HomeMy WebLinkAbout2689 OCEAN ST; ; CB142399; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 12-10-2014 Residential Permit Permit No: 0B142399 Building Inspection Request Line (760) 602-2725 Job Address: 2689 OCEAN ST CBAD Permit Type: RESDNTL Sub Type: RAD Status: ISSUED Parcel No: 2031403500 Lot #: 0 Applied: 09/18/2014 Valuation: $35,000.00 Constuction Type: 5B Entered By: RMA Occupancy Group: Reference #: Plan Approved: 12/10/2014 # Dwelling Units: 0 Structure Type: Issued: 12/10/2014 Bedrooms: 0 Bathrooms: 0 Inspect Area: Orig PC #: Plan Check #: Project Title: KUNKEL RES- REMODEL APPROX 400 SF EXISTING BATHROOMS/ KITCHEN / REPLACE ALL WINDOWS/ RESTUCCO WHOLE HOUSE Applicant: Owner: PRIVATE EYES ENGINEERS KUNKEL J RICHARD STE B-i 2420 GRAND AV . 508 W LOOKOUT DR #14-1043 VISTA CA 92081 RICHARDSON TX 75080 760 599-8566 . . Building Permit $310.09 Meter Size AddI Building Permit Fee $0.00 Add'l Red. Water Con. Fee $0.00 Plan Check $217.06 Meter Fee $0.00 AddI Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount S $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $4.55 PFF (3105540) $0.00 Park in Lieu Fee $0.00 PFF (4305540) $0.00 Park Fee • . $0.00 License Tax (3104193) $0.00 LFM Fee $0.00 License Tax (4304193) $0.00 Bridge Fee . $0.00 Traffic Impact Fee (3105541) $0.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541) $0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee . $0.00 PLUMBING TOTAL • $89.00 Renewal Fee $0.00 ELECTRICAL TOTAL $45.00 Add'l Renewal Fee $0.00 MECHANICAL TOTAL $39.80 Other Building Fee $0.00 Housing Impact Fee $0.00 HMP Fee $0.00 Housing lnLieu Fee $0.00. Pot. Water Con. Fee $0.00 Housing Credit Fee $0.00 Meter Size Master Drainage Fee $0.00 Add'I Pot. Water Con. Fee $0.00 Sewer Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 Green Bldg Stands (SB1473) Fee $1.00 Fire Sprinkler Fees $0.00 Green Bldg Stands Plan Chk Fee $0.00 TOTAL PERMIT FEES . $706.50 Total Fees: $706.50 Total Payments to Date: $706.50 Balance Due: $0.00 FINAL APP Insnctnr, ______________ Date: c. Clearance: NOTICE: Please take NOTICE that approval of your project includes the'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions. You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030: Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any I THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: D PLANNING D ENGINEERING 0 BUILDING 0 FIRE 0 HEALTH HAZMATIAPCD Building Permit Application 401h> 1635 Faraday Ave., Carlsbad, CA 92008 CITY O F Ph: 760-602-2719 Fax: 760-602-8558 CARLSBAD email: building@carlsbadca.gov www.carlsbadca.gov UNITA_ Plan Check No. Est. Value 35 pp.- Plan Ck. DeposIt /7. Date t! 11u11c( Iswppp I JOB ADDRESS 2 z?? 2 () 15 ,66,-9 SUITEI/SPACES/ 1A - - - T/PROJECT# 1 L01# PHASE # I # OFi UNITS # BEDROOMS .)ESCRIPTION OF WORK: Include Square Feet of Affected Area(s).4)J)Th.9C.LL) _9PtOL..€ # BATHROOMS TENANT BUSINESS NAME I CONSTR. TYPE Iv-w 0CC. GROUP . 7 i, EXISTING USE • PC e5,_4,j_ I PROPOSED USE k1I_3 I GARAGE (SF) 7 ' PATIOS (SF) I DECKS (SF) Ia I_'P NODI_YES I FIREPLACE lAIR CONDITIONING NOD I FIRE SPRINKLERS I_YESDNO APPLICANT NAME , 'V Vii ,4 cyej c, ',' ec PROPERTY OWNER NAME , _£vy Kti71< ADDRESS q ,',j / ADDRESS 15 17 e!574 STATE ZIP CITY V' CITY ______STAT ZIP _ PHONE _FAX7 5y/ PHONE 7 -~7 EMAIL m peEi1i'rieeri EMAIL KL,1,K/e4/xe e r"" DESIGN PROFESSIONAL 4'4'e oao _ CONTRACTOR BUS. NAME _ , ADDRESS rri _(flALy!I4-fD ADDRESS CITY / CITY STATE ZIP PHONE FAX PHONE EMAIL EMAIL STATE LIC. # STATE LIC.# CLASS CRY BUS. UC.# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law IChapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil oenaltv of not more than five hundred dollars ($50011). ®(1&(P (®?O®() Workers' Compensation Declaration: I hereby at urn under penalty of perjury one of the following declarations: RI have and will maintain a certificate of consent to self.Insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers compensation insurance carrier and policy number are: Insurance Co. Policy No. Expiration Date T section need not be completed if the permit is for one hundred dollars ($100) or less. Certificate of Exemption: I ceiMy that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), In addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code, Interest and attorney's fees. Al CONTRACTOR SIGNATURE 0 AGENT DATE ®o00010 ®&i000 I hereby aflirrn that lam exempt from Contractor's License Law for the following reason: [J I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or cifered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). [J I am exempt under Section ____________Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement []Yes EI'io 2.1 (have! have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address! phone! contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name! address! phone /contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) th owing persons to provide the work indicated (include name! address! phone Itype of work): .'PROPERTY OWNER SIGNATURE \f"Y'\ 4 X—GENT DATE 01 Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 Yes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?, 0 Yes 0 No. Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 Yes 0 No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. L2? I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name N 'A-' Lender's Address . IcertifythatIhavereadtheappIIcationandstatethattheaboveinfonnationIscorrectandthattheinlOnnationontheptansisaocumte. I agree tocomptywithall C11yordinancesandStatelaws relating tobui!dingcenstnicdon. Ihereby authorize representative ofthe City of Carlsbad to enter upon the above mentioned properly for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CFIYOF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY INCONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA:- An OSHA permit is required for excavations over 5'O' deep and dernollion or construction of structures over 3stories in height. EXPIRATION: Every permit issued by the Building Offcial under the provisions of this Code shall expire by Imftatian and become null and vold if the building or work authorized by such permit isnot commenced within 180 days from the date of such permit or if the building or work authorized 7u, permitissuspended or abandoned at any time after the workis commenced fora period of 180 days (Section 106A.4UniformBuilding Code). .APPLICANT'SSIGNATURE "' ' DATE 0 / - Inspection List Permit#: CB142399 Type: RESDNTL RAD KUNKEL RES- REMODEL APPROX 400 SF EXISTING BATHROOMS! KITCHEN Date, Inspection Item Inspector Act Comments 02/18/2016 89 Final Combo PD AP 08/31/2015 82 Drywall/Ext Lath/Gas Test PY AP 08/19/2015 84 Rough Combo PY AP 08/04/2015 21 Underground/Under Floor PY AP 08/04/2015 24 Rough/Topout PY PA 08/04/2015 33 Service Change/Upgrade PY AP Friday, February 19, 2016 Page 1 of 1 EsGil Corporation In Partnersfiip wit/i government for (Building Safety DATE: 11/25/14 13-APPLICANT JURI JURISDICTION: Carlsbad UP[ANREVIEWER U FILE PLAN CHECK NO.: 14-2399 SET: III PROJECT ADDRESS: 2689 Ocean Street PROJECT NAME: Remodel/Room Addition/Deck/Stairs for Kunkle Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Mail Telephone Fax In Person REMARKS: The red-clouded notes on sheets A0,O&nd A1.02 need to be made on the City- held sets. By: Tamara Fischer for Ray Fuller Enclosures: EsGil Corporation U GA 0 EJ 0 MB 0PC 11/19/14 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In (Partners flip wit/i government for (Building Safety DATE: 11/10/14 JURISDICTION: Carlsbad PLAN CHECK NO.: 14-2399 PROJECT ADDRESS: 2689 Ocean Street SET: II U APPLICANT J URIS. U PLAN REVIEWER U FILE PROJECT NAME: Remodel/Room Addition/Deck/Stairs for Kunkle Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Morey LI EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Morey Telephone #: (760) 599-8566 Fax #: (760) 599-8901 Date contacted: ViO (by:(.. ) Email: mgpeenqineers.com ØlIaiL1 Telephone I' Fax In Person LI REMARKS: By: Tamara Fischer for Ray Fuller Enclosures: EsGil Corporation 0 GA E EJ 0 MB Ei PC 11/3/14 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 14-2399 11/10/14 Please make all corrections, as requested in the correction list. Submit THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Verify final sets of architectural sheets will be signed by designer and that the structural sheets and any new calculations will be stamped and signed by engineer and /or architect of record also. Please indicate on the plans whether the existing residence has a fire sprinkler system installed. If so, then provide a note stating that any additions/alterations will be provided with an automatic residential fire sprinkler system. Section R313.2. Unable to find a note indicating whether existing residence has a sprinkler system. b) Walls must comply with the following: If structure is not fire sprinklered then any walls within 3 ft up to 5 ft from property line must be 1 hour rated and would need to be detailed and referenced as such. Examples of one hour walls are stucco exterior with 5/8X at interior. Wood siding and cementous type siding (i.e. Hardie Boards will require additional protection (generally 5/8X under the siding). If using Hardie siding then please review their listing as they require either Hardie backer board, 7/16 Titen panels or 5/8X etc. One hour walls are required to extend from foundation to roof sheathing. Details to include how one hour wall is to be maintained thru floor framing (if applies) and how one hour is to be maintained above top plates at roof i.e. double 2x full depth blocks or full depth block and 5/8X blocks. Please reference detail 31A1.01 to the plan at new exterior wall at bedroom 2. 9. All hot water piping sized 3/4" or larger is required to be insulated as follows: 1" pipe size or less: 1" thick insulation; larger pipe sizes require 11/2 ' thick insulation. Note: In addition, the h/2' size hot water pipe to the kitchen sink is required to be insulated. ES 150.00)2 Unable to find this noted for new hot water piping. Carlsbad 14-2399 11/10/14 10. Recheck plans for tempered window locations i.e. within 2 ft of interior/exterior doors, shower/tub areas, within 5 ft radius of tubs (unless 5 ft above), within 18' of floor if exceeds 9 sq ft and stairwells if applicable. Section R308.4 4' x 3' window at existing master bath needs to be tempered as it is within 5' of the standing surface of the tub. 27. Specify on the plans the following information for the roof materials, per Section R106.1.1: Manufacturer's name and ICC approval number, or equal. Unable to find this specified on the plans. A. The scope of structural work was reduced but some information that is needed is missing from the structural plan and some information that no longer applies is still shown on the structural plan. Please revise. The engineer needs to stamp and sign the revised structural sheet(s). Provide the new header sizes for moved opening at french doors and new 4' wide window at bedroom 2. Provide a detail for new parapet (including bracing) and new roof joist to wall below shear transfer detail. Specify roof sheathing and nailing. The column and ST strap from the previous design are still shown on the framing plan. The structural note and typical detail sheets need to be included. B. It was noticed that the replaced window at the sitting I office does not comply with the requirements for emergency egress windows in section R310. (this room is considered a bedroom as it has a closet) or required natural ventilation in section Section R303.1. Please comply with the following for this room: Window must have an openable area of at least 5.7 square feet, with the minimum openable width 20" and the minimum openable height 24". The bottom of the clear opening shall not exceed 44" above the floor. Do not measure to the window sill. This generally applies to windows that have a height of 3' or less. See the figure below to see the correct method of measurement. Minimum openable area of 4% of the floor area of the room. Carlsbad 14-2399 11110/14 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes ( ) No () The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Tamara Fischer or Ray Fuller at Esgil Corporation. Thank you. EsGil Corporation In cPartners/lip wit/i government for Building Safety DATE: 09128/14 JURISDICTION: Carlsbad PLAN CHECK NO.: 14-2399 PROJECT ADDRESS: 2689 Ocean Street SET:I O APPLICANT ,JURIS. U PLAN REVIEWER U FILE PROJECT NAME: Remodel/Room Addition/Deck/Stairs for Kunkle Residence LII The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Morey EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted -Morey Telephone #: (760) 599-8566 Fax #: (760) 599-8901 ,Date contacted: c'I25 (by) Email: mqpeenqineers.com IMaiI Telephone Fax In Person LII REMARKS: By: Ray Fuller Enclosures: EsGil Corporation 0 GA 0 EJ 0 MB U PC 09/22/14 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 14-2399 09/28/14 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 14-2399 JURISDICTION: Carlsbad PROJECT ADDRESS: 2689 Ocean Street FLOOR AREA: Remodel 300 Additions 27 Deck Stairs 180 Replace Windows! Doors Stucco House REMARKS: STORIES: 2 HEIGHT: 18 ft per CRC DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION: ESGIL CORPORATION: 09/22/14 DATE INITIAL PLAN REVIEW PLAN REVIEWER: Ray Fuller COMPLETED: 09/28/14 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2013 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC, 2012 UPC, 2012 UMC and 2011 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad 14-2399 09/28/14 1. Please make all corrections, as requested in the correction list. Submit THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Verify final sets of architectural sheets will be signed by designer and that the structural sheets and any new calculations will be stamped and signed by engineer and /or architect of record also. 3. Please indicate on the plans whether the existing residence has a fire sprinkler system installed. If so, then provide a note stating that any additions/alterations will be provided with an automatic residential fire sprinkler system. Section R313.2. Projections must comply with the following: If structure is not fire sprinklered then projections (i.e. eaves/fascia) must be 1 hour rated on the underside when between two and five feet from property line. (No projections are allowed closer than 24" to property line.). Example of one eave protection is stucco, wood siding over 5/8X drywall, Hardie panels over Titen backer board or 5/8X type drywall, heavy timber i.e. 2x T&G decking over minimum 4 x 6 roof rafters, 3x fascia. Please detail and reference method choosing to applicable locations on the plans Walls must comply with the following: If structure is not fire sprinklered then any walls within 3 ft up to 5 ft from property line must be 1 hour rated and would need to be detailed and referenced as such. Examples of one hour walls are stucco exterior with 518X at interior. Wood siding and cementous type siding (i.e. Hardie Boards will require additional protection (generally 5/8X under the siding). If using Hardie siding then please review their listing as they require either Hardie backer board, 7/16 Titen panels or 5/8X etc. One hour walls are required to extend from foundation to roof sheathing. Details to include how one hour wall is to be maintained thru floor framing (if applies) and how one hour is to be maintained above top plates at roof i.e. double 2x full depth blocks or full depth block and 5/8X blocks. Carlsbad 14-2399 09/28/14 4. Please revise the section numbers and notes on the plans to match the 2012 International Residential Code (lRC), as adopted in the 2013 California Residential Code. Type of construction on cover sheet should be VB instead of UBCVN. 5. Provide stairway and landing details. Section R311.7. Maximum rise is 7-3/4" and minimum run is 10". A nosing (between 34" and 1-W) shall be provided on stairways with solid risers. Exception: No nosing is required if the tread depth is at least 11 inches. Section R311.7.4.3 Open risers are only permitted if the opening between treads does not permit the passage of a 4" diameter sphere. Section R311.7.4.3 6. Handrails (Section R311.7.7): Shall be provided on at least one side of each stairway with four or more risers. Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous. The handgrip portion of all handrails shall be not less than 1-1/4 inches nor more than 2 inches in cross-sectional dimension. See Section R311.7.7.3 for alternatives. Handrails projecting from walls shall have at least 1-1/2 inches between the wall and the handrail. Ends of handrails shall be returned or shall have rounded terminations or bends. 7. Could not determine what some of the key notes were as shown on plans. For example what is 3 as shown at proposed plan on A1.00? If these are tankless water heaters then could not locate where energy address this? 8. If applies: Note or provide the following design requirements for any new gas water heaters installed to serve individual dwelling units: ES 150.0(n) Gas piping sizing based upon a minimum input of 200,000 btu/hr. Provide complete gas isometrics to include proposed tankless water heaters. Use 200,000 BTU's for tankless design. A 120 volt receptacle accessible to the heater installed within 3' of water heaters. 9. All hot water piping sized W or larger is required to be insulated as follows: 1" pipe size or less: I" thick insulation; larger pipe sizes require 1W thick insulation. Note: In addition, the 1/2" size hot water pipe to the kitchen sink is required to be insulated. ES 150.00)2 10. Recheck plans for tempered window locations i.e. within 2 ft of interior/exterior doors, shower/tub areas, within 5 ft radius of tubs (unless 5 ft above), within 18' of floor if exceeds 9 sq ft and stairwells if applicable. Section R308.4 Carlsbad 14-2399 09/28/14 Specify on the plans: Water conserving fixtures: New water closets shall use no more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8 GPM, lavatories are limited to 1.5 GPM, and showerheads may not exceed 2.0 GPM of flow. CPC Section 403 and 408. Specify on the plans that any existing smoke alarms that are more than 10 years old will be replaced. Section R314.3.2. Show or note that a battery-operated smoke alarms will be provided in all existing bedrooms, hallways leading to bedrooms and on each floor Section R314.3.1 Show or note that a battery-operated carbon monoxide alarms will be provided outside each separate sleeping area in the immediate vicinity of the bedrooms and on each story, including basements. Section R315.2. Specify on the plans whether the existing house was built before or after 1994. For additions or improvements to a residence built before 1994, note on the plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons of water per flush, urinals that use more than one gallon of water per flush, showerheads that have a flow capacity of more than 2.5 gallons of water per minute, and interior faucets that emit more than 2.2 gallons of water per minute) shall be replaced. Certification of compliance shall be given to the building inspector prior to final permit approval. California SB407. . RESIDENTIAL GREEN BUILDING STANDARDS The California Building Standards Commission has adopted the Green Building Standards Code which became effective January 1, 2011 and must be enforced by the local building official. The following mandatory requirements for residential construction must be included on your plans. CGC Section 101.3. The Standards apply to newly constructed residential buildings, iing, with _add itions/aIteratuons that jpçréàsthj pJldJg's_conditioned are, volume or size. CGC Section 303.1.1. Provide a sheet on the plans labeled "Green Building Code Requirements" and include the following notes as applicable. Recycling. Note on the plans that a minimum of 50% of construction waste is to be recycled. CGC 4.408.1. Recycling. Note on the plans that the contractor shall submit a Construction Waste Management Plan to the jurisdiction agency that regulates waste management, per CGC 4.408.2. Operation and maintenance manual. Note on the plans that the builder is to provide an operation manual (containing information for maintaining appliances, etc.) for the owner at the time of final inspection. CGC 4.410.1. Carlsbad 14-2399 09/28/14 Pollutant control. Note on the plans that during construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC 4.504.1. Pollutant control. Note on the plans that VOC's must comply with the limitations listed in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and 4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood Products. CGC 4.504.2. Interior moisture control. Note on the plans that concrete slabs will be provided with a capillary break. CGC 4.505.2.1. Interior moisture control. Note on the plans that the moisture content of wood shall not exceed 19% before it is enclosed in construction. The moisture content needs to be certified by one of 3 methods specified in Section 4.505.3. Building materials with visible signs of water damage should not be used in construction. The moisture content must be determined by the contractor by one of the methods listed in CGC 4.505.3. Indoor air quality. Note on the plans that bathroom fans shall be Energy Star rated, vented directly to the outside and controlled by a humidistat. CGC 4.506.1. Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. Show on the plans compliance with the residential energy lighting requirements for any new lighting proposing .(Mandatory requirement): In the kitchen at least one-half of the wattage rating of the fixtures must be high efficacy with non-high efficacy fixtures switched separately. Note: Approximately 34 of the fixtures will be required to be of the high efficacy variety. In bathrooms, garages, laundry rooms, and utility rooms all fixtures must be high efficacy style or be controlled by a vacancy sensor. All other rooms require any installed fixtures to be high efficacy or be controlled by a vacancy sensor or dimmer. (Closets under 70 square feet are exempt). Outdoor lighting fixtures that are attached to a building are required to be high efficacy or controlled by a combination photo-control/motion sensor. Note: Generally a high efficacy style of fixture is fluorescent, complete with electronic ballasts. Regular incandescent, quartz halogen, low voltage and halogen MR lamps do not comply. Carlsbad 14-2399 09/28/14 26. - Include on the plans the following specifications for any new electrical devices being installed Tamper resistant receptacles required for all new locations. Weather resistant type for any new receptacles installed in damp or wet locations (outside). Arc-fault protection for all new outlets (not just receptacles) located in rooms described in NEC 210.12(B): Family, living, bedrooms, dining, halls, etc. GFCI protected outlets for any new locations described in NEC 210.8: Kitchens, garages, bathrooms, outdoors, within 6' of a sink, etc. 27. Specify on the plans the following information for the roof materials, per Section R106.1.1: Manufacturer's name and ICC approval number, or equal. 28. A please include in special inspection requirements the masonry wall. In addition the City of Carlsbad limits you to 1000 psf in designed unless a soil report is provided. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate.here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes() No () The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123: telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Ray Fuller at Esgil Corporation. Thank you. Carlsbad 14-2399 09/28/14 CITY OF CARLSBAD SPECIAL INSPECTION AGREEMENT B-45 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov, In accordance with Chapter 17 of the California Building Code the following must be completed when Work being performed requires special inspection, structural observation and construction material testing. 'rojectlPermit: Project Address: THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNERIAUTHORIZED AGENT. Please check if you are Owner-Builder 0. (II you checked as owner-builder you must also complete Section B of this agreement.) Name: (Please print) (First) (Ml.) (Last) Mailing Address: Email_______________________________________________________ Phone:________________________ I am: OProperty Owner OProperty Owner's Agent of Record DArchitect of Record DEngineer of Record State of California Registration Number Expiration Date:___________________ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspections noted on the approved plans and, as required by the California Building Code. Signature: Date: CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor I builder I owner-builder. Contractor's Company Name: Please check if you are Owner-Builder ID Name: (Please print) [First) lMI.l (Lest) Mailing Address: Email:_________________________________________________________ Phone:___________________________ State of California Contractor's License Number: Expiration Date: I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. I will nrovlde a final report /letter in compliance with CBC Section 1704.1.2 prior to requesting final Signature: Date: B-45 Page 1 of I Rev. 08/11 9 • I Carlsbad 14-2399 09/28/14 (DO NOT PAY — THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 14-2399 PREPARED BY: Ray Fuller DATE: 09/28/14 BUILDING ADDRESS: 2689 Ocean Street BUILDING OCCUPANCY: R3 U TYPE OF CONSTRUCTION VB BUILDING PORTION AREA (Sq. Ft.) Valuation • Multiplier Reg. Mod. VALUE ($) Additions Per City Est 35,000 Srucco New Windows New Doors Remodel Air Conditioning Fire Sprinklers TOTAL VALUE 35,000 Jurisdiction Code Icb IBY Ordinance I Bldg. Permit Fee by Ordinance j V Plan Check Fee by Ordinance W I Type of Review: III Complete Review El Structural Only I $310.49J I $201.821 El [1 Other Repetitive Fee Hourly Repeats EsGil Fee I $173.871 Comments: lln addition to the above an is due (.5 $fiflr:)1crJ!ie CalGreen reviev. Sheet I of I macvalue.doc + <K 00 CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 9/19/14 PROJECT NAME: Kunkel residential remodel PROJECT ID: PLAN CHECK NO: CB 14-2399 SET#: I ADDRESS: 2689 Ocean St APN: 203-140-35-00 VALUATION: $35,000 APPLICANT CONTACT: mg@peengineers.com FX-~ Tlis plan check review transmittal is to notify you of clearance by: LAND DEVELOPMENT ENGINEERING DIVISION Final Inspe ction by the Construction & Inspection Division is required: Yes 0 No For status from a division not marked below, please call 760-602-2719 F-1 This plan check review is NOMPLETE Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. nlo~LAND DEVELOPMENT ENG. 760-602-2750 Chris Sexton Kathleen Lawrence i Greg Ryan 760-602-4624 - 760-602-2741 $• -- 760-602-4663 Chris.Sexton@carlsbadca.gov Kathleen.Lawrence@carlsbadca.gov Gregory.Ryan@carlsbadca.gov Gina Ruiz Linda Ontiveros Cindy Wong 760-602-4675 760-602-2773 760-602-4662 GinaRuiz@carIsbdca.gov Linda.Ontivems@carlsbadca.gov Cynthia.Wong@carlsbadca.gov Dale Willis El r1 Dominic Fier! 760-602-2784 760-602-4664 Dale.Willis@carlsbadca.gov Dominic.Fieri@carlsbadca.gov Remarks: PLANNING DIVISION Development Services BUILDING PLAN CHECK Planning Division 1635 CITY OF APPROVAL Faraday Avenue (760) 602-4610 CARLSBAD P-28 DATE: 11/6/14 PROJECT NAME: INTERIOR REMODEL ONLY PROJECT ID: PLAN CHECK NO: CB142399 SET#:. ADDRESS: 2689 OCEAN ST APN: This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required DYes Z No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: MG@PEENGINEERS.COM For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 Chris Sexton Kathleen Lawrence Greg Ryan 760-602-4624 760-602-2741 760-602-4663 Chris.Sexton@carlsbadca.Eov Kathleen.Lawrence@carlsbadca.gov Greo-ory.Rvan@carisbadca.gov Gina Ruiz Linda Ontiveros Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.Eov Dominic Fier! 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: Plan Check No. CB142399 Address 2689 OCEAN ST Date 11/6/14 Review # Planner GINA RUlZ Phone(760)602-4675 Type of Project & Use: INTERIOR REMODEL ONLY Net Project Density: DU/AC Zoning: General Plan: RH Facilities Management Zone: 1 CFD (in/out) #_Date of participation: Remaining net dev acres:_____ (For non-residential development: Type of land use created by this permit: REVIEW #: 1 2 3 Legend: Item Complete El Item Incomplete - Needs your action El 0 Environmental Review Required: YES El NO 0 TYPE DATE OF COMPLETION: -- Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: 19 El El Discretionary Action Required: YES El NO 0 TYPE APPROVAL/RESO. NO. DATE PROJECT NO. Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: El z El Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES N, NO 0 CA Coastal Commission Authority? YES 0 NO If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): COASTAL DEVELOPMENT PERMIT REQUIRED AS THE PROPERTY IS LOCATED BE1WEEN THE SEA AND THE FIRST PUBLIC ROAD PARALLELING THE R.E.A. PLANCHECK #2: REVISED SCOPE OF WORK TO ONLY INCLUDE INTERIOR IMPROVEMENTS - INTERIOR EXEMPT FROM CDP El El Habitat Management Plan Data Entry Completed? YES El NO If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (NP/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) Z 0 El Inclusionary Housing Fee required: YES El NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES El NO El (A/P/Ds, Activity Maintenance, enter CB#, Housing Y/N, Enter Fee, UPDATE!) toolbar, Screens, Housing. Fees, Construct Housing Tracking Form (form P-20) completed YES [-I NO [-I N/As City Council Policy 44— Neighborhood Architectural Design Guidelines 1. Applicability: YES El NO Page 2 of 4 07/11 0 0 0 2. Project complies: YES 0 NOD Zoning: O 0 1. Setbacks: Front: Required 20. Shown 30.4' TO NEW ARCH OF BALCONY HANDRAILS Interior Side: Required 5' Shown 3.1' (ONLY ARCHITECTURAL PROJECTIONS SPECIFICALLY IDENTIFIED IN SECTION 21.16.120 CAN ENCROACH 2' INTO A REQUIRED) PLANCHECK #2: REVISED SCOPE OF WORK TO ONLY INCLUDE INTERIOR IMPROVEMENTS Street Side: Required Shown IL Rear: Required STINGLINE SETBACK Shown NO PROPOSED ADDITIONS IN THE REAR OF THE PROPERTY 0 0 2. Accessory structure setbacks: N/A Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Structure separation: Required Shown 3. Lot Coverage: Required 60% max Shown INFORMATION SHOWN AS LOT COVERAGE IS INCORRECT SEE ADDITIONAL COMMENTS BELOW PLANCHECK #2: REVISED SCOPE OF WORK TO ONLY INCLUDE INTERIOR IMPROVEMENTS O 0 0 4. Height: BEACH AREA OVERLAY Required 24' MAX (FLAT ROOF) Shown EXISTING STRUCTURE IS 28 FEET IN HEIGHT PLANCHECK #2: REVISED SCOPE OF WORK TO ONLY INCLUDE INTERIOR IMPROVEMENTS S., \ 5. Parking: Spaces Required 20'x20' garage Shown 11'x22' (existing non- conforming) (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required A PARKING SPACE IS REQUIRED FOR 2N0 DWELLING UNIT IF THAT OPTION IS TAKEN. PLEASE REVIEW PROPERTY TO SEE IF IT MEETS THIS CRITERIA Shown N/A Additional Comments #i. PER SECTION 21.201 COASTAL DEVELOPMENT PERMIT PROCEDURES. ANY P-28 Page 3 of 4 07/li 0 PLANCHECK #3: WET BAR SHOWS 8 LINEAL FEET, NOW COMPLIES WITH WET BAR DEFINITION. OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER GINA RUIZ DATE 11/6/14 P-28 Page 4of4 07/11