HomeMy WebLinkAbout2710 ARLAND RD; ; CB041372; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Building Inspection Request Line (760) 602-2725
Residential Permit Permit No: CB041372 02-1 4-2005 am&y
NOTICE Please take NOTICE that approval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as 'feesfexactions ' You have 90 days from the date this permit was issued to protest imposition of these feesfexactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified feesiexactions DOES NOT APPLY to water and sewer connection lees and capacity
changes nor planning zoning, grading or other similar application processing or sewice fees in connection with this project NOR DOES IT APPLY to any , feeslexactions of which YOU have oreviouslv been aiven a NOTICE similar to this, or as to which the statute of limitations has Dreviouslv otherwise exDired
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
2710 ARLAND RD CBAD
RESDNTL SubType: RAD
1561303300 Lot #: 0
$1 1,742.00 Construction Type: NEW
Reference #:
0 Structure Type:
0 Bathrooms: 0
FRY RES 114 SF STAIRWAY/ ENTRY
Applicant:
WORTHING INC, B. A.
SUITE #201
690 CARLSBAD VILLAGE DR
CARLSBAD, CA 92008
61 9-729-3965
Status: ISSUED
Applied: 04/26/2004
Plan Approved: 0211 4/2005
Issued: 02/14/2005
Entered By: SB
Inspect Area:
Orig PC#:
Plan Check#:
Owner:
FRY FAMILY TRUST 06-1 8-01
P 0 BOX 4577
CARLSBAD CA 9201 8
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'l Pot. Water Con. Fee
Recl. Water Con. Fee
$1 15.09
$0.00
$74.81
$0.00
$0.00
$1.17
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
Meter Size
Add'l Recl. Water Con. Fee
Meter Fee
SDCWA Fee
CFD Payoff Fee
PFF
PFF (CFD Fund)
License Tax
License Tax (CFD Fund)
Traffic Impact Fee
Traffic Impact (CFD Fund)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing InLieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
TOTAL PERMIT FEES
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00 $0.00
$0.00
$0.00
$20.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$21 1.07
Total Fees: $21 1.07 Total Payments To Date: $74.81 Balance Due: $1 36.26
BU DTNGPLANS O2'14/05 0002 01 02
STORAGE CGP 136 26 ATTACHED
Insoector: & Clearance:
FOR OFFICE USE ONLY
PLAN CHECK NO.fiq/J 7 'z
EST. VAi,z-
Plan Ck. Deposit
Validated By 9
Date ~-,7~~!~ 7~lca) - CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
Leoal DescriDtion Lot No. Subdivision NamelNumber Unit No. Phase No. Total # of units
(Sec. 7031.5 Business issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
Policy No. 07% Expiration Date J-4=
S SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS IS1001 OR LESS)
is unlawful, and shall subject an amployer to criminal penalties and civil fines up to one hundred ation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
0 ith wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion. the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
0
1.
2.
3.
I, as owner of the property or my emp
I am exempt under Section
I personally plan to provide the major labor and materials for construction of the proposed property improvement. YES ON0
I (have I have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number I contractors license number):
Business and Professions Code for this reason:
4.
number I contractors license number):
5.
of work):
PROPERTY OWNER SIGNATURE DATE
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type
E THI
licant
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
YES 0 NO
EN
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citv of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEOUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is k authorized by such permit is suspended or abandoned at any time after the work is
APPLICANT'S SIGNATURE DATE 4)0/&
WHITE: File YELLOW: Applicant PINK: Finance 0
City of Carlsbad Bldg Inspection Request
For: 08/3 1 /2005
Permit# CB041372
Title: FRY RES 1 14 SF STAIRWAY/ ENTRY
Description:
Type: RESDNTL SubType: RAD
Job Address: 2710 ARLAND RD
Suite: Lot 0
Location:
APPLICANT WORTHING INC, B. A.
Owner: FRY FAMILY TRUST 06-1 8-01
Remarks:
Total Time:
CD Description Act Comment
19 Final Structural
29 Final Plumbing
Inspector Assignment: RB
Phongz
Inspect
Requested By: TERESA
Entered By: CHRISTINE
1 39 Final Electrical
49 Final Mechanical
Associated PCRs/CVs
CV040190 CLOSED H- CONSTRUCTION W/OUT A PERMW, & BACK FLOW PREVENTER
Date
08/08/2005
08/08/2005
07/27/2005
07/26/2005
07/25/2005
07/22/2005
0712 1 I2005
0711 812005
0711 812005
0711 512005
0411 412005
03/31/2005
03/24/2005
InsDection Historv
Description
17 Interior LatNDrywall
18 Exterior LattVDrywall
13 Shear PanelsIHDs
13 Shear PanelsIHDs
13 Shear PanelsIHD's
13 Shear PanelslHD's
13 Shear PanelslHD's
16 Insulation
34 Rough Electric
84 Rough Combo
11 FtgIFoundationIPiers
1 1 FtglFoundatiodPiers
11 FtgIFoundatiodPiers
Act
AP
AP
AP
co
PA
CA
CA
AP
AP
AP
AP
CA co
lnsp Comments
JM
JM
RB COMPLETED
RB NOACCESS
RB EXTERIOROK
RB
RB BYTERESA
RB
RB
PY
RB EXPOSED EXISTING FTG AND SLAB. ENGINEER APPROVED
RB
RB 1106-F-4 EXPOSE WORK WITHOUT PERMIT - SEE NOTICE AlTACHED
City of Carlsbad Bldg Inspection Request
For: 04/14/2005
Permit# CB041372 Inspector Assignment: RB
Title: FRY RES 114 SF STAIRWAY/ ENTRY
Description:
Type: RESDNTL SubType: RAD
Job Address: 2710 ARLAND RD
Suite: Lot 0
Location:
APPLICANT WORTHING INC, B. A.
Owner: FRY FAMILY TRUST 06-18-01
Remarks:
Total
CD
11
Phone: 7607293965
Inspector:
Time: Requested By: TERESA
Entered By: CHRISTINE
Description Act Comment
Ftg/Foundation/Piers &&- &p ‘;Jew Qp9- ep/:
t
Associated PCRs/CVs
Inspection History
Date Description Act lnsp Comments
03/31/2005 11 Ftg/Foundation/Piers CA RB
CV040190 CLOSED H- CONSTRUCTION W/OUT A PERMF, & BACK FLOW PREVENTER
03/24/2005 1 1 FtglFoundationlPiers CO RB 1106-F-4 EXPOSE WORK WITHOUT PERMIT - SEE NOTICE ATTACHED
JOB 23-1 0
1J I -,M . %:- SHEET NO. TH&A, INC.
3628 Lynoak Drive CALCULATED BY
Clarernont, CA 91711 CHECKED BY OATE
Suite 104 I
- SCALE
City of Carlsbad Bldg inspection Request
For: 03/24/2005
Permit# CB041372 Inspector Assignment:
Title: FRY RES 114 SF STAIRWAY/ ENTRY
Description:
Type: RESDNTL SubType: RAD
Job Address: 2710 ARLAND RD
Suite: Lot 0
Location:
APPLICANT WORTHING INC, B. A.
Owner: FRY FAMILY TRUST 06-18-01
Remarks:
Phone: 7607293965 w Inspector:
Total Time: Requested By: TERESA
Entered By: CHRISTINE
CD Description Act Corn nt
11 Ftg/Foundation/Piers co (LG t # .r) /!?&OX@ &# / /c&,
PJ,/fl4 4- &2’M~, fice
Associated PCRs/CVs
InsDection History
Date Description Act lnsp Comments
CV040190 CLOSED H- CONSTRUCTION W/OUT A PERMIT; & BACK FLOW PREVENTER
BUILDING DEPARTMENT
OTICE (760) 602-2700
1635 FARADAY AVENUE
/
DATE 3227-03 TIME
FOR INSPECTION CALL (760) 602-2725. RE-INSPECTION FEE DUE? 0 YES
FOR FURTHER INFORMATION, CONTACT
PHONE
Qp CODE ENFORCEMENT OFFICER
PAGE 61
Tel: (760) 720-7125
Fax (760) 720-71 10
March 23, 2005
B.A. Warthing, Inc P.Q. Box 1041 Carlsbad, CA 92008
Re: Special Inspection
27 10 Arlund Carlsbad, CA
Dear Sirs,
The installation of seveli (7) 518" threaded rods 12' into the foundation was
observed at 1O:OO a.m. on Wednesday, March 23,2005. The installation was done in accordance with the instructions on the tube of Simpson epoxy 1,C.B.O.
#ER5279, plan detail, and standard building praclices.
Sliotlld you have questions regarding this matter please contact me at
760.720.71 25.
Bill Van Tassel CBO #2832
ACI #049694 ICC #O57O410
EsGil Corporation
In PartnersKip with Government for QuiCdng Safety
DATE: July 9, 2004
JURISDICTION : Carlsbad
PLAN CHECK NO.: 04-1372
0 PLAN REVIEWER
0 FILE
SET: I1
PROJECT ADDRESS: 2710 Arland Rd.
PROJECT NAME: Fry Residence Addition and Remodel w
0
0
0
I7
IXI
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction’s building codes.
The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant’s copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Fax #:
REMARKS:
Mail Telephone Fax In Person
By: Bill Elharraras Enctosu res:
Esgil Corporation
GA MB 0 EJ PC 7/1/04 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
EsGil Corporation
In partnership with Government for Suiliiing safety
bay 6,2004
JURI SDl CTl ON: Carlsbad
PLAN CHECK NO.: 04-1372
0 FILE
SET: I
PROJECT ADDRESS: 2710 Arland Rd.
PROJECT NAME: Fry Residence Addition and Remodel
0
0
w
I7
w
0 w
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction’s building codes.
The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant’s copy of the check list has been sent to:
Brooks Worthing
P.O. Box 1041, Carlsbad, CA. 92018
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Brooks Worthing
Date contacted: S/b /ov (by: (?ed
Mail Telephone Fax‘ In Person
REMARKS:
By: Bill Elizarraras Enclosures:
Telephone #: 760-729-3965
Fax #: 760-729-0784
Esgil Corporation 0 GA MB 0 EJ c] PC 4/27/04 tmsmtl.dot
9320 Chesapeake Drive, Suite 208 San Diego, California 92123 (858) 560-1468 Fax (858) 560-1576
Carlsbad 04- 1372
May 6,2004
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 04-1372 JU Rl SDl CTION: Carlsbad
PROJECT ADDRESS: 2710 Arland Rd.
FLOOR AREA: 114 sq.ft. Dwelling Add'n STORIES: 2
HEIGHT: 17'
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: ESGIL CORPORATION: 4/27/04
DATE INITIAL PLAN REVIEW PLAN REVIEWER: Bill Elizarraras
COMPLETED: May 6,2004
DATE PLANS RECEIVED BY
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinance by the Planning Department, Engineering Department, Fire
Department or other departments. Clearance from those departments may be required prior to
the issuance of a building permit.
Present California law mandates that residential construction comply with the 2001 edition of
the California Building Code (Title 24), which adopts the following model codes: 1997 UBC,
2000 UPC, 2000 UMC and 1999 NEC (all effective 11/1/02).
The above regulations apply to residential construction, regardless of the code editions adopted
by ordinance.
The following items fisted need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a COPY) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked UP list when you submit the revised plans.
Carlsbad 04- 1372
May 6,2004
PLANS
1.
2.
3.
4.
5.
6.
7.
8.
9.
Please make all corrections on the original tracings, as requested in the correction list.
Submit two sets of plans for residential projects. For expeditious processing, corrected
sets can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700.
The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering
and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculationsheports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments.
All sheets of plans must be signed by the person responsible for their preparation.
(California Business and Professions Code).
Plans, specifications and calculations shall be signed and sealed by the California state
licensed engineer or architect responsible for their preparation. Specify expiration date
of license. (California Business and Professions Code).
Glazing in the following locations should be of safety glazing material in accordance with
Section 2406.4:
a) Fixed or operable panels adjacent to a door where the nearest exposed edge of
the glazing is within a 24-inch arc of either vertical edge of the door in a closed
position and where the bottom exposed edge of the glazing is less than 60 inches
above the walking surface.
Guardrails (Section 509.1):
a)
b)
c)
Shall have a height of 36".
Shall be detailed showing adequacy of connections to resist the horizontal force
prescribed in Table 16-B.
Openings between railings shall be less than 4". The triangular openings formed
by the riser, tread and bottom element of a guardrail at a stair shall be less than
6.
Every dwelling unit shall be provided with heating facilities capable of maintaining a
room temperature of 70 degrees F at 3 feet above the floor in all habitable rooms. Show
basis for compliance. UBC, Sec. 31 0.1 1.
Show stud size and spacing. Maximum allowable stud heights: Bearing wall: 2 x4 and 2
x 6 max. IO'; Non-bearing: 2 x 4 max. 14', 2 x 6 max. 20'. Table 23-IV-B. Design all
studs exceeding these limitations.
If required, show size, embedment and location of hold down anchors on foundation
plan. Section 106.3.3.
If hold downs are required, note on plan that hold down anchors must be tied in place
prior to foundation inspection. Section 108.5.2.
Carlsbad 04- 1372
May 6,2004
IO. Show the following on the plans for the required braced wall panels. If the requirements
of braced wall panels in conventional light frame construction are not possible, provide
design calculations from a licensed Engineer or Architect.
a) Show on the plans the location, length and type of braced wall panel as per UBC
Section 2320.1 1.3 and Table 23-IV-C-1.
i)
ii)
Braced wall panels shall start at not more than 8’ from each end of a
braced wall line.
In all Seismic Zones, braced wall panels in one story structures shall be
installed at each end and not more than 25’ on center along the length of
the braced wall line.
b)
c)
Interior braced wall panels shall extend to the roof or floor diaphragm level.
Any braced wall panel required by Section 2320.1 1.3 may be replaced by an alternate braced wall panel. UBC Section 2320.1 1.4. For alternate braced wall
panels in one story buildings, show compliance with the following on the plans:
i) Minimum braced panel length is 2’-8” in width and a maximum height of IO’-”’.
ii) Each braced wall panel is sheathed on at least one face with 3/8” plywood sheathing nailed with 8d common or galvanized box nails per 23-
11-8-1 and blocked at all plywood edges.
A minimum of two anchor bolts installed in accordance with
Section1 806.6 between hold down devices.
An approved hold down device fastened to the foundation and capable of
providing an uplift capacity of not less than 1,800 pounds is provided at
each panel end.
The foundation that supports the braced panels is continuous across the
entire length of the braced wall line and reinforced with a minimum of one
# 4 bar top and bottom.
In the first story of a two story building, each alternate braced wall panel shall be
as described above except that the plywood sheathing shall be provided on both
faces, three anchor bolts are to be installed, and hold down devices at panel
ends with uplift capacity of not less that 3,000 pounds provided.
Continuous footings shall be provided under interior braced wall lines. See
Section 2320.5.6 for possible exceptions.
iii)
iv)
v)
d)
e)
To speed up the review process, note on this list (or a copy) where each correction item has
been addressed, Le., plan sheet, note or detail number, calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located in the plans.
Have changes been made to the plans not resulting from this correction list? Please indicate:
Yes 0 No 0
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite
208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan
review for your project. If you have any questions regarding these plan review items, please
contact Bill Eharraras at Esgil Corporation. Thank you.
c
@
Carlsbad 04- 1372
May 6,2004
VALUATION AND PLAN CHECK FEE
PLAN CHECK NO.: 04-1372
DATE: May 6,2004
JURISDICTION: Carlsbad
PREPARED BY: Bill Elizarraras
BUILDING ADDRESS: 2710 Arland Rd.
BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION: VN
Jurisdiction Code Icb By Ordinance
1994 UBC Building Permit Fee
I
V
1994 UBC Plan Check Fee 4
Type of Review:
0 Repetitive Fee 3 Repeats
Complete Review Structural Only
Other
~our~y n Hour*
Esgil Plan Review Fee 0
I $115.091
I $74.81 I
Comments:
Sheet 1 of 1
macvalue.doc
BUILDING PLANCHECK CHECKLIST
HECK NO.: CB 0 L/l LY 72
3 42 PROJECT DESCRIPTION:
ASSESSORS PARCEL NUMBER: i 66 .- 1 3 0 -3 -2 EST. VALUE: 1 I, YL I
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submittal; therefore any changes to these items after
this date, including field modifications, must be reviewed by this office to insure continued
conformance with applicable codes. Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build.
A Right-of-way permit is required prior to
construction of the following improvements:
I
DENIAL
Please see the attached report of deficiencies
marked with 0. Make necessary corrections to plans
or specifications for compliance with applicable
codes and standards. Submit corrected plans andlor
specifications to this office for review.
By: Date:
By: Date:
By: Date:
FOR OFFICIAL .s USE ONLY
UTHORIZATION TO ISSUE BUILDING PERMIT:
By: Date:
-\ I
// \\ \ 2 ENGINEERING DEPT. CONTACT PERSON
Nm~e: JOANNE JUCHNIEWICZ
City of Carlsbad Dedication Checklist
Improvement Application
Improvement Checklist
Address: 1635 Faraday Avenue, Carlsbad, CA 92008
Phone: 1760) 602-2775
Future Improvement Agreement
Grading Permit Application
Grading Submittal Checklist
Right-of-way Permit Application
Right-of-way Permit Submittal Checklist
and Information Sheet
Sewer Fee Information Sheet
CFD INFORMATION
Parcel Map No:
Lots:
Recordation:
Carlsbad Tract:
1
A-4
Rev. 7lluoO
r
BUILDING PLANCHECK CHECKLIST / 3RD SITE PLAN
0 0 1. Provide a fully dimensioned site plan drawn to scale. Show:
A. North Arrow F. Right-of-way Width & Adjacent Streets
B. Existing & Proposed Structures G. Driveway widths I
C. Existing Street Improvements H. Existing or proposed sewer lateral
D. Property Lines I. Existing or proposed water service
E. Easements J. Existing or proposed irrigation service
0 0 2. Show on site plan:
A. Drainage Patterns
1. Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course.
2. ADD THE FOLLOWING NOTE: “Finish grade will provide a minimum positive
drainage of 2% to swale 5’ away from building.”
B. Existing & Proposed Slopes and Topography
C. Size, type, location, alignment of existing or proposed sewer and water service
(s) that serves the project. Each unit requires a separate service, however,
second dwelling units and apartment complexes are an exception.
D. Sewer and water laterals should not be located within proposed driveways, per
standards.
.’
a( 0 0 3. Include on title sheet: / A. Site address
B. Assessor’s Parcel Number
C. Legal Description
For commercial/industriaI buildings and tenant improvement projects, include:
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
2 Rev. 7I1uM
BUILDING PLANCHECK CHECKLIST
3d DISCRETIONARY APPROVAL COMPLIANCE
0 4a. Project does not comply with the following Engineering Conditions of approval for
Project No.
0 4b. All conditions are in compliance. Date:
DEDICATION REQUIREMENTS
0 5. Dedication for all street Rights-of-way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $15,000, pursuant to Carlsbad
Municipal Code Section 18.40.030.
Dedication required as follows:
Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 %" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax.
Dedication completed by: Date:
IMPROVEMENT REQUIREMENTS
6a. All needed public improvements upon and adjacent to the building site must be constructed at time of buildins construction whenever the value of the 0
construction exceeds $75.000, pursuant to Carlsbad Municipal Code Section 18.40.040.
Public improvements required as follows:
Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the
Rev. 1-
BUILDING PLANCHECK CHECKLIST
1ST 2ND 3RD
checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit.
Improvement Plans signed by: Date:
0 0 0 6b. Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or
current grant deed on the property and processing fee of $310 so we may
prepare the necessary Future Improvement Agreement. This agreement must be
signed, notarized and approved by the City prior to issuance of a Building permit.
!
Future public improvements required as follows:
0 0 6c. Enclosed please find your Future Improvement Agreement. Please return
agreement signed and notarized to the Engineering Department.
Future Improvement Agreement completed by:
Date:
fl 0 6d. No Public Improvements required. SPECIAL NOTE: Damaqed or defective
improvements found adiacent to buildinq site must be repaired to the satisfaction of the Citv Inspector prior to occupancy.
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
11.06.030 of the Municipal Code.
a 0 7a. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities (cut, fill import, export).
0 7b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached. NOTE: The Gradina Permit must be issued and rounh aradinq
approval obtained prior to issuance of a Buildinq Permit. .
Grading Inspector sign off by: Date:
7c. Graded Pad Certification required. (Note: Pad certification may be required even
if a grading permit is not required.)
H1WORD\WCS\CHKLST\BUldirq Planohsch CUaI Fon (Generic 7-1COO).doc 4 Rev 7/14!03
BUILDING PLANCHECK CHECKLIST
000
000
uno
7d .No Grading Permit required.
7e. If grading is not required, write “No Grading” on plot plan.
MISCELLANEOUS PERMITS
8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-way and/or
private work adjacent to the public Right-of-way. Types of work include, but are
not limited to: street improvements, tree trimming, driveway construction, tying
into public storm drain, sewer and water utilities.
Right-of-way permit required for:
9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153,
for assistance.
Industrial Waste permit accepted by:
Date:
10. NPDES PERMIT
Complies with the City’s requirements of the National Pollutant Discharge
Elimination System (NPDES) permit. The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas. Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
fees are attached
No fees required
WATER METER REVIEW
12a. Domestic (potable) Use
Ensure that the meter proposed by the owner/developer is not oversized.
Oversized meters are inaccurate during low-flow conditions. If it is oversized, for
the life of the meter, the City will not accurately bill the owner for the water used.
0 All single family dwelling units received “standard” 1” service with 5/8” service.
5 RW. 7I1W
BUILDING PLANCHECK CHECKLIST
IST 2ND 3RD
0 If owner/developer proposes a size other than the “standard”, then
owner/developer must provide potable water demand calculations,
which include total fixture counts and maximum water demand in gallons
per minute (gpm). A typical fixture count and water demand worksheet is
attached. Once the gpm is provided, check against the “meter sizing
schedule“ to verify the anticipated meter size for the ’unit.
0 Maximum service and meter size is a 2” service wifh a 2” meter.
0 If a developer is proposing a meter greater than 2”, suggest the
installation of multiple 2” services as needed to provide the anticipated
demand. (manifolds are considered on case by case basis to limit
multiple trenching into the street).
[7 0 0 12b. Irrigation Use (where recycled water is not available)
All irrigation meters must be sized via irrigation calculations (in gpm) prior
to approval. The developer must provide these calculations. Please follow
these guidelines:
1. If the project is a newer development (newer than 1998), check the recent
improvement plans and observe if the new irrigation service is reflected on
the improvement sheets. If so, at the water meter station, the demand in
gprn may be listed there. Irrigation services are listed with a circled “I”,
and potable water is typically a circled “W. The irrigation service should
look like:
n STA 1+00 Install 2” service and
1.5: meter (estimated 100 gpm)
2. If the improvement plans do not list the irrigation meter and the
service/meter will be installed via another instrument such as the building
plans or grading plans (w/ a right of way permit of course), then the
applicant must provide irrigation calculations for estimated worst-case
irrigation demand (largest zone with the farthest reach). Typically, Larry
Black has already reviewed this if landscape plans have been prepared,
but the applicant must provide the calculations to you for your use. Once
you have received a good example of irrigation calculations, keep a set for
your reference. In general the calculations will include:
0 Hydraulic grade line
0 Elevation at point of connection (POC)
0 Pressure at POC in pounds per square inch (PSI)
Worse case zone (largest, farthest away from valve
Total Sprinkler heads listed (with gpm use per head)
Include a 10% residual pressure at point of connection
3. In general, all major sloped areas of a subdivision/project are to be
irrigated via separate irrigation meters (unless the project is only SFD with
no HOA). As long as the project is located within the City recycled water
I
IST 2ND 3RD
BUILDING PLANCHECK CHECKLIST
service boundary, the City intends on switching these irrigation
serviceslmeters to a new recycled water line in the future.
c] 0 c] 12. Irrigation Use (where recycled water is available)
1. Recycled water meters are sized the same as the irrigation meter above.
2. If a project fronts a street with recycled water, then they should be
connecting to this line to irrigate slopes within the development. For
subdivisions, this should have been identified, and implemented on the
improvement plans. Installing recycled water meters is a benefit for the
applicant since they are exempt from paying the San Diego County Water
Capacity fees. However, if they front a street which the recycled water is
there, but is not live (sometimes they are charged with potable water until
recycled water is available), then the applicant must pay the San Diego
Water Capacity Charge. If within three years, the recycled water line is
charged with recycled water by CMWD, then the applicant can apply for a
refund to the San Diego County Water Authority (SDCWA) for a refund.
However, let the applicant know that we cannot guarantee the refund, and
they must deal with the SDCWA for this.
0 0 0 13. Additional Comments:
7 Revv. 7l14hX
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Phone (760) 602- qd~ l<
cilities Management Zone:
CFD (inlout) #-Date of participation: Remaining net dev acres:
(For non-residential development: Type of land used created by this
permit: 1 223 Circle One
Leqend: Item Complete 0 Item Incomplete - Needs your action
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary ActZon Required:
APPROVAURESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
!jii
Environmental Review Required: YES - NO~TYPE
YES - NO x TYPE
~~
Coastal Zone AssessmenVCompliance
NO
Project site located in Coastal Zone? YES-
CA Coastal Commission Authority? YES-
If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103,
San Diego CA 921 08-4402; (61 9) 767-2370
Determine status (Coastal Permit Required or Exempt):
If NO, complete Coastal Permit Determination Form now.
Coastal Permit Determination Log #:
Coastal Permit Determination Form already completed? YES- NO-
Follow-Up Actions:
1)
2)
Stamp Building Plans as "Exempt" or "Coastal Permit Required (at minimum Floor Plans).
Complete Coastal Permit Determination Log as needed.
Y lnclusionary Housing Fee required: YES - NO -
(Effective date of lnclusionary Housing Ordinance - May 21, 1993.)
Data Entry Completed? YES __ NO - (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N,
Enter Fee, UPDATE!)
Site Plan:
H:V\DMIMCOUNTER\BldgPlnchkRevChklst RW 9/01
1. Provide a fully dimensional site plan drawn to scale. Show:. North arrow, property lines,
easements, existing and proposed structures, streets, existing Street improvements, right-of-way
width, dimensional setbacks and existing topographical lines (including all side and rear yard
slopes).
2. Provide legal description of property and assessor's parcel number.
Policy 44 - Neighborhood Architectural Design Guidelines
1. Applicability: YES NO k
2. Project complies YES NO
Zoning:
1. Setbacks: #/
Front: Required LO
Interior Side: Required .y Shown
Required Shown
Required *, Shown .-e
Street Side:
Rear:
Top of slope: Required Shown - 1
ry structure setbacks:
Required Shown Required Shown
t Side: Required Shown
Required Shown
Required Shown
3. Lot Coverage: Required 4 $!o 7 Shown yo
/ /
4. Height: Required d 30 Shown
5. Parking: Spaces Required 2- Shown hr*N
Residential Guest Spaces Required Shown
(breakdown by uses for commercial and industrial projects required)
I.
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER 'q DATE @b4z/Say
H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01
STRUCTURAL CALCULATIONS
PROJECT NO.: 06-34
Lt
JOB 93-IO AYPdHBC .@le. &hBM,
SHEET NO A OF
DATE 6-23- 04- TH&A, INC.
3628 Lynoak Dnve CALCULATED BY
Claremonc CA 91711 CHECKED BY DATE
TEL./FAX: (909) 621-5008
Suite 104
1
. Structural calculations are for the analysis or design of primary structural systems
and elements. Other connections and attachments of non-structural elements, or
systems are the responsibilities of the architectural designer unless they are shown
otherwise by the Engineer. . This calculations and specifications are for this address only Any other use is not
allowed and Engineer shall not be responsiile for the unauthorized use . Architectural designer is responsible for aU applicable sketching details on plans
which should represent required fia.ming conditions, detiuls needed for construction
SHEET NO OF
CALCUUTED BY DATE 6d23,@4
CHECKED BY DATE
SCALE
TH&A, INC.
3628 Lynoak Drive Suite 104
Claremont. CA 91711
TELJPAX: (909) 621-5008
TH&A, INC.
3628 Lynoak Drive
Suite 104 Claremont. CA 91711
CALCULATED BY I
CHECKED BY DATE
SCALE b
... gwLdeQdAlh h-.
I -
WS indicates Western Species Western Species may include
Douglas fir, lodgepole pine western hemlock or white fir
Design values shown are for 100% load duration
13/4" 1.8E WS MICROLLAM'" LVL
(2) F,, shall not be increased for duration 01 load
77 u--- 7
1.8E WS MICROLLAM'" LVL
ALLOWABLE DESIGN STRESSES
Srear -07- LS c1 e as: c t, G = ''2 F3C 25
GENERAL NOTES:
9 Lareral support 01 beam Compression edge is required at intervals of 24" O.C. or closer . See NER-126 lor addi!ional design ~nformalion
Modulus 01 elasticity E = 1 8 x 10" psi
Flexural stress
Compression perpendicular Io grain
parallel to glue line
Compression parallel to grain
Horizontal shear perpendicular
F, = 2600 psi'
F,_ = 750 psi
F, I = 2460 psi
to glue line Fv = 285 psi
(1) For 12 inch depth For others, multiply by
(2) F,_ shall no1 be increased for duration of load
'' 136 [TI
13/4'' 2.OE WS PARALLAM' PSL 211/i6" 2.OE WS PARALLAM@ PSL
I Moment (ft. Ibs.) '. I 6 530 I 9 950 ! 13 580 I 17 475 121 830 I
I Shear(Ibs3 I 32151 40201 47351 5.4151 60901
IMoment of Inertla (In*)l 125 I 245 i 400 I 595 1 850 1 I Weight (Ibs./lin.tt,)' I 5 2 i 6 51 7 71 881 981
Moment (n. Ibs.)
Shear(lbs.)
13 055 1 i 9 900 127 160 34 955 43 665
54301 80351 9475 10825 12 180
Moment of Inertia (In4) 250 490 I YO0 1 I95 1 700
Weight(Ibs./lln.ft.) 1041 1301 153 175 I97
19.585 129.855 140.740 152,430 165 495 I
Microllam LVL & Parallam" PSL - Allowable Holes
- A D a iirirr 01 1r1e ,argest mie in1 nmmi ..
DO NOT% nolch or drill ncies In
Parallam. PSL excepl as inaicareo
in char1 and illusIration
- GENERAL NOTES:
' The Aiiowea Hole Zone .n this cPar1 IS suitable tor umformiy loaded beams using
f?i2~1'~-n- 'oaos lor any iaoles lisled in this guide For olnei load conditions or hole
:cri gdrar.ons Slease coti:ac! your Trus Joisl MacMiilan Representative
11 'w3'c 'liar 3ne noie IS io 3e CUI fi briiiii ilie !ensin 01 the uncut beam between
:?lei ::us' 3e a ii',~:'~imwii c: IN ':e in? atar~wer 01 [he largest ?ole
hcr'i?g-,ar mies art. ;ici ~lii~s*ec
L
- - -,31t: . ever5 rqL8,e ~caii~rai ili'aljsis
ROUND HOLE CHART
Page 26
-- Rd A: &dOQ TH&A, INC. SHEETNO & OF
3628 Lynoak Dnve CALCULATED BY DATE L-23- 04 Suite 104 I --
Claremont, CA 91711 CHECKED BY DATE
br
SHEETNO A OF
3628 Lynoak Dnve Suite 104 CALCULATED BY DATE 6 - 23d 0 4 THM, INC.
Clarcmonr, CA 917 11 CHECKED BY DATE
3628 Lynoak Drive Suite 104 Claremonc CA 9171 1
JOB
SHEET NO OF
CALCULATED BY DATE &Z3*0& I
CHECKED BY OAT€
SCALE
JOB
SHEET NO OF
CALCULATED BY .+ DATE 6
CHECKED BY DATE
I
THM, INC.
3628 Lynoak Drive Suite 104 Claremont, CA 9 17 1 1
SHEET NO. OF
CHECKED BY DATE
3628 Lynoak Drive Suite 104 Claremont, CA 917 11
SHEET NO. OF
CHECKED BY DATE
SHEET NO. c-4 OF
3628 Lynoak Dnvc CALCULATED BY DATE -4 e 2 3-04 THM, mc.
Sulk 104 I .-
Claremont, CA 91711 CHECKED BY DATE
I
SHEAR WALL SCHEDULE
SYM MATERIAL NAILING SHEAR
VALUE
TRANSFER
NAILING
ANCHOR
BOLTS A A A A
1R" Gyp Bd
Unblocked
5d Cooler Nails @ 7" OC
F.N. & E.N.
50UIFT 16d @ 12" OC or
A35 @I 32" OC 5/8"x10" @ 48" oc (1)
5/8" Gyp EM
Unblocked
6d Cooler Nails @ 7" OC F.N. & E.N.
50bIFT 16d @ 12" OC or
A35 @ 32" OC
5/8lxlO"@ 48" OC (1)
In" Gyp Bd
Unblocked
5d Cooler Nails @ 4" OC F.N. & E.N.
16d @ 8" OC or
A35 @ 32" OC
5/8"x10" @ 48" OC (1)
518" Gyp Bd
Unblocked
6d Cooler Nails @ 4" OC
F.N. & E.N.
16 GA Staples 6" OC
Top & Bottom Plates, Edges
& Field of Shear Panel
751m 16d @ 8" OC or
A35 @ 32" OC
5/8?10" @ 48" OC (1)
180XFT 16d @ 8" OC or
A35 @ 32" OC
5/8"x10" @ 48" OC (1) 7/8" stucco w/
Paper Backed
Wire Lath
3/8" Struct I1
C-D or C-C
8d @ 6" OC E.N. & B.N.
12" OC F.N. 16d @ 6" OC or
A35 @ 24" OC
5/8?10" @ 24" OC (1)
Plywood
3/8" Struct I1
C-D or C-C
Plywood
3fi" Struct I1
C-D or C-C
-A ' 5/8%10" @ 24" OC (1) 8d @ 4" OC E.N. & B.N.
12" OC F.N. (3)
16d @ 4" OC or
A35 @ 16" OC
8d @ 3" OC E.N. & B.N.
12" OC F.N. (3)
490#/.Fr 11% 8 3" OC or
A35 @ 12" oc 5B"xlO" @ 16" OC (1)
Plvwood
5/8"x12!' @ 12" OC (1) 8d Q 2" OC E.N. & B.N.
12" OC F.N. (2) (3)
64O#/FT 16d @ 2" OC or
A35 @ 9" oc 3B" Struct I1
C-D or C-C
Plywood
In" Struct I1
C-D or C-C
In" Struct I A C-D or C-C
Plywood
A 1W @ 3" OC E.N. & B.N.
12" OC F.N. (2) (3)
16d @ 3" OC or
A35 @I 12" oc 5/8"x10" @? 12" OC (1)
5/8"xl~'@ 8" OC (1) 1Od @ 2" OC E.N. & B.N.
12" OC F.N. (2) (3)
770#m 16d @ 2" OC or
A35 @ 8" OC Plywood
NOTE' (1) Spacing of anchor bolts and shear transfer nailing shall be reduced by half if shear wall materials are required on both
(2) Framing at adjoining panel edges shall be 3-inch nomimal or wider and nails staggered
(3) Where plywood is on both sides of wall, framing member for panel joints shall be 3-inch nomimalsr wider and nail
faces of wall.
on each side is staggered
PLm S(l3THINC
2x RIM JST. OR BLK'C.
A35 FRAMING ANCHOR PER SCHEDULE SPACED PER SCHEDULE 16d NN15 SPACED
PER SCHEDULE.
08L Toe PUTE
SHEAR TRANSFER W/ 2x4 BLOCKING -_ \
SHEAR TRANSFER W/
METAL CUPS
TABLE 23-11-8-1
3. 1" x 6' (25 mm x 152 mm) subfloor or lcss to each joist, face nail
4. Wider than 1" X 6" (25 mm X 152 mm) subfloor to each joist, face nail
2-8d
3-8d
1997 UNIFORM BUILDING CODE
.
TAB& 23-It-6-I-NAIUNO SCHEDULE
COHNECTION NAKINO'
3-8d I. Joist lo sill or girder, loenail
J 5. 2" (51 mm) subfloor lo joist or girder, blind and race nail 2- 1 6d
6. Sole plale fo joisl or blocking, typical face nail 16d at 16" (406 mm) O.C. 3-16d per 16' (406 rnm) Sole date to ioist or blocking. at braced wall panels
2. Bridzinn lo ioist, toenail each end 2-8d I
-
7. Top plate to stud, end nail 2- I (id
8. Stud io sole plate
9. Double studs; face nail
4-84 loenail or 2-16d, end nail
166 8124' (610 mni) O.C.
16d at 16" (406 rnm) O.C. 8-16d
3-8d
10. Doubled top plates, typical lace nail Double top plates, lap splice
12. Rlm /oh1 to top plate, loenail
14. Continuous header, two pieces
11. Blocking bclween Joists or rafters lo top plate, {oenail
8d a1 6' (152 mm) O.C.
2- 16d
16d a1 16" (406 mm) 0.c along each edge
13. Top plrles, laps and inlerseclions, face nail
IS. Ceiling joists lo plrlc, locnail 3-Rd
16. Continuous hcader lo stud, toenail 4-ad
17. Ceiling joisls, laps 'over partitions, face nail
18. CciIiny joists to parallel ruitcrs, racc nail
19. Rallcr lo plate, toenail
3-16d
3- l6d
3-8d
20. 1" (25 mm) brocc lo coch stud and platc, lncc nuil
21. 1" x 8" (25 mm X 203 mm) sheathing or less lo each buring, face nail ,
2-ad-
2-ad '
22. Wider lhan I" X 8" (25 mm X 203 mm) alienthing lo ench bearing, face nail 3-8d
23. Built-up corner studs
24. Built-up girder and beams
25. 2" (51 mm) plnnks
26. Wood slructurnl pnncls niid pnrticlchonrtl:2
16d.at24" (610 mm) O.C.
2Od PI 32" (813 sin) o.c. lit lop and bottom nnd xtaggcrcd 2-2lkl nt cnds mntl 111 cnch splicc
2-16d a1 cach bearing
1
d .. Nu. IG ga.q No. 11 ga.8 8d4 No. I(lga.y
'14" (6.4 mrn) 4d 1"
29. Interior paneling
'/e" (9.5 mm) hd"
Common or box nails may be used exccpl where otherwise staled. .
*Nails spaced at 6 inches (152 mrn) on center a1 edges, 12 inches (305 mm) at intermediate supporls except6 inches 152 mm) at all supporls where spans are 48 inches (1219 mm) or more. For nailing of wood structural panel and particleboard diaphragms and shear walls, re ! er to Sections 2315.3.3 and 2315.4. Nails lor wall sheathing may be common, box or casing. 'Common or deformed shank. '~ommon. SDefonned shank. 6Corrosion-resistanl siding or casing nails conforming to the requirements of Section 2304.3. 7Fasleners spaced 3 inches (76 mm) on cenler at exterior edges and 6 inches (152 mm) on cenler at intermediate supports. aConosion-resistanl roofing nails with 7/16-inch-diameier (11 mm) head and 11/2-inch (38 mm) length for l/z-inch (12.7 mm) shealhing and l3/4-inch (44 mm ) length for "h2-inch (20 rnm) sheathin conforming lo the requirements of Section 2304.3.
for Zs/,2-inch (20 mm) shealhing conforming to the requirements of Section 2304.3.
spaced 6 inches (152 rnrn) on panel edges, 12 inches (305 rnm) at inlermediate supports.
9Corrosion-resistanl slaples with nominal 5- /I6 inch (11 mm) crown and ll/s-inch (29 mm) length Cor 'Iz-inch (12.7 mm) sheathing and lllz-ilrh (38 mm) length
10Panel supporis al 16 inches (406 mrn) [20 inches (508 mm) if strength axis in the long direction of the panel, unless otherwise marked]. Casing or finish nails
IIPanel supporls a1 24 inches (GI0 rnm). Casing or finish nails spaced 6 inches (152 mm) on panel edges, 12 inches (305 mrn) at inlermedialc supporls.
2-282
..... . ... .. ... _._ .._.. . -
THBtA, INC.
Englneerlng and Code Consultants
125 West Mission Ave. Suite 201
Escondldo, CA. 92025
Tm1.z (760) 746-5112, Faxi (760) 741-0480 WAL8
1
2
3
4
S
t
2 3
4
I)
4 7 e
9
10
!
2
GENERAL t
ALL DE'TAILSt SECTYONS AND NOTES SHOWN ON STRUCTURAL DRAUINGS CIA€ INTENDED TO e.€ TYPICAL AND SHALL APPLY TO SIPIXLAA SITUATIONS ELSEUHEAE U. N. 1). ALL DESIGN AND CONSTRUCTION SHALL IN ACCORDANCE WtTW THE LATEST ADOPTED EDITION OF THE UNIFORM BUILDING CODE.
CILL ClMISSIW~S OR CONFLICTS bETWEEN THE VAAICWS ELERENTS CIF THE
UClRI( f NG ORAU f NCS AND/OR SPECIFICATICM SHALL t2E e.RCiUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENCItXER P.EFORE
PROCEEDING 'WITH ANY UORH INVI:ILVED,
CONTRACTOR TO PROVIDE ADEQUATE SHORING AND BRACING TO SUPPORT
ALL LOADS DUR INC CC~PJSTAUCTION. DURING CIINSTRVCTION AND Pff 1t:Iff TO THE INCORPORATION qf 9 ALL WAN-
GESI REVISIONSt MODIFICATIONS AND/OR DEVIATIONS FROW THE STRUCTURAL
DRAWINGS SHALL e.€ DROUGHT TO THE ATTENTIl:1N OF, AND OL).TAIN APPRQVAL FROM THE ARCHITECT, STRUCTURAL ENGINEER AND THE GOVERNING BUILDING 0 E PA R TI7EPJ 1.
LU?leER/FRAMIPJGt
ALL 2X HORIZONTAL RF/CLG LUMEXER "0 Fa€ MXN bFM2 UoNoO*
ALL 2X HORIZONTAL FLR LUMeER TO FIE: MIN DFSZ U,N,Oo
ALL GLVLAMS TO BE DF/DF COne 24F-V4 DRY USE U.N.0.
PLL 2X VERTICAL LURf?.ER TO e€ MIN DF M2 U.N.O.
ALL 4X C LARGER VERTICAL LUMeER TO e€ HIN DFWl U.N.O.
ALL 4x I LARGER HORIZONTAL LUM~ER TO MIN DF ~i U.N.O.
AU PLYWO TO eE BIN CD-cc STRUCT 11 OR CDX,,
VPICAL NAILING SCHEDULE ns PER wec z3-p.
CARRY ALL POSTS I Deoc STUDS DOWN TO FOUNDATIONS. eLoci( SOLID AS REQ'D FOR FULL eRG a FLR LINES, -4
BUILT-UP eEAMS: DgL $X tlEWRS TO ea€ FACE NAILED W/ MIN 16J a
12in OC STAGGERED TOP/MT. 3 OR HORE 2X UtlINATIONS TO BE CONN
112fn OIA Mel & WASHER HIN 8 2Sin OC STAGGERED TOPle-OT + 2 EA END
TH&A, INC.
Englneerlng and Code Consultants
125 Wcsl Ml.qnlon hvc. Sullc 201 OACEUCAT#O 8V OAT[
Cscondido, CA. 92025 WIOItO 8V DATl
Tot,: (700) 740-5112, Pax! (760) 741-0480 8CALi
1
2
3
1 2
3
4
1
2 3
4
3
&
CONCRETE:
ALL CONCRETE TO REACH HIrJ ULT COMPRESSIVE STRESS OF 2500 PSI
.r
a 28 DAYS U.N.O.
MASONRYZ .
CONC9ETE MASONRY UNITS TO NORMAL WEIGHT HOLLOW LOAD eEAR IPIG
TYPE CONFORMING TO ASTM C-90. MASONRY UNITS SHALL BK CLEAN AND FREE OF ALL SUBSTANCE THAT HIGHT ItlPAIR BOND AND SHALL EE STORE3
UNDER COVER ON THE JO&,
ALL CONCRETE MASONRY UNITS TO e.€ GRADE N-11 U.N.O.
MIN COMPRESSIVE STRENGTH OF ALL IIASC~NRY UNITS SHALL eo€ 1500 PSI.
TYPICAL TYPE 'PI' MORTAR1 1 PART CEMENT, 3-1/2 PARTS SAND1
1/4 PART LIME PUTTY, CONFORM W/ ASTM C-270. WATER CONTENT
SHALL e.€ MIN REIi' D FOR WORKING CQNSISTENCY. MIN 2000 PSI 4
G2OUT MIX SHALL e.E 1 PART CEMEPITi 5 PARTS SAND AND (OPTIONAL)
1/10 PART LINE PUTTY. ADD UP TO 2 PARTS PEA GRAVEL WHERE SPkCES
EXCEED ?ifl Mu!. =e DAY ULT STRENGTH OF GROUT SHALL eE 2000 PSI.
' USE SUFFICIENT LJkTER TO PRODUCE PWRING CONSISTENCE W/O SEGRE5ATION4
REINF STLt *.
LAP ALL MESH MIN 2 MODULES.
ALL REINF eAR9 SHALL BE ACCURATELY & SECURELY PLACED BEFORE
POURING CONC OR APPLYING Pb3RTAR OR GROUT.
STRUCT snr
ALL STEEL TO CONFORM TO ASTH-AJ6 VaN.0. DETAILING & FABRICATION PER AISC LATEST EDIT ON.
I&\$" N 0 ALL STEEL PIPES TO CONFORM TO ASTM A33 GRAD
c
ALL ~TWL 706 ~LUMEJ rz) COE?WPM TO CIWM ++ 0@"~&'6''F9f46K~r*
FASTENERS: ..
ALL CONNECTORS NOTED TO BE SIMPSON OR EQUIVALENT. ALL eOLTS TO BE M\rd ASTM-A307. * eOLT HOLESt flAX l/lbin LARGER'THAN BOLT DIA. #
ALL eOLTS eRG ON WOOD TO USE H. 1, WASHER UNDER H€AD C NUT.
LAG BOLTS8 LEAD HOLES FOR SHANK TO eE SAME AS SHANNI THREADED
ALL NAILS TO BE COflMON U.N.0. PORTION TO eE 60-70% OF SHANK DIA.
8 I
JOB TH&A, INC,
Engineering and Code Consultants
125 West Mission Ave. Suite 201
8WEET NO OF
CALCULATE0 BY DATE
Escondido, CA 92025 CHECKED BY DATE
8CALC Tel.: (760) 746-5112, Fax: (760) 741-0480
7
1 2
3
4
1
?* -
3
4
5
6
7
8
9
10
!1
FASTENERS:
USE FULL NAILING/BOLTING a ALL C9NNECTORS U.N.O.
FOUNDATIONS:
PROVIDE RIN CODE REQUIREMENTS FOR ALL FOUtJDATIONS U.N.O.
ALL CONTIISOLATED FTGS TO e€ PLACED MIN in INTO COMPETENT ERG SOIL 9R BEDROCK. ACQUISITION OF A SOILS REPORT IS RECOMMENDED FOR ALL JOE.
IF Nil SOILS REPORT IS AVAILABLE1 ASSUM'D SOIL TYPE t PaR5 VALUE
USED IN CALCULATIONS ARE SUBJECT TO BUILDING DEPT APPROVAL. ENG3 WILL NOT eE HKLD RESPSVJSIBLE FOR BLDG DEPT APPROVED VALUES
SEE FOUNDATION PLAN FOR ALLOWAe.LE SOIL BRC PRESSURE.
RETA IN I NG WALLS :
CONTRACTOR SHALL VE3IFY ALL DIRENSIONS & COFJDITTONS ON THE JOE.,
RES?ONSIS.ILITY FOR ACCURATELY DESCRIP-INC THE SITE CONDITIONS RESTS ON THE CLIENT. RNIEN CALCULATIONS ItlnEDIATFIY TO DETtRMINE
UHETHEG3 CONSIDE3ATION WAS GIVEN IN WALL DE5IG?J FOR ADJACENT FiGi
IF THEE5 IS ANY QWESTIOPd REGARDING THIS MATTER. VEI"!CLE OR e.ACHSLOPE SURCHARGES. CONTACT THIS OFFICE IMm9IATF'Y
IF Nc:) SOILS RE?ORT IS AVAJLABLE? ASSUPI'D SOIL TYPE C: PRG VALUE
USE3 IN CALCULATIONS ARE SUEJECT TO BUILDING DEPT APPROVAL.
VE3IFY INSPECTION REQUIREMENTS W/ eLDC DEPT PRIOR TO CONSTR.
SEE RtTAININC WALL SCI.IEDULE FOR ELOCK INSPECTION REBUIRE?lWTS.
ALL REAINING WALL FTGS TO EXTEND MIN in INTO COMPETENT eRG
SOIL AS DEFINE^ ey SOILS REFORT OR APPROVED STANDARD PRACTICE. RECOMMENDATIONS OF SOILS REPORT TO SUPERCEDE THIS \IN REQVIREKENT eonon OF PAD TO e.E MIN 57 FROM DAYLIC~T~ msuw IN A HORIZ
DIRECTION FROM THE NEAREST EOTTOM EDGE OF PAD.
PROVIDE EITHE2 A MIN 12in x 12in GRAVEl POCK= a BASE OF WL
WITH 4in DIA PVC PE3FORATED DRAIN PIPE T9 DAYLICKTI OR MIN 2 SQ IN WE? HOES a BASE OF WALL STEM TO ADJACENT GRADE a 48in OC.
BACKFILLING SHALL NOT eE STARTED FOR AT LEASTZt DAYS AFTER THE FILLING OF THE CELLS UITH GROUT0 .
BACKFILLING MUST eE THOROUGHLY TAMPED TO PRNENT FUR THE^^ S~ING.
DO NOT E*ACKFIU UNTIL ALL WORK HAS PASSED REB'D INSPECTIONS.
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL SHORING DURING CONSTRUCTION AS REB'D.
ALL eACKFILL MATEFI'IALS TO eE GRANULAR1 i.+. SAND3 GRAVEL? OR SOIL APPROVED BY PROJECT SOILS ENGINEER.
? SD i .EYHOtZ)ER COPY d STAT ... P.O. BOX 807, SAN FRANCtSC0,CA W 142-08ti i COMPENSATION INSURAN~E F N D CERTIFICATE OF WORKERS' COMPENSATION INSURANCE
ISSUE DATE: 01-01-2004 GROUP. PalCY NUMBER:
CERTIFICATE IO:
000046 0908775-2004 a
CERTlFlCATE EXPfRES: 61-01-2005 01-01 -~044/61-01-2005
CITY OF OCEANStDE, BUILOING DEPT. SO JOB: ALL OPERATIONS
OCEANSIDE CA, 92054 300 N. COAST HWY
This is to certify that we have issued a valid Workers' Compmsation insurance policy in h form approved by the California Insurance commissioner to the employer narned below for the policy period indicated.
This policy is not subject to cancellation by the Fund except upon ~drys' Advance written notic@ to the employer.
We will also give you 30 days' advance notice should this policy be cancelled Prior to its normal expiration.
This certificate of insurance is not an insurance policy and does not amend, extbnd or alter the coverage afforded by the wlicies listed herein Notwithstanding any requirement. term, or condition of my contract or other document with respect to which this certificate of insurance may be issued or may pertah, the msurance afforded by the policies described herein is subject to all the terms, exclusions and conditions of such policies.
I
AUTHORIZED REPRESENTATIVE PRf StOENT
EMPLOYER'S LIABILITY LIMIT INCLUDING DEFENSE CUSTS: $1, RENCE .
ENDORSEMENT R22685 ENTITfED CERTZFICATE HOLDERS' WTIa EPFtiCtIVE 01~01-2604 IS FORMS A PART OF THIS POLICY.
EMPLOYER LffiAL NAM6
B.A. WORTHING INC. PO BOX 1041
CARLSBAD CA 92018