Loading...
HomeMy WebLinkAbout2701 HIGHLAND DR; ; 85-613; PermitT'. . USE BALL POINT PEN ONLY & PRESS HARD 0 I hereby afflrm that Lam licensed under o provisions of Chaper 9 (commencing with Section 7000) of Division 3 of the Business and Profe8aions Code, and my license is in I full force and effect. Lrc. No. Class - o 0 -. hereby affirm thai i am. exempt 1mm the Contrac t or's License Law for the following reason (Sec. 7031.5 Business and Professions Code: Any city or county which re- quires a permit to construct, alter, improve, demolish, or I repair any structure, prior to its issuance also requires the ap- plicant for such permit to tile a signed statement that he is licensed pursuant to the provisions 01 the, contractor's I License Law (Chapter 9 commencing with Section 7000 of Division 301 the Business and Professions Code) or that is ex- empt therefrom and the basis for the alleged exemption.' Any I violation of Suction 7031.5 by an applicant for a permit sub-jects the applicant to a civil penalty 01 not more than live hun- dred dollars ($500). • ...' _, . I, I, as owner 01 the properly, or my employees with wages as their solo compensation, will do the work, and the struc- ture is not intended or uttered for sale (Sec. 7044. Business and Professions Code: The Contractor's License Law does 5 not apply to an owner 01 property who builds or improves I m thereon and who does such work himself or through his own employees, provided that such improvements are net intend' Sal ad or offered for sale. It, however, the building or improve- I Z moot is sold within one year 01 completion, the owner-builder 39 will have the burden 01 proving that he did net build or im' O prove for the purpose of onto), . I. as owner of the property, am'enclusivnly contracting with licensed contractors to construct the project (Sec. 7044,, 1 Business and Professions Code: The Contractor's License Lawdoes net apply Ivan Owner 01 property who builds or im' proves thereon, and who contracts for each projects with a I (0 . contractor(s) license pursuant to the Contractor's License Z Law(. .. . - tJ As a homeowner I am improving my home, and the 10110w' ing conditions exist: cc 1. The work is being performed prior to sate. II 2. I have lived - in my home for twelve months prier In completion of this work. w . .3, I have not claimed this' exemption during the I 0 last three years. ' • . . I tam exempt under Sec. _________________ B & P.C. I for this reason C) thereby affirm that I haven certificate or consent In I snll.insure. or a certificate or Work 'Compensation s~rance. or a certified copy thereof 380D. Labor Code In. - / a POLICY, NO., (,,.4' CERTIFICATE OF EXEMPTION FROM It WORKERS' COMPENSATION INSURANCE (This section seed not be 6ompleted it the permit I is for one hundred dollars ($100) or less) $ ,, 0 r certify that in the performance of the work for which I this permit is issued. I shall not employ any person in any manner Sn as to become subject to the Workers' Compen. t satins Laws 01 California. - NOTICE TO APPLICANTt.It, alter making this Certificate Compensationprovisions or the Labor Code, you mast ,. forthwith comply with such provisions or this permit shall 'he deemed revoked. _ ' * .. I, I tMreby abtirm that there isa 0005tractine lending e Ix 'ageny for the pertormance 01 the work for which this per. pit is' issued (Sec. 3097. Civil Code) , wI: Lender's Name - . .Lender's Address_. APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS. CARLSBAD BUILDING DEPARTMENT - . , . APPLI TI & PERMIT Carlsbad, California 92008-1989 (619) 438.5525 - JOB ADDRESS , AV. ST. RD. NEAREST CROSS ST. DATE OF APPLICATION1 016S I IN E NSE -' VALUATION ' PERMIT NUMBER h V-0 LICks io e --s L//? 3 b ZONE' LOT I BLOCK SUBDIVISION,.- S SJDR PARc0EL NO. (0 /IDf CONTRACTOR OWNE R'S PHONE CONTRACTORS PHONE OWNER'S NAME CONTRACTOR'S&DORESS( LICENSE NO. . PLAN 1,0. # BUlL HG OOTAGE -- / - OWNERS MAILING AT ES DESIGNER . DESIGNER'S PHONE DESCRIPTION OF-lJORK DESIGNER'S AOESS I.,J LICENSE NO. F/P FLRELEV NO ''' 090GP - EDU TO763G6 9OO E—.K 'L)( -vO ND Y 0008 I0/8 OiQ - - ' CENSUS TRACT GP,LA1c USE PARKING SPACE RES UNITS GRADING PERMIT ISSUED REDEVELOPMENT T'41E I 0CC LOAD' R FIRE SP . I . .. - ' y o o AREA S VN - YDN ' - Not Valid Unless Machine Certified -' QTY. PLUMBING PERMIT- ISSUE ' QTY. MECHANICAL PERM(T -ISSUE .3 , , SUMMARY/ACCOUNT NUMBER . EACH FIXTURE TRAP ' /7 4 INSTALL FURN. DUCTS'IJP TO 100,000 BTU . , — BUILDING PERMIT . - 001-810'00-00-8220 / EACH BUILUiNi SEWER .. OVER 100,000 BTU . SIGN PERMIT 001-810-00'00-8221 EACH WATER HEATER'AND/OR VENT " BOILER/COMPRESSOR UP TO 3 HP . ' '. PLAN CHECK . , 001'810-00'00-8806 - EACH GAS SYSTEM I T4 OUTLETS ._- -. "2_I BOILER/COMPRESSOR 3.15 HP - , , TOTAL PLUMBING ' 001-810-00-00-8222 - - EACH GAS SYSTEM 5 OR MORE , METAL FIREPLACE ' - ELECTRICAL '. 001-810-00-00-8223 EACH INSTAL,. ALTER, REPAIR WATER PIPE . . - VENT FAN SINGLE DUCT - MECHANICAL 001-810'00-00-8224 EACH VACUUM BREAKER . , . MECH EXHAUST - HOOD/DUCTS -' , MOBLEHOME ' 001-810-00-00-8225i. WATER SOFTNER - -- ' RELOCATION OF EA FURNACE/HEATER - , .. , MOBILEHOME PARK INSP '. - EACH ROOF DRAIN (INSIDE) ' - '. -' - ,- SOLAR ' - . 001'810-00-00-8226 1 . • ______________________________ - . . . ' ' • . TOTAL MECHANICAL . ' ' - . ' STRONG MOTION \ TA:L PLUMBING,- -' I •- FIRE SPRINKLERS ' 001-81000008227 If PUBLIC FACILITIES FEE 33281000008930 OTY 'ELECTRICAL PERMIT ISSUE,j-... QTY SOLAR ISSUE ; NEW CONST EA AMP/SWT!BKR . - ' COLLECTORS - - ' SCHOOL FEE -'DISTRICT 1PH ' 3 P ' ' . STORAGE TAWS . ' CaISbad . - . • - - Exisi BLDG EA AMP/SWT/BK P - ROCK STORAGE. . - . - _ Encinitas - 1 PH- - ,. 8 r, , - PH ' ' . PUMP . ' - Sac Diegoilo REMOOEL.'ALTER PR CIRCUIT - - 4f" ' PLAN CHECK FEE ' -- - !San Marcos' - TEMP POLE 200 AMPS . C , , . - , • . • ' : - ., - . .• . - OVER 200 AMPS ' I LICENSE TAX 001-810-00-00-8162 - ,' 01 Enemptiun. you should become subject In the Workeix' TEMP OCCUPANCY (0 DAYS) ., ' . MIFF .880 5199257 /// , CREDIT DEPOSIT TOTAL ELECTRICAL " I TOTAL SOLAR TOTAL FEES P/' /0 I HAVE CAREFULLY EXAMINED THE COMPLETED "APPLICATION AND PERMIT" AND DO HEREBY Expiration. Every permit issued by the Building Official under the provisions Otthis * AN OSHA iT IS REQUIRED FOR EXCAVATIONS OVER CERTIFY UNDER IPENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE Code shall expire by limitation and bsuchetsnot become null and void. It the building or work s' o" DE AND DEMOIJTION OR CONSTRUCTION OF authorized menced within 180 days from the date of such DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT IS permit Or it the buildina or work authorized by suspended or STR(.IC RES OVER 3 STORIES IN HEIGHT ys. ISSUED: TO COMPLY WITH ALL ITY. COUNTY AND STATE LAWS GOVERNING BUILDING CON abandoned at any time a(er the work is commenced for 'od of 180 da STRUCTION. WHETHER SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND APPLICANT'S SIGNATURE o CONTRthR' APPROVEf BY \ • DJN KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS. COSTS 0 f EXPENSES WHICH MAY IWANY WAYACCRUE AGAINST SAID CITY IN CONSEQUENCE OF,THE - BY PHONEGRANTING OF THIS PERMIT. -• -. -- .- - . - . a,. •, .- 4 ' r - - - " '\__,/J ..), '., - - VV .. V' i FIELD INSPECTION RECORD . REOUIREDSPECIAL INSPECTIONS V ' V INSPECTOR'S NOTES 'N ••' * - 'V - INSPECTI ON REQ IF INSPECTOR'S DATE '- - T. CHECKED APPROVAL . SOILS COMPLIANCE PRIOR TO FOUNDATION INSP - - STRUCTURAL CONCRETE - - -. . . •, OVER 2000F'Sf PRESTRESSED -- CONCRETE POST TENSIONED CONCRETE FIELD WELDING HIGH STRENGTH BOLTS V SPECIAL MS\ON) . ' ,\ V V •. , - PILES CAISSONS IV _____________________ _____________ V V 'VV' ' • I - /V' - ' ' . - - -. V V - V ________________ - ',,VJ* S V I TYPE . ',:,INSPECTOR. BUILDING FOUNDATION PDATE.%_ REUFORCEb STEEL MASONRY GUNITE OR GROUT V SUB FRAME Li FLOOR Li CEILJNG SHEATHING ROOF. p.SHEAR C• FRAME EXTERIOR LATH INSULATION' INTERIOR LATH &DRYWALL V PLUMBING I, Li SEWER AND BL/CO Li P1/CO; UNDERGROUND DWASTE DWATER TOP OUT DWASTE LiWATER 24.J /cfi TUB AND SHOWER PAN GAS TEST Li WATER HEATER Li SOLAR WATER ELECTRICAL O ELECTRIC UNDERGROUND JJFFER K -g4f. /k1s. ROUGH ELECTRIC I •.," o ELECTRIC SERVICE Li TEMPORARY Li BONDING Li POOL MECHANICAL Li DUCT & PLEM., Li REF. PIPING . ti V) HEAT —AIRCOND.SYSTEMS VENTILATING SYSTEMS CALL FOR FINAL INSPECT7ON WHEN ALL APPROPRIATE ITEMS ABOVE HAVE BEEN APPROVED. ,' ; - FINAL PLUMBING '. - ELECTRICAL V V MECHANICAL GAS BUILDING 3' SPECIAL CONDNS. 5' PLAN CHECK MUMBER ( ADDRESS01.-DATE /t PLANNING_ TYPE OF STRUCTURE ZONE .SCHOOL FEES:' 'SAN DIEGUITO ENCINITAS s 17 CARLSBAD SAN MARCOS % COVERAGE_________________________________ REQUIRED SETBACKS______________ BUILDING HEIGHT__________________________ FRONT _S FENCES/WALLS________________________________ SIDE -- STWO CAR GARAGE - REAR COMMENTS: REDEVELOPMENT ArPOVAL REQUIRED rC= Lu LANDSCAPE PLAN COMMENTS c EtVIflOENTAL REQUIRED_____________________________________________________________ _ _ _ ADDITIONAL COMENTS__________________________________ AL,OK TO ISSUE: 1-DATE: FINAL: DATE: - •• ENGINEERING LEGAL DESCRIPTION VERIFIED?-- A.P N CHECKED?_...J S P.F.F. S PARK IN LIEU S R.O.W: IMPROVEMENTS: EDU SEWER:' LATERAL - DRIVEWAY f GRADING PERMIT DRAINAGE: - EASEMENTS: ADDITIONAL COMMENTS uj CD w 0 . . OK TO ISSUE:- DATE * ENGINEERING INSPECTION REQUIRED PUBLIC WORKS 'INSPECTOR:. FINAL OK DATE * IF THIS ITEM IS NOT CHECKED, BUILDING DEPARTMENT WILL MAKE ALL INSPECTIONS (DRIVEWAYS, CURB CUT, DRAINAGE, ETC.) . ESGIL CORPORATION '. -• * 9320 CHESAPEAKEDR., SUITE 208 SAN DIEGO. CN92123 - (619) 560- 1468 .4 DATE 2- DAPPLICANT • RISDICTIO' - '• - JURISDICTION: AWCHECKER 9 FILE COPY PLAN CHECK-NO: DUPS V SV•• . - 0 DESIGNER PROJECT ADDRESS PROJECT NAME - , , I The plans transmitted herewith have been corrected where V • V V V necessary and substantially comply with the jurisdiction's building codes .- •:: -.: .The plans' transmitted herewith will substantially comply V' with the jurisdiction's building codes when minor deficien- ,. .èies identified -. • are resolved and V ' • V checked by building department staff. The plans transmitted herewith have significant deficiencies U identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is the jurisdiction's 0 copy for your information The plans are being held at Esgil-Corp.-until corrected plans are submitted for recheck '. •The applicànt'scopy of the check list is enclosed for the V jurisdiction to return to the applicant contact person. V The applicant's copy of the check list has been sent to: Cl -. Esgil staff did not advise the applicant contact person that plan check has been Completed.. S ' Esgil staff did Advise applicant that the plan check has been completed. -Person contacted: 'Date contacted: Telephone REMARKS: . -5- • - -• - ,•V -4 V V// •V *'S* ;,1' S BY ..A' é,, ( 'j-- ENCL * ESGIL 'CORPORATION - - • .. S.) ' V 2 , • V V ' ..-'- 4' I S .5 ESGIL- CORPORATION 9320 CHESAI'E.KE DR.. SUITE 208 SAN I)IEGO. CA 92123 (619) 560.1468 DATE: / / -)APPLICANT JURISDICTION JURISDICTION: []PLAN CHECKER PLAN E]FILE COPY CHECK NO:' . JUPS 0 DESIGNER PROJECT ADDRESS: '- 701 PROJECT NAME: 77 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's . . building codes. S The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- El cies.identifjed are resolved and' - áhecked by building department staff'. The plans transmitted herewith have significant deficiencies -. . - identified on the enclosed check list and should be corrected -: and resubmitted for a complete recheck. ' •_ . d - ' The check list, transmitted herewith is the jurisdiction's fl. copy for your information. The plans are being held at . •. • Esgil Corp.-until corrected plans are submitted for recheck. : .Theaplicant's copy of the check list is enclosed for the jurisdiction to return 'to the applicant contact person. The.aplicant's copy of the check list has been sent to: • ,- Esgil staff did.not advise the- applicant contact person that . plan check has been completed. ' - . Esgil ,staff did advise applicant that the plan check' has. been completed. Person contacted: Date contacted: Telephone REMARKS: S . _______ S • . / - --- BY:' ENCL______ . . EsdtL CORPORATION Lgw Me PLAN (1X NO. 6 "3 FOREWORD: PLEASE READ A Plan check is limited to technical requirements .JURISDICflON: S contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, .. . . _______________________________________________ National Electrical Code and state laws regulating energy conservation, noise - . . . . _• attenuation and access for the handicapped. TO: /i4 T 2-4 r'- The plan check is based on regulations enforced by the Building Inspection Department. You may, . - .. have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. . H- • . -- . . - The items listed need clarification, modification or change. All items have to be 1.KINE NO. .4"33 satisfied before the plans will be in conformance with the cited codes and -.. 1IaOSURFS: . regulations. Per Sec. 303 (c), 1982 Uniform Building Code, the approval of the plans does - •- . ,. _______________________________________________ not permit the violation of any state, county - or city law. - - A. PLANS Please make all corrections on the original .' . - PRDJF ADDRESS: 29OI tracings and submit two new sets of prints, and -. any original plan sets that may have been ..• - -. . . returned to you by the jurisdiction, to: Esgil Corp., 9320 Chesapeake Drive, Suite 208, San Diego, -. . . .• . . . California 92123, (619) 560-1468. Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been PLAN (RRE(ION SHEET returned to you by the jurisdiction, to: . ,• :. SINQE MW DUPLEX Th1JNGS The jurisdiction's building department. - - Date plans received by jurisdiction: . . .,, i.,., _... To facilitate rechecking, please identify, - - next to each listed item, the sheet of the - 4 • - plans upon which each correction has been made - -• * Date plans received by Esgil Corporation: and return this check sheet with the revised plans . -..--. - • On the title sheet, indicate on plans the .. . Date initial plan check completed: • name of the legal owner and name of person — 6.5 By Li responsible for the preparation of the plans -- .• - -. - -- 44 5. ,. •; 'S Plans, specifications and calculations shall be signed by a California state licensed - . engineer or architect. (California Business •. and Professions Code). Specify on the title sheet of the plans the gross floor area of each element of this ?, project including dwelling, garage, carport, '.. .patio, deck nd balcony. Provide a statement on the title sheet of the plans that this project shall comply with ., the editions of the codes as adopted by the jurisdiction and listed on the attached supplement sheet. Submit fully dimensioned plot plan drawn to - scale showing location, size, and use of all - . existing and proposed structures on the lot. , Identify property lines and show lot dimensions - and all easements. Show location of all cut or • fill slopes and approximate finish floor . . . elevations for all, structures and show elevations at all lot corners. Section 302 (a) .7. ', Indicate distance from center-line of street or alley to property line and distance from property -lines to proposed building. Section 302 (a) 7. B. FIRE PROTECTION Walls closer than 3 feet to property lines •. shall be one-hour rated construction, have no openings, and shall have 30 inch parapets when .. the building floor area exceeds 1,000 square feet on any floor. (Table 5-A, Section 1709 •• • (a)).; )I. Projections, including eaves, my not extend more than 12 inches into the 3 foot setback from the property line. Eaves over '. required windows shall be not less than 30 S • inchesfrom the side-and rear property lines. '•' Section 1710 and Section 504 (a) and (b). S. .5 , ,f. .,.., -.5. Projections, including eaves, shall be one-hour fire-resistive construction, heavy timber or of non-combustible material if they project into the 3' setback area from the property line. Section 1710. Show location of permanently wired smoke detectors. Section 1210. /"/ D,i •4J .r.sic 6,iisr,,.j4 /QQj 14. A smoke detector shall be installed in the basement of dwelling units having a stairway which opens from the basement into the dwelling. Such detector shall be connected to a sounding device or other detector to provide an alarm which will be audible in the sleeping area. Section 1210. C. R(XII SIZES. u(r. VENTILATION AND GLAZING Habitable rooms, other than kitchens, shall contain at least 70 square feet of floor area. Section 1207. (b). Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1205 (a). Appears to be deficient in Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms, laundry rooms and similar rooms, minimum is 1.5 sq. ft. (Section 1205 (a) At least 1/2 of the common wall must be open and have an opening not less than 25 sq. ft. if light and ventilation is being supplied from an adjacent room. Section 1205 (a). ,.t4. Required windows shall not open into a roofed porch unless the ceiling is at least 7 feet and the longer side is at least 65% open. Section 1205 (a). - X. The loft you show does not comply as a mezzanine floor and is, by Uniform Building Code definition, a story. D. WITS. StAIRWAYS, AND RAILINGS Floors above the second story shall have - - - not less than 2 exits. Section 3303 (a). 1. Required exit doorways shall be not less than 36" in width and not less than 618" in height, and shall be capable of opening at least 90 degrees. Section 3304 (e). Provide 36" high protective railing for porches, balconies, and open sides of landings. Maximum opening between railings shall be less than 6". Section 1711. Show how guardrail connection details are - adequate to support 20 pounds per lineal foot at a right angle to the top rail. Table 23-B. Provide stairway and landing details. Section 3306 (b) & (c). Maximum rise 8" and minimum run is 9". - - Minimum headroom is 61 6". Minimum width is 30". - All handrails shall satisfy the • following: a. Provide handrail for stairways with 4 or more risers. -. - Handrail shall be 30" to 34" above the nosing of treads. The hand grip portion of handrail shall be not less than 1 1/4" nor more -. than 2" in cross-sectional dimension. Section 3306 (j), (see attached). - - Provide mechanical ventilation capable of providing five air changes per hour in - bathrooms, water closet compartments, laundry -. - rooms and similar rooms if required windows are not provided. Section 1205 (a). No habitable room, other than a kitchen, shall be less than V01' in any dimension. Section 1207 (c). - Show that ceiling height for habitable rooms is a minimum of 7'6". Section 1207 (a). Show ceiling height for laundry rooms, -,, hallways, corridors, and bathrooms is a minimum -. of 7'0". Section 1207 (a). ' () Provide 30" clear width for water closet compartments and 24" clearance in front of water closet. Section 511 (a). Specify safety glazing for glazing in -. hazardous locations such as glass doors, glazing adjacent to such doors and glazing adjacent to walking surfaces. Section 5406. -S . . . 26. Glazing in shower and tub enclosures shall e tempered, laminated or approved plastic - - . (including windows within 5 feet of tub or - shower floor). Section 5406 (d).. 1. Sleeping rooms shall have a window or exterior door for emergency exit. Sill height -shall not exceed 44" above the floor. The - -. - window must have an openable area of at least 5.7 square feet with the minimum openable width '.- 20" and the minimum openable height 24". Section 1204. A mezzanine is an intermediate floor and may not have a floor area exceeding 33 1/3 . :~ percent of the total floor area in the room below, and the mezzanine floor must have a clear height of 7 feet, above and below and -: must have the long side open to the room below except for posts and protective walls or railings notexceeding 42" in height. Section - -1716. -: • - -.;;-'.-- - ....-.'.....- ••. •-.v'12'-g?'' '-t; -: --1- :-- ,•,- •-- --~ .. .. '-.1 •• - L - )4'. Every stairway landing shall have a dimension, measured in the direction of travel, at least equal to the stairway width. Section 3306 (g) A door may open over a stairway landing . provided the door, in any position, does not reduce the clear area of the landing in the I ?direction of stairway travel, to less than one- half 'the required width of the stairway. Section 3306 (g). A door may open inward at the top step of a stairway provided the top step is not more - than7 1/2t* lower than the floor level. Section 3304 (h) Pro'ide details of vinding stairway. V,- a. Minim, 'tread is 6 inches at any point and minimum 9 inches at a point 12 *,f inches from the side of the stairway. b., Maximum rise is 9 inches. ' c. Minimum width is 30 inches. Section 3306 (d). - - 71 Provide spiral stairway details Minimum run is 7 1/2 inches at a point '. from where the tread is the narrowest. - Maximum rise is 9 1/2 inches. : Minimum headroom is 6 feet 6 inches .:. Section 3306 (f). Spiral stairways may not be used for . required exits when the area served is greater than 400 sq. it. Section 3306 (f). 4. Spiral stairways must have a clear walking space of 26 inches between the column and "•'f - handrail. Section 3306 (f). _:'t -- •-' .• , - -• , t ,'. . - : 1. :•:-. Provide I.C.B.0. Research Report and Number for metal stairway, or submit plans and calculations and approved fabricator registered with thd Building Department or note that the stairway fabrication shall be done under special inspection per the approved fabrication plans. Section 306 (a) 4B and Section 306 (f). In buildings over 2 stories in height, provide 3/4 hour fire-rated assemblies for all openings in the exterior wall below or within 10 feet horizontally of an exterior stairway. An exit balcony with 2 separated stairways is exempt. Section 3306 (1). 45. Exterior stairways shall not project into the 3 foot setback from the property lines. Section 3306 (n). The walls and soffits of the enclosed usable space under interior stairs shall be protected on the enclosed side as required for one-hour fire-resistive construction. Section 3306 (m). 07 ç cJAr', K. ROOFING ,'. Specify roof pitch. Roof pitch is not adequate for roof type specified. Specify minimum pitch of 4. Specify roof material and application. - -, - Specify I.C.B.0 or U.L. approval number for roof materials not covered in U.B.C., e.g., tile, etc. Specify that wood shakes are pressure treated Class C (when required by Jurisdiction - - Ordinance). Provide I.C.B.0. number. Specify that the roof system shall be fire retardant complying with Section 3203 (e). - .. I ,YS. Specify roof slope for drainage or design to support accumulated water. Section 3207 * (a). 1/4" per ft. mm . pitch per Section 2511 (d)6. Show roof drains and overflows. Section 1207. - Is Provide skylight details to show compliance with Sections 3401 and 5207 or. provide I.C.B.0. approval number (4' mm. betweenplastic skylights).0, Show attic ventilation. Minimum vent area is 1/150,of attic area or 1/300 of attic area :if at least 50% of the required vent is at least 3 feet above ceiling joists. Section 3205 (c). F.MASRY' ,. ii Provide fireplace construction details or note construction to be per attached fireplace standard drawing. Section 3707. ,2. Show 'eneersupport and connections comply , with Sction 3002; 4, 5, 6, and Section 2515 - (a).regarding ties and #9 wire in horizontal • joints or note construction to be per attached sheets 30-1 or 30-2. s... Show height and construction details of , all masonry walls. Chapter 24. >6'. Note that cleanout openings shall be provided at the bottom of all cells to be grout filled over 4' in a single pour. Cleanout V shall be sealed before grouting, after •• inspection. Section 2415. Show floor and roof connections to masonry walls. Connection shall resist 200 pounds per lineal foot or the actual design load, whichever is greater. Section 2310. ,. Show how masonry house walls retaining earth are to be waterproofed. Provide detail. V ': +•- V V V - '- V V - Show a minimum 2" air space and flashing between planter and building walls. Section 2517 (e).V G. GARAGE AND CARPORTS Garage requires one-hour fire protection on the garage side of walls and ceiling common to the dwelling. Table 5-B, Section 503 (b). All elements supporting floor above garage "including walls supporting floor joists, to have one-hour fire-resistive protection on the garage side. Section 503. Beams and posts, not within the wall or ceiling construction, must comply with UBC, Table 43-A, or be minimum 6" wide by 10" depth beam and minimum 8" by 8" post. Show 1 3/8" solid core self-closing door for openings between garage and dwelling. Section 503 (d). ,fr7' Garages are not permitted to open into a V ' room used for sleeping purposes. Section 1104. Openings between carport and residence require self-closing doors and stationary windows. Section 1214. Show garage framing section, size of header over garage opening, lateral cross bracing at plate line, method of bracing garage V front, and holddowns when required. Chapter 23. NOTE: Minimum plywood diaphragm ratio is 3 1/2 to 1. Table 25-I. Doors may open into the garage only if the floor or landing in the garage is not more than. 1/2" lower than theVdoor threshold. Provide 18" raised platforms for any FAU, /water heater, or any other device in the garage V which may generate a flame or spark. - OEM AR, .t. - : 0 . H. FOUNDATION RITS Show height of all foundation walls. - .- - chapter 23. Note on plans that "A soils engineer shall evaluate any unanticipated uncompacted fill or Show height of retained earth on all expansive soil or other soil problems disclosed foundation walls. Chapter 23. during construction". Section 306 (a) 12. - 73 Submit soils classification determination 0 Show distance of foundation to edge of cut fill 4 ,-. or slopes and show steepness and heights -by a licensed engineer or architect based on of cuts and fills. chapter 29. observation,, tests, borings, or excavations, and containing comments on the degree of Note on plans that wood shall be 6" expansiveness, compressibility and bearing minimum above finish grade. Section 2516 (c) value. The report shall include foundation 7. 'recommendations. Section 2905. Note (j) Note on plans that surface water will on the plan the soils classification, drain away from building and show drainage whether or not the soil is expansive, and note pattern and key elevations. Section 2905 (f). the allowable bearing value. Section 2905. Dimension foundation per U.B.C. Table - 75. The foundation plan does not comply with 29A: - the soils report recommendation for this Floors project. Please review the report and modify Supported* Stemwall Width Depth - , design,- notes and details as required. 1 6" 12" 12" • 2 8" 15" 18" 76. Provide notes on the foundation plan 3 10" 18" 24" listing the soils report recommendations for .1 foundations slab and building pad preparation. *Foundations may support a roof in addition to . - the floors, where only a roof is supported, use 77. Note on the foundation plan that "Prior to foundation for one floor. . the Contractor requesting a Building Department Foundation Inspection, the soils engineer shall $~. Show foundation sills to be pressure advise the building official in writing that: treated, or equal. Section 2517 (c) 3. 1. the building pad was prepared in ,. Show foundation bolt size and spacing. 0 accordance with the soils report; Section 2907 (e). - - - 2. the utility trenches have been X. Specify size, I.C.B.0. number and properly backfilled and compacted, manufacturer of power driven pins. Show edge • . • and; • - and end distance and spacing. Section 306 ' (f). • 3. the foundation excavations, formings and reinforcements, comply with the - () Show size, imbOdment and location of hold - . soils report and approved plan". down anchors on foundation plan. Section 2312 - •• 78. Provide spread footings for concentrated -.-:- :.-- - • oads designed for 1,000 PSF soil bearing or -' , per bearing value as determined by an engineer - - : - - . or architect. Chapter 29. • • . . . - . - .-• .• . • - - - . . . 0 -* • • - :- V 21 \ , jVV V. V. VV VV&tVV V Note on plan that hold down anchors must be tied in place prior to foundation inspection. Section 2312 (f). V.' Show adequate footings under all bearing walls and shear walls. Section 2311 (e). VT 5r,'4i. Show stepped footings for slopes steeper than 1:10. Section 2907 (c). Show minimum 18" clearance from grade to bottom of floor joists and minimum 12" clearance to bottom of girders. Section 2516 ( - * . Show pier size, spacing and depth into V V undisturbed soil. Table 29-A. ,.4 OAJ Show minimum underfloor access of 18" X 24". Section 2516 (c). - V •. V • Show minimum underfloor ventilation equal to 1 sq. ft. for each 150 sq. ft. of under floor area. Openings shall be as close to corners as practicable and shall provide cross or at least two approximately opposite sides. Section 2516 (c). Specify that posts embedded in concrete V . shall be pressure treated per UBC Std. No. 25- -12.1-Section 2516 (c). .IFRAMING V V Show wall bracing. Every exterior wood stud wall and main cross partition shall be i braced at each end at least every 25 feet of -- length with 1X4 diagOnal let-in braces or V . equivalent. Section 2517 (g) 3. Z..ar ,3 - V • Note cross bridging or blocking. Floor joists and rafters 12" or more in depth shall V be supported laterally by bridging at intervals not exceeding 8 feet, unless both edges are held in line. Sec. 2506 (g). V VV • 'V V • V ,94'. Show blocking at ends and at supports of floor joists, and for rafters at exterior walls. Section 2517 (d) 3. 0. Show solid blocking at ridge line and at exterior walls on trussed roofs. Section 2506 (g). Show double joists. Floor joists shall be doubled under bearing partitions running parallel with the joists. Section 2517 (d) 5. (02 Show rafter ties. Rafter ties shall be spaced not more than 4 feet on center where rafters and ceiling joists are not parrallel. Section 2517 (h). 0.i1' AJ/ //-rV/V? Show rafter purlin braces to be not less than 45 degrees to the horizontal. Section 2517 (h). Show 1/2" minimum clearance between top plate of interior partitions and bottom chord of trusses. (To ensure loading will be as designed). Show double top plate with minimum 48" lap splice. Section 2517 (g). Show nailing will be in compliance with Table 25-Q. V V )4. Show or note fire stops at the following V locations per Section 2516 (f): in concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels and at 10- foot intervals along the length of the wall. at all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings; - in concealed spaces between stair • 1 stringers at the top and bottom of the run and between studs along and in line with the run of stairs if the walls under the •• stairs are unfinished; and - in openings around vents, pipes, ducts, - 1.- . chimneys, fireplaces and similar openings which afford a passage for fire at ceiling • and floor levels, with noncombustible materials. Show stud size and spacing. Maximum allowable studheights; Bearing wall: 2X4 and 2X6 max.-10'; Non-bearing: 2X4 max. 14', 2X6 . -. max. 20'. Table 25-R-3. Note an A.I.T.C. Certificate of Compliance for glued laminated wood members shall be given to the Building Inspector prior to erection. Section 306 (f). .. •: Détailallpost to beam and post to - •. • •.' footing connections: Section 2516 (c). C!) Detail shear transfer connection including roof and floor diaphragms to shear . walls. Section 2513. Specify nail size and spacing for all shear walls, floorand roof diaphragms. - .- Indicate required blocking. Maintain maximum '• • . - diaphragm dimension ratios. (Tables 25 I, J, K) and Section 4713 (d). -. 5' Show 3174" or 2"X6" studs in first story of three storybuilding. Table 25-R-3. Provide truss details and truss. - calculations for this project. Provide' roof framing plan and floor • t g_. framing plan. Section 302 (a),7. • - - .., . .•• ....................• : Provide framing sections through________ Section 302 (a) 7. Specify all header sizes for opening over 4' wide. Section 2517 (g) 5. 1). Provide calculations for Section 320 (a) 7. 3$. Show on the plans all structural requirements developed in the structural calculations. In areas subject to water splash and ii exterior locations, wood columns and posts shall be supported by piers projecting at least 2" above the finished grade and shall bear on a - metal base plate or treated wood unless the columns or posts are foundation grade redwood or cedar. Section 2516 (c) 4. Show location of attic access with minimum size 22" X 3011. Section 3205. 34. Show draft separation for attic areas between units in a duplex. Section 2516 (f). )/3. Show draft separation for space between dropped ceilings and floor above in excess of 1,000 sq. ft. Section 2516 (f). Specify plywood grade and panel indentification index. Table 25-N. When roof pitch is less than 3:12, design ridge as a beam. Section 2517 (h). If foundation cripple wall studs are less than 14" framing shall be solid blocking. Section 2517-(g) 4. -. Furnace shall not be installed under any stairway. Section 704 UMC Furnace shall not be installed in any bedroom, bathroom or in a closet or confined space with access only through such room, unless specified as direct vent appliance, enclosed furnace or electric heating appliance. Section 704 UMC. Show I.C.B.0. approval for prefab fireplace. Show access to the attic or underfloor furnace to be minimum 30 inches by 30 inches. Sec. 708 & 709 UMC. Note that passageway to the attic furnace shall be unobstructed and have continuous solid flooring not less than 24 inches wide. Section 708 UMC. Show permanent electrical outlet and lighting fixture controlled by a switch for the attic furnace. Section 708 UMC. Show details to comply with Section 709 for furnace under the floor, or Section 710 for roof or outside furnace. Note on plan, gas vents and non- combustible piping passing through three floors or less shall be effectively draft stopped at each floor or ceiling. • UBC Section 1706 (a) 6. F. K. ELICAL (NATIONAL KL'.rRICAL CODE) All wiring shall comply with the National Electrical Code. Ze . Note on the plan the amperage of ctrical service. Show location of all electrical receptacles. yif if 4. ?- 127. Cripple wall studs exceeding 4 feet in. F ' ... height shall be 3 inch by 4 inch or 2 inches by 6 inches when supporting 2 stories. Section 2517 (g) 4. Show plywood sheathing over exposed eaves, or other weather exposed areas, is exterior grade. Section 2516 (g) 3. )?4.' Show a weep screed at the foundation .. •' plate line on all exterior stud walls to be stuccoed. Section 4706 (e). - Show corridor width to be minimum 36". . ' -Section 3305 Specify truss layout for 30" X 30" attic - access. -. - Ridges, hips, and valleys. shall be at least one size larger than supported rafters. Section 2517 (h) 3. lfi.- Provide metal straps across ridge beam and rafters. . 'J.. MANICAL - All heating, ventilating, and cooling systems - and appliances shall comply with the Uniform - Mechanical Code. Shw the size, location and type of all heating-and cooling appliances or systems. 135. Show method of providing combustion air to furnace, per Chapter 6, UMC. Every dwelling unit shall b provided -. with heating facilities capable of maintaining .• . aroom temperature of 70 derees F: at 3 feet above the floor in all habitable rooms. Show basis for compliance. UBC Sec. 1211. . a + . . - - 137. Show minimum 30" deep unobstructed - •• workinj space in front of furnace. - * - 138. Note on plans, clearances to be per manufacturers listing. Section 704 UMC. -F- - -14 4 . \•......• V •, - L V V - V Electrical receptacle locations and/or )1. Shower stall shall accommodate a 30" - V •V V: spacing is not adequate in 2AJ V circle and have a minimum floor area of 900 sq. V V in. UPC 909 (d). V r r V N NOISE INSULATION (DUPLEXES) At least one receptacle shall be Show details of duplex common (party) V V 'and walls floor/ceiling assemblies to achieve a V installed-outdoors, in basements and attached Sound Transmission Class (STC) rating in walls - garages, other than laundry outlets. Art. V of 50 decibles and on Impact Insulation Class VV VI V 21025 (b). •VV V V (IIC) rating on floor/ceiling of 50 decibles. V V V V Title 25. V - ]f •Show minimum dwelling lighting (NEC Art. - - '2l0-26 (a) and-GFI's in garage, baths and V V V V Show how penetrations of assemblies for V V outdoors. NEC Art. 210-8 (a). VV V V piping, electrical devices, recessed cabinets, V• V V V' (j) Note "UM" 'ground to be (NEC). provided bathtubs, soffits, or heating, ventilating or V exhaust ducts shall be sealed, lines, or V ' Art. 250-81. V V insulated to maintain required sound V V transmission rating. Title 25. V V L. PLUMBING (UNIFORM PU4BING CODE) .- : - V Provide insulation in walls and ceiling V - All plumbing shall comply with the Uniform to achieve SIC of 50 between garage and living 5 Plumbing Code.--• V V area if garage use is not controlled by V * V V •V Show water heater size, type and location resident Title 25. V V VVV on plans. . V 164.ENERGY CONSERVATION: PLEASE READ 154. Show method of providing combustion air V New state mandated regulations (Calif. Admin. V V . • to fuel burning water heater.,Section 1307. Code) became effective June 16, 1983 and If vented door, vents, must be at top and • require that the design satisfy one of the V V • bottom. : alternative energy packages A, B, C, D, E, 1, V V V Fuel combustion heater be water shall not 2, 3, 4, 5, 6 or AB 163. The law also requires ' V that many mandatory conservation items be -,installed in bath or bdroom or in a closet V satisfied. , opning into bath or bedroom. Section 1309. V V .. Provide adequate barrier to protect water Zter Show on the title sheet of the plans, the alternative energy package that was selected from vehicle damage. Section 1310. / V i.e., A, B, C, D, E, 1, 2, 3, 4, 5, 6 or AB 163 - V Show T and P Valve on water heater and to show compliance, and provide calculations and other data, appropriate to that selected V . show route of discharge line to exterior package. :1 Section 1007 (e). - . •* V - - Provide dryervent to outside. UMC V ; V V . ).~. The responsible designer should sign a statement, on the plan title sheet, "The design Section 1903. • submitted substantially conforms to the Energy - . Note on the plan that hose bibbs and lawn Regulations for Residential Buildings." V sprinkler systems shall have approved backf low V - prevention devices. Section 1003. V - Vs . • • VV V V • V S V V• -. • V • V V S - S S . 17 DviRM S S Show the "R" value for the walls, floors, c&yi.ss.z S.F.D. & DUPLEX SUPPLEMENT ceiling and related areas. co Note on the plans, all work shall comply . 167; Provide a schedule on the plans showing with the 1982 UBC, 1979 UPC, 1984 NEC, 1976 -: • - thermal mass requirement. Specify rooms, materials, required area and thickness of materials. - ,S]#' Lateral load design should be based on Seismic Zone 4. 168. Show double glazing as per Energy Design, - ,--. on Gl.zing Schedule. • Energy conservation design should be for S - . Zone 7. See attached energy packages. - (T) Show total glazing areas on the plans. All buildings, except M Occupancies ,-170. Shos on the plan how shading requirements require a fire retardant roof. Note on plan - will be satisfied., that roof is to be fire retardant per Sec. - 3203 (e). - 171. Show on the plans details of required - movable insulation. Show how the curtains or Show location of electrical panel; cannot device will be sealed and gasketed to provide a be in a concealed location. dead air space. P & T. drainlines must drain to a floor The plans are not in compliance with the sink, floor drain or to the exterior, they - '.- energy conservation compliance package selected cannot discharge into an upright sink. or design calculations provided. Show onplans S - S • - conformajce as follows: j4. Townhouses (postage stamp lots) must have /J 6AJ? i "walls and utilities in accordance with attached City Policy 80-13. • ' Lia :5/&J / S Floor drains must have auto-prime (city S _________________________________________ policy)- G ) Specify on the building plans all of the 38(. Note exhaust fans cannot be ductless type 5S_ . mandatory energy conservation requirements as (city policy). listed on the enclosure titled, "Mandatory - Energy Conservation Requirements". New residential units must be pre-plumbed • - - - for future solar water heating. Show two roof - -. Show the size, t½e and location of the jacks where the water heater is in the one - - 'space heating (or cooling) system and provide story garage and directly below the most south - energy calculations if the output BTU/Hr. facing roof (City Ordinance No. 8093). exceeds 45,000 BTU/Hr. output. - Two 314" copper pipes must be installed -.. '/heaters pools and spas with fossil fuel from the most convenient future solar panel - .. heaters require pool covers as well *as other • location when the water heater is not in a one - - energy saving devices such as time.clocks, etc. story garage and is not directly below the most - • - . - •- T20-1406. south facing roof. (City Ordinance No. 8093). :. . - •k • - - S - - S - - • : . •'•S__. S - ' S . - - . - - - - • frSS •S_ - - - -- :._•- ••••- - All piping for present or futur& solar water heating must be insulated when in areas that are not heated or cooled by mechanical means (city policy). Incorporate the waterproofing details, on the attached Policy 80-8, where interior living .space occurs below grade at the masonry wall(s). Show on the Title Sheet of the plans, the information requird by the attached Developmental Services Sheet .. _•f - -.-• The City of Carlsbad has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform - the plan check for your project If you hive any questions, please contact yI.v il10 i' - at EsgilCorporation. If you have any questions regarding permit procedures, please 'cntact Carter Darnell at the City of Carlsbad, 1200 Elm Avenue, telepl-ione 619/438-5525. Thank you. . , Enclosures: 1. . - • 3. • - -- . - --.•. flj • : 1? -' •"_4'_ 1_,-, -4 -c,2s O ,14,11 X AJ AJb4 S7J, Al /f4 /"e IL (7t4/3 /3 et 0j /-4Oc#? .4J " °'- ('cit - T77- - - -r_,•_' ,' . - a "---:• --, • '4 ,; 44 4 - -, - ------ ,- - V * - - -. - 4r •(-* I - - Date i Jurisdiction - Prepared byt 0 Bldg. Dept. 4I/ VALUATION AND PLAN -CHECK _FEE C3 Esgil - PLAN CHECK NO - -BUILDING ADDRS - Y7i /-/c/,4,qA.,V APPLICANT/CONTACT PHONE NO 4/ 3 3-3 ~5 - BUILDING'OCCUPANCY /-/ DESIGNER PHONE___________ TYPE OF CONSTRUCTION VI', CONTRACTOR PHONE____________ BUILDING PORTION BUILDING AREA VALUATION MULTIPLIER VALUE ___________ _________ _______ • tV Air Conditionine Commercial _•@ _____________________ Residential Res''.-or Comm. Fire Sprinklers • V Total -Value V - - - - F:ee Adjusted To •Reflect 0 Energy Regulations (Fee x 1.1) V 0 Handicapped Regulations (Fee x 1.065) 4 Building Permit Fee $ $ , Plan Check Fee $ _$ - V 4.: •V •' - V V V V •V • :-.: - - - - I-. •••••• •V VVt t1EN TS: _• V : VV V. • V : .• . -- ••V:_4 • - V V•V •• ; • - V V V •, - V - - V V' 4 -- •- V•• 8/4/82