Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2706 INVERNESS DR; ; CB163700; Permit
'4 - - 4 - --,T -- City of Carlsbad 1635 FaradayAv Carlsbad, CA 92008 -Print Date: 04/12/2017 Residential Permit • www.carlsbadca.gov Job Address: - 2706 Inverness Dr . Permit Type: - BLDG-Residential . Work Class: Addition Status: Parcel No: 2081124600 Lot U: Applied: Valuation: $231,488.92 Reference U: Issued: 46cci.ipancyGroup: Construction Type: Finaled: #DeIIing Units: Bathrooms: Inspector: - Bedrooms: Orig. Plan Check U: Plan Check U: Project Title:. Description MIDDLETON MAJOR REMODEL OF 1792 SF & 874 SF ADDITION Owner: Co-Applicant: 4, ..- TRUST MIDDLETON GLEN P&ROCIO LIVING LUX LANDSCAPE DESIGN INC TRUST 07-17-09 2706 Inverness Dr 1309 Vista Colina Dr -: ' . • CARLSBAD, CA 92010 San Marcos, CA 92078-1357 760-214-8880 Permit No: CB163700 Closed - Finaled 09/28/2016 01/11/2017 PBurn . BUILDING PERMIT FEE $2000+ $1,094.60 - 'ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMObEL . $66.00 '>GREEN BUILDING STANDARDS PLAN CHECK ' ,. $166.00 MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL $9200 PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL $182.00 SB1473 BUILDING STANDARDS FEE ' . $10.00 STRONG MOTION-RESIbENTIAL . $30.09 SWPPP INSPECTION FEE TIER 1- Medium $232.00 ..SWPPP PLAN REVIEW FEE TIER 1- MEDIUM $55.00 Total Fees: $1,927.69 Total Payments To Date: $1,927.69 Balance Due: . $0.00 S Please take NOTICE that approval of your project includes the "Irposition" of fees, dedications, reservations, or other exactions hereafter ., collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these - fe6s1exactins: If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the - protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review, set aside void or annul their 'imposition.. YOIJ are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this • - project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the - statute of limitation has previously otherwise expired. • -'- 4 "S I -, •• I - . 4- -. • . S., - • - IS 4•• -' •, 5 0 - - -- -S.-- ._•5, 5 -'S - • '• -. - -, -S.- . • 5p 5 - '• . . ..y .4.-,- •_5 .. . - S ••• -- 1 • IThE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: DPLANNING DENGINEERING DBUILDING DARE DHEALTH DHAZMATIAPCD I f.• Building Permit Application Plan Check No. 73 7 0 Est. Value I10 &7 4, City.of 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit 'b C I email: bulldlng©carlsbadca.gov ar'S a (i Date f I ic, ISWPPP 10 www.carisbadca.gov JOB ADDRESS - .. 2706 Inverness, Carlsbad, Ca. surrE./sPACE,/UNrr. APN - - CT/PROJECT U -. LOT U 1 PHASE # 1#OFUNrTS I #BEDROOMS U BATHROOMS I TENANT BUSINESS NAME CONSTR. TYPE I 0CC. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) , Remodel interior of home (kitchen, living room, dinning room) to an open floor plan, add new master suite approximately TIM. of total addition EXISTING USE - - PROPOSED USE GARAGE (SF) ,ATI0S (SF) DECKS (SF) FIREPLACE AIR CONDITIONING FIRE SPRINKLERS - YE# N(J YESONOE31 YESD NCO APPLICANT NAME Dominic Ramirez PROPERTY OWNER NAME Glen & Rocio Middleton Maly Mad ADDRESS ,.. . ., . P.O. Box 1441 ADDRESS 2706 Inverness - CITY ,. '. STATE ZIP San Marcos Ca 92079 Carlsbad Ca PHONE , U CITY STATE ZIP 7602148880 . FAX 8886689877 PHONE 6196189049 FAX EMAIL' - ' dominic@luxhomebuilder.com EMAIL middg@aol.com DESIGN PROFESSIONAL Marshall Booth CONTRACTOR BUS. NAME Lux ,..' .. ADDRESS - . 1107 S. Coast Hwy ADDRESS P.O. Box 1441 - CITY, STATE ZIP -. Oceanside .-. . Ca 92054 CITY STATE ZIP San Marcos Ca 92079-. PHONE . - 760,703 7996 , FAX - . . ' PHONE 888 668 9877 FAX 888 668 9877' EMAIL , mbooth@spacesrenewed.com EMAIL dominic@luxhomebuilder.com V . ' STATE LIC. U 931687--T TATE II CLASS 982871 B CITY BUS. LIC.# .. - 1242394; V - 'V (Sec. 7031,5 Business and Professions Code: Any City or County which requires a permit to construct, alter, Improve, demolish or repair any structure, prior to its issuance, also requires the applicant for Such permitto file a signed statement that he is licensed pursuant to the provisions of the Contractor's License LawfChapter 9, commending with Section 7000 of Division 3 of the . Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil øenalty of not more than five hundred dollars ($500)). Workers' Compensation Declaration: I hereby afftmr under penally of perjury one of tire following declarations: I have and will maintain a certificate of consent to self-insure for workers' compensaton as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I havó and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carder and policy V V ".number are: Insurance Co. _United specialty insurance Co. Policy No. 91557512016 Expiration Date 3.26.2017 sec ti on need not be completed it the permit is for one hundred dollars ($100) or less. Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In addition to the cost of compensation, damages as provided for I_I_3706 of the Labor code, Interest and attorney's fees, CONTRACTOR SIGNATURE ..- 0 AGENT DATE I hereby affirm that I am exempt from Contractor's License Law for the following reason: 9 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sate (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for safe. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). [J I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of.', property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). , V I ant exempt under Section V Business and Professions Code for this reason: V - U 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Yes [::]No V U V 2. I (have! have not) signed an application for a building permit for the proposed work. I have contracted with the f000wing person (firm) to provide the proposed construction (include name address! phone! contractors' license number): . I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name) address! phone! contractors' license number): . - 5. I will provide some of the work, butt have contracted (hired) the following persons to provide the work indicated (include name! address! phone! type of work): V , PROPERTY OWNER SIGNATURE , ' -. flAGENT DATE I Vt •fV ' -' - ,& ' 4. '_.'•'4• 4',,4. •,' .• .4Z• '.', O3WQe U (V]®L1. WOUDOUND 90000VO 001 Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration tdrm or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? CJ Yes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes 0 No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 Yes 0 No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 'D1OøL O(ZJØ - '. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (I) Civil Code). Lenders Name . Lender's Address . . I crelifythat I have read the application and statethatthe above Information is correct and that the lnfonnatlon on the plans lsactasate. I aeto comply wlth all City ordinances and State laws relating thbulldingconatneion. hereby iuthorize representative of the City of Cadebed to enter upon the above mentioned properly for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF GARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. -, OSHA An OSHA permit is required for excavations over 50' deep and demolition or construction of structures over 3storios in heisht EXPIRATION: Every permit issued by the Building Official under the provisions of this Code that expire by limitation and become nut and void lithe building or work authorized by such permit is not commenced within l8o days from the data ofsuch permit orf the building or work authorized by such permit is suspended orabandonedat any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). APPLICANVSSIGNATURE DATE .. oie ' 4. .. '' . ,':r ' -. - , - . - , . : . -.' : . t._ - ., I '.7 • 4'. - -. - , . .- - , ''.7",' _t ' . ,. S - . _"-.' - ,a .. 4. I l,/ '' '.v., ,.- .• . 4. * '.-. 7- _4.l. ' : - . •.., ,. - 7,.. •_,• .4 . . . . -' ., - - ..•; . . ' . 7 . 7. - -- , • ,.- - .. -. • _ "70 • I I _tt.• 4 - 7 - - - ' . 4 j 4*4 4.- - . .'. . , . . 7 . . . - - .• •I_t•,- .4,- •- , .. . - . , 1,.1_-"•......,,4' • '- ' '--• -' 5'' . -' -',' ,.. ..7' • I... ' ' - _4* •',. ' . ',? •, 4. ., , - . -. 7-.,'. -. 1._,- - •- . - , - .4 - I. •''_ . . . ... .. -7 - . .7 4. - , . t, ,.,,r . - . 4,• - I. ', •'4 4 - - - -.7 . -'7 ' -p,, •. . •;7..., :.;.' ol :- . - _ :P ermit Type: BLDG-Residential Application Date: 09/28/2016 Owner: TRUST MIDDLETON GLEN P&ROCIO LIVING TRUST 07-17-09 Work Class: ' Addition . Issue Date: 01/11/2017 Subdivision: Statu - Closed - Finaled Expiration Date: 01/08/2018 Address: 2706 Inverness Dr .;. - . Carlsbad, CA 92010-6520 IVR Number: 717.427 - Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date . . Checklist Item - COMMENTS Passed - - - BLDG-Plumbing Final Yes - . . BLDG-Mechanical Final . - -. . Yes - . BLDG-Structural Final Yes -:- - - BLDG-Electrical Final Yes -L -v:--: -• -. .4 . 4 .. 4 4_I .4. - ; - L -. - . 1 4., •_ '4 p 4 p.• • - •.. - ',September 12, 2017 Page 30f3 - P'n ~n-jl Permit Type: BLDG-Residential Application Date: 09/28/2016 Owner: TRUST MIDDLETON GLEN P&R0C10 LIVING TRUST 07-17-09 Work Class: Addition Issue Date: 01/11/2017 Subdivision: Status: Closed - Finaled Expiration Date: 01/08/2018 Address: 2706 Inverness Dr Carlsbad, CA 92010-6520 IVR Number: 717427 Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date - BLDG-34 Rough 025675-2017 Failed Paul Burnette Reinspection Complete V • . Electrical . ' V Checklist Item COMMENTS Passed V BLDG-Building Deficiency No V 06/12I2017 - 06/12/2017 BLDG-84 Rough 025928.2017 Passed Paul Burnette Complete Combo(1424,3444) • Checklist Item COMMENTS Passed V V BLDG-Building Deficiency. Yes . 4. BLDG-14 Yes - Frame-Steel-Bolting-Welding V • V (Decks) V V BLDG-24 Rough-Topout - Yes V BLDG-34 Rough Electrical . Yes I - tVV VAV V . 1 BLDG-44 Yes V V t ' Rough-Ducts-Dampers - .06/14/2017 06/14/2017 ;' BLDG-16 Insulation 026220.2017 Passed Paul Burnette Complete V V Checklist Item COMMENTS Passed V - V• - V - BLDG-Building Deficiency Yes V V V 06/20/2017 06/20/2017 BLDG-17 Interior 026728-2017 Passed Paul Burnette V Complete Lath/Drywall V V • V Checklist Item COMMENTS Passed V : - • V s V V BLDG-Building Deficiency V Yes V V. 07/11/2017 V 07/11/2017 BLDG-27 Shower 028405-2017 Passed Paul Burnette Complete Pan/Tubs V Checklist Item COMMENTS Passed V V V V BLDG-Building Deficiency Yes 09/11/2017 09/11/2017 BLDG-Final 034209-2017 Failed Andy Krogh Reinspection Complete V - V • Inspection - V' V V Checklist Item COMMENTS Passed I V V • V V - BLDG-Building Deficiency Add smoke detector to hallway No V - T • - r V V ' BLDG-Plumbing Final V Yes V V - V V - •. ' V - BLDG-Mechanical Final Yes V ••V -. - V V BLDG-Structural Final Yes - V •V - - V BLDG-Electrical Final Kitchen outlets including island to be gfci No V V - •V V ' V protected V V V 09/12/2017 - 09/12/2017 - BLDG-Final ' 034385.2017 Passed Andy Krogh Complete • - Inspection V - I V V September 12, 2017 - - V Page 2of3 V_V . V •V - V V V r Permit Type: BLDG-Residential Application Date: 09/28/2016 Owner: TRUST MIDDLETON GLEN P&ROCIO LIVING TRUST 07-17-09 -. - Work Class:, Addition Issue Date: 01111/2017 Subdivision: 7 .'Status: Closed - Finaled ' Expiration Date: 01/08/2018 Address: 2706 Inverness Dr Carlsbad, CA 92010-6520 IVR Number: 717427 Scheduled Actual - Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete - Date. Start Date -. - - 06/20/2017 BLDG-18 Exterior 026823-2017 Passed Paul Burnette Complete Lath/Drywall ChecklistItem COMMENTS Passed - - BLDG-Building Deficiency No - - 03/03/2017 03/03/2017 BLDG-22 016325-2017 Passed Paul Buinette Complete Sewer/Water Service Checklist Item COMMENTS Passed • ' .. BLDG-Building Deficiency Yes 03/08/2017. • 03/08/2017 BLDG-11 015829-2017 Passed Paul Burnette Complete .., Foundation/Ftg/Pier - . s (Rebar) - : - Checklist Item COMMENTS Passed • - BLDG-Building Deficiency Yes • 05/02/2017 ,05/02/2017 BLDG-IS 021826-2017 Passed Paul Burnette Complete - - - Roof/ReRoof (Patio) - - Checklist Item COMMENTS Passed - - . •/• BLDG-Building Deficiency Yes 06/30/2017 05/30/2017 BLDG-I4 024709-2017 Failed Paul Burnette Reinspection Complete Frame/Steel/Bolting/ - Welding (Decks) - ,--- . Checklist Item - COMMENTS - Passed - BLDG-Building Deficiency No 06/02/2017 06/02/2017 BLDG-I4 025150-2017 Partial Pass Andy Krogh Reinspection Incomplete -'. -. .. Frame/Steel/Bolting/ .4. Welding (Decks) Checklist Item COMMENTS . Passed -. • . - . - . BLDG-Building Deficiency Hold downs as noted on card Ok to sear Yes walls (2) 06/08/2017 06/08/2017 • BLDG-I3 Shear 025677.2017 Passed Paul Burnette Complete -, • - Panels/HD (ok to - - '• • wrap) I - Checklist Item COMMENTS Passed • - • BLDG-Building Deficiency Yes - - ' BLDG-I4 • 025676-2017 Failed . Andy Krogh Reinspection Complete • . " • Frame/Steel/Bolting! - Welding (Decks) - p'_ - . • Checklist Item COMMENTS Passed -. . •.• BLDG-Building Deficiency Not ready No . & - . . September 12, 2017 - - •. . Pagel of 3 43 3 'St .'.:. " ':'• ' RECEIVED : JUN 0 2 2017 CITY OF CARLSS3AD' fNSPECT1O( REPORT BUILDING DIVII,ION PROJECT NAME Middleton Residence INSPECTION MATERIAL IDENTIFICATION ADDRESS .2706 Inverness Dr. 0 CONCRETE CONC. MIX NO. & lb/in2 * Carlsbad, Ca: - . . . 0 REINF. STEEL GROUT MIX NO. & lb/in2 ARCHITECT Spaces Renewd 0 MASONRY MORTAR TYPE & lb/in2 ENGINEER `PC Enginserrrig j PT CONCRETE 'R€H'4F STEEL(3R./SIZE CONTRACTOR pewer BkMkA ' '0 flE1-1) WELDING STRUCTURAL STEEL OTHER . ' - r - 0 SHOP WELDING HIGH-STRENGTH BOLT INSPECTION DATE 1006-0172017-' 0 BATCH PLANT MASONRY BLOCK PLAN FILE/OTHER •' -. 0 EXP. ANCHOR OTHER . '.. BLDfLP,ERM!T/O.THER.. C63700 - - . . OTHER.. Shear wall MATERIAL SAMPLING El 'CONCRETE El MORTAR" . El GROUT El FIREPROOFING El MASONRY BLOCK - -- El 'REINFORCING STEEL 'El STRUCTURAL STEEL El BOLTS El OTHER - - INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS - '- PLEASE NOTE ANY RE-INSPECTION, TESTING, OR OTHER PROJECT ISSUES. . . Lvisüaliy, insected (1j Mark-.C.:she.a(wallasnbted bIow. - - Locati6n: (1) 46' Mark C wall àlong.the (E) rearwall Sheathing: 15/32", structural 1, sparirating 32/16, plywood.. - Nails: 2-3/4 x.132" (8d common) collated gun nails. 3" o.c. Note: The following components were checked; framing members for size and grade, hold dowry sizes and fastening, anchor bolts, nailing for size spacing edge distances and flush with the surface A35 s 9' o c OR EXCEEt PLAN CALLOUTS'AND CBC No discrepancies were observed or noted All work is subject to City of Carlsbad approval '4'---, -: -. 3- 344, - :1 eihcaon anN PRINTED NAME Craig Bechtel CERTIFICATION NO ICC 5265295 SD-1024 SIGNATURE 3 -. * - S • _ ' . S. S) ' ., RECEIVE: I, JUN 02 2017, INSPECTION REPORT CITY OF CARLS3AD' BUILDING DIV61ON : PROJECT NAME Middeton Residence INSPECTION MATERIAL IDENTIFICATION ADDRESS 2706 Inverness Dr. 0 CONCRETE CONC.MIX NO & Win Carlsbad Ca 0 REINF STEEL GROUT MIX NO & lb/in 2 I- d -ARCHITECT S paces A enewe Q SMASONRY MORTAR TYPE.& lb/in2 - ENGINEER PCSD Engineering 1] 'P T OGNCREPE 'REINF SPEEL G1 /SIZE CONTRACTOR 0 FIELD WELDING STRUCTURAL STEEL OTHER 0 SHOP WELDING HIGH STRENGTH BOLT INSPECTION DATE 06-01 2017 0 BATCH PLANT MASONRY BLOCK PLANFILE/OTHER . - 0 EXP. ANCHOR OTHER -- BLDG PERMIT/OTHER CB16 3700 OThER Epoxy all thread rods - MATERIAL SAMPLING i:i CONCRETE j MORTAR •, LI GROUT 0 FIREPROOFING LI MASONRY BLOCK EJ REINFORCING STEEL STRUCTURAL STEEL R BOLTS fl OTHER INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS . - PLEASE NOTE ANY RE-INSPECTION, TESTING,-Q TESTING,-QR OTHER PROJECT ISSUES. 'I>observedthe.poxy proces 'of -5T8 -all-thread rods into Iha (E) concrete as noted below Epoxy product Simpson SET XP #077C1320 exp 01/19 - Locations: (2) HDU5 hold downs at the Mark C shear wall at the (E) rear wall. Approx. (18) sill plate anchor rods throughout at plate . breaks' and to achieve the(N) shear,wall schedule spacing call outs. . Hole diameters 3/4 Effective embedment: 12' at the hold downs per the schedule on det. 6/SD-1. 5" at the sill plate anchors per det. 3/SD-1. l4ote AlL bores were diWeci wth a rotary, hartrrier d.rI4SarK& carbide bpped\b then bfu.sbed.,witK a ryIon brush ard, bIowr out with compressed ann until dust free pnorto injecting the epoxy The entireprocedure meets or exceeds plan details and ESA 2508 v': ----. - ,, ----. require No dlscreianc3es weje observed or rioted LJ All work is subject to City, of Carlsbad approval or * I I S. -' - ..• - - .' . ; I I 70, .., Certification of Compliance: All work, unless otherwise noted, compiles with applicable codes and the approved plans and specificalions:IH PRINTED NAME Craig Bechtel -' CERTIFICATION NO ICC 5265295 50-1024 SIGNATURE .., . - . •L._.L - -. * •'• - •-1. . I - • - •1 r, ,• .-.. -'' I . - ••• 'S * 5 4 - 4".. -. EAST COUNTY SOIL CONSULTATION .•: • .' - 5 AND ENGINEERING, INC. 10925 HARTLEY ROAD, SUITE "I" SANTEE, CALIFORNIA 92071 (619) 258-7901 ' Fax 258-7902 .5. " 1'•'•.. S Glen &-Rocio Middleton December 22, 21016 $ .. 2407 Inverness Drive Project No. 16-1107A5 •. , .', Carlsbad; California 92010 .4* i S. •'•45 •.. S '& Subject: • Foundation Plan and Details Review Proposed Residential Addition (Middleton Residence) • , 2407 Inverness Drive Carlsbad, California 92010 "' - Reference: "Limited Geotechnical Investigation, Proposed Residential Addition (Middleton Residence), 2407 Inverness Drive, Carlsbad, California 92010", Project No., 16: • 1107A5, Prepared by East County Soil Consultation and Engineering, Inc., Dated - November 17, 2016. - •.. ••' 5 5 5-, 5 ,S • • j I Dear Mr. & Mrs Middleton In accordance with your request, we have reviewed the foundation plan and details prepared by • PCSD of San Diego, California for the proposed residential addition at the subject site. •' -; The foundation • plan and details were found to be in substantial conformance with; the • recommendations provided in the referenced geotechnical report. Our firm should observe the -foundation excavations for proper size and embedment into competent bearing soils. ' ': If we can be of further assistance, please do not hesitate to contact our office. ' ,I.-1',•' • • ,, -• . '. S .-: •• . • ,, Respectfully Submitted, GE 2704 Cr EXR ••--- '- Mamadou.Saliou Diallo, P.E. ' RCE 54071, GE-2704 , : 5MSD/md -. - -: .',. - -- •-:. ; - 'r . ,. .. -., - 4_ - ,,.I ,, -...'• :- .. : Carlsbad 16-3700 December 19, 2016 r 4 _. ,, In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed : requires special inspection, structural observation and construction material testing. 'roject/Permit Project Address:-Z Lj 7 TN )/W(S DI' CM (5Af CA A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNERIAUTHORlZED AGENT. Please check if you are Owner-Builder .. - Q. (If you checked as owner-builder you must also complete Section B of this agreement.) Name: (Please A i fL— ,, - . Mailing Address_i 0 ,K_J H '1l[V/,vtA/UOS ,CA _C7 Ze '7' EmailD CO—Phone: . I am: OProperty pwner roperty Owners Agent of Record LiArchitect of Record LiEngineer of Record - I - 2 ' . • State of California Registration Number Expiration Date:_ '-i;'- _O AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read - -'4 understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations construction materials testing and off site fabrication of building components as prescribed in the statement of ---" special inspections rioted on the approved plans and, as required by the California Building Code. - - Signature .__---------. Date B CO OR 'S STATEMENT OF RESPONSIBILITY (07 CBC Ch 17 Section 1706) This section must be completed by the contracto, udder I owner builder Contractors Company Name L 'X LAP4O~(P d, 391C. Please check if you are Owner Builder Cl & Name (Please print) J?o /" INI' A Mailing Address 0 !3o') L$ ILI j/ pflS 4o_7_1 Email _D-'c _L LkOk OEiLone__'7Lo ZL&90 Stábo1California contractor's License Number: _Cl 6 2 jj 1 Expiration Date: _ ij_/~oi_1 ' • . - -' ,.• -. • .,, I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; • .I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; - - . - • "[will have in-place procedures for exercising control within our (the contractor's) organization, for the method and. - - - frequency of reporting and the distribution of the reports; and - • I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. . I will provide a final report / letter in compliance with CBC Section 1704.1.2 prior to requesting final • -' inspection. Date .- 2&_Zg,±t_,.__. -' B-45, Page 1 of 1 Rev. 08/11 .- I ' " ',• '-•_ _, - , .-. . - _,• -- . .• -•-. V EsGil Corporation In Partnerslizp with government for Building Safety .DAfE: January 5, 2017 U APPLICANT '; Q-1RIS. '- •.JURlSDlCTlON: Carlsbad U PLAN REVIEWER U FILE PLAN CHECK NO.: 16-3700 SET: III - r - , PROJECT ADDRESS 2706 Inverness Dr '-.- -- ,: - . ROJECT NAME: Addition & Remodel for Middleton Residence The plans transmitted herewith have been corrected where necessary and substantially comply -. with the jurisdiction's building codes - '-. "011 The plans transmitted herewith will substantially comply with the jurisdiction's ' codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enblosed check list and should be corrected and resubmitted for a complete recheck. 171'~-The check list transmitted herewith is for your information The plans are being hld at EsGil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to f - * I .. EsGil Corporation staff did not advise the applicant that the plan check has been completed EGil Corporation staff did advise the applicant that the plan check has been completed 'Person contacted Telephone # ' Date contacted -i7) Email Mail Telephone Fax In Person - EIIREMARKS r By AbeDoliente Enclosures ¼ EsGil Corporation E GA EJ E MB PC 12/30/16 - - -- -. t •-,. - :- .- - - •- - - - .,• 9320 1468 Fax (858) 560 1576 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560 • .• - a • -- .,• -•• - - ,F 4• ;• 4. EsGil Corporation In Partnership with government for (Bui(ding Safety DATE: December 19, 2016 : - <PPLICANT A IS. - - "'JURISDICTION: Carlsbad / D PLAN REVIEWER LJ FILE PLAN CHECK NO.: 16-3700 SET: II -PROJECT ADDRESS: 2706 Inverness Dr PROJECT NAME Addition & Remodel for Middleton Residence 4 ET The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes F71, The plans transmitted herewith will substantially comply with the jurisdiction's y codes when minor deficiencies identified below are resolved and checked by building department staff. EJ The plans transmitted herewith have significant deficiencies identified on the enclosed check list ? and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil : Corporation until corrected plans are submitted for recheck. - The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person : HThé applicant's copy of the check list has been sent to: Dominic Ramirez - * EsGil Corporation staff dud not advise the applicant that the plan check has been completed EsGil Corporation staff did advise the applicant that the plan check has been completed. . -• ••• . ' Person contacted: Dominic rarnirez Telephone #: 760-214-8880 I' Date contacted _- ('9) (b) Email dominic@luxhomebuilder.com * 9_,Maii'f Telephone-.j Fax in Person REMARKS * , By: Abe.Doliente - Enclosures: . • ' - EsGil Corporation - - -' LI GA [I EJ LI MB LI Pc 12/12/16 - . . •1, • ii ,• .. . . 9320 Chesapeake Drive Suite 208 • San Diego California 92123 • (858) 560-1468 • Fax (858) 560-1576 -: . S,S_S-• .5 - 1.• '•. S Carlsbad 16-3700 : : December 19, 2016 - S , NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. .' S Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects) For expeditious processing, corrected sets can be submitted : • - in one of two ways: : 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad S Planning, Engineering and Fire Departments. 2. Bring TWOT corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. ...r ,' Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire S Departments. NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete PLANS 1. All sheets of plans must be signed by the person responsible for their -. preparation. The structural portions and the structural calculations must be signed and sealed by the California state licensed engineer or architect responsible for their preparation (California Business and Professions Code) S • - • Signatures will be verified before the plans are approved. 3. Please include the north arrow on the site plan. There is no response. S • FIRE PROTECTION 6. Show on the plans the locations of the required smoke alarms and carbon monoxide alarms (whether existing or to be added). MEP plan shows CO in most of the areas. One more CO is required outside the master bedroom hall way. Now, show smoke alarms at all the areas where you show the CO. Those are all required areas. FOUNDATION REQUIREMENTS 15. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents. Al Iv Carlsbad 16-3700 December 19, 2016 MECHANICAL 20. Show on the plans the location, type and size (BTU's) of all heating and cooling appliances or systems. There is no response. received. MISCELLANEOUS S .'... S To speed up the review process,note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. . : • Please indicate here if any changes have been made to the plans that are not a - result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans 54 ._ • •! Have changes been made to the plans not resulting from this correction list? Please indicate -• •:' Yes U No U • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208 San Diego California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Abe Doliente at • EsGil Corporation Thank you S j • - S. - ••' -. 5, 5 -. SP-•t. •' .- S I -.•" _5 5' -5.- 5- . . -,- - .5. . .. - *. •,' ''_: • -, 5 5 - . . • S 5. r - -, S • • S•••••__ ••' -.- :- • - V EsGil Corporation In cPartnersfizp with government forBw(ding Safety DATE October 5,-2016 J APPLICANT -: "JURIS. JURISDICTION: Carlsbad 0 PLAN REVIEWER 0 FILE PLAN CHECK NO 16-3700 SET I $ r .. :OJECT ADDRESS: 2706 Inverness Dr . PROJECT ,NAME: Addition & Remodel for Middleton Residence Theplans transmitted, herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes ' F] The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building ; department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck - -. 't. -. - • S • ..- The check list transmitted herewith is for your information The plans are being held at EsGil - - Corporation until corrected plans are submitted for recheck EII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person vJ,The applicant's copy of the check list has been sent to :Dominic Ramirez- F71 EsGil C6rporation staff dud not advise the applicant that the plan check has been completed EsGil Corporation staff dud advise the applicant that the plan check has been completed Person contacted Dominic ramirez Telephone # 760-214-8880 Date contacted lois/i (by K) Email dominic@luxhomebuilder com Mail JTeiephone Fax in Person LI1 REMARKS -.,;. •i: •-. . - . By:Abe Doliente Enclosures 'f EsGil Corporation E GA EEJ 0 MB El PC 10/3/16 9320 Chesapeake Drive Suite 208 • San Diego California 92123 • (858) 560-1468 • Fax (858) 560-1576 :. 4 - * -s,.. .• Carlsbad 16-3700 October 5, 2016 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES -S. PLAN CHECK NO.: 16-3700 JURISDICTION: Carlsbad PROJECT, ADDRESS: 2706 Inverness Dr FLOOR AREA: Addition - 874 SF STORIES: 1 Remodel 1792 SF - HEIGHT REMARKS:' DATEPLANS RECEIVED BY DATE PLANS RECEIVED BY .•. J,URISDICTION:- .• ESGIL CORPORATION: 10/3/16 DATE INITIAL PLAN REVIEW PLAN REVIEWER: Abe Doliente COMPLETED: October 5, 2016 FOREWORD (PLEASE READ) This plan review is Iimited'to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, .Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on .,,,regulations enforced by the Building Department. You may have other corrections based on- Jaws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of ' a building permit Present California law mandates that construction comply with the 2013 edition of the California Code of Reulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC, 2012 UPC, 2012 UMC and 2011 NEC - The above regulations apply, regardless of the code editions adopted by ordinance The f6110wing items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of .'*•' -- the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. • - - To speed up 'the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc.; .. Be sure to enclose the marked up list when you submit the revised plans t - - ra - Lr 3,. - • • , - - - . • , , - • . Carlsbad 16-3700 October 5, 2016 Please make all corrections, as requested in the correction list. Submit FOUR new, complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted - in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of • Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, '. 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. '• Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. - • -•. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by • • EsGil Corporation is complete. 'PLANS I .. All sheets of plans must be signed by the person responsible for their preparation. The structural portions and the structural calculations must be signed and sealed by the California state licensed engineer or architect . responsible for their preparation. (California Business and Professions Code). 2. . Specify on the Title Sheet of the plans the gross floor area of each element of - this project. Please be consistent. Project Data shows 2 different areas for the addition; 647 SF and 874 SF. Which one is the correct one? Energy calculations used 874 SF. Section R106.2. 3:'Please include the north arrow on the site plan. . 4.- Revise the occupancy group from Ri to R3/U. . '- ••, . . . ,'. 5. • On the cover sheet of the plans, specify any items that will have a deferred • •. submittal (trusses, etc.). Additionally, provide the following note on the plans: - "Submittal documents for deferred submittal items shall be submitted to the - • • registered design professional in responsible charge, who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in -• ... general conformance with the design of the building. The deferred submittal '.items shall NOT be installed until their design and submittal documents have 'been approved by the building official." * • • : . FIRE PROTECTION . 6. • Show on the plans the locations of the required smoke alarms and carbon - monoxide alarms (whether existing or to be added) 5 • • • - - i• .....• ...' .. Carlsbad 16-3700 :- October 5, 2016 - ROOFING 7 Specify on the plans the following information for the skylights, per Section R106.1.1: a) Manufacturer's name and product name/number. . • ' b) : ICC approval number, or equal. 8. . Show the required ventilation for attics. The minimum vent area is 1/150 of attic - area (or 1/300 of attic area if at least 40% (but not more than 50%) of the required vent is located no more than 3' below the ridge). Show on the plans the area required and area provided Section R806.2. 9. . Where éave vents are installed, insulation shall not block the free flow of air. A minimum of 1" of air space shall be provided between the insulation and the roof sheathing Section R806.3. 10: 'Note on the plans: "Attic ventilation, openings shall be covered with corrosion-resistant metal mesh with 1/16" minimum to 1/4" maximum openings Section R806.1. , 11 Show location of attic access with a minimum size of 22"x30", unless the maximum vertical headroom height in the attic is less than 30". Access must be . provided to each separated attic area (if over 30 sq. ft.), shall be located in a -. hallway or other readily accessible location and 30" headroom clearance is ' required above the opening Section R807.1. GARAGE AND CARPORTS -' ' :. Show a self-cldsing; self-latching door, either 1-3/8" solid core or a listed 20 .. minute assembly, for openings between garage and dwelling Section R302.5.1.. - specify this requirement for door D09 FOUNDATION REQUIREMENTS - 13. Provide a4 copy of the project soil report. The report shall include foundation. . design recommendations based on the engineer's findings and shall comply with - '-- '.Section R401.4. This is a city requirement. * - 14. -; If the soils engineer recommends that he/she review the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building -bfficiál in writing that: .' - - a). The building pad was prepared in accordance with the soils report, - - b) The utility trenches have been properly backfilled and compacted, and C) The foundation excavations, the soils expansive characteristics and - bearing capacity conform to the soils report." , I Carlsbad 16-3700 October 5, 2016 -Provide a letter from the soils engineer confirming that the foundation plan, -, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report) -.. :. 16. Note on plans that surface water will drain away from building and show drainage pattern. Finish grade may be sloped away from foundations at a 2% slope (less 4 - restrictive than the 5% slope given in the CBC/CRC). FRAMING (_ Provide truss details and truss calculations for this project. Specify truss identification numbers on the plans. Please provide evidence that the engineer-of-record (or architect) has reviewed the truss calculation package prepared by others (i.e., a "review" stamp on the truss calculations or a letter) CBC Section 107.3.4.1. The plans shall indicate that special inspection will be provided for the following .' work (CBC Chapter 17 and Section 107.2). Use the attached city special inspection form a) ' Expansion anchors. Periodic special inspection should be provided for ' - - anchors installed in hardened concrete. Section 1705.3. - . MECHANICAL 20 Show on the plans the location, type and size (BTU's) of all heating and cooling appliances or systems. t: - . .- 3 . ELECTRICAL 21 For a single-family dwelling unit (and for each unit of a duplex), show that at least one receptacle outlet accessible at grade level will be installed outdoors at the '-- ' front and back of the dwelling. CEC Article 210.52(E). This receptacle must be GFCI protected - • • ENERGY CONSERVATION Show the requiredinssulation R-15 for the new walls and R-38 for the new - ceiling/attic. MISCELLANEOUS - 3 23 Provide supporting structural design calculations to show how arrived at the proposed roof beams, shear walls and HD's on sheets Si and S2 of the plan. c.. 4 -. . • 3 - Carlsbad 16-3700 October 5, 2016 .'.. :, • :To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, : etc.''-- Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe : them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate Yes U , No U - c•._. • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Abe Doliente at EsGil Corporation Thank ' you ir - '• •1 1' - • -- 4 . - I . - •].iSi . + -. _4+ •- - -- -, - _I._. • + - - Ii - - I. : . •+. - .. - -- - 4 C- + -- -5 -- - . '-1.-• j - .- . ..-. - Carlsbad 16-3700 'October 5,2016 - [DO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE ... . . - . JURISDICTION: Carlsbad PLAN CHECK NO.: 16-3700 4 - - F EPAREDBY Abe Doliente DATE October 5, 2016 - BUILDiNG ADDRESS: 2706 Inverness Dr BUILDING OCCUPANCY R3/U - 'ft Jurisdiction Code Cb By Ordinance - - $1,080.461 Bldg. Permit Fee by Ordinance ' Plan Check Fee by Ordinance * I $702 301 Type of Review. Complete Review Structural Only - - LI Other LI Repebtive Fee : -. -, - - - -. -. Repeats - Hourly _____________ Hr @ * 11 : EsGil Fee Comments Jn addition to the above fee, an additional fee of $43 is due (1/2hour fôrtheCalGreen:review. - Sheet 1 of 1 -, -• - .. - . - macvalue.doc + - .• .-. -- , . = _* - -..- '--, 1; - . '••' .. - - . • ,; - BUILDING PORTION AREA (Sq. Ft.) i Valuation Multiplier Reg. Mod. VALUE ($) Addition 874 166.81 145,792 Remodel- - 17921, 45.78 82,038 - -. Air Conditioning Fire Sprinklers - TOTAL VALUE - 227,830 :. T PLAN CHECK Community & Economic CITY 0 F D ,i AI Development Department ' V WV 1635 Faraday Avenue TRANSMITTAL - Carlsbad CA 92008 CARLSBAL1Y www.carisbadcgov DATE: 10/11/2016 PROJET NAME: MIDDLETON FAMILY ADDITION! REMODEL PROJECT ID: PLAN CHECK NO: CB1637J0 SET#: 1 ADDRESS: 2706 INVERNESS APN: 2081124600 VALUATION: $227,830 SCOPE OF WORK: 1792 SF REMODEL AND 874 SF ADDITION This plan ch4k review is complete and has been APPROVED by: LIND DEVELOPMENT ENGINEERING DIVISION Final Inspection by Construction Management & Inspection Division is required: Yes LII Fslo EZ 'o detemine status 'by one or more of these divisions listed below, please contact 760-602-2719 - This plan chècreview is NOT COMPLETE. Items missing or incorrect arejistedon.' the attached cIeckIist. Please resubmit amended plans as required. Plan Check Corments have been sent to: DOMINIC@LUXHOMEBUILDER.COM cNi'JW1) ENGINEERING W. 760-602-2750 - E Chris Sexton F-1 Chris Glassen Greg Ryan ,760-602-4624 760-602-2784 760-602-4663 CIris.Sexton@carIsbadca gov Christopher.Glassen@carlsbadca.gov Gregory. Ryan@carlsbadca.gov Gina Ruiz, Linda Ontiveros M 760-602-2773 F-1 Cindy 'Wong 760-602-4675 760-602-4662 Gina.Ruiz@carlsbadca.go1 Linda.Ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov ValRay Nelson Dominic Fieri F] 760-602-2741 760-602-4664 I ValRay.Marshall@carlsbadca.gov Dominic.Fieri@carlsbadca.gov Remarks ay widths ig or proposed sewer lateral g or proposed water service on signed approved plans: No. LIIIII LIIII Right-of-way width & adjacent streets Show on site plan -f 4. LIII] LIII Drainage patterns EII =Building pad surface drainage must maintain a minimum slope of one ercent towards an adjoinig street or an approved drainage course. . LII =ADD THE FOLLOWING NOTE: "Finish grade will provide a minimumt positive drainage of 2% to swale 5 away from building LIII IJ Existing & proposed slopes and topography - LIII t:IIII1Size, location, alignment of existing or proposed sewer and water sery ce(s) that seriesthe project. Each unit requires a separate sejvice; however, second dwelling units and apartment complexes are a.91. exception. LIII LIIi Sewer and water laterals should not be located within proposed drive, ays per standards Include on title sheet: Site address I LIJ 7J Assessors parcel number '1 iIIIIJ LZII Legal description/lot number EI 1I1 For commercial/industrial buildings and tenant improvement Drojects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, w ehouse, office, etc.) previously approved. JIII EJ Show all existing use of SF and new proposed use of SF. Example: Tenant improvement for 3500 SF of warehouse to 3500 SF of office. " I Lot/Map No LOT 52 MAP 9935 Subdivision/Tract CT 7612 Reference No(s): - •. . E-36 Page 2of6 . -. . REV : - . MIDDLETON FAMILY ADDITION/ REMODEL rL Outstanding issues are marked with EI . Items requirements are marked with I7 or have intent 1. SITE PLAN . Provide a fully dimensioned site plan drawn to scale. Show: - i.i LZIII North arrow ' J IIIJ Driv EIIIII LZI Existing & proposed structures Exi LIII [III] Existing street improvements [III LIIII] Exi [1111] LI Property lines (show all dimensions) [1111] Sub 11 1i Easements - DW t.. I CHECK NO # CB163700 t conform to permit ally beet left blank. MIDDLETON FAMILY ADDITION! RE PLAN CHECK NO # CB163700 2 DISCR TIONARY APPROVAL COMPLIANCE . N/A E1 c:i Pt1oject does not comply with the following engineering conditions of approval for project no 4. 3 DEDICATION REQUIREMENTS LII LII Dedication for all street rights-of-way adjacent to the building site and any storm drain or N/A utility easements on the building site is required for all new buildings and for remodels with a vlue at or exceeding $ 24.000.00 , pursuant to Calsbad Municipal Code Section 18.40.030. .1 Dedication required as follows 4 IMPR( VEMENT REQUIREMENTS , Al, needed public improvements upon and adjacent to the building site must be constructed CURB at time of building construction whenever the value of the construction exceeds SIDEWALK . $120,000.00, pursuant to Carlsbad Municipal Code. Section 18.40.040. . AND GUTTER . P blic improvements required as follows EXIST 1 E1 Construction of the public improvements must be deferred pursuant to Carlsbad IV unicipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee, so we may prepare the necessary Neighborhood lrprovement Agreement This agreement must be signed notarized and aproved by the city prior to issuance of a building permit a.'. jJ FLture public improvements required as follows: ' . , - !•-, E-36 , Page 3 of 6 REV 6101/12 - • , 44 . ',•' . \ MIDDLETON FAMILY ADDITION! REMODEL E-36 GRADING PERMIT REQUIREMENTS .• The conditions that require a grading permit are found in section 15.16 of the Municipal Code. - 1J=Inadequate information available on site plan to make a determination on grading requirements Include accurate grading quantities in cubic ya ds (cut, fill, import, export and remedial). This information must be included on the plai s. If no grading is proposed write: "NO GRADING" Grading Permit required. NOTE: The grading permit musi be issued and rough grading approval obtained prior to issuance of a building permit. -. E1 Lii Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) All required documentation must bi provided to your Engineering Construction Inspector , The inspector will then provide the engineering counter with a release for the building permit. - :i LZJ No grading permit required EJ LIII Minor Grading Permit required. See additioraI comments forproject- specific requirements. ' . ,).; •1 .- MISCELLANEOUS PERMITS - .• . LII ,_RIGHT-OF-WAY PERMIT is required to do work in city ri ht-of-way and/or private work adjacent to the public right-of-way. Types of work include but are not limited to: street improvements, tree trimming, driveway construction, tying mt public storm drain, sewer and water utilities. 11 LI.J Right-of-way permit required for FOR ANY WORK, MATERIALS OR STAGING IN ROW - 4 .-- I 1' i - Page 4of6- - _i . REV 6/Oi/12 MIDDLETON FAMILY ADDITION! I EMOL PLAN CHECK NO # CB163700 . '7 STORM WATER / C E I • • - '.• _••, --,• •,, I -t ..... '-4 - ,• . ., 4 E-36 JLIUII ..UIIIIJIIdIII. - Project Threat Assessment Form complete. Enclosed Prbject Threat Assessment Form incomplete. Requires Tier 1 Storm Water Pollution Prevention Plan. Please complete attached form and return (SW ) . • Requires Tir 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2 SWPPP, payment of processing fee and review by city. 'velopment (SUSMP) Compliance Storm Water Standarèis Questionnaire complete. - Storm Water Standards Questionnaire incomplete. Please make the corrections, re-sign' the questionnaire and resubmit with next submittal. Project is subject to Standard Storm Water Reqiiirements. See city Standard Urban Storm Water Management Plan (SUSMP) for reference. . http://www.carlsbadca.gov/business/buildincilDocuments/EnQStandsw-stds-v014-ch2.pdf Project needs to incorporate low impact development strategies throughout in one or more of the following ways: - - JJ Rainwater harvesting (rain barrels or cistern) J Vegetated Roof -' EJ Bio-retentions cell/rain garden EJ Pervious pavement/payers - -. Flow-through planter/vegetated or rock drip line . Vegetated swales or rock infiltration swales - U Downspouts disconnect and discharge over landscape ElOther: . I . Page 5of6 - - REV 6/01/12 T: MIDDLETON FAMILY ADDITION/ REMODEL . LAN CHECK NO # CB163700 ' 8 WATER METER REVIEW Domestic (potable) Use E1 LZJ What size meter is required? Where a residential unit is required to have an automatic fire extinguishing system, the minimum meter size sh II be a 1" meter. NOTE: the connection fee, SDCWA system capacity charge and the water treatment capacity charge will be based on the size of the meter necessary to meet the water use requirements. 1fl For residential units the minimum size meter shall b 5/8", except where the residential unit is larger than 3,500 square feet d on a lot larger than .• one quarter (1/4) acre where the meter size shall be 4 S 9. FEES 4 J Required fees have been entered in building permit. L:J c:i Drainage fee applicable Added square feet Added square footage in last two years9l FJ yes jJ no 4 Permit No Permit No. Project built after 1980 j ayes Jno Impervious surface >50%. -Jyes LImo Impact unconstructed facility jyes Elino EIIJ Fire sprinklers required Jyés -.L1 no (is additi n over 150' from center line) Upgrade 0 yes no- LIIJ EZJ No fees required •- t . 10 ADDITIONAL COMMENTS r 5 4 - I 1 . , - Attachments: Engineering Application ED Storm Water LJ Right-of-Way AppIicatIon/nfo. - EJ Reference Documents E-36 . Page 6of6 ' -; •. - REV 6/01/12 :. 'r I --. Fee Calculation Worksheet ENGINEERING DIVISION • Prepared by: Address: Fees Update by: Date: GEO DATA: LFMZ: I B&T: Bldg. Permit #: / Date: Fees Update by: Date: EDU CALCULATIONS: List types and square footages for all uses. T Types of Use: Sq.Ft./Units EDU's: : ; Types of Use: Sq.Ft./Units EDU's: Types of Use: SqFt.iUnits EDU's: Types of Use: : Sq.Ft./Units EDU's: ADT CALCULATIONS: List types and square footages for all uses. Types of Use Sq.Ft./Units ADT's Types of Use: Sq.Ft./Units ADT's: 1' Types of Use: S - Sq.Ft./Units ADT's: ;:. Types of Use: - Sq.Ft./Units ADT's: • FEES REQUIRED: Within CFD DYES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) UNO ' 1. PARK-IN-LIEU FEE:[JJNW QUADRANT DNE QUADRANT USE QUADRANT DWQUADRANT ADT'/UNITS: X FEE/ADT: I .23RAFFIC IMPACT, FE: ADT'/UN ITS: F X FEE/ADT: I 4 BRIDGE & THOROUGHFARE FEE: DIST. #1 DIST.#2 JDIST.#3 • (USE SAN DAG)ADT'/UNITS X FEE/ADT: I FACILITIES MANAGEMENT FEE ZONE: ADT'/UNITS X FEE/SQ FT /UNIT =$ : SEWER FEE EDU'3 X FEE/EDU I BENEFIT AREA: EDU' X FEE/EDU: I 4 '-H- DRAINAGE FEES: PLDA: EJHIGH EIJMEDIUM EILOW ACRS: X FEE/AC: I • POTABLE WATER FEES: -. UNITS • CODE CONN. FEE METER FEE SDCWA FEE TOTAL - ss4j may not repr1sent a comprehensive list of fees due for this project. Please contact the ui1ding division at (760) 602-2719 for a complete listing of fees*** - S •c•_ . - S .5 - _S• \ • S - -- I - PLANNING DIVISION BUILDING PLAN CHECK Development Services X-0 Planning Division c-IT Y 0 F REVIEW CHECKLIST 1635 Faraday Avenue CARLSBAD P-28 (760)602-4610 - www.carIsbadca.ov DATE 8/29/16 PROJECT NAME PROJECT ID PLAN CHECK NO CB 16-3700 SET# I ADDRESS 2706 Inverness APN 208-112-4600 This plan check review is complete and has been APPROVED by the Planning Division By Chris Sexton A Final Inspection by the Planning Division is required fl Yes No - You may also have corrections from one or more of the divisions listed below. Approval - - - from these divisions may be required prior to the issuance of a building permit. .. Resubmitted plans should include corrections from all divisions. 1 - - ' This plan check review is NOT COMPLETE. Items missing or incorrect are listed on . the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: dominic@luxhomebuilder.com - For questions or clarifications on the attached checklist please contact the following reviewer as marked: Al - PLANNING - -, - - ENGINEERING FIRE PREVENTION 760-602 4610 760-602-2750 760-602-4665 Chris Sexton Chris Glassen Greg Ryan 760-602-4624 760-602-2784 760-602-4663 Chris.Sexton@carlsbadca.gov Christopher.Glassen@carisbadca.gov Gregory.Ryan@carisbadca.gov Gina Ruiz . ValRay Marshall Cindy Wong 760-602-4675 - 760-602-2741 760-602-4662 -Gina.Ruiz@carisbadca.gov VaiRay.Marshail@carisbadca.gov Cynthia.Wong@carisbadca.gov - - Linda Ontiveros Dominic Fieri -• - • - - . 760-602-2773 760-602-4664 - Linda0ntiveros@carlsbadca.gov Dominic.Fieri@carisbadca.gov ;.S, • . 55• %S4 •• • 1 ••• -•. - • Plan Check No. CB 16-3700 Address 2706 Inverness Dr Date 9-29-16 Review # 1 • - Planner Chris Sexton Phone (760) 602-4624 APN: 208-112-46-00 Type of Project & Use: addition Net Project Density: 1.0 DU/AC Zoning P-C General Plan R4 Facilities Management Zone 1 1 CFD (in/out) # Date of participation: Remaining net dev acres (For non-residential development Type of land use created by this permit 4 REVIEW # V.2 3 ' Legend Item Complete LI Item Incomplete - Needs your action - • Li Li Environmental Review Required: YES LI NO LI TYPE DATE OF COMPLETION Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval LI Discretionary Action Required YES LI NO LI TYPE APPROVAL/RESO NO DATE PROJECT NO. .4! OTHER RELATED CASES: Compliance with conditions or approval? If not state conditions which require action Conditions of Approval Li .Li Coastal Zone Assessment/Compliance . Project site located in Coastal Zone? YES El NO El - CA Coastal Commission Authority? YES El NO El If California Coastal Commission Authority Contact them at — 7575 Metropolitan Drive Suite 103 San Diego CA 92108-4402 (619) 767-2370 1 Determine status (Coastal Permit Required or Exempt) . El LI . Habitat Management Plan Data Entry Completed? YES LI NO LI If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds Activity Maintenance enter CB# toolbar Screens HMP Fees Enter Acres of Habitat Type impacted/taken UPDATE') Li LI Anclusionary Housing Fee required YES Li NO LI (Effective date of Inclusionary Housing Ordinance — May 21 1993) . Data Entry Completed? YES Li NO Li (NP/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct, -. Housing Y/N Enter Fee UPDATE') V For construction of inclusionary units email notification provided to HNS9 YES Li NO Li (Email Susan Steinkemp in HNS with project number and contact info) Li Li Housing Tracking Form (form P-20) completed YES Li NO Li N/A Li S S I ! S• . . - P-28 _t - • • S. - • • S • Page 2 of 3 • 07/11 — . . • 4 - •- - -• . . - 5;s - - - Jt •. ,. I,• - •.. * . - '.Sit Plan: Li Li Li Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements existing and proposed structures streets existing street improvements right of- way width dimensional setbacks and existing topographical lines (including all side and rear ' yard slopes). Provide legal description of property and assessor's parcel number. City Council Policy 44— Neighborhood Architectural Design Guidelines LI LI 1 Applicability YES E) NO LI LI R. 2.' Project complies YES E] NOD Zoning: • Li Li- LI 1. Setbacks: Village K of Calavera Hills MP - dev stds go back to 21.45 - PUD Front -'Residence: Required 10 Shown 10 Front - Garage Required 20 Shown - . . Interior Side: Required 6.4' Shown 1 Street Side: Required 10' Shown 10.1 Rear Required 14 Shown LI LI 2 Accessory structure setbacks N/A - '..• - .,, •. Front: Required Shown _____ - Interior Side Required Shown ,. Street Side Required Shown Rear Required Shown Structure separation Required Shown - .... - ., LI LI LI 3 Lot Coverage Required >60% Shown Li Li 4 Height single-story Required >30 Shown >30 ELi arçing: Spaces Required Shown (breakdown by uses for commercial and industrial projects required) - Residential Guest Spaces Required Shown .111.0 LI Additional Comments 1) Please provide the lot coverage on sheet P0.1. The lot coverage .• .• cannot exceed 60% for single story homes. 2) Please show the dimension from the front property line to garage to ensure there is the required 20 foot front yard setback. 3) The site - plan is not to scale. - -.1 ,---._ -•--..•.-- - - -. .- OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE , .*- -,--. .- ;- .,• -:.- • .-- --. t • - - 47 -- _T- -. * • S j --4 - 4 4 P28 Page 30f3 07111 .4 •. -- * S : -• - (?iity '.arisbacLcommunty & Economic Development . .: . 0 • j1i 2011 CERTIFICATION OF SCHOOL FEES PAID : ':.: f . . ' RLSA C : . This form must be completed by. the City, the applicant, and the appropriate scho' 'ed to the ILL City prior. to.. issuing 'a building permit. The City will not issue any building permit iiThout a completed school fee•• form. . . . . Project No & Name Carlsbad Unified School District . .. . 6225 El Camino Real Plan Check No.: CB 163700 , Carlsbad CA 92009 Phone: (760) 331-5000 Project.Address: .2706 INVERNESS DR Assessor's Paräel No: 2081124600 .. . . . Encinitas Union School D'iàtrict 101 South Rancho Santa Fe Rd Project Applicant: .. . TRUST MIDDLETON GLENN P&ROCIO LIVING T Encinitas, CA 92024 (Owner Name) :. .. . . Phone: (760) 944-4300 x1166' Residential Square Feet San Dieguito Union H S District 0 . ....... . 684 Requeza Dr. . New/Additions.874 Encinitas CA 92024 ..... p'.. . . . .... - .. .. ..• Phone: (760) 753-6491 Ext 5514 Second Dwelling Unit (By Appt Only) Commercial Square Féèt: . . : •: San Marcos Unified Sch. District.. New/Additions: . . . .. 255 Pico Ave Ste. 100 .. .. - . . . . San Marcos, CA 92069 .City Certification: City. of Carlsbad Building Division Date: 01/10/2017 Phone: (760) 290-2649 Contact: Nancy Dolce (By Appt.only) certification of: 'Applicant/Owners. The person executing this declaration ("Owner") certifies under penalty of perjury that (1) the information provided above is correct and true to the - best of the Owner's knowledge, and that the Owner will file an amended certification of Vista Unified School District payment and pay the additional fee if Owner •requests an increase in the number. of 1234 Arcadia Drive dwelling' units or square -footage' after the building' permit is issued or if the initial Vista CA 92083 determination of units or square footage is found to be incorrect, and that (2) the Owner is Phone: (760) 726-2170 x2222 the owner/developer of the above described project(s), or that the person executing this . declaration is authorized to sign on behalf of the Owner. . . -. . : •: •. SCHOOL DISTRICT SCHOOL FEE CERTIFICATION '• : .. . •, .. •. (To be completed by the school district(s)) •. THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED. rsin'ed, . being duly' authorized by the applicable School District, certifies that the developer, builder, or - owner has satisfied. the, obligation for school facilities. This is to certify that the applicant listed on page 1 has paid all , amounts or completed . other- applicable school, mitigation determined by the School District. The City may issue building permits for this project. Signature of Authorized School District Official: " ( - Lk Title: -tt'-'_'A..A Date: ) ) Name of School District CARLSBAD UNIFIED SCHOOL DISTRICT Phone bab EL CANIINO HEAl. CARLSBAD, CA 92009 . •. . Building Division (f'_••'. 1635 Faraday Avenue 1, Carlsbad, .CA 92008 1 760-602-2719 760-602-8558 fax I bui