Loading...
HomeMy WebLinkAbout2660 Madison St; ; CB153668; PermitPrint Date: 11/08/2017 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2660 Madison St BLDG-Residential 2031100101 $262,544.00 1 3.00 BEACHWALK AT MADISON City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit www.carlsbadca.gov Work Class: Lot#: Reference #: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Condo 1 DEV14037 3.00 PC150056 Status: Applied: Issued: Fina led: Inspector: Description: BEACHWALK: UNIT 1/PLAN A/ 1,607 SF LIVING/488 SF GARAGE/75 SF 2ND FLOOR DECK/117 SF 3RD FLOOR DECK Owner: Co-Applicant: Permit No: CB153668 Closed -Finaled 10/28/2015 12/19/2016 M R CARLSBAD 11 LLC VESTA PACIFIC DEVELOPMENT INC BUILDING PERMIT FEE $2000+ BUILDING PLAN CHECK FEE (BLDG) 1818 1St Ave, 100 SAN DIEGO, CA 92101 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -outside CFD SB1473 BUILDING STANDARDS FEE SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement SEWER CONNECTION FEE (General Capacity all areas) STRONG MOTION-RESIDENTIAL TRAFFIC IMPACT Residential Condo Outisde CFD WATER METER FEE 5/8" Displacement WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P) WATER TREATMENT CAPACITY CHARGE 5/8" Displacement Total Fees: $24,357.42 Total Payments To Date: $24,357.42 1818 1St Ave, Suite 100 San Diego, CA 92101-2662 619-481-3830 Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. $0.00 $1,204.65 $676.60 $66.00 $166.00 $92.00 $182.00 $9,189.04 $11.00 $4,840.00 $899.00 $34.13 $2,584.00 $277.00 $4,013.00 $123.00 . , PERMIT INSPECTION ~ISTORY REPORT (CB153668) Permit Type: BLOG-Residential Application Date: 10/28/2015 Owner: Work Class: Condo Issue Date: 12/19/2016 Subdivision: Status: Closed -Finaled Expiration Date. 12/11/2017 Address: IVR Number: 710146 Actual Scheduled Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 11/08/2017 11/08/2017 BLDG-Final Inspection Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electncal Final 039961-2017 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final COMMENTS COMMENTS Passed Michael Collins COMMENTS See back of card for corrections AFCI, GFCI, Smoke & Co detectors ok. T-24 ok COMMENTS See back of card for corrections AFCI, GFCI, Smoke & Co detectors ck. T-24 ok M R CARLSBAD 11 LLC 2660 Madison St Carlsbad, CA 92008 Reinspection Passed No No No No No Passed No No No No No Passed Yes Yes Yes Yes Yes Passed Yes Yes Yes Yes Yes Complete Complete ~~ ~~-----------------------------------------------------------------------------------------------------November 08, 2017 Page 4 of 4 PERMIT INSPECTION HISTORY REPORT (CB153668) Permit Type: BLDG-Residential Application Dato: 10/28/2015 Owner: Work Class: Condo Issue Date: 12/19/2016 Subdivision: Status: Closed -Finaled Expiration Date: 12/11/2017 Address: IVR Numbor: 710146 Actual Scheduled Date Start Date Inspection Type Inspection No. 08/03/2017 08/03/2017 08/14/2017 08/14/2017 09/25/2017 09/25/2017 11/07/2017 11/07/2017 November 08, 2017 Checklist Item BLDG-Building Deficiency BLDG-17 Interior Lath-Drywall BLDG-18 Exterior Lath and Drywall BLDG-23 Gas-Test-Repairs BLOG-Electric Meter 030540-2017 Release Checklist Item BLDG-Building Deficiency Checklist Item BLDG-Building Deficiency BLOG-Electric Meter 031544-2017 Release Checklist Item BLDG-Building Deficiency Checklist Item BLDG-Building Deficiency BLOG-Gas Meter Release 035683-2017 BLOG-Final Inspection Checklist Item BLDG-Building Deficiency Checklist Item BLDG-Building Deficiency 039778-2017 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Inspection Status Primary Inspector COMMENTS Except shower/tub areas. Falled Paul Burnette COMMENTS COMMENTS Passed Michael Collins COMMENTS EMR emailed to SDGE, includes 2558 HM COMMENTS EMR emailed to SDGE, includes 2558 HM Passed Michael Collins COMMENTS GMR emailed to SDGE COMMENTS GMR emailed to SDGE Falled Michael Collins COMMENTS See back of card for corrections COMMENTS See back of card for corrections M R CARLSBAD 11 LLC 2660 Madison St Carlsbad, CA 92008 Reinspection Passed Yes Yes Yes Yes Reinspectlon Passed No Passed No Passed Yes Passed Yes Passed Yes Passed Yes Reinspection Passed No No No No No Passed No No No No No Complete Complete Complete Complete Complete Page 3 of 4 . ,, . /' PERMIT INSPECTION HISTORY. REPORT (CB153668) Permit Type: BLDG-Residential Application Date: 10/28/2015 Owner: M R CARLSBAD 11 LLC Work Class. Condo Issue Date: 12/19/2016 Subdivision: Status: Closed -Finaled Expiration Date: 12/11/2017 Address: 2660 Madison St Carlsbad, CA 92008 IVR Number: 710146 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 05/30/2017 05/30/2017 BLDG-84 Rough 024669-2017 Passed Paul York Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers 06/08/2017 06/08/2017 BLDG-18 Exterior 025641-2017 Passed Paul York Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No Checklist Item COMMENTS Passed BLDG-Building Deficiency No 06/12/2017 06/12/2017 BLDG-82 Drywall, 025929-2017 Passed Michael Collins Complete Exterior Lath, Gas Test, Hot Mop Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-17 Interior Lath-Drywall Except shower/tub areas. Yes BLDG-16 Exterior Lath and Yes Drywall BLDG-23 Gas-Test-Repairs Yes November 08, 2017 Page 2 of 4 PERMIT INSPECTION HISTORY REPORT (CB153668) Permit Type: BLDG-Residential Application Dato: 10/28/2015 Owner: M R CARLSBAD 11 LLC Work Class: Condo Issue Date: 12/19/2016 Subdivision: Status Closed -Finaled Expiration Date: 12/11 /2017 Address: 2660 Madison St Carlsbad, CA 92008 IVR Number· 710146 Scheduled Actual Primary Inspector Reinspection Complete Date Start Date Inspection Ty pe Inspection No. Inspection Status 12/20/2016 12/20/2016 BLDG-21 006288-2016 Passed Paul York Complete Underground/Underf loor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency No Checklist tern COMMENTS Passed BLDG-Building Deficiency No 01/18/2017 01/18/2017 BLDG-1 1 009925-2017 Passed Paul York Complete Foundation/Ftg/Pier s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency No Checklist ltom COMMENTS Passed BLDG-Building Deficiency No 01/26/2017 01/26/2017 BLDG-11 011278-2017 Passed Paul York Complete Foundation/Ftg/Pier s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency No Checklist Item COMMENTS Passed BLDG-Building Deficiency No 03/30/2017 03/30/2017 BLDG-15 018249-2017 Partial Pass Paul York Reinspection Incomplete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency No Checklist Item COMMENTS Passed BLDG-Building Deficiency No 05/26/2017 05/26/2017 BLDG-84 Rough 024576-2017 Cancelled Paul Burnette Relnspection Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 No Frame-Sleel-Bolt1ng-Welding (Decks) BLDG-24 Rough-Topout No BLDG-34 Rough Electrical No BLDG-44 No Rough-Ducts-Dampers November 08, 2017 Page 1 of 4 f<t:L,uRD COPY ~ INSPECTION RECORD Iii WWW:IAM WOiiO CAIID WITH APPROVED i11Am mun• KEPT' ON 1HE .JOII C8153888 ,, 2880 MADISON ST BEACHWALK UNIT 11A.AN Al 1 007 SF UVING/488 SF GARAGEll5 SF 2ND FLOOP DE0</117 SF 3RD FLOOR DECK RESONTL CONDO la# VESTA PACIFIC DEVELOPMErrr fr«; ..._,l'lewwwaluaa 760-602 4'60 _ .. _ .,... .. fJldW heUon N11, HNHh Md._,.. Code,--. of c•ow• 00 T11e,e .,_ ti. r101 r.te ,.-, a,,.,--. do:A« fof ~ '1J ~ "~,:11 ~ 1'~.f _..,...,.~ 41'. • ciotlW~..... fr......., Cl(,Mf 1f.111J (/"'1Mt flt.,...,...~ t,,$4: ..... (b1 Fot ti,, IIU'pQM d ,_ ~fie-~ ,.,..,.._.~ ._ v~ ~ ,.,_ .-.,....-o,: ?: i,r;q: ;;,,::1.;.:a ~·.r.111'~'-.-/ ~ ~-inprog,fM (c) A~dNt~Allflall~a ~ Aj contfrUCliotl (J( l#Otlr fof ~ a fAl(trJf • t~Mt(I tl'.ialf t.. ~...t I<, l'~JV., ¥1! ~I 1;;n '//llllt~,1< ,., ,.,.,.._~ .,.,. ,..,_, ac:c"MN and~ t(,;r ill'~ ~,VA<N rrM ~~*' D/t!ft ~.:U fk.ll V:al ~~'l'"-' ~..-~ ~,,. poirlC tll'ldlr..-ed ,r. '*"' IUO'AtV ... Ir'~ ..,..,,.c .... ~ .... ~.?4'1(./.~~ 't!'ltl'~.r INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope -Insulation; Roofing; Fenestration (Page 1 of 3) . Site Address: I Enforcement Agency: 2660 MADISON STREET BLDG 2.. CARLSBAD CA, 92008 I Permit Number: If more than one person has responsibility for installation of the items on this certificate, each person shall prepare and sign a certificate applicable to the portion of construction for which they are responsible; alternatively, the person with chief responsibility for construction shall prepare and sign this certificate for the entire construction. All applicable Mandatory Measures with check boxes require to be checked to ensure the mandatory measures have been met. Description of Insulation 1. RAISED FLOOR Material: Brand Name: ------------~ Thickness (inches): Thermal Resistance (R-Value): ______ _ D § lSO(d): Minimum R-13 insulation in raised wood-frame floor or equivalent U-factor. 2. SLAB FLOOR/PERIMETER Material: ______________ _ Brand Name: ____________ _ Thickness (inches): __________ _ Thermal Resistance (R-Value): ______ _ Perimeter Insulation Depth (inches): ____ _ 0 §150(1): Water absorption rate for the insulation material alone without facings is no greater than 0.3%; water vapor perrneance rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration. 3. EXTERIOR WALL a. Insulation Type (e.x. Batt, Loose Fill, Spray Foam) Batt b .. Insulation Type (e.x. Batt, Loose Fill, Spray Foam) Brand: CertainTeed Spray/Loose fill) Installed Actual Thickness (inches): ____ _ a. Thermal Resistance (R-Value): _R_-1_5 ____ _ b. Thermal Resistance (R-Value): ______ _ Spray/Loose fill) Contractor's min installed weight/ft2 __ lb Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value) D §150(c): Minimum R-13 insulation in wood-frame wall or equivalentU-factor. Exterior Foam Sheathing (rigid Insulation) Material: ______________ _ Brand Name: ------------~ Thickness (inches) : __________ _ Thermal Resistance (R-Value) : ______ _ 4. FOUNDATION WALL Material: ______________ _ Brand Name: __ ·~--~--------- Thickness (inches): __________ _ Thermal Resistance (R-Value): ____ _ 5. CEILING Batt or Blanket Type: Batt Brand Name: _C_e_rt_a_in_T_ee_d _______ _ Loose Fill Type: Thermal Resistance (R-Value): _R_-3_0 ____ _ Spray Foam Type: Brand Name:------------- Installed Actual Thickness (inches): Contractor's min installed weight/ft2 lb Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Value): D §lSO(a): Minimum R-19 insulation in wood-frame ceiling or equivalent U-factor. 6. ATTIC ROOF INSULATION AND/OR ATTIC RADIANT BARRIER Material: Brand Name: -------------Material: Brand Name: -------------Thickness (inches): Thermal Resistance (R-Value): ______ _ D § 118 (a): Insulation installed meets Standards for Insulating Material. D § l SO(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. 2008 Residential Compliance Forms August 2009 INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope -Insulation; Roofin~; Fenestration (Pagel of3) Site Address: I Enforcement Agency: 2660 MADISON STREET BLDG 2. CARLSBAD CA, 92008 I Permit Number: Description of Roofing Products CRRC Product ID Manufacturer Product Roof Roof Product Initial Solar Aged Solar Thermal Number' Information Brand/Model Type Area Slope Weiruit 2 Reflectance Reflectance4 Emittance N/A 03 03 03 1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at ww. coo/roofs. orglproductslsearch.php 2. The weight in lbs per square feet of the roofing product being installed. 3. Check box if the Aged Reflectance is a calculated value using the equation below, footnote 4. 4. If the aged reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the initial reflectance value from the directo,y and use the equation (0.2+0. 7(/Ji•ifial-0.2) to obtain a calculated a!,!ed value . ./ ti CHECK APPUCABLE BOX BELOW IF EXEMPT FROM THE ROOFING PRODUCT "COOL ROOF" REQUIREMENT: a The roof area covered by building integrated photovoltaic panels and building integrated solar thermal panels are exempt from the above Cool Roof criteria. CJ Roof constructions that have thermal mass over the roof membrane with a weight of at least 25 lb/ft' is exempted from the above Cool Roof criteria. To apply Liquid Field Applied Coatings, the coating must be applied with a minimum dry mil thickness of 20 mils across the entire roof surface and meet minimum l)erformance requirements listed in § J J 8(i)3 and Table 118-C. Select the avTJlicable coatinJ;? C Aluminum-Pigmented Asphalt Roof Coating I D Cement-Based Roof Coating I lJ Other ./ CJ CRRC-1 Label Attached to CF-6R (Note if no CRRC-1 label is available, this compliance method cannot be used and another method is required to meet compliance). FENESTRATION/GLAZING Product # Total Quantity Add. Exterior Comments/ Manufacturer/Brand Name U-Product of NFRC of Like Product Area Shading Dev. Location/ Special Item (GROUP LIKE RODUCTS) factor1 SHGC 1 Panes Certified 1• 2 (Optional) r ft' or Overhang Features I NIA 2 3 4 5 6 7. 8. ] . Use values from a fenestration product's NFRC Certified Label. For fenestration products without an NFRC label, use the default values.from Section 1 i 6, Table 116-A and 116-B of the 2008 Energy Efficiency Standards, 2. NFRC Label Certificates shall not be removed until the buildinJ! inspector has verified the efficiency. Enter Yes or No. D § 1 l 6(a)l: Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. D § 116(a)2 and 3: Actual fenestration products installed are equivalent to or have a lower U-factor and/or a lower SHGC than that specified on the Certificate of Compliance (Fann CF-IR). D § l 16(a)4: Fenestration products (except field-fabricated windows) have a label listing the certified U-Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration that meets the requirements of§ 10-111 (a) C § 117: Exterior doors and windows weather-stripped; all joints and penetrations caulked and sealed. 2008 Residential Compliance Fomis August 2009 INSTALLATION CERTIFICATE CF-6R-ENV-01 Envelope -Insulation; Roofine:; Fenestration (Page 3 of3) Site Address: I Enforcement Agency: 2678 MADISON STREET BLDG 1. CARLSBAD CA, 92008 I Permit Number: DECLARATION STATEMENT • I certify under penalty of perjury, under the laws of the State of California, the information provided on this fonn is true and correct. • I am eligible under Division 3 of the Business and Professions Code to accept responsibility for construction, or an authorized representative of the person responsible for construction (responsible person). • I certify that the installed features, materials, components, or manufactured devices identified on this certificate (the installation) conforms to all applicable codes and regulations, and the installation is consistent with the plans and specifications approved by the enforcement agency. • 1 reviewed a copy of the Certificate of Compliance (CF-lR) form approved by the enforcement agency that identifies the specific requirements for the installation. I certify that the requirements detailed on the CF-lR that apply to the installation have been met. • I will ensure that a completed, signed copy of this Installation Certificate shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a signed copy of this Installation Certificate is required to be included with the documentation the builder provides to the building owner at occupancy. Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Truteam of California Responsible Person's Name: Nicole Flores CSLB License: 221517 2008 Residential Compliance Forms Date Signed: 05/31/2017 Responsible 1JC;ts Position With Company (Title): Operation Support Specialist August 2009