HomeMy WebLinkAbout2702 GATEWAY RD; ; CB081806; Permit02-02-2009 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB081806 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title Applicant PHILIP CUDABACK 2702 GATEWAY RD CBAD Tl Sub Type INDUST 2132631300 Lot# 0 Status $40,985 00 Construction Type 5B Applied Reference # Entered By PACIFIC CNC MACHINE CO-1171 SF Plan Approved SHELL TO OFFICE (REMAINING 4726 SF TO REMAIN AS IS AND Issued Inspect Area Plan Check* Owner ISSUED 09/22/2008 RMA 02/02/2009 02/02/2009 STE 129 255 G STREET 92101 858 357-5509 SPECTRUMFLEX LLC 406 9TH AVE #309 SAN DIEGO CA 92101 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee Green Bldg Stands (SB1473) Fee $359 43 Meter Size $0 00 Add'l Reel Water Con Fee $233 63 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $861 PFF (3105540) $0 00 PFF (4305540) $000 License Tax (3104193) $0 00 License Tax (4304193) $000 Traffic Impact Fee (3105541) $000 Traffic Impact Fee (4305541) $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $5,060 00 Master Drainage Fee D3/4 Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees ?? HMP Fee TOTAL PERMIT FEES $000 $364 00 $4.492 00 $000 $741 83 $000 $000 $000 $1,36000 $000 $12500 $41000 $7450 $000 $861 84 $000 $000 77 $14,09084 Total Fees $14,09084 Total Payments To Date $14,090 84 Balance Due $000 PLANS RAGE NOTICE Please take NOTICE thaoapproval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You»have 90 days from the date this permit was issued to protest imposition of these fees'exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will ba- any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to wate1 jnd sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this pro|i"~t NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations r as previously otherwise expired City of Carlsbad 1635 Faraday Ave , Carlsbad, CA 92008 760-602-2717 / 2718 / 2719 Fax 760-602-8558 » www carlsbadca gov Building Permit Application Plan Check No. Est. Value Plan Ck. Deposit Date JOB ADDRESS SUITE#/SPACE#/UNIT# CT/PROJECT #PHASE ## BEDROOMS # BATHROOMS TENANT BUSINESS NAME (~CONSTR TYPE DESCRIPTION OF WORK /nc/ucte Square Feet of Affected At ea(s)rc^t ui rtifcificu i-uf*a\vj _ ^ /;/?/ /# / fa 7/Ig/lM rz..MdMT EXISTI •PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE YESD #NO D AIR CONDITIONING YES D NOD FIRE SPRINKLERS YES D NOD CONTACT NAME (If Different Fom Applicant; ADDRESS APPLICANT NAME ADDRESS -S.T CITY STATE ZIP CITY STATE ZIP PHONE FAX PHONE FAX EMAIL EMAIL ^^c=CONTR1PROPERTY OWNER NAME ACTOR BUS NAME/%L- i ADDRESS ADDRESS CITY STATE ZIP CITY STATE ZIP PHONE &7Z'/?FAX PHONE FAX EMAIL EMAIL fARCH/DESlGlteR NAME & ADDRESS STATE LIC #STATE LIC # TO CLASS CITY BUS LIC# (Sec 7031S Business and Professions Code Any City or County which requires a permit to construct alter, improve, demolishNcrepair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he islicensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of tnraiiyness and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption Any violation ofSection 7031S by any applicant for a permit subjects the applicant to a cml penalty of not more than five hundred dollars {$500}) \ Workers' Compensation Declaration / hereby affirm under penalty of perjury one of the following declarations 3^1 have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued [S^fhave and will maintain workers' compensation, as required by Section 3700 ol the Labor Code, lot the performance of the work lor which this permit is issued My workers' compensation insurance carrier and policy number are Insurance Co O\g>V Cfe.yjiat.'c 6-»A^a^~>l ^V^ /3 TO Policy No '3 L^T-^feM fc Expiration Date -J')-^7 This section need not be completed if the permit is for one hundred dollars ($100) or less C3 Certificate of Exemption I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees -T^T CONTRACTOR SIGNATURE DATE / hereby affirm that I am exempt from Contractor's License Law for the following reason D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If however, the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) CJ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law) n I am exempt under Section Business and Professions Code lor this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement O Yes d No 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name.' address / phone / type of work) ^PROPERTY OWNER SIGNATURE DATE Is the applicant or future building occupant required to submit a business plan acutely hazardous matenals registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley Tanner Hazardous Substance Account Act' a Yes a No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district'' a Yes O No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site' a Yes d No IF ANY OF THE ANSWERS ARE YES, / EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT ' I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code) Render's Name Lender's Address I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to buildingconstructon I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRACING OF THIS PERMIT OSH A An OSHA permit B required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit B not commenced within 180 days from the date of such permit or ifthe buttng or work authorized by such permit B suspended or abandoned at any time after the work B commenced for a penod of 180 days (Section 106 4 4 Uniform Building Code) ^APPLICANT'S SIGNATURE f^7l*\ £ * /? &L DATE 7 City of Carlsbad Final Building Inspection Dept Building Engineering Planning CMWD St Lite Fire Plan Check # Permit* Project Name Address Contact Person Sewer Dist Inspected // Bv M Inspected Bv Inspected Bv CB081806 PACIFIC CNC MACHINE CO-1 171 SF SHELL TO OFFICE (REMAINING 4726 SF TO 2702 GATEWAY RD JEFF CA K7' r Phone 8585831509 Water Dist CA Date / / Inspected £-////£ Date ' Inspected Date Inspected Date Permit Type Sub Type REMAIN AS Lot 0 '., /?f Approved 6^ Approved Approved 03/11/2009 Tl INDUST ^- Disapproved Disapproved Disapproved Comments City of Carlsbad Bldg Inspection Request For 03/11/2009 Permit* CB081806 Title PACIFIC CNC MACHINE CO-1171 SF Inspector Assignment PY Description SHELL TO OFFICE (REMAINING 4726 SF TO REMAIN AS IS AND BE USED AS WAREHOUSE) Sub Type INDUSTType Tl Job Address 2702 GATEWAY RD Suite Lot 0 Location OWNER SPECTRUMFLEX LLC Owner SPECTRUMFLEX LLC Remarks a m please Total Time Phone 8585831509 Inspector Requested By JEFF Entered By CHRISTINE CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act Comments Comments/Notices/Holds Associated PCRs/CVs Original PC# Date 03/09/2009 03/05/2009 03/04/2009 02/24/2009 02/23/2009 02/19/2009 02/19/2009 02/19/2009 02/18/2009 02/17/2009 02/13/2009 02/12/2009 Inspection History Description 39 Final Electrical 84 Rough Combo 84 Rough Combo 17 Interior Lath/Drywall 17 Interior Lath/Drywall 14 Frame/Steel/Bolting/Welding 24 Rough/Topout 34 Rough Electric 14 Frame/Steel/Bolting/Welding 14 Frame/Steel/Bolting/Welding 14 Frame/Steel/Bolting/Welding 24 Rough/Topout Act PA AP NR AP AP AP CO AP NR NS CO CO Insp PY PY PY PY PY PY PY PY PY PY MC TP Comments EMR T-BAR - UPDATE ELECT CHANGES HANDICAP RAMP? need revision for underground & need top out NEED PLANS REVISED NOTICE PNDING ON 2 IN MOP SINK APPROVAL (PLN /SPECS SIN) CITY OF CARLSBAD ADDRESS: ELECTRIC AND GAS METER CLEARANCE INTER-DEPARTMENT 2- S E O Service Equipment Only Reason, If Denied ELECTRIC METER GAS METER COMMERCIAL RESIDENCE NEW SERVICE RELOCATE T'SPB TEMP P/P UP-GRADE TEST METER IRR PEDESTAL COMMERCIAL RESIDENCE TEST METE YES NO YES NO YES NO Time Called In By Time Called In To City of Carlsbad Bldg Inspection Request For 03/09/2009 Permit# CB081806 Title PACIFIC CMC MACHINE CO-1171 SF Inspector Assignment PY Description SHELL TO OFFICE (REMAINING 4726 SF TO REMAIN AS IS AND BE USED AS WAREHOUSE) 2702 GATEWAY RD Lot Type Tl Job Address Suite Location OWNER SPECTRUMFLEX LLC Owner SPECTRUMFLEX LLC Remarks Sub Type INDUST Phone 8585831509 Inspector Total Time Requested By JEFF Entered By CHRISTINE CD Description 39 Final Electrical Act Comments Comments/Notices/Holds Associated PCRs/CVs Original PC# Date 03/05/2009 03/04/2009 02/24/2009 02/23/2009 02/19/2009 02/19/2009 02/19/2009 02/18/2009 02/17/2009 02/13/2009 02/12/2009 Inspection Historv Description 84 Rough Combo 84 Rough Combo 17 Interior Lath/Drywall 17 Interior Lath/Drywall 14 Frame/Steel/Bolting/Welding 24 Rough/Topout 34 Rough Electric 14 Frame/Steel/Bolting/Welding 14 Frame/Steel/Bolting/Welding 14 Frame/Steel/Bolting/Welding 24 Rough/Topout Act AP NR AP AP AP CO AP NR NS CO CO Insp PY PY PY PY PY PY PY PY PY MC TP Comments T-BAR - UPDATE ELECT CHANGES HANDICAP RAMP? need revision for underground & need top out NEED PLANS REVISED NOTICE PNDING ON 2 IN MOP SINK APPROVAL (PLN /SPECS 3IN) CITY OF CARLSBAD ELECTRIC AND GAS METER CLEARANCE INTER-DEPARTMENT ADDRESS: S E O Service Equipment Only Reason, If Denied ELECTRIC METER GAS METER COMMERCIAL RESIDENCE NEW SERVICE RELOCATE TSPB TEMP P/P UP-GRADE TEST METER IRR PEDESTAL COMMERCIAL RESIDENCE TEST METER Building (Inspector Signature Called In By YES NO YES NO YES NO Date Time Date Time Called In To City of Carlsbad Bldg Inspection Request For 02/13/2009 Permit* CB081806 Inspector Assignment PY Title PACIFIC CMC MACHINE CO-1171 SF Description SHELL TO OFFICE (REMAINING 4726 SF TO REMAIN AS IS AND BE USED AS WAREHOUSE) Type Tl Sub Type INDUST Phone 8586883077 Job Address 2702 GATEWAY RD Suite Lot 0 Location Inspector APPLICANT PHILIP CUDABACK Owner SPECTRUMFLEX LLC Remarks Total Time Requested By NA Entered By CHRISTINE CD Description Act Comments 14 Frame/Steel/Boltmg/Weldmg Comments/Notices/Holds Associated PCRs/CVs Original PC# Inspection History Date Description Act Insp Comments 02/12/2009 24 Rough/Topout CO TP PNDING ON 2 IN MOP SINK APPROVAL (PLN/SPECS SIN) NOTICECITY OF CARLSBAD ^.- -„ (760)602-2700 BUILDING DEPARTMENT 1635 FARADAY AVENUE DATE fe fe£> 05 TIME _ LOCATION '2.1*3 2- PERMIT NO £.£> Og>\ 6nr A~7.fr /uer 1 At4l> FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? i _ I YES FOR FURTHER INFORMATION, CONTACT __ 6^2-' "2^? K . |M PHONE BUILDING INSPECTOR CODE ENFORCEMENT OFFICER EsGil Corporation In Partners/tip with government for (Building Safety DATE 10/27/08 JURISDICTION City of Carlsbad FILE PLAN CHECK NO 08-1806 SET III PROJECT ADDRESS 2702 Gateway Rd PROJECT NAME Pacific CNC Machine Co. - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes ><] The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to XI Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person REMARKS Applicant to add notes in red on sheet E-3 to City held sets By Doug Moody - Enclosures Esgil Corporation D GA D MB D EJ D PC 10/20/08 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560-1576 EsGil Corporation In (partnership with government for <Bui[<fmg Safety DATE 1O/16/O8 OAPPLICANT ^JURISDICTION City of Carlsbad a FILE PLAN CHECK NO 08-18O6 SET II PROJECT ADDRESS 27O2 Gateway Rd PROJECT NAME Pacific CNC Machine Co. - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck Xl The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person X3 The applicant's copy of the check list has been sent to Philip Cudaback 225 G Street, San Diego, CA 92101 Esgil Corporation staff did not advise the applicant that the plan check has been completed ><] Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Philip Cudaback Telephone # 858-357-5509 Date contacted {^l^f^^-^0 Fax # 619-528-1198 Mail ^Telephone Fax /In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 10/9/08 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 Gity tff Carlsbad 08-1806 1O/16/O8 RECHECK CORRECTION LIST JURISDICTION City of Carlsbad PLAN CHECK NO 08-1806 PROJECT ADDRESS 2702 Gateway Rd SET II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 10/9/08 10/16/08 REVIEWED BY Doug Moody FOREWORD (PLEASE READ). This plan review is limited to the technical requirements contained in the Building Code, Plumbing Code, Mechanical Code, Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations The approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit new complete sets of prints to B To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? aYes aNo City tff Carlsbad O8-1806 10/16/O8 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 4 Please revise the single line to show the mam over-current device feeding panel C to be 100 amps or size tho fooder conduit and conductors for 225 amps Please revise the single line diagram to show the grounding of the new service. Please indicate why a 400 amp over-current device is feeding a 225 amp panel? Is this panel going to have a 225 amp over-current device installed to protect the panel7 7 Ploase revise the plumbing plans to show the total aggregate vent area to bo equal to tho required sewer size per section 904 1 of the UPC (A minimum of 7 06 square inches) The two 2" vents connected to the 3" vent thru the roof is not adequate. Please revise the waste line. 8 Please clarify the wasto line plan to show all pipo sizes Not all pipe sizes are shown. Please compete the waste line diagram 10 Ploase revise the plans to show the non-commercial kitchen sink in the employee staff room to provide tho following Please revise the section of the sink as shown in detail 1 on A9 0 a) A clear floor space at least 30"x 48" shall be provided for forward approach b) The clear space shall extend a maximum of 19" underneath the sink c) The accessible sink shall be a maximum of 6 Vz deep d) Tho sink shall bo mounted with the counter or rim no higher than 34" e) Knee clearance that is at least 27" high, 30" sido and 19" underneath tho sink shall be provided f) Hot water and dram shall be insulated g) There shall bo no sharp or abrasive surfaces under sinks 12 Doors in the room shall not swing into the clear floor space required for any fixture Maintain the required clearances at the lavatory/water closet without the entry door City 6f Carlsbad O8-18O6 1O/16/08 swinging into those areas Section 1115B 3 2 2 The dimensions shown in detail 9 on sheet AS 0 will provide the required clearance only if a 24" water closet is installed9 Please provide the catalog cut sheet showing the 24" water closet to be an elongated bowl and disabled accessible To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes a No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you EsGii Corporation In (Partnership -with government for <BuiCd~ing Safety DATE 9/29/O8 D APPLICANT JURISDICTION City of Carlsbad a PLAN^EVIEWER a FiLt PLAN CHECK NO 08-1806 SET I PROJECT ADDRESS 2702 Gateway Rd PROJECT NAME Pacific CNC Machine Co. - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted fora complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Philip Cudaback 225 G Street, San Diego, CA 92101 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Philip Cudaback Telephone # 858-357-5509 Date contacted ^fafatyoy^A^ Fax # 619-528-1198 Mail^' Telephone Fax^ In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ n PC 9/23/08 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 City of Carlsbad 9/29/08 O8-1806 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO O8-1806 OCCUPANCY B TYPE OF CONSTRUCTION VB ALLOWABLE FLOOR AREA SPRINKLERS'? No REMARKS DATE PLANS RECEIVED BY JURISDICTION 9/22/08 DATE INITIAL PLAN REVIEW COMPLETED 9/29/08 JURISDICTION City of Carlsbad USE Office ACTUAL AREA 1171sf STORIES 1 HEIGHT OCCUPANT LOAD 25 DATE PLANS RECEIVED BY ESGIL CORPORATION 9/23/08 PLAN REVIEWER Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit' -Code sections c4ed are based on the 2007 CBC, which adopts the 2006 IBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 105 4 of the 2006 International Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i e , plan sheet number, specification section, etc Be sure to enclose the marked up list when you submit the revised plans City of Carlsbad O8-18O6 9/29/08 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1 Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the 540# rooftop air handler unit Include all calculations and finding on the plans Please include the California license number, seal, date of license expiration and date plans are signed Business and Professions Code 2 Please review the requirements, revise the plans appropriately and imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans 3 Please note in the general wiring notes on the plans "AC Cable is not allowed in A, B, E, H, F, M, S and I occupancies NM cable is restricted (without City approval) to one and two family dwellings Note on plans that an equipment ground conductor is to be installed in all flexible conduits" 4 Please revise the single line to show the main over-current device feeding panel C to-be 100 amps or size the feeder conduit and conductors for 225 amps 5 Please correct the LTG-1 -C part 4 of 4 document to show occupancy sensors and not an automatic time switch 6 Please complete the LTG-1-C form to be consistent with the plans 7 Please revise the plumbing plans to show the total aggregate vent area to be equal to the required sewer size per section 904 1 of the UPC (A minimum of 7 06 square inches) 8 Please clarify the waste line plan to show all pipe sizes 9 Provide separate restroom facilities for each sex as per UPC, Section 412 1 City of Carlsbad 08-1806 9/29/08 10 Please revise the plans to show the non-commercial kitchen sink in the employee staff room to provide the following a) A clear floor space at least 30"x 48" shall be provided for forward . approach b) The clear space shall extend a maximum of 19" underneath the sink c) The accessible sink shall be a maximum of 6 1/2" deep d) The sink shall be mounted with the counter or rim no higher than 34" e) Knee clearance that is at least 27" high, 30" side and 19" underneath the sink shall be provided f) Hot water and dram shall be insulated g) There shall be no sharp or abrasive surfaces under sinks 11 Show that the water closet is located in a space, per Section 1115B 3 2 3, which provides a) A minimum side clearance of either i) >28" from a fixture n) >32" from a wall on one side b) A clear space in front of the water closet measuring 60" wide by 48" in front Section 1115B41 2 12 Doors in the room shall not swing into the clear floor space required for any fixture Maintain the required clearances at the lavatory/water closet without the entry door swinging into those areas Section 1115B 3 2 2 13 Show that grab bars comply with the following, per Section 1115B 8 h) They shall be securely attached 33" above the floor, and parallel / i) NOTE Where a tank-type toilet is used which obstructs placement of the rear grab bar at 33", the rear grab bar only may be installed as high as 36" 14 Plans shall indicate that drinking fountains comply with Section 1115B 4 6 as either a) Located completely in an alcove, >32" in width and >18" in depth b) Positioned to not encroach into accessible pedestrian ways To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc City of Carlsbad 08-18O6 9/29/O8 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes a No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you CITY OF CARLSBAD POLICIES AND PROCEDURE NUMBER 80-6 SUBJECT ROOF MOUNTED EQUIPMENT EFFECTIVE 5/1/92 SECTION BUILDING DEPARTMENT SUPERSEDES 80-6(9/10/80) 80-6(5/01/81) PURPOSE INTENT PROVIDE INSTALLATION STANDARDS FOR ALL ROOF MOUNTED EQUIPMENT AND PENETRATIONS ON COMMERCIAL AND INDUSTRIAL BUILDINGS A Maintain roof integrity B Prevent hazardous condition to firemen who must fight fire on the roof C Provide an installation that is aesthetically sensitive to the building and the adjoining properties POLICY 1 All equipment shall be concealed from view and the design* shall meet the approval of the Planning Department. 2 All equipment shall be specifically designed and approved for exterior use and ' shall be approved by the City of Carlsbad Building Department 3 All roof mounted equipment shall be on a platform which shall be an integral part of the roof-flashed and waterproofed When a screen is approved, it shall have as few roof connections as possible and be structurally adequate 4 All electrical, plumbing, mechanical duct work and related piping shall be inside the building and not on the roof All connections related to equipment shall be made in the same roof opening on the platform or have the prior approval from the building official 5 Sewer vents shall be brought to one mam vent below the roof and have one penetration where restrooms or other plumbing fixtures are back to back or in the general proximity. Air exhaust fans and other equipment shall be within the building and use the same roof opening where restrodms and other equipment are back to back or in general proximity 6 Existing buildings and equipment, remodel or replacement, shall meet the above regulations or shall have the prior approval from the building official 7 Where new equipment is installed, unused or abandoned equipment, including all roof mounted piping, electrical, mechanical, duct, and other related appurtenances shall be removed from roof and unused openings properly sealed to maintain roof integrity *The architect should, through design, conceal the heating/AC unit and other equipment whether they are on the roof or elsewhere tiated By Approved B City of Carlsbad O8-1806 9/29/08 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO 08-1806 PREPARED BY Doug Moody DATE 9/29/08 BUILDING ADDRESS 2702 Gateway Rd BUILDING OCCUPANCY B TYPE OF CONSTRUCTION VB BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 1171 cb Valuation Multiplier 34 37 By Ordinance Reg Mod VALUE (S) 40,247 40,247 $331 71 Plan Check Fee by Ordinance ^ Type of Review 0 Complete Review I I Repetitive Fee: Repeats D Other ,—i Hourly Structural Only Hour* $21561 Esgil Plan Review Fee $18576 Comments Sheet 1 of 1 macvalue doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CBflfi/866, ADDRESS RESIDENTIAL RESIDENTIAL ADDITION MINOR (<$10,000.00) DATE , TENANT IMPROVEMENT CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER 1,171 PLANNER ENGINE DATE Address Prepared by ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET stimate based on unconfirmed information from applicant Calculation based on building plancheck plan submittal NL*Bldg. Permit No Checked byT^ r EDU CALCULATIONS:. List types gnd square footages for all uses "~ /££/, fa-fJs-*^) <fl**id~'<&<' L£~Lo-S) TyperoTuse Sq Ft/Units Date Sq Ft/Units.Types of Use APT CALCULATIONS: List types and square foqtages for all uses e^O 5\-eAs£~~<PfY' de^^cjij Sq Ft/Units Types of Use Sq Ft/Units EDU's EDU's ADT's . ADT's FEES REQUIRED: WITHIN CFD 0YIYES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee)DNO PARK-IN-LIEU FEE FEE/UNIT PARK AREA & # X NO UNITS 2 TRAFFIC IMPACT FEE ADT'S/UNITS rz FEE/ADTrBRIDGE AND THOROUGHFARE FEE (DIST #1 DIST #2 . - ADT's/UNITS |oAl<FACIUTIES MANAGEMENT FEEr /UNIT/SQ FT 5 SEWER FEE EDU'S , X FEE/ADT ZONE X FEE/SO FT/UNIT BENEFIT AREA EDU's i FEE/EDU FEE/EDU 67 (f =$_ =$_ 6 SEWER LATERAL ($2,500) 7 DRAINAGE FEES PLDA_ ACRES HIGH. X FEE/AC /LOW =$_ 8 POTABLE WATER FEES UNITS CODE CONNECTION FEE \t METER FEE /S°CWA FEE SDCWA FEE F VFEE CALCULATION WORKSHEET doc 1 of 2 Rev 7/14/00 Storm Water Compliance Exemption Form I am applying to the City of Carlsbad for the following type(s) of construction permit Building Permit Q Right-of-Way Permit Q My project is categorically EXEMPT from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it only requires issuance of one or more of the following permit types Electrical Fire Additional Fire Alarm Fixed Systems Mechanical Mobile Home Plumbing Patio/Deck Re-Roofing Sign Spa-Factory Sprinkler Water Discharge Project Storm Water Threat Assessment Criteria No Threat Assessment Criteria *My project qualifies as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it meets the "no threat" assessment criteria on the City's Project Threat Assessment Worksheet for Determination of Construction SWPPP Tier Level My project does not meet any of the High, Moderate or Low Threat criteria described below Tierl - Low Threat Assessment Criteria Q My project does not meet any of the Significant or Moderate Threat criteria, is not an exempt permit type (See list above) and the project meets one or more of the following criteria • Results in some soil disturbance, and/or • Includes outdoor construction activities (such as roofing, saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling) Tier 2 - Moderate Threat Assessment Criteria Q My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria • Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 1 5 1 6 of the Carlsbad Municipal Code), or, • Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria • Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or • Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or • Disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse, and/or • Construction will be initiated during the rainy season or will extend into the rainy season (Oct 1 through April 30) Tier 3 - Significant Threat Assessment Criteria a My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas and/or Q My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, refueling and maintenance areas or, Q My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s) / certify to the best of my knowledge that the above checked statements are true and correct I understand and acknowledge that even though this project does not require preparation of a construction SWPP, I must still adhere to, and at all times during construction activities for the permit type(s) check above comply with the storm water best management practices pursuant to Title 15 of the Carlsbad Municipal Code and to City Standards 'The City Engineer may authorize minor variances from the Storm Water Threat Assessment Criteria in special circumstances where it can be shown that a lesser or higher Construction SWPPP Tier Level is warranted Project Address Assessor Parcel No Owner/Owner's Authorized Agent Name Owner/Owner's Authorized Agent Signature 6«**Q - — \ ^^CityCoricurrence >dvEs a NO Title Date Project ID C&M/fflfo Q S S 5 So o o D D D D D D D D PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No C608-1806 Address 2702 Gateway Rd Planner ChriFSiexton Phone (760) 602- 462^ APN 213-263-13 Type of Project & Use JJNet Project Density DU/AC Zoning P-C General Plan P-l Facilities Management Zone 17 CFD (in/out) #_Date of participation Remaining net dev acres. Circle One (For non-residential development Type of land used created by this permit Legend. ^ Item Complete D Item Incomplete - Needs your action Environmental Review Required: YES D NO [3 TYPE DATE OF COMPLETION _ Compliance with conditions of approval? If not, state conditions which require action Conditions of Approval _ Discretionary Action Required: APPROVAL/RESO NO _ DATE PROJECT NO _ OTHER RELATED CASES _ YES D NO Kl TYPE Compliance with conditions or approval7 If not, state conditions which require action Conditions of Approval Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES Q NO j^ CA Coastal Commission Authority? YES Q NO D If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402, (619) 767-2370 Determine status (Coastal Permit Required or Exempt) Habitat Management Plan Data Entry Completed? YES D NO E3 If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE') Inclusionary Housing Fee required- YES D NO Kl (Effective date of Inclusionary Housing Ordinance - May 21, 1993 ) Data Entry Completed? YES D NO D (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATEi) H \ADMIN\Template\Buildmg Plancheck Review Checklist doc Rev 4/08 Site Plan El D D Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes) Provide legal description of property and assessor's parcel number Policy 44 - Neighborhood Architectural Design Guidelines ISI D D 1 Applicability YES D NO Kl D D D 2 Project complies YES D D D Zoning- 1 Setbacks Front Interior Side Street Side Rear Top of slope Required Shown Required Shown Required Shown Required' Shown Required Shown 2 Accessory structure setbacks Front Interior Side Street Side Rear Structure separation Required Required Required Required Required Shown Shown Shown Shown Shown D D 3 Lot Coverage 4 Height Required Shown Required Shown D Spaces Required Shown5 Parking (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments 1) Please see handouts Please show parking breakdown per use and square footage 2) Will there be any new roof mounted equipment? If so. please show how it will be screened lofJSJg S OK TO ISSUE ANDNlTERED APPROVALONTO COMPUTER H \ADMIN\Template\Buildmg Plancheck Review Checklist doc Rev 4/08 Carlsbad Fire Department Plan Review Requirements Category TI. INDUST Date of Report 10-22-2008 PHILIP CUDABACK Reviewed by Name Address STE 129 255 G STREET SAN DIEGO CA92101 BLDG. DEFT COPY Permit # CB081806 Job Name PACIFIC CNC MACHINE CO-1171 SF Job Address 2702 GATEWAY RD CBAD submitted for review is incomplete adequately conduct a rpview tn feiffouj^T^^ anH/r>r standards Pleasereview" -^^^fm^gfomtfi ' - r r. •?"TW&^.7^"T**'""'™w«»-=i^wiw^.sw_n__Mcarefully all mmiillnL attached Please resubmit the necessary plans and/of fpecificWonsrvvmYehanges "clouded", to this office for review and approval Conditions: Cond CON0003115 [MET] ** APPROVED THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW Entry 10/22/2008 By cwong Action AP Accutech Engineering Systems Inc Phone (858) 874-6768 Ext 111 5575 Magnetron Blvd Suite H Fax (858)8746912 San Diego CA 92111 Email info<§?accutechengineenng corr STRUCTURAL CALCULATIONS PACIFIC CNC ROOF EQUIPMENT 2702 GATEWAY RD., CARLSBAD, CA 92008 CLIENT LAI IA1NA ARCHITECTS ATTN TREVIN SCHALL 255 GST #129 SAN DIEGO, CA 92101 TARI.F OF CONTENTS Introduction Calculations References Sheets 1.1 Sheets CA 1 - CAS Sheets R1-R4 o October 7, 2008 Project Rcf: 083060-2 NEERING SYSTEMS INC PACIFIC CNC AUTHOR SHEET I CHECKED BY OF _ DATE |0 858 • 874*6768 "VH^T -p>f Op THt: TUT y^DDEp CNC AUTHOR _JV±L_ CHECKED BY SHEET ' OF DATE C/M 858 « 874*6768I Eft (/-if (HE KO" 6 LO^)L i- 05 F (if) ^ i.o 15 - > o - 3 -S pj SPS \ o 831 H?3 'T \\\ . . •?• - H" - \3 -S-l )3 <-, S-)-7fc'e i s i- i \ 13 £-| j Contermmous 48 States 2006 International Building Code Zip Code = 92008 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B - Fa = 1 0 ,Fv = 1 0 Data are based on a 0 01 deg grid spacing Period Centroid Sa (sec) (g) 02 1 251 (Ss, Site Class B) 10 0472 (S1, Site Class B) Period Maximum Sa (sec) (g) 02 1 360 (Ss, Site Class B) 10 0514 (S1, Site Class B) Period Minimum Sa (sec) (g) 02 1 075 (Ss, Site Class B) INC. AUTHOR CHECKED BY CA3 SHEET i. OF DATE: iohg 858 « 874*6761 PROJECT PACIFIC IUDF ff = f Wo H CC7C R/iAr5M A-ror»M DI \/n . 01 IITC u . e AM nicr^o r>Ano^^^JOB NO AUTHOR CHECKED BY SHEET OF DATE l%S" 858 « 874*6768 rfu'i* W r M" "i *<*"1 il e 2V" a c 3'Lr 1, L ,1 Iki. X no T^ ekv. 'k - 6.8 C5INEERING SYSTEMS INC. PROJECT PACIFIC AUTHOR CHECKED BY SHEET OF DATE CAS 858 » 374*6768 L/S'< .?i™ Yk : | OTTO f\r : is o UO - H 4- i \-VKx f r n PL =LL = \^ T Vvzj-f o-f JL.T°K€ 4, L - J,"T L i 3fL 0 1S)|<3S*> Q "i^^L 4 - o t in' X A .t r in "> •/^ -zr',^ > A^ .-. ok JOB NO 333495-YTG-B-0807 Weights and Dimensions BHX AND BHZ Unit Weights Unit 4 Point Load Weight FRONT OF UNIT CENTER OF GRAVITY Size (Tons) 024 (20) 030 (25) 036 (30) 042 (35) 048 (40) 060 (50) Model BHZ BHX BHZ BHZ BHX BHZ BHZ BHX BHZ BHX Weight (Ibs ) Shipping 360 385 355 395 405 445 490 445 500 465 Operating 355 380 350 390 400 440 485 440 495 460 Center of Gravity X 2225 2225 2225 2225 21 75 2225 2225 22 2225 22 Y 25 25 25 25 2425 25 25 26 25 2625 4 Point Load Location (Ibs ) A 96 103 96 106 108 120 132 126 135 133 B 84 90 84 92 90 104 115 107 117 113 C 81 87 81 89 92 101 111 95 113 99 D 93 100 93 102 110 115 127 112 130 116 Unit Accessory Weights Unit Accessory Add Economizer Add Electric Heat' Model All BHX, BHZ Weight (Ibs ) Shipping 45 13 Operating 40 12 1 Weight given is for the maximum heater size available (25 kW) Unitary Products Group 49 333495-YTG-B-0807 Heat Pump Unit Dimensions HIGH VOLTAGE CONN 7/8" DIA KNOCKOUT HIGH VOLTAGE CONN 1-31/32" DIA KNOCKOUT LOW VOLTAGE CONN 7/8" DIA KNOCKOUT SIDE SUPPLY AIR OPENING SIDE RETURN AIR OPENING FRONT COMPRESSOR SERVICE ACCESS COMPARTMENT PANEL REFRIGERANT CONNECTIONS ELECTRICAL/FILTER SERVICE ACCESS COMPARTMENT PANEL HIGH VOLTAGE CONN 1-23/64" DIA KNOCKOUT •4-1/2 . UNIT CONDENSATE CONNECTION 3/4" NPTI (TRAP REQUIRED) Heat Pump Unit Dimensions Unit Size 024, 036 0421, 048, 060 Dimensions "A" 33-1/2 41-1/2 1 BHZ Models Heat Pump Unit Clearances Direction Top1 Front Rear Distance (in) 36 12 0 Direction Right Left Bottom2 3 Distance (in) 24 24 0 1 Units must be installed outdoors Over hanging structure or shrubs should not obscure condenser air discharge outlet 2 Units may be installed on combustable floors made from wood or class A, B or C roof covenng materials 3 Minimum Clearance of 1 inch all sides of supply air duct for the first 3 foot of duct for 20 & 25 kW , zero inches there after For all other heaters, zero inch clearance all sides for entire length of duct Note For units applied with a roof curb, the minimum clearance may be reduced from 1 inch to 1/2 inch between combustible roof curb material and this supply air duct 50 Unitary Products Group AU IDEAS DESIGNS PLANS AND SPECIFICATIONS AND OTHER PROJECT DOCUMENTS INCLUDING All DOCUMENTS ON El£CTRONlC MEDIA ARE THE PROPERTY OF IAHAINA ARCHITECTS AND UAr NOT BE REPRODUCtD OR USED WITHOl/T THE WRfTTIN PERMISSION OF LAHAINA ARCHITECTSSop 25 2008 920am Ttovln j C \Trovln\l atialnn Archil eel s\ProJocis\20 OB LahaJn«\2008050 Pacific CNC (Building F)\CNC-A2 0 dwg LayoulNama A2 2 I 0 ooTl T) T> f 0 -© 0©0©0 3, 35 5t E5"1 BB PS 8Tl PACIFIC CNC - MACHINE CO, 2702 GATEWAY ROAD CARLSBAD, CALIFORNIA 92008 S2S ° sfiS * »£* m |fl N jj O ^ « m e —-e 6HE5T TITLB BUILDING P TI (P BRESSI RANCH LOTS 33-36 SPECTRUMFLEX LLC CARLSBAD CA 92008 SmithComultingArchitects 12220 BOmnoReal Suite 200 San Diego CA 92130 (85B) 793 -4777 (858) 793 4787 Fax KOHLER Features • Vitreous china • 12" (30 5 cm) rough-in • Ingenium® flushing system • 2" (5 1 cm) glazed trapway • Includes polished chrome trip lever • Less seat and supply . 16gpf(6lpf) • Elongated bowl • 16-1/2" (41 9 cm) high bowl is ADA compliant when an open front seat is installed • Available with lnsuliner& insulated tank lining (-U), tank cover locks (-T), or bedpan lugs (-L) • 11-1/8' (28 3 cm) x 9-1/2" (24 1 cm) water area . 29" (73 7 cm) x 19-5/8" (49 8 cm) x 30' (76 2 cm) Codes/Standards Applicable Specified model meets or exceeds the following . ADA . ASMEA112192 . IAPMO/UPC • CSA International . CSAB45 . Energy Policy Act of 1992 Specified Model HIGHLINE, COMFORT HEIGHTiM COMBINATION ELONGATED TOILET K-3427 Colors/Finishes . 0 White • Other Refer to Price Book for additional colors/finishes Accessories: • CP Polished Chrome • PB Polished Brass • Other Refer to Price Book for additional colors/finishes Model K-3427 K-3427-RA K-3427-U K-3427-UR K-3427-UT K-3427-T K-3427-TR K-4274-L / K-4620 K-4274-L/K-4620-RA Description Combination elongated toilet Combination elongated toilet Insuliner insulated tank lining Insulmer insulated tank lining Insuliner insulated tank lining and tank cover locks Tank cover locks Tank cover locks Bedpan lugs Bedpan lugs Trip Lever left-hand right-hand left-hand right-hand left-hand left-hand right-hand left-hand right-hand Colors/Finishes DO ao ao ao ao ao ao ao ao a Other a Other a Other a Other a Other a Other a Other a Other a Other Product Specification: The combination toilet with elongated bowl shall be made of vitreous china Toilet shall be 29" (73 7 cm) in length, 19-5/8" (49 8 cm) in width, and 30" (76 2 cm) in height with an 11-1/8" (28 3 cm) x 9-1/2" (24 1 cm) water area Toilet shall feature a 12" (30 5 cm) rough-in, 2" (5 1 cm) glazed trapway, polished chrome trip lever, and 1 6 gpf (6 Ipf) with Ingenium flushing system Toilet shall feature a 16-1/2" (41 9cm) high bowl which is ADA compliant when an open front seat is installed Toilet shall be available with an Insuliner insulated tank lining (-U), tank cover locks (-T), or bedpan lugs (-L) Toilet shall be less seat and supply Toilet shall be Kohler Model K- - - or K-4274-L- /K-4620- , or K-4274-L- /K-4620-RA- Page 1 of 2 114872-4-BD USA 1-800-4-KOHLER Canada 1-800-964-5590 kohlercom HIGHLINE© Recommended Accessories K-4650 K-4664 K-7637 LustraTM elongated open front toilet seat - for ADA compliant installation BreviaTM elongated closed front toilet seat Angle supply with stop Q CP Optional Accessories K-9404-L K-9404-R Left-hand trip lever - non-CP Q PB Right-hand trip lever - non-CP Q PB Q 0 Q Other Q 0 Q Other Q Other Q Other Q Other Technical Information Fixture Configuration Water per flush Passageway Water area Water depth from rim Seat post hole centers two-piece, elongated 1 6 gal (6 L) 2" (5 1 cm) 11-1/8" (28 3 cm) x 9-1/2" (24 1 cm) 6" (15 2 cm) 5-1/2" (14 cm) Included components Bowl Tank L- less bedpan lugs OR - with bedpan lugs - left-hand trip lever OR - right-hand trip lever Tank cover Trip lever K-4274 K-4274-L K-4620 K-4620-RA 84591 K-9404 Installation Notes Install this product according to the installation guide 1" (2 5 cm) 3-1/4" (8 3 cm) 29" (73 7 cm) 15" (38 1 cm) 30" (76 2 cm 16-1/2" (41 9 cm) -5/8" (49 8 cm) 12" (30 5 cm) £ Of Outlet Front Of Bowl 16" (40 6 cm) 5-5/8" (143cm) 10" (25 4 cm) / 5-1/8" (13 cm) 3/8" NPT Supply Product Diagram 9-5/8" (24 4 cm) HIGHLINE® COMFORT HEIGHTtM COMBINATION ELONGATED TOILET Page 2 of 2 114872-4-BD THE BOLD LOOKKOHILER TITLE 24 REPORT Title 24 Report for: Pacific CMC Machine Co 2702 Gateway Rd Carlsbad, CA 92008 Project Designer: Lahiana Architects 255 G Street #129 San Diego, CA92101 858-357-5509 Report Prepared By: Mark E Richards Emery Mechanical Engineering 6653 Cowles Mtn Blvd San Diego, CA92119 (619)464-5348 Job Number: 0834 Date: 9/17/2008 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards This program developed by EnergySoft LLC - www energysoft com EnergyPro 4 4 by EnergySoft Job Number 0834 User Number 5944 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form ENV-MM Envelope Mandatory Measures 12 Form MECH-MM Mechanical Mandatory Measures 13 HVAC System Heating and Cooling Loads Summary 15 Room Load Summary 16 EnergyPro 4 4 by EnergySoft Job Number 0834 User Numbsr 5944 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF-1 PROJECT NAME Pacific CNC Machine Co |DATE i ! 9/17/2008 ! PROJECT ADDRESS2702 Gateway Rd Carlsbad PRINCIPAL DESIGNER - ENVELOPE [ Lahuana Architects IDOCUMENTATION AUTHORi Emery Mechanical Engineering TELEPHONE 858-357-5509 —j Building Perm U # 'TELEPHONE j (619)464-5348 Checked tiy/Date Enforeeme.'il Ane-'icy Use [GENERAL INFORMATION I DATE OF PLANS BUILDING CONDITIONED FLOOR AREA BUILDING TYPE 9/10/081 iXl NONRESIDENTIAL 1,150SqFt ICUMATE ZONE 'PHASE OF CONSTRUCTION NEW CONSTRUCTION I i HIGH RISE RESIDENTIAL , 1 ADDITION "I HOTEUMOTEL GUEST ROOM JXi EXISTING + ADDITION/ALTERATION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and € of the California Code of Regulations This certificate applies only to a Building using the performance compliance approach JThe documentation preparer hereby certifies that the documentation is accuratfr and^cynplete DOCUMENTATION AUTHOR JSIGNATURE/J _ Mark E_ Richards I. _ I/ The Pnncipal Designer hereby certrfys that the proposed building design represented in this set of construction document;, is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with permit application The proposed building as designed meets the energy efficiency requirements contained in sections 110,116, through 118, and 140,142, 143 or 149 of Title 24, Part 6 ENV LTG MJCH "yf^ 1 I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions C ode to sign this document as the person responsible for its preparation, and that I arn licensed in the State of California as a civil engineer mechanical engineer, electncal engineer, or I am a licensed architect | j 2 I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section — 5537 2 or 6737 3 to sign this document as the person responsible for its preparation, and that 1 am a licensed contractor performing this work ! j 3 I affirm that 1 am eligible under Division 3 of the Business and Professions Code to sign this document ' • because it pertains to a structure or type of work descnbed as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737 1 (These sections of the Business and Professions Code are pnnted in full in the Non residential Manual) this' —\ ENVELOPE COMPLIANCE I Indicate location on plans of Note Block for Mandatory Measures [PRINCIPAL ENVELOPE DESIGNER - NAME Lahiana Architects Required Forms ' ENV-1 " fslGMATURE LJC NO DATE LIGHTING COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures i Lighting Compliance Not In The Scope Of Requ,red Forms PRINCIPAL LIGHTING DESIGNER - NAME SIGNATURE LIC NO IDATE IMECHANICAL COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures j { Requ PRINCIPAL MECHANICAL DESIGNER - NAME Emery Mechanical Engineering MECji-1. MECH-2. MECH-3. MECH-5 ) ; DATr-r? i- ! " Run Initiation Time: 09/17/08 17 OS 25 Run Code 1221696325 EnwgyPro 1 4 by EnergySoft User Number 5944 Job Number 0834 Pagi 3 at 16 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 IPERF-^ PROJECT NAME Pacific CMC Machine Co ;DATE I 9/17/2008 ANNUAL TDV ENERGY USE SUMMARY (kBtu/sqft-yr) Standard ENERGY COMPONENT Design < « 1 r F [ L F F Space Heating 10 68 Space Cooling 105 97 ndoor Fans 64 17 Heat Rejection o oo 3umps & Misc o oo Domestic Hot Water 17 13 .ighting 72 80 Receptacle 83 94 3rocess o oo TOTALS 354 69 Percent better than Standard Proposed Compliance Design Margin 623 6930 4057 I 000 : 000 1896 | 7280 8394 000 291 81 445 3666 2360 000 000 I -1 83 000 000 000 j 6288 177% ( 177% exclud ••;•*! Standard :•• • Proposed • • . Space Hea'Sno . Speco Coring . Indoor Fans Heal Reject-on Pumps fi Mice OHW Lrghanjj Receptacle Pra.« i3 • ; ,j ^s^^*M8^ati j ii S»«SIP|!I j ••ra^Wb-ttHNViowimawMii ; •,..»:,;«S«««!,3.I3«^::aK«B[:,::.BBaSS::,a«W,] i! 0 10 20 30 40 50 60 70 80 90 100 j E kBtu/sqft yr } ing process) BUILDING COMPLIES GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of Zones (N)Odeg Conditioned Floor Area 1 Unconditioned Floor Area 1 Conditioned 2 Fuel Type Footprint Area 1,150 sqft 4,730 sqft ; 1,220 sqft | Natural Gas ' Orientation Gross Area Front Elevation Left Elevation Rear Elevation Right Elevation Total Roof (N) 345 (E) 50 (S) ' 0 (W) 515 sqft sqft sqft sqft 910 sqft i 1 ,220sqft Glazina Area Glazing Ratio 179 32 0 161 372 sqft 51 9% sqft ! 64 0% sqft 0 0% sqft 31 3% sqft 40 9%j 0 1 sqft 00% Standard Proposed Lighting Power Density 1 Prescriptive Env Heat Loss f Prescriptive Env Heat Gain 35,< 200 w/sqft , 1 200 313-Btu/h 537 D89JBtu/h-F 30,117 W/sqft Btu/h Btu/h-F Remarks Run Initiation Time 09/17/08 17 05 25 Run Code 1221696325 EnergyPro 4 4 by EnergySoft User Number 5944 Job Number 0834 Pace 4 of 16 PERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF-1 PROJECT NAME DATE Pacific CMC Machine Co 9/1 7/2008 ZONE INFORMATION System Name ! AC-1 Zone Name Office Occupancy Type Office i Warehouse Industrial Work High Bay I | Floor Area (sqft ) 1,150 Inst LPD |_(W/sf)1 *1 200 4,730i *1 100 Notes 1 See LTG-2-C 2 See LTG-4-C 3 See LTG-5-C 4 See LTG-6-C(items marked with asterisk see LTG-2 -C by others) (by others) Ctrl Credits (W/sf)2 Allowed LPD Area I Tailored (W/sf)3 (WAsf)4 | " - •• Proc Loads (W/sf) Items above require special documentation [EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist These items require special written justification and documentation, and special verification to be used with the performance approach The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted The HVAC System "York B1HZ048" includes an Economizer This system has a cooling output < 75,000 Btuh or a supply cfm < 2500 The HVAC System "York B1HZ048 Premium Eft" 0 60 BMP Supply Fan Motor has been specified The Zone "Office" has a North/East/South Display Perimeter Credit of 32 ft jThe Roof "Roof has been designated as an alteration, however the Roof Surface is NOT being replaced The Roof "Roof has been designated as an alteration, however the Roof Surface is NOT being replaced The Roof "Roof has been designated as an alteration, however the Roof Surface is NOT being replaced The Roof "Roof has been designated as an alteration, however the Roof Surface is NOT being replaced The Roof "Roof has been designated as an alteration, however the Roof Surface is NOT being replaced The exceptional features listed in this performance approach application have specifically been reviewed Adequate written justification and documentation for their use have been provided by the applicant Authorized Signature or Stamp I Run Initiation Time 09/17/08 17 | EnergyPro 4 4 by EnergySoft User Number 5944 05 25 Run Code 1221696325 Job Number 0834 Page 5 of 16 CERTIFICATE OF COMPLIANCE ENV-1-C PROJECT NAME Pacific CMC Machine Co DATE 9/17/2008 OPAQUE SURFACES # ~r\hn^ 5 6 7 8 Qy~w11 12 13 14 15 Surface _Type_- Demising Wall Roof Wall Roof Demising Roof Wall Demising Roof Wall Wall Roof Wall Wall Area _. _225r 8a 220 92 ' 220 300 170 45 21C 340 U-Fac Insulation Cav Cont 0102 R-13 01781 None 0048 0178 0048 0102 _R-!9 None1 R-19 R-13 0 048 R-19 0178 0102 None R-13 0048 R-19 90 0 178 129J 0178 270 18 76 None None 0048 R-19 0 178 None 01 78 1 "None R-00 R-50 R-00r-R-50 R-00 _MO, ^R-00 R-50 R-00 R-00 R-50 R-50 R-00 R-50 R-50 Act Azm 0 315 0 315 0 U_° Jo 315 l , 0 0 45 1315 0 135 ~~45 ' Tilt 90 90 _0_..J 906 ' 90 0 "^ 90 90 0 90 90 0 90 90 Cond* Status New Existing Altered Existing Altered New Altered Existing New Altered Existing Existing Altered Joint Appendix IV Reference Location / Comments 09-A3 : Office (faces Warehouse) 13-D5 01-A14(E=01-A11) Office Office 13-D5 Office 01-A14(E=01-A11) 09-A3 Office Office (faces Warehouse) 01-A14(E=01-A11) Office 13-D5 Office 09-A3 I Office (faces Warehouse) 01-A14(E=01-A11) :Office 13-D5 | Office 13-D5 ; Office 01-A14(E=01-A11) Existing !13-D5 Existing | Office Office 13-D5 .Office 'NEAR (New Existing Altered Removed) IFENESTRATION SURFACESnMore than or equal to 10 000 sq ft of site built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U factors from ._ Standards Table 116 A and B Certificate shall be filed in the contractor's project office during construction and in the building manager s office after construction #1 2 3 _J_l 5 Type Window Right (NW) Window Right (NW) Window Front (NE) [Window Right (NW) Window Left (SE) 6 Window Front (NE) l= Area 52 48 75 U-Fac1 1030 1 030 1 030 61 1 030 32! 1 030 104 1 030 NFRC NFRC NFRC NFRC NFRC NFRC I Ir SHGC2 031 031 Act Cond Azm j Stat Glazing Type Location^ Comments NFRC 315| Existing , PPG Solarcool Canbia 'Office NFRC 031|NFRC 315; Existing | PPG Solarcool Canbia 45 Existing PPG Solarcool Canbia 031INFRC, 315 Existing 031 NFRC I 135, Existing 031|NFRCi 45 i Office Office PPG Solarcool Canbia Office PPG Solarcool Canbia Office Existing PPG Solarcool Canbia Office ! 1 11 l ! 1 (1)U factor Type 116 A Default Table from Standards Table Nl 1 Default Table from the ACM Manual Appendix NFRC Labeled value(2) SHGC Type 116-S Default Table from Standards COG Center of Glass NFRC Labeled Value EXTERIOR SHADING # ! Window Overhang Exterior Shade Type iSHGC, Hgt Wd | Len Hat LExt RExt Left Fin I Right Fin Dist Len Hqt ' Dist Len Hat 1 I None I 0 76 | I ' I 2 3 jj 5 6 L_ E None ' 0 76 ! ; None 0 76 j Ii None 0 76 ! I None : 0 76 8040 80 01 80 80 None J076J80130 80018080 : ! I I | ' | | '!: | I MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES I The proposed building is in climate zones 2 through 15 and contains an enclosed space with floor area greater than 25 000 ft2 a ceiling height greater than 15 feet and an LPD for general I : lighting of at least 0 5 W/ft2 See Section 143(c) If this box is checked ENV-4-C must be filled out when submitting under the Prescriptive Compliance Approach I Run Initiation Time 09/17/08 17 ; EnergyPro 4 4 by EnergySoft User Number 5944 05 25 Run Code 1221696325 Job Number 0834 Page 6 of 16 CERTIFICATE OF COMPLIANCE MECH-1-C IPROJECT NAME Pacific CNC Machine Co DATE 9/17/2008 Designer This form is CO be used by the designer and attached to the plans Listed below are all the acceptance tests for mechanical systems The designer is required to check the boxes by all acceptance tests that apply and list all equipment that requires an acceptance test If all equipment of a certain type requires a test, list the equipment description and the number of systems to be tested in parentheses The NJ number designates the Secton in the Appendix of the Nonresidential ACM Manual that describes the test Also indicate the person responsible for performing the tests (i e the installing contractor, design professional or an agent selected by the owner) Since this form will be part of the plans completion of this section will allow the responsible party to budget for the scope of work appropriately Building Departments1 SYSTEM ACCEPTANCE Before an occupancy permit is granted for a newly constructed building or space, or a new space-conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance In addition a Certificate of Acceptance, MECH-1-A Form shall be submitted to the building department that certifies plans, specifications, installation certificates and operating and maintenance information meet the requirements of Secton 10-103(b) and Trtle 24 Part 6 {STATEMENT OF COMPLIANCE I iMECH-2-A. Ventilation System Acceptance Document -Vanable Air Volume Systems Outdoor Air Acceptance -Constant Air Volume Systems Outdoor Air Acceptance Equipment requmng acceptance testing .. . . '• Test required on atl New systems both ttevf Construction and Retrofit i 2J.MECH-3-A. Packaged HVAC Systems Acceptance Document r^~rt- P-, Test required on eU New systems both New Construction and Retrofit ^JMECH-4-A Air-Side Economizer Acceptance Document Equipment requmng acceptance testing I Test required on alt New systems both New Construction and Retrofit Units with oconomjze/s that are installed at the factory and certified wrth the ! commission do nol require equipment testing but do reqj-m construction inspection ! MECH-5-A. Air Distribution Acceptance Document Equipment requiring acceptance testing Tins test ruquirad Htlre uru serves 5 000l\2 o! space or'ess and 25% or more ottha ducts are in nonconditioned orsemicenditioned space tika an attic- New systems that meet trie above requirements Retrofit systems thai meet the above requirements and ofttier extend ducts, real&ce ducts or replace the packager} urtfi. i MECH-6-A Demand Control Ventilation Acceptance Document Equipment requmng acceptance testing _ _ _ _ _ AH new DCV controls installed on new or existing packaged systems must be tested MECH-7-A. Supply Fan Vanable Flow Control Acceptance Document Equipment requiring acceptance testing _ Alt new VAVtOfi volume controls installed on new or existing systems must be tested '•• MECH-8-A -Hydronic System Control Acceptance Document -Vanable Flow Controls Applieslocbtlledand'hotwatersystem -Automatic I SOlation Controls Applies to new barters arid chillers and t -Supply Water Temperature Reset Controls Applies to new constant How chitted and hot water systems the! have a design capacity greater then of equal to 5OO 000 Btulhr -Water-loop Heat Pump Controls Applas to all new waterloop heat pump systems where the ombrnetl loop pumps ere greater than 5 tip -Vanable Frequency ContTOlS Applies to ell new distribution pumps on new vanable How chiSed, hydronic hael pump Of conoerrset water systems where the pumps motors are greater than 5 rip Equipment requiring acceptance testing _ j EnergyPro44 byEnergySoft User Number 5944 Job Number 0834 Page 7 of 16 AIR SYSTEM REQUIREMENTS Parti of 2 MECH-2-C PROJECT NAME Pacific CMC Machine Co iDATE 9/1772008 ISYSTEM FEATURES I ITEM OR SYSTEM TAG(S) AC Number of Systems T-24 MANDATORY MEASURES Section AIR SYSTEMS, Central or Single Zone ;-i : Reference on Plans or Specification 1 Heating Equipment Efficiency Cooling Equipment Efficiency Heat Pump Thermostat Furnace Controls Natural Ventilation Minimum Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation 112(a)7 70 HSPF I ! 112(a) : 130 SEER/ 10 6 HER , 112(b) 112(c) 115(a) 121(b) 121(b) 121(c) 121(c) 121(c), 122(e) 122(e) 122(f) 122(g) 123 124 Yes n/a No 172cfm No No Programmable Switch No Setback Required Auto n/a R-42 i PRESCRIPTIVE MEASURES Calculated Heating Capacity x 1 43 2 Proposed Heating Capacity 2 Calculated Sensible Cooling Capacity x 1 21* 1144 (a & b) Proposed Sensible Cooling Capacity 2 Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heating Air Supply Reset Cooling Air Supply Reset 144 (a &b) 144Ja&b) 144 (a &b) 144 (a &b) 144(c) 144(c) 144(c) 144(d) 144(e) 144(f) 144(f) 144(k) n/a 34,807 btuh n/a 37,307 btuh Constant Volume No No Fixed Temp (Non-lnteg) Constant Temp Constant Temp YesDuct Sealing for Prescriptive Compliance 1 For each central and single zone air systems (or group of similar units) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented If a requirement is not applicable put "N/A" in the column 2 Not required for hydronic heating and cooling Either enter a value here or put in reference ot plans and specificatons per footnote 1 3 Enter Yes if System is Constant Volume, Single Zone Serves < 5 000 sqft Has > 25% duct in unconditioned space Duct sealing is required for Prescriptive Compliance see PERF-1 for performance method duct sealing requirements NOTES TO FIELD - For Buildma Department Use Onlv Run Initiation Time 09/17/08170525 EnergyPro 4 4 by EnergySoft User Number 5944 I Run Code 1221696325 Job Number 0834 Page 8 of 16 WATER SIDE SYSTEM REQUIREMENTS Part 2 of 2 MECH-2-C PROJECT NAME Pacific CMC Machine Co DATE 9/1772008 ISYSTEM FEATURES ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Equipment Efficiency Pipe Insulation T-24 Section 112(a) 123 2 WATER SIDE SYSTEMS Chillers, Towers, Boilers, Hydromc Loops | i Reference on Plans or Specification1 i | PRESCRIPTIVE MEASURES Calculated Capacity Proposed Capacity Tower Fan Controls Tower Flow Controls Variable Flow System Design Chiller and Boiler Isolation CHW and HHW Reset Controls WLHP Isolation Valves |144(a&b) 144 (a &b) 144 (h) 144Jhl___ 144 Q) J.44.0L VSD on CHW, CW & WLHP Pumps > 5 HP , DP Sensor Location |_t< Service Hot Water, Pool Heating DHW Heater 4 I i 1 For each chiller, cooling tower boiler and hydronic loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented If a requirement is not applicable put "N/A" in the column 2 Water side systems include wet side system using other liquids such as glycol or brine ITEM OR SYSTEM TAG(S) Number of Systems MANDATORY MEASURES Water Heater Certification Water Heater Efficiency Service Water Heating Installation Pool and Spa Efficiency and Control Pool and Spa Installation Pool Heater - No Pilot Light Spa Heater - No Pilot Light Reference on Plans or Specification1 113 (a)Instahot SR-20L 85% n/a n/a n/a n/a 1 For each water heater pool heat and domestic water loop (or groups of similar equipment) fill in the reference to sheet number and/or specification section and paragraph number where the required features are documented If a requirement is not applicable, put "N/A" ins the column INOTES TO FIELD - For Buildma Department Use Only I Run Initiation Time 09/17/08170525 EnergyPro 4 4 by EnergySoft User Number 5944 Run Code 1221696325 Job Number 0834 Page 9 of 16 MECHANICAL VENTILATION MECH-3-C 'PROJECT NAME Pacific CMC Machine Co3 CO DATE 9/17/2008 MECHANICAL VENTILATION (Section 121(b)2) AREA BASIS A B C ZONE/SYSTEM Office ConditionArea(SF)CFMperSquare Foot1,150 015 AC-1 D X fr g to "n 172 PRE LIMr ESCRIPTIVE REHEAT FATION (Section 144(d)) OCCUPANCY BASIS : . VAV MINIMUM E Number ofPeoplep •D ® -O O 0*3 G Mm CFMby Occupant(ExF)Total H REQ'D V AMax of(DorG)172 172 I of?•n ~ <n 172 172 I J °P 0"> o ^ O T3 <2—(a ... K I L O i? 1°Max ofColumns H, J,K or 300 CFMM o 3 5 = _j N Transfer Air~| ^ C Minimum ventilation rate per Section 121 Table 121 A E Eased on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load for egress purposes for spaces without fixed seating H Required Ventilation Air (REQ D V A ) is the larger of the ventilation rates calculated on and AREA or OCCUPANCY BASIS (column D or G) 1 '. Must be greater than or equal to H or use Transfer Atr (column N) to make up the difference J : Design fan supply cfm (Fan CFM) x 30% or K (Condition area (ft sq ) x 04 cfm/ft sq or L | Maximum of Columns H J K or 300 cfm M This must be less than or equal to Column L and greater that or equal to the sum of Columns H t N N Transfer air must be provided where the Required Ventilation Air (column 1) is greater than the Design Minimum Air (column M) Where required, transfer air must be greater than 01 equal to the difference between the Required Ventilation Air (column 1) and the Design Minimum Air (column M) column H M I EnergyPro 4 4 by EnergySoft User Number 5944 Job Number 0834 Page lOof 16 MECHANICAL EQUIPMENT DETAILS PROJECT NAME Pacific CMC Machine Co Part 1 of 2 c MECH-5-C )ATE 9/1 7/2008 ICHILLER AND TOWER SUMMARY Equipment Name i i Equipment Typei i • i Qty Efficiency Tons PUMPS Tot Qty JGPM Motor Drive BMP Eff Eff i i Pump Control DHW / BOILER SUMMARY { System Name ilnstahot SR-20L System Type Instant Elec Distribution Type No Pipe Insulation Qty Rated Input 4J 14,500 i Fnernu Vol (Gals ) 0 Condition Factor Status or RE New 0 84 Standby TANK Loss or E Pilot R-\ n/a i I | NSUL Kt /al n/a MULTI-FAMILY CENTRAL WATER HEATING DETAILS Hot Water Pump Control #HP Type Hot Water Piping Length (ft) In Plenum Outside Buried Add 1/2" Insulation CENTRAL SYSTEM RATINGS System Name YorkB1HZ048 System Type Packaged DX Qty 1 HEATING I COOLING Output 45,500 Aux kW 00 ! Eff Output 770HSPF 47,800 Efficiency 130SEER/106EER Condition Status New Economizer Type Fixed Temp (Non-lntec [CENTRAL SYSTEM FAN SUMMARY System Name YorkB1HZ048 Fan Type Constant Volume i SUPPL1 Motor Location Draw-Through CFM 1,600 1 f FAN BHP 060 Motor Eff 80 0% Drive Eff 1000% ! i I RETURN FAN CFM none BHP i i Motor Eff Drive Eff Run Initiation Time 09/17/08 17 EnergyPro 4 4 by EnergySoft User Number 5944 05 25 Run Code 1221696325 Job Number 0834 Page 11 of 16 ENVELOPE MANDATORY MEASURES ENV-MM PROJECT NAME i Pacific CNC Machine Co DATE 9/1772008 DESCRIPTION X| § 118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3 | | § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2 |Xl § 117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstnpped or otherwise sealed : | § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstnpped (except for unframed glass doors and fire doors) I | § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E of the Standards Manufactured fenestration products must be labeled for U-value according to NFRC procedures |X| §118(e) Demising Walls in Nonresidential Buildings The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R-value of no less than R-13 between framing members Designer Enforcement J EnergyPro 4 4 by EnergySoft User Number 5944 Job Number 0834 Page 12 of 16 MECHANICAL MANDATORY MEASURES Parti of2 MECH-MM PROJECT NAME i Pacific CMC Machine Co DATE 9/17/2008 r c n DESCRIPTION Designer E 1 Equipment and Systems Efficiencies §1 11 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard §M5(a) Fan type central furnaces shall not have a pilot light §123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123 §124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of the 2001 CMC Standards Controls §!22(e) Each space conditioning system shall be installed with one of the following §l22(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off-hours for up to 4 hours The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted, or { ] §!22(e)1B An occupancy sensor to control the operating period of the system, or j | §122(e)lC A 4-hour timer that can be manually operated to control the operating period of the system j | §122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpomt [_ | §!22(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones Each zone shall not exceed 25,000 square feet, shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas, and shall be controlled by a time control device as described above [ I §122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone Where used to control heating, the control shall be adjustable down to 55 degrees F or lower For cooling, the control shall be adjustable up to 85 degrees F or higher Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum | j §122(c) Thermostats shall have numeric setpomts in degrees Fahrenheit (F) and adjustable setpomt stops accessible only to authorized personnel i_ I §t12(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone iner Enforcement EnergyPro 4 4 by EnergySoft User Number 5944 Job Number 0834 Pace 13 of 16 MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM PROJECT NAME Pacific CNC Machine Co DATE 9/1772008 Description Designer [Enforcement Ventilation j | §!21(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans • j §122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems I I §122(f) All gravity ventilating systems shall be provided with automatic or readily ' accessible manually operated dampers in all openings to the outside, except for combustion air openings I | §l21(f)1 Air Balancing The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989), or j | §121(f)2 Outside Air Certification The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system, or I I §121(f)3 Outside Air Measurement The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice, or | | §i21(f)4 Another method approved by the Commission Service Water Heating Systems | | §ll3(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required I| §113(c) Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F EnergyPro 4 4 by EnergySoft User Number 5944 Job Number 0834 Pags14of 16 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME Pacific CMC Machine Co SYSTEM NAME AC-1 ENGINEERING CHECKS Number of Systems i| Heating System Output per System 45,500 Total Output (Btuh) 45,500 Output (Btuh/sqft)396 Cooling System | Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sqft) Total Output (sqft/Ton) 47,800 47,800 40 41 6 288 7J Air System CFM per System Airflow (cfm) Airflow (cfm/sqft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sqft) 1,600 1,600 1 39 4017, 108| 015 Note values above given at ARI conditions SYSTEM LOAD COIL COOLING P CFM Sensible, L Total Room Loads 1,687 30,918 Return Vented Lighting 0 Return Air Ducts 1,546 Return Fan 0 Ventilation l 172 2,754 Supply Fan 0 ' Supply Air Ducts 1,546 TOTAL SYSTEM LOAD ' 36,763 DATE I 9/1772008 ! , FLOOR AREA1 1,150 EAK COILHTG PEAKJ atent CFM Sensible 3,199 667 25,184 1,259 0 2,088 172| 6,560 0 1,259 5.287 ' 34,263 IHVAC EQUIPMENT SELECTION j|YorkB1HZ048 37,307 Total Adjusted System Output ,.7 ,n7(Adjusted for Peak Design Conditions) I •«,•«" TIME OF SYSTEM PEAK Ji 8,514 I 34,807 I 8,514 34,807 jn 5pm; Jan 12am HEATING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heatmq Peak) 340°F 655°F « Outside Air Bj 172 cfm .f ' Heating i \ 693°F ^ _/ >•< if- •< ins n°F irwn°F f gv J * !} °u Coil Supply Fan 1600 cfm f ox pply Air Ducts" — | *1043°F ROOMS ,'00 °F I COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) 87 7 / 69 6 °F Outside Air 172 cfm i / 729/612°F /• -/<. jr— 745/620°F • 550/539°F 550/539°F 1 *» X* | ^ I ^B~"""~ 1 f?^ r~^ Q Cooling Coil Supply Fan k 1600 cfm •* c |j>' EnergyPro 4 4 by EnergySoft User Number 5944 Job Number 0834 Supply Air Ducts ^ — | 55 9 / 54 2 °F 532%RH | ROOMS | 72 0 / 60 9 °F I Page 15 of 16 ROOM LOAD SUMMARY PROJECT NAME Pacific CMC Machine Co SYSTEM NAME AC-1 DATE 9/17/2008 FLOOR AREA 1,150 IROOM LOAD SUMMARY ZONE NAME Office ROOM NAME I Mult Office 103 Office 102 Toilets/Break Office 106 Reception 101 j ROOM COOLING PEAK CFM 318 1: 310 1 1 1 111 406 583 SENSIBLE 5832 5,683 2,039 7,451 10,680 LATENT 612 612 473 751 750 — • PAGE TOTAL TOTAL COIL COOLING PEAK CFM 318 SENSIBLE 5,832 310 5,683 101 376 582 LATENT 612 612 1,853 473 6,889 10,660 751 751 COIL HTG PEAK CFM 10E 101 22 147 292 ii SENSIBLE 3,952 3,829 844 5,540 11,019 I ii i i! 1,687 30,918 1,687 30,918 3,199" 667 «,,«„. 667 25, 184 | 25,184 EnergyPro 4 4 by EnergySoft User Number 5944 Job Number 0834 Page 16 of 16 I ARCHITECTS 255 G Street #129 San Diego, CA 921 01 (858) 357-5509 Devon St Martin Pacific Building Group 9752 Aspen Creek Ct Suite 150 San Diego, Ca 92126 February 25,2009 Pacific CMC - 2702 Gateway Road Carlsbad, Ca 92008 Dear Devon St Martin: We spoke with our plumbing engineer and he does not have any issues with using a 2" line for the mop sink connection. If you have any questions or wish to discuss it further please do not he:srtate to contact us Sincerely, Trevin Schall - Architect/Partner Lahama Architects, LLP RECEIVED ARCHITECTS nnnn 25503^*129 OCT202008 San Diego, CA 92101 ^ _ _ _ (858)692-3835 CITY OF CARLSBAD PLANNING DEPT Date October 20, 2008 Plan Check No CB 08-1806 Project Address 2702 Gateway Road Project Name Pacific CMC - Machine Co -Tl Dear Chns Sexton I've added the site section on Sheet A9 0 (detail 2) per our discussion The parking information is on Sheet TS at the top left comer Thank you, Trevm Schall Lahama Architects, LLP (858) 692-3835 ARCHITECTS 255 G Street #129 San Diego, CA 92101 (858) 692-3835 Date October 10,2008 Plan Check No CB 08-1806 Project Address 2702 Gateway Road Project Name Pacific CNC - Machine Co -Tl Dear Chns Sexton 1 Parking breakdown is now shown on Site Plan - Sheet A1 0 There are 8 existing buildings on the site (all of which are currently vacant) The proposed tenant improvement we are doing for Pacific CNC will be the first occupied building in the entire complex 2 There is a new roof top unit and is shown on Roof Plan - Sheet A2 2 The top of the HVAC will be below the lowest parapet of the roof and will not be seen from adjacent properties (see parapet elevations on Roof Plan) Thank you, Trevm Schall Lahaina Architects, LLP (858) 692-3835 61 ID Check a License or Home Improvement Salesperson (HIS) Registration - Contractors Stat Page 1 of 1 Department of Consumer Affairs -^ ,} &OV Contractors State License Board Contractor's License Detail - License # 502376 /'A DISCLAIMER A license status check provides information taken from the CSLB license database Before relying on this information, you should be aware of the following limitations " CSLB complaint disclosure is restricted by law (B&P 7124 6) If this entity is subject to public complaint disclosure, a link for complaint disclosure will appear below Click on the link or button to obtain complaint and/or legal action information >' Per B&P 7071 17, only construction related civil judgments reported to the CSLB are disclosed v' Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration > Due to workload there may be relevant information that has not yet been entered onto the Board's license database License Number Business Information Entity Issue Date Expire Date License Status Extract Date 02/02/2009 Classifications Bonding 502376 PACIFIC BUILDING GROUP 9752 ASPEN CREEK COURT STE 150 SAN DIEGO, CA 92126 Business Phone Number (858) 552-0600 Corporation 12/04/1986 12/31/2010 This license is current and active All information below should be reviewed B C-2 C-9 DESCRIPTION GENERAL..BUILDING CONTRACTOR INSULATION AND ACOUSTICAL DRYWALL CONTRACTOR'S BOND This license filed Contractor's Bond number 1201808 in the amount of $12,500 with the bonding company IN SU R AflQE. COMPAN Y_ QFJTH E.WEST Effective Date 01/01/2007 Contractor's Bonding History BOND OF QUALIFYING INDIVIDUAL 1 The Responsible Managing Officer (RMO) GREGORY ALLAN ROGERS certified that he/she owns 10 percent or more of the voting stock/equity of the corporation A bond of qualifying individual is not required Effective Date 12/04/1986 Workers' Compensation This license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number A1CW36840804 Effective Date 03/01/2008 Expire Date 03/01/2009 Workers Compensation History Personnel listed on this license (current or disassociated) are listed on other licenses C.ondi.tLOjTS_QiU_se | .Privacy Policy Copyright © 2009 State of California http //www2 cslb ca gov/OnlmeServices/CheckLicense/LicenseDetail asp 02/02/2009 ACORDm CERTIFICATE OF LIABILITY INSURANCE VUMW PRODUCER Lockton Companies, LLC-L Los Angeles 725 S Figueroa Street, 35th Fl CA License #OF 1 5767 Los Angeles CA 90017 (213)689-0065 INSURED pacific Building Group 1 062766 9752 Aspen Creek Court, Ste 1 50 San Diego CA 92 126 i DATE (MM/DD/YYYY) 4/15/2008 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW INSURERS AFFORDING COVERAGE INSURER A Old Republic General Ins Corporation INSURER B American Guarantee and Liab Ins Co INSURER C INSURER 0 INSURER E NAIC# 24139 26247 COVERAGES PACBU01 Q3 THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES AGGHEGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS INSR LTR A A B A ADD I NSRI TYPE OF INSURANCE GENERAL LIABILITY X "x" COMMERCIAL GENERAL LIABILITY 1 CLAIMS MADE |X | OCCUR $10,000 Deductible GEN L AGGREGATE LIMIT APPLIES PER3 POLICY nss ruoc AL X •••• X X X X TOMOBILE LIABILITY ANY AUTO ALL OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON-OWNED AUTOS $l,OOOCompDed $ 1,000 Coll Ded GARAGE LIABILITY 1 ANY AUTO EXCESS/UMBRELLA LIABILITY X] OCCUR | | CLAIMS MADE 1 I"™! UMBRELLA DEDUCTIBLE LJ FORM 1 RETENTION $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVEOFFICEFI/MEMBER EXCLUDED? If yes describe under "•• SPECIAL PROVISIONS below OTHER POLICY NUMBER A1CG36840802 A1CA36840802 NOT APPLICABLE AUC59 1894902 A1CW36840804 POLICY EFFECTIVEDATE (MM/DD/YY) 3/1/2008 3/1/2008 3/1/2008 3/1/2008 POLICY EXPIRATIONDATE (MM/DD/YY) 3/1/2009 3/1/2009 3/1/2009 3/1/2009 LIMITS EACH OCCURRENCE DAMAGE TO RENTEDPREMISES (Ea occurencei MED EXP (Any one person) PERSONAL & ADV INJURY GENERAL AGGREGATE PRODUCTS COMP/OPAGG COMBINED SINGLE LIMIT {Ea accident) BODILY INJURY(Per peraon) BODILY INJURY (Per accident) PROPERTY DAMAGE (Per accident) AUTO ONLY EA ACCIDENT OTHER THAN EA ACC AUTO ONLY AGQ EACH OCCURRENCE AGGREGATE Y 1 WCSTATU 1 lOTHA 1 TORY LIMITS 1 1 ER E L EACH ACCIDENT E L DISEASE EA EMPLOYEE EL DISEASE POLICY LIMIT $ 1,000.000 S 100,000 $ 5000 $ 1,000,000 S 2,000,000 $ 2,000,000 S 1,000,000 $ xxxxxxx S XXXXXXX * xxxxxxx $ xxxxxxx $ xxxxxxx $ xxxxxxx S 1.000.000 s 1.000.000 S XXXXXXX s xxxxxxx $ xxxxxxx S 1 000,000 $ 1,000,000 $ 1 000 000 CERTIFICATE HOLDER CANCELLATION 3626846 Evidence of Insurance SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL 30 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO DO SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR REPRESENTATIVES AUTHeRJffie*£f>BESENTATiye7> ,-2^-ia^r ^ <£•«**»^-W^£" f -^V***** ACORD 25 (2001/08) Forque»ttai«reg«i<lmgtlil»c««tlfc«» contort flu numter Iteud m On Product MdUfTitom nd tpcfUyttio cMlfcod* VACBUH1 © ACORD CORPORATION 1988 i Consumer Affiun State Of California CONTRACTORS STATE LICENSE BOARD -• ACTIVE LICENSE 502376 ^ CORP PACIFIC BUILDING GROUP M B C-2 C-9 U. 12/31/2008 THIS DOCUMENT HAS A TRUE DEFENSA™ WATERMARK AND VISIBLE FIBERS DISCERNIBLE FROM BOTH SIDES NOT TRANSFERABLE BUS NUMBER 1207435 DATE ISSUED 8/19/2008 SIC CODE 15 OWNER FIRM OR CORPORATION NAME BUSINESS NAME MAILING ADDRESS CITY AND STATE CITY OF CARLSBAD BUSINESS REGISTRATION CERTIFICATE POST IN CONSPICUOUS PLACE The person firm or corporation named Mow is granted Ihis business certificate pursuant to the provisions of the Oty eusuwss Lcenss Ordinances lo engage la carry on or conduct the business, trade catting profession exhibition or occupation described oelow Issuance of Ins certificate is not sn endorsement nor certification of compliance Mlh other ordinances or laws This license is issued without verification that the Icensee it subject to or exempt from licensing by the Stale of California BUSINESS LOCATION 9752 ASPEN CREEK CT STE 150 SIC DESCRIPTION Building Construction-General Building Contrac EXPIRATION DATE PACIFIC BUILDING GROUP PACIFIC BUILDING GROUP 9752 ASPEN CREEK CT STE 100 : SANDrEGO. CA 92126-1082 9/30/2009•cj\ AUG2 22 ^ KEEP FOR YOUR R BUSINESS TAX RE( BUS NO 120 DATE ISSUED 8/19/2008 08 070G BALANCE TAXES PAID IN ACCORDANCE \ BUSINESS TAX ORDINANCE CITY OF CARLSBA I 8U Q. I MU 2•oU4* 1Ci o aa ^ \ c £- ^ ^^•^ i_ r^v^^ P\L B*n ^\€r ^- 0-\ C0^- /7v ^ •^o^ ~c" ^» — r> ife do •S.^" "5" ^-2.O ^>o 0>«^S