HomeMy WebLinkAbout2710 LOKER AV WEST; ; CB063231; Permit12-04-2006 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB063231 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2710 LOKER AV W EST CBAD Tl - Sub Type 2090813100 Lot# $20,000 00 Construction Type Reference # VERIZON 20 KW GENERATOR FOR EXISTING CELL SITE COMM 0 NEW Applicant PERFORMANCE INSTALLATION 125 EAST COMMERCIAL ST ANAHEIM CA 92801 562-244-4679 Status Applied Entered By Plan Approved Issued Inspect Area Plan Check* PENDING 11/09/2006 KG Owner FRANZ-ATRIUM II L P 2710 LOKER AVEW #100 CARLSBAD CA 92010 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $17669 Meter Size $0 00 Add'l Reel Water Con Fee $11485 Meter Fee SO 00 SDCWA Fee $0 00 CFD Payoff Fee $420 PFF (3105540) $0 00 PFF (4305540) $0 00 License Tax (3104193) $0 00 License Tax (4304193) $0 00 Traffic Impact Fee (3105541) $0 00 Traffic Impact Fee (4305541) $000 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees HMP Fee TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $2000 $000 $000 $000 $000 $000 97 $31574 Total Fees $315 74 Total Payments To Date $11485 Balance Due $200 89 NO PLANS STORAGE ATTACHED Inspector FINAL APPROVAL Date /-Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020{a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 PROJECT INFORMATION FOR OFFICE USE ONLY PLAN CHECK NcLr/J^ EST VAL D&fftO Plan Ck Deposit Validated By Date l\~ J/_ Address {includ \ O £J_CA Business Name (aj this address) Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor s Parcel # 00 Use Proposed USB Description of Work SQ FT #of Stones of Bedrooms # of Bathrooms idizlf CrName ' ' Address ' City <3iU~ 'APPLICANT f^QiContractor! "S'Agent for Cohtractorf !-Q Owrw^lQ'Agent'for Owner ;,j|> „ '' N/flaJ/&afi(tf /^\A)°/}^ Sk &3*> Upland ne '-' Address (Citv State/Zip Telephone # Fax # State/Zip Telephone #Name Name Address City State/Zip Telephone ff •S^-sCONTRACTOR!:-"COMPANY NAME"*' F i '«"; "?JLT t , Sf ™B *1^ J.V. !";,>.> "^f 'JX'i > "!(rMl'"l" f X. •!!' 'vL ! , ' F7u-^''"-aVr fyS;i (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than fiva-hundred dollars [$50011 Name State License ft \ffllO£iie Address License Class City State/Zip City Business License # Irvine Designer Name State License # T lj? 7L/^? L/ Address City State/Zip Telephone a*-', WORKERS'/COMPENSATION; fl^?^ '"VrrjCC''1'^ flV!Lr,:»b f!!il'! "FTvTCs * sV ^:T!>^ r'"Vflt ^"H1^; ,&'&in•$',;,(. Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations Q I have and will maintain a certificate of consent to self-insure for workers compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued I have and will maintain workers compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is ed My worker s compensation insurance carrier and policy number are Insurance Company |TV\ (X \ €5.V] C, „ Policy No C l*-> V\J? U;? £7 I IU ^ Expiration Date_ thousand dollars (THIS SECTION NEED NOT BFCOMPLETED IF THE PERMIT (S FOR ONE HUNDRED DOLLARS l$100] OR LESS) Q CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees DATESIGNATURE •7 t\ OWNER-BUilDER DECL'AR^lON I hereby affirm that I am exempt from the Contractor sTLicense Law for the following reason D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor^} licensed pursuant to the Contractor's License Law) [H I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement Q YES QNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) I plan to provide portions of the work, but ! have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) 4 number PROPERTY OWNER SIGNATURE DATE COM^LETEJHIS SECTION FOR WOW-RES/DEfVTWtrBOltDING^ERWIlTS^ONLY «,''.!MS s I^LU,', W«;fellU5! ,'K ', ,» n'"RV, '< U,,,! ',! . *<»! ^^i^1™"^ & Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? G YES Q NO Is the applicant of future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES C] NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site7 Q YES Q NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT ¥' , t!co"NsfRuctiorj LENDING AGENCY », 7V; !t,' 1» „ I '., ^f!!r™ f T>''VJ ','r i'.li; >!' /' ,',' f,'!" > V1' V,[!7' tf' • ^ ? ill H <! , r f U ^', ^ ^'" i ^ I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code) LENDER'S NAME LENDER S ADDRESS (9! /J'APPLICANTJCERTIFICATION * |L S^fff1*, "V (SJ »J,u'IS«.""'".'...-' """ ^( !«' ~ ^""""' "4 ^""T1"' ^.' ^'^"JAUi'U" u,*"' ^T'''^"""^ ^' !" ^ I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building OtficiajAJnder the/fJroyisions of this Code shall expire by limitation and become null and void if the building or work aulhonzed by such permil is not commencgrlwithin 180j>ays from Ibfe date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is coijfrrj^n^tf'for a period fn 180 days/Spetion lOG^rfSprform Building Code) DATE ///ft File "YELLOW Applicant PINK Finance / APPLICANT'S SIGNATURE City ol Carlsbad Final Building Inspection Dept: Building Engineering Planning CMWD St Lite Eire Plan Check # Permit # Project Name CB063231 VERIZON 20 KW GENERATOR FOR Date Permit Type Sub Type 01/17/2007 Tl COMM EXISTING CELL SITE Address Contact Person Sewer Dist Inspected By Inspected Bv Inspected Bv Comments 2710LOKER STEVE CA hrtf&Vl' ' I /J'& £^f AVWEST Phone 7143180632 Water Dist CA Date , / Inspected A//ft Date Inspected Date Inspected / ^ s&f^ /sJ&A &/Z& A Lot 0 Approved &1^ Approved Approved Disapproved Disapproved Disapproved City of Carlsbad Bldg Inspection Request For 01/17/2007 Permit* CB063231 Title VERIZON 20 KW GENERATOR FOR Description EXISTING CELL SITE Inspector Assignment Sub Type COMM 2710 LOKERAVWEST Lot 0 Type Tl Job Address Suite Location APPLICANT PERFORMANCE INSTALLATION Owner FRANZ-ATRIUM II L P f^~*^ __ -a"*" Remarks a m please -final generator inspection Total Time Phone 7143180632 Inspector Requested By STEVE Entered By CHRISTINE CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act Comment fif Comments/Notices/Holds Date Associated PCRs/CVs Original PC# PCR01290 ISSUED ( AIRIUM !I, REVISE MASONRY WALL @ CXFERIOR S I AIR PCR01309 ISSUED ARHUM II - RELOCA I F flXVATOR SUMP DiSCHARGi: hROM INSIDE FO GUI SIDE PCR02064 ISSUED AIRIUM LI-REV ROOF MAI ER1AL, PCR02089 ABANDOND AIRIUM II CUR IAIN WALL SYSTEM Inspection History Description Act Insp Comments EsGil Corporation In Partnership untH government for Quitting Safety DATE 11/22/O6 Q ARRUQANT JURISDICTION City of Carlsbad a PLAN REVIEWER Q FILE PLAN CHECK NO 063231 SET I PROJECT ADDRESS Loker Ave. West PROJECT NAME Verixon Wireless McClellan The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person X) The applicant's copy of the check list has been sent to Nina Spangler Nina Spangler 1533 W 11th Street #23 (?) 125 E Commercial Street #B (?) Upland, CA 91786 Anaheim, CA 92801 . Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Nina Spangler (v-^1 Telephone # 714-318-1953 Date contacted (fllllotefoy \c— ) Fax # Mail -*^telephone^ Fax In Person REMARKS By David Yao Enclosures Esgil Corporation D GA D MB D EJ D PC 11/14 tmsmtldot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 City of Carlsbad O63231 11/22/06 GENERAL PLAN CORRECTION LIST JURISDICTION City of Carlsbad PROJECT ADDRESS Loker Ave. West DATE PLAN RECEIVED BY ESGIL CORPORATION 11/14 REVIEWED BY: David Yao PLAN CHECK NO' O63231 DATE REVIEW COMPLETED 11/22/06 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law * To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? Q Yes a NO City of Carlsbad O63231 11/22/06 Please make ail corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGiI Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGiI Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE: Plans that are submitted directly to EsGiI Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGiI Corporation is complete • PLANS 1- Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 editions of the California Building/Plumbmg/Mechanical Codes and the 2004 edition of the California Electrical Code, which adopt the 1997 UBC, 2000 UMC, 2000 UPC and the 2002 NEC 2 On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below • REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec 1701 of the Uniform Building Code ITEM REQUIRED? REMARKS • SOILS COMPLIANCE PRIOR TO FOUNDATION INSPECTION • FIELD WELDING • HIGH-STRENGTH BOLTS • EXPANSION/EPOXY ANCHORS • STRUCTURAL MASONRY • DESIGNER-SPECIFIED • OTHER 3 When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit. Please review Section 106 3 5 Please complete the attached form 4 Provide complete calculations to show the platform construction is adequate Section 1063 1 7 5 Provide calculation to show the existing framing is adequate to support the new platform City of Carlsbad 063231 11/22/06 6 Provide calculation to show the CMU enclosure wall is adequate • ADDITIONAL 7 UBC Section 107 2 requires the Building Official to determine the total value of all construction work proposed under this permit The value shall include all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other permanent equipment Please provide the designer's or contractor's construction cost estimate of all work proposed 8. Please refer to the following electrical items. 9 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc 10 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate' Q Yes a No 11 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation Thank you 4 ELECTRICAL PLAN REVIEW * 2002 NEC + PLAN REVIEWER: Morteza Beheshti 1 Show the existing available fault current (Isc) from the serving utility co 2 Please justify 10,000 ampere AlC level at new panel 3 Note on the single line diagram that all service disconnect devices shall be labeled as a "Service Disconnecting Means" All service disconnects must be grouped NEC 230- 70(b) City of Carlsbad O63231 11/22/O6 4 Please provide an existing and added electrical load analysis to justify the additional load on the service Note: If you have any questions regarding this electrical plan review list please contact Morteza Beheshti at (858) 560-1468 To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans City of Carlsbad 063231 11/22/06 City of Carlsbad Building Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No 063231 Job Address or Legal Description Loker Ave. West Owner Address You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect The Special Inspector is not authonzed to accept alternate materials, structural changes, or any requests for plan changes. The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet (over) City of Carlsbad O63231 '11/22/06 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: PLAN CHECK NUMBER: OWNER'S NAME: I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special mspector(s) as required by Uniform Building Code (UBC) Section 1701 1 for the construction project located at the site listed above UBC Section 106 3 5 Signed I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106 3 5 for the construction project located at the site listed above. Engineer's/Architect s Saal& Signature Hera Signed 1. List of work requiring special inspection: Q Soils Compliance Prior to Foundation Inspection n Field Welding C] Structural Concrete Over 2500 PSI Q High Strength Bolting E] Prestressed Concrete Q Expansion/Epoxy Anchors Q Structural Masonry Q Sprayed-On Fireproofing Q Designer Specified tH Other 2. Name(s) of individual(s) or firm(s) responsible for the special inspections listed above: A, B. C. 3, Duties of the special inspectors for the work listed above: A. B. C. Special inspectors shall check in with the City and present their credentials for approval prior ..to beginning work on the job site City of Carlsbad 063231 11/22/06 VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO O63231 PREPARED BY David Yao DATE' 11/22/06 BUILDING ADDRESS. Loker Ave. West BUILDING OCCUPANCY.TYPE OF CONSTRUCTION BUILDING PORTION cell site Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) cb Valuation Multiplier By Ordinance Reg Mod estimate VALUE ($) 60,000 60,000 $383.56 Plan Check Fee by Ordinance Type of Review i I Repetitive FeeRepeats Complete Review D Other i—i Hourly Structural Only Hour Esgil Plan Review Fee $249.31 $214 79 Comments Sheet 1 of 1 macvalue doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER a PAT! (Mfo-o£, RISIMNTIAL TINANT IMPROVEMENT « $10.000.00} PLA2A CAMNO RIAL CARHBAD COMPANY STORES VTLLAGIFAIRI CDMPura opna BUILDING OTHER pk/£.,£_ MCINEER DAT! OATI - — V*. POWER Industrial Generator On-Site Power Industrial Generator Set » 20kW Diesel : .Model • Emissions KD2CH Standby Rating 60 Hertz 20 kW (25 kVA) Prime Rating ; 60 Hertz 18kW(22.5kVA)i Heavy Duty Engine • Heavy duty, 4-cycle, desel engine, naturally aspirated, overhead valves, mdrect injection • Manual speed control governor • Meets EPA emissions standards for mobiie off-highway Alternator • Brushless,4^x^,syTichronous,4-leaddesjgn • Temperature rise standards meets Oass H insulation system Electronic Voltage Regulator • Encapsulated electronic voltage regdator precisely regulates the current into the excrter field • Vottage regulation of ±1 0% no toad to full load Full Load Acceptance • Accepts 100% of standby namepfate rating in one step, in compliance wrth NFFA, para 5-13 2 6 Cooling System a Ctosedarcuitpressur-zedsystemMtharr^entteirperatufBrating of40°C{104DF) Generator Control Panel • ICS-50™ microprocessor-based, digital control panel, vibration isolated and NFPA110 compliant • Liquid crystal cispiay screen with alphanumenc readout for display and programming • Selkiagnostic feature continuously verifies processing, memory circuits and input/output SWd and Housing • Generator available as skid-mount or sub-base tank mount design • Integral vibration isolators • Outdoor weather-protective or sound-attenuated housings m tseei oanery rack and battery cables Warranty • Engine-generator sets are covered by an express written 2-year/ 2000 hour banted warranty • Optional extended warranties available Agency Approval • UL2200 POWER Industrial Generator ALTERNATOR SPECIFICATIONS : Specifications" ••':'••.-- •;'.• •'.; v. - - -=•-•• i Manufacturer/Model TV** [Exeter Type Number of Leads \foKaga Regulator Insulation Maleral Temperature Rise Bearing, Type Coupling Coofng Atr \foiume Amorttsseur Windings Voltage Regulation (no toad to fuH toad) Singte Step Load Acceptance per NFPA 1 10 • • ,* MagnaPius Generator--; •.'•: Marallion 283PSL1516 4-Poie, Rotating Field Srushiess Shunt Excitation Design 12 Lead Broad flange. Reconnectabte SE350 Sotri State, Vols-per Heflz NEMA MGI-1 66 Class H 125"C, Standby Ratmg Single, Sealed Flexfoie Dtsk Type 250 dm Fu« +1% 100% of Rating 9 Comp*ant irth NEMA MGt-22, BS5000, CSA C22-2 IEC 24-1 standard, fur 'em- perature. ise • Sustaned snort-oicuff capabtfty allowifK) downstream -.oordindLiofi brea rs-3'a to 'i p without collapsing She generator field • Drp-pfoof, self-venting, amortsseuj windings • Epoxy impregnated windings wrtft tropical insulation for increased environmental protectcn arid long Kfe • Exceptional wavesnape and vollage balance 2/3 pitch ending to minimize nai- montc distortion • Sot(d-sfate, vo(s-pw hertz voltage 'eguiator with. ±1% no-load LO ru.J-ioad voltage regulation Amperage • ' ; Vottage . Piiase - . Wire . - . Amperage 12(V206Vbn J2£V240Vbl 277/480 Vo« 12tV240Vo» 3 3 3 1 -1 4 4 3 69 j 60 30 33 Engine APPLICATION DATA Fuel Engine Sp»CffKations Manufacturer Mdttel/Type Cylnder Arrangement Displacement Sore SWQfce CofnpressKm Ratio Piston Speed Cylrder Block Cylftder Head Cmnkstiaft BrSte Mean Effectire Pressure (BHEP) Rated RPM Max Power 9 Rated RPM (wift fan) Governor Type Frequency Re^ulatjon no load to fuN bad 50 H; • ' isuzu 4LE1PV024-cycte indirect npcton natural^ aspirated water cooled 4 !n-Lme ,^, 3 35 m (85 mm) 37em (96mm) 2151 1134 ft, tan (576m/sec) Cast iron Cast ifor overhead valves Ductte cast iron 104 pa [719 kPa) 1800 RPM 34 5 hp (25 7 hW} Mccrianicaf 5% under /aryng loads 'ram no load to 100% rated toad Frequency flegulaton Steady_Sfate Ait Cleaner Type ±05% o) mean value br constant toads from no toad to futf bad Dry Rating Gmdehnei STANDSY POWER Ratng corresponds to ISO Standard Fuel Stop Power Itisappficabtetor sjpptywg standby alectncal power at variable load n areas w#t well established etectrcal net- works >n Ihe event of normal utility power fa&jre No overload capaMrty s avaSabte toe the ratug PRIME POWER Ralmg corresponds'o ISO Sandard Power for awu^uous operation its apoficabte far 5uppfyng electncal power at Arabia cad for an unhnrted number of hours n stead of comrrercalty purchased po*er A10% overbad capability is available fer "hs rating SINGLE PHASE OUTPUT Broad large alternators can supply srgte phase output jp to 2/3 sel rated 3-phase kW at 1 OPF Refer to Amperage chart Fjftl System ' 50 Hz - • Fuel Injection Pump Make Recommended Fuel Total Fuel Flow Feed Pump Maximum Suction Head FuefFfler Bosdi/Zexel ASTM-D975 / No 2-O 634aal/hr(24UTiF) 1 64 feet (0 5 meter) ReplaceaiJte spin-on paper element typefiBer Exhaust Exhaust System' Exhaust Flow at Rated kW Exhaust Temperature at Rated kW Maximum Allowable Backpressure Heat Rejection To Exhaust Standby 1624 cfm (46 nWmin) StarKfcy 10004 °F (538-C) Standby TBD Engine Electrical Erigine Eiecrtrlcsi System '" r .:/":. '<••;".' '' , • "•"• '"'/' "•'•s.:.:-: Battery Charging ABernator Make Ground Type \fotts (DQ Ampere Rating Starter .Motor Make/Model Starter Motor Rated Vottage Starter Motor Battery Capacity Inrusti Current Kokusan Oerto Negative 20A Denso 12VDC 580 Ah 800A ! Cranking Current 500 A POWER Industrial Generator Lubrication ••Lubrication •Systertf-'v"- '-•••.-':.•••••• •• ; • V:' ' •''= '' SO Hz ••'•• r?'-\ • • Type System Capacity Less Filter System Capacity-Wffli Filter Otf fitter Oil Pressure At Rated Speed (Mm ) Gear Driven 2 0 gallons (7 6 liters) 2 1 gators (7 9 liters) Ful flow with replaceable spin-on paper element type filter 35 psi (241 3 KPa) Oil Temperature Normal Range Maximum Range 135 230 f (85 110 Cf 230^(110-0) Cooling Cooling System ' •••'-' ' ." • 60 Hz : Exhaust Manifold Type Radiator Design Ambtent Temperature Paling Dry Standard honzontal discharge I040F(40DC) Coolant Capacity Engine Only Engine and Radiator 0 7 gallons (2 3 liters) TBO Water Pump Design Type Coolant Flow Radiator Cooling Air Sett driven Centrifugal 54 gaPhm (205L/min) 3810 cfm [lOflmVmn) Heal Rejection At Rated Load To Coolant j Standby 13092 BTU/rmn (23 k«) . Fan Diameter Fan Horsepower 150 in (380mm) 08hp(06*W) Maximum Static Pressure Head j 14 5psi (100kPa) Thermostat High Waier Temperature indication Pressure Cap Setting Pre-Alarm 2102°F;99'C) Shutdown 221 *F (105 °C) 14psi(97kPa) Fuel Consumption __ -, Feed pump pressure Feed pump maximum suction head Fuet Consumption * t At full load *—. _ _ At3/4load^ _ """' ' At 1/2 load At 1/4 toad 39psi(27kPa) 19 7 in gph 144 105, 074"" 045 (05m) | If* ]_ 547 ! 399 I " " 2 Si"" | 170 Derating The engine may be operated up to 500 ft. and up to 25°C without derating For - operation at higher attitudes and a/rbterrt temperatures, the power should be derated accordng to 'he following factors 60Hz 3%MCOOf! GENERATOR CONTROLLER » ICS-50™ mcroprocessor-based digital generator controller M 12or24VoltDCcompatibte « Meets all NFPA110 requirements for emergency power systems Levef I installations • Backirt LCD display screen wrth alphanumeric readout • Front panel keypad provides password protected programming • Self diagnostic features continuously verify processing, input/ output and memory circuits • Metering accurate to ±1% within temperature range of 0°C to +50°C • EMI/RFI notse immunity and surge performance per iEEE C6241 • Certrfied to UL508 and CSA 22 2 #14 Industrial Control Equpment Standards Standard Controller Features AC Metering Display • Voltage/Amperage/ Frequency • Generator Phase Voltage / Current • Generator Frequency Engine Information Display • Engine Temperature / Oil Pressure (psi) • Battery Voltage (DC) / Tachometer • Hour meter Timer Countdown Display • Engine Start Delay • Oil Bypass • Overcrank • Cycle Crank • Rest Period • Starter He-engage Delay • Bypass Delay Minor Fault Warning Disofay • Swiicn Not In Auto • Low Fuel Level • Low Oil Pressure Alarm • LOW tngine temperature • High Engine Temperature Alarm • Low Battery Voltage • High Battery Voltage • Weak Battery Condition • Battery Charger Input Fail • Undervoltage • L/nderfrequerrcy « Overfrequency • Overcurrent Major Fsutt Shutdown Display « OvervoKage • Emergency Stop • Loss Of Speed • Overcrank • Overspeed • Low Oil Pressure • High Engine Temperafure • Low Coolant Level • Spare Programmable Digital Fauits Switches And Operating Controls • Run / Off / Auto / Load Test Buttons • Decrement / Increment / Previous (Exit) /Next (Enter) Program Buttons • Emergency Stop Button • Audfcle Alarm Horn - 80 dB(A) at 2 feet • Alarm Horn Silence Button • Lamp Test Button • Fault Reset Function • RJ45 Remote Communications. External Expansion Module Ports Control LED Indicators • Switch Position (Run Off Aulo Load Test) • Common Alarm [Minor Fault) • Common Shutdown (Major Fault) • Generalor Ready (When ,n Auto) • Speed Signal • Emergency Stop Diagnostic LED Indicators • fluff Oufptrf Energized • Crank Output Energized m Remote Start Signal Inflated • Common Fail Output Energized • Watchdog CPU Running » Programmable Output Contains POWER Industrial Generator Generator Set Options Alternator 3 Generator Stnp Heater u Permanent Magnet Generator (PMG) Control Pane* 3 Remote Monitoring and Generator Network Communications bnk 3 Voltage Adjusting Rheostat Cooling System Coolant Healer Low Coolant Shutdown Safety 3 Radiator Duct Range Engine Electronic Governor >3 Eno/ieCrankcase Ventilation Rlter Enclosed Unit fc OutdoorWeaiher-protective Housing 3 Outdoor Sound-Attenuated Housing Crrtical Grade Exhaust Silencer Exhaust Mounting Package u Rain Cap Open Unit 3 Cntocal Exhaust Silencer 3 Exhaust Mounting Package Electrical System 3b Battery 3 Environmental Plastic Battery Box *a Battery Charger, Equalize/RoatType i 3 5 Amperes u Battery Charger w/AJarms, Equalize/Roat Type, 10 Amperes Fuel System 3Sub-baseFuelTank{12-hr/25ga]), Double Wall, UL142 3b Sub-base Fuel Tank (24-hr / SOgal), Double Wall, UL142 Automatic Transfer Switch 3 Amperage 3 No Potes 3 Type Enclosure 3 Options Weights and Dimensions '' •• fj S,, ', ' ,' r * / " Housed Gen Set Weight Dry Weight Wet a 74 0 inches 18796mm 3563 nches 9050mm TBD TBD 5408 nches 13736mm Backfeed to a utility system can cause electrocution and/or property damage Do not connect to any building's electrical system except Ihrough an approved device Your MQ Power dealer ts • Miscellaneous 3 Man Une Circuit Breaker 3120/208 Vbft, 3 Phase 3 Pole 3120/240 Vbtt 3 Phase, Delta, 3 Pole 3139/240 \falt, 3 Phase, 3 Pole 3277/480 \foft, 3 Phase, 3 Pole -3w 120/240 Vblt, 1 Phase, 2 Pole 3 Man Une Circuit Breaker Op&ons 3 Auxiliary Contacts -jDC Shunt Tnp 3 Remote Annunciator Panel j Remote Emergency Stop Kit 3 Vibration Isolators, Spring Type MQ POWER POST OFFICE BOX 6254 CARSON, CA 90749 310-537-3700 • 800-883-2551 FAX 310-632-2656 E-MAIL mqpower©mutoqurp com WEBSITE www mqpower com ^COPYRIGHT 2004, tf ULT1QUP INC Rev 0 (6-0*) O O < a:<<0 >~CD X tn< , .co —03 13O •O y-5 * CDCfL 3c UJ? G3£5 ZQ; 8°O >1S3< :D, m NS £gU. 3513 <oy S.° t/) Ofc I 0 a o ? 2 022 STRANDED COPPERWIRE RUNS WITH CONDUIT^ o^ ar3 o r >c y. ^—^ ^t—^f, ; ~ = i— . <2ct. ujCL 1 r^ > t- , — - - ++ -~ ~~~ Z i— UJ <o oror LJi . t -^f 2 UJUJ O [> • • ' 1 — 1• — rr =: >,t .0-f i3wav3 aoooino ?* «Q«0 N33NW .o-.f .o-,s M^urcM., ucru iriUMI C Ur UIMDIU 1 Y INSUKANUt w/oi/zooe 'RUDUCER (949)857-4500 FAX (949)857-4800 Millennium Risk Management & Insurance Services License # OC13480 S530 Trabuco Road Ir 2, CA 92620 NSUFU- Performance Plus Installations Inc. Motive Energy Telecommunications Group Inc. Motive Energy Construction Inc. 125 E. Commercial Street Anaheim, CA 92801 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW INSURERS AFFORDING COVERAGE INSURERA. Majestic Insurance Company INSURER B INSURER C INSURER D INSURER E AVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES AGGREGATE LIMITS SHOWN MAY HAVE 8EEN REDUCED BY PAID CLAIMS ISRTR 4 TYPE OF INSURANCE GENERAL LIABILITY COMMERCIAL GENERAL LIABILITY _J CLAIMS MADE j ] OCCUR GEN'L AGGREGATE LIMIT APPLIES PER | POLICY | | JECT | | LOG AUTOMOBILE LIABILITY 1 ANY AUTO ALL OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON OWNED AUTOS - *AGE LIABILITY ANY AUTO EXCESS LIABlLrTY __] OCCUR | 1 CLAIMS MADE DEDUCTIBLE RETENTION $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY OTHER POLICY NUMBER C20060337701 POLICY EFFECTIVEDATE (MM/DD/YY) 01/01/2006 POLICY EXPIRATIONDATE [MM/DD/YY] 01/01/2007 UMITS EACH OCCURRENCE FIRE DAMAGE (Any one fire) MED EXP (Any one person) PERSONAL & ADV INJURY GENERAL AGGREGATE PRODUCTS - COMP/OP AGO COMBINED SINGLE LIMIT(Ea accident) BODILY INJURY (Per person) BODILY INJURY (Per accidenl) PROPERTY DAMAGE (Per accident) AUTO ONLY - EA ACCIDENT rtTMFR THAN ^ ACC AUTO ONLY AGQ EACH OCCURRENCE AGGREGATE Y WCSTATU- 6TH-A TORY LIMITS ER EL EACHACCfDENT E L DISEASE - EA EMPLOYEE E L DISEASE - POLICY LIMIT S 5 $ S $ $ $ S $ S $ S S $ $ $ S S 9 1,000.000 s 1,000,000 $ 1,000,000 eSCRIPTlON OF OPERATIONS/LOCATIONS/VEHICLES/EXCLUSIONS ADDED BY ENDORSEMENT/SPECIAL PROVISIONS .ERTIFICATE HOLDER ADDITIONAL INSURED, INSURER LETTER CANCELLATION Proof of Insurance SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING COMPANY WILL ENDEAVOR TO MAIL 30 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO MAIL SUCH NOTICE SHALL IMPOSE NO OBLIGATION OR LIABILITY OF AMTHnrfcyPON THE COMPANY. ITS AGENTS OR REPRESENTATIVES y AUTHORIZED REPRESENTATIVE / U JL M^\^%. J vf. A«*~+*~- .CORD 25-S (7/97) I/ " ' ^CORD CORPORATION 1988 V ^o *j ^ ^ i? ^,^•I> \isH * ss il1Ci«* ^ ^cv ? i*?S >,io >= 4-»X3 6 5 > * $ g"flSTmlz »^olSo°i?l5 -o -xs A HCP >^1 ?c 4^ •V f