Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2701 LOKER AVE W; 250; CB141523; Permit
City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 09-12-2014 Commercial/Industrial Permit Permit No: CB141523 Building Inspection Request Line (760) 602-2725 Job Address: 2701 LOKER AV WEST CBADSt: 250 Permit Type: TI Sub Type: IN DUST Status: ISSUED Parcel No: 2090812200 Lot #: 0 Applied: 06/27/2014 Valuation: $261,325.00 Construction Type: lB Entered By: LSM Occupancy Group: Reference # Plan Approved: 09/12/2014 Issued: 09/12/2014 Inspect Area Plan Check #: Project Title: PERSONAL STRENGTHS- 7,040 SF TI OFFICE TO OFFICE TO INCLUDE NEW PARTITIONS, CASEWORK! CEILINGS/RELOCATE MECH/NEW DUCTS Applicant: Owner: ROB NELSON GATEWAY COLORADO PROPERTIES INC STE 210A . C/O TTNE PROPERTY TAX - DEPT 207 70516THST PO BOX 4900 SAN DIEGO CA 92101 SCOTTSDALE AZ 85261 858-414-2966 Building Permit $1,330.66 Meter Size Add'I Building Permit Fee $0.00 Addi Red. Water Con. Fee, $0.00 Plan Check $931.46 Meter Fee $0.00 AddI Building Permit Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $54.88 PFF (3105540) $0.00 Park Fee $0.00 PFF (4305540) $0.00 LFM Fee $0.00 License Tax (3104193) $0.00 Bridge Fee $0.00 License Tax (4304193) $0.00 BTD #2 Fee $0.00 Traffic Impact Fee (3105541) $0.00 BTD #3 Fee $0.00 Traffic Impact Fee (4305541) $0.00 Renewal Fee $0.00 PLUMBING TOTAL $47.00 Add'l Renewal Fee $0.00 ELECTRICAL TOTAL $137.00 Other Building Fee $0.00 MECHANICAL TOTAL $42.45 Pot. Water Con. Fee $0.00 Master Drainage Fee $0.00 Meter Size Sewer Fee $0.00 AddI Pot. Water Con. Fee $0.00 Redev Parking Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 Green Bldg Stands (5B1473) Fee $8.00 HMP Fee ?? Fire Expedidted Plan Review $0.00 Green Bldg Standards Plan Chk TOTAL PERMIT FEES $2,551.45 Total Fees: $2,551.45 Total Payments To Date: $2,551.45 Balance Due: $0.00 FINAL APPROVAL Inspector: ' Date: (LI1 Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you prbtest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Casbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any ITHE FOLLOWING APPROVALS REQUIRED PRIOR TOPERMIT ISSUANCE: DPLANNING DENGINEERING [--]BUILDING DFIRE DHEALTH DHAZMAT!APCD I .. Building Permit Application Plan Check No. 41-14k CPq-i 6-3. 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value L ••3• 5- \/ C I TV 0 F . Ph: 760-602-2719 Fax: 760-602-8558 CARLSBAD email: buiIdingcarIsbadca.gov Plan Ck. Deposit Q . I Date (./-7 ) I L IswPPP I www.carisbadca.qov JOB ADDRESS . . 2701 Loker Ave. West SUITE#/SPACE#/UNIT# 250 APN - 209 - 081 - 22 T 00 CT/PROJECT if LOT if PHASE U U BATHROOMS TENANT BUSINESS NAME . CONSTR. TYPE 0CC GROUP S 1 #13FUNITS J #BEDROOMS I Personal Strengths Publishin B DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) Tenant Improvement of an existing 7040 Sq Ft tenant office space. . • EXISTING USE fJFfI PROPOSEISE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE AIR CONDITIONING FIRE SPRINKLERS Business Business N/A . N/A N/A YES[] NO YESNO .YESNO APPLICANT NAME. . ..- .rsonaI Strengths Publis , Inc. PROPERTY OWNER NAME - Gateway Colorado Properties, Inc. 0DRESS - 2701 Lo Ave W , Suite 250 ADDRESS - , 5935 Cornerstone Ct. W. CITY - . ZIP Carlsbad CA 92010 CITY STATE • - ZIP - San Dieqo CA * 92121 PHONE - - 800. . 347 .' FAX PHONE 858.622.9551 FAX . - EMAIL . - ". EMAIL .-kevMrestrenqthseonr Sean.McCormack(transwestem.com DESIGN PROFESSIONAL • Rob Nelson! Moniker Group CONTRACTOR BUS. NAME ---- -------- Lfij c. BORESS • - - • 705 16th St. Suite 210A_ ADDRESS - 7_0'-11R Chao WHO QJ. CITY . - STATE ZIP San Dieqo • . CA 92101 CITY STAT.E ZIP Raipi,,ng • I9 PHONE - • 858.414.2966 FAX . . PHONE/ I 76 ?Z- FA/" -' ('i) 79' /2J EMAIL . rob(robnelsonad.com . EMAIL f) (a (t—i - - STATE LIC. U C-32892 •i, STATE LIC.0 16,9t . C CITY BUS. LICe (4,f toec. iii.a.i.. ousiness anti rroiessions c.oae: wny city or uounty wnicn requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance; also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions bf the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a -, civil oenaltv of not more than five hundred dollars 1650011. aII(.i 1M P ' N zi' 1r.TLI__.. Walkers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. • I have and will maintain workers compensation as re r ed by Section 370001 the Labor Code for the performance of the work for which this permit is issued My workers compensahon in urance amer and policy rare:Insurance S11 A4 POIIC NOTgOz 7f/ • EpfratonDaI7/O(//_c T i section need not be completed if the permit is for one hundred dollars ($100) or less. Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of Ca !fomia. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In addition to the cost of compensation, dam ges as provided for in Section 3706 of the Labor code, Interest and attorney's fees. Lj?iijj/7- DAGEN K, CONTRACTOR SIGNNT RE'~.T CAT> 97/2//ce OW N ER-B U IILC~ER'•. $ p1IJ.uI6LL1J thereby affirm that lam exempt from Contractor's License Law for the following reason: ' [] I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) * 0 I, as owner of the property, am exclusively contracting with licensed conk-actors to construct the project (Sec 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and conk-acts for such projects with contractor(s) licensed pursuant to the Conk-actor's License Law) • -' • ' • - [] I am exempt under Section • Business and Professions Code for this reason: . 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Dyes ONO - . 2. I (have! have not) signed an aplication for a building permit for the proposed work. ' . • . I have cdnlracted with the following person (firm) to provide the proposed construction (include name address! phone! contractors' license number): • • , - I plan to provide portions of the work, bull have hired the following person to coordinate, supervise and provide the major work (include name! address phone contractors' license number): - 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name! address phone! type of work),. .PROPERTY OWNER SIGNATURE AGENT DATE • 4- • ', * . .t .,.. .•', .lam 0100 1 130.. .Uwun Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? ,Yes No , Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? L Yes No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? ' Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address - -, '•.••- I cmrtiithat I have read theapptication and state thatthe above information Is correct and that the information on the plans Is accurate. I agree to comptywith all Cityonfinancesand State laws relating to bulldlngocnsfluctlon. - I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY INCONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSI-IA An OSHA permit is required for excavations over 50' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provistuns of this Code shall expire by limitation and become nut and void itthe building or work authorized by such permit is not comrrrenzed within l8odaysfrom the date of such permitorif the bu r ork orized by such permit is suspended or abandoned at any tirm after the work is commenced fora period of 180 days (Section 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE - - . - - : DATE 4 ' 4 -- .. -- •-- - . '. ' - .- ., I 4 I I •-' - ' 1. ' E .1: , . . r- V ' STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. . Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. I . I gE OF OCCUPANCY (Co mmercial Projects .uwj Fax (760) 602-8560, Email buiIdina(casbadca.gOV or Mall the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. , - CO# (Office Use Only) CONTACT NAME - - -. OCCUPANT NAME - -. - - ADDRESS - , - BUILDING ADDRESS - - CITY, - - - STATE — ' . ZIP - CITY STATE ZIP -, : , - Carlsbad '. .- -. CA - - PHONE . ..-- FAX - - - EMAIL - - - - - , •-. OCCUPANT'S BUS. UC. No. - •_, - DELIVERY OPTIONS PICKUP: . CONTACT (Listed above) "OCCUPANT (Ustedabove) CONTRACTOR (On P. 1) - J - .- - - •' - -, • , - " ASSOCIATED CB # - - . . - ' MAIL TO: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) -. NO CHANGE IN USE / NO CONSTRUCTION "MAIL / FAX TO OTHER: - CHANGE OF USE/ NO CONSTRUCTION •• , . - S I •'• - .APPLICANTS SIGNATURE DATE - .. ..- .. '.- 1 • :- - ". . ' + - ' '" -,.'. • r 44 . .4_I ,' - - 'I • -' - ' 4_4+ - -', . 4. .. '_• , ,. .- I 4 4 4 4 - ••_.t ". - 4 4 \ •, .. .,. '_. 4 4-, ,- .4 - '•-(• 4 - ., I S - - - - • • .- - I. ,."- •j._' - - ' . I - -- 44 , ' L .1 . '-. ' -. - .•' . - . -. . •' .- . '- -'. : .---• -. , . . - . .I ' • , .. - • - -• . . -. - .' , , ,. . -. £ -- If. - .__. .:- - . • - - - 4 1 , •_,, - 4. _ .4 , . '.- - . - ,. - - - -, • . .4 1 - - ' 1_v f - ' - . , '. , _.s. •. * . - • 4 ' -4.,-. - i - t •. . - - - . - . - . -. -' -4 - I - I -. ,- . • - -' • '•1 Permit# CB141523 Type TI INDUST PERSONAL STRENGTHS 7,040 SF . ,. . .• . : TI OFFICE TO OFFICE TO INCLUDE NEW Date Inspection Item Inspector : Act Comments: 11/14/2014 89 Final Combo : . . : i I. RI COF .. . . . . . 11/14/2014 89 Final Combo MC Fl 10/24/201485 T-Bar : PY AP 10/14/2014 1.7 Interior Lath/Drywall . MC :. AP . WALLS . 10/07/2014 34 Rough Electric MC AP WALLS ONLY 10/03/2014 14 Frame/Steel/Bolting/Weldin MC AP 10/03/2014 34 Rough Electric MC NR Monday, November 17, 2014 •. .: " : Page 1 of 1 CB141523 2701 LOKERAV WEST 250 PERSONAL STRENGTHS- 7,040 SF TI OFFICE TO OFFICE TO INCLUDE NEW PARTITIONS CASEWORK/ CEILINGS/RELOCATE MECH/NEW DUCTS TI INDUST Lot#: ROB NELSON 'N ' S . CITY OF CARLSBAD INSPECTION RECORD 1I INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB (I CALL BEFORFJ10rn FOR NEXT WORK DAY INSPECTION El FOR BUILDING INSPECTION CALL: 760-602-2725 4 OR GO TO: www.carlsbadca.goV/Bulldlflg AND CLICK ON 'Request Insoectioni I I ' I I, i "_ -- —I-. IF YES' IS CHECKED BE_OW THAT DIVISION'S APPROVAL IS REQUIRED PRIOR TO REQUESTING A FINAL BUILDING INSPECTION. IF YOU HAVE ANY QUESTIONS PLEASE CALL THE APPLICABLE DIVISIONS AT THE PHONE NUMBERS PROVIDED BELOW. AFTER ALL REQUIRED APPROVALS ARE SIGNED OFF— FAX TO 760-602-8560, EMAIL TO BLDG INS PECTIONSCARLSBADCA.GOV OR BRING IN A COPY OF THIS CARD TO: 1 635 FARADAY AVE.. CARLSBAD, CA 92008. BUILDING INSPECTORS CAN BE REACHED AT 760.602-2700 BETWEEN 7:30 AM — 8:00 AM THE DAY OF YOUR INSPECTION. PriorRequired Requesting Building Final It Checked YES ..iIr'z:I1r.iui CM&I lEngineering Inspections) 760-438-3891 Call before 2 pm l~ - a -- IN Type of Inspection Type of Inspection #11 FOUNDATION Date Inspector Date Inspector #31 0 ELECTRIC UNDERGROUND 0 UFER #12 REINFORCED STEEL #34 ROUGH ELECTRIC #66 MASONRY PRE GROUT #33 0 ELECTRIC SERVICE 0 TEMPORARY 0 GROUT 0 WALL DRAINS #35 PHOTO VOLTAIC #10 TILT PANELS #39 FINAL #11 POUR STRIPS #11 COLUMN FOOTINGS #41 UNDERGROUND DUCTS & PIPING #14 SUBFRAME 0 FLOOR 0 CEILING #44 0 DUCT& PLENUM 0 REF. PIPING #15 ROOF SHEATHING #43 HEAT-AIR COND. SYSTEMS #13 EXT. SHEAR PANELS #49 FINAL #16 INSULATION #18 EXTERIOR LATH #81 UNDERGROUND (11,12,21,31) #17 INTERIOR LATH & DRYWALL c/t4/I4. t4t #82 DRYWAU.,EXT LATH, GAS TES (17,18,23) #51,. POOL EXCA/STEEL/BOND/FENCE #83 ROOFSHEAT1NG, EXT SHEAR (13,15) #55 PREPLASTER/F1NAL #84_ FRAME ROUGH COMBO (14,34,* 10 /07114 1*k CiL4tj, #19 FINAL #85 T-Bar (14,24,34,44) .. /Oflft.JI( #22 0 SEWER & BL/CO 0 PL/CO Date Inspector #89 FiNAL OCCUPANCY (19,29,39,49) JI;1 Date Inspector #21 UNDERGROUND DWASTEOWTR #24 TOP OUT OWASTE DWTR A/S UNDERGROUND VISUAL #27 TUB & SHOWER PAN A/S UNDERGROUND HYDRO #23 OGASTEST DGASPIPING A/S UNDERGROUND FLUSH #25 WATER HEATER A/S OVERHEAD VISUAL , , 1e/- (rW'- #28 SOLAR WATER A/S OVERHEAD HYDROSTATIC ,• ), 7'ft4 ' #29 FINAL A/S ANAL #600 PRE-CONSTRUCTION MEETING F/AROUGH.IN CIA F/A ANAL #603 FOLLOW UP INSPECTION FIXED EXTINGUISHING SYSTEM ROUGH-IN #605 NOTICETO CLEAN AXED EXTING SYSTEM HYDROSTATIC TEST #607 WRITTEN WARNING FIXED EXTINGUISHING SYSTEM ANAL #609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST #610 VERBAL WARNING MEDICAL GAS FINAL SEE BACK FOR SPECIAL NOTES Section 5416. Health and Safety Code, State of California (a) There shall be not less than one water closet for each 20 employees or fractional part thereof working at a construction job site. The water closet shall consist of a patented chemical type toilet. For the purpose of this section the term construction site shall mean the location on which actual construction of a building is in progress. A violation of this section shall constitute a misdemeanor. All construction or work for which a permit is required shall be subject to inspection and all such construction or work shall remain accessible and exposed for inspection purposes until approved by the inspector. Work shall not be done beyond the point indicated in each successive inspection without first obtaining the approval of the inspector. DATE ADDITIONAL NOTES EsGil Corporation In (Partnership with Government for Building Safety DATE: 9/11/14 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 14-1523 SET: III I APPLICANT JURIS. L PLAN REVIEWER U FILE PROJECT ADDRESS: 2701 Loker Ave West Suite 250 PROJECT NAME: Personal Strengths Publishing - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. El EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person REMARKS: Applicant to hand carry the plans directly to the City of Carlsbad and to remove the PME sheets from City set I and slip sheet into City Set Ill, this does not assure a permit will be issued the city may have other corrections. By: Doug Moody Enclosures: EsGil Corporation E GA fl EJ fi MB fi PC LOG 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576 EsGil Corporation - In (Partners/lip with government for Bui(Iing Safety DATE: 8/1/14 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 14-1523 SET: II ,lJ APPLICANT ¼URIS. PLAN REVIEWER FILE PROJECT ADDRESS: 2701 Loker Ave West Suite 250 PROJECT NAME: Personal Strengths Publishing - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. El The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. . The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Rob Nelson 7505 16 th Street #210A San Diego, CA 92101 EsGil Corporation staff did not advise the applicant that the plan check has been completed; EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Rob Nelson Telephone #: 858-414-2966 Date cntacted:'/I (b4j_) Email: rob@robnelsonad.com Fax #: 47 MaiIV Telephone Fax In Person REMARKS: By: Doug Moody (SA) Enclosures: EsGil Corporation El GA EJEJEMB ElPC 7/25/14 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 14-1523 8/1/14 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support and lateral bracing of the new operable partition. Include all calculations and finding on the plans. Please include the California license number, seal, date of license expiration and date * plans are signed. Business and Professions Code. The correction response provided for this correction reads as follows: "OPERABLE PARTITION" HAS BEEN VALUE ENGINEERED OMITTED FROM THE PROJECT. If the operable partition has been removed from the "SCOPE OF WORK", please clearly indicated on the first sheet of plans. 13. Show that the minimum strike edge distances are provided at the level area on the side to which a do6r (or a gate) swings, per Section 11 B-404.2.4: a). 218" at interior conditions for door 2601 and 2201. Door 2601 is still not showing the minimum 18" as required. Original correction is still applicable for Door 2601. . • City of Carlsbad 14-1523 8/1/14 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe, them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes U, No U The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody (SA) at Esgil Corporation. Thank you'. T. EsGil Corporation In Partnersfiip with Government for Bui&fing Safety DATE: 7/10/14 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 14-1523 SET: I U APPLICANT JURIS. U PLAN REVIEWER U FILE PROJECT ADDRESS: 2701 Loker Ave West Suite 250 PROJECT NAME: Personal Strengths Publishing - TI T1 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. LII The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Rob Nelson 7505 16 th Street #210A San Diego, CA 92101 E EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Rob Nelson Telephone #: 858-414-2966 Date contacted: <1 (by:yi) Email: rob@robnelsonad.com Fax #: LMaiI TeIeihone Fax In Person L(Y:)) LII REMARKS: By: Doug Moody Enclosures: EsGil Corporation GA E EJ E MB E PC 6/30/14 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad .14-1523 7/10/14 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 14-1523 JURISDICTION: City of Carlsbad OCCUPANCY: B USE: Office ACTUAL AREA: 7040sf ALLOWABLE FLOOR AREA: STORIES: 2 HEIGHT: SPRINKLERS?: Yes OCCUPANT LOAD: 94 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 6/27/14 DATE INITIAL PLAN REVIEW COMPLETED: 7/10/14 FOREWORD (PLEASE READ): DATE PLANS RECEIVED BY ESGIL CORPORATION: 6/30/14 PLAN REVIEWER: Doug Moody This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on, regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2013 CBC, which adopts the 2012 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad 14-1523 7/10/14 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. 2. Please provide a statement on the Title Sheet of the plans to show compliance with the current Codes. The following are the correct current Codes: The 2013 edition of the California Building Code (CBC) adopts the 2012 International Building Code (IBC) and the 2012 California Amendments. The 2013 edition of the California Electrical Code (CEC) adopts the 2011 National Electrical Code (NEC) and the 2012 California Amendments. The 2013 edition of the California Mechanical Code. (CMC) adopts the 2012 Uniform Mechanical Code (UMC) and the 2012 California Amendments. The 2013 edition of the California Plumbing Code (CPC) adopts the 2012 Uniform Plumbing Code (UPC) and the 2012 California Amendments. The 2010 edition of the California Energy Efficiency Standards, 3. Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support and lateral bracing of the new operable partition. Include all calculations and finding on the plans. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. 4. Provide a section view of all new interior partitions. Show: a) Method of attaching top and bottom plates to structure for all walls. (NOTE: remove detail 16 on sheet A7.0 or provide evidence the existing City of Carlsbad 14-1523 7/10/14 suspended ceiling was designed to provide lateral bracing for partitions and include the required details from the suspended ceiling manufacturer). b) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. Provide a note on the plans or on the finish schedule, stating, "Wall 6nd ceiling materials shall not exceed the flame spread classifications in IBC Table 803.9." Exit doors shall swing in the direction of exit travel when serving a room containing an occupant load of 50 or more persons (door 2402). Section 1008.12. Corridors shall have interior door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes for door 0101. Table 716.5. Doors shall be maintained self-closing or be automatic closing by action of a smoke detector per Section 909.5.2. Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top. Section 716.5.3.1. Please clarify the lighting plan and the reflected ceiling plan new lighting fixtures . are shown.inthe Lobby? Advisory Note : When alterations, structural repairs or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the following requirements, per Section 11 B-202.4: The area of specific alteration, repairor addition must comply as "new" construction. A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. The path of travel shall include the existing parking. Existing toilet and bathing facilities that serve the remodeled area must be shown to comply with all accessibility features. Show on the site plan the complying disabled accessible path of travel from the disabled accessible parking spaces to the primary entrance of the tenant space. Please provide detailed plans of the path of travel, indicate slope and width, any pedestrian ramps, curb ramps, walks, handrails, provide dimensioned parking stall details etc. It is unclear from the plans if the restrooms servicing the tenant improvement are disabled accessible, please provide a dimensioned restroom plans showing the restroom to be accessible compliant. The plans apear to show a fixed piece of equipment in the reception as the reception counter. Service counters shall have a portion of the counter which is at least 36" in length with a maximum height of 34 inches. Section 11B-904.4.1. City of Carlsbad 14-1523 7/10/14 Please correct the plans the new doors 2301, 2201, 1001 and 1101 are shown on the plans to be 30" doors yet the door schedule shows them as 36". Show that the minimum strike edge distances are provided at the level area on the side to which a door (or a gate) swings, per Section 11 B-404.2.4: a) ~!18" at interior conditions for door 2601 and 2201. 14. Show a level area, or landing, per Section 11 B-404.2.4: a) ~!60" in the direction of door swing for doors 1101 -and 1001. 15. Please clarify the plans to how the Phone and Video Booth will be made disabled accessible? • To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. . • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes D' , No 0 • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any • questions regarding these plan review items, please contact Doug Moody at • . Esgil Corporation. Thank you. 0 11 City of Carlsbad 14-1523 7/10/14 [DO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 14-1523 PREPARED BY: Doug Moody DATE: 7/10/14 BUILDING ADDRESS: 2701 Loker Ave West Suite 250 BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: lB. BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) TI 7040 37.12 261,325 Air Conditioning Fire Sprinklers TOTAL VALUE . 261,325 Jurisdiction Code Icb IBY Ordinance I ____________ Bldg.Perm& Fee by Ordinance . I $1,330.66 I Plan Check Fee by Ordinance S I $864.93 Type of Review: Complete Review Structural Only Repetibve Fee . Other Repeats Hourly Hr. © * EsGil Fee 1 $745.171 Comments: S Sheet of 1 macvalue.doc + X, PLAN CHECK Community& Economic REVIEW Development Department - . CITY. OF V I VV 1635 Faraday Avenue CARLSBAD TRANSMITTAL Carlsbad CA 92008 DATE: 7/17/2014 PROJECT NAME: Personal Strengths Publishing tenant imp PROJECT ID: PLAN CHECK NO: CB14-1523 SET#:' ADDRESS: 2701 Loker Avenue West Ste 250 APN: 209.081-22 VALUATION: $261,325 APPLICANT CONTACT: rob@robnelsonad.com Tlis plan check review transmittal is to notify you of clearance by: >< LAND DEVELOPMENT ENGINEERING DIVISION Final Inspection by the Construction & Inspection Division is required Yes rLj No';--, For status from a division not marked below, please call 760-602-2719 This plan check review is NICOMPLETE Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. - All i~ltl WA. [~CA~ N D, D EVE LO P M E NT, E N G!t '74 - 1 Chris Sexton .LJ 760-602-4624 Chris.Sextoti@carlsbadca.gov 1 Kathleen Lawrence ._J 760-602-2741 Kathleen. Lawrence@carlsbadca.gov LEI Greg Ryan. 760-602-4663 Gregory.Rya n@carisbadca.gov El GinaRuiz 760-602-4675 . Gina.Ruiz@carlsbadca.gov - Linda Ontiveros . 760-602-2773 Linda.Ontiveros@carlsbadca.gov Cindy Wong 760-602-4662 Cynthia.Wong@carlsbadca.gov r . - -• . Dale Willis 760-602-2784 Dale.Willis@carlsbadca.gov [1 DominicFieri L—J 760-602-4664 Dominic.Fieri@carlsbadca.gov . ;Remarks: . -. r PLANNING DIVISION BUILDING PLAN CHECK Development Services 01anning Division CITY OF APPROVAL. 1635 Faràday Avenue (760) 602-4610 CARLSBAD P-29, - DATE 6/30/14 PROJECT NAME Ti PROJECT ID PLAN CHECK NO CB141523 SET# 'ADDRESS: 2701 LOKERAV W42 5-OrAPN This plan check review is+compIete'and has been APPROVED by the PLANNING Division By GINA RUiZ - A Final Inspection by the PLANN1NG'Divisiôhis required' Ys , No : You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. ' Resubmitted plans should include corrections from all divisionà. This plan check review is NOT COMPLETE. Items thisihg'orincórréct are listed on the attached checklist. Please resubmit amended plansas-required. Plan Check APPROVAL has been sent- to. ROB@ROBNELSONAD.àOM ' For questions or clarifications on the-attached checkiit'piéae contact the following reviewer astharkCd: y - PLANNlNG - - - ENGINEERING ' - FIRE PREVENTION , I ' - '- I 7606024610 • r -'---' 7606022750 f - 7606024665 ,. ''•- 1r,:- ;:-- • ;'-: Chris Sexton KathleenL.àrencO Gieg Ryan 760-602-4624 - 76(Y-602-2741 -760-602-4663 Chris.Sexton@carisbadca.gov Káthieen.Lawei,ce@carIsbadca.gov Greorv.Ryan@carlsbadca.ov Gina Ruiz Linda Ontiveros n Cindy Wong 760-602-4675 760-602-2773 - 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov • Dominic Fieri 760-602-4664 Dominic.Fieri@c3risbadca.gov Remarks: - -•,- • .' ------• - •-. :- -- _ r munuty& Economic PLAN CHECK 1635 Faraday Avenue ITY OF REVIEW Development Department CARLS.DJ6% D A TRANSMITTAL. Carlsbad CA 92008 LJ BLDG. DEPT Lcarisbadca.gov DATE: 8/28/14 PROJECT NAME: Personal Strengths . PROJETlD: :. t 'C •' PLAN CHECK NO: CB141523 SET#: 3 ADDRESS: 2701 Loker Ave West APN: 7. This plan check review is complete and has been APPROVED by the Fire Division I - By D Fled - A Final Inspection by the Fire Division is required Yes No This plan check review is NOT COMPLETE Items missing or incorrect are listed on -. the attached checklist. Please resubmit amendedplans as required. C'' C • . .' " --- - . ' ,C . . fl 3__ / . - . • A Plan Check Comments have been sent to .•-.-'- '• ' . .- '4. ' S You may also have corrections from one or more of the divisions listed Lielow Approval from these divisions may be required prior to the issuance of a building permit Resubmitted plans should include corrections from all divisions ,. •'For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 . 760-602-2750 .760-602-4665 Chris Sexton Kathleen Lawrence Greg Ryan -. 760-602-4624 '. 760-602-2741 '- -' ' 760.602-4663 Chris.Sexton©carisbadca.ov . Kath lee n.Lawrence@carisbadcagov ' -. Gregory.Ryan@carisbadca.gov J-., Gina Ruiz - - - Linda Ontiveros - '- -.• - . Cindy Wong ' '760-602-4675. ' 5_. - -.- 760-602-2773 - - , 760-602-4662 Gina.Ruiz@carisbadca.ov . Linda.Ontiveros@carlsbadca.gov Cvnthia.Won@carisbadca.ov - El Dominic Fieri 'C C- 760-602-4664 'S Dominic.Fieri@carisbadca.gov BLDO T Carlsbad Fire Department . .: Plan Review :. Requirethents Categor: TI, 1NDUST I 'I Date of Report 0&28-2014 Reviewed by - - - .5 ,.. I •• Name:. ROB NELSON * . Address:• STE 210A' . . - 7O516THST SAN DIEGO CA . . 92101 ..• •. . • . Perrnitl CB141523 Job Name: PERSONAL STRENGTHS- 7.040 SF .. Job Address: 2701 LOKER AV WEST CBAD St: 250 r • COMPL E e item you ave - •tted for re ew is oniplete. t t e, this o cc ot ade ely con uct a rev to dete flC Co cc wit the app li e cod an or ndards. Pleas evi 'carefully co to this office ents d Plea resubmit t eces ry plans an sp ilications th c ges u edo, Cond' C0N0007652 I - • ,.• THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT: •: - . -- THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON. CONDITIONS IN . : .. .CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. . ,,.THIS 'APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROV91 THE VIOLATION OF ANY LAW. Entry: 08/28/2014 By: df Action: AP - - . • . S Cond:C0N0007531 • . -. • [NOT MET]. - . . - .•'. -' . - • - . ShetA1O, N5 - ra to be maintained 0101 3.Sheet-2.O: Code lock on p ebooth (022). Please provide ex p ationof "code lock". Provide manufac 's cut sheets illustratin at it shall complies with the folio g: Card Readers and si Har shall not inhibit e s. All card readers shall disenga n the case of wer outage or water w. This will be demon ted at acceptance testing. All bc on the egr shall be mechanical. controlled access use the egress side, section 1008.1. . of the Califo Fire Code shall be . S Include Gene Fire Notes Section. 5 Provide manufactur ' cut sheets for finis s (Sheet A-2.2). Refere appropriate class per Section 803.3, CFC, 2014 ition. 6. Add door 0502 to sheet A-6.0. S S Entry: 08/04/2014 By: cwong ction: CO 4V V - PLAN CHECK t Community & Economic 401, h V REVIEW Development Department CITY OF V 1635 Faraday Avenue CARLSBAD TRANSMTJ1 DEPT COPY wCarlsbad CA 92008 Sd DATE 08/4/14 PROJECT NAME personal strengths publishing PROJECT ID PLAN CHECK NO cb141523 SET# I ADDRESS 2701 ioker ave west APN This plan check review is complete and has been APPROVED by the fire Division By cwong A Final Inspection by the Division is required 2 Yes El No This plan check review is NOT COMPLETE Items missing or incorrect are listed on the attached checklist Please resubmit amended plans as required 4 Plan Check Comments have been sent to robrobne1sonad corn (hard copy sent via USPS) * You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit 4 Resubmitted plans should include corrections from all divisions For questions or clarifications on the attached checklist please contact the following reviewer as marked PLANNING ENGINEERING FIRE PREVENTION 1 760-602-4610 760-602-2756Ir 760-6024665 -. Chris Sexton : Kathleen Lawrence . Greg Ryan 760-602-4624 - 760-602-2741 760-602-4663 V -: Chris.Sexton@carIsbadca.gov V KathIeen.Lawrence@carIsbadca.gov Gregory.Ryan@carIsbadca.gov - Gina Ruiz Linda Ontiveros Cindy Wong .760-602-4675 760-602-2773 760-602-4662 V V 'Gina.Ruiz@carlsbadca.gov Linda Ontiveros@carlsbadca gov Cynthia Wong@carlsbadca ov El Dominic Fieri 760-602-4664 Dominic.Fieri@ceirlsbadca.gov Carlsbad Fire Department Plan Review Requirements Category: TI , INDUST Date of Report: 08-04-2014 Name: ROB NELSON Address: STE 210A 705 16TH ST SAN DIEGO CA 92101 Reviewed by: Permit #: CB141523 Job Name: PERSONAL STRENGTHS- 7,040 SF Job Address: 2701 LOKER AV WEST CBAD St: 250 INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review• carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Cond:C0N0007531 [NOT MET] ***Bubble All Changes*** Sheet T- 1.0: OL calculations per Table 1004.1.2. Account for areas not considered "business" e.g. Training Room, Dining Lounge, Reception, Conference. Sheet G-2.0: Existing dimising wall shall be identified as existing 1 HR corridor (including but not limited to sheets: A1.0,A2.2,A3.0). Sheet A- 1.0, N5.- rating to be maintained 0101 Sheet A-2.0: Code lock on phonebooth (022). Please provide explanation of "code lock". Provide manufacturer's cut sheets illustrating. that it shall complies with the following: Card Readers and similar shall not inhibit.egress. All card readers shall disengage in the case of power outage or water flow. This will be demonstrated at acceptance testing. All locks on the egress shall be mechanical. If controlled access used on the egress side, section 1008.1.3.4 of the California Fire Code shall be met. Include General Fire Notes Section. Provide manufacturer's cut sheets for finishes (Sheet A-2.2). Reference appropriate class per Section 803.3, CFC, 2014 edition. 6. Adddoor 0502 to sheet A-6.0. Entry: 08/94/2014 By: cwong Action: CO