Loading...
HomeMy WebLinkAbout2696 GLASGOW DR; ; CB920166; Permit- -. .- B U ILDI N G PER MIT Permit No:,CB920166 03/13/92 1:23 ; - PrOject- No: A92007 Page 1 'of' 1 .- Development No: Job Address: 2696 GLASGOW DR Str: Fl: Ste: ' -. Perrrit Type: RESIDENTAL ADD/ALT 6786 03/13/92 0001 01 02 Parcel No: 208-112-56-00'- C PRMT 38500 Valuation: '. -36,500 -. Construction Type: VN: -- 64 Occupancy Group-.R33 - Clàss Code: Status: ISSUED Description: 500 SF ROOM ADD Applied: 02/14/92 - --. Apr/Issue: 03,713/92 - - * - Validated By: JPY Appl/Ownr. : HAHNEL, BOB ' 619 4-3-1807 - - 2692. GLASGOW-DR -CARLSBAD,CA 92008 FeesqRequired e5.11cted& Credits -- Fees: &'o.o&QJ - - Adjustments: / (\00 TcF1 i,ts:\ '- .00 - Total Fees: 6Q32'00 44al Prr1n: 215.00 - Balan e: 385' 00 - - - !!! - ----------------- Building Permit 1 330..00 Plan Check 215.00i BUILDING -TOTAL -545.00 2.50 5. 00 PLUMBING TOTAL 13.00 Enter "Y' forElectric I,s-ue F%-e ICORPORATED ,/•_. / 10.O0Y-•, Enter "Y' for Remodel (( > 1952 / i0 -oo Y - * ELECTRICAL TOTAL' 20.00 •- Enter 'Y' for Mechanical Issue' , fr> 15:00 Y -. - - - Each Hood/Fireplace - - '-'J 0 1 6-.50 -- 6.50' * MECHANICAL TOTAL . . - . 22.00- - -k - APPROVAL -i DATE 3 LLLARANCE___________ - ---. -.*.-- * -CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 - ,1 PERMIT APPUCA1TON City of Carlsbad Building Department 2075 Las Palmas Dr.., Carlsbad, CA 92009 (619) 438-1161 1. PERMIT 1YPE A - U Commercial U New Building U Tenant Improvement B - 0 Industrial El New Building 0 Tenant Improvement C -Residential 0 Apartment DCondo .Single Family Dwelling 4Addition/Alteration Duplex 0 Demolition 0 Relocation 0 Mobile Home 0 Electrical 0 Plumbing O Mechanical 0 Pool U Spa 0 Retaining Wall 0 Solar 0 Other__________ PLAN CHECK NO. EST. VAL PLAN CK DEPOSIT ________ VALID. BY____________________ DATE 6313 02/IV?2 0001 01. 02 C-PRMT . 215.00 tc1&J 2. PROJECT INFORMATION I FOR OFFICE USE ONLY Addr .l3 Building or Suite No. - Nearest cross Street GJ/L$I€J,I2 C 5 C4L iczi 3-3 02 Energy Calcs 02 Structural Calcs 02 Soils Report 0 1 Addressed Envelope ulLIIiI DESCRIPTION OF WORK NAME&, ADDRESS 4,%u) JJk S4ID CITY STATE ZIP CODE DAY TELEPHONE £j9 ç - 1'o7 NAME 5rPf/Q W SL/, ADDRESS 4s CV jo o CITY LS40 STATE 04 ZIP CODE 7,,JVGy DAY TELEPHONE S. PROPEKIY OWNER NAME 5?M ADDRESS - CITY STATE . ZIP CODE DAY TELEPHONE b. WNTEACIDR NAME ADDRESS CITY STATE ZIP CODE DAY TELEPHONE STATE UC. # UCENSE CLASS CITY BUSINESS UC. # DESIGNER NAMIji6ar ADDRESS CITY STATE ZIP CODE DAY TELEPHONE STATE LIC. # 7. WORKEHS' WMPENSA liON Workers' Compensation Declaration: I hereby allirm that I have a certificate of consent to sell-insure issued by the Director of Industrial Relations, ora certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY POLICY NO. EXPIRATION DATE so as to tç2me1ubject tc(tjie vyorkers' Compensation Iws of California any manner TE 1iPiJuIJ4 tjwner-ouliuer iieciarauorn—i nereoy airirm tnat I am exempt from me Contractors License Law for the following reason: NA I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or 1 offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects - with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section Business and Professions Code for this reason:' - (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is qmpt therefrom, and the ts for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the aMpna civil pe by ofi4t mow than five hundred dollars [$5001). A SIGNATURE ii DATE aJlaIia4 I C/ f Is the applicant or future'uilding occupant required tb-dfmit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES 13 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYES. ONO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYES 0 N IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING TI-EE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the perlormance of the work for which this permit is issued (Sec 3097(1) Civil Code). LENDER'S NAME LENDER'S ADDRESS APPLICANT CERTIFICATION - I certify that I have read the application and state that the above Tirtormation is correct. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE (flY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF I1-IE GRANTING OF II US PERMIT OSHA: An OSHA permit is required for excavations over 5,0" deep and demolition or construction of structures over 3 stories in height. - Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by - such permit is suspended or ^ndoned at any time after thlk work is commenced for a period of 180 days (Section 303(d) Uniform,Buildins Code). APPLICANT'S SIGNATURE DATE: PINK: IInance '4 . '. .. CITY OF CARLSBAD INSPECTION REQUEST PERNiT# CB9201664, FOR 08,1.05/92 INSPECTOR AREA PD .' DESCRIPTION: 500 SF. ROOM ADD. . PLANCK#CB920166 OCCGRPR3 TYPE: -RAD . .' . . CONSTR. TYPE VN JOB-ADDRESS:. 2696 GLASGOW DR r STR: FL: STE: APPLICANT: HAHNEL,, BOB . PHONE: 619 434-1807 CONTRACTOR: ... . PHONE: : OWNER: 4... . . PHONE: - .4 4 REMARKS:MH/434--6472 INSPECTOR - SPECIAL INSTRUCT 4 TOTAL TIME:,* : . CD LVL DESCRIPTION ACT COMMENTS 19 ST Final Structural 29 PL Final Plumbing -• -j . .,, -39 ,EL Final Electrical 49 ME Final Mechanical ........-- 4 ' ,_• _J I S - INSPECTION HISTORY ***** DATE DESCRIPTION , ,. ACT INSP COMMENTS '070792 Gas/Test/Rep"airs AP PD . ADD TRACER WIRE 051292 -Interior.Lath/Drywall AP PD -". -- 050592 Exterior Lath/Drywall . AP PD SCREW DRYWALL . . 050192.. Insulation . AP PD . .r :,o42892' Rough Combo. AP PD . . . ..040192, ,Ftg/Foundation/Piers . AP PD . 4 032792?.Underground/Under Floor AP PD . . . I .-. •# .',._ -. . . . . S . . ., ,. S s. .....•_ ' -. . . . . .4 -•. '1 45 4 - ESGI.L CORPORATION 9320. CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (6.19) 5601468 DATE: / 10 / t?Z . [JRU.NT JURISDICT JURISDICTION: C o CAR .LAD I_JPLAN CHECKER -FILE COPY - . PLAN-CHECK NO: /6 SET: ...LL fltjps DESIGNER PROJECT ADDRESS: LAp PROJECT NAME F1 ADcm'ON The plans transmitted herewith have been corrected where ILL!J necessary and substntially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply Lj with the jurisdiction's building codes when minor deficien- cies identified are resolved and ,,-- checked by building department staff. The plans transmitted herewith have significant deficiencies - - identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. LJ The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy.of the check list has-been sent to:. - Esgil staff didnot advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check has been completed. Person contacted:_____________________ Date contacted: . Telephone #________________ REMARKS: 4. - Al/l •VO - ESGIL CORPORAON EI GA ICM losures:- - ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 - - SAN DIEGO, CA92123 (619)560-1468 DATE:' 2 / 2 I PICANT JU JUISDICTION:, CARLSBAD []PLAN CHECKER J. DFILE COPY PLAN, CHECK NO: - 16 6 SET: -I-.- -.UPS • • EjDESIGNER .:.pQ3ECT ADDRESS: 26 '4' p•k PROJECT NAME I _4LX'/T/,/\/ : The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's bui)d1ng codes. The plans transmitted herewith will substantially comply with the jurisdiction's-building codes when minor deficien- cies identified Z are resolved and checked o' building de t_ staff The plans transmitted herewith have significant deficiencies El identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. ' The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person.. The applicant's copy of the check list has been sent to 2P/ 26 92 Esgil -staff did not advise the applicant contact person that plan check has been completed. Esgil, staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: Telephone REMARKS By:--hA V VA 0 Enclosures .ESGILCORpORATIOW Xle EGA El cm PUN CPXX NO: '1' <- I 0 FOREWORD: PLEASE READ Plan check is limited to technical requirements • contained in the Uniform Building Code, Uniform JURISDICTION: CITYOFCARLSBAD Plumbing Code, Uniform Mechanical Code, National - Electrical Code and state laws regulating energy - . - conservation, noise attenuation and access for the handicapped. The plan check is based on TO: ____-/4I-"-1 regulations enforced by the Building Inspection - - Department. You may have other corrections based - <' / '?So &ti • on laws and ordinances by the Planning Department, Engineering Department or other departments. CA q •• Present California law mandates that residential ENCLOSURES:, . construction comply with Title 24 and the following - model codes: - 1988 UBC (eff. 1/1/90) 1988 UPC (eff. .1/1/90) PROJT ' /OSk) 12, ADDRESS: 't 1990 NEC (eff. 7/1/91) 1988 UMC (eff. 1/1/90) The above regulations apply to residential 4 d construction, regardless of the code editions FLOOR AREA: OO adopted by ordinance.- STORIES: ___/ The circled items listed need clarification, modification or change. All items have to be HEIGHT: - satisfied before the plans will be in conformance - with the cited codes and regulations. Per Sec.. REMARKS: - 303(c), 1988 Uniform Building Code, the approval 'of the plans does not permit the violation of any state) county or city law. - Tospeeduptherecheckprocess,noteonthislist '-- ' ' (or a copy) _where each correction item has been FLAN CORRECTION SHT addressed i.e.. plan sheet, specification, etc. Be CITYOFCARLSBAD suretoenclosethemarkeduplistwhenyousubmit SPS FAMILY AND DUPLEX ThJELLINGS therevisedplans. Date plans. received by jurisdiction: ' ' • ,. Date plans received by Esgil Corporation: . Date initial plan check completed: - 2/4 By t'Av II) Applicant-contact person: ' -• H(A!7flf>I Telephone: 434/db7 NOTE: PAGE NUMBS ARE NOT IN S&UThCE AS PAGE HAVING NO ITDIS NEEDING (X)1R'IIONS WkE List No. 12, Carlsbad Single Family Dwelling and Duplex With All Supplements. (1988 UBC) , -: ' 1. 'pieise make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Esgil Corporation, 9320 Chesapeake Drive, Suite '208, San Diego, California 92123, (619) 560-1468. Please make all corrections on the original -7 tracings and submit two new sets of prints, and any original plan sets that may have been ',,returned to you by' the jurisdiction, to:' ' The jurisdiction's building department. .Indiate o'n the-Title Sheet of the plans, the . 4rame of the legal owner and name of person responsible for the preparation of the plans. 'SfCtlCfl 302(a)-7. All sheets * of 'plans must be signed by the perscn responsible for their preparation. (California I Business and Professions Code). Plans, specifications and calculations shall be 'signed by ' the California state licensed * engineer or architect responsible for their peparation, for plans ' deviating from conventional wood frame construction. Specify expiration date of license." (California Business and Professions Code).• I' Speéify on the Title Sheet of the plans the - .. gross 'floor area of each element of this project including dwelling, garage, carport, patio, deck and balcony. Section 302(d). Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1988 IJBC,- UMC and UPC and 1990 NEC. .'1' • Submit fully dimensioned plot plan drawn to f. scale showing location, size, and use of all , •existing and proposed structures on the lot. Identify property lines and show lot dimensions and all easements. Show location of all cut or fill slopes. Show finish floor elevations and U • show elevations of adjacent finish, grade. Show drainage' patterns with minimum slopes. Section 302(d). Indicate distance from property lines to ' - proposed building. Section 302(d). K ' - ' • , J• __;• /0. Show on the title sheet all structures, pools, f walls, etc. included under this application. Any portion of the project shown on the site plan that is not included with the building permit application filed should be clearly identified as "not included." /1. Clearly show if the lower level is a basement or a story, based on the definitions in Sections 403 and 420. Plot the finish grade (as defined) on the elevations and dimension the distance to the floor above, for story determination. On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below or sticky back. REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the - - following checked items will also require Special Inspection in accordance with Sec. 306 of the Uniform Building Code. IlDI -REQ. IF RENARXS -. - CHECD SOILS COMPLIANCE PRIOR TO - FOUNDATION INS?. STRUCTURAL CONCRETE - OVER 2500 PSI - - PRESTRESSED STEEL FIELD WELDING HIGH STRENGTH BOLTS EXPANSION ANCHORS - SPECIAL MASONRY SPRAYED ON FIRE PROOFING ' PILES/CAISSONS ' • - DESIGNER-SPECIFIED - OTHER FIRE PROT!XflON 1/ Exterior walls closer than 3 feet to property - lines shall be one-hour rated construction and have no openings. Table 5-A. ' L. .Eterior walls closer than 3 -feet to a property line shall have 30 inch parapets when the floor area per floor exceeds 1,000 square feet. Section 1709. 14'. Projections, including eaves, may not extend / more. than 12 inches into the 3 foot setback -,,fro6 the property line. Section 1710. Eaves over required windows shall be not less I . than 30 inches from the side and rear property .lines. Section 504. }4. Plastic skylights shall not be installed within I that portion of a roof located within a , distance to property line where openings in exterior walls are prohibited or required to be protected. Section 5207 (a) 7. Projections, including eaves, shall be one- / -_ hour fire-resistive construction, heavy timber 1 or of noncombustible material if they project into the 3' setback area from the property Section 1710. 0 Show -location of permanently wired smoke '- detector: a. Centrally located -in corridor or area giving access to sleeping rooms. 5.. . b. On-each story. C. In the basement. d. When sleeping rooms are 'upstairs, at the upper level in close proximity to the stair. e... In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling - . .. height 24 inches or more above the ceiling height in the hallway. S NOTE: Detectors shall sound an alarm audible in . .' all sleeping areas of the unit. Section 1210 When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided at existing bedrooms per item 19 above. Section 1210. . GENERAL RFSIDFTIAL REQUIREMENTS - 'Habitable rooms, other than kitchens, shall - contain at least 70 square feet of floor area. - At least one room shall have not less than 120 square feet of floor area. Section 1207 (b). 22. 'Windo'., area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1205 (a). Appears to be deficient in () Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms, laundry rooms and similar rooms 1/20 of area is required an minimum is 1.5 sq. ft. Section 1205 (a).Q 22 L. At least 1/2 of the common wall must be open f and have an opening not less than 25 sq. ft. nor one tenth of the floor area of the interior room if light and ventilation is being supplied from an adjacent room. Section 1205 (a). Required windows shall not open into a roofed porch unless the ceiling height is at least 7 feet, the longer side is at least 65% open, and the porch abuts a street, yard or court. Section 1205 (a). Provide mechanical ventilation capable of I providing five air changes per hour in bathrooms, water closet compartments, -laundry rooms and similar rooms if required openable windows are not provided. Section 1205 (c). j6. Note that the discharge point for exhaust air / will be at least 5 feet from any mechanical ventilating intake. Section 1205(c). 2/. Ductless fans cannot be used in bathrooms if a I tub or shower is present. Section 1205(c).4 7. No habitable room, other than a kitchen, shall be less than 7'0" in any dimension. Section 1207 (c). pc. 3/. Show that ceiling height for habitable rooms is a minimum of 71 6". Section 1207 (a). Show ceiling height. for laundry rooms, hallways, corridors, and bathrooms is a minimum of 7'0". Section 1207 (a). Dimension on the plans the 30" clear width for water closet compartments and 24" clearance in front of water closet. Section 511 (a). '4;. Glazing, in the same wall plane as a door,, must be safety glazing if within 12" of the door and less than 60" above the walking surface, unless the glazing is leaded or faceted glass. Section 5406 (d) 6. Glazing in shower and tub enclosures shall be tempered, laminated or approved plastic (including windows within 5 feet of tub or shower floor). Section 5406 (d) 5. iI -flopr- Oveo---anA al( IVinjow . . - cry-d 0.,y -1- - k'i- r'-' • * 10/2/91 . . '4,. ?- - ,- - spiral stairway details, per Section 3306 (f): . Minimum run is 7 1/2 inches measured at a point12 inches from where the treads are the narrowest. .b. Maximum rise is 9 1/2 inches. Maximum clear opening between risers is 6 inches. C. Minimum headroom is 6 feet 8 inches d:. The tread must provide a clear walking •' area measuring at least 26 inches from the outer edge of the supporting column to the inner, edge of the handrail. Spiral stairways may not •be used for required exits when- the area served is greater than 400 .' sq. ft. Section 3306 (f). ,,Provide I.C.B0. Research Report and number for /metal stairway, or submit plans and ( . calculations and approved fabricator registered - - with the-building department or note that the stairway fabrication plans shall be submitted - - : 'to and approved by the building official prior - to installation. - Exterior stairways shall not project into the 3 -- /3. . foot setback from the property lines. Section •- 3306 (n). - - - 5. The walls and soffits of the enclosed usable - space under interior stairs shall be protected - : - on the enclosed side as required for one-hour fire-resistive construction. Section 3306 (m-). . - Within units, show that corridors have a - minimum width of 36 inches. Section 3305 (b). ROOFING Specify roof slope. Roof slope is not adequate for roof type - ,- specified. Table 32-B,C,D and E. v.- Specify roof material and application. Chapter 32. 4'. -Specify I.C.B.0. or U.L. approval number for roof materials not covered in IJ.B.C., e.g., tile, etc.' Section 107. -- .'Specify minimum 1/4 inch per foot roof slope '7. for drainage or design to support accumulated -. - water. Section 3207 (a) and Section 2305 (f). 1 Show roof drains and overflows Section 3207 62 Provide skylight details to show compliance with Sections 3401 and 5207 or provide I.C.B.0. approval number. Plastic skylights must be separated from each / other by at least 4 feet. Section 5207 (a) 6. 64 Show attic ventilation. Minimum vent area is 1/150 of attic area or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents. Show reej.iireLaraa and area provided. - Section 3205 (c). MASONRY Provide fireplace construction details or note construction to ' be per attached fireplace standard drawing. chapter 37. Show anchored veneer support and connections I attached to wood in Seismic Zones 3 and 4, comply with Section 3006 (d)l and Section 2515 (a). Show ties- and #9 wire in horizontal joints. - - 0. Show height and construction details of all / masonry walls. Chapter 24. Show floor and roof connections to masonry / walls. Connection shall resist 200 pouids per lineal foot or the actual design4. load, whichever is greater. Cross grain tension or bending in wood ledgers is not permitted. Section 2310. Show a minimum 2" air space and flashing between planter and building walls. Section 2516 (c) 7. Garage requires one-hour fire protection on the garage side of walls and ceiling common to the dwelling. Table 5-B, Section 503 (d). All elements supporting floor above garage, including walls supporting floor joists, must have one-hour fire-resistive protection on the garage side. Section 503 (b)- - Show 1 - 3/8" solid core self-closing door for openings between garage and dwelling. 'Section 503 (d). - - Garages are not permitted to open into a room used for sleeping purposes. Section 1104. - • - - .- 74 An occupancy separation is not required between carport and residence, provided the carport is 8/ The soils engineer recommended that he/she / review the foundation excavations. Note on open on two or more sides and has no enclosed ( the foundation plan that "Prior to the uses above. Section 503 (a) Exception 3. contractor requesting a Building Department I. foundation inspection, the soils engineer 7. Shàw garage framing sections, size of header shall advise the building official in writing 1. over garage opening, lateral cross bracing at t hat: 1 plate line, method bracing garage front and holddowns if required. chapter 23. i. The building pad was prepared in - accordance with the soils report, - NOTE: Maximum shear panel height-to-width ratio is 3 1/2 to 1 for plywood. Table 25-I. The utility trenches have been properly 7. Doors may open into the garage only if the backfilled and compacted, and floor or landing in the garage is not more than The foundation excavations comply with I one inch lower than the door threshold. the intent of-the soils report". - : Section 3304(i). Show height of all foundation walls. chapter 7/. Provide an - 18" raised platform for any FAU, / 23. " water heater, or other device in the garage / - hich-, may generate a flame or spark. UMC 6. Show height of - retained earth, on all . Section 508, UPC Section 1310 (a). foundation walls. - chapter 23. - FOUNDATION RUTREX2TS . If cut or fill slopes exist, show distance of foundation to edge of cut or fill slopes and 7. Per soils report, note on the plan the soils show steepness and heights of cuts and fills. -. /-- classification, whether or not the soil is chapter zg. - - - expansive and note the allowable bearing value. Section -2905 (c). 6. Note on plans that wood shall be 6" minimum - / above finish grade. Section 2907 (a). . ip. The foundation plan does4not comply with the . . / soils report recommendations for this project. 87 Note on plans that surface water will drain - Please review the report and modify design, away from building and show drainage pattern -. notes and details as required to show and key elevations. Section 2905 (f). - - - compliance: . - •;, ' . . - ~8. Dimension foundation per U.B.C. Table 29A: ,•Y_• , - -- / . Floors Footing -. ). Provide notes on the foundation plan listing Supported Stenwall Width Depth Thickness F. the • soils report recommendation for . --I foundations, slab and building pad preparation. 1 6" 12" 12" - 6" - - - . - 2 8" 15" 18" 7" - I. Provide a letter from the soils engineer 3 10" 18" 24" 8" confirming that the foundation plan, grading plan and specifications have been reviewed and Foundations may support a roof in. addition to the that it has been determined that the floors. Where only a roof is supported, use - - recommendations in. -the soils report are foundation for one floor. - -•. * -- -.. properly incorporated into- the construction -. documents (when required by tJi soil report). . Show foundation sills to be pressure treated, - or equal. Section 2516 (c) 3. - - - • 9ó Show foundation bolt size and spacing Section 2907 (f) Specify size, I C B 0 number and manufacturer of power driven pins. Show edge and end - . . •,•_• • -: • distances and spacing. Section 302 (d)., - .-•• - - -. - • - . . . . • . ,- - 2/13/90 - - 6 - • •-- -,. -* 'I Detail all post-to-beam and post-to-footing I. connections and reference the detail to the plant Section 2516 (m). /5. Det'ai1 shear transfer connections, including .roof and floor, diaphragms, to shear walls. Section 2513. .Specify nail size, and spacing for • weH-s, 3-ozr and roof diaphragms. Indicate required blocking. Maintain maximum diaphragm -. dimension ratios. [Tables 25 1, .1, K and Section 4714 (d)]. C &dC6 'a.) j7.Provide truss details and truss calculations 'for this project. Specify truss identification - - numbers on the plans. . 1A. Show 1/2" minimum clearance between top plate !, of interior partitions and bottom chord of trusses. .(To ensure loading will be as designed).. - - i'h.'proviäe, roof, framing plan and floor framing plan. .Setion 302 (d). Provide framing sections through ' Section 302 (d). 17/1'. Specify all header sizes for opening over 4' ide. Section 2517 (g) 5. 1f2. - Provide calculations for main vertical and I -. horizontal framing members and post footings. Section 302 (b). ]A3; Provide calculations for lateral loads, shear f - panels, shear transfer and related. Section .302 (b)-.-,' ',• .. In Seismic Zones 3 and 4, the allowable shear / wall values for drywall in Table 47-I must be reduced 50 percent when considering earthquake loads.. This does not apply to wind loads. Footnote 1. -1/5 . Show on th plans all, structural requirements I developed in ' the structural calculations. Section 302 (d). , (See comments below or at 'end.) • .• • S •••- - ..•. t• S. Columns and posts located on concrete or / masonry floors or decks exposed to the weather I or to water splash or in basements and which support permanent structures shall be supported by concrete piers or metal pedestals projecting above floors unless approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. lt. Individual concrete or masonry piers shall I project at least 8 inches above exposed ground unless the columns or posts which they support are of approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) L • () Show location of attic access with minimum size 22" x 30". Section 3205. l/. Show draft separation for attic areas between units in a duplex. Section 2516 (f). l7. Specify plywood and/or particle board' / thickness, grade and panel. identification index: Table 25-S. l4. When roof pitch is less than 3:12, design I ridge as a beam. Section 2517 (h). l. If foundation cripple wall studs are less than / 14" high, framing shall be solid blocking, or sheathed with plywood. Section 2517 (g) 4. l. Cripple wall studs exceeding 4 feet in height shall be 3 inch by 4 -inch or 2 inches by 6 inches when supporting 2 stories. Section 2517 (g) 4. 1/4. Show plywood sheathing over exposed eaves, or I other weather exposed areas, is "bonded with exterior glue." Plywood used for exterior wall covering shall be the exterior type. Section 2516 (i), 2516(g)3. /'35. Detail truss layout for 30" x 30" attic I access, if required for equipment in the attic and detail 30" x 30" clearance through truss webs. 1. Ridges, hips, and valleys shall be at least / one size larger than supported rafters. Section 2517 (h) 3. I 4. In open beam construction, provide strap ties I across the beams at the ridge support. Section 2501 (b). S..' S -• 138 Note on the plans that "all weather-exposed lj4. Show I.C.B.O. approval number for prefab surfaces shall have a weather-resistive barrier I fireplace. Show height of chimney above roof to protect the interior wall covering and that per I.C.B.0. approval or Table 37-B. exterior openings shall be flashed in such a manner as to make them weatherproof". Section 50. Note on the plans that approved spark 1707. arrestors shall be installed on all chimneys. Section 3704(h), Title 24. MFAN1CAL (uNIFO4 MECHANICAL ODE) 151 Note on plan: Gas vents and non-combustible All heating, .ventilating, and cooling systems and piping, in walls, passing through three floors appliances shall comply with the Uniform Mechanical or less shall be effectively draft stopped at ,Code. each floor or ceiling. UBC, Section 1706 (a) 6. - l. Show the size; location and type of all heating / arid cooling appliances or systems. l/2. Provide dryer vent to outside. UMC, Section 1903. Every dwelling unit, shall be provided with heating facilities capable of maintaining a flIcAL (NATIONAL ELE=CAL DE) room temperature of 70 degrees F. at 3 feet .-"'above the floor in all habitable rooms. Show All wiring shall comply with the National " basis for compliance. UBC, Sec. 1212. Electrical Code. Note on the plans that the FAU closet or alcove 53 Show on the plan the amperage of -the I ' must be 12 inches wider than the furnace.or electrical service, the location of the furnaces being installed. UMC Section 704. service panel and the location of any sub- , panels. If service is over 200 amps, submit ..show minimum 30" deep_, unobstructed working single line diagram, panel schedule and load space in front of furnace. Section 505, UMC. calculations. -' 1/3. Furnace shall not be installed in any bedroom, Note on the plans: "Electrical outlets shall - ' / ,, bathroom or in a closet or confined space with be installed in accordance with NEC Article -. access only through such room uniess specified 210-52". - as direct vent appliance, enclosed furnace or electric heating appliance. 55 Note on the plans: "Lighting outlets Section 704 UMC. - . controlled by a wall switch shall be provided - - in accordance with NEC Article 210-70". 4. Show source of combustion air to furnace, per Chapter 6, UMC. l6. Note on the plans: "Light fixtures installed / in clothes closets will comply with NEC .l4i5. Show access to the attic containing equipment Article 410-811. / to-be minimum 30 inches by 30 inches. The -F' opening may be 22 inches by 30 inches if the = 157 Note on the plans: "Convenience outlets in equipment can be removed through such opening. bathrooms, kitchen counter top(s) within 6 , Section 708 UMC. I feet of the kitchen sink, outdoors, and in garages and basements (other than for laundry ]66. Note that passageway to the attic furnace shall and similar equipment) shall be , GFI be unobstructed and have continuous solid protected." NEC, Art. 210-8. flooring not less than 24 inches wide, not more - than 20 feet in length through the attic. 58 Note electrical system ground to be provided : Section 708 UMC. -- per NEC, Art. 250-80(a), 81(c). - 144. Show permanent electrical outlet and lighting PLUMBING (UW1POJ( PLINBING a)DE) / fixture controlled by a switch for furnace located in attic or underfloor space. Section ..Show water heater size; type and location on 708 & 709 UMC. - / plans. UPC, Section 1301. ],L8. Show details to comply with Section 709 for - furnace under the floor, or Section 710 for - •' - roof or outside furnace. ; '•• 10/2/91 ' - •- '..,- ... -. .- •- - Yo. • Show source for providing combustion air to l7'. Provide insulation in walls and ceiling to fuel burning heater. If water wall openings in / achieve SIC of 50 between garage and living an enclosure are used, at least one-half of the area if garage use is not controlled by . required opening area shall extend into the resident. Title 24. upper twelve inches of the enclosure and one- half within the lower twelve inches. UPC, ENERGY CX)NSVATION / Section 1307. 171. Provide plans, calculations and worksheets to 101. Fuel 'combustion water heater shall not be / show compliance with current energy standards. installed in bath or bedroom or in a closet opening into bath or bedroom. UPC, Section 72 The regulations require a properly completed ' 1309. • and properly signed Form CF-lR to be either • - imprinted on the plans, taped to the plans or - ,- i%2. Provide adequate barrier to protect water "sticky backed" on the plans, to allow the heater from vehicle damage. An 18" platform building inspector to readily compare the for the water heater does not satisfy this actual construction with the requirements of requirement. UPC, Section 1310. the approved energy design. .V', -, . V Show I and P valve on water heater and show V3. All energy items shown on the plans must be in route of discharge line to exterior. agreement with the information shown on the UPC,.Section 1007 (e). properly completed Form CF-1R. /14._Show-that water heater is adequately braced to / '1/4. Specify on the building plans all of the resist seismic forces, when not connected by /-' mandatory energy conservation requirements as '-. _rigid pipe. C Section 504(d). I listed on the enclosure titled, "Mandatory / 15. V Show shower stall can accommodate a 30" circle Energy Conservation Requirements". . •'°.f and has a minimum floor area of 1,024 sq. in. ]/5. Show the make, model and efficiency of the UPC 909 (d).V ( space heating (or cooling) system and provide V V heat loss calculations if the output exceeds V 16. Provide clothes washer hook-up for each unit. 45,000 BTU/Hr. E V V / Title 24, Part 3. water closets and associated flushometer of /6. For room additions, show that the gling area7.'New the addition does not exceed 16% of the V V H'valves, if any, .shall use no more than 1.6 newly-conditioned floor area, plus glazing gallons per flush and shall meet performance removed or relocated due to the addition. standards established by the American National / V • V ,Standards Institute Standard A112.19.2, and ],fl7. Provide fluorescent general lighting in V V urinals and associated flushometer valves, if / kitchen(s) per CAC,. Title 24, 2-5352(3). V any, shall use no more than one gallon per V V flush and, shall meet performance standards CARLSBAD S.F.D. & DUPLEX SUPPLEMENT V V - established by the American National Standards / • Institute Standard A112.19.2. H & S Code, 778. Energy conservation design should be for Zone 4V V, Section 17921.3(b). V / 7. V NOISE INSULATION (DUPLEXES) 3I9. Floor drains must have auto-prime. (city - policy). - 18. Show details of duplex coon (party) walls and / / floor/ceiling assemblies to achieve a Sound ]$0. For gas piping under slabs that serve kitchen V .TransmissiOn Class (SIC) rating in walls of 50 I island. cooktops, see the attached Policy 91-46 decibels and an Impact Insulation Class (IIC) for special sleeve and clean-out requirements, rating on floor/ceiling of 50 decibels.. / V Title 24. Note exhaust fans cannot be ductless type - '/ 9. / . . . ' (city policy). ; J6 'penetrations Show how penetrations of assemblies for piping, / electrical devices, recessed cabinets, l'2. New residential units must be pre-plumbed for - bathtubs, soff its, or heating ventilating, or / future solar water heating. Note "two roof -. exhaust ducts shall, be sealed, lined, or - insulated to •. maintain required sound jacks must be installed" where •the water heater is in the one story garage and directly - -- • , transmission rating. Title 24. below the most south- facing roof (City - . Ordinance No. 8093). 'V ',• . .'.- • V "'•• '• ••V 7-7 - ,• - V - - - 1/17/92 - • . 10 I ,• - - V V X13. Note "two 3/4" copper pipes must be installed to the most convenient future solar panel 15/2. Only tank-type water closets that use an average of 1.6 flush / gallons of water per or location when the water heater is not in a one less, and urinals and associated flushometer • story garage and is not directly below the most valves, that use an average of 1 gallon of • south facing roof. (City Ordinance No. 8093). water per flusn or less shall be installed in l. All piping for present or future solar water new construction. These provisions shall apply to existing buildings only when toilets '7 heating must be insulated when in areas that are being replaced in existing bathrooms or are not heated or cooled by mechanical means installed in new bathrooms. • (city policy). -. P(ISCilLANa)US / Incorporate the waterproofing details, on the attached Policy 80-8, where interior living / 13. Please see additional corrections, or remarks, space occurs below grade at the masonry on the following page. wall(s). - 94 To speed up the recheck process, note on this 186 Show on the Title Sheet on the plans, the list (or a copy) where each correction item information required by the attached has been addressed, i.e., plan sheet, note or Developmental Services Sheet 112383. detail number, calculation page, etc. -. 87 Ali new' residential buildings, including Please indicate here if any changes have been • additions, require a soils report. Please made to the plans that are not a result of • submit two copies. Exception: If a room corrections from this list. If there are addition is limited to one story and 1000 sq. other changes, please briefly describe them • ft. in area, then a soils report is not and where they are located in the plans. required. Eg1 Corporation will advise the - City to place their soils notice stamp on th Have changes been made to the plans not - plans. resulting from this correction list? Please check. Heavy timber framing, minimum 6" x 10" beams / and minimum 8" x 8" post, for the structural ' Yes No beam and column supporting the fire separation - - between -the- garage and living area above, is The City of Carlsbad has contracted with Esgil acceptable if shown, on the plans. (city Corporation located at 9320 Chesapeake Drive, Suite policy). •., 208, San Diego, California 92123; telephone number - ' 619/560-1468, to perform the plan check for your 19. All structures require a Class B roof covering, project. If you have any questions regarding these 2 / except room 'additions. If a room addition plan check items, please contact__________________ covers all of the existing building (2nd story . addition), then the above exception doesn't apply. * U1 P City Ordinance 9792 requires two parking spaces/unit with clear area of 201 x20' i.e. no at Esgil Corporation. If you have any questions .washing machines, etc. Show compliance, regarding City Building permit procedures, please - ' contact Carter Darnell at the City of Carlsbad, 91 All chimneys 'attached to any appliance or 2075 Las Palmas Dr., telephone 619/438-1161. fireplace that burns solid fuel shall be equipped with an approved spark arrester. The Thank you. -J net free area of the spark arrester shall be not less than four times the net free ara of Enclosures: • - • - , the outlet of the chimney. The spark arrester • screen shall have heat and corrosion resistance equivalent to 12 gauge wire,, 19 gauge , galvanized wire or 24 gauge stainless steel. Openings shall not - permit the passage of • spheres having a diameter larger than 1/2-inch - and shall not block the passage of spheres - • having a diameter of less than 3/8-inch. 3.. ',•••• • • _ .•-,•,_* - •- - •*, & 'V V - 1/17/92 • - 1], - -. • • • Date : - Jurisdiction CARLSBAD -Prepared 'by _y, VALUATION AND PLAN CriECKEE PLAN CHECK NO. BUILDING ADDRESS 6 tAs4 APPLICANT/CONTACT 3b __hhe/ ':; BUILDING OCCUPANCY _________________ TYPE OF CONSTRUCTION Bldg. Dept. Esgil IMF PHONE NO. 4-/a7 DESIGNER PHONE______________ CONTRACTOR PHONE____________ BUILDING PORTION BUILDING AREA VALUATION ?ULTI'PLI'R VALUE °_I /f VlI _ T_ ______________ ___________ 1 AirConditioninH Commercial Residential Res. or Comm. Fir.e_Sprinklers Ttal Value 1 • - BUILD±NG PLANCHECK * ENGINEERING CHECKLIST - DATE 2-4--Z. E-' ITEM COMPLETE PLANCHECK NO. ITEM INCOMPLETE NEEDS YOUR ACTION .3 2 3 V 6 2' ITEM SELECTED'- -I S T D D 't?5 rA 1AxrnO.J CC•C PROJECT ID:A4L)—'2-S - -H:; ST V,LL1S' , C C1 C •LEGAL REQUIREMENTS V K- K K Site Plan V Provide a 'fully dimensioned site plan drawn to scale. Show north arrow, property lines, easements, existing and r proposed structures, streets, existing street improvements, right-of-way width and dimension setbacks E E 2 Show , on site plan Finish floor elevations, pad elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and - V proposed slopes, driveway '-with percent (%) grade and: drainage patterns 3 Provide legal description and Assessors Parcel Number. / , Discretionary Approval Compliance r: LJ LJ L_J 4• No Discretionary approvals were required. ii i • nL_Jm LJ L.J 5 Project complies with all Engineering Conditions of Approval for Project No :6 Project does not comply with the following Engineering Conditions of Approval for Project No V - - Conditions complied with by Date: Field - Review 7 Field review completed. No issues raised El El 8 Field review completed. The following issues or- discrepancies with the site plan were found A Site lacks adequate public improvements B Existing drainage improvements not shown or in conflict with site plan El E E C Site is served by overhead power lines .2 ,. •_V -• V• V - V V P:\DOCS\MISFORMSWRMOOIO.DH V V V REV. 02/27/91 - •- t t V V -. - - -•: -. VV • • V .• -V V • V • V - -•V- D. Grading is required to access Site, create pad or, provide for ultimate street improvement. E E E. Site access visibility problems exist. Provide onsite turnaround orengineered solution to problem. F Other Dedication Requirements VE:1 9. No dedication required 10 Dedication required Please have a registered Civil * Engineer or. Land Surveyor prepare the appropriate legal description together with an 8½" x 11" plat map and submit with a title report and the required processing fee. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit The description of the dedication is as follows:_________________________ ' lr - Dedication completed, Date By _•:7. • -. * - 0 Improvement Reaujrements ii. No public improvements required. SPECIAL NbTE: Damaged or defective improvements found adjacent to building site must * be repaired to the satisfaction of the City inspector prior. - - . to-Occupancy, —ir-i Public improvements required. This project requires construction of public improvements pursuant to Section 18.40 of the City-Code. Please have a registered Civil - . Engineer prepare appropriate improvement plans and submit for separate plancheck process through the Engineering - * - Department. - Improvement plans must be approved, -. appropriate securities posted and fees paid prior to issuance of permit The required improvements are:- Improvement plans signed, Date:by - P\D0CS\M1SF0RMS\FRMO010.0N . • REV. 02/27/91 -s 13: Improvements are required. Construction of the public 4 improvements may be deferred in accordance with Section • 18.40 of the City Code. -Please submit a letter requesting deferal of the required improvements together with a. recent title report on the property and the appropriate -, • processing fee so we may prepare the necessary Future..- Improvement Agreement. The Future Improvement Agreement must be signed, notarized and-approved by the City prior to issuance of a Building Permit Future Improvement Agreement completed, Date By: . 13a. -Inadequate information available on site plan to make a determination on grading requirements Please provide more • detailed* proposed and existing. elevations and contours. -. Include accurate estimates of the grading quantities (cut, - fill, import, export) No grading required as determined by the information Provided on the site plan - . - -•J .4 E -E 4 - 4 Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted for -- . s separate plan check and approval through the Engineeringt - S • Department. NOTE: The Grading Permit must be issued and. 4 - :grading substantially complete and found -acceptable tothe - - City Inspector prior to issuance of Building Permits .4.. .• . Grading Inspector sign off. Date:____by Miscellaneous Permits 16..Right-of-Way Permit not required 17-. Right-of-Way Permit required. A separate Right-of-Way.' • Permit issued by the Engineering Department is required for.-. thefollowing:- - • . 'S , - - • 18 Sewer Permit is not required 19 Sewer Permit is required. A sewer Permit is required • - concurrent with Building Permit issuance. The fee required is noted below in the fees section 20 Industrial Waste Permit is not required. - I. . -. . - . 5 - - . p \00cs\ 0S\0010 OH REV 02/27/91 5_.•. - - - - - .4 21. Industrial Waste Permit is required. Applicant must complete Industrial Waste Permit Application Form and submit' for. City approval prior to issuance of a Building • . - Permits. Permits must be issued prior to occupancy. . 4 , Industrial Waster Permit accepted - Date:-- —By Fees Reauired J. .-..•.- • - :27. Park-in-Lieu Fee S '. Quadrant: Fee per Unit: Total Fees 'EJ 23 Traffic Impact Fee ' •. Fee Per Unit: Total Fee: F - •• 0 . 24. Bridge and Thorough fare Fee • Fee Per Unit: Total Fee:• - 0-. 25 Public Facilities Fee 4 required 11 I'-yA 0 26 Facilities Management Fee-Zone:Fee 27 Sewer Fees Permit No.EDU's_______ I Benefit Area: Fee .•• I 28.'Sewer Lateral Required I Fee: .• 4-. I 0 J_ 29 REMARKS - -r -- .54 .5 -5 - •:-. - - - - '•- - • • -. 4 ''7' 5_.,•_ • • . . ENGINEERING AUTHORIZATION TO ISSUE PERMIT S ' • BY: 't4hi21JfL4 DATE Q -24 -qz 74 r 54 5,. ••,. - S. -- - -, '5• - - - 'St • •_ , • S. • _ . S • S S #.t - '- -- .5__ . . ;, .-• • P:\D0CS\N1SF0RMS\FRK0010.DN REV 02/27/91 4 l - .- -. PLANNING CHECKLIST . Plan Check No. Address lq j eaz Lj Dr. = Planner Dail Phone 438-1161 ext. -/3 2_2 - - (Name) APN: J)-5 Type of Piojectnd Use. Zone Facilities Management Zone Vp . .. S.. Leend. ' • . f21 item Complete : cc ,LJ Item Incomplete - Needs your action -. - 1, 2, 3 Number in circle indicates plancheck number where deficiency, was - identified El 12 Environmental Review Required: YES — NO - TYPE._______ • - bATE OF COMPLETION: ' A. . Complianceith conditions of approval? If not, state conditions which require action. -, Conditions ofApproval \.. S. - Discretionary Action' Requid YES NO E APPROVALJRESO NO DATE -. 'PROJECT NO.________ -. 5, . • OTHER RELATED CASES:.,.-. . Comphance with conäitiors of approval If not, state conditions which require action. ' - Conditions of Approval,I -S. ,. '. ,-'k. ••.. . .= •5•'• • . 'S. '•• •'• S. - . . - .. El California Coastal Commission Permit .Required YES - NO - DATE OF APPROVAL: - ç \ - , • , .s\ -s - • - " \ ''- J San Diego Coast Distnct, 311 Lanuno Del Rio North, Suite 200, San Diego, CA 92108-1725 (619) 521-8036 . * Compliance' with conditions of approval? If not, state conditions which require action: Conditions of Approval Comments -- JI E =M Landscape Plan Required YES NO See attached submittal rquirements for landscape plans:- ( Site Plan: 1. Provide a fully dimensioned sitè plan drn to scale. Show: North. arrow, property lines, eâsemeñts, - existing and proposed structures, streets, existing street improvemenis,. right-of-way width and dimensioned setbacks. 2 Show on Site Plan Finish floor, elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes and driveway. - I 3 Provide legal description of property. 4. Provide assessor's parcel number. - Zoning: . -. 1 Setbacks Front Required ' / Shown ZI' mt Side Required 5' Shown 7' Street Side: Required - 4 - Shown 44- * Rear Required I / ' Shown 2 '/' -F '0 - 2. Lot coverage: ,' R~equired . -L) Shown'/ 3 Height Required 37 Shown 1.2" Parking Spaces Required & Shown Guest Spaces Required - . _ - Shown 4. CERTIFICATION OF COMPLIANCE - CITY OF CARLSBAD Plan Check No - DEVELOPMENT PROCESSING SERVICES DIVISION 2075 LAS PALMAS DR., CARLSBAD, CA 92009 * . (619) 438-1161 This form shall be used to determine the amount of school fees for a project and to verify that the project, applicant .has complied with .the school fee requirements. No building permits for the projects shall be issued until the certification is signed by the appropriate ':school district and returned to the City of Carlsbad Building Department. ,,SCHOOL DISTRICT - Carlsbad Unified ' San Marcos Unified ( \. 801 Pine'Avenue . 1290 West San Marcc,s Blvd. Carlsbad, CA ..92009 (434-0610) . San Marcos, CA 92024 (744-4776) Encinitas Union' San Dieguito Union High School 101 South -Rancho Santa Fe Rd. -. 710 .Encinitas Boulevard Encinitas, CA 92024 (619) 94f4t-430u Encinitas, CA 92024 (753-6491) . 57Z Project Applicant Fl .4 /fL A P N Project Address: 2 kQ GL.s4 Sc,c.-'-' RESIDENTIAL SQ. FT of living area number of dwelling units___________ SQ. FT of covered area SQ. FT of garage area______________ COMMERCIAL/ INDUSTRIAL: SQ; FT. AREA______ Prepared Date 2---------------------------------------------------------------------------------------- FEE CERTIFICATION (To be completed by the School District) • • 1 __Applicant has complied with fee requirement under Government Code 53080 Project is subject to an existing fee agreement . -. i_. I - - ..• • • • -. •- -( Project is exempt from Government Code 53080 FinàlMap approval and construction started before September 1, 1986. (other school fees paid) - ____Other 'Pc k SLkQ ds 5(O Residential. Fee Levied: $ . -. based on sq. ft. @_________________ Cornm/lndust Fee ...Levied :'$ ____based on sq. ft @________________ School District Official . . ' Title Date AB 2926 and SB 201 fees are'capped at $1.58 per square foot for residential AB 2926 is capped at 26 per, square foot for commercial /industrial. - •, • I 4 '•'- . - • -. • - • •,. -. -. •1. -S . -t .. • .5, ,• ;', 5, 5 A - IF • • - - -F- • - '• -•*- •••5.- 5