HomeMy WebLinkAbout2669 GATEWAY RD; 103; CB111046; Permit08-04-2011
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No: CB111046
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
Project Title:
2669 GATEWAY RD CBAD St: 103
Tl Sub Type:
2131912600 Lot#:
$47,031.00 Construction Type:
Reference #:
SUPERCUTS-1267 SF SHELL TO
HAIRSALON
COMM
0
NEW
Applicant:
LNR CPI BRESSI RETAIL L L C
C/0 LNR PROPERTY CORP
4350 VON KARMAN AVE #200
NEWPORT BEACH CA 92660
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
Plan Check*:
Owner:
LNR CPI BRESSI RETAIL L L C
C/0 LNR PROPERTY CORP
4350 VON KARMAN AVE #200
NEWPORT BEACH CA 92660
ISSUED
05/17/2011
KG
06/28/2011
06/28/2011
TP
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'l Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB1473) Fee
Fire Expedited Plan Review
$405.42 Meter Size
$0.00 Add'l Reel. Water Con. Fee
$263.52 Meter Fee
$0.00 SDCWA Fee
$0.00 CFD Payoff Fee
$9,88 PFF (3105540)
$0.00 PFF (4305540)
$0.00 License Tax (3104193)
$0.00 License Tax (4304193)
$0.00 Traffic Impact Fee (3105541)
$0.00 Traffic Impact Fee (4305541)
$0,00 PLUMBING TOTAL
$0.00 ELECTRICAL TOTAL
$0.00 MECHANICAL TOTAL
$0.00 Master Drainage Fee
Sewer Fee
$0.00 Redev Parking Fee
$0.00 Additional Fees
$1.00 HMPFee
$250.00
TOTAL PERMIT FEES
$0.00
$0.00
$0.00
$0.00
$855.96
$0.00
$0.00
$0.00
$0.00
$0.00
$83.00
$60.00
$33.00
$0.00
$0.00
$0.00
$0.00
$1,961.78
Total Fees:$1,961.78 Total Payments To Date:$1,961.78 Balance Due:$0.00
Inspector:
FINAL APPROVAL
Date:Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions, If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32,030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which vou have oreviouslv been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired.
CITY OF
CARLSBAD
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
760-602-2717/2718/2719
Fax 760-602-8558
www.carlsbadca.gov
Plan Check
Est. Value
Plan Ck. Deposit
SWPPP
JOB ADDRESS 2669 Gateway Road SUITE#/SPACE#/UNIT#
103
CT/PROJECT*LOT##BEDROOMS # BATHROOMS
1
TENANT BUSINESS NAME
SUPERCUTS
CONSTR. TYPE
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s)
Tenant Improvements for av1300-*q ft inline space. Walls to divide space for Office & Service Areas, Wallcovering, Vinyl
flooring, Cabinets, Fixtures, Lighting, Plumbing & Electrical for a Supercuts Hair Salon.
EXISTING USE
New Building
PROPOSED USE
Hair Salon
GARAGE (SF)
N/A
PATIOS (SF)
N/A
DECKS (SF)
N/A
FIREPLACE
YES|~>.NOl/l
AIR CONDITION ING
YES [71 NO | |
FIRE SPRINKLERS
NOl |
CONTACT NAME (If Different Font Applicant)APPLICANT NAME Robert Jerome
ADDRESS ADDRESS
7750 El Camino Real, Suite 2G
CITY STATE ZIP CITY
Carlsbad
STATE
CA
ZIP
92009
PHONE FAX PHONE
760-753-5543
FAX
760-753-7520
EMAIL EMAIL sstbob@msn.com
PROPERTY OWNER NAME LNR Property Corporation CONTRACTOR BUS. NAME
ADDRESS
4350 Von Karman Avenue #200
ADDRESS
CITY
Newport Beach
STATE
CA
ZIP
92660
CITY STATE ZIP
PHONE
949 885-8500
FAX
949 885-8501
PHONE FAX
EMAIL
sarms@lnrproperty.com
EMAIL .Otf
ARCH/DESIGNER NAME & ADDRESS
Kendall Youna, 720 York #104. SF 944 C7565
civil penalty of not more than five hundred dollars {$500}).
WO R K E R S C O M P E N S A T I O N
Jstructure, prior to its isslarfce, also requires the, commending with Section 7000 of Division 3 of the,5 by any applicant for a permit subjects the applicant to a
Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations:
L/J I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
I 11 have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co Policy No. Expiration Date
Thjfsection need not be completed if the permit is for one hundred dollars ($100) or less.
JyiCertificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damageV8t,pxftyided.»r u/Section^BOS of the Labor code, interest and attorney's fees.
£$ CONTRACTOR SIGNATURF-^O^/ A dAGENT DATE (& " 2$ " 2-&I (
O W N E R - B U I L O E R O EC L A I! A T I O N
/ hereby affirm that I am exempt from Contractor's License Law for the following reason:
| | I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
| | I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
I am exempt under Section _.Business and Professions Code for this reason:
1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. I JYes I JNo
2.1 (have / have not) signed an application for a building permit for the proposed work.
3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number):
4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number):
5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work):
^PROPERTY OWNER SIGNATURE AGENT DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? | | Yes I / JNo
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or airouality management district? I lYes F71 No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? I JYes 1/lNo
IF ANY OF THE ANSWERS ARE YES, t
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
CONST R U CTION LENDING AG EN C Y
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name HI A. Lender's Address
A P P L I C A N T C E R T I F I C A T I O N
I certify that I have read the application and state that the above information Is correct and that the information on the plans is accurate .I agree to comply witti all City oidinances and State laws relatingtD building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes, i ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within
180 days from the date of such permit or if the buMng~oni
^APPLICANT'S SIGNATURE
authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 1 80 days (Section 1 06.4.4 Uniform Building Code).
DATE
City of Carlsbad Bldg Inspection Request
For: 08/02/2011
Permit* CB111046
Title: SUPERCUTS-1267 SF SHELL TO
Description. HAIR SALON
Inspector Assignment: TP
2669 GATEWAY RD
103 Lot: 0
Type:TI Sub Type: COMM
Job Address:
Suite:
Location:
OWNER LNR CPI BRESSI RETAIL L L C
Owner:
Remarks: AFTER 9:30AM
Total Time:
Phone: 7602778,752
Inspector:
Requested By: JEFF
Entered By: CHRISTINE
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Act Comments
Comments/Notices/Holds
Associated PCRs/CVs/SWPPPs Original PC#
Date
07/29/201 1
07/29/201 1
07/29/201 1
07/29/2011
07/29/201 1
07/28/201 1
07/28/201 1
07/28/2011
07/28/201 1
07/15/2011
07/13/2011
07/13/2011
07/13/2011
Inspection History
Description
14
23
34
44
44
14
23
34
44
17
14
24
34
Frame/Steel/Bolting/Welding
Gas/Test/Repairs
Rough Electric
Rough/Ducts/Dampers
Rough/Ducts/Dampers
Frame/Steel/Bolting/Welding
Gas/Test/Repairs
Rough Electric
Rough/Ducts/Dampers
Interior Lath/Drywall
Frame/Steel/Bolting/Welding
Rough/Topout
Rough Electric
Act
AP
we
AP
we
AP
CO
AP
CO
PA
AP
AP
AP
AP
Insp
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
Comments
T-CLNG EXISTNG
NEW CLNG LITES
NEW/RE-LOC MECH DUCTS, REG.
TCEIL
WALLS
City of Carlsbad Bldg Inspection Request
For: 08/02/2011
Permit* CB111046
07/13/2011 44 Rough/Ducts/Dampers WC TP
07/11/2011 14 Frame/Steel/Bolting/Welding PA TP
07/11/2011 24 Rough/Topout PA TP
07/11/2011 34 Rough Electric PA TP
07/06/2011 11 Ftg/Foundation/Piers AP TP
07/05/2011 21 Underground/Under Floor AP TP
07/05/2011 22 Sewer/Water Service AP TP
Inspector Assignment: TP
TO ONE SIDE ONLY
TO VENT
SLAB PREP FOR PLUMB TRENCHES
City of Carlsbad
Final Building Inspection
Dept: Building Engineering Planning CMWD St Lite Fire
Plan Check #:
Permit*:
Project Name:
Address:
Contact Person:
Sewer Dist:
Inspected
Bv: /
Inspected
Bv:
Inspected
Bv:
Comments:
CB111046
SUPERCUTS-1267 SF SHELL TO
HAIR SALON
2669 GATEWAY RD #103
JEFF Phone: 7602778752
CA Water Dist: CA
^x<7 Date /yl 1
<2( YwA/l^~^ Inspected: o(2'K£^ I if f
' Date
Inspected:
Date
Inspected:
Date:
Permit Type:
Sub Type:
Lot: 0
)|( Approved: (^
Approved:
Approved:
08/02/2011
Tl
COMM
Disapproved:
Disapproved:
Disapproved:
EsGil Corporation
In (Partners Kip with government for Quitting Safety
DATE: 6/23/11 a AEBUC.ANT
JURIJ
JURISDICTION: City of Carlsbad OTtAN REVIEWER
a FILE
PLAN CHECK NO.: 11-1046 SET: II
PROJECT ADDRESS: 2669 Gateway Rd Suite 103
PROJECT NAME: Supercuts - TI
XI The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
J The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
A] Esgil Corporation staff did not advise the applicant that the plan check has been completed.
I I Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Email: Fax #:
Mail Telephone Fax In Person
1 REMARKS:
By: Doug Moody Enclosures:
EsGil Corporation
D GA D EJ D PC 6/16/11
9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576
I' ..... g.~ ..' i • SSS
EsGil Corporation
In Partnership -with government for <BuiCding Safety
DATE: 5/26/11 0 lAPJElJCANT
JURISDICTION: City of Carlsbad O>CMREVIEWER
Q FILE
PLAN CHECK NO.: 11-1046 SET: I
PROJECT ADDRESS: 2669 Gateway Rd Suite 103
PROJECT NAME: Supercuts - TI
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
XI The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
X] The applicant's copy of the check list has been sent to:
Robert Jerome
7750 El Camino Real Suite 2G, Carlsbad, CA 92009
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
X] Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Robert Jerome Telephone #: 760-753-5543
Date contacted: slt^m (by; \t+,) Email: sstbob@msn.com Fax #: 760-753-7520
£wiailb< Telephone Fax-X In Person
REMARKS:
By: Doug Moody Enclosures:
EsGil Corporation
D'GA D EJ D PC 5/19/11
9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576
City of Carlsbad
5/26/11
11-1046
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 11-1046
OCCUPANCY: B
TYPE OF CONSTRUCTION: VB
ALLOWABLE FLOOR AREA:
SPRINKLERS?: Yes
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 5/17/11
DATE INITIAL PLAN REVIEW
COMPLETED: 5/26/11
JURISDICTION: City of Carlsbad
USE: Hair Salon
ACTUAL AREA: 1267sf
STORIES: 1
HEIGHT:
OCCUPANT LOAD: 38
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 5/19/11
PLAN REVIEWER: Doug Moody
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and access for the disabled. This plan
review is based on regulations enforced by the Building Department. You may have other
corrections based on laws and ordinances enforced by the Planning Department, Engineering
Department, Fire Department or other departments. Clearance from those departments may be
required prior to the issuance of a building permit.
Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2009 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e.. plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
City of Carlsbad 11-1046
5/26/11
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
1. Please provide a statement on the Title Sheet of the plans to show compliance
with the current Codes. The following are the correct current Codes:
a) The 2010 edition of the California Building Code (CBC) adopts the 2009
International Building Code (IBC) and the 2010 California Amendments.
b) The 2010 edition of the California Electrical Code (CEC) adopts the 2005
National Electrical Code (NEC) and the 2008 California Amendments.
c) The 2010 edition of the California Mechanical Code (CMC) adopts the
2006 Uniform Mechanical Code (UMC) and the 2009 California
Amendments.
d) The 2010 edition of the California Plumbing Code (CPC) adopts the 2006
Uniform Plumbing Code (UPC) and the 2009 California Amendments.
e) The 2010 edition of the California Fire Code (CFC) adopts the 2009
Uniform Fire Code (UFC) and the 2007 California Amendments.
f) The 2008 edition of the California Energy Efficiency Standards.
2. Provide a section view of all new interior partitions. Show:
a) Method of attaching top and bottom plates to structure. (NOTE: Top of
partition must be secured to roof or floor framing, unless suspended
ceiling has been designed for partition lateral load).
b) Show height of partition and suspended ceiling, and height from floor to
roof framing or floor framing.
3. Please note in the general wiring notes on the plans "AC Cable is not allowed in
A, B, E, H, F, M, S and I occupancies. NM cable is restricted (without City
approval) to one and two family dwellings. Note on plans that an equipment
ground conductor is to be installed in all flexible conduits".
City of Carlsbad 11-1046
5/26/11
4. Please have the principle designer of the LTG-1-C form sign the imprinted
document.
5. Please clarify the LTG-1-C part 3 of 4 mandatory automatic controls portion of
the LTG-1-C form to indicate what the by-pass timer is and how it complies as
the required complete building shut-off?
6. Please correct the Statement of Compliance System Acceptance section of the
LTG-1-C part 4 of 4 documents to be consistent with the 3 of 4 form and show
the correct complete building shut-off.
7. Please clarify the LTG-4C form I was unable to find 666 square feet of display
floor area or 28' of wall display? How were these area determined?
8. Plumbing plan Provide complete plumbing plans, including:
c) Provide gas line plans and calculations, showing pipe lengths and gas
demands. UPC Section 1217.0
d) Show water heater size, type and location on plans. UPC, Section 501.0
9. Provide the following information concerning the water heater:
• Show water heater size, type and location on plans, UPC 501.0
• Provide combustion air design: Show opening sizes and routing of ducts.
UPC 507.0
• Detail the water heater vent installation: Size, routing, slope, and termination
location (Minimum 8'from vertical surfaces). UPC 510.0
• Gravity vent water heaters may not be installed in the same area with air
moving equipment (clothes dryers). Please address.
• An expansion tank or other approved device is required if system pressure
relief is not available due to the installation of backflow devices or certain
pressure regulators. Please address. UPC 608.3
10. Please revise the plumbing plans to show the required clean-outs per section
707 and 719 of the UPC.
Note : When alterations, structural repairs or modifications or additions are made to an
existing building, that building, or portion of the building affected, is required to comply
with all of the requirements for new buildings, per Section 1134B.2. These requirements
apply as follows:
a) The area of specific alteration, repair or addition must comply as "new"
construction.
b) A primary entrance to the building and the primary path of travel to the
altered area, must be shown to comply with all accessibility features.
11. Show that accessible parking spaces comply with Section 1129B.3.1 as follows:
City of Carlsbad 11-1046
5/26/11
a) Single spaces shall be 14' wide and outlined to provide a 9' parking area
and a 5' loading and unloading area on the passenger side of the vehicle.
12. Please revise the plans to show a disabled accessible transaction counter located
at a section of the main counter that is at least 36" long and no more than 28" to
34" high (flip-up or folding or pull out counters are only permitted in existing
buildings when a finding of unreasonable hardship is found by the building
Official). Section 1122B.5.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes Q No a
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Doug Moody at
Esgil Corporation. Thank you.
City of Carlsbad 11-1046
5/26/11
[DO NOT PAY-THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad PLAN CHECK NO.: 11-1O46
PREPARED BY: Doug Moody DATE: 5/26/11
BUILDING ADDRESS: 2669 Gateway Rd Suite 103
BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VB
BUILDING
PORTION
Tl
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
( Sq. Ft.)
1267
cb
Valuation
Multiplier
34.37
By Ordinance
Reg.
Mod.
VALUE ($)
43,547
43,547
Bldg. Permit Fee by Ordinance
Plan Check Fee by Ordinance
Type of Review:
I I Repetitive FeeRepeats
Complete Review
D Other
r—I Hourly
EsGil Fee
I l Structural Only
Hr. @
$379.14
$246.44
$212.32
Comments:
Sheet 1 of 1
macvalue.doc +
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER (Vfe 1 1
ADDRESS •
DATE
RESIDENTIAL
RESIDENTIAL ADDITION MINOR
(<$20,000.00)
TENANT IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER ?g^£(3?(07-Z'?i<r/ NO
PLANNER
ENGINE
DATE
DATE I
Q:\CED\LandDav\Correspondence\Ontiveras\for planchecking\BUILDINQ PLANCHECK CKLIST FORM - PLANNING ENGINERING APPROVALS docx
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB111046 DATE 5/18/11
ADDRESS 2669 GATEWAY RD #103
RESIDENTIAL ADDITION-
MINOR (< 17,000.00)
RETAINING WALL
VILLAGE FAIRE
POOL/SPA
TENANT IMPROVEMENT
COMPLETE OFFICE BUILDING
SOLAR PANELS
OTHER
PLANNER GINA RUIZ
ENGINEER
DATE 5/18/11
DATE
H:\ADMIN\COmTER/PUNNlNG/ENGINEERING APPROVALS
RECOMMENDED FOR APPROVAL Page: 1 of 2
Daryl K. James & Associates, Inc. Checked by: Susan Guzzetta
Date: June 19. 2011
APPLICANT: Robert Jerome JURISDICTION: Carlsbad Fire Department
PROJECT NAME: Supercuts PROJECT ADDRESS: 2669 Gateway Road
Carlsbad
PROJECT DESCRIPTION: CB111046 T.I. for a 1300 sq. ft. space.
INSTRUCTIONS
• This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted
by the Carlsbad Fire Department.
• The items below require correction, clarification or additional information before this plan check can be approved
for permit issuance.
• To expedite the recheck process, please note on this document (or copy) how and where each correction item
listed below has been addressed (sheet number, note number, detail number, legend number, etc.). Corrections
or modifications to the plans must be clouded and provided with numbered deltas and revision dates.
• PLEASE SEND OR DELIVER REVISED PLANS WITH BUILDING DEPT. COMMENTS DIRECTLY TO:
SUSAN GUZZETTA
5121 COSTA RUSTICO
SAN CLEMENTE, CA 92673
• Please direct any questions regarding this review directly to: Susan Guzzetta at 949-573-1558 or
stguzzetta@qmail.com
A1.0
V The applicable codes must be listed on the cover sheet. Please list the current applicable codes for this project:
Fire Code added to General Terms and Conditions list on sheet AO.O
The current edition (2010 Codes) of CCR Title 24 includes:
• Part 1, named the California Building Standards Administrative Code;
• Part 2, Volume 1 and 2, named the 2010 California Building Code and is based on
the 2009 International Building Code;
• Part 2.5, named the 2010 California Residential Code and is based on the 2009
International Residential Code;
• Part 3, named the 2010 California Electrical Code and is based on the 2008 National
Electrical Code;
• Part 4, named the 2010 California Mechanical Code and is based on the 2009
Uniform Mechanical Code;
• Part 5, named the 2010 California Plumbing Code and is based on the 2009 Uniform
Plumbing Code;
• Part 6, named the 2010 California Energy Code;
• Part 8, named the 2010 State Historical Building Code;
• Part 9, named the 2010 California Fire Code and is based on the 2009 International
Fire Code;
• Part 10, named the 2010 California Existing Building Code and is based the 2009
International Existing Building Code;
• Part 11, named the 2010 California Green Building Standards Code, and is also
called the CALGreen Code;
• Part 12, named the 2010 California Reference Standards Code.
V Provide note on plans that any sprinkler modifications will be a deferred submittal.
Note #4 on sheet A1.0 has been revised.
Page 2 of 2
V Indicate location of Fire Extinguisher.
Fire extinguisher shown on sheet A1.0 at trash alcove at rear door.
V Provide note on plans that walls and ceiling finishes will meet requirements from California Building Code
Section 803.
Note added on sheet AO.O
Carlsbad Fire Department <""/"% ST^if«L.->Ur ,
Plan Review Requirements Category: TI , COMM
Date of Report: 06-24-201 1 Reviewed by:
Name:
Address:
LNR CPI BRESSI RETAIL L L C
C/O LNR PROPERTY CORP
4350 VON KARMAN AVE #200
NEWPORT BEACH CA
92660
Permit #: CB1 11046
Job Name: SUPERCUTS-1267 SF SHELL TO
Job Address: 2669 GATEWAY RD CBAD St: 103
yM^a^^VYYViY YW*VYVVVYYYYYW vvwwviv w.yy w vv vwwvw VYYYYYYVYYYYYYYYYVYY YYY Y vvYVWY^YYVY-vvYY v^v
w
Conditions:
Cond: CON0004716
[MET]
** CITY OF CARLSBAD FIRE DEPARTMENT - APPROVED:
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF
BUILDING PERMIT.
THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON,
CONDITIONS IN
CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS.
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW.
Entry: 06/24/2011 By: GR Action: AP
SAN DIEGO REGIONAL
HAZARDOUS MATERIALS QUESTIONNAIRE
OFFICE USE ONLY
UPFP#
HV#
BP DATE /
Business Name Business Contact Telephone #
Project Address
r=f_
State ZipCocte APN#
Mailing Address Ci State Zip Code Plan Fite#
Project Contact J-Telephone #r
The following questions represent the facility's activities, NOT the specific project description.
PART I: FIRE ggPJRTMENT - HAZARDOUS MATERIALS DIVISION; OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business
will use, process, or store any of the following hazardous materials. If any "bfthe items are circled, applicant must contact the Fire Protection Agency with
jurisdiction prior to plan submittal. Facility's Square Footage (including proposed project): Occupancy Rating:
1 Explosive or Blasting Agents 5 Organic Peroxides 9. Water Reactives 13. Corrosives
2. Compressed Gases 6. Oxidizers 10. Cryogenics 14 Other Health Hazards
3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These.
4. Flammable Solids 8. Unstable Reactives 12. Radloactives
PART II; jJAft plE<?0 COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD}: 11
questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Ave., Suite 110, San Dieg
Call (858) 505-6700 prior to the issuance of a building permit
FEES ARE REQUIRED. Project Completion Date: $ I f / EOti Expected Date of Occupancy: § /$ /7ft jf/
YES NO, (for new construction or remodeling projects)
1. D El Is your business listed on the reverse side of this form' (check all that apply).
2. D 0 Will your business dispose of Hazardous Substances or Medical Waste in any amount?
3. D 0 Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds
/ 200 cubic feet, or carcinogens/reproductive toxins in any quantity?
4, D £0 Will your business use an existing or install an underground storage tank?
5. D OS/Will your business store or handle Regulated Substances (CalARP)?
6. D CL/ Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10}?
7. O 0 Will your business store petroleum in tanks or containers at your facility with a total storage capacity equal to
or greater than 1,320 gaBons? (California's Aboveground Petroleum Storage Act).
!he answer to any of the
o, CA92123.
D CalARP Exempt
Date Initials
D CalARP Required
Date Initials
HI CalARP Complete
Date Initials
PART III: SAJjDlfifjO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air
Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 588-2600 prior to the issuance of a building or demolition
permit Note: if the answer to questions 4 or 5 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to
commencing demolition or renovation, except «tasfi|ljga,at!a£iaxilli0 of residential structures of four units or !ess. Contact the APCD for more information.
YES
D
NO.
3.
4.
5.
EC Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the
APCD factsheet at htto.ffwmw sdapod.OfQtoMa«t/pa_cTOrt_%_gdf. and the list of typical equipment requinng an APCD permit on the reverse side
of this from. Contact APCD if you have any questions).
D D (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)?
(Search the California School Directory at http:tfwww cda ca aov/re/sd/ for public and private schools or contact the appropriate school district).
D EL Has a survey been performed to determine the presence of Asbestos Containing Matenals?
D lL> Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos?
CD 0 Will th0re be demolition involving the removal of a load supporting structural member?
Briefly describe business activities:Briefly describe proposed project:
I declare under penalty ofperjury that to the best of my knowledge and belief the^respop nadfi herein are true and correct.£ I 21 I
Name of Owner or Authorized Agent Signature of Owner orwuthonzed Agent Date
FIRE DEPARTMENT OCCUPANCY CLASSIFICATIONL
BY:
FOR OFFICIAL USE ONLY:
DATE'
EXEMPT OR NO FURTHER INFORMATION REQUIRED
COUNTY-HMD*APCD
RELEASED FOR BUILDING PERMIT BUT MOT FOR OCCUPANCY
COUNTY-HMO APCD
RELEASED FOR OCCUPANCY
COUNTY-HMD APCD
HM-9171 (02/11) County of San Diego - DEH - Hazardous Materials Division