 14467 Meridian Pkwy, Bldg 2-A Riverside, CA 92518 Tel 951 653 4999 Fax 951 653 4666 Dispatch 800 491 2990www mtglmc com MTGL Project # Permit # Report #, Special Inspection Reports must be distributed to the parties listed below within 14 days of the inspection Reports of non-compliant conditions must be distributed immediately Separate reports shall be prepared for each type of special inspection, on a daily basis Each report shall be completed and signed by the special inspector conducting the inspection DSA/CITY File # DSA/OSHPD APPL #. DSA/LEA# TYPE OF INSPECTION D ENGINEERED FILL l~ FOUNDATION D BACK FILL G BATCH PLANT DPT CONCRETE H SHOTCRETE Q CONCRETE D MASONRY D HIGH STRENGTH BOLTING D WELDING D SHOP WELD D FIREPROOFING D ANCHOR/DOWEL D NDE FIELD D NDESHOP D CEUJNG WIRE D D D DSA/OSHPD/PROJECT APPROVED DOCUMENTS AVAILABLE APPROVED PLANS Y g$, N D SOIL REPORT YD ND SPECS YL£kJ\ID APPROVED SHOP DRAWING N D MATERI«£ USED M CON :H REPORT NO ORIMATERIW. Tf ST REPOR; \&QMb \t_j_ CONTRACTORS EQUIPMENT / MANPOWER USED AREA GRID LINES PIECES INSPECTED STRUCTURAL NOTES DETAIL OR RFIS USED RE \A\ REWORK AS PERCENT OF ALL WORK TODAY PERCENT PROJECT COMPLETE THE WORK WASD WAS NOT D Inspected in accordance with the requirements of the DSA/OSHPD/PROJECT approved documents MATERIAL SAMPLING WASD WAS NOT H Performed in accordance with DSA/OSHPD/PROJECT approved documents cc Project Architect Contractor Structural Engineer Building Department DSA Regional Office Owner School District THE WORK INSPECTED METH, DID NOT MEET D THE requirements of the DySA/OSJdPD/PROJECT approved documents Samples takep / V / ^"v „ - •. Weather (jLt^y^ ' . Temp <45 "" Sigjature of ^pejcial Inspector Certification #. Verified by Corporate 2992 E La Palnia Avenue, Suile A, Anaheim, CA 92806 Tel (714)632-2999 Fax (714)632-2974 Branch 7313 Carroll Road. Suile G, San Diego CA 92121 Tel (858)537-3999 Fax (85S)537-3WO Branch 14467 Meridian Parkway Bldg 2A, Riverside, CA 92518 Tel (951)653-4999 Fax (951)653-4666 Report of COMPRESSIVE STRENGTH-MORTAR ASTM C270 CITY OF CARLSBAD-BLDG INSPECTION DEPT 1635 FARADAY AVENUE CARLSBAD. CA 92008 Client LNR PROPERTY CORPORATION Set No 8-02978 File No N/A Permit No N/A Project No 1424A20 Project Name BRESSI RANCH VILLAGE CENTER CARLSBAD GATEWAY ROAD CARLSBAD. CA * Age (Days) 28 28 28 Date Tested 10/29/2008 10/29/2008 10/29/2008 Nominal Size 2X4 2X4 2X4 Actual Area (Sq Inch) 3 14 3 14 3 14 Load dhs) 7,040 7.150 7.200 Strength (psi) 2,240 2,280 2.290 Type of Fracture N/A N/A N/A Specified Strength 1,800 PSI Sampled By JEREMIAH BIETZ ASTM C172 Date Sampled 10/1/2008 Date Received 10/3/2008 Location CMU WALL - GRID LINE 1 / A - A 8. 2'-8" TO 4-8" ABOVE FINISHED FLOOR % Concrete Supplier SPECIFIED MIX Mix No . TYPE S Ticket No Water added at Site gal By Cement Type Concrete Temp Ambient Temp "F "F ASTM C1064 ASTM C1064 Mix Time mm Slump in ASTM C143 Tested at San Diego Remarks Distribution LNR PROPERTY CORPORATION CITY OF CARLSBAD-BLDG INSPECTION DEPT GRANT GENERAL CONTRACTORS CHILDS, MASCARI AND WARNER ARCHITECTS GSSI **LAB COPY** Respectfully Submitted, MTGL, Inc Eduardo Dizon, R C E 2270 PSI 28-day compression test complies with the specified strength www mtghnc.com Corporate 2992 E La Palma Ave Ste A Anaheim, CA 92806 Tel 714 632 2999 Fax 714 632 2974 Dispatch 800 491 2990 San Diego/Imperial Coui 7313 Carroll Rd Ste G San Diego, CA 92121 Tel 8585373999 Fax 858 537 3990 Dispatch 888 844 5060 Inland Empire: 14467MeridianPkwy.Bldg 2-A Riverside, CA 92518 Tel 9516534999 Fax 9516534666 Dispatch 8004912990 MTGLProject# /Y9T 4<Ai Permit #_ Report #_P6 / DF / DAILY INSPECTION REPORT DSA/CITYFile#. DSA/OSHPDAPPL#. DSA/LEA# Special Inspection Reports must be distributed to the parties listed below within 14 days of the inspection Reports of non-compliant conditions must be distributed immediately Separate reports shall be prepared for each type of special inspection, on a daily basis Each report shall be completed and signed by the special inspector conducting the inspection PROJECT NAME DATE ARCHITECT TIME ARRIVED TIME DEPARTED ENGINEER TRAVEL TIME LUNCH TIME CONTRACTOR SUBCONTRACTOR INSPECTION ADDRESS ADDRESS OF PROJECT TYPE OF INSPECTION D ENGINEERED FILL D FOUNDATION D BACKFILL D BATCH PLANT D PT CONCRETE nSHOTCRETE Jj<CONCRE D MASONRY D HIGH STRENGTH BOLTING D WELDING D SHOP WELD D FIREPROOFING D ANCHOR/DOWEL D NDE FIELD D NDE SHOP D CEILING WIRE D D D DSA/OSHPD/PROJECT. APPROVED DOCUMENTS AVAILABLE APPROVED PLANS Y/f ND SOIL REPORT YD ND SPECS Yfc^ND APPROVEDSHOP DRAWING YD ND MATERIALS USED BY CONTRACTOR (INCLUDE RESEARCH REPORT NO OR MATERIAL TEST REPORTS) 3 CONTRACTORS EQUIPMENT / MANPOWER USED STRUCTURAL NOTES, DETAIL, OR RFIS USED REMARKS IHCLUDmeMEETlHGS. REWORK AS PERCENT OF ALL WORK TODAY PERCENT PROJECT COMPLETE THE WORK WAS/SLWASNQTD Inspected in accoraance with the requirements of the DSA/OSHPD/PROJECT approved documents MATERIAL SAMPLING WAS tf WAS NOT D N/AD Performed in accordance with DSA/OSHPD/PROJECT approved documents cc Protect Architect Contractor Structural Engineer Building Department DSA Regional Office Owner School District THE WORK INSPECTED METD DID NOT MEET D THE requirements^ toe DSA/OSHPD/PROJECT aoproved documents Samples taken (T) &!< It JSignature of Special Inspector Certificate <Verified by Corporate* 2992 E La Anaheim, CA 92806 Tel 714 632 2999 Fax 7146322974 San Diego/Imperial 7313 Carroll Rd Ste G San Diego. CA 92121 Tel 858 537 3999 Fax 8585373990 Inland Empire: 14467 Meridian Pkwy, Bldg 2-A Riverside, CA 92518 Tel 951 653 4999 Fax 9516534666 wwwrrngnric.com ui&|jdu,ii ouu ta i ^ou MTGLProiect*- V4l H M& Permit #^"fc> "7lQo> Report* PG DF Special Inspection Reports must be distributed to the parties lis Separate reports shall be prepared for each type of special msp PROJECT NAME •. uia|Jdiuii ooo ont auuu u DAILY INSPECTION °SWCTVRtt' REPORT DSA/OSHro" DSA/LEA#' lapmuii ouutai ^uau >PL#- Mirn-f ted below within 1 4 days of the inspection Reports of non-compliant conditions must be distnttpted immediately DATE, - ARCHITECT, . & „, • '" TWTE ARRIVED ' TIME DEPARTED ENGINEER CONTRACTOR f .^Vrffi ^^ » INSPECTION ADDRESS TYPE OF INSPECTION D BATCH PLANT DENGHPR.EPFILL „ D PT CONCRETE D FOUNDATION D SHOTCRETE D BACK FILL D CONCRETE TRAVEL TIME LUNCH TIME SUBCONTRACTOR /WDRESSOF PROJECT & MASONRY D FIREPROOFING D HIGH STRENGTH BOLTING D ANCHOR/DOWEL D WELDING ' D NDE FIELD ' D SHOP WELD D NDE SHOP D CEILING WIREnv an DSA/OSHPD/PROJECT AVAILABLE SOIL REPORT YD ND SPECS YJ* ND APPROVED DOCUMENTS APPROVED PLANS Y Ifcr N D - APPROVED SHOP DRAWING Y D N D MATERIALS USED BY CONTRACTOR UNCLUDE RESEARCH REPORT 110 OR M L r* \^ "•a \ c>\ - A >P ^i/ j 3f » C\\ W< WERIAL TEST REPORTS) afi^Vioi^ } -TLOOOfiT/ CONTRACTORS EQUIPMENT / MANPOWER USED fX^Ct-v \J\\>\fGi\*>v , 7~t/'A\]$jr' <n{^i»^yyf • AREA GRID LINES, PIECES INSPECTED• JS .1 •- f . ** S * ^* A A i m^ ' fJ^ VL? ^* I '• •^^ I j^« L<i \sJfr 1 )"; STRUCTURAL NOTES, DETAIL, OR RRS USED ' REMARKS mcLwmGH&mes. , i \<Pjf £*tv*\fdi Q*\ iv\I/Vi^rio«^ o Y\O*&t* CLI»O\JC \Qif£t>'fY*>eu 0vYOl*f f^*Vlv»/f J IA *a 0>£*i i ..iw' • f- Giirtoutr pJa r^ r* e>* V / ^o^l S^l.c fLv^P f^V fe^^. ^ £*»J~• f y ilaJri&i frv ^ Lit /Or d -rW-o^ ^ / i/ REWORKl^l*aiCENT OF ALL WORK TODAY THE WORK 4p^ WAS NOT D Inspected 1ft|^glance with the requirements of the DSA/OS approved documents.'" MMrERIALSMVLING WA§£ WAS NOTOJ^A D Performed in accordance with DSA/OSHPD/PROJEbiT approve PERCENT PROJECtCOWPLETE4 * •~>-v- v THE WORK INSPECTED MET» Qlfl NQD« HPD/PROJ£W- THE requirements of the DSA/6SHPD/PROJK Samples taken * x \&* <ai(^"^'3 Weather Clcn*&'~/ Temp^^ »• d-dpsuments y^t>c^^, ^,— , s* .- .-*• ' EET'a — - T approved documents t-o'tz* 'i $ •r'i v ^ -•^-••^* "•^g 1•>; .-V j -ii cc Project Architect Contractor Structural Engineer' Building Department DSA RegionalOffice Owner School District Certification # Verified by 2992|E,LaBalma Anaheim, CA 92806 Tel 7146322999 Fax 7146322974 Dispatch 8004912990 MTGL Project* Permit # San Diego/Imperial 7313 Carroll Rd Ste G San Diego, CA 92121 Tel 8585373999 Fax 858 537 3990 Dispatch 888 844 5060 DAILY INSPECTION REPORT Inland Empire: 14467 Meridian Pkwy.Bldg 2-A Riverside, CA 92518 Tel 951 653 4999 Fax 951653.4666 Dispatch 8004912990 DSA/CITYFile#. DSA/OSHPDAPPL*. DSA/LEA#- Special Inspection Reports must be distributed to the parties listed below within 14 days of the inspection Reports of non-compliant conditions must be distributed immediately Separate reports shall be prepared for each type of special inspection, on a daily basis Each report shall be completed and signed by the special inspector conducting the inspection I DATE i,iu,rU>\a TIMEARI TIME DEPARTED ENGINEER TRAVEL TIME LUNCH TIME CONTRACTOR 6c/ SUBCONTRACTOR INSPECTION ADDRESS 'ADDRESS OF PROJECT TYPE OF INSPECTION G ENGINEERED FILL FOUNDATION" D BACKFILL D BATCH PLANT D PT CONCRETE D -SHOTCRETE ^CONCRETE D MASONRY D HIGH STRENGTH BOLTING D WELDING D SHOP WELD D Fl REPROOFING D ANCHOR/DOWEL D NDE FIELD D NDE SHOP D CEILING WIREaaa DSA/OSHPD/PRDJECT. APPROVED DOCUMENTS AVAILABLE APPROVED PLANS Y» N D SOIL REPORT YD ND SPECS YS>NG APPROVED SHOP DRAWING YD ND MATERIALS USED BY CONTRACTOR (INCLUDE RESEARCH REPORT NO OR MATERIAL TEST REPORTS) » HALT CONTRACTORS EQUIPMENT/ MANPOWER USED y'"^(? / AREA GRID LINES PIECES INSPEpTED , U •"" STRUCTURAL NOTES, DETAIL. OR RFIS USED"RAL NOTES, DETAI k 1.." o REWORKS POtCEflnOF ALL WORK TtJDAY PERCENT PROJECT COMPETE THE WORK' WAS5» WAS NOT D" ' ,-—^ Inspected in accordance,with the requirements of the DSA/OSHPD/PROJE8T approved doiiSmlntsr" ' -•? - ' MATERIAL SAMPLING WAS a WAS NOTD J/AD Performed in accordance with DSA/OSHPD/PROJEJx approved docuf^ents rTHE WORK INSPECTED THE requirements of the DSA/OSH cc Project Architect Contractor Structural Engineer BuHflmg Department DSA Regional Office Owner School Distnct Samples^taken Weather. JT/ouM/ -^ ETD" approved do&irnents Temp Signature of Special Inspector Pnnt Name Certification f Verified by -• «*t • •.,-. -.;.. www mtglinc com Corporate/ 2992 E L| Raima Anaheim, CA 92806 Tel 7146322999 Fax 7146322974 Dispatch 8004912990 MTGL Project f Permit #J Report #_ n Diego/Imperial 7313 Carroll Rd Ste G San Diego, CA 92121 Tel 858 537 3999 Fax 858 537 3990 Dispatch 888 844 5060 DAILY INSPECTION REPORT Inland Empire: 14467 Meridian Pkwy, Bldg 2-A Riverside, CA 92518 Tel 951653.4999 Fax 9516534666 Dispatch 8004912990 DSA/CITYFile# PG DF DSA/OSHPDAPPL#'_ DSA/LEA* Special Inspection Reports must be distributed to the parties listed below within 14 days of the inspection Reports of non-compliant conditions must be distributed immediately Separate reports shaH be prepared for each type of special inspection, on a daily basis Each report shall be completed and signed by the special inspector conducting the inspection JECTNAME DATE CHITEC TIME TIME DEPARTED ENGINEER TRAVEL TIME LUNCH TIME CONTRACTOR rB C Ot INSPECTION ADDRESS ADDRESS OF P TYPE OF INSPECTION D ENGINEERES-flU, D FOUNDATION D BACK FILL — D BATCH PLANT DPT CONCRETE D SHOTCRETE S CONCRETE D MASONRY D HIGH STRENGTH BOLTING - D WELDING D SHOP WELD D Fl REPROOFING D ANCHOR/DOWEL D NDE FIELD D NDE SHOP D CEILINGJVIREfz ILt ucw-an. DSA/OSHPD/PROPI; APPROVED DOCUMENTS AVAILABLE APPROVED PLANS SOIL REPORT YD ND N D SPECS Yfl ND APPROVED SHOP DRAWING YD ND MATERIALS USED BY CONTRACTOR (INCLUDE RESEARCH REPORT NO tfv«x ^V»H - 9ev MATERIAL TEST REPORTS) CONTRACTORS EQUIPMENT /MANPOWER USED AREA GRID LINES PIECES INSPECTED i**\ CTa V» O t>*\ JPotaV>»sr^ .^v.^^ JA\r>fif .4 A ~ A Irt STRUCTURAL NOTES DETAIL OR RFIS USED wEMARKS IMCLUOmeitEETmS- t-Vrve f CiV\o^ oV REWORK ASTP6RTJENT 0 ALLlVORKf ODAY 'PERCENT PRO-JECT-eONrPtETE- THE WORK WAS& WASNdTtT " - - - -- Inspected in accordance with the requirements of the DSA/OSHPD/PROJOT approved docdmerlfs * * "" *•- - — v— MATERIAL SAMPLING WAS %$ WAS NOT D N/A D Performed in accordance with DSA/OSHPD/PRlHEC^pproved documents cc Project Architect Contractor Structural Engineer Building Department DSA Regional Office Owner School District THE W08JUNSWCTEP,.METES'DID NOT MEETD THE requirements of the DSA/OSHro/P"fiTOE$T approved dociimemi " Samples taken Weather JV*^ Temp Signature of Special Inspector Print Name 07-2? AS" WWW Corporate. 2992 E Laj Anaheim, CA 928*06 Tel: 714 632 2999 Fax 7146322974 Dispatch 8004912990 MTGL Project #-.VfLZfi Permit #. Report #_PG -77 San Diego/Imperial A 7313 Carroll Rd Ste G San Diego, CA 92121 Tel 858 537 3999 Fax 858 537 3990 Dispatch 888 844 5060 DAILY INSPECTION REPORT Inland Empire: 14467MeridianPkwy.Bldg 2-A Riverside, CA 92518 Tel 9516534999 Fax 9516534666 Dispatch 8004912990 DSA/CITYFile#-_ DF DSA/OSHPDAPPL*-. DSA/LEA# Special Inspection Reports must be distributed to the parties listed below within 14 days of the inspection Reports of non-compliant conditions must be distributed immediately Separate reports shall be prepared for each type of special inspection, on a daily basis Each report shall be completed and signed by the special inspector conducting the inspection PROJECT NAME DATE ARCHITE tv \t>ilVED TIME DEPARTED I . OO ENGINEER TRAVEL TIME LUNCH TIME CONTRACTORlun L (V &* V SUB CONTRACT INSPECTION ADDRESS ADDRESS OF PROJECT TYPE OF INSPECTION D ENGINEERED RLL D FOUNDATION D BACK FILL D BATCH PLANT D PT CONCRETE D SHOTCRETE £TCONCRETE D MASONRY D HIGH STRENGTH BOLTING D WELDING D SHOP WELD a FIREPROOFING D ANCHOR/DOWEL D NDE FIELD D NDE SHOP D CEILING WIREaaa DSA/OSHPD/PROJECT- APPROVED DOCUMENTS AVAILABLE APPROVED PLANS Y§f ND SOIL REPORT YD ND SPECS Y^f ND APPROVED SHOP DRAWING YD ND MATERIALS USED BY CONTRACTOR (INCLUDE RESEARCH REPORT NO OR MATERIAL TEST REPORTS) ^/CONTRACTORS EQUIPMENT / MANPOWER USED , AREA, GRID LINES PIECES INSPECTED A RAL NOTES, DETAIL OR RFIS USED REMARKS mCLUmMBIKETIH6S <\ r REWORK AS PERCENT OF ALL WORK TODAY PERCENT PROJECT COMPLETE THE WORK WASH WA'SNOTD Inspected in accordance with the requirements of the DSA/OSHPD/PROJECT approved documents MATERIAL SAftPUNG WAS H WAS NOT D N/AD Performed in accordance with DSA/OSHPD/PROJECT approved documents cc Project Architect Contractor Structural Engineer Building Department DSA Regional Office Owner School District THE WORK INSPECTED MET §T DID NOT MEET D THE requirements ofttie DSA/OSHPD/PROJECT app Samples taken "j. 5 a V o \, **> Weather ^f^ (Cf-^) ^ Temp ignature of Special Inspector Print Name Certification, Verified by www mtglinc.com MTGL Project # Permrt I Report* Corporate \ 2992 E LaPalma&e Anaheim, CA 92806 Tel 7146322999 Fax 7146322974 Dispatch 8004912990 San Diego/Imperial Co 7313 Carroll Rd Ste G in Diego, CA 92121 'el 8585373999 Fax 858 537 3990 Dispatch 888 844 5060 \ IrlandlI Empire. \ 1|I67 Meridian Pkwy, Bldg 2-A Riverside, CA 92518 Tel 9516534999 Fax 9516534666 Dispatch 800 491 2990 DAILY INSPECTION REPORT DSA/CITYFile# PG DF DSA/OSHPDAPPL*. DSA/LEA# _ Special Inspection Reports must be distributed to the parties listed below within 14 days of the inspection. Reports of non-compliant conditions must be distributed immediately Separate reports shall be prepared for each type of special inspection, on a daily basis Each report shall be completed and signed by the special Inspector conducting the Inspection )JECTNAME ^ \. •-"•': v*"" >. DATE RIVED TIME DEPARTED ENGI TRAVEL TIME HTIME CONTRACTOR TOR INSPECTION ADDRESS ADDRESS OF PROJECT TYPEOFIHSJWCTIO* D ENGINEERED FILL D FOUNDATION D BACK FILL - fl BATCH PLANT D PT CONCRETE D SHOTCRETE ^ CONCRETE D MASONRY D HIGH STRENGTH BOLTING D WELDING D SHOP WELD D FIREPROOFING P ANCHOR/DOWEL D NDE FIELD D NDE SHOP D CHLINGWI JS iMt O IRE *. *^ DSA/OSHPD/PROJECT- APPROVED DOCUMENTS AVAILABLE APPROVED PLANS SOIL REPORT YD ND N d SPECS. Y» ND APPROVED SHOP DRAWING Y D MATERIALS USED CONTRACTOR (INCLUDE RESEARCH REPORT NO OR MATERIAL TEST REPORTS)w L CONTRACTORS EQUIPMENT/ MANPOWER USED ARGRID LINEStPI£C6S INSRECTEO r< C*»\V 0£_ NOTES DETAIL ORRFISUSED jKMARKS w /K*/1 REWORK AJ PERCENT OF ALL WORK TODAY PERCENT PROJECT COMPLETE THE WORK WAS ^ WAS NOT D Inspected in aceotdanee wfth Hie requirements of the DSA/OSHPD/PT?OJE5T> approved documents ^ MATERIAL SAMPLING WASD WAS NOT D N/AD Performed in accordance with DSA/OSHPD/PROJECT approved documents cc Project Architect Contractor Structural Engineer Building Department DSA Regional Office Owner School District Tfft WORK INSPECTED MFT» DlDJiOWpTD'' •*'• THE requirements of the DSA/OSHPD/fROJEC) approved documents Samples taken _^_ Weather Qt»e^CO>5> Temp. OT-Zfli. 1L5*> G.A.-TBIU FOOTING OBSERVATION SUMMARY Leighton and Associates, Inc * IEIOHTON OROUP COMPANY Project Name Location. Plan File No Date Project No • Permit No.:Unit/Phase/Lot(s): Referenced Geotechnical Report(s)- Observation Summary Initials M-Date Jnitials Date Jnitials _Date Initials A representative of Leighton and Associates observed onsite soil the site are substantially in conformance with those assumed in the geotechnical ni^port: A representative of Leighton and Associates observed and measured footing excavation depth/width Footing excavations extend to proper depth and bearing strata and are in general conformance with recommendations of the geotechnical report. _*f A representative of Leighton and Associates measured footing setback from slope face. The setback was in general accordance with the recommendations of the geotechnical report. QO <- \ - Notes to Superintendent/Foreman 1. Footing excavations should be cleaned of loose debns and thoroughly moistened just prior to placing concrete. 2 Based on expansion potential of underlying soils, presoakmg of soil below slabs may be recommended Consult the geotechnical report for presoakmg recommendations We note that clayey soils may take an extended; period of time and the contractor should schedule accordingly 3 In the event of 9 site change subsequent to our footing observation and prior to concrete placement (i e, heavy rain»e|c.},iwe should be contacted to perform additional site observations Note 1 Soil compaction test results, including depth of fill, relative compaction, bearing values, and soil expansion'Index test results are contained in the As-Graded Geotechnical Report provided at the completion of grading. Date FIELD COPY Q7- Leighton Consulting, Inc A LEIGHTON GROUP COMPANY FOOTING OBSERVATION SUMMARY Project Name Location Plan File No Date Project No Permit No Unit/Phase/Lot(s) Referenced Geotechnical Report(s) Observation Summary Initials A representative of Leighton Consulting observed onsite soil conditions Soil conditions at the \7«c$Date s^6 are substantially in conformance with those assumed in the geotechnical report Initials Date Initials Date Initials fe- 17-oarDate A representative of Leighton Consulting observed and measured footing excavation depth/width Footing excavations extend to proper depth and beanng strata and are in general conformance with recommendations of the geotechnical report A representative of Leighton Consulting measured footing setback from slope face The setbackwas ln general accordance with the recommendations of the geotechnical report ~D*«-t Notes to Superintendent/Foreman 1 Footing excavations should be cleaned of loose debris and thoroughly moistened just prior to placing concrete 2 Based on expansion potential of underlying soils, presoaking of soil below slabs may be recommended Consult the geotechnical report for presoaking recommendations We note that clayey soils may take an extended period of time and the contractor should schedule accordingly 3 In the event of a site change subsequent to our footing observation and pnor to concrete placement (i e , heavy rain, etc.), we should be contacted to perform additional site observations Note to Building Inspector 1 Soil compaction test results, including depth of fill, relative compaction, beanng values, and soil expansion index test results are contained in the As-Graded Geotechnical Report provided at the completion of grading <ar\~l- For Leig&dn Consulting, Inc Date 609 R1-05 CLIENT COPY en - Corporate 2992 E La Raima Ave Ste A Anaheim, CA 92806 Tel 7146322999 Fax 7146322974 Dispatch 800 491 2990 San Diego/Imperial County 7313 Carroll Rd, Ste G San Diego, CA 92121 Tel 8585373999 Fax 8585373990 Dispatch 8888445060 Inland Empire 14467 Meridian Pkwy , Bldg 2A Riverside, CA 92518 Tel 951 653 4999 Fax 951 653 4666 Dispatch 800 491 2990 DAILY INSPECTION REPORT DSA/CITY File #MTGL PROJECT* 1424A20 Permit # CB072912 Report # Page 1 of 1 Special Inspection Reports must be distributed to the parties listed below within 14 days of the inspection Reports of non-compliant conditions must be distributed immediately Separate reports shall be prepared for each type of special inspection on a daily basis Each report shall be completed and signed by the special inspector conducting the inspection DSA/OSHPD Appl #. DSA/LEA* PROJECT NAME Bressi Ranch Village Center Date 2-23-08 ARCHITECT TIME ARRIVED 3 00 TIME DEPARTED 5 00 ENGINEER TRAVEL TIME 5 LUNCH TIME CONTRACTOR Grant construction SUB CONTRACTOR INSPECTION ADDRESS same ADDRESS OF PROJECT 2659 Gateway Rd Carlsbad TYPE OF INSPECTION D ENGINEERED FILL D FOUNDATION D BACK FILL D BATCH PLANT D PT CONCRETE D SHOTCRETE D CONCRETE D MASONRY D HIGH STRENGTH BOLTING D WELDING D SHOP WELD D FIREPROOFING D ANCHOR/DOWEL D NDE FIELD D NDE SHOP D CEILING WIRE H Reinforcing Steel D D DSA/OSHPD PROJECT APPROVED DOCUMENTS AVAILABLE APPROVED PLANS Y D N a SOIL REPORT Y H N D SPECS Y B N D APPROVED SHOP DRAWING Y [3 N D MATERIALS USED BY CONTRACTOR (INCLUDE RESEARCH REPORT NO OR MATERIAL TEST REPORTS) A615 A706 Grade 60 rebar CONTRACTORS EQUIPMENT/MANPOWER USED AREA, GRID LINES, PIECES INSPECTED Shop D Trellis collumn footing STRUCTURAL NOTES, DETAIL OR RFIS USED REMARKS INCLUDING MEETINGS Onsrte to inspect the reinforcing steel at the above location s per the approved plans and details I checked the bar size placement lap cove and clearance The above mentioned areas are ready for concrete at the time of inspection REWORK AS PERCENT OF ALL WORK TODAY PERCENT PROJECT COMPLETE THE WORK WAS S WAS NOTQ Inspected in accordance with the requirements of the DSA/OSPHD Project approved documents MATERIAL SAMPLING WAS D WAS NOT D N/A & Performed in accordance with DSA/OSPHD Project approved documents THE WORK INSPECTED MET H DID NOT MEET D The requirements of the DSA/OSPHD Project approved documents Samples taken Weather-Temp cc Project Architect Structural Engineer DSA Regional Office School District Contractor Building Department Owner Signature of Special Inspector Josh Cooper Krmt Name Certification £5269064-4.9 (. Verified by Corporate 2992 E La Raima Avenue. Suite A, Anaheim, CA 92806 Tel (714)632-2999 Fax (714)632-2974 Branch 7313 Carroll Road. Suite G. San Diego, CA 92121 Tel (858)537-3999 Fax (858)537-3990 Branch 14467 Meridian Parkway Bldg 2A, Riverside, CA 92518 Tel (951)653-4999 Fax (951)653-4666 Report of COMPRESSIVE STRENGTH-CONCRETE ASTM C39 CITY OF CARLSBAD-BLDG INSPECTION DEPT 1635 FARADAY AVENUE CARLSBAD, CA 92008 Client LNR PROPERTY CORPORATION Set No 8-01023 File No N/A Permit No N/A Project No 1424A20 Project Name CARLSBAD. CA * Age (Days) 7 28 28 28 H Date Tested 4/30/2008 5/21/2008 5/21/2008 5/21/2008 Nominal Size 6X 12 6X 12 6X 12 6X 12 Actual Area (Sq Inch) 2827 2827 2827 2827 Load (Ibs) 116,900 Strength (psi) 4,130 Type of Fracture Shear Specified Strength 3,000 PSI_Sampled By QUYNH VUONG LocaUoTT'BlTSHOp'MAJOR C=E Concrete Supplier SUPERIOR READY MIX Mix No 8375P Ticket No Water added at Site gal By Cement Type II/V Mix Time 56 mm ASTMC172 Date Sampled 4/23/2008 Date Received 4/24/2008 Concrete Temp 65 Ambient Temp °F ASTM C1064 "F ASTM C1064 Slump 400 in ASTM C143 Tested at San Diego Remarks Distribution LNR PROPERTY CORPORATION CITY OF CARLSBAD-BLDG INSPECTION DEPT **LAB COPY** Respectfully Submitted, MTGL, Inc Eduardo Dizon, R C E OJ Insulation, LP - Escondido (874) 2061 Aldergrove Ave Escondido, CA 92029 7 ~ Insulation Certificate Insulation is installed in the structure described below as follows Work Area Attic Area - Wire Demising Walls Sound walls Exterior Walls and Rim Joists Attic Area - Batts Attic Area - Batts *Fiberglass blow has no settling factor for R-values Job Name. BRESSI RANCH VILLAGE CENTER Lot No Shop D Item Installed ISW17G Wire 17 Gauge 1/4 MI Spool R-ll 16" x 96" - Unfaced - CertaSound - Batts R-ll 24" x 96" - Unfaced - CertaSound - Batts R-19 15 25" x 48" - Unfaced - Batts R-30 16" x 48" - Unfaced - Batts R-30 24" x 48" - Unfaced - Bans Job Address EL FUERTE AND GATEWAY STREET CARLSBAD, CA 92008 Sq Feet 8,400 3,550 500 4,800 8,400 8,400 Date Completed: October 14, 2008 Insulation By: THE CITY OF SAN DIEGO DEVELOPMENT SERVICES DEPARTMENTDIVISION OF BUILDING S SAFETY - INSPECTION SERVICES Tel. (858) 492-5070 Fax m8) 4920053 SPECIAL INSPECTOR ID CARD Name: _CRAIG_BJCHTEL Certificate N Signature^ Expiration: Oecem|(fer 31,2010 SEE REVERSE SIDE FORTYPEK) OF WORK AUTHORIZED Ft..,. IK CRAIG A BECHTEL REINFORCED CONCRETE SPECIAL INSPECTOR The individual named hereon is CERTIFIED in the category shown, having been so certified pursuant to successful completion of the prescribed written examination and ACi requirements. Expiration date: October No. Not/illd unless signed by certificate holder. ICC cmifkcstiaa attests to competent knowledge of cote and statdools.