Loading...
HomeMy WebLinkAbout2709 JACARANDA AVE; ; CB153943; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 12-18-2015 Residential Permit Permit No: CB153943 Building Inspection Request Line (760) 602-2725 Job Address: 2709 JACARANDA AV CBAD Permit Type: RESDNTL Sub Type: RAD Status: ISSUED Parcel No: 2551050200 Lot #: 0 Applied: 11/13/2015 Valuation: $20,693.00 Constuction Type: 5B Entered By: SLE Occupancy Group: Reference #: Plan Approved: 12/18/2015 # Dwelling Units: 0 Stucture Type: Issued: 12/18/2015 Bedrooms: 0 Bathrooms: 0 Inspect Area: - Orig PC #: Plan Check #: Project Title: DELOSSANTOS: 452 SF INTERIOR REMODEL /1 REMOVE PORTION OF WALL BETWEEN ENTRY & KITCHEN, REBUILD KITCHEN, REMOVE 5 WINDOWS, INSTALL 1 DOOR & 4 WINDOWS Applicant: Owner: ANNE PARIZEAU DELOSSANTOS LOUIS S&KAMERON 5304 ONTARIO ST 2709 JACARANDA AVE OCEANSIDE CA 92056-1810 CARLSBAD CA 92009 760-201-3347 Building Permit $212.16 Meter Size AddI Building Permit Fee $0.00 AddI Red. Water Con. Fee $0.00 Plan Check $148.51 Meter Fee $0.00 AddI Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount , $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $2.69 PFF (3105540) $0.00 Park in Lieu Fee $0.00 PFF (4305540) , $0.00 Park Fee $0.00 License Tax (3104193) $0.00 LFM Fee $0.00 License Tax (4304193) $0.00 Bridge Fee $0.00 Traffic Impact Fee (3105541) $0.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541) $0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL ' $43.00 Renewal Fee $0.00 ELECTRICAL TOTAL $46.00 Add'l Renewal Fee $0.00 MECHANICAL TOTAL $0.00 Other Building Fee $0.00 Housing Impact Fee $0.00 HMP Fee $0.00 Housing lnLieu Fee $0.00 Pot. Water Con. Fee $0.00 Housing Credit Fee $0.00 Meter Size Master Drainage Fee $0.00 AddI Pot. Water Con. Fee $0.00 Sewer Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 Green Bldg Stands (SB1473) Fee $1.00 Fire Sprinkler Fees $0.00 Green Bldg Stands Plan Chk Fee $0.00 . TOTAL PERMIT FEES $453.36 Total Fees: $453.36 T tal Payments to Date: $453.36 Balance Due: $0.00 I B 1 a FINAP OVLL Inspector: ¶ Date: / ', / i,14 Clearance: NOT1E Ree take F'dIj10E ar c your rqed includes the "irr4iorc c fee4dedkatici reservations, or other exactionshereafter collectively referred to "fees'exia" Yc*Yheve 90 daysfrom the date this nit es issued to est irrsiticn of these feestexactions If you pest theii you rust follow the pest pxedures set forth in GDmTirnant Cede Section 6020(a), and file the pi ctest and any other requ red infaneticn with the City KUiager for pessng in a iaewth Carisbal Mi,id Cede Sedici 3.(x3O. Failtxe to trrdyfc&wUt pixaire iII her any sutisegient legal action to attack review, set aside, void, or annul their irxarition. You are hereby RJRfl-ER NO11RED that ,u.ir right to protest the specified feestexactions DOES NOT APPLY toeter and seer connection fees and capacity changes, nor planning, zoning, graring or other sirrilar application processing or service fees in oriinedai Wi, this project. NOR DOES ITAPAY to any THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0 PLANNING ENGINEERING 0 BUILDING FIRE [-]HEALTH HAZMATIAPCD C(City of Cailsbad Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: buildingcarlsbadca.gov www.carlsbadca.gov' Plan Check No. Qj5 Cj Est. Value 2( Plan Ck. Deposit Date \\/i/ gt. SWPPP I JOB ADDRESS '2. 7 (2 O i(.c t c SUITE#/SPACEC/UNITC APN - - - CT/PROJECT # LOT B PHASE B B OF UNITS B BEDROOMS B BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE 0CC. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) ThY' — reM\J( (oeaiJ IU41) rf.&e u./ 1er ka JZ5 _72,0 iZXISTIN SE PROPOSED USE GARAGE (SF) PATIOS (SF) DjSF) I FIREPLACE ksD#. NO AIR CONDITIONING I YES ENO FIRE SPRINKLERS YESENP APPLICANT NAME iL3...h r$nary Contact . —pot PROPERTY OWNER NAME ct to e, ADDRESS •3oq- ()V'4XIO ADDRESS 2-7O 'sJQc4r&t'4A A-vc€ CITY / ST 11 CITY STATE ZIP fl FAX . PHONE 12 EMAIL & EMAIL DESIGN PROFESSIONAL CONTRACTOR BUS. NAME ADDRESS ADDRESS CITY STATE ZIP CITY STATE ZIP c_it PHONE FAX PHONE , 'i-?of67 FAX EMAIL EMAIL ' I h .< I STATE LIC. B STATE LIC.# QBJ6Q'3 I CLASS I .4' I CITY BUS. LICe 17-iii97-0 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to Construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). e000OcoøcJ Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: El I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. [111 I have.and will maintain workers' compens tio as required by Section 3700 of the Labor Code, for the perform e work for which this permit is issued. My workers' compensation insurance carrier and policy n ber'ere: Insurance Co. cy No. Expiration Dale is section need not be completed if th permit is for one hundred dollars ($100) or less. Certificate of Exemption: I certify that in the performance of the work for which mill is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure work compe n overa unlawful, and shalt subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, dama s s dod for S n 3706 of the Labor code, Interest and attorney's fees, CONTRACTOR SIGNATURE , 0 AGENT DATE I hereby affirm that lam exempt Contra "License Law for the following reason: [] I, as owner of the pro POK or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). [] I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section ______________Business and Professions Code for this reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0Yes DNo ((have/have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): I plan to provide portions of the work, bull have hired the following person to coordinate, supervise and provide the major work (include name / address /phone /contractors' license number): I will provide some of the work, bull have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): .PROPERTY OWNER SIGNATURE []AGENT DATE Is the applicant or future building occupant required to submit a business plan, utely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 Yes o Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 Yes çI'4rd IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. (' 'n I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address . (T I certifythat I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comptywith all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter un the above mentioned property for inspection purses. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. 031-IA: M OSHA permit is required for excavations over 50' deep and deriioltiion or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void it the building or work authorized by such permit is not commenced within 180 days from the date of such permit or it the building orwortc auth9r, uch permit is suspended or abandoned at any time after the work is commenced for a period of 160 days (Section 106.4.4 Uniform Building Code). ,APPLICANT'S SIGNATURE . . DATE '- / Inspection List Permit#: CB153943 Type: RESDNTL RAD DELOSSANTOS: 452 SF INTERIOR REMODEL II REMOVE PORTION OF WALL Date Inspection Item Inspector Act Comments 03/11/2016 89 Final Combo - RI 03/10/2016 89 Final Combo PY AP 03/03/2016 89 Final Combo - RI AM PLEASE 03/03/2016 89 Final Combo MC CO NOTICE. 01/25/2016 84 Rough Combo MC AP INTERIOR KITCHEN WALLS AND 'CEILING LIGHTING AT LOWER FLOOR 01/20/2016 84 Rough Combo MC NR 01/15/2016 11 Ftg/Foundation/Piers PY AP 01/15/2016 17 Interior Lath/Drywall PY AP 01/15/2016 18 Exterior Lath/Drywall PY AP 01/13/2016 13 Shear Panels/HD's MC PA 01/12/2016 13 Shear Panels/HD's MC NR iTS STOP, 9:00 AM 01/12/2016 13 Shear Panels/HD's MC NR 2ND STOP, 1PM 01/12/2016 16 Insulation MC PA EXTERIOR WALLS ONLY 01/11/2016 84 Rough Combo MC PA EXT. WALLS ONLY. MINOR PICK UP. 12/29/2015 18 Exterior Lath/Drywall MC NR COMPLETE FRAME AND SHEAR. 12/24/2015 17 Interior Lath/Drywall MC CO NO ACCESS. 12/22/2015 21 Underground/Under Floor MC AP NEW KITCHEN SINK WASTE TO P.O.C. 12/22/2015 31 Underground/Conduit-Wirin MC AP CONDUIT ONLY TO KITCHEN ISLAND. Monday, March 14, 2016 Page 1 of 1 EsGil Corporation In Partnership with covernmentfdr Bui&uing Safety DATE: December 17, 2015 JURISDICTION: Carlsbad PLAN CHECK NO.: 153943 PROJECT ADDRESS: 2709 Jacaranda Ave. SET: III X LICANT S. N REVIEWER U FILE PROJECT NAME: De Los Santos Residence Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially cômpl'y with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. Lii The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: _-. Telephone #: Date contacted: - (b eerson Email: Mail Telephone Fax In REMARKS: Set Ill consists of only sheets Al and A2. Those sheets must be slip-sheeted into Set II. By: Kurt Culver Enclosures: EsGil Corporation LI GA LI EJ [1 MB [I] PC 12/11/15 9320 Chesapeake Drive, Suite 208 • San Diego, California 92 123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In Partners flip with covernment for Bui(&ng Safety DATE: December 4, 2015 U,APPLICANT JURIS. JURISDICTION: Carlsbad U PLAN REVIEWER U FILE PLAN CHECK NO.: 15-3943 SET: II PROJECT ADDRESS: 2709 Jacaranda Ave. PROJECT NAME: De Los Santos Residence Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. LIII The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Anne Parizeau EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Anne Parizeau Telephone #: 760-201-3347 D/te con1tacted: 2 +-(by: rY Email: AnneTheArchitectgmail.com au *eIephone Fax In Person LII REMARKS: By: Kurt Culver Enclosures: EsGil Corporation L] GA [I] EJ [1] MB LI Pc 12/1/15 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 15-3943 December 4, 2015 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. PLANS Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). THIS WILL BE VERIFIED WITH THE FINAL PLANS. 4. The plans call for the existing FAU to be relocated to the attic. Please provide documentation to show that the existing FAU is listed for installation in an attic. Also, isn't the current FAU vertical and now it will be laid flat in the attic? YOU CANNOT TAKE THE [VERTICAL] FAU, TURN IT FLAT, AND PUT IT IN THE ATTIC (UNLESS YOU CAN PROVIDE DOCUMENTATION FROM THE MANUFACTURER THAT SHOWS THIS IS AN ACCEPTABLE INSTALLATION). Carlsbad 15-3943 December 4, 2015 MISCELLANEOUS 13. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes El No i:i THE PLANS NOW SHOW AN INSTANTANEOUS WATER HEATER. THE FOLLOWING APPLIES: Please include a gas pipe sizing design (isometric or pipe layout) for all gas loads. The gas pipe sizing for a tank type water heater shall be based upon a minimum 199,000 Btu gas input rating. Energy Standards 150.0(n). The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kurt Culver at EsGiI Corporation. Thank you. 2 EsGil Corporation In Partnership with government for Building Safety DATE: November 24, 2015 U PLICANT Yj URIS. JURISDICTION: Carlsbad 7U PLAN REVIEWER U FILE PLAN CHECK NO.: 15-3943 SET: I PROJECT ADDRESS: 2709 Jacaranda Ave. PROJECT NAME: De Los Santos Residence Remodel LIII The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. El The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LIII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Anne Parizeau LII EsGil Corporation staff did not advise the applicant that the plan check has been completed. Z EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Anne Parizeau /Kate 7 ,,,16 tacted: EMaiI Fax In Person LIIIREMA : / By: Kurt Culver EsGil Corporation [:1 GA LIEJLJMB LIPc Telephone #: 760-201-3347 Email: AnneTheArchitectgmail.com Enclosures: 11/17/15 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 15-3943 November 24, 2015 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 15-3943 JURISDICTION: Carlsbad PROJECT ADDRESS: 2709 Jacaranda Ave. FLOOR AREA: n/c STORIES: 2 HEIGHT: n/c REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 11/13/15 DATE INITIAL PLAN REVIEW COMPLETED: November 24, 2015 DATE PLANS RECEIVED BY ESGIL CORPORATION: 11/17/15 PLAN REVIEWER: Kurt Culver FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2013 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC, 2012 UPC, 2012 UMC and 2011 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section. etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad 15-3943 November 24, 2015 . PLANS Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). THIS WILL BE VERIFIED WITH THE FINAL PLANS. Glazing in the following locations should be shown on the plans as safety glazing material in accordance with Section R308.4: a) Glazing adjacent to a door where the nearest vertical edge of the glazing is within a 24" arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60" above the walking surface. i) Window F by Door 3? The plans call for the existing FAU to be relocated to the attic. Please provide documentation to show that the existing FAU is listed for installation in an attic. Also, isn't the current FAU vertical and now it will be laid flat in the attic? Show the minimum 30" deep unobstructed working space in front of the attic installed furnace. Section CMC Section 904.10.3. The access opening to attics must be large enough to remove the largest piece of mechanical equipment and be sized not less than 30" x 22". CMC Section 904.10. Note that passageway to the mechanical equipment in the attic shall be unobstructed, have continuous solid flooring not less than 24 inches wide, and be not more than 20 feet in length from the access opening to the appliance. CMC Section 904.10. Carlsbad 15-3943 November 24, 2015 Show a permanent electrical receptacle outlet and lighting fixture controlled by a switch located at the entrance for furnaces located in an attic. CIVIC Section 904.10. Specify on the plans whether the existing house was built before or after 1994. For additions or improvements to a residence built before 1994, note on the plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons of water per flush, urinals that use more than one gallon of water per flush, showerheads that have a flow capacity of more than 2.5 gallons of water per minute, and interior faucets that emit more than 2.2 gallons of water per minute) shall be replaced. Certification of compliance shall be given to the building inspector prior to final permit approval. California 513407. Please submit Title 24 documentation to show compliance with the energy standards. The structural calculations call for shear walls at the upper floor (Line 1), but the plans don't show anything? MISCELLANEOUS To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes L11 No U 14. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kurt Culver at EsGil Corporation. Thank you. Carlsbad 15-3943 November 24, 2015 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 15-3943 PREPARED BY: Kurt Culver DATE: November 24, 2015 BUILDING ADDRESS: 2709 Jacaranda Ave. BUILDING OCCUPANCY: BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Remodel 20,693 Air Conditioning Fire Sprinklers TOTAL VALUE 20,693 Jurisdiction Code ICb IBY Ordinance I Bldg. Permit Fee by Ordinance V I $212.161 Plan Check Fee by Ordinance V I $137.901 Type of Review: E Repetitive Fee r ri Repeats EJ Complete Review D Other LI Hourly EsGil Fee Structural Only Hr. @ * I $118.811 Comments: Sheet. 1 of 1 macvalue.doc + PLANNING DIVISION Development Services BUILDING PLAN CHECK Planning Division CITY OR APPROVAL 1635 Faraday Avenue CARLSBAD P-29 (760)602-4610 www.carIsbadca.ov I DATE: 11/16/15 PROJECT NAME: INTERIOR REMODEL PROJECT ID: PLAN CHECK NO: CB153943 SET#: ADDRESS: 2709 JACARANDA AV APN: This plan check review is complete and has been APPROVED by the PLANNING Division. * By: GINA RUIZ A Final Inspection by the PLANNING Division is required E Yes Z No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT cOMPLETE. Items missing or incorrect are listed on the attached checklist: Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: ANNETHEARCHITECT@GMAIL.COM For questions or clarifications on the attached checklist please contact the following reviewer as marked: .. PLANNlNG ENGINEERING FIREPREVENTION V I 760-6024610k / 7606022750 - 7606024665 - - _ Chris Sexton Chris Glassen Greg Ryan - 760-602-4624 760-602-2784 760-602-4663 Chris.Sexton@carlsbadca.gov Christopher.Glassen@carlsbadca.gov Gregorv.Ryan@carIsbadca.gov Gina Ruiz ValRay Marshall Cindy Wong 760-602-4675 760-602-2741 760-602-4662 Gina.Ruiz@carIsbadca.gov ValRay.Marshall@carlsbadca.gov Cynthia.Won@carIsbadca.ov Veronica Morones Linda Ontiveros Dominic Fieri 760-602-4619 760-602-2773 760-602-4664 Veronica.Morones@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Dominic.Fieri@carIsbadca.gov Remarks: NO CHANGES TO EXISTING GARAGE OR FOOTPRINT Page 1 of 2 11/24/15 SIMPLY STRONG. E N G. I N E E R I N G 4020 30th St. San Diego, CA 92104 Evan Coles, P.E. (858) 346-7734 evan@simplystrongeng.com Project: De Los Santos Residence Address: 2709 JACARANDA AVE. CARLSBAD, CA 92009 Correction Responses November 24, 2015 Project #: 15-183 Correction : Please disregard page 8 of the original calculations. The shearwall analysis for the 2 nd floor shearwalls do not apply, we only used the analysis to determine the 2" floor load as required for shearwall design at the 1st floor. Revision: Floor beam FB-2 has been revised, and FB-3 removed. See additional calculations and updated plans. OFESS,o C77258 Or-EXP 06/30/17 rn DIGITALLY SIGNED Page 2 of 2 11/24/15 1 • • '. File D:\TEMPEN-1lSANT0S-1.EC6 u. 1pe Simple earn ENERCALC, INC. 1983-2015, Build:6.15.10.6, Ver:6.15.10.6 Description: FLOOR BEAMS revised WoodBeam Design.: B IIiiTTIIITITTTTT 1 Calculations per 2012 NDS IBC 2012 CBC 2013 ASCE 7 10 BEAM Size: 7x9.25, Parallam PSL, Fully Braced Using Allowable Stress Design with ASCE 7-10 Load Combinations, Major Axis Bending Wood Species: iLevelTrussJoist Wood Grade: ParallamPSL2.OE Fb - Tension 2,900.0 psi Fc - PrIl 2,900.0 psi Fv 290.0 psi Ebend- xx 2,000.0 ksi Density 32.210 pcf Fb - Compr 2,900.0 psi Fc -'Perp 750.0 psi Ft 2,025.0 psi Eminbend - xx 1,016.54 ksi Applied Loads Beam self weight calculated and added to loads Unit Load: D = 0.290, Lr 0.290 k/fl, Trib 1.0 ft Unit Load: 0 = 0.0140, L 0.040 klft, Trib 7.50 ft Unif Load: D = 0.0070 k/fl, Trib= 8.0 ft Design Summary Max fb/Fb Ratio = 0.287; fb Actual 831.06 at 7.750 ft in Span Fb Allowable: 2$0000 psi Comb Run (LL) Max fv/FvRatio = 0.308: 1 fv : Actual : 89.38 psi at 7.750 ft in Span # 1 Fv : Allowable: 290.00 psi 7.750 ft 4.250 ft. 7x9.25 _____________________________________________________________________ Load Comb: +D+L+H, LL Comb Run (LL) Max Deflections Max Reactions (k) D L Lr S W E H Downward L+Lr+S 0.078 in Downward Total 0.166 in Left Support 1.26 1.16 1.12 Upward L+Lr+S -0.046 in Upward Total -0.022 in Right Support 4.32 2.79 2.69 Live Load Defi Ratio 1298 >360 Total Defi Ratio 614 >240 PadFtg: JF-3 1 q=1506 psf - D(L43Qj )+Lr(2690 )+L( J) + W( + E( = Gov. Load: D+0.75L+0.75Lr = V(144* 8430 / 1500 )= 28.4 Mm. Square Dimension Use: t30]"Sqr. x 12 " Deep with (4) [j Bars Ea. Way 9,800 # Total Load 8430 # Factored Load rrrg 90%