HomeMy WebLinkAbout2667 CAZADERO DR; ; CB042527; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 07-16-2004 AA.X Electrical Permit Permit No: CB042527 Building Inspection Request Line (760) 602-2725 Job Address: 2671 CAZADERO DR CBAD Permit Type: ELEC Status: ISSUED Parcel No: 2154600300 Lot #: 0 Applied: 06/24/2004 Entered By: KMT Reference #: Plan Approved: 07/16/2004 Issued: 07/16/2004 Project Title: ERICKSON RES- INSTALL SOLAR Inspect Area: PHOTOVOLTAIC ELEC SYSTEM Applicant: Owner: CARLSON SOLAR INC. ERICKSON GREGORY A SUITE 221 2671 CAZADERO DR 43430 EAST FLORDIA AVE 92544 CARLSBAD CA 92009 909-927-0782 Electric Issue Fee $10.00 Single Phase per AMP 0 $0.00 Three Phase per AMP 0 $0.00 Three Phase 480 Per AMP 0 $0.00 Remodel/Alteration per AMP 0 $0.00 Remodel Fee $0.00 Temporary Service Fee $0.00 Test Meter Fee $0.00 Other Electrical Fees $110.00 Additional Fees $0.00 TOTAL PERMIT FEES $120.00 Total Fees: $120.00 Total Payments To Date: $0.00 Balance Due: $120.00 <$738 07/16/04 0002 01 02 FINAL APPROVAL **• CLEARANCE PERMIT APPLICATION CITY OF'CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK EST. VAL. Plan Ck. Deposit Validated y Date Address (include Bldg/Suite #) l. \^A*L. Business Name (at this address) Legal Description Lot No.Subdivision Name/Number Unit No.Phase No.Total # of units Assessor's Parcel #Existing Use Proposed Use SQ. FT.#of Stories of Bedrooms # of Bathrooms Name Address City State/Zip Fax* (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged emption. Any violation of Section 7031 .5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars I$500]). State License # i & mAddress License Class City ' " State/Zip City Business License # Telehone # Designer Name State License # Address City State/Zip Telephone Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is teued. My worker's compensation insurance carrier and policy number are: Insurance Company ^~f-A-^~jG r~~(jA/& Policy No. -fr/j^-JLJSaT Expiration Date / (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) Q CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure^prorkers' compensation coverage n unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000>^fe*'ddition^lo the cost of compensation, damages as provided for in Section 3706 of the Labor code^interest and attorney's fees. SIGNATURE ^Y^^f^f^^A/^^ DATE fc/£.'2*l0& hereby affirm ihSt I aufexempt from the Contractor's License Law for the following reason: Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). n I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES QNO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): PROPERTY OWNER SIGNATURE DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 26505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES Q NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097{i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit Is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not comrnencefLwfthin 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commepcetfjei^ periodjDf 180 days (Section 106.4.4 Uniform Building Code). /• APPLICANT'S SIGNATURE DATE WHITE: File YELLOW: Applicant PINK: Finance City of Carlsbad Bldg Inspection Request For: 08/02/2004 Permit* CB042527 Title: ERICKSON RES-INSTALL SOLAR Description: PHOTOVOLTAIC ELEC SYSTEM Inspector Assignment: TP 2671 CAZADERODR Lot Type: ELEC Sub Type: Job Address: Suite: Location: APPLICANT CARLSON SOLAR INC. Owner: ERICKSON GREGORY A Remarks: Phone: 0000000000 Inspector: Total Time: CD Description 39 Final Electrical Requested By: MARY Entered By: ROBIN Act Comment Associated PCRs/CVs Inspection History Date Description Act Insp Comments 07/29/2004 39 Final Electrical NS TP 07/26/2004 39 Final Electrical NR TP OWNER NOT AWARE OF WORK DONE WANTED PERSON REQUESTING INSP. IDENTIFIED EsGil'Corporation In tfartnersfiip witfi government for (BuiCcfing Safety DATE: 7/13/04 Q APPLIQANT JURIS; JURISDICTION: Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 04-2527 SET: II PROJECT ADDRESS: 2671 Cazadero Drive PROJECT NAME: Erickson Residential Solar The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person X REMARKS: The applicant to replace the existing single line diagram with "clean copies" matching the attached (faxed) single line to all permitted sets and add the subpanel location to the plan site plan (as clouded) to outstanding sets, By: Eric Jensen Enclosures: Esgil Corporation D GA D MB D EJ D PC Fax/7/12 tmsma.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 EsGil Corporation In Partnership witR government for <Bui&fing Safety DATE: 7/7/O4 Q APPLICANT JURISDICTION: Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 04-2527 SET: I PROJECT ADDRESS: 2671 Cazadero Drive PROJECT NAME: Erickson Residential Solar The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. X The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. X The applicant's copy of the check list has been sent to: Carlson Solar PMB-221F 43430 E. Florida Avenue Hemet CA 92544 Esgil Corporation staff did not advise the applicant that the plan check has been completed. X Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Carlson Solar , «fe r^1^ Telephone #: 877 927-0782 Date contacted: ?l«loS (by: 5* f*** *****' Fax #: unk Mail /^Telephone -"" Fax y^ In Person REMARKS: By: Eric Jensen Enclosures: Esgil Corporation D GA D MB D EJ D PC 6/28 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 4- (858)560-1468 *• Fax (858) 560-1576 Carlsbad 04-2527 7/7/04 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: 04-2527 PROJECT ADDRESS: 2671 Cazadero Drive DATE PLAN RECEIVED BY DATE REVIEW COMPLETED: ESGIL CORPORATION: 6/28 7/7/O4 REVIEWED BY: Eric Jensen FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections on the originals and submit two new complete sets of prints to: ESGIL CORPORATION. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? Q Yes Q No Carlsbad 04-2527 7/7/04 ELECTRICAL CORRECTIONS PLAN REVIEWER: Eric Jensen 1. The licensed designer must sign the approved set of the plans. ELECTRICAL (1999 NATIONAL ELECTRICAL CODE) 1. Include the location of the subpanel. 2. Note on the single line diagram that the overcurrent devices in the subpanel and service equipment will be positively attached to the panelboard, the sole use of a stab-in connection will not be permitted. NEC 384-16(g) 3. Provide the module manufacturers DC maximum overcurrent protection device sizing, note on the plans, and demonstrate how this protection is provided on the single line diagram. Note: If you have any questions regarding this Electrical plan review list please contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad 04-2527 7/7/04 JURISDICTION: Carlsbad yALUATION AND PLAN CHECK FEE PLAN CHECK NO.: 04-2527 PREPARED BY: Eric Jensen DATE: 7/7/04 BUILDING ADDRESS: 2671 Cazadero Drive BUILDING OCCUPANCY:TYPE OF CONSTRUCTION: BUILDING PORTION Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA II Valuation (Sq. Ft.) Multiplier cb 1 QO4 I IRT Rt iltHInn Dorm it Paa V By Ordinance Reg. Mod. VALUE ($) 1994 UBC Plan Check Fee Type of Review: |~~] Repetitive FeeRepeats Complete Review D Other m Hourly $120.00 Structural Only Hour* Esgll Plan Review Fee $96.00 * Based on hourly rate Comments: Sheet of macvalue.doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB ADDRESS .AT. TIAL ADDITION MINOR « $10,000.00) TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER DATE ENGINEER ^C4^O^--r DATE oocs/Misrormsmanning Enginnrtng Approvals FROM :FAX NO. =9095878359 Jul. 12 2004 04:35PM P4 WARNING HAZARDOUS ELECTRIC!TV CRN SHOCK,BURN OR CAUSE DEATH. DO NOT TOUCH TERPIINflLS. PHOTOVOLTAIC MODULE MODEL SER NO. DATE IRRflDIANCE ftND CELL TEFIPERfiTURE Pvax Uprcax tpT«X Uoc Isc KC1B7G 0383AAA001 2003 . 8 1000Uw~2 fttt t.5 25 *C ^67U 23. 2 U 7.20ft 28. 9U 8. 00 A SOOUryT2 AM 1 .5 47 °C 120U 20. 4 U 5.90A rKK.SYS UOLT.i 6001.' SERIES FUSE 11 ft riflss 16.0kg CVSL7US LISTED FIELD WIRING 10 —' FIRE RATING CLASS C lllll!ii itir Hi Ill RETAINING UJALLS PER GRADING PLAN CONTRACTOR CARLSON SOLAR, INC PMB-221F, 43430 E. FLORIDA AVE. HEMET, CA 92544 PHONE: 877/927-0782 OWNER GREG ER1CKSON 2671 CAZADERO DR. CARLSBAD, CA 92009 PHONE: 949/322-0801 Grounding Is #10 (or larger) One Line Wiring Diagram for Photovoltaic System 2671 Cazadero Drive Carlsbad, CA 92009 36 Kyocera, 167 Watt Solar Modules 7/12/04 J Box located near solar modules Signage applied to visible disconnect Service Panel 200 Amp #10UVthrin/thwn (or larger)#12UVthhn/thwn (or larger) Sunny Boy 2500 Watt Inverter Visible Disconnect Signage applied to DC Disconnect WARNING Conductors Are Always Energized, Even When Main Is Disconnected There Are Up To 600 VDC The over-currant devices in the sub-panel and service equipment will be positively attached to the panelboard. per NEC 384-16<g) Grounding la #10 (or larger) from module racking to service panelground 3/4" (or larger) Conduit will be used from array to DC disconnect, and 1/2" EMT or NMFC from DC disconnect to service panel Signage applied to Sub and Service Panel WARNING Dual Power Supply Photovoltaic System Photovoltaic System For: Greg Erickson 2671 Cazadero Drive Carlsbad, CA 92009 (949) 322-0801 Submitted By: Carlson Solar Inc. 43430 E. Florida Ave PMB-221 Ste. F Hemet, CA 92544 (909) 927-0782 Signag* attached near main service showing inverter, array, and disconnect locations. SHARP February 4, 2004 Department of Building and Safety San Diego, CA RE: Mounting of Sharp Modules This letter is to confirm the use of Sharp modules with mounting structures manufactured by UnlRac, Direct Power & Water, and ProSolar. 1. The Solar Systems division of Sharp Electronics Corporation approves the use of all mounting systems and associated hardware manufactured by UniRac, Direct Power & Water, and ProSolar with its PV modules. 2. The mounting hardware components manufactured by the above companies are listed in the attached product sheets. Feel free to contact me should you have any questions regarding these matters. Thank you,, Arthur Rudin Director of Engineering SHARP Electronics Corporation Solar Systems Division 9501 Bolsa Avenue , Huntington Beach, CA 92647 RoofTrac RAILS RESIDENTIAL RAILS dear Amdrad Support rais 6 PACKS (ACCOMODATES 12 MODULES): RT-11M 110-Suppertttb $187.36 H-13W 13T$lH*tbfe $12118 H-13« ttrSuppmtbfc $13233 H-13M 13TSiwert Hafts $13138 SHIP METHODS:6 PACK SHIP WEIGHTS: R-11M 25 b. RT-13M 30 bs. R-1344 32 IB. RT-13M 35 b. COMMERCIAL/GROUND TRAC™ (DEEP CHANNa) RAILS Ctear AnwfizedZS" Deep Channel Support rafls BULK— BARE BUNDU (CRATED WITOOUT PACKAGING) MINIMUM ORDER OF 50 RAILS— PRICE IS PER RAIL": Qff-130 03-134 OK-136 136-StffiortW) $2162 $22.95 AVAILABLE IN BULK BARE BUNDLE ONLY SHIPMRHOOS: SHIPWDGHT5: 00-731 Off-134 TOb-eadi 00-138 SPLICE KIT Lower Supports—2 SHIPMtmOD: J^rSSLod Washers-^ PART NUMBERS: IT-SK4 SHIP WEIGHT: KT-9M .75 bs. IT-SK4-10 8 In $725 $7150 RAIL ACCESSORIES CHANNa COMPRESSION NUT RAIL ENHANCER Lower Support—20 Channel Compression But—20 3/8" Lock Hasher—20 PART NUMBERS: Strengftener 10 pairs $56100 SHIP METHOD:ws professionalSOLARproductSi DevetepereofttoOrigmalTcip-DomPVft^^ www.RoofTrac.com tipBdB[BtioiBJBb)trtt)clBHy*tftjMtPHk8 Pago 3 RoofTrac CLAMPING HARDWARE MODULE CLAMPS & HARDWARE KIT PACK PART NUMBERS (EACH BOX MOUNTS 12 MONIES IN AMY CONFIGURATION): RMOHS-S RT-SHU6-3 KT-miS-3 IT-OTC-3B n-EGMS-3 Kyocera fetor fete (tap (fear AwbnQ KymSotrlbMeClMp0hd(AMtize4 Mf Id* Wafers (301***»*»**»•»*•»•**»>»'•>>*»'*** Evergreen MMhteClMpi (d Each box ttatantare): $73J» [Kb bniibtk hardware}: $84.00 :+ Large "C" Channel design conceals hardware V connections, allows water to flow through to i prevent freezing in the channel Patented end clamp design provides inward tension against the module frame securing the lamiate under load Sliding aluminum channel nut provides a full 3" of grip support in the channel - will remain in place for ease of future service THE ProSolar PATENTED SLIDE-N-CLAMP SYSTEM: When deshping this Imorothe clamping system we took several factors into consideration: 1) Make a lightweight rail that conceals hardware and uses less malertalsoftw)uklbecosteffectivejfetaesthetically pleasing. 2) Make the componems of the damping system (^^ way that we can achieve high engineering values with less material. TWs is achtered because when the installed damps are tightened, the design of the damps pulls the tips of the C-channel together to create a theofetteal "square" enhancing the structural properties. Thfe "soft & tightveight" aluminum is new aMe to engineer to SOtbs per sq. ft (125mph wind toad) I 3) The labor to install on the rooftop-we would need a fast way tonKHimtnesafstemwhkAlshcw we designed the charoel m«. This mrt effortlessly slk*« galling ten't a proWem. 4) The rail wouW nave to be open, tetUrw water and debris clear the cnannel to pfcvem professionalSOLARproductsIOc,.v Owe**** of the Original Top-Oown PV Mounting System* ...— , ,—_——, ,——^~—£ y ? ijif ^j «**^_**— --•-*--• fc. * --*^ * «J— www.RoofTrac.rom Page4 FastJack ATTACHMENT The patented design of to Fast Jack® has a renwwMe stanchion that piw^ tween the CMC naehined base and stanchwnatan^ tested to prwi(te 1,200 poimds of strength using o^ Paper can roll over base (no heavy lifting over a stanchion) Base fits perfectly under the flashing base. Stainless steel hardware will not cause rusting FASTJACK® Pat, #6^60,491 1" Di 5/16"x3*SSLag loft (1$ W16-SS faster (H) 3/TSSHexBolt(l8) 3/8"$$ Waster (IS) PART NUMBERS: FJ-300-18 r Fast Jacks FW50-18 4-1/T Fast Jacks FI400-18 rfastJacks FJ-750-18 7-1/TFastJacks SHIPMCTHOO: $12181 $128.54 $140.* $151.71 -in large quantHies Integrated precision drill guide for accurate drilling into the rafter SHIP WEIGHT: FJ-300-18 9Ibs, FJ-450-18 11 bs. FWOO-18 13fcs, FJ-750-18 14 IDs, Suggested Accessoryi .+jjH. jr.. ; FJ450 sizes) Removable post makes retrofit installations on existing roofs fast & easy. professionalSOLAR products t ng System www.RoofTrac.com TriTek Engineering, Inc. CIVIL ft STRUCTURAL ENGINEERING DESIGN 71221/2 Topanga Canyon Blvd., Suite A, Canoga Park, California 91303 Professional Sokr Products 4630 Cale Quetzal Caroaritto.CA 83012 Attn: Stan Ulman Date of observation test: April 24.2002 MEMO: Engineering appBes to modules manufactured by Sharp Corporation and the proprietary mounting system manufactured by Professional Solar Products, Camarilto, CA. Mounts wlB be dearly identified Tie Trac" with a permanent adhesion label. Subject: Sharp Solar Tile Trac test TEST SETUP FLAT MOUNT; Four Sharp Safer 32.^ x 62" torifl modules bolted to 1.5" x 15" x 136' supports using a combination of 10ee. 5/16" atonies* steel bolts, took washers and spedaty extruded Inserts. The mounting channel was attached to the module mourtlng wHh a 3/8* nui and washer at six attachment points to a TBe Trac mount The Spans tested consisted of a front to rear of 48*. The entire set up was supported by to four by alx beams resting on ttw concrete floor. The Tile Trac mount will support NE-Q5E2U, NE-K126U2. NE-BOE'U. ND-QQE2U, ND-L3E1U(photovottaic modules. Teat Procedure: The test set up was loaded using sandbags that produced an eciurvaJert 50*%q.ft. toaoTrtfl. Upon completion of the placement of tie sandbags the maximum deflecBun that occurred was W. The sandbags were teft for 30 minutes with no change in the defection or any other sign of distress. After the 30 minutes was completed the fixture was Inverted to simulate the download condition. The results of the tests were duplicated In the uptlt oonoHon The detection was K'iraximum and the fixture suffered no signs of distress due to the loading. This document eerttfiet the Tie Trac mount and accompanying Hit up support, used wtth Sharp Solar modules, wthstands a 50 b. per square foot static pressure load, this loading Is equivalent to a wind apeed of approximately 125 man as defined tr the 1967 Uniform Buldlng Code. Overs! fre mourrlng unit performed as expected. Sincerely AfiBasma RGE j Control No. 3HRP-TT-FL.P [ Page 1 Note: This engineering la not Intended for use In obtaining a permit for systems other than the above mentioned configuration. Unless otherwise directed r writing, this engineering shall not be puMcly posted or copied. v" 32 M t— • — t Ix XTip i tef IX XL 1 >N3\J f*\ o> 1 r 8 rjH r ha 4&00 SK POLICYHOLDER COPY P.O. six? 867) SAN FRANCISCaCA 94142-^807COMPENSATION •>• •-.., ... >" ? :; :; ' ' , , '" . < . ' • ... ..•--"• ; ' ,, •--•-.. "\ ':/ /' • • CERTIFICATE OF WORKERS' COMPENSATION INSURANCE ISSUE DATE 01-01-2004 * GROUP: 000229 POLICY NUMBER: 0021058-2004 . ; . CERTIFICATE l& 9 \ < , CERTJF1CATE SPIRES: O1-O1-20O8; -. :• O1-01-20O4/01-01-20O5 CONTRACTORS STATE LICENSE BOARD SK ' LICENSE NUMBER: LICENSE #812958P.6. BOX 2€bOO; ............. INCEPTION DATE: 01-01-2004 , SACRAMENTO " : -- "- :- / D.O.: SK CA. 95826 • This is to certify that we twa issuvd a valid Workers' Compensation insurance policy in • form approved by the California Insurance Commissioner to the employer named below for the policy period indicated. This policy is not subject to cancellation by the Fund except upon 30 days' advance written notice to the employer. We will also give you go d*W advance notice should this policy be cancelled prior to its normal expiration. This certificate of Insurance is not an Insurance policy and does not amend* extencf or alter the coverage afforded by the policies listed herein, Notwitnstandtnfl any requirernent, term, or condition of any contract or other document with respect- to which this certificate of iniuranc* may be issued or may pertain, the insurance afforded by the policies described herein is subject to all the terms, exclusions and conditions of such policies. ' AUTHORIZED .RlEPRESEfrfTATIVE PRESIDENT,; EMPLOYER'S LIABILITY LIMIT INCLUDING DEFENSE COSTS; $1,OOO,OOO.OO PER OCCURRENCE. ENDORSEMENT #206B ENTITLED CERTIFICATE HOLDERS' NOTICE EFFECTIVE O1-O1-20O4 IS ATTACHED TO AND FORMS A PART OF THIS POLICY. :• \ '"-."? , / EMPLOYER LEGAL NAME CARLSOH-SOLAR ELlCTRICAL; SYSTEMS -,/ CARLSON SOliAR MH2 HEftCEO R& I ^ -'""""\ H6HET CA 9251*1* I :