City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No: CB110744
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
Project Title:
2659 GATEWAY RD CBAD St: 106
Tl Sub Type:
2131912500 Lot#:
$74,685.44 Construction Type:
Reference #:
THE BAR METHOD: SHELL TO
FITNESS FACILITY//COMBINES STE
COMM
0
NEW
Applicant:
LNR CPI BRESSI RETAIL L L C
C/O LNR PROPERTY CORP
4350 VON KARMAN AVE #200
NEWPORT BEACH CA 92660
Status:
Applied:
Entered By:
Plan Approved:
105&1062.012SF Issued:
Inspect Area:
Plan Check#:
Owner:
LNR (DPI BRESSI RETAIL L L C
C/O f NR PROPERTY CORP
4350 VON KARMAN AVE #200
NEWPORT BEACH CA 92660
ISSUED
04/08/2011
JMA
05/26/2011
05/26/2011
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'l Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB1473) Fee 1
Fire Expedited Plan Review
$532.18
$0.00
$345.92
$0.00
$0.00
$15.68
$0.00
$0.00
$0.00
$0.00
$0.00
i $0.00
$0.00
r $0.00
$0.00
$0.00
$0.00
: $1 .00
$587.50
Meter Size
Add'l Reel. Water Con. Fee
Meter Fee
SDCWA Fee
CFD Payoff Fee
PFF (31 05540)
PFF (4305540)
License Tax (31 041 93)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541 )
PLUMBING TOTAL
ELECTRICAL f OTAL
MECHANICAL TOTAL
Master Drainage Fee
Sewer Fee
Redev Parking Fee
Additional Fees
HMP Fee
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$62.00
$20.00
$24.00
$0.00
$0.00
$0.00
$0.00
??
TOTAL PERMIT FEES $1,588.28
Total Fees:$1,588.28 Total Payments To Date:$1,588.28 Balance Due:$0.00
Inspector:
FINAL APPROVAL
Date: &///(/Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as lees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has oreviouslv otherwise expired.
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
760-602-2717/2718/2719
Fax 760-602-8558
www.cartsbadca.gov
Plan Check
Est Value
Q 7 H <-f
£ g $M
Plan Ck. Deposit
Date SWPPP
JOB ADDRESS,ifr
# OF UNITS I # BEDROOMS
SUITOt//UNIT# |Afj MX I"^ I TENANT BUSINESS NAMECT/PROJECT »# BATHROOMS CONSTR. TYPE OCC. GROUP
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s.
To
EXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE
YES[~~|#
AIR CONDITIONING FIRE SPRINKLERS
CONTACT NAME amHetanffon&raMcant)ICANTNAME
ADDRESS ADDRESS
CITY STATE ZIP CITY STATE
PROPERTY OWNER NAME CONTRACTOR BUS. NAME
ADDRESS ADDRESS O.
CITY CITY ZIP
PHONE PHONE FAX
EMAIL EMAIL
ARCH/DESIGNER NAME & ADDRESS CnYBUS.LIC.#
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires theapplicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to acivil penally of not more than five hundred dollars ($500)).
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
LJI have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
- yExTnave and will maintain worKarSfCanD|agaU8US required bisection 3700 of the Labor Code, for the performance of the work for which this permit Is issued. My workers' compensation insurance carrier and policy
~" *~ " " Expiration Date
Ihisseclion need not be completed if the permit is for one hundred dollars ($100) or less.
of Exemption: I certify that in flie performance of the work for whfch 8iis permit is issued, I snail not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
number are: Insurance^Policy No..
California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100.000), in
addition to the cost of compensation, damages as provided for in
JSS CONTRACTOR SIGNATURE
or code, interest and attorney's fees.
/ hereoy affirm that I am exempt from Contractor's L/cense Lax tor the following reason:
[~~[ I, as owner of (ne property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered (or safe (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
|"| I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
properly who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law).
I am exempt under Section _Jusiness and Professions Code for this reason:
1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement l~~lYes I IMP
2. i (have / have not) signed an application for a building permit for the proposed work.
3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number):
4. l plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name /address / phone / contractors' license number):
5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name /address / phone / type of work):
Is the'applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? |" I Yes I iNo
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or ajrouality management district? L—JYes I I NoIsthefacilitytobeconstructedwithin1,000feetoftheouterboundaryofaschoolsite? I |Yes lINo
IF ANY OF THE ANSWERS ARE YES,/
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name Lender's Address
I hereby authorize representative of the City of Carlsbad to enter upon the above menfor^projx^ for inspect rjurpo^
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHft An OSHA permit is required for excavations over 5'0' deep and oterrrtirjn or ocflstructicincifsfnJCluresoverSstxiries in height
EXPIRATION: E
City of Carlsbad Bldg Inspection Request
For: 07/29/2011
Permit* CB110744
Title: THE BAR METHOD: SHELL TO
Description: FITNESS FACILITY//COMBINES STE. 105 & 106 2,012 SF
Inspector Assignment: TP
2659 GATEWAY RD
106 Lot:
Type:TI Sub Type: COMM
Job Address:
Suite:
Location:
CONTACT DEREK D. BERG
Owner:
Remarks:
Phone: 6199978777
Inspector:
Total Time:
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Requested By: DEREK
Entered By: CHRISTINE
Act Comments
Comments/Notices/Holds
Associated PCRs/CVs/SWPPPs Original PC#
Date
07/28/201 1
07/19/2011
07/19/2011
07/19/2011
07/19/2011
07/06/2011
06/30/201 1
06/27/201 1
06/22/2011
06/22/201 1
06/21/2011
06/21/2011
06/06/201 1
Inspection History
Description
308 Final
14 Frame/Steel/Bolting/Welding
24 Rough/Topout
34 Rough Electric
44 Rough/Ducts/Dampers
84 Rough Combo
27 Shower Pan/Roman Tubs
17 Interior Lath/Drywall
14 Frame/Steel/Bolting/Welding
34 Rough Electric
14 Frame/Steel/Bolting/Welding
24 Rough/Topout
21 Underground/Under Floor
Act
Fl
AP
AP
AP
AP
CO
AP
AP
AP
AP
CO
AP
PI
Insp
DF
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
Comments
T-CLNG GRID
CLNG LITES
DUCTS
SEISMIC CLIPS MISSING
WALLS
NO APPROVED PLANS ON SITE, CK WATER TEST WASTE
EsGil Corporation
In (Partners/Up with government for (Building Safety
DATE: 5/20/11
JURISDICTION: City of Carlsbad CTPCAN REVIEWER
FILE
PLAN CHECK NO.: 11-0744 SET: III •
PROJECT ADDRESS: 2659 Gateway Rd Suites 105 & 106
PROJECT NAME: The Bar Method - TI
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes. .
XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified in the remarks below are resolved and checked by building
department staff.
The plans transmitted herewith have significant deficienciesjdentified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
2<] Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by; ) Email: Fax #:
Mail Telephone Fax In Person
EMARKS: All sheets of the plans must be signed by the person responsible to their
preparation.
By: Doug Moody Enclosures:
EsGil Corporation
D GA D EJ D PC 5/16/11
9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560-1576
EsGil Corporation
In (Partnership -u/itfi government for (Buiftfing Safety
DATE: 5/12/11 Q^AEELJCANT
JURISDICTION: City of Carlsbad TTPTAN REVIEWER
a FILE
PLAN CHECK NO.: 11-0744 SET: II
PROJECT ADDRESS: 2659 Gateway Rd Suites 105 & 106
PROJECT NAME: The Bar Method - TI
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
MA Design & Drafting Services / Derek Berg
2180 Chablis Ct Suite 109, Escondido, CA 92029
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
XI Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Derek Berg Telephone #: 760-390-0007
Date contacted.^ffijil §ffir0) Email: madesign@vmail.com Fax #:
^WlaiK Telephone Fax«. In Person
REMARKS: MA^fcf >/
By:. Doug Moody Enclosures:
EsGil Corporation
D GA D EJ D PC 5/9/11
9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (858) 560-1468 * Fax (858) 560-1576
City of Carlsbad 11-0744
5/12/11
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
These corrections are in response to items not fully addressed or as the
result of information provided, the text in bold print indicates the
unresolved issue.
1. Each sheet of the plans must be signed by the person responsible for their
preparation, even though there are no structural changes. Business and
Professions Code. The plans are still not signed.
12. Show that passageways leading to sanitary facilities have required clear access
widths, per Section 1115B.5. Show that all doorways have:
a) >32" clear opening.
b) A clear area:
i) >60" in the direction of the door swing. The required door
clearance on the push side of the door is a minimum of 44"
please revise the plans for the women's restroom.
c) All strike edge clearance dimensions are required to be met (i.e. 18" strike
edge distance).
15. Show that the water closet is located in a space, per Section 1115B.3.2.3, which
provides:
a) A minimum side clearance of either:
b) A clear space in front of the water closet measuring 60" wide by 48" in front.
Section 1115B.4.1.2. A minimum of 48"x60" is required with the door
not to encroach into the required clear floors space. Please revise the
men's restroom.
•City of Carlsbad 11-0744
5/12/11
16. Doors shall not swing into the clear floor space required for any fixture but may
swing into that portion of the maneuvering space which does not overlap the
required clear floor space. Maintain the required clearances at the lavatory/water
closet without the entry door swinging into those areas. Section 1115B.3.2.2. The
men's restroom does not comply. Please correct the plans.
17. If showers are proposed, show or note compliance with the following requirements,
per Section 1115B.4.4:
a) Size and Clearance. Accessible showers shall comply with one of the
following:
i) Roll-in shower 60 inches minimum in width between wall surfaces
and 30 inches in depth with a full opening width on the long side.
Shower compartment size and clear floor space shall comply with
Figure 11B-2A. The plans show the wrong size shower, please
correct the plans.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes a No Q
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Doug Moody at
Esgil Corporation. Thank you.
EsGil Corporation
In Partnership witH government for (Buififing Safety
DATE: 4/19/11 a APPLICANT
JURISDICTION: City of Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO.: 11-O744 SET: I
PROJECT ADDRESS: 2659 Gateway Rd Suites 105 & 106
PROJECT NAME: The Bar Method - TI
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
X] The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
XI The applicant's copy of the check list has been sent to:
MA Design & Drafting Services /Derek Berg
2180 Chablis Ct Suite 109, Escondido, CA 92029
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Derek Berg (w-M) Telephone #: 760-390-0007
Date contacted: v!?0'h (by: j^2 ) Email: madesigning@gmail.com Fax #:
t Mail-^ Telephone <s Fax In Person
REMARKS:
By: Doug Moody Enclosures:
EsGil Corporation
D GA D EJ D PC 4/12/11
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 •* Fax (858) 560-1576
City of Carlsbad 11-0744
4/19/11
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 11-0744
OCCUPANCY: B
TYPE OF CONSTRUCTION: VB
ALLOWABLE FLOOR AREA:
SPRINKLERS?: Yes
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 4/8/11
DATE INITIAL PLAN REVIEW
COMPLETED: 4/19/11
JURISDICTION: City of Carlsbad
USE: Gymnasium
ACTUAL AREA: 2012sf
STORIES: 1
HEIGHT:
OCCUPANT LOAD: 45
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 4/12/11
PLAN REVIEWER: Doug Moody
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and access for the disabled. This plan
review is based on regulations enforced by the Building Department. You may have other
corrections based on laws and ordinances enforced by the Planning Department, Engineering
Department, Fire Department or other departments. Clearance from those departments may be
required prior to the issuance of a building permit.
Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2009 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e.. plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
City of Carlsbad 11-0744
4/19/11
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
1. Each sheet of the plans must be signed by the person responsible for their
preparation, even though there are no structural changes. Business and
Professions Code.
2. Please provide a statement on the Title Sheet of the plans to show compliance
with the current Codes. The following are the correct current Codes:
a) The 2010 edition of the California Building Code (CBC) adopts the 2009
International Building Code (IBC) and the 2010 California Amendments.
b) The 2010 edition of the California Electrical Code (CEC) adopts the 2005
National Electrical Code (NEC) and the 2008 California Amendments.
c) The 2010 edition of the California Mechanical Code (CMC) adopts the
2006 Uniform Mechanical Code (UMC) and the 2009 California
Amendments.
d) The 2010 edition of the California Plumbing Code (CPC) adopts the 2006
Uniform Plumbing Code (UPC) and the 2009 California Amendments.
e) The 2010 edition of the California Fire Code (CFC) adopts the 2009
Uniform Fire Code (UFC) and the 2007 California Amendments.
f) The 2008 edition of the California Energy Efficiency Standards.
3. Provide a Building Code Data Legend on the Title Sheet. Include the following
code information for each building proposed:
• Occupancy Classification(s) a "B" occupancy.
• Occupant Load based on 1 occupant per 50 sf in the studio and 1 per
100 sf all other areas.
4. A tactile sign stating "EXIT" and complying with ICC A117.1 shall be provided
adjacent to each door to an egress stairway, an exit passageway and the exit
discharge. Section 1011.3.
City of Carlsbad 11-O744
4/19/11
5. Please provide notes on the plans to show the suspended ceilings in Seismic
Design Categories D, E & F comply with ASCE 7-05 Section 13.5.6.2.1 as
follows:
a) All ceilings shall use a Heavy Duty T-bar grid system.
b) The width of the perimeter supporting closure angle shall be not less than
2 inches.
c) In each orthogonal horizontal direction, one end of the ceiling grid shall be
attached to the closure angle.
d) The other end in each horizontal direction shall have a %" clearance from
the wall and shall rest upon and be free to slide on a closure angle or a
listed assembly.
e) Ceiling areas over 1,000 ft.2 must have horizontal restraint wires (typically
restraint would consist of four 12 gauge wires splayed 90° to each other
and sloped 45° to the horizontal, spaced 12" o.c.).
f) Ceilings without rigid bracing must have 2" oversize trim rings for
sprinklers and other ceiling penetrations.
6. Please note in the general wiring notes on the plans "AC Cable is not allowed in
A, B, E, H, F, M, S and I occupancies. NM cable is restricted (without City
approval) to one and two family dwellings. Note on plans that an equipment
ground conductor is to be installed in all flexible conduits".
7. Please have the principle designer check the appropriate box(s) and complete
the Statement of Compliance System Acceptance section of the LTG-1-C part 4
of 4 documents.
8. Provide separate restroom facilities for each sex as per UPC, Section 412.1.
9. Hot water supplied to a public use lavatory is limited to a maximum temperature
potential of 120 degrees by a device that conforms to ASSE 1070 or CSA
B125.3; please provide the manufacturer's listing showing compliance. Detail
how this temperature limitation is achieved. The water heater thermostat may not
be used for compliance with this Code section. UPC 413.1 & UPC 414.
10. Provide the following information concerning the water heater:
• Provide combustion air design: Show opening sizes and routing of ducts.
UPC 507.0
• Detail the water heater vent installation: Size, routing, slope, and termination
location (Minimum 8' from vertical surfaces). UPC 510.0.
Note : When alterations, structural repairs or modifications or additions are made to an
existing building, that building, or portion of the building affected, is required to comply
with all of the requirements for new buildings, per Section 1134B.2. These requirements
apply as follows:
City of Carlsbad 11-0744
4/19/11
a) The area of specific alteration, repair or addition must comply as "new"
construction.
b) A primary entrance to the building and the primary path of travel to the
altered area, must be shown to comply with all accessibility features.
c) Existing sanitary facilities that serve the remodeled area must be shown to
comply with all accessibility features.
11. Please revise the men's / women's restrooms to be fully disabled accessible.
12. Show that passageways leading to sanitary facilities have required clear access
widths, per Section 1115B.5. Show that all doorways have:
a) >32" clear opening.
b) A clear area:
i) >60" in the direction of the door swing.
c) All strike edge clearance dimensions are required to be met (i.e. 18" strike
edge distance).
13. Note that the doorways leading to sanitary facilities shall be identified, per Section
1115B.6, as follows:
a) An equilateral triangle W thick with edges 12" long and a vortex pointing
upward at men's rest rooms.
b) A circle YA" thick, 12" in diameter at women's rest rooms.
c) A 12" diameter circle with a triangle superimposed on the circle and within
the 12" diameter at unisex rest rooms.
d) The required symbols shall be centered on the door at a height of 60".
e) Braille signage shall also be located on the wall adjacent to the latch
outside of the doorways leading to the sanitary facilities, per Section
1117B.5.1.
14. Show a sufficient space in the toilet room for a wheelchair to enter the room and
close the door, per Section 1115B.3.2. The space is required to be:
a) >60" diameter.
b) A T-shaped space as shown in Figure 11 B-12(a) and (b).
c) Doors are not permitted to encroach into this space by more than 12
inches.
15. Show that the water closet is located in a space, per Section 1115B.3.2.3, which
provides:
a) A minimum side clearance of either:
City of Carlsbad 11-0744
4/19/11
i) >28" from a fixture. This clearance shall extend all the way to the
rear wall. Section 1115B.4.1.1. This will generally require the toilet
room to be 7' wide (along the rear wall) by 6-6" in the other direction.
ii) >32" from a wall on one side. This clearance shall extend all the way
to the rear wall.
b) A clear space in front of the water closet measuring 60" wide by 48" in front.
Section 1115B.4.1.2.
16. Doors shall not swing into the clear floor space required for any fixture but may
swing into that portion of the maneuvering space which does not overlap the
required clear floor space. Maintain the required clearances at the lavatory/water
closet without the entry door swinging into those areas. Section 1115B.3.2.2.
17. Show that accessible lavatories comply with the following, per Sections 1115B.4.3:
a) >30" x 48" clear space is provided in front for forward approach. The clear
space may include knee and toe space beneath the fixture.
b) When lavatories are adjacent to a side wall or partition, there shall be a
minimum of 18" to the center line of the fixture to the wall.
c) The counter top is £34" maximum above the floor.
d) >29" high, reducing to 27" at a point located 8" back from the front edge.
e) >9" high x 30" wide and 17" deep at the bottom.
f) Hot water pipes and drain lines are insulated.
18. Show that grab bars comply with the following, per Section 1115B.4:
a) Grab bars shall be located on each side or one side and the back of the
water closet stall or compartment.
b) They shall be securely attached 33" above the floor, and parallel.
NOTE: Where a tank-type toilet is used which obstructs placement at 33", the grab
bar may be installed as high as 36".
c) Grab bars at the side shall be located:
i) 15" to 16>2" (±1") from the center line of the water closet stool,
ii) Be >42" long with the front end positioned 24" in front of the stool,
iii) Total length of bars at the back shall be >36".
d) The diameter, or width, of the grab bar gripping surface is >1%" but <11/2n,
or the shape shall provide an equivalent gripping surface.
e) If mounted adjacent to a wall, the space between the wall and the grab bar
shall be 11/2".
19. If showers are proposed, show or note compliance with the following requirements,
per Section 1115B.4.4:
City of Carlsbad 11-O744
4/19/11
a) Size and Clearance. Accessible showers shall comply with one of the
following:
i) Roll-in shower 60 inches minimum in width between wall surfaces
and 30 inches in depth with a full opening width on the long side.
Shower compartment size and clear floor space shall comply with
Figure 11B-2A.
ii) Alternate roll-in shower 60 inches minimum in width between the wall
surfaces and 36 inches in depth with an entrance opening width of
36 inches minimum. Shower compartment size and clear floor space
shall comply with Figure 11B-2B.
iii) Alternate roll-in shower 60 inches minimum in width between the wall
surfaces and 36 inches in depth as long as the entrance opening
width is a minimum of 36 inches. Shower compartment size and
clear floor space shall comply with Figure 11B-2C.
b) Threshold in roll-in type showers shall be 1/4 inch in high maximum and shall
comply with Section 1124B.2.
c) Orientation. Where within the same functional area/two or more accessible
showers are provided, there shall be at least one shower constructed
opposite hand from the other or others (i.e., one left-hand control versus
right-hand control).
d) Water controls shall be of a single-lever design, operable with one hand,
and shall not require grasping, pinching or twisting of the wrist. The center
line of the controls shall be located at 40 inches above the shower floor.'
i) Controls in a 60-inch minimum by 30-inch minimum shall be located
on the back wall of the compartment adjacent to the seat and the
centerline of the controls shall be within a range of no less than 19
inches and no more than 27 inches from the seat wall as shown in
Figure 11B-2A.
ii) Controls in a 60-inch minimum by 36-inch minimum alternate roll-in
shower shall be located on the side wall of the compartment
adjacent to the seat and the centerline of the controls shall be within
a range of no less than 19 inches and no more than 27 inches from
the seat wall as shown in Figure 11B-2B.
iii) Controls in a 60-inch minimum by 36-inch minimum alternate roll-in
shower with optional enclosure shall be located on the back wall of
the compartment adjacent to the seat and the centerline of the
controls shall be within a range of no less than 19 inches and no
more than 27 inches from the seat wall as shown in Figure 11B-2C.
e) A flexible hand-held shower unit is required with at least a hose 60 inches
long that can be both used as a fixed shower head and hand held. This unit
shall be mounted such that the top of the mounting bracket is a maximum
of 48 inches above the shower floor.
City of Carlsbad 11-0744
4/19/11
i) The hand held sprayer unit a 60-inch minimum by 30-inch minimum
shall be located on the back wall of the compartment adjacent to the
seat and the centerline of the controls shall be within a range of no
less than 19 inches and no more than 27 inches from the seat wall
as shown in Figure 1.1 B-2A
ii) The hand held sprayer unit in a 60-inch minimum by 36-inch
minimum alternate roll-in shower shall be located on the side wall of
the compartment adjacent to the seat and the centerline of the
controls shall be within a range of no less than 19 inches and no
more than 27 inches from the seat wall as shown in Figure 11B-2B.
iii) The hand held sprayer unit in a 60-inch minimum by 36-inch
minimum alternate roll-in shower with optional enclosure shall be
located on the back wall of the compartment adjacent to the seat
and the centerline of the controls shall be within a range of no less
than 19 inches and no more than 27 inches from the seat wall as
shown in Figure 11B-2C.
f) Two wall-mounted heads may be installed in lieu of the hand-held unit in
areas subject to excessive vandalism. (Except within guest room and suites
of hotels, motels and similar transient lodging establishments) Each shower
head shall be installed so that it can be operated independently of the other
and shall have swivel angle adjustments both vertically and horizontally.
One head shall be located at a height of 48 inches above the floor.
g) The floor slope shall be a maximum of 2% in any direction. Where drains
are provided, the grate shall have openings % inch maximum and located
flush with the floor surface.
h) Indicate on the plans a folding seat, located on the wall adjacent to the
controls, 18" above the floor and shall not extend more than 6 inches from
the wall. The seat dimensions and mounting position shall comply with
Figures 11B-2A, 11B-2B, 11B-2C.
i) Grab bars complying with Section 1115B.4.4.8 shall be located:
i) On walls adjacent to and opposite the seat,
ii) Mounted >33" but <36" above the shower floor.
iii) Grab bars shall not extend into that portion of the wall over the seat.
See Figures 11B-2A, 11B-2B, 11B-2C
j) The soap dish when provided shall be located on the control wall £40"
above the shower floor and within reach limits from the seat. Section
1115B.4.4.9.
k) Enclosures when provided for shower compartments shall not obstruct
controls or obstruct transfer from wheelchairs onto the shower seat.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
City of Carlsbad 11-0744
4/19/11
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes Q No a
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Doug Moody at
Esgil Corporation. Thank you.
City of Carlsbad 11-O744
4/19/11
[DO NOT PAY-THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad PLAN CHECK NO.: 11-0744
PREPARED BY: Doug Moody DATE: 4/19/11
BUILDING ADDRESS: 2659 Gateway Rd Suites 105 & 106
BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VB
BUILDING II AREA
PORTION ( Sq. Ft.)
Tl
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
2012
cb
Valuation
Multiplier
34.37
By Ordinance
Reg.
Mod.
VALUE ($)
69,152
69,152
Bldg. Permit Fee by Ordinance
Plan Check Fee by Ordinance
Type of Review:
I I Repetitive FeeRepeats
Complete Review
D Other
r—| Hourly
EsGil Fee
Structural Only
Hr. @ *
$509.43
$331.13
$285.28
Comments:
Sheet 1 of 1
macvalue.doc +
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER DATE
ADDRESS
RESIDENTIAL (TENANT IMPROVEMENT/^
^•^s^^ ^—^-"^^^""^^^
RESIDENTIAL ADDITION MINOR
(<$17,000.00)
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER
PLANNER DATE
ENGINEE1 DATE
Q:\f DEng\D«ve(opm«K Sftvicw<CarreipandMC«Ontiv«a«\tar plmhMkingUUILOING PtANCHECK CKLIST FORM - PUNNING ENGINERING
APPROVALS.docx
T
00
3t 3t
JXl Jcfo o0) (1)
o o
D D
a a
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CB11-0744 Address 2659 Gateway Rd
Planner Chris Sexton Phone (760) 602-4624
APN:
Type of Project & Use: JJ. Net Project Density:N/A DU/AC
Zoning: P-C General Plan: RH/L/CF Facilities Management Zone: 17
CFD (in/out) #_Date of participation: Remaining net dev acres:.
Circle One (For non-residential development: Type of land used created by this permit:
Legend: Kl Item Complete
Environmental Review Required:
DATE OF COMPLETION:
:em Incomplete - Needs your action
YES D NO D TYPE
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required: YES Q NO D TYPE
APPROVAL/RESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES Q NO Q
CA Coastal Commission Authority? YES Q NO EH
If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103,
San Diego, CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
Habitat Management Plan
Data Entry Completed? YES D NO D
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and
assess fees in Permits Plus
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type
impacted/taken, UPDATE!)
Inclusionary Housing Fee required: YES Q NO Q
(Effective date of Inclusionary Housing Ordinance - May 21, 1993.)
Data Entry Completed? YES D NO D
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N,
Enter Fee, UPDATE!)
H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev 4/08
Site Plan:E n p Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements,
existing and proposed structures, streets, existing street improvements, right-of-way width,
dimensional setbacks and existing topographical lines (including all side and rear yard slopes).
Provide legal description of property and assessor's parcel number.
Policy 44 - Neighborhood Architectural Design Guidelines
DD 1. Applicability: YES D NO D
D D 2. Project complies: YES D NOJH
D
DD
Zoning:
1. Setbacks:
Front:
Interior Side:
Street Side:
Rear:
Top of slope:
Required
Required
Required
Required
Required
DD
2. Accessory structure setbacks:
Front: Required.
Interior Side: Required
Street Side: Required
Rear: Required
Structure separation: Required
3. Lot Coverage: Required
Shown
Shown
Shown
Shown
Shown
Shown
Shown.
Shown
Shown.
Shown.
Shown
D 4. Height:Required Shown
D Spaces Required Shown5. Parking:
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required Shown
Additional Comments 1) Please take off signage on sheet A2. 2) How will the new roof mounted
HVAC equipment be screened? Please see handout. •-"*)-ll-ll per"
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER
H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev 4/08
Carlsbad Fire Department
Plan Review Requirements Category: TI, COMM
Date of Report: 05-25-2011 Reviewed by:
Name:
Address:
LNR CPIBRESSI RETAIL L L C
C/O LNR PROPERTY CORP
4350 VON KARMAN AVE #200
NEWPORT BEACH CA
92660
Permit #: CB110744
Job Name: THE BAR METHOD: SHELL TO
Job Address: 2659 GATEWAY RD CBAD St: 106
!o^xxMyd!(YXYyxxyy_yyxxyyyxxxxxxyxxxxxxxxxxxy.yxxyxxxxxxxxxxxxxyy"X
wwx/wwvwwwwwx/wwvwwwwww
Conditions;
Cond: CON0004647
[MET]
** CITY OF CA KLSBAD FIRE DEPARTMENT - APPROVED:
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF
BUILDING PERMIT.
THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON
CONDITIONS IN '
CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS.
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW.
Entry: 05/25/2Oil By: GR Action: AP ASSEMBLY OCCUPANCY PERMIT REQUIRED
SAN DIEGO REGIONAL
HAZARDOUS MATERIALS QUESTIONNAIRE
OFFICE USE ONLY
UPFP#___
HW
BP DATE
Business N Business Contact Telephone*
Project City State
G4
Zip Code APN#
cr te Zip Code Plan File*
r"*aMa Tel
)
The following questions represent the facility's activities, NOT the specific project description.
PART I: FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business
will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with
jurisdiction prior to plan submittal.
5. Organic Peroxides 9. Water Reactives 13. Corrosives
6. Oxidizers 10. Cryogenics 14. Other Health Hazards
7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These.
8. Unstable Reactives 12. Radioactives
1. Explosive or Blasting Agents
2. Compressed Gases
3. Flammable/Combustible Liquids
4. Flammable Solids
PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD): If
questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 1255 Imperial Avenue, 3 floor, San Dieg
Call (61 9) 338-2222 prior to the issuance of a building permit.
FEES ARE REQUIRED. Expected Date of Occupancy: / /
YES NO
1 . O &~~ Is your business listed on the reverse side of this form? (check all that apply).
2. D /S Will your business dispose of Hazardous Substances or Medical Waste in any amount?
3. D "53 Will your business store or handle Hazardous Substances in quantities equal to or greater than
55 gallons, 500 pounds, 200 cubic feet, or carcinogens/reproductive toxins in any quantity?
4. D <2f Will your business use an existing or install an underground storage tank?
5. D 00 Will your business store or handle Regulated Substances (CalARP)?
6. D EKvWill your business use or install a Hazardous Waste Tank System (Title 22, Article 1 0)?
the answer to any of the
o, CA92101.
D CalARP Exempt
/
Date Initials
D CalARP Required
/
Date Initials
D CalARP Complete
/
Date Initials
PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air
Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition
permit. Note: if the answer to questions 3 or 4 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to
commencing demolition or renovation, except demolition or renovation of residential structures of four units or less. Contact the APCD for more information.
1 •
YES
D
3.
4.
D
D
Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the
APCD factsheet at http://www.sdapcd.org/info/facts/permits.pdf. and the list of typical equipment requiring an APCD permit on the reverse side
of this from. Contact APCD if you have any questions).
(ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1 ,000 feet of the outer boundary of a school (K through 1 2)?
(Public and private schools may be found after search of the California School Directory at http://www.cde.ca.gov/re/sd/: or contact the
appropriate school district).
WH there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos?
Will there be demolition involving the removal of a load supporting structural member?
Briefly describe business activities:Briefly describe proposed project:
alty of perju
Name of owner or Authorized Agent
to the best of my knowledge and belief the responses mad
sigi
correct.
Date -ili
FOR OFFICIAL USE ONLY:FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:.
BY: .DATE:
EXEMPT OR NO FURTHER INFORMATION REQUIRED
COUNTY-HMD APCD
RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY
COUNTY-HMD APCD
RELEASED FOR OCCUPANCY
COUNTY-HMD APCD
HM-9171 (04/07)County of San Diego - DEH - Hazardous Materials Division
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
The Bar Method
Bressi Ranch Shop "D"
Carlsbad , CA
Project Designer:
MA Design & Drafting Services
135 W Mission Ave Suite 109
Escondido, CA 92025
760 390 0007
Report Prepared by:
Rocky Salehi
Salehi Engineering, Inc.
3680 Clairmont Mesa Blvd Suite 111
San Diego,, CA92111
858-277-5551
Job Number:
Z-306
Date:
4/4/2011
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 5.1 by EnergySoft User Number: 1233 Run Code: 2011-04-04712:03:51 ID: Z-306
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form MECH-1-C Certificate of Compliance 3
Form MECH-2-C Air & Water System Requirements 7
Form MECH-3-C Mechanical Ventilation 9
Form MECH-4-C HVAC Misc. Prescriptive Requirements 10
Form MECH-MM Mechanical Mandatory Measures 12
EnergyPro 5.1 by EnergySoft job Number: ID: Z-306 User Number: 1233
CERTIFICATE OF COMPLIANCE and (Part 1 of 5) MECH-1 C
FIELD INSPECTION ENERGY CHECKLIST
Project Name Date
The Bar Method 4/4/201 1
Project Address Climate Zone Total Cond. Floor Area Addition Floor Area
Bressi Ranch Shop "D" Carlsbad 7 2,012 n/a
GENERAL INFORMATION
Building Type: Q Nonresidential D High-Rise Residential D Hotel/Motel Guest Room
D Schools (Public School) D Relocatable Public School Bldg. 0 Conditioned Spaces D (^fdavi't)10"6'1 SpaC6S
Phase of Construction: D New Construction D Addition D Alteration
Approach of Compliance: D Component D Overall Envelope TDV n Unconditi0ned (file affidavit)
Front Orientation: N, E, S, W or in Degrees: o deg
HVAC SYSTEM DETAILS
Equipment2
Item or System Tags
(i.e. AC-1,RTU-1,HP-1)
Equipment Type3:
Number of Systems
Max Allowed Heating Capacity1
Minimum Heating Efficiency1
Max Allowed Cooling Capacity1
Cooling Efficiency1
Duct Location/ R-Value
When duct testing is required, submit
MECH-4A & MECH-4-HERS
Economizer
Thermostat
Fan Control
Equipment2
Item or System Tags
(i.e. AC-1,RTU-1,HP-1)
Equipment Type3:
Number of Systems
Max Allowed Heating Capacity1
Minimum Heating Efficiency1
Max Allowed Cooling Capacity1
Cooling Efficiency1
Duct Location/ R-Value
When duct testing is required, submit
MECH-4A & MECH-4-HERS
Economizer
Thermostat
Fan Control
Inspection Criteria
DHW Heater
Gas Fired DHW Boiler
1
40,000 Btu/hr
0.53 EF
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Inspection Criteria
(E) HP-D6
Packaged DX
1
29,246 Btu/hr
8.00HSPF
48,065 Btu/hr
13.0 SEER/ 11. OEER
R-4.2
No
Fixed Temp (Integrated)
Setback Required
Constant Volume
FIELD INSPECTION ENERGY CHECKLIST
Meets Criteria or Requirements
Pass
D
D
D
D
a
a
a
a
D
D
n
D
Fail - Describe Reason2
D
D
D
D
D
D
D
D
D
D
D
D
FIELD INSPECTION ENERGY CHECKLIST
Pass
D
D
D
D
D
D
D
D
D
D
D
D
Fail - Describe Reason2
D
D
D
D
D
D
D
D
D
D
D
D
1 . If the Actual installed equipment performance efficiency and capacity is less than the Proposed (from the energy compliance submittal or from
the building plans) the responsible party shall resubmit energy compliance to include the new changes.
2. For additional detailed discrepancy use Page 2 of the Inspection Checklist Form. Compliance fails if a Fail box is checked.
3. Indicate Equipment Type: Gas (Pkg or, Split), VAV, HP (Pkg or split), Hydronic, PTAC, or other.
EnergyPro 5. 1 by EnergySoft User Number: 1233 Run Code: 2011-04-04T12:03:51 ID: Z-306 Page 3 of 12
CERTIFICATE OF COMPLIANCE and (Part 1 of 5) MECH-1 C
FIELD INSPECTION ENERGY CHECKLIST
Project Name Date
The Bar Method 4/4/201 1
Project
Bress
GENE
Buildin
D Sc
Phase
Approj
Front C
HVA(
Equip
Item o
(i.e. AC
Equipn
Numbe
Max A
Minimi
Max A
Coolin
DuctL
When
MECH
Econo
Therm
FanCc
Equipi
Item oi
(i.e. AC
Equipn
Numtx
Max A
Minimi
Max A
Coolin
DuctL
When
MECH
Econo
Therm
FanCc
1. If the
theb
2. For a
3. Indie;
Energyi
Address Climate Zone Total Cond. Floor Area Addition Floor Area
' Ranch Shop "D" Carlsbad 7 2,012 n/a
3AL INFORMATION
g Type: ^ Nonresidential D High-Rise Residential D Hotel/Motel Guest Room
tiools (Public School) D Relocatable Public School Bldg. El Conditioned Spaces O ]^^0ned Spaces
of Construction: D New Construction D Addition D Alteration
ich of Compliance: D Component D Overall Envelope TDV n Unconditioned (file affidavit)
)rientation: N, E, S, W or in Degrees: Odeg
J SYSTEM DETAILS
nent2
System Tags
;-1,RTU-1,HP-1)
lent Type3:
\r of Systems
lowed Heatinq Capacity1
im Heatinq Efficiency1
lowed Cooling Capacity1
3 Efficiency1
jcation/ R- Value
duct testing is required, submit
4A & MECH-4-HERS
nizer
Dstat
ntrol
nent2
System Tags
;-1,RTU-1,HP-1)
lent Type3:
r of Systems
owed Heating Capacity1
m Heatinq Efficiency1
owed Cooling Capacity1
3 Efficiency1
Dcation/ R-Value
duct testing is required, submit
4A & MECH-4-HERS
nizer
Dstat
ntrol
Inspection Criteria
(E) HP-D7
Packaged DX
1
30,165Btu/hr
8.00 HSPF
52,419 Btu/hr
13.0 SEER /11.0EER
R-4.2
No
Fixed Temp (Integrated)
Setback Required
Constant Volume
Inspection Criteria
FIELD INSPECTION ENERGY CHECKLIST
Meets Criteria or Requirements
Pass
D
n
D
D
D
D
D
D
D
D
D
D
Fail - Describe Reason2
D
n
D
D
D
D
n
D
D
D
D
D
FIELD INSPECTION ENERGY CHECKLIST
Pass
n
n
a
D
D
D
D
n
D
D
D
D
Fail - Describe Reason2
D
D
D
D
D
D
D
D
D
D
D
D
Actual installed equipment performance efficiency and capacity is less than the Proposed (from the energy compliance submittal or from
jilding plans) the responsible party shall resubmit energy compliance to include the new changes,
dditional detailed discrepancy use Page 2 of the Inspection Checklist Form. Compliance fails if a Fail box is checked,
ite Equipment Type: Gas (Pkg or, Split), VAV, HP (Pkg or split), Hydronlc, PTAC, or other.
3ro 5.1 bv EnergySoft User Number: 1233 Run Code; 2011-04-04712:03:51 ID: 2-306 Page4of12
CERTIFICATE OF COMPLIANCE and
FIELD INSPECTION ENERGY CHECKLIST
(Part 2 of 5)MECH-1C
Project Name
The Bar Method
Date
4/4/2011
Discrepancies:
EnergyPro 5.1 by EnergySoft User Number: 1233 RunCode: 2011-04-04712:03:51 ID: Z-306 Page 5 of 12
CERTIFICATE OF COMPLIANCE (Part 5 of 5) MECH-1 C
Project Name
The Bar Method
Documentation Author's Declaration Statement
I certify that this Certificate of Compliance documentation is accurate and complete. _
Name ,., , „ . . . SRocky Sa/e/i/
" Salehi Engineering, Inc.
Address C3680 Clairmont Mesa Blvd Suite 111 £
City/State/Zip San Diego,, CA 921 1 1 P
The Principal Mechanical Designer's Declaration Statement
• I am eligible under Division 3 of the California Business and Professions Code tc
design.
• This Certificate of Compliance identifies the mechanical features and performam
with Title-24, Parts 1 and 6 of the California Code of Regulations.
• The design features represented on this Certificate of Compliance are consisten
this design on the other applicable compliance forms, worksheets, calculations,
enforcement agency for approval with this building permit application.
Name Salehl Engineering Inc. SignatU
Company ,.,,..,-. . , Date JtSalehi Engmeenng Inc /*
Address 836Q Clairemont Mesa Blvd Suite 1 1 1 LjeeVise
City/State/Zip SanDieg0iCA92111 Phone
Mandatory Measures
Indicate location on building plans of Note Block for Mandatory Measures
Date
4/4/201 1
.. — — ™=$Ls-£2'se>j. * — ~£U~-"
iynSEufe { * [_? — """
'ate 4/4/2011
;EA#
EPE#
h°ne 858-277-555*
> accept responsibility for the mechanical
;e specifications required for compliance
t witlrthe information provided to document
Dlan > acid specifications submitted to the
//
MfC-M
V_ S
# rftvtt/O
858-277-5551
MECHANICAL COMPLIANCE FORMS & WORKSHEETS (check box if worksheet is included)
For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the 2008 Nonresidential Manual.
Note: The Enforcement Agency may require all forms to be incorporated onto the building plans.
El MECH-1 C Certificate of Compliance. Required on plans for all submittals.
21 MECH-2C Mechanical Equipment Summary is required for all submittals.
El MECH-3C Mechanical Ventilation and Reheat is required for all submittals with mechanical ventilation.
El MECH-4C Fan Power Consumption is required for all prescriptive submittals.
EnergyPro 5. 1 by EnergySoft User Number: 1233 Run Code: 201 1-04-04712:03:51 ID: Z-306 Page 6 of 12
AIR SYSTEM REQUIREMENTS (Part 1 of 2) MECH-2C
Project Name Date
The Bar Method 4/4/20 1 1
Item or System Tags
(i.e. AC-1,RTU-1,HP-1)
Number of Systems
MANDATORY MEASURES
Heating Equipment Efficiency
Cooling Equipment Efficiency
HVAC Heat Pump Thermostat
Furnace Controls/Thermostat
Natural Ventilation
Mechanical Ventilation
VAV Minimum Position Control
Demand Control Ventilation
Time Control
Setback and Setup Control
Outdoor Damper Control
Isolation Zones
Pipe Insulation
Duct Insulation
PRESCRIPTIVE MEASURES
Calculated Design Heating Load
Proposed Heating Capacity
Calculated Design Cooling Load
Proposed Cooling Capacity
Fan Control
DP Sensor Location
Supply Pressure Reset (DDC only)
Simultaneous Heat/Cool
Economizer
Heat Air Supply Reset
Cool Air Supply Reset
Electric Resistance Heating1
Air Cooled Chiller Limitation
Duct Leakage Sealing, If Yes, a
MECH-4-A must be submitted
1 . Total installed capacity (MBtu/hr) of c
explain which exception(s) to §144(g
Indicate Air Systems Type (Central, Single Zone, Package, VAV, or etc...)
. ' - :--^i^ ":--- ^ "fe^-"^^.. •rfSiSiv- •-- ;-JJ^rii.-.-. . • .-.,,
(E) HP-D6
1
(E) HP-D7
1
Indicate Page Reference on Plans or Schedule and indicate the applicable exception(s)
T-24 Sections
112(a)
112(a)
112(b), 112(c)
112(c), 115(a)
121(b)
121(b)
121(0
121(c)
122(e)
122(e)
122(f)
122(g)
123
124
8.00 HSPF
13.0 SEER /11.0EER
Yes
n/a
Yes
226 cfm
No
No
Programmable Switch
Setback Required
Auto
n/a
R-4.2
8.00 HSPF
13.0 SEER /11.0EER
Yes
n/a
Yes
144 cfm
No
No
Programmable Switch
Setback Required
Auto
n/a
R-4.2
144(a&b)
144(a&b)
144(a&b)
144(a&b)
144(c)
144(c)
144(c)
144(d)
144(e)
144(f)
144(f)
144(g)
144(i)
144(k)
29,246 Btu/hr
25,704 Btu/hr
33, 646 Btu/hr
32,760 Btu/hr
Constant Volume
Yes
No
Fixed Temp (Integrated)
Constant Temp
Constant Temp
\
No
30,165 Btu/hr
25,704 Btu/hr
36,693 Btu/hr
35,018 Btu/hr
Constant Volume
Yes
No
Fixed Temp (Integrated)
Constant Temp
Constant Temp
No
ill electric heat on this project exclusive of electric auxiliary heat for heat pumps. If electric heat is used
) apply.
EnergyPro 5. 1 by EnergySoft User Number: 1233 RunCode: 201 1-04-04712:03:51 ID: Z-306 Page 7 of 12
WATER SIDE SYSTEM REQUIREMENTS (Part 2 of 2) MECH-2C
Project Name Date
The Bar Method 4/4/20 1 1
Item or System Tags
(i.e.AC-1,RTU-1,HP-1)1
Number of Systems
MANDATORY MEASURES
Equipment Efficiency
Pipe Insulation
PRESCRIPTIVE MEASURES
Cooling Tower Fan Controls
Cooling Tower Flow Controls
Variable Flow System Design
Chiller and Boiler Isolation
CHW and HHW Reset Controls
WLHP Isolation Valves
VSD on CHW, CW & WLHP Pumps>5HP
DP Sensor Location
1 . The proposed equipment need to mat
next to applicable section.
2. For each chiller, cooling tower, boiler,
section and paragraph number where
applicable section.
Item or System Tags
(i.e.WH-1,WHP, DHW, etc...)1
Number of Systems
MANDATORY MEASURES
SERVICE HOT WATER
Certified Water Heater
Water Heater Efficiency
Service Water Heating Installation
Pipe Insulation
POOL AND SPA
Pool and Spa Efficiency and Control
Pool and Spa Installation
Pool Heater -No Pilot Light
Spa Heater -No Pilot Light
Pipe Insulation
WATER2 SIDE SYSTEMS: Chillers, Towers, Boilers, Hydronic Loops
>5 *: "'."- '?.t/^K
.:•*< .- ; -f ;; .'-^fl-
Indicate Page Reference on Plans or Specification2
T-24 Sections
112(a)
123
144(a&b)
144(h)
144(h)
144(j)
144(j)
144(j)
144Q)
144(j)
ch the building plans schedule or specifications. If a requirement is not applicable, put "N/A" in the column
and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification
the required features are documented. If a requirement is not applicable, put "N/A" in the column next to
Service Hot Water, Pool Heating
• '•i."-t??'-;':£*K'r'.4?^WSiS-"S
..•-iRjjxi.'-' •„-•¥• "..:. ,-•*vs:.*g^*
DHW Heater
1
Indicate Page Reference on Plans or Schedule2
T-24 Sections
111,113(3)
113(b)
113(c)
123
Standard Gas 50 gal or Less
0.53 EF
Controls Req.
n/a
114(a)
114(b)
115(c)
115(d)
123
n/a
n/a
n/a
n/a
Required
1 . The Proposed equipment needs to match the building plans schedule or specifications. If a requirement is not applicable, put "N/A" in the column
next to applicable section.
2. For each water heater, pool heater and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or
specification section and paragraph number where the required features are documented. If a requirement is not applicable, put "N/A" in the
column.
EnergyPro 5. 1 by EnergySoft User Number: 1233 RunCode: 2011-04-04712:03:51 ID: Z-306 Page 8 of 12
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
OCO
LU
H
LU
X
LUtr
<
zo1
H
Z
LU
_l
0
7
I MECHAo
Q
O
1Project NameThe Bar Me^^
^-Nw
Jen^••^
0
I
J
1-
LU
UJtr
<N
T-CM
n
VENTILATKHANICALO
UJ
|
izI
CO£m
JUPANCYOO
IEA BASIS<
Z
^
->
-
-»
-
z
o
u.
UJ
o
0
m
to *-
§<
.g> 2 ,_ 'c
Q ii v.
•*- w ^o g ^ £
d •--50% ofDesign ZoneSupplyCFM§,'•§
S|
P .oO3< x 5
w
S •- °
0 0
-0 ^ C
2 £O
!»
jjc
E
1
to
OO10
OO10
10
1
<1>
(0
OO10
•8
fi
I
^
8
^
10
o
OOU501
I
^
8
£(E)HP-D7c
Design Vent(0
£
c
E
O
1
OJ
j)
«H
CO3
c
1
1?co
Minimum ventilatiO
c
V
•o
s without fixerposes for spaceQ.
(f
1
£
T3(C
i
cR
of the CBC ocID
n
SQ3
1
of the expeat or the greaterBased on fixed seUJ
CD
0
BASIS (ColumnOCCUPANCYk BASIS ord on an ARE^3s calculatentilation ratarger of the ve1_w
<on Air (REQ'D VRequired VentilatI difference.ake up theh
S
z
c
8
.2
, or use Tr;-L
O
^is
5
Must be greater t-
i
airflow ratene outdooro
c
I
1in
X
O
LLO
Design fan supplv-
O
!)x0.4CFM/n2Condition area (ft-
ULooP,
0
^—}
I<nc
F
Maximum of Colu-
z'
"3
of Columns Hto the sum15
a0)
0
ro
101
1
Column L <than or equal toThis must be less2
0s
be greater trsfer air mustfe
1
CT<B
jmn M). Where in H minus M.mum Air (Colmn M), ColumDesign Minm Air (Colusater than the)esign MinimuC LJ
O> QJ<n £
c w
F=?>n Air (Colur (Column hjired VentilaticVentilation AP• i
^?ffi
be provided wheence between ttTransfer Air mustequal to the differz
CNJ
O)
Q
T-U)
ojt*e: 2011-04-04RunCoa§i1
1
by EnergySofts
LU
FAN POWER CONSUMPTION MECH-4C
Project Name Date
The Bar Method 4/4/2011
NOTE: Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV)
Fan Systems or Variable Air Volume (VAV) Systems when using the Prescriptive Approach. See Power Consumption of fan §144(c).
A
Fan Description
Supply Fan
B
Design Brake
HP
0.600
C D
Efficiency
Motor
76.0%
Drive
700.0 %
E
Number of
Fans
1.0
F
Peak Watts
B X E X 746 /
(CXD)
589
TOTALS AND ADJUSTMENTS
FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) 1} TQTAL FAN SYSTEM pQWER (WATTS SUM COLUM R
2) SUPPLY DESIGN AIRFLOW (CFM)
A) IHiler pressure drop (SPJ is greater than 1 inch W. C. or 3) TQTAL RAN sysTEM pQWER |NDEX (RQW 1 , RQW 2)
pressure drop across the fan (SP() on Line 5. 4) SPa
5) SP,
B) Calculate Fan Adjustment and enter on line 6. 6) Fan Adjustment = 1 -( SPa - 1 ) / SPf
C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Line 3 x Line 6)1
589
UOO
W/CFM
0.535 W/CFM
1 . TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/CFM for Constant Volume systems or 1 .25
W/CFM for VAV systems.
EnergyPro 5.1 by EnergySoft User Number: 1233 RunCode: 2011-04-04712:03:51 ID: Z-306 Page10of12
FAN POWER CONSUMPTION MECH-4C
Project Name Date
The Bar Method 4/4/201 1
NOTE: Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Ai
Fan Systems or Variable Air Volume (VAV) Systems when using the Prescriptive Approach. See Power Consumption of fan §144(c
A
Fan Description
Supply Fan
B
Design Brake
HP
0.600
C D
Efficiency
Motor
76.0%
Drive
roo.o %
E
Number of
Fans
1.0
r Volume (CAV)
F
Peak Watts
B X E X 746 /
(CXD)
589
TOTALS AND ADJUSTMENTS
FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) 1 , TQTAL pAN sysTEM pQWER (WATTS S(JM CQLUM R
2) SUPPLY DESIGN AIRFLOW (CFM)
A) If filer pressure drop (SPJ is greater thai 1 inch W. C. or 3) TQTAL FAN SYSTEM pQWER |NDEX (Row 1 , RQW 2)
pressure drop across the fan (SPf) on Line 5. 4) SPa
5) SP,
B) Calculate Fan Adjustment and enter on line 6. 6) Fan Adjustment = 1 -( SPa- 1 ) / SPi
C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Line 3 x Line 6)'
589
1,100
W/CFM
0.535 W/CFM
1 . TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 W/CFM for Constant Volume systems or 1 .25
W/CFM for VAV systems.
EnergyPro 5.1 by EnergySoft User Number: 1233 RunCode: 2011-04-04712:03:51 ID: Z-306 Page 11 of 12
Project Name
The Bar Method
Date
4/4/2011
MECHANICAL MANDATORY MEASURES: NONRESIDENTIAL MECH-MM
Equipment and System Efficiencies
§111:Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply
with the applicable standard.
§115(a): Fan type central furnaces shall not have a pilot light.
§123:Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC
equipment, shall be insulated in accordance with Standards Section 123.
§124:Air handling duct systems shall be installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of
the CMC Standards.
Controls
§122(e): Each space conditioning system shall be installed with one of the following:
1A. Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not
explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an
accessible manual override that allows operation of the system during off-hours for up to 4 hours. The time switch
shall be capable of programming different schedules for weekdays and weekends and have program backup
capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or
1B. An occupancy sensor to control the operating period of the system; or
1C. A 4-hour timer that can be manually operated to control the operating period of the system.
2.Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the
system as required to maintain a setback heating and/or a setup cooling thermostat setpoint.
§122(g):
Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000
square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided
with isolation devices, such as valves or dampers that allow the supply of heating or cooling to be setback or shut off
independently of other isolation areas: and shall be controlled by a time control device as described above.
§122(c):Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to
authorized personnel.
§122(b):Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the
heating load can be met by the heat pump alone
Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the
zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the
§122(a&b): control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be
capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or
reduced to a minimum.
Ventilation
§121(e):Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified
on these plans.
§122(f):All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all
openings to the outside, except for combustion air openings.
Ventilation System Acceptance. Before an occupancy permit is granted for a newly constructed building or space, or a
§121 (f): new ventilating system serving a building or space is operated for normal use, all ventilation systems serving the
building or space shall be certified as meeting the Acceptance Requirements for Code Compliance
Service Water Heating Systems
§113(c)Installation
3. Temperature controls for public lavatories. The controls shall limit the outlet Temperature to 110° F.
2 Circulating service water-heating systems shall have a control capable of automatically turning off the circulating pump
' when hot water is not required.
-nergyPro 5.1 by EnergySoft User Number: 1233 RunCode: 2011-04-04712:03:51 ID: Z-306 Page 12 of 12
\ LJ iS1