Loading...
HomeMy WebLinkAbout2661 DAVIS AVE; ; CB061249; Permit05-07-2007 Job Address Permit Type Parcel No Valuation Occupancy Group # Dwelling Units Bedrooms Project Title City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No CB061249 Building Inspection Request Line (760) 602-2725 2661 DAVIS AV CBAD RESDNTL 1552720800 $1,75600 0 0 WALSH RES 66 SF GARAGE ADDITION Sub Type Lot# Construction Type Reference # Structure Type Bathrooms RAD 0 NEW Applicant WALSH FAMILY TRUST 12-14-01 2661 DAVIS AVE CARLSBAD CA 92008 Status Applied Entered By Plan Approved Issued Inspect Area Ong PC# Plan Check# EXPIRED 05/05/2006 MP Owner WALSH FAMILY TRUST 12-14-01 2661 DAVIS AVE CARLSBAD CA 92008 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee HMP Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $34 77 Meter Size $0 00 Add'l Reel Water Con Fee $22 60 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $1 00 PFF (3105540) $0 00 PFF (4305540) $0 00 License Tax (3104193) $0 00 License Tax (4304193) $000 Traffic Impact Fee (3105541) $0 00 Traffic Impact Fee (4305541) $0 00 Sidewalk Fee $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $000 MECHANICAL TOTAL $0 00 Housing Impact Fee $0 00 Housing InLieu Fee $0 00 Housing Credit Fee Master Drainage Fee $0 00 Sewer Fee $0 00 Additional Fees TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $5837 Total Fees $58 37 Total Payments To Date $0 00 Balance Due $5837 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations, or other exactions hereafter collectively referred to as "fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes nor planning zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. City of Carlsbad Building Department MARCH 6, 2007 WILLIAM WALSH JR 2661 DAVIS AV CARLSBAD CA 92008 RE APPLICATION DATE 05/05/2006 PLAN CHECK # CB061249 ADDRESS 2661 DA VIS AV EXPIRATION DATE 05/05/2007 PERMIT TYPE RES DESCRIPTION 66 SF GARAGE ADDITION You applied to have your plans checked on the date noted above To date, the related building permit has not been obtained The original plan review application will expire as no building permit has been issued Plans submitted and not retrieved from the building department prior to the plan check expiration date noted above will be destroyed The provisions of sections 304 (d) of the Uniform Building Code state "Section 304 9d) Expiration of Plan Review Applications for which no permit is issued within one year following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee " In order to provide better service, please indicate your handling choice for the plans originally submitted and return this letter to the Building Department Project Abandoned -1 will pick up the plans within 10 days Project Abandoned - Plans may be destroyed If you have any questions, please contact the Building Department at (760) 602-2719 Building Department 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-270O Building Counter • (760) 602-2719 • FAX (760) 602-8558 PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO _££cd——- f EST VAL Plan Ck Deposit Validated By ^_ Date fs_ Address (include Bldg/Suite #) Legal Description Assessor s Parcel # Description of Work ^ ^~ Business Name (at this address) Lot No Subdivision Name/Number Unit No Phase No Existing Use Proposed Use . SQ FT / #of Stories # of Bedrooms Total ft of units # of Bathrooms i (if iifferant from applicant] Name 3. Address PCoBiftBtor. ..QAgent for Contractor, Sffewner D Agent ft itx:k, *2.6>u bfrifo AV^ City otCXvper State/Zip Telephone # Fax # Address City State/Zip Telephone # Address City State/Zip Telephone # -COMPANY NAME Name &i (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law [Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) Name State License # Address License Class City State/Zip City Business License tt Telephone # Designer Name State License # 6; WORKERS' COMfi Address N^WWte:^"" ' i6"i : City State/Zip Telephone •' '• :H-'jS'.X-'iki' ••"„.•.„:. ..' ••••• •.-.^••^"* * •-•• •••••••^•- 3- Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations l~l I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued n I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My worker s compensation insurance carrier and policy number are Insurance Company _ Policy No _ Expiration Date _ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) l~l CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage a unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100 000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees SIGNATURE _ DATE _ I hereby affirm that I am exempt from the Contractor s License Law for the following reason Q I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) n I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) C] I am exempt under Section _ Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement D YES QNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone number / contractors license number) __ __ _ 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) _ __ __ PROPERTY OWNER SIGNATURE DATE coMpijTCms sRltiC^ ;;••; .:.:::::::::::::i..:;f;\:...-.: .u ::"?is:s2A :: ^SRA-' Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? Q YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? O YES Q NO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site? D YES Q NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT «, CONSTRUCTION LENDING AGENCY ,. 1 . <->>•*::•••••• '.: ;. •:" " ' I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER S NAME LENDER S ADDRESS 9, APMJCAJIO-CERTIFICATION ,. :' : mm.f I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the iMMjpinuaof this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not comfTJeruted within 180 days fr«(n\tha^atefof sucftpermit or if the building or work authorized by such pffriit is susjfended or abandoned at any time after the work is corn/Mpdeanr a periodaMao a^ysA9fec*>j/V)6 yf Uniform Building Code) APPLICANT S SIGNATURE C^AJWlZ^^ frf fe^ffAlij ?C[ ^/ DATE WHITE File Applicant PINK Finance EsGil Corporation In (Partnersnip with government for (Buififtng Safety DATE May 15, 2006 ^iL^EPUCANJ JURISDICTION Carlsbad a FILE PLAN CHECK NO CB061249 SET I PROJECT ADDRESS 2661 Davis Ave. PROJECT NAME Addition for the Walsh Residence I | The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes I | The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff I | The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck IXI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I | The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person IXI The applicant's copy of the check list has been sent to William Walsh Jr 2661 Davis Ave Carlsbad, CA 92008 I | Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted William Walsh £/**\ Telephone # (760) 720-4272 Date odm^l^^lW (by ^} Fax # None Provided Mail ^-^felephone w/rax In Person REMARKS By Steve Sanders Enclosures Esgil Corporation D GA D MB D EJ D PC 5/5/06 trnsmtldot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576 Carlsbad CB061249 May 15, 2006 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO CBO61249 PROJECT ADDRESS 2661 Davis Ave. FLOOR AREA Addition 66 sq ft REMARKS DATE PLANS RECEIVED BY JURISDICTION 5/5/06 DATE INITIAL PLAN REVIEW COMPLETED May 15, 2006 JURISDICTION Carlsbad STORIES 1 HEIGHT 15'-6" Approx DATE PLANS RECEIVED BY ESGIL CORPORATION 5/5/06 PLAN REVIEWER Steve Sanders FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24), which adopts the following model codes 1997 UBC, 2000 UPC, 2000 UMC and 2002 NEC The above regulations apply to residential construction, regardless of the code editions adopted by ordinance The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i e . plan sheet number, specification section, etc Be sure to enclose the marked up list when you submit the revised plans Carlsbad CB061249 May 15, 2006 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1 All sheets of plans must be signed by the person responsible for their preparation (California Business and Professions Code) 2 Specify on the Title Sheet of the plans the gross floor area of each element of this project, including the garage Section 106 3 3 Garage floor area shown on the plans differs from the floor area on the Permit application Please clarify 3 Please remove all information from the plans referencing construction not under this building permit including notes, architectural and structural details 4 Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 editions of the California Building/Plumbmg/Mechanical Codes and the 2004 edition of the California Electrical Code, which adopt the 1997 UBC, 2000 UMC, 2000 UPC and the 2002 NEC 5 Provide a fully dimensioned site plan drawn to scale Section 106 3 3 Include the following a) North arrow b) Property lines/easements c) Streets/alleys d) Existing and proposed buildings and structures 6 Clearly dimension building setbacks from property lines, street centerlmes, and from all adjacent buildings and structures on the site plan Section 106 3 3 Carlsbad CBO61249 May 15, 2006 7 On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below Section 106 3 2 • REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec 1701 of the Uniform Building Code ITEM REQUIRED? REMARKS EXPANSION/EPOXY ANCHORS YES HD22SG16 8 When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit Please review Section 106 3 5 Please complete the attached form 9 Show at the garage the method of bracing garage front at the proposed addition and holddowns if required Chapter 16 NOTE Maximum shear panel height-to-width ratio is 31/2 -to-1 for plywood Table 23-ll-G In Seismic Zone 4, this 31/2-to-1 ratio is only permitted in one-story garages with a wall height not exceeding 10 feet 10 Note the proposed "Rannai" tankless water heater in the garage will be located a minimum of 18 inch above the floor UMC Section 303 1 3, UPC Section 510 1 11 Ridges shall be at least one size larger than supported rafters Section 2320 123 Please show the size of the ridge serving the proposed garage addition and how it will interface with the existing ridge 12 Please show or note how the proposed tankless water heater will be vented 13 Show on the plans compliance with the residential energy lighting requirements (Mandatory requirement) a) Outdoor lighting fixtures are required to be high efficacy or controlled by a combination photocontrol/motion sensor Note Generally a high efficacy style of fixture is fluorescent complete with electronic ballasts Regular incandescent, quartz halogen and halogen MR lamps do not comply Carlsbad CB061249 May 15, 2OO6 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans • Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Steve Sanders at Esgil Corporation Thank you Carlsbad CB061249 May 15, 2006 City of Carlsbad Building Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No CB061249 Job Address or Legal Description 2661 Davis Ave. Owner Address You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection dunng the performance of the phases of construction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet Carlsbad CB061249 May 15, 2006 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION PLAN CHECK NUMBER OWNER'S NAME I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special mspector(s) as required by Uniform Building Code (UBC) Section 1701 1 for the construction project located at the site listed above UBC Section 106 3 5 Signed I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106 3 5 for the construction project located at the site listed above Engineer's/Architect s Seal & Signature Here Signed 1 List of work requiring special inspection Q Soils Compliance Prior to Foundation Inspection Q Field Welding G Structural Concrete Over 2500 PSI D High Strength Bolting Q Prestressed Concrete Q Expansion/Epoxy Anchors Q Structural Masonry Q Sprayed-On Fireproofmg n Designer Specified d Other 2 Name(s) of mdividual(s) or firm(s) responsible for the special inspections listed above A B C 3 Duties of the special inspectors for the work listed above A B Special inspectors shall check in with the City and present their credentials for approval prior to beginning work on the job site Carlsbad CB061249 May 15, 2006 JURISDICTION Carlsbad VALUATION AND PLAN CHECK FEE PREPARED BY Steve Sanders BUILDING ADDRESS 2661 Davis Ave PLAN CHECK NO CB061249 DATE May 15, 2006 BUILDING OCCUPANCY U-l TYPE OF CONSTRUCTION VN BUILDING PORTION Garage Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 66 cb Valuation Multiplier 2661 By Ordinance Reg Mod VALUE ($) 1,756 1,756 Bldg Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review 0 I I Repetitive FeeRepeats Complete Review D Other I-, Hourly Structural Only Hour Esgil Plan Review Fee $34 77 $2260 $1947 Comments Sheet 1 of 1 macvalue doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER ADDRESS RESIDENTIAL RESIDENTIAL ADDITION MINOR (<$10,000.00) DATE TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER ENGINEER DATE DATE DocVMijfomwPlBnrana Engmacring Approvals PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No CBQ(p* / Planner Chris Sexton APN Address Phone (760) 602-4624 Type of Project & Use; Zoning ft»X General Plan. CFD (in/out) #_Date of participation Net Project Density . 31 DU/AC Facilities Management Zone _l_ Remaining net dev acres Circle One (For non-residential development Type of land used created by this permit ) Legend ^ Item Complete G Item Incomplete - Needs your action Environmental Review Required YES NO j^TTYPE DATE OF COMPLETION Compliance with conditions of approval' If not, state conditions which require action Conditions of Approval Discretionary Action Required APPROVAL/RESO NO PROJECT NO YES NO iX TYPE. DATE OTHER RELATED CASES Compliance with conditions or approval? If not, state conditions which require action Conditions of Approval n Mri n Coastal Zone Assessment/Compliance Project site located in Coastal Zone' YES_ CA Coastal Commission Authority' YES_NO If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402, (619) 767-2370 Determine status (Coastal Permit Required or Exempt) Habitat Management Plan Data Entry Completed' YES.NO If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE') Inclusionary Housing Fee required YES _ NO (Effective date of Inclusionary Housing Ordinance - May 21 , 1993 ) Data Entry Completed' YES.NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE") H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 Site Plan D Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes) Provide legal description of property and assessor's parcel number D D an ana nan a Policy 44 - Neighborhood Architectural Design Guidelines 1 Applicability YES. NO_ 2 Project complies YES NO Zoning 1 Setbacks Front Required Interior Side Required Street Side Required Rear Required TOD of slope Required 2 Accessory structure setbacks Front Required Interior Side Required Street Side Required Rear Required Structure separation Required 3 Lot Coveraae Required 4 Heiaht Required O5 Parking Spaces Required O\^ (breakdown by uses for commercial and Residential Guest Spaces Required Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown njudL 30* 30Q6J\eL&^ ShowrV/ 0 industrial projects required) Shown Additional Commen OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 CBOS1249 2661 DAVIS AV CBAD 66 SF GARAGE ADDITION RESDNTL RAD LoW WALSH FAMILY TRUST 12 1401 -V g/nfov lOCMPUTE fid! CO*