Loading...
HomeMy WebLinkAbout2714 Arland Rd; ; CBR2017-0306; PermitPrint Date: 10/18/2017 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: II Dwelling Units: Bedrooms: Project Title: 2714 Arland Rd BLDG-Residential 1561303300 $152,000.44 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit www.carlsbadca.gov Work Class: Deck Lot#: Reference II: Construction Type: Bathrooms: Orig. Plan Check II: Plan Check II: Description: GAHR: 1,147 SF POOL HOUSE/PATIO STRUCTURE (CALIFORNIA ROOM) Applicant: Owner: CAROLINE F DOOLEY -ARCHITECT CAROLINE DOOLEY COOWNER GAHR MATIHEW S&KELLY JG 2710 Arland Rd 760-815-8748 BUILDING PERMIT FEE $2000+ BUILDING PLAN CHECK FEE (BLDG) CARLSBAD, CA 92008 760-492-7999 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL MANUAL BUILDING PERMIT FEE MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL SB1473 BUILDING STANDARDS FEE STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1-MEDIUM Total Fees: $1,997.15 Total Payments To Date: $1,997.15 Status: Applied: Issued: Fina led: Inspector: Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Permit No: CBR2017-0306 Closed -Finaled 02/14/2017 04/19/2017 PB urn $0.00 $814.15 $161.19 $66.00 $368.05 $92.00 $182.00 $7.00 $19.76 $232.00 $55.00 ,. . ' THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0PLANNING D ENGINEERING C_cityof Carlsbad Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov www.carlsbadca.gov ~·BUILDING O FIRE 0HEALTH D HAZMAT/APCD Plan Check No. Est. Value Plan Ck. Deposit SW PPP JOB ADDRESS :;i_ 1 I SUITEt/SPACEI/UNITf -130 -ob CT/PROJECT# LOT# PHASE# #OF UNITS # BEDROO # BATHROOMS ITNANT BUSINESS NAME DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) E;Ul L.-1) N8W P()fJL-~tuJciVRE. t15e, I FOOL TD 12tMAi;..! . POOL, ~twGtVRe - EXISTING USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YES~ NcQ APPLICANT NAME PROPERTY OWNER MArT A-"1D ADDRESS I .Pl 4 CITY~';,, STATE Ck- FAX , CoM STATE LIC. # NSTR. TYPE OCC. ROUP V6 FIRE SPRINKLERS YES ONo_g} ZIP c=, 2&t:8 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its Issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law !Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Co<leJ or lhat he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). W()(l(ers' Compensation Declaration: I hereby affirm under penalty of perjiry one of the fo//owfng cfedarations: Q I have and will maintain a certificate of consent to self,lnsure for v.orkers' compensation as provided by Section 3700 of the Labor Code, for the performance of the v.ork for which this permit Is Issued. ~ I have and will maintain wor1ters' compensation, as required~ 3700 of the Labor Code, for the performance of the v.ork for which this permit Is Issued. My v.orkers' compensation insurance carrier and policy number are: Insurance Co. ~ff(l:: Fu~ Policy No. Expiration Date--------- J.l!§, section need not be completed It the permtt Is for one hundred dollars ($100) or less. LJ Certificate of Exemption: I certify tin the perfo of the v.ork for which this permit Is issued, I shall not employ any person In any manner so as to become subject to the Workers' Compensation Laws of Califomia. WARNING: Failure to s re orkel'$' co pen a coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand do\lal'$ (&100,000), In as pro id f 06 of the Labor code, Interest and attorney's fees. I hereby affirm that I am exempt from Contractor's License D D D I, as owner of the property or my employees wtth wages as their sole compensation, win do the v,o,1( and the structure is not Intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such v.ork himse~ or through his own employees, provided that such improvements aie not intended or offered for sale. If, however, the building or improvement Is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or Improve for the purpose of sale). I, as owner of the property, am exdusively conlracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contracto(s License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvemenl O ves 0 No 2. I (have I have not) signed an application for a building permit for the proposed v.ork. 3. I have cootracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number): 5. I will provide some of the v.ork, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of v.ork): _N$ PROPERTY OWNER SIGNATURE 0 AGENT DATE Is the applicant or future building occupant required lo submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Acri CJ Yes o No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D Yes CJ No Is the facility to be constructed within 1,000 feel of the outer boundary of a school site? CJ Yes CJ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I certify that I have read the application and state that the above Information Is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the Cityof Canslw kl enter upon the above menooned ~ tir nspecoon J)JrJX)SeS. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARl..$B4.D AGA.INST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAIDCfTY IN CONSEOJENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA pennit is requred tir excavations CNer 5'0' and dendti:Jn or construction of structures CNer 3 sbies in height EXPIRATION: Ewrypennn issued by the ·ng Offcial u • of !his Cooeshan expre by linilation cm becorre nul cm voo if the wiklingorv.oo< aulhorized by such penm is notoonmenced v.ilhin 100days from the date of such permij or i · ing orv.oo< u s ij is suspended or abandoned at any time afterthev.oo< is oommenced tira ~riod of 1 days (Secti:Jn 100.4.4 Unibrm 9Jilding Cooe). ,8S APPLICANT'S SIGNATURE DATE • STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. C f r· T ! F I C r, T [ 0 F 0 C C U f' i\ r. C Y l C o rn rn L' ; c J .1 I I' r OJ C C t S 0 n I, I Fax (760) 602-8560, Email building@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. CO#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE I FAX EMAIL OCCUPANT'S BUS. UC. No. DELNERY OPTIONS CJ PICK UP: o CONTACT (Listed above) o OCCUPANT (Listed above) o CONTRACTOR (On Pg. 1) o ASSOCIATED CB# CJ MAIL TO: o CONTACT (Listed above) D OCCUPANT (Listed above) o CONTRACTOR (On Pg. 1) o NO CHANGE IN USE / NO CONSTRUCTION CJ MAIL/ FAX TO OTHER: o CHANGE OF USE / NO CONSTRUCTION AS APPLICANT'S SIGNATURE DATE Permit Type BLDG-Residential Application Dato: 02/14/2017 Owner: COOWNER GAHR MATIHEW S&KELLY JG Work Class: Deck Issue Date 04/19/2017 Subdivision: WILSONIA TRACT Status: Closed -Finaled Expiration Dato: 02/06/2018 Address: 2714 A rland Rd Carlsbad, CA 92008-1501 IVR Number: 1953 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete BLDG-23 028895-2017 Cancelled Paul York Reinspection Complete Gas/T esURepairs Checklist ltPrn COMMENTS Passed BLDG-Building Deficiency No 08/10/2017 08/10/2017 BLDG-31 031236-2017 Passed Michael Collins Complete Underground/Condu it-Wiring Checklist Item COMMENTS Passed BLDG-Building Deficiency Conduit only, existing garage to pool house. Yes 09/28/2017 09/28/2017 BLDG-Final 036189-2017 Failed Paul Burnette Relnspectlon Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final No 10/18/2017 10/18/2017 BLDG-Final 037879-2017 Passed Paul Burnette Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes October 18, 2017 Page 2 of 2 Permit Typo: BLDG-Residential Application Date: 02/14/2017 Owner: COOWNER GAHR MATIHEW S&KELLY JG Work Class: Deck Issue Date: 04/19/2017 Subdivision: WILSONIA TRACT Status: C losed -Finaled Expiration Date: 02/06/2018 Address: 2714 Arland Rd IVR Number: 1953 Carlsbad, CA 92008-1501 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete --- 05/05/2017 05/05/2017 BLDG-11 022412-2017 Passed Jonathan West Complete Foundation/Ftg/Pier s (Rebar) Checklist Item COMMENTS Passed BLDG-Bu1ld1ng Deficiency Steel column footings Yes 06/02/2017 06102/2017 BLDG-11 025066-2017 Cancelled Jonathan West Reinspection Complete Foundation/Ftg/Pier s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency No 06/05/2017 06/05/2017 BLDG-11 025225-2017 Passed Jonathan West Complete Foundation/Fig/Pier s (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 06130/2017 06/30/2017 BLDG-13 Shear 027590-2017 Passed Jonathan West Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-15 027591-2017 Passed Jonathan West Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 07/07/2017 07/07/2017 BLDG-84 Rough 028063-2017 Passed Jonathan West Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 07/17/2017 07/17/2017 BLDG-18 Exterior 028894-2017 Passed Paul York Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No October 18, 2017 Page 1 of 2 RA CH COASTA ENGINEERING Si ng l e Sou rc e Deve l op ment Consu ltant April 11 ,2017 RE: PAD CERTIFICATION -Gahr Pool Structure 2714 Arland Road, Carlsbad, CA 92008 A.P.N. 156-130-33 RECEIVED MAY 05 2017 CITY OF CARLSBAD BUILDING DIVISION Pursuant to a field survey by this firm, conducted April 6, 2017, to measure the Graded Pad Elevation & Top of Pool Shotcrete, relative to the Existing Concrete Patio, our findings are as follows: • Existing Concrete Patio = 159.9' (Bench Mark) • Average Gr.aded Pad Elevation= 157.4' • Top of Pool Shotcrete = 157.4' Should there be any questions or comments, please feel free to contact our office. Sincerely, RANCHO COAST AL ENGINEERING & SURVEYING, INC. t.i · II -.1..0 r,· 42 Date Planning Civil Survey Structural Rancho Coastal Engineering and Surveying, Inc. 310 S. Twin Oaks Valley Rd., #107-297, San Marcos, CA 92078 Phone (760) 510-3152, Fax: (760) 510-3153 @ B&B Engineering, Inc. CML, GEOTECHNICAL, & QUALITY ENGINEERING FOUNDATION DESIGN• LAND SURVEYING• SOIL TESTING MR. & MRS. MA TT GAHR 2710 Arland Road Carlsbad, CA. 92008 CLIENT: GAHR PROJECT: GAH 317-FTG PLAN DA TE: 6 MARCH 2017 Subject: Geotechnical Engineering Foundation Plan Certification for the Proposed Pool Structure Construction located at 2710 Arland Road, Carlsbad, CA. (APN: 156-130-33) Reference (a): Site Specific Soil Investigation Report by B & B Engineering, Inc., dated 23 March 2013. Gentlemen: Pursuant to the City of Carlsbad requirements, this letter will serve as confirmation that the Pool Structure foundation plans and specifications have been reviewed for the subject project. We have determined that the recommendations in Reference (a) dated 23 March 2013, have been properly incorporated into the construction documents. Sincerely, /IV Stephen B. Peter RCE 38623 Expires 3-31-17 RECEIVE.) MAR 16 2, 1 CITYOFc ,~. BU/LOIN ARL. . ·, Go1v1 '"-.·..,.,-,: 1611-A SO. MELROSE DRIVE #285, VISTA, CA 92081-5471 Ph: (760) 945-3150 Fax: (760) 726-7514 EsGil Corporation In (J>artnersliip witli (}o'tlernment for <.Bui{iin9 Safety DATE: 4/12/2017 JURISDICTION: Carlsbad PLAN CHECK NO.: CBR2017-0306 PROJECT ADDRESS: 2714 Arland Rd. SET: III CJ APPLICANT LJJLJRIS. CJ PLAN REVIEWER CJ FILE ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: Caroline Dooley ~ EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Carolin~ Telephone#: 760 815-8748 Date conta~ (~<f) Email: caroline@carolinedooley.com Mail Telephone Fax In Person D REMARKS: By: Bert Domingo Enclosures: EsGil Corporation D GA D EJ D MB D PC 4/6/2017 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 EsGil Corporation In !Partnersliip witli qovemment for <Bui(aing Safety DATE: 3/27/2017 JURISDICTION: Carlsbad PLAN CHECK NO.: CBR2017-0306 PROJECT ADDRESS: 2714 Arland Rd. SET: II D APPLICANT D JURIS. D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [8J The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [8J The applicant's copy of the check list has been sent to: Caroline Dooley D EsGil Corporation staff did not advise the applicant that the plan check has been completed. [8J EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Caroline Dooley Telephone#: 760 815-8748 yate contacted: 3/if; (by{)c_.y Email: caroline@carolinedooley.com ~ail h:~~~ Fax In Person DREMA~: By: Bert Domingo EsGil Corporation D GA D EJ D MB D PC Enclosures: 3/20/2017 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad CBR201 7-0306 3/27/2017 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). This will be checked on the final. 14. Please specify the location and amperage of the electrical service which is feeding the 100 Amp subpanel at the Pool House, provide building grounding and bonding design, provide feeder design and provide load calculations showing the existing service is adequate for the existing and new loads. If the service needs to be upgraded to more than 200 amps, provide a single line diagram and panel schedule. Please see the following comments for your consideration: a) Please provide overcurrent device size for the pool and garage sub panels. b) Update feeder size for the garage upgrade to 100 Amps. c) Please show location of the new sub panels as well as the existing service on 2714. d) Match E1 sheet notes with single line diagram. Carlsbad CBR2017 -0306 . 3/27/2017 MISCELLANEOUS To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes D No D The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bert Domingo at EsGil Corporation. Thank you. EsGil Corporation In <Partnersliip witli (jovernment for (JJui{aing Safety DATE: 2/23/17 JURISDICTION: Carlsbad PLAN CHECK NO.: CBR2017-0306 PROJECT ADDRESS: 2714 Arland Rd. PROJECT NAME: Gahr Pool Structure SET: I 0 APPLICANT .~URIS. 0 PLAN REVIEWER 0 FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [8J The applicant's copy of the check list has been sent to: Caroline Dooley D EsGil Corporation staff did not advise the applicant that the plan check has been completed. [8J EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Caroline Dooley Telephone#: 760 815-8748 Date contacted21rz.4--(byY'C_} Email: caroline@carolinedooley.com ~ail VTe:lephone Fax In Person D REMAKK~: By: Tamara Fischer EsGil Corporation D GA D EJ D MB D PC Enclosures: 2/16/17 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 . Carlsbad CBR2017-0306 2/23/17 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: CBR2017-0306 JURISDICTION: Carlsbad PROJECT ADDRESS: 2714 Arland Rd. FLOOR AREA: 1147 Sq ft Pool Cabana STORIES: 1 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 2/23/ 17 FOREWORD (PLEASE READ): HEIGHT: 13' approx DATE PLANS RECEIVED BY ESGIL CORPORATION: 2/16/17 PLAN REVIEWER: Tamara Fischer This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2016 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC, 2015 UPC, 2015 UMC and 2014 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBR201 7-0306 2/23/17 1. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Please specify whether there are any changes to the pool barrier as a result of this project. If so, show compliance with section 3109.4.4.3, CBC. 4. Specify on the plans the following information for the skylights, per Section R 106.1.1: ICC approval number, or equal. The ICC approval number specified on sheet A2 is not a currently valid approval. 5. The City of Carlsbad requires a soil report for this project. It does not meet the exception since it exceeds 500 sq ft. Please provide a copy of the project soil report. The report shall include foundation design recommendations based on the engineer's findings and shall comply with Section R401.4. If the report is more than 3 years old or exceeds the limitations in the report, an update letter is required. 6. If the soils engineer recommended that he/she review the foundation excavations, note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: a) The building pad was prepared in accordance with the soils report, b) The utility trenches have been properly backfilled and compacted, and c) The foundation excavations, the soils expansive characteristics and bearing capacity conform to the soils report." CONTINUED Carlsbad CBR201 7-0306 2/23/17 7. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (if required by the soil report). 8. Please reference spread footings at steel columns to the schedule. 9. Please check grade beam dimensions at detail 6/SD3. It appears they are switched. 10. 5/SD2 which shows bent steel beam supported by a post is referenced where the bent steel beam is supported by the Glu-Lam beam. Please provide a detail for this condition. 11. Please update the structural plans to match the architectural plans at grid AA between grids 3 and 4. 12. Show the dryer exhaust duct from the dryer to the exterior. CMC Section 504.4.2. 13. Please provide listing information for the outdoor cooking appliance and vent hood, to verify clearance to combustibles and overhead protection. Additionally, it must be listed for interior use. CMC Section 921.0. 14. Please specify the location and amperage of the electrical service which is feeding the 100 Amp subpanel at the Pool House, provide building grounding and bonding design, provide feeder design and provide load calculations showing the existing service is adequate for the existing and new loads. If the service needs to be upgraded to more than 200 amps, provide a single line diagram and panel schedule. 15. Include on the plans the following specifications for electrical devices: CEC Article 210 & 406 a) Please specify all receptacles to be tamper resistant. b) Current code requires all kitchen and laundry outlets to be Arc-fault protected in addition to GFCI protected. NEC 210.12(A). CONTINUED Carlsbad CBR201 7 -0306 2/23/17 16. Please update lighting notes to comply with the current energy standards. a) All installed luminaires shall be high-efficacy in accordance with ES TABLE 150.0-A. Light sources that are not marked "JA8-2016-E" shall not be installed in enclosed luminaires. ES 150.0(k) b) In laundry rooms, and utility rooms at least one luminaire shall be controlled by a vacancy sensor. c) Dimmers or vacancy sensors shall control all LED style luminaires. Two exceptions: Fixtures installed in hallways or (closets under 70 square feet). d) Recessed can light fixtures shall be IC listed, air-tight labeled, and not be equipped with a standard medium base screw shell lamp holder. ES 150.0(k) e) SFD ouJc:l9.9rJjghting fixtures that are attached to a building are required to be high efficacy, be manually on/off switch controlled, and have both motion sensor and photocell control. See ES 150.0(k) 3 for additional control options. MISCELLANEOUS To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: a) Yes D No D The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Tamara Fischer at EsGil Corporation. Thank you. Carlsbad CBR2017-0306 2/23/17 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: CBR2017-0306 PREPARED BY: Tamara Fischer DATE: 2/23/17 BUILDING ADDRESS: 2714 Arland Rd. BUILDING OCCUPANCY: R3 BUILDING AREA Valuation Reg. VALUE ($) PORTION ( Sq. Ft.) Multiplier Mod. Pool Cabana 1147 132.52 152,000 Air Conditioning Fire Sprinklers TOTAL VALUE 152,000 Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: 0 Complete Review D Structural Only D Repetitive fee --.;, Repeats D Other D Hourly ----IHr@' $455.961 EsGil Fee Comments: Sheet 1 of 1 macvalue.doc +