Loading...
HomeMy WebLinkAbout2662 Gateway Rd; 155; CBC2018-0150; PermitCcityof Carlsbad Commercial Permit Print Date: 02/28/2019 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: Description: Applicant: 2662 Gateway Rd, 155 BLDG-Commercial 2132622100 $365,382.56 BEVMO: 7,856 SF Tl SHELL TO RETAIL Owner: Work Class: lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Tenant Improvement ROB BOUCKE 8008 E Arapahoe Ct Centennial, CO 80112-6839 720-529-8768 SHEA PROPERTIES MANAGEMENT CO INC MICHAEL LAWSON BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) 130 Vantis Or Aliso Viejo, CA 92656-2691 858-562-6500 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL PLUMBING BLDG COMMERCIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -inside CFO SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-COMMERCIAL Total Fees: $9,836.78 Total Payments To Date: $9,836.78 Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Permit No: CBC2018-0150 Closed -Finaled 03/19/2018 08/30/2018 AKrog 2/28/2019 9:47:18AM $0.00 $1,570.30 $1,099.21 $89.00 $170.00 $55.00 $86.00 $6,649.96 $15.00 $102.31 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov l'HE FOLL,"IING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: □PLANNING □ENGINEERING □BUILDING □FIRE □HEALTH □HAZMATIAPCD I (city of Building Permit Application Plan Check NoQ3::_~ ti?-ntSD 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value t/:J 5{,,y, 2-'K::J. G ~ Carlsbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit email: building@carlsbadca.gov www.carlsbadca.gov Date · 7J/ / q / f'){ jSWPPP JOB ADDRESS SUITl!I/SPACEf/UNrT# rPN 2662 Gateway Road Suite #155 213 -262 -09 -00 1..,,,c,,OJE..,,,.. I LOT# I PnASE,, I l'''\i1A-ff DATHROOr,,S I TENANT au .. ,NESS NAME r"O;B E I -~ Mou, N/A 1 Beverages & Morel DESCRIPTION OF WORK: Include Squaf9 Feet of Affecuov Area(s) TENANT IMPROVEMENT OF (E) VACANT 7,856 S.F. BUILDING SPACE FOR RETAIL FOOD MARKET. NEW INTERIOR PARTITIONS, DOORS, CEILINGS, FINISHES, AND FIXTURES. NEW PLUMBING, NEW LIGHTING/ELEC, NEW HVAC DUCTWORK TO TIE INTO EXISTING ROOFTOP HVAC UNITS. NO SITE WORK PROPOSED. FIREPLACE EXISTING USE I PROPGSED USE VACANT· MERCANTILE MERCANTILE I GARAG; (SF) PATIOS (SF) I DECKS (SF) 0 0 YESO I AIR CONDITIONING I FIRE SPRINKLERS N0 YESIZ)No □ YESIZ)No□ APPLICANT NAME Rob Boucke c/o MCG Architecture PROPERTY OWNER NAME Amber Wesley c/o Shea Properties Primary Contact ADDRESS ADDRESS 8008 E. Arapahoe Court, Suite 100 130 Vantis Dr., Suite 200 CITY STATE ZIP CITY STATE ZIP Centennial co 80112 Aliso Viejo CA 92656 PHONE PHONE 720-529-8768 I FAX 949-389-7236 I FAX 949-389-7434 EMAIL EMAIL rboucke@mcgarchitecture.com Amber.Wesley@sheaproperties.com DESIGN PROFESSIONAL Same as applicant CONTRACTOR BUS, NAME TBD ADDRESS ADDRESS CITY STATE ZIP CITY STATE ZIP PHONE IFAX PHONE rAX EMAIL EMAIL ]STATE UC.# STATE LIC.# 'CLASS I CITY BUS. L\C.# (Sec. 7031.5 Business and Professions Code: Any City or Cou,:ify which requires a permit to construct, alter, Improve, demolish or rel)a.lr any structure, prior to Its Issuance, also requires the applfcant for such permit to file a signed statement tflat he ts licensed pursuant to the provisions of the Contractor's License Law {ChaD'terB, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he Is exemDt therefrom, and the basis for the alleged exemption. Any vlolatlon of Section 7031.5 by any appllcan'ffor a permit subjects the appllcant to a clvll penalty of not more than five hundred dollars {$500)). . WORKERS' COMPENSATION Workers' Comp1111atlon Declaration:/ haret,y affl,m under penalty of perjury one of the following dec/aratlons: B I have and will maintain a certfflcatt of conaent to nlf-ln1ure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit \a Issued. I have 1nd°'w1u maintain workers' compensation, as reQulred by Section 3700 of the Labor Code, forth& performance of the work for which this permit Is Issued. My workers' compensatkln Insurance carrier and policy number are: Insurance Co. __________________ Polley No. ____________ ExplratlonDate _______ _ T,bl§, section need not be completed If the permit Is for one hundred dollars ($1 00) or less. LJ Certificate of Exemption: I certify that In the performance of the work for which this pem,lt Is lssued, I shaU not employ any person In any manner so as to become subject to the Workers' Compensation Laws of Callfomla. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and clvll fines up to one hundred thousand dollars (&100,000), In addition to the cost of compensation, damages II provided for In Section 3706 of the Labor code, lntarut and attorney's fffl. 2S C0NTRACTORSIGNATURE □AGENT DATE OWNER-BUILDER DECLARATION I hereby afflrm that I am exempt from Contractor's Ucanse Law for the fol/owing reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work end the structure Is not Intended or offered for sale {Sec. 7044, Business and Professions Code: The Contractofs License Law does not apply to an owner of property who builds or Improves thereon, and who does such work himself or through his own employees, provided that S\Jch Improvements are not Intended or offered for sale. If, however, the 'oulldlng or Improvement Is sold within one year of completion, the owner-bulkier wlti have the burden of proving that he did not bu Md or Improve for the purpose of sale). □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors License Law does not apply to an owner of property woo buOds or Improves thereor1i and contracts for Sl!Ch projects with contracto~s) lk:ensed purauant to the Contractors License Law). I am exempt under Sectlon ___ ~•USlness and Professions Code for this reason: 1. 1 personaUy plan to provide the major labor and materials for construction of the proposed property Improvement 0Yes Do 2. I (have I have not) signed an appllcatlon for a buRding permit forth& proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (Include name address/ phone/ contractors' license number~ 4. 1 plan to provide portions of the work, but I have hired the fellowing person to coordinate, supeNlse and provide the major work (Include name/ address/ phone I contractors' Rcense number): 5. I wll.l provide some of the work, but I have contracted (hired) the following persons to provide the work Indicated (Include name I address/ phone /type of work}: 2S PROPERTY OWNER SIGNATU □AGENT DATE --~ -~ ---~--~ - COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY --~ -~ ~ • ---J - Is the appllcant or future bulldlng occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under SecOons 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes v No ls the applicant or future building occupant required to obtain a permit from the air pollution control district or air Qualily management district? Yes Y No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes v No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND lllE AIR POLLUTION CONTROL DISTRICT. I hereby affinn that there is a C011struclion lending agency for the perfonnance of the work this permit is Issued (Sec. 3097 (i) CMI Code). I C8flffythat I have read the applk:atlon and state that the above Information Is conffl and that the Information on the plans Is accuratB. I agree to complyv.tth all City ordinances and State laws relating to bulldlng consbuctlon. I hereby aulholize _,,1at1ve of ~e Cfy of Carlsbad ID enter upon ~e above mentioned property for Inspection purpoees. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY Of CARLSBAD AGAINST ALL LIABILmES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OFTHIS PERMIT. OSHA: An OSHA pennl Is requn!d for exa,V8Uor1S over s•~ deep end demolWon or c:onslructlon of mJchlles aver 3 siDlles In ~l EXPIRATION: Every pennl Issued by the Bul~lng Offldal under ~e provlsklns of ~Is Code shall expire by nmllatlon end become nuH and vo~ ! the bul~"ll or work a~orlzed by such pem,t Is not comrr,nced ll'lm 180 days from the dale of such pennl or ! the b Ing or rk aulhorized by such pennlt Is suspended or abandoned at any tirre alter ~• work Is commenced ror a period of 180 days (Sedion 106.4.4 Uniform Bul~lng Code), -@S' APPLICANT'S SIGNATURE DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CERTilFICATE OF OCCUPANCY (Commercial Pro1ccts 0 n I _v) Fax (760) 602-8580, Email bullding@carlsbadca.gov or Mall the completed fonn to City of Carlsbad, Building DMslon 1635 Faraday Avenue, Carlsbad, Callfomla 92008. CO#: (Office Uae Only} CONTACT NAME Rocio Clough c/o BevMo! OCCUPANT l'IAME Beverages & Morel (dba BevMo!) ADDRESS 1401 Willow Pass Road, Suite 900 BUILDING ADDRt.:J:a 2662 Gateway Road -Suite #155 Cl1Y STATE ZIP Cl1Y STATE ZIP Concord CA 94520 Carlsbad CA 92009 PHONE I FAX 925-609-607 4 EMAIL OCCUPANT'S BUS. LIC. No. cloughr@bevmo.com Pending DELIVERY OPTIONS PICKUP: CONTACT (Usted above) OCCUPANT (Usted above) CONTRACTOR (On Pg. 1) ~ MAIL TO: CONTACT (Listed above) "' OCCUPANT (Usted above) ASSOCIATED CH CONTRACTOR (On Pg. 1) NO CHANGE IN USE/ NO CONSTRUCTION MAIL/ FAX TO OTHER: CHANGE OF USE/ NO CONSTRUCTION Jt! APPLICANT'S SIGNATURE ~~/7 DATE ??// C/2-o!R I . - PERMIT INSPECTION HISTORY REPORT (CBC2018-0150) Permit Typo: BLDG-Commercial Application Dato: 03/19/2018 Owner: SHEA PROPERTIES MANAGEMENT CO INC Work Class: Tenant Improvement Issue Date: 08/30/2018 Subdivision: Status: Closed -Finaled Expiration Date: 08/19/2019 Address: 2662 Gateway Rd, 155 Carlsbad, CA 92009 IVR Number: 10197 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Relnspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency TCOok Yes BLOG-Plumbing Final Yes BLDG-Mechanical Final Yes BLOG-Structural Final Yes BLDG-Electrical Final Yes 02/2812019 02/28/2019 BLDG-Fina\ 084857-2019 Passed Andy Krogh Complete Inspection Checklist Item COMMENTS Passed BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes BLDG.Fire Final 083945-2019 Scheduled Cindy Wong Incomplete Checklist Item COMMENTS Passed FIRE· Building Final No February 28, 2019 Page 3 of: PERMIT INSPECTION HISTORY REPORT (CBC2018-0150) Permit Type: BLDG-Commercial Application Date: 03/19/2018 Owner: SHEA PROPERTIES MANAGEMENT CO INC Work Class: Tenant Improvement Issue Date: 08/30/2018 Subdivision: Status: Closed -Finaled Expiration Date: 08/19/2019 Address: 2662 Gateway Rd, 155 Carlsbad, CA 92009 IVR Number: 10197 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Relnspection Complete 12/19/2018 12/19/2018 BLDG-24 079354-2018 Failed Andy Krogh Reinspection Complete Rough/Topout Checklist Item COMMENTS Passed BLOG-Building Deficiency Insulation on all hot water lines No BLDG-44 079356-2018 Failed Andy Krogh Relnspection Complete Rough/Ducts/Dampe rs Checklist Item COMMENTS Passed BLDG-Building Deficiency Seismic straps, cleats No BLDG-97 Disabled 079355-2018 Passed Andy Krogh Complete Accessibility Checklist Item COMMENTS Passed BLDG-Building Deficiency Partial walk for sinks Yes 12/31/2018 12/31/2018 BLDG-24 080107-2018 Partial Pass Michael Collins Relnspectlon Incomplete Rough/Topout Checklist Item COMMENTS Passed BLDG-Building Deficiency Insulation on all hot water lines No BLOG-Building Deficiency Hot water line insulation Yes BLOG-33 Service 080109-2018 Cancelled Michael Collins Reinspection Complete Change/Upgrade Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG44 080108-2018 Partial Pass Michael Collins Reinspection Incomplete Rough/Ducts/Dampe ,. Checklist Item COMMENTS Passed BLDG-Building Deficiency Seismic straps, cleats No BLDG-Building Deficiency Straps at plenum, see card. Yes 01/03/2019 02/14/2019 BLDG-Fire Final 079676-2018 Failed Cindy Wong Relnspection Complete Checklist Item COMMENTS Passed FIRE-Building Final No 02/13/2019 02/13/2019 BLDG-14 083811-2019 Passed Andy Krogh Complete F rame/Steel/Boltlng/ Welding (Decks) 02/2012019 02/20/2019 BLDG-Final 084174-2019 Partial Pass Andy Krogh Relnspection Incomplete Inspection February 28, 2019 Page 2 of PERMIT INSPECTION HISTORY REPORT (CBC2018-0150) Permit Type; BLDG-Commercial Application Date: 03/1912018 Owner: SHEA PROPERTIES MANAGEMENT CO INC Work Class: Tenant Improvement Issue Date: 0813012018 Subdivision: Status: Closed -Finaled Expiration Date: 0811912019 Address: 2662 Gateway Rd, 155 Carlsbad, CA 92009 IVR Number: 10197 Scheduled Actual Primary Inspector Complete Date Start Date Inspection Type Inspection No. Inspection Status Relnspection 10/0312018 10/0312018 BLDG-21 071866-2018 Passed Andy Krogh Complete Underground/Underf loor Plumbing 10/09/2018 10/09/2018 BLDG-11 072192-2018 Passed Andy Krogh Complete FoundatlonfFtg/Pler s (Rebar) 10/22/2018 10/22/2018 BLDG-84 Rough 073560-2018 Passed Andy Krogh Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Do not lid hardlid without fire approval Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 10124/2018 10124/2018 BLDG-16 Insulation 073984-2018 Passed Andy Krogh Complete 10125/2018 1012512018 BLOG-14 074208-2018 Passed Andy Krogh Complete Frame/SteellBoltlng/ Welding (Decks) 1012912018 10(29/2018 BLDG-17 Interior 074355-2018 Failed Andy Krogh Reinspection Complete LathlOrywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No 1013012018 10/3012018 BLDG-17 Interior 074557-2018 Cancelled Andy Krogh Re inspection Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No 11/01/2018 11101/2018 BLDG-17 Interior 074791-2018 Passed Andy Krogh Complete LathlDrywall 1210512018 1210512018 BLDG-97 Disabled 077921-2018 Partial Pass Andy Krogh Relnspectlon Incomplete Accesslblllty Checklist Item COMMENTS Passed BLDG-Building Deficiency Partial walk for sinks Yes 12/13/2018 12113/2018 BLDG-33 Service 078669-2018 Falled Andy Krogh Reinspection Complete Change/Upgrade Checklist Item COMMENTS Passed BLDG-Building Deficiency No February 28, 2019 Page 1 of 3 '~~ ~ CITY Ol' RECORD COPY CBC2018-0150 2662 GATEWAY RD # 155 CARLSBAD Building Division INSPECTION RECORD BEVMO 7,856 SF Tl SHELL TO RETAIL [0 "'ISPECTION RECORD CARD WITH APPROVED ANS MUST BE KEPT ON THE JOB 2132622100 3/19/2018 th-ALL BEFORE 3:00 pm FOR NEXT WORK DAY INSPECTION 0 FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.carl.sbadca.gov/BuildlnrND CLICK ON "Request Inspection·· (} /l CBC2018-0150 DATE: 0 U If "YES" is checked below that Division's approval is required nricff_toyeq_uestin a Final Building Inspection. If you have any questions please call the applicable divisions at the phone numbers provided below. After all required approvals are signed off-fax to 760-602-8560. email to Q_I_Qgi11sp_~c;tiQns@._C:~_rJ~tJJ!dCa. ·_ ov or bring in a COPY of this card to: 1635 Faraday Ave., Carlsbad. IF MARKED 'YES", IT IS REQUIRED PRIOR TO ANY CONSTRUCTION STORM WATER PRECON MEETING REQUIRED 760-602-2725 Allow 24 hours IF MARKED "YES", APPROVAL REQUIRED PRIOR TO REQUESTING BUILDING Fire Prevention 760-602-4660 Allow 48 hours Planning/Landscape 760-944-8463 Allow 48 hours CM&I {Engineering Inspections) 760-438-3891 Call before 2 pm #34 ROUGH ELECTRIC/ EV CHARGER #66 MASONRY PRE GROUT #33 □ ELEC SERVICE #32OTEMPORARY □GROUT 0 WALL DRAINS #35 PHOTO VOLTAIC cl!n, TILT PANELS #38 SIGNS #11 PDUR STRIPS. ~----------+-----+-----I BLDG• FINAL #11 COLUMN FOOTINGS CODE -II MECHANICAL #14 SUBFRAME □ FLOOR O CEILING #41 UNDERGROUND DUCTS & PIPING #15 ROOF SHEATHING #44 □ DUCT & PLENUM □ REF. PIPING #13 EXT. SHEAR PANELS #43 HEAT-AIR COND. SYSTEMS #16 INSUIATION #18 EXTERIOR IATH #17 INTERIOR IATH & DRYWALL UNDERGROUND (11,12,21.31) .... ,. ....... .-. Date Date Date COPY OF CARO REQUIRED Inspector Ins ector Ins ector DRYWALL,EXTIATH, GAS TES (17,18,23) #22 □ SEWER & BL/CO □ Pl/CO #21 UNDERGROUN ASTE O WTR #24 T0P0UT □WASTE □WTR #27 TUB & SHOWER PAN #23 □ GAS TEST □ GAS PIPING #25 WATER HEATER #28 S0IAR WATER BLDG-FINAL CODE# POOLS #51 POOL EXCAV STEEL #52 PLUMBING -•1 ELEC / CONDUIT/ WIRING ) EQUIPOTENTIAL BOND ':,--, PREPIASTER / FENCE/ AIARMS #57 GUNITE Date • ROOF SH EATING, EXr SHEAR (13.15) #84 FRAME ROUGH COMBO (14,24,34,44) #85 T-Bar(14,24,34,44) BLDG· FINAL OCCUPANCY Date Ins ector A/S UNDERGROUND FLUSH A/S OVERHEAD VISUAL Ins ector A/S OVERHEAD HYDROSTATIC A/S FINAL F/A ROUGH-IN F/AFINAL FIXED EXTINGUISHING SYSTEM ROUGH-IN FIXED EXTING SYSTEM HYDROSTATIC TEST FIXED EXTINGUISHING SYSTEM FINAL BLDG·FINA_L ___ ····--------4------+-----+-"M:CE=D'-'IC::.:Ac:.L;:;GAccS:.:P_:_R=ES::.S:c:U:.:R:::E_:_TES::::.T_ ............. ~--4e------+------ MEDICAL GASl=INAL REV9/17 SEE BACK FOR SPECIAL NOTES Pro,ec1 BevMo pered M,nh Tran • Healthy Bu,ldngs # Reference/ System Lighting and HVAC 2 Roof Top Units Site Observation Report 1-10-19 Site Observation Report Observation Dnc:r1ptlon No Action Required: Lighting and HVAC dlst~bution and controls have been installed. Action Required: A missing grill on one of the RTUs. Page 1 of6 S.le Nltion eport # O■te of Srte V1111 Jan"8 10 2019 Plan / Sketch / Photo I Healthy Buildings Print Date: 1/11/2019 Project· BevMo Prepal'ed Minh Tran • Healthy Buildings # Refe,.nce / Syatem Exhaust Fan HVAC Labeling Site Observation Report 1-10-19 Site Observation Report Observation Oeacrfptlon Action Required: No power and control to the exhaust fan. and T earn to get this work done. Action Required: Mechanical sub to place labels on RTUs Site Observation Report.,. Date of Srte Visit Janua 10 2019 /~ GC to communicate with BevMo ~j •· Page 2 of6 Plan I Sketch/ Photo ( ► Healthy Buildings Print Oate: 1/11/2019 ProJOct BevMo Prepare<! Mtnh Tran -Healthy BUIidings # 6 Reference/ System Setting, -Progammable Thenno1tat1 CO2 Sensors Site Observation Report 1-10-19 Site Observation Report Observation OeacrlpUon No Action Required: Occupied and unoccupied achedulH and temperatures (1dj,) were set II per call out on p(ana. BevMo to adjust based on their operation hours. No Action ~quired: Verification of CO2 concentration levels. Per mechanical 1ublGC, BevMo/Team has requested and approved the change/location of CO2 sentor110 they e1n Mt up their C:00,ers ■nd configure ules areas. Page 3 of 6 Sita bservatlon Report#· Date or Site Visit. Janua 10 2019 Plan / Sketch / Photo ( . Healthy Buildings ·- Print Date: 1/11/2019 Site Observation Report Project BevMo Prepared Mmh Tran • Healthy Bu1ld1ngs # Reference/ SY9tem Observation Oeecrtptlon Domestic Hot Water Heater and No Action Required: Verification of domestic hot 'Miter heater system installation. Hot water piping ln1ul1tion ln1t1ll1tion insulation were found to be lnstal•d Sink in Sales Area Action Required: Faucet in the Sales Area was found to be leaking. Sije Observation Report 1-10-19 Page 4 of 6 Sile Observation Report # Date of Site Visit. Janua 10 2019 Plan I Sketch/ Photo I • Healthy Buildings Print Dale: 111112019 Project· BevMo Prepared Minh Tran • Healthy Buildings # 10 Reference/ System Lighting and Low Voltage S'Mtc:Ms In Salet ArH EM/ Inverter TetUng $ije Observation Report 1-10-19 Site Observation Report Observation Deacr1ptlon Action Required: Plate to be installed after all aWtches lnatalled. No Action Required: Verification of Inverter and emergency ltghting oper1lion, Page 5 of 6 Site t>servat,on Report#" Date of Site Visit Janua 10 2019 I • ' He althy Buildings Plan / Sketch I Photo Print Date: 1/11/2019 Project· BevMo Prepared Minh Tran • Healthy Buildings # Reference I System 11 Lighting Controls Site Observation Report Observation Oeacrlptlon No Action Required: Verification of lighting control system and Nghting schedule. Lighting levels and schedule cen be adjusted besed on BevMo operation schedule. O&M lralnl~lk lo be provided 10 BevMo staff by elec1rical sub. 12 Action Raqulred: Electrical aub to comptete the label and make some adjustments on primary zone of Lighting Control Box I Labeling dlytighllng controls as needed. Site Observation Report 1-10-19 Page 6 016 Site Observation Report 'I Date of Site VISrl Janua 10 2019 ( . He althy Buildings Pion I Sk.tch I Photo ----------------------------- Print Date: 111112019 LEED Commissioning Deficiency Tracking Sheet ... _ Project Name BevMo p,.,,_,wc1 by Minh Tran Hai.ti • 1-a u1H: (fPTI DIIK-.d d\lfltle fliMl>On.i Perform-• Tttlirc • (PCVI ~ed duriflt P,-e-,funnlo~ Tnllflt verlfiUlicNI • (PCI -Horded bv lh■ cont~or O(t _. Pr•FuRCClonal Chkkh'1 • !FOi Ob«.NJ.d • lhe rnult r1' • Fi.Id ObteN•tiMI,; ""Cock: IAJ Ac:«¢..:1 byOWnllf", !Cl CouiKtrd, fO)~ .kt1o11 t-t: !All Nthk.ct,l(,c!Mef, (GCJ Gent<,! ~r.«or, IHJ EIKtrk.11 wb, (CS) Con1,og Sub. (PS) PNmb4nlSub, IMSI MKhlnialSub. IOSJ O.~Sub, [TS) TA&, IOltl Ow'1"'r's bp, MVltftdOf ·--~ lnue Atul9)'tllm RdEqptlO luu• O..cf'lpUon Tachntoal Comment ftEIPON.SE I ACTK>N ITEMS • o, .. 1 1/10/19 RoofTop Unit Outside Air Grill A mllelng grill on one of the Roor Top Units. Mechanlca1 eub to install • grill. 2 1/10/19 RoofTopUnitt Lat>eHng No tabeJs on Root Top Unitt. Mach■nical sub lo P'aO& labels oo Roof Top Unitl, 3 1110/19 Programmab$e Thermoatn Labelng No labe• on pc'ogrammat»e thermoetata. Meohan;c.t 1Ub to place labels on l)fogrammable thennoetat1. Roof Top Units-Outside Ak Ow.Ide A'I Oltaide Air Dampers on Roof Top Units WMt not open~ or GC to chedi. -Mth both Meehan.cal sube to verffy if the 4 1/10/19 modulating. Tl Mechanioal Sub wn n<X demonetrttl~ thti Oampera Dampen ope(8tion due to bbiMy between Tl & Shell projeota. operation of outside air dampera, 5 1/10/19 Exhauat Fan lnatallatlon No power/controll were lnatalld lmplemented GC to check 'Nilh BevMo and Team and CX>Ol'dlnate with avbe to com~ete the lnttallatk>n. Sett• -Progranvnable Mechanical sub programmed ttte Mtttinga of occup!ed Ind Completed by Tl Mecf'lanloll Sub BevMo to adjust 6 1/10/19 Th&rmostltl Sett"l)I unoccupied hourt I tempertturet baaed on eall out on the Meehank:al &Ub has comP'eted the programming. based oo their butlneu hours.. rnechanlcal pfaM. 7 m0119 Sink In h Salea Area LNk LHk WH found on h Wik., the SalH ........ GC to coordina" wff\ f>1umbirv 8Ub ID ohedt and oorTWCt N --• 1110/19 Plall on sw+tchea In S.laa Arte IMtalatlon Uphting / l,.ow Vtwbl~ awit:hN ID bt oorf1Mt»d and • platll ID ba Subs ID pa.c. • plata on 1h11 owrriCM llc,h1hg and IOW 'l'OMge _...,_ ~• WMn inttaladon i. dc>nt. Eliec:ticcll SI.lb ~lld 1141 lltmp<WIII')' lighting echadulti from !5:00 S.vMo ID adjulll .... !Qhling achedule and 11,ghting law! beNd • 1/10/19 '""'""'-s.-AM 10 12:00 AM. El9c:trioal aub to pn:,vlda O&M n!Nng to Bloll'Mo on on lhalr bu.in.a hounl. O&M n lnlng to ba pn.wi(Md by EIKtrioal Sw ~oonlrOla. ,o 1/10/19 -eo,,,,.,. ....... E~I Sllb ID corrf)lell 1he lighting lavelt on clll)'lghting oontrnla Elamical Sub ID~-tome l'!'IOl'9 edjuttrnanta on ••ne.ded. clllyll0h1ltig oontroll •• nffdad. Pl•oe .. .,.,. on control boll. ~•10ft ... I tlNl\hy ......... vpdl•r«i .,.,. .... nufry 10 2019 ·-.. By FPT no MC No MC No MC v .. MC YN MC No MC No PC No EC No EC No EC '""'-i::..:111112019 LEED Commissioning Deficiency Tracking Sheet ·~ \ Healthy BuHd,ngs Project Project Name: BevMo Update No Prepared by-Minh Tran Date January 10. 2019 _, -11 ..... source: (FPTJ Oi5COWf<d dunne Functional Perfonnona, Testing• (PCVJ 01,cowr<d dunnc PfHunctlon•I Testlnc -flatlon. [PC! R-.d by th<! contractor on a PrHunctional Checklist -(FOJ Oi5COWf<d as th<! re>Ult ot a F1'!td Obse<votlon; lies Code: IA) Accepted by Owner, 1q COrrected, IOI Open; Adlon lly: IAEJ Archltoct/EncinN<, IGCJ -I Contractor, IESl Electrical Sub, ICSJ Controls Sub, (PS) P1umbln1 Sub, (MS( M«mnicol Sub, (OS) Oth<f Sub, (TSJ TAB, (Of!) Ownef', Rop, (VJ Vendor -...... Area /Syntm R.r/1:qptlO ...... Dncrlpllon Tedmlcal Comment RESPONSE I ACTION ITEMS Affects By • Date FPT 1 1/10/19 Roof Top Unit Outside />Jr Gil A missing grill on one of the Roof Top Units Mechanical sub to install a grill Complete no MC 2 1/10/19 Roof Top Units Labeling No labels on Roof Top Units Machanical sub to place labels on Roof Top Units Complete No MC 3 1/10/19 Programmable Thermostats Labeling No labels on programmable lhennostats Mechanical sub to place labels on programmable Complete No MC lhennostals Roof Top Units -Outside AJr Outside Mr Outside Nr Dampers on Roof Top Units were not opening or GC to ched< with both Mechanical subs to vefify if the 4 1/10/19 Dampers Dampers modulalilg. Tl Mechanical Sub was not demonstrate the operation of outside air dampers Complete Yes MC operation due to liability between Tl & Shell projects 5 1/10/19 Exhaust Fan lnstalalion No power/controls were inslaled/implemented GC to ched< with BevMo and Team and coordinate with Complete Yes MC subs to <X>fTlpiete the instalation Settings -Programmable Mechanical sub programmed the settings of oca,pied and Completed by Tl Mechanical Sub. BevMo to adjust 6 1/10/19 Themlostats Settings unoccupied hours / temperattKes based on cal out on the Mechanical sub has <X>fTlpleted the programming based on their business hours No MC mechanical plans 7 1/10/19 Sink in the Sates ma Leak Leak was found on the sink in the Sales P>rea GC to coordinate with P1umbing sub to check and com,ct the Complete No PC issue 8 1/10/19 Plate on Switches in Sales ma tnstallalion Lighting / Low Voltage switches to be coq,leted and a plate to be SUba to place a plate on the ovenide lighting and low ~ Complete No EC instaled swildles when ln&talation is done EJedrical Sub competed the temperary lighting schedule from 5:00 BevMo to adµ! the lighting schedule and lighting level based 9 1/10/19 Lighting Schedule Settings AM to 12:00 tw,. Electric:al sub to provide O&M training to BevMo on O&M trainng to be provided by Electric:al Sub No EC lighting a>ntrols. on their busineSS llouls 10 1/10/19 Lighting Controls Settings Eledrical Sub to complete the lighting levels on~ ccntrols Eledrical Sub to complete some more~ on Complete No EC •• needed daylighting a>ntrols as ,,,,__ Ptace labels on a>ntrol box ("'.nnv nl ~ Lw.18 loo 1-10-19 Page 1 of 1 Prtnt Date: 2/25/2019 ✓• EsG1I A SAFEbuilfCompany DATE: 5/30/2018 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2018-0150 PROJECT ADDRESS: 2662 Gateway Rd. PROJECT NAME: BevMo Tenant Improvement SET: II □ APPLICANT ,_P-.J,l.JRIS. [8J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. -, D The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: [8J EsGil staff did not advise the applicant that the plan check has been completed. D EsGil staff did advise the applicant that the plan check has been completed. Person contacted:,----no Telephone#: -(0&(1/ ) Email: Date contacted: Mail Telephone 0 REMARKS: By: Jason Pasiut EsGil Fax In Person Enclosures: 5/21/2018 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 DATE: 3/27/2018 JURISDICTION: Carlsbad PLAN CHECK#.: CBC2018-0150 ✓• EsG1I A SAFEbui!t Company SET: I PROJECT ADDRESS: 2662 Gateway Rd. PROJECT NAME: BevMo Tenant Improvement 0 APPLICANT /a JURIS. D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [g] The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [g] The applicant's copy of the check list has been sent to: Rob Boucke 0 EsGil staff did not advise the applicant that the plan check has been completed. [g] EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Rob Boucke Telephone#: 720-529-8768 Date contacted: 3/2, /it"(by:~ Email: rboucke@mcgarchitecture.com ~ Telepho;;;-_!ax In Person 0 R RKS: By: Jason Pasiut EsGil 3/20/2018 Enclosures: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 ~arlsbad CBC2018-0150 3/27/2018 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK#.: CBC2018-0150 OCCUPANCY: M, S2 TYPE OF CONSTRUCTION: VB ALLOWABLE FLOOR AREA: within SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 3/19/2018 DATE INITIAL PLAN REVIEW COMPLETED: 3/27/2018 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad USE: Retail Sales ACTUAL AREA: 7 ,856sf STORIES: 1 HEIGHT: unchanged OCCUPANT LOAD: 114 DATE PLANS RECEIVED BY ESGIL CORPORATION: 3/20/2018 PLAN REVIEWER: Jason Pasiut This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list {or a copy} where each correction item has been addressed, i.e., plan sheet number. specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. C.arlsbad CBC2018-0150 3/27/2018 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Jason Pasiut PLAN CHECK#.: CBC2018-0150 DATE: 3/27/2018 BUILDING ADDRESS: 2662 Gateway Rd. BUILDING OCCUPANCY: M, S2 BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier 7856 46.51 Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction C.Ode cb By Ordinance ---------------, 1~~7 u~c B~~~!ng Permit Fe~--~_.} Type of Review 0 Complete Review Reg. VALUE Mod. D Structural Only D Repetitive Fee ------;-i Repeats _, □ Other D Hourly EsGII F- 1-----------11 Hr. @ * Comments: ($) 365,383 365,383 $1,570.36! $1,020.731 $895.111 Sheet 1 of 1 Carlsbad CBC2018-0150 3/27/2018 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring IlYQ corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. • WALK IN COOLER 1. Provide the manufacturer standard plans and installation instructions/listing information for the cooler walls and refrigeration equipment being proposed. CMC 935. a) Show electrical loads and show that the equipment meets UL 471 and 427. b) Show connection details for corners and roof including fasteners. c) Show foam thickness and flame-spread information. 2. Show location of indirect drain / floor sink and detail drain pipe size and required airgap. CPC418.4. 3. Refrigerated Spaces that are less than 3,000 square feet shall meet the requirements of the Appliance Efficiency Regulations for walk-in coolers or freezers contained in the Appliance Efficiency Regulations (California Code of Regulations, Title 20, Sections 1601 through 1608). Note on the plans whether this installation meets these requirements. CEC 120.6 (a) 4. Will there be or is there a floor drain within the cooler? CPC 801.3.2. 5. Please note or show that all electrical penetrations into the cooler shall be sealed per section 300-7 of the NEC. 6. Please provide a roof plan showing the location of the new condensing unit. • STRUCTURAL 7. Please provide Special Inspection program information for SI that may be proposed for the racks that exceed 8'. CBC 1705.12.7. Nextpage Carlsbad CBC2018-0150 3/27/2018 • ELECTRICAL 8. A GFCI protected receptacle outlet is required within 25 feet and on the same level as the mechanical equipment (heating, air-conditioning, and refrigeration equipment). Please include on the plans. NEC 210.63. • END OF REVIEW To speed up the review process, please note on this list (or a copy} where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes. please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: □ Yes □ No The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Jason Pasiut at Esgil. Thank you. Sl'ECIAL PRODUCTS TANK.SUPPORTS MACHINERY RACICBLOOS SHEDS MEZ1.ANtNES F0011NOS CONVEYORS TALL SUPPORTS HEADElt STEEL SORT PLATFORM PICK MODULES ROOFVERD'lCATION I 130 E. Cypress St •• Q.~ I!::::=#=~~~~~~ l\lATEIUt.LHAND RING STORAGE RACKS SELECTIVE DRIVE-IN PUSH BACK FLOWP.ACK CANTILEVER OTHER SERVICES SEISMIC ANALYSIS PERMIT ACQUISITION EGR.ESS PLANS ST ATE A!'PROV A!.S PRODUCT TES'nNG Licensed In All 50 States LIGHT DUTY STORAGE FIXTTJRES FOR BevMo! 2662 GATEWAY ROAD., SUITE #155 CARLSBAD, CA 92009 JOB #:18-0484 SALE. FATEEN, P.E. 315/2018 EXPIRES OEC 3 l 2019 SHELVING METAL METALJWOOD MOVABLE OONDOLAS LOCKW CAlWALKS Covina CA 91724 TEL : 909-869-0989 SPECIALS PRODUCTS Sl!UITLES VLM CAROUSELS VRC MODULAR. omCES FENCES ,,!>l ""' •· . '"' cec2.o ,s,-o,so SEIZMIC INC. PROJECT BEVMOI FOR BEVMO! MATERIAL HANDLING ENGINEERING TEL: (909) 869--0989 / FAX: (909) 869--0981 1130 E CYPRESS STREET, COVINA, CA 91724 SHEET NO. 2 CALCULATED BY TB DATE 3/5/2018 MULTIFUNCTION UNIT ANALYSIS PROJECT SCOPE: PROVIDE SEISMIC ANALYSIS DF LIGHT DUTY STORAGE RACK TO CONFORM TO THE REGULATIONS SET BY THE 2016 CBC. CRITICAL CONFIGURATION ANALY2ED. PARAMETE : THE LIGHT DUTY STORAGE FIXTURE USED IN THIS PROJECT CONSISTS OF GONDOLA TYPE SHELVING COMPONENTS. THE STABILITY OF THE SHELVING DEPENDS ON THE BRACED FRAME (PEG BOARDS AND HORIZONTAL BRACES) ALONG THE LONGITUDINAL DIRECTION. ALONG THE TRANSVERSE DIRECTION, THE SHELVING RELIES ON A CANTILEVER FRAME SYSTEM FOR STABILITY. -SEISMIC -MAIN STEEL • ANCHOR -SLAB -SOIL V= (2/3) x Fax Ss x Ix Ws / R Fy = 36,000 PSI 3/8" 121 x 2-5/16" MIN. EMBED. HILT! KB-TZ WEDGE ANCHOR (ICC ESR-1917) 5 IN x 2,500 PSI 500 PSF ---N.ib ,✓ '~ I , ' , PARllClE BOARD SHELF SHELVING COMPONENTS: 1 = UPRIGHT Con ur ti ns: 48"W x 24"0 x 102"H 36'W X 18"0 X 102"H Levels 6 s 3 = ANCHORS 4 = ANCHOR PLATE 7 = BASE DECK 9= REAR BEAM 10 = FRONT BEAM 11 = SUPPORT BEAM 14 = BASE DECK CONNECTOR 15 = SHELF SUPPORT Loads lOOLB/LVL 100 LB/LVL CRITICAL SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869--0989 / FAX: (909) 869-0981 1130 E CYPRESS STREET, COVINA, CA 91724 PROJECT FOR BEVMOI BEVMOI SHEET NO. 3 CALCULATED BY TB DATE 3/5/2018 LOADS & SEISMIC DISTRIBUTION: MULTIFUNCTION UNIT ANALYSIS V = (2/3) x Fax Ss x Ix Ws / (R) TYPICAL MULTI-FUNCTION FIXTURI: F"" Wl~ -ffi .. Ss = 1.039 ~ I Fa= 1.0844 Rgond. = 3 I= 1 Rtrans.multi. = 4 II SDS = 0.751127733 Rlong. = 4 .,_.. n DL = 10 LB rr LL-cant. = 100 LB #ofLVLS = S e)TYP. LL-top= 100 LB # of LVLS = 1 c:= GONQOLA Wg = (0.67*wLL+wDL) x #LVL ,. •" """"' ""-"· = 385 LB ''""' = -,, V(max) = (2/3) x 1.0844 x 1.039 x 1 x Wg / (R ) -= 0.751 W/R I 1; I -' MULTI-UNIT top LEVEL ' , ... Wm= (0.67 x wLL+wDL) x #LVL Iii '@ = 77LB " mONTIIEW ...... V(min) = (2/3) x 1.0844 x 1.039 x 1 x Wm/ (R) = 0.75 W/R Vtrans.(g) = 0.250 W <==Wg+Wm Vtrans.(m) = 0.188 Wg = 116 LB = 7 LB INTERIOR COLUMNS ARE TAKING HALF THE LOADS Vlong. = 0.188 w <==Wg+Wm WITH REGARDS TO THE TOP LEVEL ONLY AND THE = 87LB REST BY THE (2) EXTERIOR COLUMNS. LEVEL hx wx hxwx Filtrans,J FJ!lono.l Movt. l 19.3 IN 110 LB 2,118 IN-LB 7LB 5 LB 127 IN-LB 2 33.31N llOLB 3,658 IN-LB llLB 9 LB 378 IN-LB 3 47.31N 110LB 5,198 IN-LB 16 LB 12 LB 763 IN-LB 4 61.31N llOLB 6,738 IN-LB 21LB 16LB 1,283 IN-LB 5 75.3 IN llOLB 8,278 IN-LB 261B 19 LB 1,936 IN-LB 6 102.0 IN 110 LB 11,220 IN-LB 35 LB 26 LB 3,558 IN-LB 660LB 37.208 IN-LB 116 LB 87 LB 8,046 IN-LB TRAN~VERSE ANALYSIS: d = 18.0 IN Ptotal(g) = 385 LB Ptotal(m) = 60 LB <== Wm/4 + V(m) x 102/dshelf Mcol(g) = Movt = 8,046 IN-LB Mcol(m) = 737 IN-LB SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 1130 E CYPRESS STREET, COVINA, CA 91724 COLUMN ANALYSIS (TRANSVERSE) Back Post SECTION PROPERTIES BASED ON THE EFFECTIVE SECTION. P= (1+-0.115.,)DL+-0.7S•(l+-0.14SoslPL = S62LB M= 0.7S•0.7*Mselsmlc = 4,224 IN-LB Kxl.x/rx = 2.1 *102 IN/1.07 IN = 200.2 <=== (Kl/r)max Kyly/ry = 1 *16 IN/0.6 IN = 26.7 Fe= n•2E/(KL/r)max•2 = 7.3 KS! Fy/2= 18.0 KS! SINCE, Fe < Fy/2 THEN, Fn= Fe FLEXURE = 36 KSl*[l-36 KSl/(4*7.3 KSI)] = 7.3 KS! Pn= Aeff*Fn = 6,975 LB Oc= 1.92 Pa= Pn/Oc = 6975 LB/1.92 = 3,633 LB P/Pa= 0.15 > 0.15 CHECK: P/Pa + (Cmx•Mx)/(Max•µx) S 1.00 P/Pao + Mx/Max S 1.00 Pno= Ae*Fy = 0.96 !N•2 *36000 PSI = 34,560 LB Pao= Pno/Oc = 34560 LB/1.92 = 18,000 LB Myield=My= Sx*Fy THUS, = 0.83 IN•3 • 36000 PSI = 29,880 IN-LB Max= My/Of = 29880 IN-LB/1.67 = 17,892 IN-LB Per= n•2El/(KL)max•2 = n•2•29500 KSl/(2.1 *102 IN)•2 = 6,917LB PROJECT FOR SHEET NO. CALCULATED av DATE BEVMO! BEVMOI 4 TB 3/5/2018 SECTION PROPERTIES Aeff = 0.960 !N•2 Ix= 1.090 IN'4 Sx = 0.830 !N•3 rx = 1.070 IN ly = 0.340 IN'4 Sy= 0.380 IN'3 ry = 0.600 IN Kx = 2.1 Lx = 102 IN Ky= 1.00 Ly= 16.0 IN Fy= 36 KSI E= 29,500 KS! Of• 1.67 Cmx= 0.85 Cb= 1.0 µx= {1/(1-(0c*P/Pcr)]}"-l = {l/[1·{1,92*0 LB/6917 LB)]}"-1 = 1.00 (562 LB/3633 LB)+ (0.85*4224 IN-LB)/(17892 IN-LB*1) = (562 LB/18000 LB)+ (4224 IN-LB/17892 IN-LB)= 0.36 0.27 < 1.00, OK < 1.00, OK SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 1130 E CYPRESS STREET, COVINA, CA 91724 COLUMN ANALYSIS (TRANSVERSE) Front Post SECTION PROPERTIES BASED ON THE EFFECTIVE SECTION. P. 60 LB M= 5161N-LB KxlJ</rx= 2.1•102 IN/0.77 IN = 278.2 KyLy/ry = 2.1 *102 IN/0.611 IN = 350.6 <== (Kl/r)max Fe= n•2E/(KL/r)max•2 = 2.4 KSI Fy/2= 18.0 KSI SINCE, Fe < Fy/2 THEN, Fn= Fe FLEX RE = 36 KSl*[l-36 KSl/(4*2.4 KSI)] = 2.4 KSI Pn= Aeff*Fn = 854 LB Cle= 1.92 Pa= Pn/Oc = 854 LB/1.92 = 445 LB P/Pa= 0.14 < 0.15 CHECK: P/Pa + Mx/Max s 1.00 Pno= Ae*Fy = 0.361INA2 *36000 PSI = 12,978 LB Pao= Pno/Oc = 12978 LB/1.92 = 6,759 LB Myield=Mr-Sx*Fy THUS, = 0.244 IN•3 • 36000 PSI = 8,795 IN-LB Max= My/Of = 8795 IN-LB/1.67 = 5,266 IN-LB Per= n•2El/(KL}max•2 = n•2*29500000 PSl/(2.1*102 IN)•2 = 1,385 LB PROJECT FOR BEVMOI BEVMOI SHEET NO. S CALCULATED BY TB DATE 3/5/2018 P. SECTION PROPERTIES µx= {1/[1-{0c*P/Pcr)])A-1 Aeff = 0.361 IN•2 Ix= 0.218 IN•4 Sx = 0.244 IN•3 rx= 0.770 IN ly = 0.135 IN•4 Sy = 0.149 IN•3 ry = 0.611 IN Kx = 2.1 Lx = 102.0 IN Ky= 2.1 Ly= 102.0IN Fr-36 KSI E= 29,500 KSI Clf= 1.67 Cmx= 0.85 Cb= 1.0 = {1/[1-(1.92*60 LB/1385 LB)])A-1 = 0.92 (60 LB/445 LB)+ (516 IN-LB/5266 IN-LB)= 0.11 < 1.00,OK SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909} 869-0989 / FAX: (909} 869-0981 1130 E CYPRESS STREET, COVINA, CA 91724 BASE AND ARM ANALYSIS ARM CHECK: CHECK TENSION CAPACITY: ARM SPAN = 22.0 IN LOAD = 110 LB/LEVEL M = LOAD x (ARM SPAN/2} = 110 LB/LEVEL x 22 IN/2 = 1,210 LB-IN ASSUME ONLY THE TOP CLIP IN TENSION TENSION CAPACITY = T = 0.6Fy x A = 0.6 x 36000 PSI x 0.09 IN'2 = 1,944 LB MOMENT CAPACITY = T x d = 1944 LB x 1.125 IN PROJECT BEVMO! FOR BEVMOI SHEET NO. 6 CALCULATED BY TB DATE 3/5/2018 = 2,187 LB-IN > 1210 LB THEREFORE OK CHECK FOR SHEAR CAPACITY: Varm = LOAD/2 = (n'2E/(Kl/r}max•2 + }/ 2 = S5 LB/LEVEL SHEAR CAPAOTY = 0.4Fy • A = 0.4 x 36000 PSI X 0.09 IN'2 = 1,296 LB > SS LB THEREFORE OK Mcol(total) = 4,224LB-IN fb = Mcol(total}/Sx = 4224 LB-IN/ 1.18 IN'3 = 3,580PSI Fb = 0.6 x 36000 PSI = 21,600PSI fb/Fb = 3580 PSI / 21600 PSI = 0.17 < 1.00 THEREFORE OK --..,.. A= 0.090 IN'2 Fy = 36,000 PSI d = 1.125 IN Sx = 1.18 IN•3 Fb = 36,000PSI SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 1130 E CYPRESS STREET, COVINA, CA 91724 MULTI-FUNCTION SHELVING ANALYSIS CONNECTION CHECK Mconn = Vcol • H = 737 LB-IN SHEAR CAPACITY OF TAB: Pallow = 0.4Fy • AREA = 0.4 X 36000 PSI x 0.0788 IN•2 = l,134LB Mallow= Pallow • dist. = ((1134 LBx4 IN)+ 1134 LB x2 IN /2) = 5,670 LB-IN > 737 LS-IN THEREFORE OK BEAM CHECK Mbeam(seis) = 737 LB-IN Mbeam(stat) = wl•2/8 w = 77 LB/LEVEL = 0.802 LB/IN Mbeam(stat) = 0.802 LB/IN x 48IN•2 / 8 = 231 IN-LB Mbeam(total) = Mbeam(stat) + Mbeam(seis) = 968 IN-LB fb = Mbeam(total)/Sx = 968 LB-IN/ 0.894IN•3 = 1,083 PSI Fb= 0.6x Fy = 21,600 PSI lb/Fb= o.os < 1.0 THEREFORE OK PROJECT BEVMOI FOR BEVMO! SHEET NO. 6 CALCULATED BY TB DATE 3/5/2018 Fy = 36,000 PSI AREA OF TAB= 0.0788 IN•2 Sx = 0.8940 IN•3 LENGTH OFTAB = 4.0 IN LONGTITUDINAL LENGTH OF BEAM= 48.0IN SEIZMIC INC. MATERIAL HANDLING ENGINEERING TEL: (909) 869-0989 / FAX: (909) 869-0981 1130 E CYPRESS STREET, COVINA, CA 91724 OVERTURNING ANANLYSIS FUU Y LOADED: Puplift = [(OMovt-0.9*Mst) / d] x # of occurrence = (116091-0.9*4158] IN-LB/ 18 IN) x 1 = 686 LB INTERACTION EQN. PER 4.2.Z OF ICC ESR-1917 (686 LB/ 1580 LB) + (58 LB/ 1800 LBJ = TOP LOADED: Vtop = 34 LB LEVEL hx wx hxwx 1 19.3 IN 10 LB 193 IN-LB 2 33.3 IN lOLB 333 IN-LB 3 47,3 IN 10 LB 473 IN-LB 4 61.3 IN 10 LB 613 IN-LB 5 75.3IN 10 LB 753 IN-LB 6 102.0 IN 87 LB 8,874 IN-LB 11,237 IN-LB Puplift = [(OMovt -0.9*Mst) / d] x # of occurrence = ([6327 IN-LB -0.9*1233 IN-LB)/ 18 IN) x 1 = 290 LB INTERACTION EQN. PER 4.2.2 OF ICC ESR-1917 [290 LB/ 1580 LBJ + (34 LB/ 1800 LBJ = PROJECT FOR BEVMOI BEVMO! SHEET NO. 7 CALCULATED BY TB DATE 3/S/2018 ALLOWABLE TENSION = 790 LB ALLOWABLE SHEAR= 900 LB # OF ANCHORS/ B.P. = 2 d = 18.0 IN # OF OCCURRENCE = 1 ANCHOR AT EVERY BAY O= 2 0.47 < 1.2 THEREFORE OK Fl(trans.) A(long.) Movt. lLB 0 LB 11 IN-LB l LB lLB 34 IN-LB lLB lLB 68 IN-LB 2LB lLB 115 IN-LB 2 LB 2 LB 173 IN-LB 27LB 21LB 2,763 IN-LB 34 LB 26 LB 3,164 IN-LB 0.19 < 1.2 THEREFORE OK ,. SAN DIEGO REGIONAL OFFICE USE ONLY -. ;; RECORD ID I HAZARDOUS MATERIALS PLAN CHECK I . . 1.\·· I I QUESTIONNAIRE BP DATE Business Name Business Contact Telephone I Beverages & Morel (dba BavMol) Carl Laughlin 925.609.6152 APNt ProtCI Addn,ss City State Zip Code 26 2 Gateway Road • Suite #155 Ca~sbaa CA 92009 213-262-09-00 Mailing Address City State Zip Code Plan FIie# 1401 WILLOW PASS ROAD, STE 900 CONCORD CA 94520 Project ContlCI Applicant E-mail Teleph!)ne# ..... --- Rob Boucke (c/o MCG Architecture\ rboucke""~architecture.com 720.529.8768 x514 The lotlowln untlona re 1911111 tho facl I 1clivltle1, NOT the 1pectflc project dncrlptlof:\ C::: \.., '-·· l V 1.-LJ p Illy' : n cate r ng t tem, r your iness use, process. or ston, any o t e applicant must contaet the fin, Protaetlon Agency with Jurladldlon pnor to plan submittal. Occupancy Rating: Mercantile F1clllty'1 Squirt Footagt (lncklding proposed projeCI): 7,856 Sq Ft. 1. EicplosiYe or Blasting Agents 5. Organic Peroxides 9. Water Reaet1ve1 2. Compn,ssed Gases 6. Oxidizers 10. Cryogenics 13. ~ .. ~~-~:,;::~~~\~~~~ 14. ~- 3. Flammable/Combustible Liquids 7. Pyrophorlc$ 11. HlghlyToldcorToldc Materials 15. None of These. 4. Flammable Solids 8. Unstable ReaCIIYes 12. Radloactlves ques ns yes, app ,cant must contact unty o n go 1 , an OlegO, CA 92123. can (858) 50~700 prior to the Issuance of a building pannlL FEES ARE REQUIRED Project Completion Data: Jan. 2019 Expected Date of Occupancy: Feb 2019 YES NO (for new conatructlon or n,modeBng projeclil) 1. D l!D Is your buSlnesa listed on the n,ver1eslde of thla form? (check an that apply). 2. D l!D WIit your businesa dispose of Hazardous Substances or Medical Wasta In any amount7 3. D 12:1 WIii your business stOrt or handle Hazanlous Substances In quantlties gn,ater than or equal to 55 gallons, 500 4. D 5. □ 8. D 7. □ a. D pounds and/or 200 cubic feet? lXI WIit. your bUBiness ston, or hlndle carctnogens/raproduetlve toJdns In any quantity? 12:1 ""111 yo..-business I.A an e,dsflntl or Install an underground storage tanl<? li1l Will you, blfslnen store or handle Regulated Substances (CalARP)? i WIH your bullnesa use or lnstaH a Hazardous Waste Tank System (fdle 22, Articie 10)? .., VWI your busln88S aton, petroleum In tanks or containers at yo..-facility with a total fadtlly alorage capacity equal to or n,ater than 1,320 allons? CatWomla's Above ound Patroleum Star e Act • 0 CalARP Exempt lritiall 0 CalARP Required tnitilll 0 CalARP Complete 1nitia, P I· DIE UNTY Al POLLUTI N CONTROL IS IC D : Any YES' anlWlr n,qulrM a stamp from APC. D 10124 Old Grove Road, San ego, . (' stamp n,qu,rid If Q1 Yes .lll!I Q3 Yes .lll!I Q4-Q8 No]. The following questions an, Intended to Identify the maJonty air on ossues at the p annlng stage. Projects may n,quln, additional measures not identified by these questions. For comprehensive requirements contact APCO. Residences are typically ...,mpt, except -those with man, than one building' on the property; slngle building• with mon, than fOII' dweWng units; townhornes; condos; mixed-commercial use; dallblrata bums; resldencH forming part of a larger project. ['Excludes garages & amall outbuildings.] YES NO 1. D Kl Will the project dlstllll 180 squan, feet or m0rt of existing building matelials? 2. D ll!I WIit any load supporting structural membl11 bl n,moved? NotlllcaUon may bl n,qulred 1 O working days prtor to commencing demollion. 3. O O (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been perfonned by a Certified Asbestos Consultant or Sile Surveillance Technician? 4. 0 0 (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey mutts, will the project disturb any asblslol containing material? NotlflcaUon may bl required 10 working days prior to commencing asbestos n,moval. 5. □ e. D \XI VWI the project or associated construetlon equipment emit elr contaminants? See the reverse aide of this form or APCD factsheet (www.sdapcd.0(90nfol(acls{pem1lts.pdn for typlcal equipment requiring an APCO panntt. 0 (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construetlon equlpmern be located within 1,000 feet of a school bounda Briefly describe business actMtlea: Briefly describe proposed project: BY: t of my knowledge and belief t e responses made hen,ln an, true and colT8Ct. ' Cht!Jr'1I 0,N =s1:-n-.a7ture-o-:f o=wner--or-:Au-:th:-orlz-:-ed-.--:-•-n-:-t --- FOR OFFICAL USE ONLY: DATE: I I g 1-:J-f /'y Date EIEMl'TOR NO FURTHER INfOIUAATION R!QUllll!D Rl!LW!O FOR BUI.DING PfftlllT IUT NOT FOR OCCUPANCY RILEAIEO FOR OCCUPANCY COUNTY-HMO' APCO COUNTY-HMO APCO COUNTY-HMO APCO • A stamp In this box Al!ll! 8ll8ll1PIS businesses from completing or updating • Hazardous Materials Business Plan. Other permlttlng requln,ments may still apply, ELISE ROTHSCHILD Director ., .. ~ <!Countp of ~an 1!lie~o DEPARTMENT OF ENVIRONMENTAL HEALTH FOOD AND HOUSING DIVISION P.O. BOX 129261, SAN DIEGO, CA 92112-9261 Phone: (858) 505-6659 FAX: (858) 505-6824 1 (800) 253-9933 www.sdcdeh.org AMY HARBERT Assistant Director PLAN APPROVAL SHEET DBA:BEVMO DA fE: 6/20/18 SITE: 2662 GATEWAY RD #155 CARLSBAD 92009 BUSINESS OWNER: SAA PC #: DEH20 l8-FFPP-009353 Plans are approved contingent upon the following: 1) Department of Environmental Health -Food and Housing Division {DEH-FHD) stamped plans shall be printed on a minimum 11" by 17" size paper to scale. Ensure each sheet is the same size and legible. A paper copy of the plans must be maintained at the jobsite to construct from and available for the Specialist to review at the time of your inspections. 2) Changes to equipment layout, menu, or application must be submitted for approval. Chai;ges made without approval will make the plan approval null and void. 3) Obtain local Building Department and all applicable agencies permits and approvals PRIOR TO FINAL INSPECTION AND APPROVAL TO OPERATE BY TIIlS DEPARTMENT. 4) All food and utensil-related equipment shall be ce1tified to applicable sanitation standard~ by an ANSI accredited testing agency. 5) Upon completion of 50%-80% of construction, call (858) 505-6660 to schedu le a mid-in~pection. In lieu of a plumbing inspection by DEH, ensure that the plumbing is constructed to these standards: a. Floor sinks shall be installed ½ exposed and equipped with an appropriate grill cowr if no access is provided for cleaning. b. Drain lines shall slope ¼" per foot, shall not exceed 15' in length and shall terminate a minimum of I" above the floor sink with a legal air gap or otherwise approved by the enforcing agency. Drain lines shall not intersect walkways or door ways. c. No condensate drainage of any kind can drain to the mop sink. d. 3-co·mpartment sinks, preparation sinks, dump sinks, and any other plumbed equipment must drain indirect to a floor sink. e. Grease traps/interceptors, if required by the local waste water authority must be loc.1ted outside of the food preparation, food storage, or warewashing areas. f. Floor surfaces must be sloped I :50 to required floor drains. g. Conduits of all types shall be installed within walls as practicable. When otherwise i.1 stalled, they shall be mounted or enclosed in a chase so as to facilitate cleaning. 6) Owners and/or operators must pass an approved and accredited Food Safety Ce1tification course. Proof of successful completion of this course is to be furnished at the final inspection. 7) All equipment is to be in place and functional. At the time when the final inspection is requested, tbe facility shall have all utilities operational and all refrigeration shall have an ambient air temperature of38°F or below .ind shall be equipped with a thermometer accurate to+/-2°F in lhe warmest section of the unit. 8) Seal all cracks, gaps and crevices in counters, cabinets, around metal flashing, sink back splashes, around pipes and cbnduits with silicone sealant. 9) AN AIR BALANCE REPORT IS REQUIRED IF THE FACILITY HAS VENTIL1, TION HOODS 10) ANY FOOD PROCESSING AREAS MUST BE COMPLETELY ENCLOSED. PERABL WALL PANELS GARAGE ROLL-UP DOORS OR OTHER MEANS OF RE1'1> ~RI NOT FULLY ENCLOSED ARE NOT APPROVED. 11) Be advised a licable ·urisdiction re uirements that result in chan Department of Environmental Health plans. Plans reviewed by: C. PENN, REHS revisions to the CALL (858) 505-6660 AT LEAST 10 WORKING DAYS IN ADVANCE TO SCHEDULE MID AND FINAL INSPECTIONS. A FINAL INSPECTION MUST BE CONDUCTED AND AN ENVIRONMENT AL HEAL TH PERMIT SHALL BE ISSUED PRIOR TO OPENING AND OPERATING THIS FOOD ESTABLISHMENT. "Environmental and public health through leadership, partnership and science"