HomeMy WebLinkAbout2711 LLAMA CT; ; CB980248; PermitB U I L D I N G P E B M I T Permit No: CB980248 05/14/98 13:09 Project No: A9800320 Page 1 of 1 Development No: Job Address: 2711 LLAMA CT Suite: Permit Type: RESIDENTAL ADD/ALT Parcel No: 215-420---07---00 Lot#: Valuation: 29,328 Construction Type: VN Occupancy Group: Reference#: Status: ISSUED Description: 312 SF ADDITION-1ST STORY- Applied: 01/28/98 BEDROOM & BATH Apr/Issue: 02/26/98 Entered By: RMA Appl/Ownr : CROWN BUILDERS 2014 ESTELLA EL CAJON CA 92120 619 258-588805/14/90 0001 01. 02 700 C-PRMT *** Fees Required *** Fs..Collected & Credits Fees: 585 . 0.0 _ Adjustments: 'Tchal C1.?i:its: .00 Total Fees: 5.00Lj Totfvme \ 578.00 / a F, 7.00 Fee description / Units 'F r:t Ext fee Data / FL" '"-' \ Building Permit / / :. \ \ 285.00 Plan Check / y \ 185.00 Strong Motion Fee . / ç •fl 3.00 * BUILDING TOTAL 473.00 Enter "Y" for Plumb ( ,' /) ' 20.00 Y Each Plumbing Fixture (:)r Fr - f ' '7•• / 28.00 Each Building Sewer ~ater \ , piJkJ'/ i5.V(' / 15.00 Each Install/Repair rne7/>' Ic.1 / 7.00 7.00 Enter 'Y for Electric issue Lee, > 1 10.00 1 Enter "1' for Remodel\\ RTE ç- / 10.00 1 19552 Enter 'Y' for Mechanica'j (F!sS_ uF'- -', \ ( / 15.00 1 Each Exhaust Fan \ - 1'' '<50 6.50 FINAL APPROVAL INSPR UAW DATE CLEARAPE CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 FOR OFFICE USE ONLY PERMIT APPLICATION PLAN CHçKNO. CITY OF CARLSBAD BUILDING DEPARTMENT EST. VAL. 2075 Las Palmas Dr., Carlsbad CA 92009 Plan Ck. Deposit I V.1 (760) 438-1161 02 Date I' 1 ROJEC INFORMATION - iitl UL,A"4r CT'. Address (include Bldg/Suite #) Business Name (at this address) '-a-r ,'2.f .LtP(p473(.7 Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units Assessor's Parcel # Existing Use Proposed Use IE €' t -'& - n- cPOi1.) Description of Wolk SQ. FT. #oVStories # of Bedrooms # of Bathrooms CONTACT PERSON if different from applicant) 7e' )4bM7-Jo 4/ 6L72 sc c.4.'f2(fr Name Address City State/Zip Telephone # Fax # APPLICANT 0 Contractor ,gent for Contractor 0 Owner 0 Agent for Owner 4--7 IS1 6YA !i;~n. Q0 Zl?. Name Address City State/Zip Telephone # PROPERTY OWNER OkJrP th4-t46y&/ -17/I 41-i, or- 4&SQ #- ?Z2? 76. ç&' Name Address City State/Zip Telephone # CONTRACTOR - COMPANY NAME - - (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001). w'.J CA 12/2., f/4 • 2r. 'RAO Name State License # Address License Class I - - . - - City I. State/Zip Telephone # City Business License # Designer Name Address City State/Zip Telephone State License # 6 R 'NSATION Workers Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 0 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: lacnpany 5T7TE 2A4 IFIourcrNe, 677965q '7 E onDYtOO (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS) C] CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawf njlj all jdbject an employer to criminal penalties and civil fines up to one hundred thousand4oIlars ($100,000), in addition to the cost of compensatio , aI prgGded for in Section 3706 of the Labor code, interest and attorney's fees. -SIGN-A-TURE CZA7E_________________ 7 OWNER BUILDER DECLARATION I' I hereby affirm that I am exempt from the Contractor's Li e Law for the following reason: o I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section Business and Professions Code for this reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES DNO I (have / have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name / address I phone number / contractors license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address I phone number I Contractors license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): PROPERTY OWNER SIGNATURE DATE COMPLETE THIS SECTION FOR NONRESIDENT/AL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. S.' CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued Sec. 3(7 Civil Co1e LENDER'S NAME LENDER'S ADDRESS 9 APPLICANT CERT)FICATION I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit' of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended or abandont.any-.time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). WHITE: File YELLOW: Applicant PINK: Finance CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB980248 FOR 06/25/98 DESCRIPTION: 312 SF ADDITION-1ST STORY- BEDROOM & BATH TYPE: RAD JOB ADDRESS: 2711 LLAMA CT APPLICANT: CROWN BUILDERS PHONE: CONTRACTOR: PHONE: OWNER: PHONE: INSPECTOR AREA PS PLANCK# CB980248 CCC GRP CONSTR. TYPE VN STE: LOT: 619 258-5888 REMARKS: C/HUGH/619/206-2741 SPECIAL INSTRUCT: TOTAL TIME: CD LVL DESCRIPTION 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical INSPECTOR ACT COMMENTS ('4rS 1, R44 S t c24 ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP COMMENTS 061598 Sewer/Water Service AP PS 052098 Rough/Topout AP PS NEW ELEC NOT ON CIRCUIT CARD 051398 Sewer/Water Service NS PS HOLD ON INSP 051298 Interior Lath/Drywall CO PS INSTALLING NEW PLUMB-NO APPRO 051298 Exterior Lath/Drywall CO PS 051298 Underground/Conduit-Wiring CO PS 050598 Insulation AP PS 050598 Rough Combo AP PS 043098 Frame/Steel/Bolting/Welding CO PS LOOSE ANCHOR BOLTS OK TO INSU 043098 Rough/Topout AP PS 043098 Rough Electric AP PS 043098 Rough/Ducts/Dampers AP PS 042298 Rough Combo CO PS NEED ROOF LOADED 042098 Shear Panels/HD's AP PS 040798 Roof/Reroof AP PS 032398 Ftg/Foundation/Piers AP NF 032398 Underground/Under Floor AP NF 030998 Ftg/Foundation/Piers AP PS EsGil Corporation Professional Plan Review Engineers DATE: 2/25/98 JURISDICTION: Carlsbad PLAN CHECK NO.: 98-248 PROJECT ADDRESS: 2711 Llama Ct. PROJECT NAME: Haugen Room Addition SET: III D APPLLSANT 'LJ tTlVI EWER J FILE I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. El The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: LI Esgil Corporation staff did not advise the applicant that the plan check has been completed. I Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Terry Montello Date contacted: 2/25/98 (by: CM) Mail Telephone Fax In Person LI REMARKS: By: Chuck Mendenhall Esgil Corporation DGA E] CM E:JEJ 1-1 PC walk in Telephone #: In Person Fax #: Enclosures: trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (619) 560-1468 • Fax (619) 560-1576 EsGiI Corporation Professiona[P1Tan Review Engineers DATE: 2/20/98 JURISDICTION: Carlsbad PLAN CHECK NO.: 98-248 PROJECT ADDRESS: 2711 Llama Ct. SET: II U APPLICANT JURI N REVIEWER U FILE PROJECT NAME: Haugen Room Addition The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. El The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Terry Montello 4715 60th St. San Diego, Ca. 92115 I Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted (by: ) Fax #: Mail Telephone Fax In Person LI REMARKS: By: Mike Puckett Enclosures: Esgil Corporation EGA LICM EEJ U PC 2/12/98 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (619) 560-1468 • Fax (619)560-1576 GENERAL PLAN CORRECTION LIST IJURISDICTION: Carlsbad PLAN CHECK NO.: 98-248 PROJECT ADDRESS: 2711 Llama Ct. DATE PLAN RECEIVED BY DATE REVIEW COMPLETED: ESGIL CORPORATION: 2/12/98 2/20/98 REVIEWED BY: Mike Puckett FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. Please make all corrections on the original tracings and submit two new sets of prints to: ESGIL CORPORATION. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? E3 Yes The following corrections are items not completely addressed from the previous plan review. Item #7 Please show the counterfiash at the wall/roof intersection or provide the roof covering manufacturer listing for the intersection detail. Item # 8 Please show that all windows within a 2'-0" radius arc from any doorjamb to be tempered. See window #4. Item # lOSpecify on the plans the following information for the roof materials, per Section 106.3.3: Manufacturer's name. Product name/number ICBO approval number, or equal. Item #20 The CFI R as completed is incorrect in showing the amount of glazing in the new room addition. The package requirements show only 20% new glazing plus any removed glazing is allowed. The window areas of the room addition exceed the allowed. Reduce the glazing to within the limits prescribed or provide an energy analysis of the existing house and the new addition. On the CF1 R please show only the areas of the windows in the addition if the addition prescriptive package is used. Please rework the CFI R to show compliance with state Title 24 energy requirements. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Mike Puckett at Esgil Corporation. Thank you. EsGil Corporation fProfessionaJPIan Review Engineers DATE: 2/6/98 JURISDICTION: Carlsbad PLAN CHECK NO.: 98-0248 PROJECT ADDRESS: 2711 LLama Ct. PROJECT NAME: Haugen Room Addition SET: I o APPLICANT .'JURIS. El PLAN REVIEWER U FILE LII The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. LI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Terry Montello 4715 60th St. San Diego, Ca. 92115 Esgil Corporation staff did not advise the applicant, except by mail, that the plan check has been completed. Li Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person LI REMARKS: By: Mike Puckett Enclosures: Esgil Corporation Lj GA lJ CM EJ EJ 0 PC 1/29/98 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (619) 560-1468 • Fax (619) 560-1576 Carlsbad 98-0248 2/6/98 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 98-0248 JURISDICTION: Carlsbad PROJECT ADDRESS: 2711 LLama Ct. FLOOR AREA: 312sf Addition STORIES: 1 HEIGHT: REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 1/28/98 DATE INITIAL PLAN REVIEW COMPLETED: 2/6/98 DATE PLANS RECEIVED BY ESGIL CORPORATION: 1/29/98 PLAN REVIEWER: Mike Puckett FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1994 UBC (effective 12/28/95), 1994 UPC (effective 12/28/95), 1994 UMC (effective 2/23/96) and 1993 NEC (effective 12/28/95). The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section. etc. Be sure to enclose the marked up list when you submit the revised plans. LIST NO. I GENERAL SINGLE FAMILY DWELLINGS AND DUPLEXES WITHOUT SUPPLEMENTS (1994 UB C ) r 3 f o r w . d o t Carlsbad 98-0248 2/6/98 1. Please make all corrections on the original tracings, as requested in tI,e correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (619) 438-1161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619) 560- 1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and the 1994 UBC, UMC and UPC and the 1993 NEC. Please specify the code edition on the title sheet. 3. Building set backs are measured perpendicular to the property lines. Please dimension the site plan to accurately show the set back distances that reflect the closest distance to the property line from the room addition. 4. At the new bedroom addition show locations of permanently wired smoke detectors with battery backup: Inside each bedroom. Centrally located in corridor or area giving access to sleeping rooms. Add a smoke detector a dining room side of entrance door to bedroom. 5. Please note/show on the plans that smoke detectors shall be installed in all existing bedrooms and hallways leading to the bedrooms. 6. Dimension on the plans 30" clear width for water closet compartments and 24" clearance in front of water closet. Section 2904. 7. Please provide a detail of the new roof and existing wall intersection showing the flashing and counterflashing per Chapter 15 UBC or the roofing tile manufacturers listing requirements. Carlsbad 98-0248 2/6/98 8. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 (see exceptions): Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors. Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. Please show that window in shower is tempered or more than 60" above the drain. ROOFING Specify roof slope. Specify on the plans the following information for the roof materials, per Section 106.3.3: Manufacturer's name. Product name/number. ICBO approval number, or equal. Note on plans that surface water will drain away from building and show drainage pattern and key elevations. Section 1804.7. Show location of attic access with a minimum size of 22"x30", unless the maximum vertical headroom height in the attic is less than 30". Access must be provided to each separated attic area, shall be located in a hallway or other readily accessible location and 30" headroom clearance is required above the opening. Section 1505.1. FRAMING The proposed 2x8 ceiling joists are over spanned for the spacing of 24" o.c. as the maximum span is 17-3" per UBC. Show ceiling joists of increased size or spacing to meet minimum code spans. Please show all header sizes. MECHANICAL (UNIFORM MECHANICAL CODE) Every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 70 degrees F at 3 feet above the floor in all habitable rooms. Show basis for compliance. UBC, Sec. 310.11. Show extend duct etc. Show the size, location and type of all heating and cooling appliances or systems. Carlsbad 98-0248 2/6/98 ELECTRICAL (NATIONAL ELECTRICAL CODE) Show electrical receptacles along the wall of the new bedroom so as any wall space more that 2'-0" is served and a receptacle located so as all wall space within 6-0" of the outlet is served. PLUMBING (UNIFORM PLUMBING CODE) Provide a note on the plans: In showers and tub-shower combinations, control valves must be pressure balanced or thermostatic mixing valves. UPC Section 410.7 Show shower stall can accommodate a 30" circle and has a minimum floor area of 1,024 sq. in. UPC Section 410.4; ENERGY CONSERVATION The regulations require a properly completed and properly signed Form CF-IR to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. All energy items shown on the plans must be in agreement with the information shown on the properly completed Form CF-IR. Specify on the building plans all of the mandatory energy conservation requirements as listed on the enclosure titled, "Mandatory Measures Checklist". Show the make, model, type and efficiency of the space heating (or cooling) system. For room additions, show compliance with the energy standards. See attached prescriptive energy package. As an alternative a point system computer generated package can be provided. Provide fluorescent general lighting (40 lumens per watt minimum) in kitchen(s) and bathrooms. Provide a note on the plans stating "All new glazing (fenestrations) will be installed with a certifying label attached, showing the U-value." Carlsbad 98-0248 2/6/98 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes L3 No U The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Mike Puckett at Esgil Corporation. Thank you. ENERGY REQUIREMENTS FOR RESIDENTIAL ROOM ADDITIONS - CLIMATE ZONE 7 Floor Area of Room Addition COMPONENT <100 ft2 INSULATION Ceiling R-19 Wall R-13 Floor R-13 GLAZING (FENESTRATION) U-Valuer 0.75 % of added floor area <50 sq. ft. SHADING n/a THERMAL MASS n/a SPACE HEATING Note 45 (no electric allowed) If Gas, efficiency= If Heat Pump: Split System, efficiency= Single Package System, eff.= SPACE COOLING Note If Split System, eff.= If Single Package, eff.= 100-499 ft2 R-30 R-13 R-19 0.75 200-. + Removed 66 Req.4 78%AFUE5 6.8HSPF5 6 . 6HSPF5 10. OSEER5 9.7 SEER' 0 500-999 ft2 >1000 ft2 R-30 R-30 R-13 R-13 R-19 R-19 0.75 0.75 20 + Removed 20% .66 66 Req.4 Req.4 78%AFUE5 78%AFUE' 6.8HSPF5 6.8HSPF5 6.GHSPF5 6 . 6HSPF5 10. OSEER5 10. OSEER5 9 . 7SEER5 9 . 7SEER5 Note' Note' WATER HEATING Note 6 Note6 Please note that some metal-frame windows may not satisfy the U-value requirement of 0.75. For additions and alterations only, dual glazed "greenhouse" windows and. skylights may be assumed to meet this requirement. 20% of added floor area plus the area of any glazing removed because of the addition. A coefficient of 0.66 will be assumed to be provided when dual glazing is used. If the addition will be on top of existing construction, and: (a)If the addition has conditioned area below all portions, then no thermal mass i required. (b) If the addition will be over non-conditioned area (partially or wholly) in a buildinc mostly of raised-floor construction (after the addition), then thermal mass is require' in the addition (equal to 59t of the area of the addition that is over non-conditione( space) . This may be provided by showing a 2" concrete slab at hearths, countertops etc. (c)If the addition will be over non-conditioned area in a building mostly of slab-on grade construction (after the addition), then no thermal mass is required. If the addition will be at the ground floor, and: (a) If the addition will be in a building mostly of raised-floor construction (after th addition), then thermal mass is required in the addition (equal to 5% of the adde conditioned footprint area). This may be provided by showing a 2" concrete slab a hearths, countertops, etc. (b)If the addition will be in a building mostly of slab-on-grade construction (afte the addition) , then thermal mass is required in the addition (equal to 20% of the adde conditioned slab-on-grade floor area) . This may be provided by covering a portion c the slab-on-grade with tile, wood, etc. If the existing system will be utilized (if no additional systems are needed to prOvi USC heating requirements), there are no special requirents, other than mandato insulation for any extended ducts, etc. If the total number of water heaters increases in the residence, then calculations mu. be submitted to show that the entire existing-plus-addition system meets the wat heating energy budget. Carlsbad 98-0248 2/6/98 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 98-0248 PREPARED BY: Mike Puckett DATE: 2/6/98 BUILDING ADDRESS: 2711 LLama Ct. BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION: VN BUILDING PORTION BUILDING AREA (ft. 2) VALUATION MULTIPLIER VALUE ($) Room Addition 312 94.00 29,328.00 Air Conditioning Fire Sprinklers TOTAL VALUE 29,328.00 1991 UBC Building Permit Fee LI Bldg. Permit Fee by ordinance: $ 284.50 1991 UBC Plan Check Fee fl Plan Check Fee by ordinance: $ 184.92 Type of Review: LI Complete Review Structural Only LI Hourly LI Repetitive Fee Applicable LI Other: Esgil Plan Review Fee: $ 147.94 Comments: Sheet I of I macvalue.doc 5196 City of Carlsbad BUILDING PLANCHECK CHECKLIST DATE: - 4 PLANCHECK NO.: CB BUILDING ADDRESS: 2.711 LLA-iI PROJECT DESCRIPTION: tz-.) I72 '—u4 ASSESSOR'S PARCEL NUMBER: J15 -42_' EST. VALUE:' ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. A Right-of-Way permit is required prior to construction of the following improvements: DENIAL Please see the attached report of deficiencies marked with C5. Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: jf Date: By: Date: By: Date: FOR OFFICIAL USE ONLY B'7' a INRINGAUT IZATIONTO ISSUE BUILDING PERM! Date: 70((04_,,P ATTACHMENTS Dedication Application Dedication Checklist Improvement Application Improvement Checklist Future Improvement Agreement Grading Permit Application Grading Submittal Checklist Right-of-Way Permit Application ENGINEERING DEPT. CONTACT PERSON Name: David Rick City of Carlsbad Address: 2075 Las Palmas Dr.. Carlsbad. CA 92009 Phone: (619)438-1161, ext. 4324 CFD INFORMATION Parcel Map No: Lots: Recordation: Right-of-Way Permit Submittal Checklist Carlsbad Tract: and Information Sheet Sewer Fee Information Sheet A-4 ASPALMAS\SYS\LISRARy\ENGWORD\DOCS\CHKLS'flTh,jinp Plantheck Cklst POOOl Fo.m DR.Uoc Re. 9/3I97 2075 Las Palmas Dr. • Carlsbad, CA 92009!1576• (619) 438-1161 • FAX (619) 438-0894 BUILDING PLANCHECK CHECKLIST SITE PLAN 1 ST/ 2ND/ 3RDJ I 1 1. Provide a fully dimensioned site plan drawn to scale. Show: North Arrow '. Property Lines '-. Existing & Proposed Structures. '. Easements z,-C. Existing Street Improvements 'F. Right-of-Way Width & Adjacent Streets '-G. Driveway widths 4(Q 2. Show on site plan: ( Drainage Patterns 7R.Ak14 Pt 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. ,12. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." L'B. Existing & Proposed Slopes and Topography ' 3. Include on title sheet: Site address '. Assessor's Parcel Number (C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, exitinjewer permits showing square foPtag?p ffr A.,ises (m'nvfa'ètyring â?house, office, etc.) previously apprôve EXISTING PERMIT NUMBER DESCRIPTION DISCRETIONARY APPROVAL COMPLIANCE 4a. Project does not comply with the following Engineering Conditions of approval for I Project No.___________________________________________________________ LI LI 4b. All conditions are in compliance. Date: Panthecj, Cklst BP000I Fomi OR.doc Rev. 9/3/97 BUILDING PLANCHECK CHECKLIST DEDICATION REQUIREMENTS T/ ND/ RD/ 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $_, pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 1/2' x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS All needed public improvements upon and adjacent to the building site must be / f constructed at time of building construction whenever the value of the construction exceeds $ , pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on .the checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: Date: Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $_________________ so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. - - Future public improvements required as follows: \ASPALMAS\SYS\L!BRARV\ENG\WORO\DOCSCHKLSflBuiifl9 Plancheck CkISt BP000I Fon,, DR.doc Rev. 9/3/97 BUILDING PLANCHECK CHECKLIST stj 2ndl 3rdl Enclosed please find your Future Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Future Improvement Agreement completed by: Date: No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). Write "No Grading" on plot plan if none is required. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) No Grading Permit required. 11 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tieing into public storm drain, sewer and water utilities. Right-of-Way permit required for: WJ.ASPALMAS\SYS\tjBRARYENGWORD\DOcS\CHKLSr,8ujId ing Planclieck Mist BP0001 Form ORdoc Rev. 913197 BUILDING PLANCHECK CHECKLIST St.! 2' 3rd.( A SEWER PERMIT is required concurrent with the building permit issuance. The fee is noted in the fees section on the following page. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 153, for assistance. Industrial Waste permit accepted by: Date: NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface poflutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. LI Ui Ui Q Required fees are attached U No fees required Additional Comments: Plancheck Chist BP000I Fonn DR.doc Rev. 9/3/97 9. PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST i r Plan Li g Address Phone (619) 438-1161, extension ., Planner ____ _________ APN: - 01 Type of Project & Use: Net Prqject Density: DU/AC Zoning: Rd General Plan:121-41 Facilities Management Zone: CFD (in/out) #Date of participation: Remaining net dev acres:______ Circle On (For non-residential development: Type of land used created by thispermit:_____________________________________________________ Legend: Z Item Complete Item Incomplete - Needs your action Environmental Review Required: YES NO TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES NO TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of- Approval: Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES NO____ CA Coastal Commission Authority? )E____ NO____ If California Coastal Commission Author!j 'Contact them at - 3111 Camino Del Rio North, Suite 200, San Diego CA 92108-1725; (,31521-8O36 Determine status (Coastal Py'fit Required or Exempt): Coastal Permit Determinfrti'on Form already completed? YES NO____ If NO, complete Coastal P,thit Determination Form now. Coastal Permit Detpi"mination Log #: Follow-Up Ai'ons: Stamp-juiIding Plans as "Exempt" or "Coastal Permit Required' (at minimum FIoo,'lans). Con'Splete Coastal Permit Determination "Log as needed. / OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER Inclusionary Housing Fee required: YES NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES NO (Enter CB #; UACT; NEXT12; Construct housing Y/N; Enter Fee Amount (See fee schedule for a m o u n t ) ; R e t u r n ) Site Plan: Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines. Provide legal description of property and assessor's parcel number. Zoning: 17 fl 1. Setbacks: Front: Interior Side: Street Side: Rear: Required Shown Required , ( Shown / Required Shown Required Ic' / Shown Accessory structure setbacks: Front: Required Shown Interior Side: Requi Shown :Rear: treet Side: equired Shown Required Shown tr re separation: Required Shown Lot Coverage: Required ¶10 Shown Height: Required 30 Shown LI 5. Parking: Spaces Required Shown Guest Spaces Required - Shown E fl fl Additional Comments_______________________________________________________