Loading...
HomeMy WebLinkAbout2714 LOKER AVE W; ; CB131060; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 10-24-2014 Commercial/Industrial Permit Permit No: CB131060 Building Inspection Request Line (760) 602-2725 Job Address: fl AS' 2714 LOKER AV WEST CBAD 1,,,:., Permit Type: Tl Sub Type: INDUST Status: ISSUED Applied: 04/25/2013 Entered By: RMA Parcel No: 2090813200 Lot#: 0 Valuation: $60,000.00 Construction Type: NEW Occupancy Group: Reference# Plan Approved: 10/24/2014 Issued: 10/24/2014 Inspect Area Plan Check #: Project Title: AT&T CELL SITE-REMOVE 8 EXIST! ANTENNAS & INSTALL 12 NEW ANTENNAS, 6 NEW RRU'S & SURGE PROTECTORS, 1 NEW GPS ANTENNA BEHIND STEAL TH SCREENS Applicant: Owner: MARGIE SULLIVAN CB LL LC 302 STATE PL ESCONDIDO CA 92029 760-715-3416 Building Permit Add'I Building Permit Fee Plan Check Add'I Building Permit Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Fire Expedidted Plan Review Total Fees: $862.95 $499.62 $0.00 $349.73 $0.00 $0.00 $12.60 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $1.00 $0.00 6183 PASEO DEL NORTE #280 CARLSBAD CA 92011 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFD Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees HMP Fee Green Bldg Standards Plan Chk TOTAL PERMIT FEES $862.95 Balance Due: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 ?? ?? $862.95 $0.00 Inspector: FINAL APPROtL _, Date: 6 / 'ff 2,i>/t:> Clearance: _____ _ NOTICE: Please take NOTI E that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which ou have reviousl been iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired. THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: ENGINEERING «~ ~ CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov www.carlsbadca.gov SUITE#/SPACE#/UNIT# JOB ADDRESS 2714 Loker Avenue West CT/PROJECT# LOT# PHASE# # OF UNITS # BEDROOMS #BATHROOMS DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) Modification of existing AT&T cell site to include removal of (8) 4'4" antennas and install (12) new 4'7" antennas, 6 new RRU's, 6 new surge suppressors, and 1 new GPS antenna behind new antenna stealth screens. EXISTING USE PROPOSED USE AIR CONDITIONING FIRE SPRINKLERS commercial bldg no change GARAGE (SF) na No[ZI YES0No!ZI YESONo!ZI APPLICANT NAME (Primary Contact) AT&T Mobility, LLC . -l<aret'l Acller-PlanCom, Inc. ADDRESS 7337 Trade Street 302 State Place CITY STATE ZIP CITY STATE ZIP San DieAo CA 92121 Escondido CA 92029 PHONE FAX PHONE 760-715-3416 760-735-4913 760-735-4913 EMAIL EMAIL karen.adler(@,plancominc.com PROPERTY OWNER NAME C.B.L, LLC ADDRESS 5800 Armada Dr. Ste. 200 CITY STATE ZIP Carlsbad CA 9200 PHONE FAX Lucia 760-931-1134 EMAIL ,;t;e/ ARCH/DESIGNER NAME & ADDRESS STATELIC.# IS.LIC.# Black & Veatch 80188 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement tt\at he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declara6ons: !Kl I have and will maintain a certificate of consentto self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit Is issued. []) , have and will maintain workers' compensation, as reouired by Section 3700 of the Labor Code, for the performance of the work for which this permitis issued. My workers' compensation insu nee carrier and policy ' .--r-_.. __ n . ,a number are: Insurance CoS:bH'.e dir,,f61Vf*'•.2>t11 .:7,u.,-~ Policy No. z r l3 f/6 //3-1 Expiration Date 10 I .:;:u))..!5 This section need not be completed ff the permn Is for one hundred dollars ($100) or less. D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as lo become subject to the Workers' Col(lpensalion Laws of California. WARNING: Failure to secure workers' mpensatlon coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damages p~ ~~~bor code, interest and attorney's fees. _2$ CONTRACTOR SIGNATURE /2>-<-"'-.,,,~......-/ ~ AGENT DATE I hereby affirm that I am exempt from Contractor's license Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or Improves thereon, and who does such work himseff or through his own employees, provided that such improvements are not intended or offered for _ , sale. If, however, the building or improvementis sold within one year of completion, the owner-buikler will have the burden of proving that he did not build or Improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section ____ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the pro~osed property Improvement. 0Yes ~No 2. 1S, have not) signed an application for a building permit for the proposed work. ~ti'\ 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): I Vy 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone I type of work): _2$ PROPERTY OWNER SIGNATURE DATE 1/ THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0PLANNING 0ENGINEERING OBUILDING OFIRE OHEALTH 0HAZMAT/APCD {'Cityof Building Permit Application Plan Check No. 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value Carlsbad Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit email: building@carlsbadca.gov www.carlsbadca.gov Date lswPPP JOB ADDRESS SUITE#/SPACE#/UNIT# IAPN --- CT/PROJECT# ILOT# I PHASE# I# OF UNITS I# BEDROOMS # BATHROOMS I TENANT BUSINESS NAME I CONSTR. TYPE I occ. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) EXISTING USE I PROPOSED USE I GARAGE (SF) PATIOS (SF) I DECKS (SF) FIREPLACE I AIR CONDITIONING I FIRE SPRINKLERS YEsO. NoD YES0No0 YEsONoO APPLICANT NAME PROPERTY OWNER Primary Contact ADDRESS ADDRESS CllY STATE ZIP CllY STATE ZIP PHONE (AX PHONE IFAX EMAIL EMAIL DESIGN PROFESSIONAL ~ ,£ONTRACTOR BUS. NAME .I/ / ' I.., ) }1,tt"., J • IA, ADDRESS ADDRESS J . ~t.fl(l( & 1-c:v &1..\Avnr...t '\:),;~ CllY STATE ZIP CllY STATE ' ZIP Muvv ;...Pk cvl ?2."Sl'\ PHONE IFAX PHONE I FAX '€<Se:J-~ 7lf· je;.?lf EMAIL EMAIL ISTATELIC. # STATELIC.# 9 'l/<; II J er: C /t? I CITY~l,/ t1 (Sec, 7031.5 Business ~nd Profes~ions Code: Any City or C(!unty which requires a permit to_c9nstruct, alter, (mpro~e, qemolish or re air any structure, p_rior to its iss~anc{(, a(so ~ires the applicant for such permit to file a signed statement that he Is licensed pursuant to the provIsIons of the Contractors License Law fC~apter 9, commending with Section 7000 of 151v1s1on 3 of the Business and Professions Code) or that he is exemP.t therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500)). Workers' Compensation Declaration: / hereby affirm under penalty of pe,jury one of the following declarations: m I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy numberare:lnsuranceCo. r~~\ ) ... $ t'.'.'t>c....y<!:."'1' PolicyNo. oc.fq ?'2..7$°.S'f" Expiration Date 2// {/? This section need not be completed if the permit is for one hundred dollars ($100) or less. fflcertificate of Exemption: I certify thatin the performance of the work for which this permitis issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of Cattfomia. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in _ j addition to the cost of compensation, damages vide~3706 of the Labor code, interest and attorney's fees. {)\ 1-,-~.....,..,.c_oN.,.T,...RA_c_ro_R_s_1G_N_AT_U....,RE-#f.:::;;..,...,.__-__ ~ ___ ...,.....,_ _ _,... _ _,....,....------....;O;;;;;;..A_G_E_NT..,.,.. __ ...--D,..AT_E......,.:...:::,.:...;---'.....,.~---.,.,.......,..,...---,1 0wm~©;;;©©Oi1,t1' !3,J:fJ '@@Zs~~m~~O®,W '··1 ·. I hereby affirm that I am exempt from Contractor's Ucense Law for the following reason: D D D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale}. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s} licensed pursuant to the Contractor's License Law}. I am exempt under Section _____ .Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0Yes 0No 2. I (have/ have not} signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm} lo provide the proposed construction (include name address/ phone/ contractors' license number}: 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number}: 5. I will provide some of the work, but I have contracted (hired} the following persons to provide the work indicated (include name/ address/ phone/ type of work}: ~ PROPERTY OWNER SIGNATURE OAGENT DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? CJ Yes CJ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? CJ Yes CJ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? CJ Yes CJ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address I certifythatl have read the application and state that the above infonnation is correct and that the infonnation on the plans is accurate. I agree to complywith all City ordinances and State law.; relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or l',l)fk authorized by such permit is not commenced 1-.ithin 180 days from the date of such permit or if the bu' ing or l',l)fk authorized by such permit is suspended or abandoned at any time after the l',l)fk is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code) . ..@S' APPLICANT'S SIGNATURE DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CERTIFICATE Of OCCUPANCY /Commercial Projects only) Fax (760) 602-8560, Email www.building@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. I CO#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE I FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS CJ PICK UP: o CONTACT (Listed above) o OCCUPANT (Listed above) o CONTRACTOR (On Pg. 1) o ASSOCIATED CB# CJ MAIL TO: o CONTACT (Listed above) o OCCUPANT (Listed above) o CONTRACTOR (On Pg. 1) o NO CHANGE IN USE/ NO CONSTRUCTION CJ MAIL/ FAX TO OTHER: o CHANGE Of USE/ NO CONSTRUCTION ,g APPLICANT'S SIGNATURE DATE Inspection List Permit#: CB131060 Type: Tl Date Inspection Item ____ _ 05/07/2015 89 Final Combo 05/07/2015 89 Final Combo 05/06/2015 89 Final Combo 05/01/2015 89 Final Combo 05/01/2015 89 Final Combo 04/23/2015 39 Final Electrical 03/25/2015 14 Frame/Steel/Bolting/Weldin 03/19/2015 11 Ftg/Foundation/Piers INDUST Inspector Act RI PY AP PY NR RI PY NR PB AP PY PA PY NR AT&T CELL SITE-REMOVE 8 EXISTI ANTENNAS & INSTALL 12 NEW ANTENNA Comments FIRST AM APPT CALLED JUAN AND LEFT MESS ABOUT FIRE Friday, May 08, 2015 Page 1 of 1 ' • ' t ~ ' .. : · ... , 0$!W't . !JWAL~O!Wti$ #3.$ ~aoTOYt.lt,TA!C .. tl ~<f 1: ~ ~ i , I, , I 1 • , , , , • • , , ,. , , , . , ·_,-rA ', f~ MPA.lll;l.$ · . '· . . ·,~ .~fft)\L·';,., ,:··, '. ·: ' , . : . ,(.:: : ... ·· : .. . . .. . ' -~ u.. ?Qt~ $lT!:tfl$ '. .. ·.: :~ ~1.Uift:fVOffl(l:S \ ~1( .tf.~ OR.Oot· Ot~IUHG '. · . 'l;JS: Jt®f'$fffAl'ffl!l6 · . . ·::-... •n ·-ar.s1mPAffns .. ' ',,¥-4.. ,, ' ' , ••. _;t:.U; -ffltl'.JfATI'Q 1i , · . . 'f i i { 1 ',,l 'j I I i l l I EsGil Corporation In (l'artnersliip witli (]011ernment for (}Jui{ain9 Safety DATE: 5/6/2013 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 13-1060 PROJECT ADDRESS: 2714 Loker Avenue West PROJECT NAME: AT&T SD0428 RACEWAY SET: I ~ P-P-~· ANT JURIS. D IA REVIEWER D FILE cg) The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: Telephone#: ) Email: Mail Telephone Fax In Person D REMARKS: By: David Yao Enclosures: EsGil Corporation D GA D EJ D PC 4/29 Fax#: 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 ' .. City or Carlsbad 13-1060 5/6/2013 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City or Carlsbad PREPARED BY: David Yao PLAN CHECK NO.: 13-1060 DATE: 5/6/2013 BUILDING ADDRESS: 2714 Loker Avenue West BUILDING OCCUPANCY: BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier cell site revisions Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: 0 Complete Review D Repetitive Fee 3Repeats Comments: D Other D Hourly EsGil Fee TYPE OF CONSTRUCTION: Reg. VALUE Mod. per city D Structural Only ----IHr.@• ($) 60,000 60,000 $499.621 $324.751 $279.791 Sheet 1 of 1 macvalue.doc + • ~ I & ~ CITY OF CARLSBAD PLAN CHECK REVIEW TRANS MITT AL DATE: 04/26/13 PROJECT NAME: AT&T MOBILITY LLC PLAN CHECK NO: 1 SET#: 1 ADDRESS: 2714 LOKER AVE WEST VALUATION: $60,000 Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov PROJECT ID: CB131060 APN: 209-081-32 i /7 T~i~ ~Ian check review is complete and has been APPROVED by the ENGINEERING • -------1 D1v1s1on. By: KATHLEEN LAWRENCE 04/26/13 A Final Inspection by the Division is required L~:Yes ~{]No i---This plan check review is NOT COMPLETE. Items missing or incorrect are listed on 1 the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: KAREN.ADLER@PLANCOMINC.COM You may also have corrections from qne or more of the divi~ions/jsted be/o\/11_. Approval from these divisions may be required prfor to the issuance of a bµilding permit. Resubmitted plans should include corrections_ from all division_s. For questions or clarifications on the attached checklist please contact the following reviewer as marked: --"-- PLANNING 760-602-4610 ; Chris Sexton I ..... ___ , 760-602-4624 Chris.Sexton@carlsbadca.gov f~ ·--~,...., , : Gina Ruiz I ! _____ ) 760-602-4675 Gina.Ruiz@carlsbadca.gov Remarks: ENGINEERING 760-602-2750 - i ;-: Kathleen Lawrence I_ ----' 760-602-27 41 Kathleen.Lawrence@carlsbadca.gov Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov 1-i l I J i ._ __ I (" --- j FIRE P.REVENTlON 760-602~4665 Greg Ryan 760-602-4663 Gregory.Ryan@carlsbadca.gov Cindy Wong 760-602-4662 Cynthia.Wong@carlsbadca.gov Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov ~ ~ CITY OF -CARLSBAD BUILDING PLANCHECK CHECKLIST QUICK-CHECK/APPROVAL Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov ENGINEERING Plan Check for C8131060 Project Address: 2714 LOKER AVE WEST Project Description: CELL ANTENNAS/EQUIP ENGINEERING Contact : Kathleen Lawrence Phone: 760-602-27 41 0 RESIDENTIAL INTERIOR 0 RESIDENTIAL ADDITION MINOR (<$20,000.00) 0 CARLSBAD PREMIER OUTLETS 1ZJ OTHER: CELL ANTENNAS/EQ_UIP Date: 04/26/13 APN: 209-081-32 Valuation: $60,000 Email: kathleen.lawrence@carlsbadca.gov Fax: 760-602-1052 OTENANTIMPROVEMENT 0 PLAZA CAMINO RE~L 0 COMPLETE OFFICE BUILDING r··-··-··-··-··-··-··-··-··-··-··-··-··-··-··--··-··-··-··1 OFFICIAL USE ONLY . ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY: KATHLEEN LAWRENCE DATE: 04/26/13 REMARKS: NO ADDITIONAL ENG. FEES NO CHANGE IN USE Notification of Engineering APPROVAL has been sent to via EMAIL on 04/26/13 -··-··-···-··--··-··-··-··-··-··-··-··-··-··-··-··-··-··-·· Page 1 of 1 REV 4/30/11 ~ «.~<1} ¥ CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 Faraday Avenue (760} 602-4610 www.carlsbadca.2ov DATE: 9/18/2014 PROJECT NAME: Raceway PROJECT ID: MCUP 07-15X1 PLAN CHECK NO: CB131060 SET#: 1 ADDRESS: 2714 Loker Avenue West APN: 209-081-32 [Z] This plan check review is complete and has been APPROVED by the Planning Division. By: Austin Silva A Final Inspection by the Planning Division is required ~ Yes D No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on ___ , the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: margie.sullivan@plancom.inc For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 'ENG'INEERING FIRE,'PREVENTION 760-602-4610 ' 760•602-2750 760°602-466S · ,, ·,· . , ' . D Chris Sexton D Kathleen Lawrence D Greg Ryan 760-602-4624 760-602-27 41 760-602-4663 Ch ris.Sexton@carlsbadca.gov Kathleen.Lawrence@carlsbadca.gov Gregory.Ryan@carlsbadca.gov D Gina Ruiz D Linda Ontiveros D Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov ~-Austin Silva D D Dominic Fieri 760-602-4631 760-602-4664 Austin.silva@carlsbadca.gov Dominic.Fieri@carlsbadca.gov Remarks: /2(~;' """'~I;.~, ~· CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.i;mv DATE: 4//26/2013 PROJECT NAME: Raceway PROJECT ID: MCUP 07-15X1 PLAN CHECK NO: CB131060 SET#: 1 ADDRESS: 2714 Loker Avenue West APN: 209-081-32 D This plan check review is complete and has been APPROVED by the Planning Division. By: Austin Silva A Final Inspection by the Planning Division is required D Yes D No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. ~ This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: karen.adler@plancom.inc For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610. 760-602-2750 760-602-4665 D Chris Sexton D Kathleen Lawrence D Greg Ryan 760-602-4624 760-602-27 41 760-602-4663 Chris.Sexton@carlsbadca.gov Kathleen.Lawrence@carlsbadca.gov Gregory.Ryan@carlsbadca.gov D Gina Ruiz D . Linda Ontiveros D Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov ~ Austin Silva D D Dominic Fieri 760-602-4631 760-602-4664 Austin.silva@carlsbadca.gov Dominic.Fieri@carlsbadca.gov Remarks: Need applicant to submit a Notice of Restriction ' 1 -~ ~ CITY OF ¥ CARLSBAD Community & Economic Development November 9, 2.012 www.carlsbadca.gov Plan Com Inc. Attn: Karen Ad.le.r 302 State Place Es.condido, CA 92029 SOBJ,EC:n MINOR-CONDITIONAL. U_SE PERMIT NO; MCU~ .07-lSxl-Request for approyal of i:1 Minor Conditional Use Permit extension (MCUP .07--.:L5x1); to allow the continued operation and maint~11anc1:: <;>f a·n e!i<i"$ting Wirelass Comm.unlcations F~cility (WCF.) c!t 2:714 Loker Aven.ue West, in the 'P-MZone and Local Facilities.Management Zone 5. Oear Ms. Adler, The ·city PTa·nner has eompleted, a review ofyour·application for a Minor Conditional Use Permit MCUP 07-l5X1 f9r th~ continued oper~tion c;1nd maihten.anee c;>f a, Wireless ·com,ilfynications· Facility at 27:1.4 Loker Avenue West. A notice was sent to property owners within a 300' radius of the subject property requesting .q:>mm-ents r~garding 'the above reqµest, NQ c;ornments were received within the tEtn day notice period (ending on November 8, -2012-). After careful consideration of the circumstarrces surroun.dingthls re.quest~ the qty Pl,ann~r nas qetermin.ed that the four finding~ required for granting a Mi'no.r C~nditional .Use Permit ,can be made and the~efore1 APPROVES this request based on the folJowing·findings·and conditions, Findings: i. Tti·at the requeste,d use is· necessary pr d'e.sirable for the de:ve.lopmeht .Qf the community, -and is in harmony with the various elements and objecfive-s of the general plan, im:ludi,ng, if applit.a.ble, (he ce11ifiep local c;pqst<il program, specific plan :or master plan .in that (a) the use i,s ne.cessary and desirable for the development of the community because of the-beraefit ~nd d~m~nd ·for digital communfca.tJons ang, data transmissions for-bus.inesses, individuals, pu.blfc agencies and emergency service systems in this part of the city; (b) the existing use is consistent with the Ge,n~ral Plan in (hat the Planned Industrial (Pl) Land Use d~signation doE;s not precJucfe. the provision of Wirel.ess Communitation facility (WCF') uses. The existing WCI= is consistent With City Coun'cil P~licy No. ·64, Wirel!;lss Communic!ltion F.acilities, in that it is in a preferred non-residential. location {Industrial zone) and h~s a stealth design, The. projetf s location arid stealth d~sign c.omply with General Plan objectives that seek to maintain and enhance Carlsbad's appearance. 2. That the i;equested us.e is net detrimental to. existing us.es or to uses specifically permitted in the zonf;! in which the propose(/ u$e is tq be locµt~d in that the ';!Xis.ting WCF' is loq~t~d within a preferred non-residentlal location {Industrial zone-) as Jisted in location Guideline A.1.a. of 'City C9uncil 1?9lk:y Statement N.o. 64, and an aspe~ts Qf the WCF e){hibitstealth design anc;I the ·exist1n~ antennas are located behind RF screen walls or are painted to match the existing building color, :c1nd are located in:· an area of th~ rQof that is not Visible from the ground. The Plahning Division 1635 Faraday Avenue, Carlsbad, CA 92008-7314 T 760-602-4600 F 760-602-8559 ® . . . MCUP 07-1§x1-RAC~WAY S0.0438 November 9, 2012 Page 2 WCF use is not prech.1ded py ttre proJett site's 1,mderlying, P-M .zoning. Fur:therrnore, the modific~tion to the WCF will not resJ.1lt in any additional building coverage, does not visually impact the existing site or building de'sign1 as. the antennas Will be painted so that they blend in with the building co.lor. 3. That the site for the prt>p<;>sed conditional use is adequate in size ;;nd shape to accommodate the yards, setbaGks, walls, fences,. parking; loading facilities; buffer areas, landscapin&.and other development fei;ltures ptescribe·cl in this code qnd req1,Jired by the City Planner in on;ler to integrate the use w.ith other t:1ses in the neighborhood in that existing antennas are lo.cated behind RF transparent ·s·creen walls or are. painted to match the existing building, and the equipment r.oom is. located on the ~round floor within the existing builaing. the minor moc;llfi<;?tiort~ ~re de'$igned to blend in with the existing 1:>uilding ~nd· will n9t imp~~t the appearance of the buildin~. 4. That the street system servin& the proposed use is adequate to properly handle all tr:afflc g~ne.rat~JI b.y the proposed use in that the WCF r.eq~ii"es, Pl"! ·averag~, one monthly maintenance visit and .occasional visits in response to operational problems·. 5. That the existing WCF is co,nsistent with 'city Council Policy No. 64 in that it is located in a pr:eferr~d lpcatiqn (lndi.,lstri13l ,~Qne) as listed .in l..oc:'3tlo.n Gi.t.idelin.e P,.1,a. of ~ity ·Co4.n(:il Pqlicy Statement, No. 64 and exhibits stealth design, as the existin~ antennas are completely hidden behind R.F transparent ,screen wall~ 9r are, pai~ted to mat~b 'the exi~ting, bµilding cqlor, and the equipmentoroom is.located on the. ground.floor within.the existing build in~. 6. That the City Planner has determined that the proje·ct belongs. "to a class of projects that the State Secretary of Resot:m::es has found do not h~ve a significi'lnt impact on th~ environment, and it is there.fore categoi:ically exempt from the requiFement for the preparation of environmental dacuments p.µfsuant to :Se:ption 153.01. -·Existing fai;ilities of the state. CEQA Gu1d'eli'nes. in making this determination, the City Planner has found that the: exc.eptiohs 'listed in SeGti'on 153Q0.2 ofthe state CEQA G~idelihes do· not applyto·this pi"oject. 7. The City PlcJnn~r has :revieWE!d ·~ac11 o,f the. exattion·~ itnposect on the Developer contained in this resolutlon, and h.ereby findsr in this case, that the exactrons are impt'>S'ed fo mitigate .impacts c~\Jse.d by or re.asonably r~lat~d to the· project, and the extent an{! the d.egree of the exaction is in rough pr:oporii:ionality to the impact caused by the pro1ect. . Conditions:. 1. Approval is granted for MCUP 07-15x1 as shown on Exhibits l'A"-'tl" dated November 9, 2012 on file in the Planning. Division and incorpor1:1ted herein by reference. Development shall occur substantially as sh0wn unless otherwise noted in these conditions. 2. If any of the following conditions fail to occur, or if they are, b.y their terms, to be implemented and maintained ov:er time, if any of $Uch conditions fail to b~ so implemented and maintained according to their terms, the City shall bave, the r-i~ht to revoke or modify all approvals. herein granter;{; deny or further condition issu~nce 0f all future builqing per.mi:ts; deny,, rev:ol<e, or further condition ·all certificates of occupancy issued, under the authority of approvals herein granted; record a notice of vibli;ition 0n the ,property title; institut.e and prosecute litigat1on to compel their compliance with s.aid conditio.ns .or seek damages for their violation. No vested ' . MCUP 07-15x1-:RACEWAY S0043S November9" :2012 Page-3 rights:.ar~ gained by Develope:r or a successor in interest by the City's appro.val of this Mino.r Conditional Use Permit. 3,· Staff is authorized and directed to make1 or require the neveloper to make, all corrections and modifkations to the MCUP 07~1Sx-1 documents; as necessary to mc1ke them internfllly consisternt and in co.nformity with the final action on the project. Development shall occur substantially as shown on the-approved Exhibits. Any proposed development different from this appro'lal shall re,q:uire an amendment to this appreval. 4. The Oevelopet/Qpera.tgr shall ·and does hereby agree to indemnify, protect, de'fend and hold' harmless the City of. -Carlsbad, its. Council members, officers, empl.oyees, agents, and representatives, from ~ntj agEJinst any and <!11 liabiUties, ios5.es, d'amages, demands,_ claims ari(:I costs, including court costs and atterney'is fees incurred, by the City ad;ing,, direutly or indirectly, from (a) City's .app't0val and iss.uance of this Mil1'or-CondJtTonai Use Permit, (b) City's approval or issuance of any per-mit or action, whether dfscretionary or non-discretibnary, in connection With the use tQntemplated tiereinJ and (4 Developer/Operator's itistctlla,tioh and operation of the facility permitted hereby, indudin~ without.limitation, any and all liabilities arising from the t;?misslqn -bY the-fatility ofelectrQr:nagn~tfo fields 9r ether· energy waves or emissions. 5., The Developer shi;ill cqmply with ,(II applicable provisions offedera;I, staM, and local _ordinances in effect-at the time of building permit issuance. 6. This proje.tzt shall comply with all conditions and mitigation measures, which are req.uired as p~n:t of the Zd'ne 5 Loc_al F-aciliiies: Management PUm and ~ny amendments rnc1Qe to that Plc1n prior to the issuance of buildinij permits. 7'. MCUP' Q7·1,Sx:a shall be revJewed b)_y the City Planner on a yearly basis to determine if all c;o_hc;litions of thi~ pe.rmit tl~Ve _been met ;;ind that the u~e does pot helve a substantial negc1tiv¢ effect, on surroundin& proper.ties, or the public health,-safety and gener-al-welfare. If tbe City Planner determines that: 1) the minor conditional u.se permit was obtained .by fraud or misr.epresentation; ,or 2) the: use for whith such approval is granted is not being exercised; o.r 3) th~ contlitit>ns of gpproval have net been met; or 4) the minor concUtiqnal use permit is being or recently :has been exercisedcentrary to any of the terms sr tronditions·of approval; or 5) the use for which such J1pprc:M;il wa~ granted has Ge!lsed to ,ex!~t or has been susp-eiid.ed for one year of more; or 6) the use is in violation of any statute, ordinance, law or regulation; or 7) the use permit~ed by the minor e::onditiohal use permit is being or has been so exercised as to be detrimental to the public health, safety or welfare or so as to constitute a nuisance, the City Plan-ner sh9II hold ~m informal public 'hearing c,1nd after providing the permitt~e the opportunity to be beard; the City Planner may revoke and terminate the minor conditional use permit in Whole or in part, reaffir.r,n the minor conditional use permit, mo.dify the c-0nditions or impose ne.w condftions. 8, Thls Ccmditional Use Per:mit ls ~ranted for a period 0f 10 years from Novemb~r 9, 2012 through Npvembet9, 2oi2. This petmit may be revnked at any time after a public hearing, ifit is fo_u·nd that the use 'has a, substanti'al detr:imental ,effect on surrnunding land uses and the public's h~aJth and welfar~, or the condit.ions. imposed herein have not been met. This permit may be extencled ,for a reasonab_le period of-time not to exceed ten ,{10) years .u,pon written application of the permittee made no less than 90 days prior to ·the expiration date. The Planning Commission may not grant sach extension, unlessJt finds that there are no substantial ne~ative ' > MCUP 07-15X:L -RACf,WAY 5D0438 Noverilber9, 2"012 JYage 4 effects on sµrrounding lancl u$es or th~ public's health and Welf;,tre, If a substantial negative effect on surrounding-land uses or the public's health and welfare is founc:!, the extension shall be denied or gr:anted with tortditien.s which will eliminate or sub~tantially reduce. such effects. There is no limit to the number of e~tensfons the Pl.anning Cbmmission may grant. 9, Prior to. the issuance of a. building permit, owher/applk:ant shall submit to the City a Notice of Restriction to be filed in the office of-the County Recotdet, subji=ct to tne satisfacticm of the.City P.lanner~ notifying all interested parties and successors in interest that the City of Carlsbad has. iss.ued a Minor Conditional Use Permit on the rear property owned by the owner/applicant. Said Notice ,of Restriction shall note the property description, locati0n of the file containing complete projeGt details and all eo11di~ioos of ~ppr.oval a~ w~II ~s ciny c(;)n,ditions or r~$trit;tions specified for inch.islon in the Notice efRestr.iction. The· City Planner has the authority to exect;Jte and record an amendment to, th.e notice; which mocllfies or terminates said notice upon a showing of gt;>od cause by the owner/applicant or·successor i'n interest. 10. lfanyccmdition for construction of a:ny p.ublic impro\i.ement·S or facilities, o.r the .payment of any 'fee'~ irr-lieu thereof, imposed by this approv~I or imposeq by law on this .residential· housing project are challenged this ap.i;>roval shall be susp.ended as provided in Government Code S~ctioo .690i0. If any sµch c:onditiori 'i~ determined t9 be invalid this. approval shall be invalid unless the CJty council rl.etermirte.s· that the project without the condition complies with .all requirements of 'law. 1~. mevelqper sh~II report;, in writi'ng, to the <:ity Planner withi'n ~o d~,ys:, any ~d;dres.s change from that which is. sh.own on the permit applkation. 12. J)evefqper/Operator shall co.m,plywith the Feperal Commuhication Gommissfon's ,guidelines .on limits for human e?(p0sur.e, to radio freque.ncv (.RF) el~ctrotnagm~tic. fi~lds .• Within sJK (6) month~ after the i!'is.uance of occupancy, and with any· time extension or ,amendment request, the D~velap~r/Operator shall ·suptnit tQ the qty Planner-either (!) verification tMt the prCi>jett is categp.ric~lly e~cluded from having· to ·determine compliance with the RF exposure guidelines per 47 CF-R $1.J:-307(b)(1); or (2}a ·prqject impl~rnentc!tion report which prov'iqes cumul~tiv!; .field measurements of RF·emissions of aJl.ante'f-mas.iostalled at the subject·site. The report shall qqantify th¢ Rf etnissip!)s ~m;! te/mtfare,tlle r,es.1;11):s With the exposure lir:nits ·established by the FCC guidelines. Said report shall be suf)ject to review. and approv:al by the City Planner for cons'istency with the Project'~ pr:eliini11aty report or:\ RF exposure submitted With-the initial project applk:ation and for consistency with the FCC guidelines. If, on review~ the City finds that the Project does not meet the: FCC guid.elin·es, the City may revoke or rrH:rc:Hfy this conditional usepe.rmit. En.gineering: 13. Developer shall compJy with the City's Stormwater Regulations1 latest version, and shall implement best management pr~ctices at all ti'me.s. Best m;:inagement prc1ctk'es indude but are n.ot limited to pollution treatment practices or devices, erosion 1::ontrol to prevent silt runoff during construction,. gener.;:il h,ousek~eping practices, pollution prevention and educational JJl'c!ctices, maintemince procedures, and other management practices or devices t0 prevent or reduce the! distharge of po'll'utants to stormwater, r~ceiving water or stormwater conveyance . .,. MCUP 07~15-xl -RACEWAY SD0438 November 9; 2'012 'Page 5 syst~rn to the m~~imJ;1,n ,extent practicaple. Dev.eloper $hall notify pro~pective owners and tenants,of the above requirements. Code Remanders: 14. Approval of this request shall not excuse complianGe with all applicable sections of the Zoning Ordih~n<;:e ang all other applitabte, City ordinances ih effect at time ofbuflding petmit issuance, exce,pt as otherwise specifically provided herein. 15.. Premise identification (ad~resses} sha'II, be provided consistent with Carlsbad Munidpal Code Sectio'n 18.04.320 .. NQTIC.E Please take NOTl(;E that approval of your project inctudes the "imp0sition" of fees, dedications, res,e:rvatidns, ot·othet ex~ctions hereafter collectiV:ely referred to f9r convenience as "feeS'/exactions." You havf;! 9,Q. ~fays frotn the qate of fin.al-approval to j:>fo,test imposition qf the$e fee$-/exact1ons,, If you protest them; -you mustfollow the J)rotest procedure set forth in Government Code Secti'on 66O2.O(a), i:!rid file the protest and ~my other requirep i'nform~tioh with the ·City Manag~r f,ot processing ih aecordance with Carlsbad Munidpal Code Sedion3.'32:O3O. Failure to time·ly follow that procedure will bc:1r aJWslibsequent legal action to,attack, review, s.et aside, void, or ann_ul their imposition. Yo1,1 are hereby 'FURTHER NOT:IFIW· that your right to protest the specffie.d fees/exactions DOES NOT APPLY to water and sewer conne'ction fees .and capacity charges, norplanning; .zoning, grading or other similar application processing or service fees in conneetion with this-j:>toject; NO.R o:oes IT APPi,::.' .to aoy fees/exactions ol which you have preViously bei:!n giv~n a NOTICE similar to this, .or .a;s to which the ·stgtute e>f Umitat'.i<H1s ha~ ptev,iously·otherwise expirect. This Q,edsion may be appealed by:you or: any other member of the public to the Planning Cbm,mission within ten days of.the d,ate of tb)s letter, Appeals must' pe submitted in writing to the Pl;rnrting 0ivi'sJpn ,ft 16:3:S Farai:l~Y' Averrµe in Ca.rlsl:?ad,alo.11g with a payment ,of $6-3ftOO. The fillng of ;5uch .appeal within suc;:h time llrnit shall stay the ,effective date of the orc:fer of the Glty Plann~r µntil $U¢h time as ~ final de,cision on the c'!ppeal is reached. lfvou have any q~estions regarding thi,s matter:, please feel free to contact Austin Silva c;it {:t6b) 602-4631. Sincerely, &vt&4 tt~ ,CHRIS DeCERBO Principal Planner CD:AS:bd c: CBL, LLC'27l4 Loker Avenue west '#100, earls bad, CA 92010 AT&fMobility; 5738 P-acil'lct~nter:Drive;San Pi¢go,CA92121 Don Neu, ¢ity Planner Mlchele-Masterson;Senior ManaijeJJientAnalyst Principal Planner l'roJect Engineer fife ¢opy DMS/Data Entry «.~ ~ CITY OF CARLSBAD PLAN CHECK Community & Economic REVI Ew Development Department · 1635 Faraday Avenue TRANSMIT~f)i, Carlsbad CA 92008 · , Q JJi-EFT www.carlsbadca.gov ·eni!}l, DATE: 6/11/13 PROJECT NAME: Att Cell Site -Raceway lJ.? I'-/ LJ) l<~OA~CT ~ PLAN CHECK NO: cb131O6O SET#: 11 ADDRESS: .&888-armada-Dr-Ste..aeo APN: [8'.j This plan check review is complete and has been APPROVED by the fire Division. By: cwong A Final Inspection by the Division is required [g] Yes D No D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: Karen.adler@plancominc.com (and via usps) You may also have .corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVE"NTION 760-602-4610 1eo-602-21so 760-602-4665 D Chris Sexton D Kathleen Lawrence D Greg Ryan 760-602-4624 760-602-27 41 760-602-4663 Chris.Sexton@carlsbadca.gov Kathleen.Lawrence@carlsbadca.gov Gregory.Ryan@carlsbadca.gov D Gina Ruiz D Linda Ontiveros ~ Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov D D D Dominic Fieri 760-602-4664 .. Dominic.Fieri@carlsbadca.gov Remarks: ** APPROVED: Page 1 of2 THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. TIDS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. *** Bubble All Changes**** 1. Provide sign package for location. If existing, ·please state so but also show what signs are existing. These shall include but are not.limited to NFPA 704 and site contact information. Site contact information shall be relevent now to location. Please update if necessary. 2. Indicate Knox Box location. Provide key for access at the time of inspection. *** If single sheet, this may be slip sheeted at front counter with appointment. Please call 760-602-4662 to schedule OTC for M-F. Page2 of2 Carlsbad Fire Department Plan Review Requirements Category: TI , INDUST Date of Report: 06-11-2013 Reviewed by: {tc 4 }))"\ / J7 Name: Address: Permit#: CB131060 CBLLLC ATTN: KAREN ADLER STE200 580 ARMADADR CARLSBAD CA 92008 Job Name: AT&T CELL SITE-REMOVE 8 EXISTI Job Address: 2714 LOKER AV WEST CBAD I adequately conduct a review to determine co · e applicable co e carefully all comments attac se resubmit the necessary plans and/or specifications, w1Tn-l""'1Elnges "clouded", to this office for · and approval. Conditions: Cond: CON0006321 [NOT MET] *** Bubble All Changes**** 1. Provide sign package for location. If existing, please state so but also show what signs are existing. These shall include but are not limited to NFP A 704 and site contact information. Site contact information shall be relevent now to location. Please update if necessary. 2. Indicate Knox Box location. Provide key for access at the time of inspection. * * * If single sheet, this may be slip sheeted at front counter with appointment. Please call 760-602-4662 to schedule OTC for M-F. Entry: 05/20/2013 By: cwong Action: CO Cond: CON0006391 [MET] ** APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. . THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Entry: 06/11/2013 By: cwong Action: AP ~ ~ CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 5/20/13 PROJECT NAME: Att Cell Sit~ -Raceway l:Jl/): PROJECT ID: PLAN CHECK NO: cb131060 SET#: I ADDRESS: 5800 a,!;ra~~ee ~ APN: z, I ~ wes · PN ~-r D This plan check review is complete and has been APPROVED b?t{hire Division. By: cwong A Final Inspection by the Division is required [Z] Yes D No IZ! This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: Karen.adler@plancominc.com (and via usps) You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602~2750 76Q-602-466l? D Chris Sexton D Kathleen Lawrence D Greg Ryan 760-602-4624 760-602-27 41 760-602-4663 Chris.Sexton@carlsbadca.gov Kathleen.Lawrence@carlsbadca.gov Gregory.R;tan@carlsbadca.gov D Gina Ruiz D Linda Ontiveros ~ Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov C~nthia.Wong@carlsbadca.gov D D D Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: * * * Bubble All Changes * * * * Page 1 of2 1. Provide sign package for location. If existing, please state so but also show what signs are existing. These shall include but are not limited to NFPA 704 and site contact information. Site contact information shall be relevent now to location. Please update if necessary. 2. Indicate Knox Box location. Provide key for access at the time of inspection. *** If single sheet, this may be slip sheeted at front counter with appointment. Please call 760-602-4662 to schedule OTC for M-F. Page 2 of2 ~at&t ~., ~. 2~t~~o~Yo~d~!~~ BLACK & VEATCH CORPORATION 10950 GRANDVIEW DRIVE, OVERLAND PARK, KS 66210 USA +1913-458-7556 I HENEINM@BV.COM April 23, 2013 B&V Work Order: 13842ATTCA-S (Rev 1) STRUCTURAL ANALYSIS EVALUATION LETTER Site Number: 13842 (SD0428) Site Name: Raceway Site Address: 2714 Loker Avenue West, Carlsbad, CA 92008 Project Name: AT&T Turf SD/LV-LTE Overlay Project Number: 168151.8216 This letter is to confirm Black & Veatch's structural review of the building listed above. The intent of this review is to determine if the proposed LTE equipment overlay will have any adverse structural impact on the existing building. The existing building is an approximately forty foot six inch ( 40'-6") tall multi-story building primarily constructed of brick and steel. Currently, AT&T has eight (8) existing panel antennas mounted to the existing penthouse wall. AT&T is proposing to remove the eight (8) existing panel antennas and install twelve (12) wall mounts, twelve (12) Kathrein 800 10764 K panel antennas, and eight (8) FRP skirts at the same RAD elevation as the existing antennas on the existing penthouse wall. AT&T is also proposing to install six (6) Ericsson RRUS-11 RRU's, six (6)Raycap DC2-48-60-0-9E DC surge suppressors, one (1) Raycap FC12-PC6-10E junction box, and one (1) TMA mounted to the existing mechanical room wall mounts. See construction drawings for details. Proposed L TE cabinet equipment and mechanical room wall mounts are outside the scope of this analysis. By engineering analysis and judgment, the existing antenna mounting system, the proposed skirt, the proposed skirt mount, the existing penthouse wall, and the existing building are capable of supporting the final configuration without resulting in an overstressed condition. Please contact Maged Henein in our Kansas City office at (913) 458-7556 if you have any questions or comments. Clara Blauwiekel, E.I.T. ~' Owner: AT&T Computed By: C. Blauwiekel Plant: 13842ATTCA-S (Rev 1) (800428) Raceway Date: 4/22/13 Project No. 168151 File No. 8216 Verified By: Title: Connection Design of Proposed Equipment Date: BLACK & VEATCH to Existing Wall and Skirt Design Page: TABLE OF CONTENTS page 1. PURPOSE 3 2.REFERENCES 3 3. ASSUMPTIONS 3 4. CONCLUSION 3 5.ANALYSIS 4 6. ATTACHMENTS 10 E. Owner: Plant: Project No. Title: BLACK & VEATCH 1. PURPOSE AT&T Computed By: 13842ATTCA-S (Rev 1) (SD0428) Raceway Date: 168151 File No. 8216 Verified By: Connection Design of Proposed Equipment Date: to Existing Wall and Skirt Design Page: The main purpose of these calculations is to design a NewFRP skirt for the exjsting and proposed antennas and to design a proposed antenna mount for the ptopol$ed antennas. 2. REFERENCES A. California Building Code, CBC 2010 B. Telecommunic:ationi;; Industry Association, TIA-222-G C, AISC Steel Construction Manual, 13th Ed. D. Construction draw{ngs by Black & Veatch Corp., dated 03/26/2013 E. Dynaform FRP Structural Shapes Design Guide 3. ASSUMPTIONS No major assumptions were made except as those mentioned in the fore~oing calculations. 4. CONCLUSION Use two 1/2 inch. A36 threaded Rods at each connection. Use 3/8 inch FRP bolt conections Use 1/4 inch thick FRP Skirt Panels See redline sketches for details D. Owner: AT&T Computed By: C. Blauwiekel Plant: 13842ATTCA-S (Rev 1) (SD0428) Raceway Date: 4/22/13 Project No. 168151 File No. 8216 Verified By: Title: Connection Design of Proposed Equipment Date: > BLACK & VEATCH to Existing Wall and Skirt Design Page: 5.0 ANALYSIS 5.1 DEAD LOAD AND DIMENSIONS Existing Antenna : MB48RR80YDPALQ Wp 42 lbs Deminsions 53" x 11" x 4" Proposed Antenna: Kathrein Antenna 800 10764 K Wp 40.8 lbs Deminsions 55.2" x 11.8" x 6" Skirt: AssumeFRP Height= 5.50 ft Depth= 1.5 ft Thickness= 0.25 in. Panel Density= 70 pcf Volume= 5.50 x 1.50 x 0.250/12 = 0.17 ft/\3 Wskirt= 70.00psf x 0.17 ft/\3 = 12.03 lbs (one side of skirt) Miscilanious: Pipe Mount, frame AssumeW= 140 lbs Total Dead Load: Proposed Antenna + 2 xSkirt + Miscilaneous = 204.86 lbs / Owner: AT&T Computed By: C. Blauwiekel BLACK & VEATCH Plant: Project No. Title: 13842ATTCA-S (Rev 1) (SD0428) Raceway 168151 File No. 8216 Connection Design of Proposed Equipment to Existing Wall and Skirt Design BASIC WIND LOAD PER ASCE-05 a. Velocity Pressure, Qz Date: Verified By: Date: Page: qz = 0.00256 Kz Kzt Kd V2 I Basic Wind Speed, V = '---/ 8_5 __ _,_/ •___,/ mph = 0.00256 X 1.09 X 1.00 X 0.85 X 85.00"2 X 1.00 Qz = 17.20 psf b. Velocity pressure coefficient, Kz Kz = 2.01 (z/z9)21a = 2.01 (50 / 900"(2/9.5) Kz = 1.09 a.= 9.50 c. Topographic Factor, Kzt K1 = 0.85 K2 = (1 -x / µ Lh) = [1.-15 / (4.0 X 15)] K2= 0.75 Ka= 2.718 (1z/Lh) = 2.718"-(2.5 X 50 / 15) Ka= 0.00 d. Wind Direction Probability Factor, Kd / Solid Sign e. Importance Factor, I Category / II -(V = 85 to 100 mph) Exposure Category/ C / • / ~--~~ Height above Ground Level, z =/ so / • / ft Zg = Hill Shape/ 2D Escarpment Crest Type I Downwind Distance Upwind of crest, Lh =/ 1s Distance Upwind to Bldg Site, x =/ 1s Kzt=[1+K1K2 K3)2 900.00 ft = [1 + 0.85 X 0.75 X 0.00]"2 Kzt= 1.00 Kd = 0.85 I= 1.00 REVISED, SUPERSEDED, AND VOID CALCULATIONS MUST BE CLEARLY IDENTIFIED, INITIALED, AND DATED BY THE RESPONSIBLE INDIVIDUAL. CLAUSE 6.5.10 Eq. 6-15 6.5.6.6 Table 6-2 Table 6-3 6.5.7.2 Method 2 Fig. 6-4 Eq. 6-3 6.5.4.4 Table 6-4 Table 6-1 Owner: AT&T Computed By: D. Plant: 13842ATTCA-S (Rev 1) (SD0428) Raceway Date: Project No. 168151 File No. 8216 Verified By: Title: Connection Design of Proposed Equipment Date: BLACK & VEATCH to Existing Wall and Skirt Design 5.2 WIND LOADS Wind Velocity Pressure @ z = 200' Gust factor: Wind Load on antenna: Antenna dimension: Force coefficient: Equipment Coefficient: Wind load: Wind Load on Skirt: Skirt dimension: Force coefficient: Equipment Coefficient: Wind load: Page: 17.2 psf 0.85 (based on 85 mph wind) B= 1 ft H= 4.6 ft Cr= 1.85 Ch= 1.9 Pa = q/G*CtB*H*Ch = 236.4 lbs B= 1.5 ft H= 6 ft ct= 1.85 ch= 1.9 Pa = q/G*CtB*H*Ch = 462.5 lbs / Controls C. Blauwiekel 4/22/13 Owner: AT&T Plant: 13842A TTCA-S (Rev 1) (SD0428) Raceway 168151 File No. 8216 Project No. Title: Connection Design of Proposed Equipment BLACK & VEATCH to Existing Wall and Skirt Design 5.4 LOAD COMBINATIONS Seismic Factors Loads Sds= QE= Fp= Fp= Ip= Dead load = Wp = Wind Load= Connection Spacing d = Depth= Svertical = Assume SHorizontal = Connection points = 1.113 Q.53 Wp= 108.58 lbs 1.5 204.86 lbs 462.50 lbs 1.50 ft 2.00 ft 0.75 ft 2 1.2 D + 1.6 W (Wind Perpidicular to wall) O.M = (1.2*Dead)*(Depth/2) = 184.38 lb-ft T= (1.6 W/(connection pts)+(O.M.)/(Svertical) = V = 1.2 Dead/connection points 1.6 W (Wind Parrallel to wall) Wind O.M = 1.6*Wind*(d/2) = Dead O.M.= 1.2*Dead*(d/2) = = 555.00 lb-ft 245.84 lb-ft T= (Wind O.M.)/(SHorizontal) + (Dead O.M.)/(Svertical) = V = sqrt [ (1.6 W/ pts)"2+(1.2 D/pts.)"2] = 1.2D + 1.0E (Vertical Seismic)+ QE O.M = (1.2 + 0.2*Sds)*Wp*Depth/2 = 218.58 lb-ft T= (O.M.)/[(Svertical)]+ Fp/connection pts. = V= (1.2+.2*Sds)*Wp/connection points= Computed By: C. Blauwiekel Page: Applied Force 462.19 lb/connection pt. 231.10 lbs/bolt 122.92 lb/connection pt. 61.46 lbs/bolt 4/22/13 Controls 862.92 lb/connection pt. 431.46 lbs/bolt / 389.89 lb/connection pt. 194.94 lbs/bolt / 163.58 lb/connection pt. 81.79 lbs/bolt 125.23 lb/connection pt. 62.62 lbs/bolt D. Owner: Plant: Project No. Title: AT&T 13842ATTCA-S (SD0428) Raceway 168151 File No. 8216 Connection Design of Proposed Equipment BLACK & VEATCH to Existing Wall and Skirt Design 5.5 CONNECTION TO WALL Design New Anchor Bolt Size for Combined Shear and Tension. use 1/2" <I> A36 Thread Rods Design Anchor Bolt Material Type (per AISC ASD 13th edition) Try ASTM A36 bolt Fu= 58 ksi Fnv= 23.20 ksi Fnt= 43.50 ksi Ab= 0.20 in2 fv = 194.94 lbs = 992.83 psi F'nt = 1.3 Fnt -<p Fnt fv I Fnv = 1.3 X 43.50 -2 X 43.50 X 0.99 / 23.20 F'nt= 52.83 ksi use F'nt = ft= 431.46 / 0.20 = 2197.41 psi 2.20 ksi Computed By: C. Blauwiekel Date: 4/14/13 Verified By: Date: Page: per Table J3.2 per Table J3.2 0.99 ksi <p = 2 43.50 ksi < F'nt OK Owner: AT&T E. Plant: 13842ATTCA-S (Rev 1) (SD0428) Raceway Project No. 168151 File No. 8216 Title: Connection Design of Proposed Equipment 6LACK & VEATCH to Existing Wall and Skirt Design 5.6 CHECK FRP SKIRT Wind= 2/3 Wind to anchors = 308.34 lbs Assumefb = Assumefv= Assume Height= Find the Required thickness For bending 15 ksi 6 ksi 5.5 ft Mmax= Wind x Depth/2 = S= M/fy = 0.12 inA3 S= Height x(thickness)A2/6 Thickness required= sqrt (6S/Height) = For shear Vmax= Wind= 308.34 lbs Thickness required = Wind/ (fv x Height ) = Select 1/4 inch thick FRP = 0.25in Computed By: C. Blauwiekel Date: 4/22/13 Verified By: Date: Page: Applied Force Depth= 1.00 ft 154.17 ft-lbs 0.11 in 0.0008 in. Owner: AT&T D. Plant: 13842ATTCA-S (Rev 1) (Sb0428) Raceway 168151 File No. 8216 Project No. Title: Connection Design of Proposed Equipment BLACK & VEATCH to Existing Wall and Skirt Design 6.0 ATTACHMENTS A. FRP Catalog Cut Sheets 8. Site Photos C. Construction Drawings, dated 03/26/2013 D. USGS Design Maps Summary Report Computed By: C. Blauwiekel Date: 4/22/13 Verified By: Date: Page: Below are the test r,~sults for typi(:a) coupoi:-i propwti~s. p.f !SO, !SOFR and VE_FR ~l~t Sheet .Properties are derived per the ASTM test method shown. $ynthetic surfacing veil an_d uJtraviqlet inhil:>itors are standqrd. 120 . 120 120 :.:~t< ,~:i,)~ijf .-< ·.:~ J~;" cl 200 Tunnel Te~t E-'84 Flame Spread .25 max. ~!~i\irifi!l.YEf~? ~ · --,. -< • • • ~. \,f}~s. · . . :, : ::. ·i;[i9QtlYW.irlf' ;>· . ~ M W '-~ ;-&~§~~oig~-~.~!!~m~~r},.E./.. ./: ·,. j~sf),, ,, .... ".( :~Bk~·oil)"slw1t9o~:f@··: :_.~-~: ·-<·:. LW::; Lengthwise www.fibergrate.com I 800-527-4043 CW= Crosswise PF = Perpendicular to Lainiriate Face 9 BEARING ON FRP Bolt A_llowable f<>r Given FRP Plate Thickness (1) " MATERIAL BOLT DfANIETER THICKNESS . ' 3/8" 1/2" 5/8" 3/4" .. ... 1/8" .499 6~q 781 938 C174"· 938) 1250 1563 1875 3/6" 1406 1875 2344 2813 1/2" 1875 2500 312!;; 3750 3/4" 2813 3750 4688 5625 1 •:• 3750 5000 6250 7500 ... (1) BEARING on FRP plate or ¼1eb controls (Factoi' of Safety= 3 .. 0;.Fp=IO,0Q0 psi) The designer niust co,ifirm that no oth_er coinponent of connection controls. BOLT SHEAR 1" 1250 2500 3750 5000 7500 10000 Bolt Allowabl~ for Given Bolt Diameter (2) ' . . BOLT TYPE & BOLT DIAMETER APPLICATION .3/8" 1/2" 5/8" ~1~ss:. sirigle sh_e~r (~) · 1468 2563' .. ~912 31.6SS-double.shear . 2816 5007 7823 rFlfFthreadect roa (4) ~ cs1mJ 600 900 ) . . ~in_gle shear ( " ·• , FRP threaded rod ~ 600 1400 1800 double shear .. .. (2) The designer must confirm that no other component of connection controls . (3) $HEAR of bolt controls. Fv=0.Jl*FU = 0.17*75,000 psi= 12,750 psi (4) SJ-iEA,R of FRP threaded rod CQntrols (Faciorof Safety= 4.0). Ultimate values Ji-om Dynafqrni8 Design Guide RATIO OF .EDGE DISTANCE TO FA~TENER DIAMETER 3/4" 5633 11265 1000 2000 Edge Distance -cl* bolt to END Edg~ Distance -cl* bolt to SIDE Bolt Pitch -cl* to cl* RANGE 2.0-4.0 1.5-3.5 4.0-5.0 RECOMMENDED 3.0 2.5 5.0 * -"cl" is cenl~rllne 1" 10014 20027 2050 4100 EXTR,_1'1 ;,_ .. _· ,. ·_ ~y~,~--~ll_ity List 1 ~--~-.;$iQCdD _,; ·. J L ,NDNSTocifm'.;'." :'11 1 x 1i8 .. 1-1f4x_1/8. 1-1/4x3/16 1-1/2x1/8 Hl2x3/16 1-1i2x)/4 2x 1/8 'ix3]~ ~2x1µ 3 X 1/4 3 x3/8 4 X 1/4 4.x 3/8 ~x1/2 5x 1/2 ~x 1/4 6x3/8 i. I B Series Series Series t....4 · earns 500 525 625 2 X 1x'1/8 ; .· ' . 3 x 1~1/2 x 1/4 4 x_2x 1/4 5~1)2x 2-1/2 X 1/4 6 x'ax 1/4 ., 6.x·~idis .6X4 X l/4 Bx4_x'3/8 Sx4.x1/2 10 ic 5 x3/8 10x5x1/2 1~x6x1/2 18 X 3/~ X 4~1/~ i< 1/2 24 X3/8x 7·1/2 X 3/4 ..,·; -,• ...i.,. ,,-~ ~· ' : ~iic1/8 ' · ·"· : 1~1/4 x 1/8 1-1/2x1/8 1-1/fx1(4 1-3/4 .x 1/8 1·3/4 X 1/4 2X 1/8 2 X 1/4_ 2-1/2 x 1/4 3X 1/4 3.'.1/2 X .140 4x 114 5 X 1/4. 6x1/~ 6x 1/4. , •.;-..--.~~-------1 it • ..:,' ' -.... ,.' ,·'' ' ... ----., . -·--'" . _. __ .,_;, -.,.. ~ . -' -~ ' .. , _ . .,,' .,, _._ . -~' -. · 1/4 · 5/16 . 3~ ·s s · ·: 1n-·· 5/8 . ··s .-, s s 1i2 . 5/8 3/4 13/16 7/ij 1 1-1/8 1-:114 1-1/2 2 s s $ s ~--\ ·:.if;: s ,ifr, $ .:-t.~ -----· 1 FlBREBOlT0 Studs and Nuts _ala s·· 1/2 S 5/8 S 3/4 S 1 S · tioJE:·Ai1 FIBREBDL~is· stocked In 4'·1engths. , ' ~/4 1 . 1'1/4 '1-1/2 l. ·. N ,._ s 1 Special Composite _ Deslun -Not EXTREtf' Composttes; Therm.al cure bars and rods were not designed to be machined. NOTES: Unless otherwise noted, all dimensions are In ·1nc~es. -· All EXTR,l;N" Series 500 products can be produced to meet NSF potable w_ater standards In minimum ml.ll run quantities. OriTy products bearing the NSF'logo are certified. ~ . ,. ..... ,, ~--·--~ .. ·," ,i!l:,r,·· -~~ EXISTING ANTENNA SCHEDULE l~,;~t1=~~. ~~~,-~:;~;. '::·'· ~~: ::::·· -;:.;,;.:r~°f-; f~ " .I -+ 01 u: -:::dt L ___ ,_ f-·1,, :i: ' :I;· , .. J'I: -,_51 iu·· .. !; I !;~( ''' ;:i ''' // i 'I ,/ ~:· •. f.Z/:..'. • •I • 4' ,1• "'•' .ii•,,. G::)_ ,,, ...... , ~ -r:.-.u '.rv! /,. lj --'I I Vt--&'.,-~ >,{ If} I ]YJ '{) 4,: -:u,;..11,1.·--·?;\::r- /----·--ii}@! i · • 1 Ui 11; ,, I'' /~/ ,O" /It •r..~· ·--· f ·--. is:D --,: ~:-:.;.,::· ~tt/ ~JJ-c:;·--,;@, ~:; :j_: f:· f!i ; ' :: . 1---...: ' ' : ' :~µ! \.I , ' ' 'I I/: ''/ /1 ' ,: l I ;·~T ,,_,.IJ,>,-· ·r,·.,, i-,,, ,(, }JJ_,,,,:. +-....... __ !...___, _ __:·:::_ II -ff, l'·•I' 1,,.,N<'· G::)_ / ,·1-• ., •• ~ ~ I I ~;/_.:_:1._ ; .. 1,/ ,, ~-l ·-l ·1· · -lt ~ 1--·---'~ _ _j_ __ ~ • w e ~-::: .-:.. ___ :_: .... ~:--:----~ ,:___ 7----=1--~::::I:;--+ Jr··-.. ::-:-.,,,_ . ,. ,: ' ·--... . ,if[ ANTENNA LAYOUT (EXISTING) 114"•1'-o" SECTOR ' A 2 J 4 ' 8 2 3 . 1 0 C 3 4 ~ AZIMUTH ',-' ',. ,,. 75' ,. ,;s• FINAL ANTENNA SCHEDULE MODEL NO. ANTENNA TIP RRU COAX CABU: FIBER/COAX CSRf' JUMPER HEIGHT LENGTH ±5' LENGTH ±3 800 10764 K ~ 8uu 1u764 K 46'-o" 7/15' 130' 19'-rt HOO 1076,t. ROQ 10764 K ~ 1u7&4 K RRUS-11 600 tn76-4. K ,t.6'-o" ~ 7/15' 1JO' 19'-o" BOO 1n754 K 600 107&4-K ~ 600 10764 K ~ BOO 10764 K 46'-o" -7/15' 130' 19'-0"' 800 10764-K 00 1076 II' ~ r;.+ ,-·-,t' 11,V, "'1l1'/.,,I ,,,, /I ,, ,/ ~ i~',/. (N)RRU~ iJt; S 7 I ' (N) SURGE ~ ,, •).,' ' 4 (N) --f-·· ,,., re:;,: --, .. ,::; '/1! ' /ISi:--.....__ t •.lN ; ;,'!VSUPPRESSOR~ RAU~ 1 11; @fii}(N) SURG~~.; N -•1 1 , ' ,._7 SUPPR<S b, /':,-Ii ,,:. .., ' • i I'' I l1/ "·•>" or ' / I I I/ , 11 '·-''-1.~ ~:V (N) LOCA~TION -__ 11:~I ,.~ JI/ vt. • L (E) 1MA. ' 1,/.J I I•, ~.,, .,,,. L_ /;::'JflJ.d (E) 4'-4~ ,'JIITEt,IMA. TO BE ~EPlACED WITH (N) 4'-f mr I ;1-;--. a~"?J":,, SK<RT, P~NT .,,:""LL'\ ! fl: I (1YP OF 4) TCH THE (E) SURFN:E~ • ..,i __ _ !!111 • i'_ ----1 !f i ~~::~ i ;;/ (TYP or 2) 1··--f--(0 4'--4"' ANTWN,t,,@ ld BE. REPI.ACEO WITH (N) 4•-T ,._7 ANTENNA. (lYP Of' 2) 1 J.;. -·--• .__r Vfl'..-.'\.• ·1 @(N) SURGE: / -J /;·:;~) _C,, ~-I jl 1 -,,.~'J WI! i< A-7 SUPPRESSOR ! .,l, t•1 .,, --,, ',, '''di ·····1g!..---lN) .~, ,',;,!i: .. ,.H-~~ ~·~:I/ ~ ;~:,:·:·:, ;~! ·-·-~;1tJf' i1 ,J/: ~ ;--.21i1 , 1,i ~ ' . 4 ---1,1--(N)RRU ~(N)RRU • ~/ iJ ~ -.!;,,,r-·-.. ~ ~·-•t, "' ',•"1-!;lf , ..... • ff W E , •~' ,w 1,: ,,t L; ·-I---.·-:: N) 4"-7" ~~DARW!JH (N) 9 £~N) RRU ' ~.~it~•:;,_,'!;/-}~' (E) \E!J 4 A-7 SURFACE O'fP ~ tiif!i} ,_, • ' • 7 (N} SURG1)R ",-7 A-7 (N) RRU ,._ 7 A-7 , N) i~~ SlJ1'PRESS ·. GYu ., =-;, ~ [~·'<0 0~; ''" ,,S 4-=@ -------1::M ___ ---~-----. --.... ,,-----~----.. ·_c ~ , .. =-.., ·--·" = = ~ ' ~ :;,. r "''"'· = (E) 4'-4" ANTEN(N) 4'-T ~ d§ P~ (E) SURFN:E NA TO BE ' .. "":li'~%""rnikN 10 W.TCH ~~=~:.-:a,,,. ~ ~~ TH£ ~~~T~E (E) SURFACE ANTENNA LAYOUT (NEW) 1/4':1'·0" ~at&t ~-- 57J8 PACIFIC CENTER BLVD SAN DIEGO, CA 92121 la BLACK&VEATCH 10950 GRANDVIEW DRIVE 0\/ERl>.ND PARK, KANSAS 66210 (913) 458-2000 PROJECT NO: 168151 DR.-\WN BY. AW CHE.CKED BY: MH o I 04/111/1.! I IS'SIJEDroRCOliSTRlld,ott JU.VI DAT£ IOESCR!PllOff IT IS A VIOlAllON Of' I.AW FOR Nrc Pl:RSON, IM.£SSmE'fJ.REACTH)lJtURnt£DIRtCTIOO Of-"AUCfHSEOPROF£SSIC»,l.'OtQNEER, TON.'fEltl'MISOQCUt,IEtft, SD0428 RACEWAY 2714 LOKER AVENUE WEST CARLSBAD, CA 92008 LTE OPTIMAL SHEET TITLE ANTENNA LAYOUT (EXISTING & NEW) SHEET NUMBER A-4 ~ b ~ --< ntr.Q~t a u·-rr ACt. ,. ~ @ (C) 4'-<' Nft'[HN,\ stetoR CTOB£REl"U.ClDWl?li (H) 4'-i-Nfl[Hffotr. " I ---I I I @(H)IUN 4-<"' N-nDW, SCClOR C TO et @ R£PLACm vrrm (N) 4' r ~ '1111TH 2 7 N} fWP :SXUU. PAIHT p,IJbC BftO'lliltf 10 ,._ ..,_TtH {Q SURFACC .;..:;,-;;,~1;;;r;::1::,: I I I I I· l;-:-1 I I " I ' }!__:_ <' , I ,/ I ·' 'I ,. I I I I ; f (_ @~at&t ~ 5738. PAC!FlC CENTER BLW SAN Df£GO. CA i2121 a BLACK&VEATCH 1og50 CRAHOYIEW DRIYt ~i,~r:se~~ ea210 PROJEcr NO: 1SS151 CRAWN BY: AW CHECKED Bf: "" NORTH ELEVATION r ,. 1 I I ,~ . .,,: Ir I A I I I I {N) •·-r Nll'DIN4 wm1 (N) tit? s,mn, ~ ~ ;:"'".:?bTOiTI<E (Q 'El7 'El7 ([') 4'-&"' ~ lO BC RO"IJ.C£D WITH ½(N) .\'•T N-IT'CHM Wffll'(H} ntP Sl(•lff, ~ PNHr twtK MOWN m MATQf 1lfE (E) 'El7 SUWACC (ffl' or 2) / (H)4'-T-@ S<CTDIIAIIOU!<!tD 80f10 (E) SCRfIH WALL ,-i tH\ SCCTOR B IMD.l'tA ------,---------,111 --___,,,,,,,,,..-1\11 .,,~.,n:=!, ~, -=!.;--{NJ,M.C!011 9 <MU<"' -~ ctN • 43·-a 1ft' ACi -.. ~....... ~~~-~. ~---~ $ $ $ ~~"o.:~9~ ~ SOUTH Et EVAJIQN ,. ,~r~ B t l.:K/1'/ll(~t'l'.W'I~ 11:C\1 l e.,.n: I toCJlllllON C\'IIAw:lr.AtlQ!rfDfl.Mf'Dll:N«P'OtlOI(, ~A~~~ TOIUillltllDOC1.1111M. 5D0428 RACEWAY 2714 LOKER AVENUE WEST CARLSBAD, CA 92008 LTE OPTIMAL Sffro TllLE SITE ELEVATION SHE£r NUMBER A-5 ..... ... .... .. ' ... 0 ~ u I .. .. IU ill ~ i ll 11 ® ~ 3 flr j ?, iii ~ 1tj ~ I, :ah; r,,ia Ii~;;~ I J1 Mj;g ti~ i. ~"'H Jm11 "" •• r ~0 ailli :I, ,, Lii MB48RRBQYDPALa M.."'OLIL W.L-t~ l.ff., RA&Xll,ll: CDtDR. LIGHi c~n Q'-(C,6Q,_!i. H•W•tl: 1.lol7oJ:'i~•:?0~'1'1 (~J"•ll~•,n \YL.<CII , ~I II P>fL U~N Lil Ul.f.\CI\!, ,5. '4,l 11>1 WNO LONJ, tilCN"AL/IAlLh~/Rl,\1-1 SOC .c.z ffl/., tw>H) 9l 101 CONNCC:'o-1• G,7/lC txt. rcw.u: (E) ANTENNA SPEC!FJCATJQNS BICSSON RRUS-1 1 MD1$10HS, w-dldf: lWER COHSUl.lPOON: lTAl. 'WEICHT: llPEAATIJRt: 4ll•1112a500rnm (tTs7,'%'1111.T) 20CI WAUS ., In -4D'TO~C ~ -11 ,I __ "-:zc::IC ~~ ,-~i l.!L1 HOSCAU: t ,,. KATHREJN ANTENNA BOO 10764 K PJ.001,4£ "-'TIR:Al: CSP AADOMECOWR: LCKtCRtY D.lliENSX>NS. HitWl:0; 140Jal()(b:152mm (M.r-11.a-.6'") ~. W'mf POC-MOUNJED BIW)t£TS: -40.D ~ WlHD SUfMr'>L AAllHG 1:.0 ~ ~ 7/115 004 Ftl,W£ 1 ll,,u,,~B IN} ANTENNA SPECJFICAJJONS NO>clU: I 2 RAYCAP DC2-4B-60-0-9E VOI.TACE PROTU:'OON RATING; ~ W.o.H: 21J:dW&260mm (10.'"•Ll"•10.l5") NC&tl~ ~TINO VOltAGC: "8 VOC NOlr.f.W. OISCt1AACE CURKOIT: 20 kA. a/2'),.a IMXllilut.l DISCHARCE CURRDIT: l",Q IA 8/20,q I.WWIIAI COH1KIOOS OPERATltiC VOlT>a: 75 VJ.C, too VDC ,00 V tu 15 lbt: ,.... I tirn {~[~ Bm1"'"'®"'~ tJ RBV SPECJFJCATJQNS NO""-'l.£ 4 'ff' U';ff _1• .. 5" _ __._ , _lf __ M;f!. CILUWICI: tm') I (TIP) I I {r<P) I 1-I !!!I! .. RRU WALL MOUNT DETAIL ,.t-,.. 1/~• sa.t T"'1'JNC SCRtW e """Sl\lO(nP},P!IOYl>C CCNTINIJOUS su:0HE e """"1MOUl'IIII (N)SURCC~@ ,j...-tl) i!lll:>NV' ~ F"t;'-'J'Ci \lt..U. HOSCOU: 7 pc SURGE SUPPRESSOR DETAIL RRU MOUNTJNG DETAIL NOSC.U: I 5 DOl.T it.S:SlM!JlY TWO-P(.CE ~£1 (m' Of' 2) U~P100C1Jwmt P101ZS QWNJ. HUTS OR r.DUNIJ.Dlr (m'.) (f.l)mCSSOHRRU BOlT AT 2'-a" SPACIIJ NOSCU 8 (H)CPS""'°'"" :.r~tM~: ca-LY PIPE {H) P100QT UNSfflL/f to OOEkD BETWWl s:ruos CONOOT CUMF' (TYP) COHTIHUOUS B£AD OF' SIUCOHE SEAL£NT e ~ Clr.TDI NEOPIIO£'flri\SliE11 eN<QtO!t(m'} t/1o·• Stl.F ;~ S:ClltW TD A "N OF (a) sruos 1/r• COAXW. WU: ----------(t)r,u,'I\AL~ (N} GPS ANTENNA WAU MOUNT ND!ICAI.E RAYCAP fC12-PC6-JOE DIUOtSIOHS.hl>dt. 4.11'1Ma-31itmm (UI 1/1t•s1 5/ll"11!l 1/2") 1& 1/~ ![I I 15 1/4"' -.. •D.313"~1 ,.. I .. ~ . ;:;-r ' . :? f!BER-OPTJC & pc POWER CONNECTION JUNCT]OH BOX .N2I...J&Ell. (] g !I/fl" I·.,,~ I 0] """""' HOSC,,U: 3 6 9 .~at&t ~ 57.18 PACIFIC CE.tfl'ER BLVD SA.N DIEGO, ~ Sl2121 a BLACK&VEATCH 1M50 CRANDVI~ DRIVE ~~1~r&~ e&210 PROJa:r NO. 1aa1s1 DRAWN BY: AW CHECKED Br: IAH D 104/11/IJjme.Gf'D't~ lltV tl.ltt Jaaa.tlDN rf ti A YICUnQI( 0" UW tall Nff POtl0k. lal.mnta'Nft.ltTN:JUaot'nCDfCfDt WAUCl'Jcm2~~ TO Al"Dt TIii DOCWOO SD0-428 RACEWAY 2714 LOKER AVENUE WEST CARLSBAD, CA 92008 LTE OPTIMAL SHEET mu: SITE DETAILS SHEEr NUMSEII A-7 J (E) METAL CAPPING ix, ti 7 1/2" 2 1/2" (N) L4X4X1/4 A36 ANGLE (TYP OF 2) (N) 1 /2"1!1 U-BOLT (N} ANTENNA FRP SKIRT, BOTH SIDES (E) METAL STUD (N) 4'-7" ANTENNA @ 16" o,c, (E) (2) P1 OOOT UNISTRUT MOUNTED ON (E) WALL i= I= . "' I in N ~.~.lrlN-~8"1!1 MOUNTING PIPE (FIELD VERIFY) (N) 1 /2"1!1 A325 BOLTS (lYP OF 2) . IX) ti ar=====~ I 1:i (E)PLAS~ FINISHED ~ '--~~ l~(N) FRP CHIN SKIRT I= i= I= (FIELD VERIFY} (E}8"X2 V VENEER o~f 2" BRICK / I i= R PLASTER_/ t= i= i= ANTENNA MOUNT & FRP SKIRT DETAIL r--- i--:-; I (E) WALL @ 16" cc 1/i; (E) METAL STUD /j_(N) P10DOT UNISTRUT (N} L4X4X1/4 A36 ANGLE (lYP OF 2) II: /I l I l ~ s'-8" ANTENNA ANCHOR DETAIL BEHIND FRP SCREEN (SECTOR A) PAINTED TO MATCH (E) NOTE: VERIFY FINAL ANTENNA MOUNT PRIOR TO FABRICATION OF FRP SKIRT. l NO SCALE I 13 .!l A-8 I LI ~ CI) - r--- r--- f-- I t \\,_(N) 4'-7" ANTENNA (E) FRP SCREEN I NO SCALE j 16 [><I\ r--~---ir--rr---.--=r"" (N) 1/2"<1 U-BOLT 1 I r----:::;nl (N} L4X4X1/4 A36 ANGLE (lYP OF 2) +Ir~ (E) (2) P1 OOOT UNISTRUT MOUNTED ON (E) WALL ix, ;tt IX) I I I I I I I I I I I (N) UNISTRUT P4100 {lYP) llJr I I I __.,.....--(N) 1/4" FRP l O = 0 i....--------PANEL I·· I I. J1 i: 1: I ,I' r I I I r ~ (E) 2-3/8"¢ ANTENNA MOUNTING PIPE (FIELD VERIFY} I ) 11 I I I~-i II I I (N) P1000T UNISTRUT MOUNTED ON (E) WALL (lYP) (E) (2) P 1000T UNISTRUT MOUNTED ON (E} WALL (N) L4X4X1 / 4 A36 ANGLE (TYP OF 2) (N) 1/2"¢ U-BOLT (N) 3/8"¢ FRP I 11,' BOLTS (TYP) ~~ -------------- 1"± I {FIELD VARIFY} ANTENNA SKIRT SECTION (E) WALL -------.... (N) ANTENNA (N) P1 OOOT UNISTRUT ----...,.,,11,b (N) L4X4X1 / 4 A36 ANGLE (lYP OF 2) (E) P 1 OOOT UNISTRUT MOUNTED TO (E) WALL, L=12"-- (E) P 1 OOOT UNI STRUT MOUNTED TO (E) WALL, L=12"~ (N) L4X4X1/4 A36 ANGLE (lYP OF 2)---- (N) 1 /2"1!1 A36 THREADED RODS (lYP) ---~ (FIELD VERIFY) I l!. ~ (N) P1000T UNISTRUT----~!Y:"!,=dl;JJ, '-- (N) 1/2"¢ U-BOLT (TYP)---.....U.----1.Jl:r---=-=' (N) l2X2X3/16 FRP ANGLE NO SCALE ;,. . "j" .... . "' ;,. I in I SECTION -(E) FRP SCREEN WALL J NO SCALE I 14 17 =jll (N) 1 /2"¢ U-BOL1 I (N) L4X4X1/4 A36 [l=l'='ii'=a;.,......,a~-r- ANGLE (TYP OF 2) - 1 Ft---,-....... "r"'~4'" {E) 2-3/8"<1 ANTENNA MOUNTING PIPE (FIELD VERIFY}=---------+k (N) UNISTRUT P4100 (lYP) ~ (N} 1/4" FRP ~ l l l PANEL _________ ,~1---~~~ l o~ 1c in .I in .I (N) 1 /2"¢ A325 BOLTS (1YPOF2)~ (N) L4X4X1/4 A36 ,lit~t:::a::£:$: ::to!@-----+ ANGLE (TYP OF 2) lf t T r i- (N} 1 /2"¢ U-BOLT (N) 3/8"¢ FRP BOLTS (lYP) ~ 7" I 7" I 'rt> .I . 0, . "' I in ANTENNA SKIRT ELEVATION I NO SCALE J__ 15 (N} P1000T UNISTRUT MOUNTED ON (E) WALL (N) 1/4" FRP PANEL--- [ 7J L!Ll Rv J 1" 9" (N) 1/2"¢ A36 (MIN) THREADED RODS (N) 1/2"<1 A325 BOLTS (lYP OF 2) ;fl ~----*""~----(E) 2-3/8"¢ f ii< !!;! ci s {N) UNISTRUT ANTENNA MOUNTING P4100 (lYP) --------IJ-..I PIPE (FIELD VERIFY) ~ 'EJ A·--, l -1'-2" ANTENNA SKIRT PLAN ' I NO SCALE 1 18 -~- ~at&t ~ 5738 PACIFIC CENTER BLVD SAN DIEGO, CA 92121 IDQ BLACK&VEATCH 10950 GRANDVIEW DRIVE OVERLAND PARK, KANSAS 66210 (913) 458-2000 PROJECT NO: 168151 DRAWN BY: AW CHECKED BY: MH 0 I 04/23/13 I ISSUED FOR CONSTRUCTION REV I DA'IE I DESCRIPTION IT IS A VIOLATION OF LAW FOR />NY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SD0428 RACEWAY 2714 LOKER AVENUE WEST CARLSBAD, CA 92008 LTE OPTIMAL SHEET TITLE SITE DETAILS SHEET NUMBER A-8 EUSGS·· Design Maps Summary Report £rin.!; Vjew Detailed Report User-Specified Input Report Title 13842ATTCA-S Thu April 4, 2013 14:33:11 UTC Building Code Reference Document ASCE 7-05 Standard (which makes use of 2002 USGS hazard data) Site Coordinates 33.1325°N, 117.25944°W Site Soil Classification Site Class D -"Stiff Soil" Occupancy Category Occupancy Category I USGS-Provided Output S5 = 1.113 g S1 = 0.422 g SMS = 1.174 g SMl = 0.666 g MCE Response Spectrum 1.20 1.08 0,!'j6 0.114 01 0.72 --~ 0.60 0.4B 0.36 0.24 0.12 0.00 +--t----t--+--+--+----+--+--+---1----i 0.00 0.20 0.40 0.60 0.90 1.00 1.20 1.40 1.60 l.BO 2.00 Period, T (sec) -Cl\ 111 Ill Sos= 0.783 g S01 = 0.444 g Design Response Spectrum 0.99 O.BQ 0.72 0.64 0.56 0.49 0.40 0.32 0.24 0.16 0.08 0.00 +--t----t--+---+--t----t--+--+--t---1 0.00 0.20 0.40 D.60 0.BO 1.00 1.20 1.40 1.60 l.BO 2.00 Period, T (sec) Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject-matter knowledge. Page24 ·EUSGS Design Maps Summary Report .erLo.t View Detailed Report User-Specified Input Report Title 13842ATTCA-S Thu April 4, 2013 14:33:11 UTC Building Code Reference Document ASCE 7-05 Standard (which makes use of 2002 USGS hazard data) Site Coordinates 33.1325°N, 117.25944°W Site Soil Classification Site Class D -"Stiff Soil" Occupancy Category Occupancy Category I USGS-Provided Output S5 = 1.113 g SMS = 1.174 g SM1 = 0.666 g Sos= 0.783 g 501 = 0.444 g Cl ra Ill 51 = 0.422 g MCE Response Spectrum 1.20 l.OB 0.% 0.!U 0.72 0.60 i:u.a 0.36 0.24 0.12 a.oa +--1----+--+---+--+---+--1---+--+---+ 0.00 0.20 0.40 0.60 CJ.EiC 1.00 1.20 1.40 1.60 l.110 2.00 Period, T (sec) - 0.BB 0.B0 D.72 0.64 0.56 C,, 0.48 ~ 0,40 0.32 D.24 0.16 0.08 Design Response Spectrum 0.00 +--t----+--+---+--l----+--+---+--1-----1 0.00 0.20 0.40 O.GO O.BO 1.00 1.20 1.40 l.GO l.BO 2.00 Period, T (sec) Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject-matter knowledge. Page24 .. _1-f/-lMBf>-000'70?,,- l)EH?.-o 1} . l::"Q _ ,,,. ,,,. f-{iAf r/J-2,0 v tt 7 u IJE.H v<>6 '7 SAN DEEGO REGEONAL Srnll428 HAZARDOUS NllA TERIIALS QUESTIONNAllRE BPlll'AliE 0~ l!ISE «lNlLW U~IR?'t# ______ _ m~ffe.---,,:--..,.--,,-,--=----:-7 't /I .2. \3 11;2.01\ lrelerpltlm.me# IID!lsim-ess Camt'a£1! ca1!1rnw caistlillmi 92.Si 823-$$9] X llf'lroljj:leltAcltllress ; 2./11141 ILOm:JElR A.'wBJ.llJJli: WIESF ZiJi!> Olde Al?!Ni# 9'?,m©.Sl i 2li19J.(il&ll~-e:Gl ! Mailflll@A1lilllliess Zffll) Olde Plalm !File/# i P.O. l!mx 511195,, IRIOOml! 3IEID)00 94583-I ' !Plrerjjaelt Cmmtta&lt i IE[&efilhl Raitmmez ,r efefjUITame t# 11. 2. 3. 4. D ~ 5., D l!8IJ 6. D ~ 71. D IP.Sll 85iS 886--3121 x M.. lt!EALlil!ll-lifAZAROOUS lm!A1lElilli\LS mtl(SIONS D. [ftll!e SlilS«elito ri1i1W Glli!llte ~ Ml3.1siials 1Dt-:1fsimm\, 5500~en1amm1 A.vemie.. Smite 111to, Ssmi rn~. CA ma IPnliedt ~ n:Iare:: 511!M3 IE'xJiiede£ll lilafe lilfO~ey.: 59116/13 tfan-lilew'~Slill Clllrlielililml'elimg profem:J Is JQ1Ull' limlsiness trs!ed e1111 !#le !lelleiS'e sfl!l'e Gllitltlis fEDmlm? {diteti:k all! tllra!t awJi]l,"J))., WllliJQ1Ull' lltlusirness i!li'sptise lilf ~us~ m M'elilfcal'Wasteflill amw em.mun!/? wim ymnrEm!sfness stmre or llTamlJe li-l'.azalioou1 ~ nm lll,lllalilliilfes eap!JEll tmi or~tilan 55 ga:Jlirnns. 5€10 ~ zoo cmm:: rea,. err camcineg~ve tmcims illll amw ~llf1 Willi ym;Em!sfmess wse alJ1l existing C!lli" iinsl'alll an~ slta!rrase lmlk'? Wll! YlD.tllll' ltiwsimess stme Cli lhimdie JReawf.a!ed &mt!amltes (Cal'ARP)f? Wllll ~ blt!Simess wse filrrililsl!a!E a Ha2al'dlllUIS Waste TamEt systernn u'ftll'e 22. Alltfu:l'e 1111J,}1? Will y,IIUirr hl!Si.ll'less stere petroleum in talilks err ioom!ail/!E!IS alt ~facility dJi a ~ fadlify stlflrage capacity~ to IIlll' sreater ll!mll 11,320 gall=? {ICalimmiai"s Ab~ Ellimle111111111 Stoia!te Adi). IDate td'als 0Ca!'MP~ II PART lllll: SAN DIEGO COUMTY AIR FOUlfflON CONTROL msiRtC'r: [ff IJ/Je atlswe/1' tc ml.)' fillf t8te quest!ioos below is yes, applicant ffi1JSt ~ tll!e Mir Pelll!itfefi1I Cmmlnllll lllisl:Hid (Alf'CID), 11)124 CJtili Grow Road,. San IDiego,. Cl\ 921131-1!6491,, Wepljmme ta5S) 58&2600 prior to the issuam:e of a l!!lil'dlmg as-rlem!llimmi pemrml.. IN:cl'e: mi Ire amsweir to queslitlms 4 ar 5 ts yes, applicamt mmt also Slllflmit an asl!Iesttos liNIOO'tatiorrn form to ttte APCO at feast 10 wmking d¥ POOi!' to Cllllilill!llterrdirrg d'elmtel!mln Clll1' reoovatl"ol!T\, except demoliticn 01r renovati'oiai cf resiltfertl!ial sJrucflures Glli femir 1wnits air less. Contact !he APC:lil for more iiafumG:1fi'.£ln. VES NO 11. D 1811 Wlll!hes AJ?ro , aff, am lire li'slt fillf typiE:all eq!UiJl)ment requiru:ig an APCO pemlit on tJte re'il6Se silife of tills from. ifynu hmle anyquesrums}. 2. 0 IP.Sl) {ANSWER OlllllY IF QUESTION 11S YES) Will tlite Sl!Jbiect faa"Ily he flllG!teil IMtllfun 1,000 reel ofthe outer ttoundaly of a sdrolll (I< lmrugh 112)? (Seaidli tire California Sdtool Oirectcry at hffp:/k.\Wl.roe.ca.g:m~ f<llr lj11llfllTo: am pnwte scltoofs or contact the appropti.ate sdrool d!smd}. ! 8 IP.Sll Has a Sl.fM:Ybeen peribmted to detemrme tiite presemce off Aslleslta!s ICemaiiliMg Matemrs? IP.Sl) WIii there he ireoovalion that in.votves iramlling of any mahle asbesll!ls ma.te.iafs,, or ~ing any material lhal contains mm-ffi.abfe as!resros? s. D E8I Wlll there he demolition rnvotving tJte remmral fillf a load ~g strumrel l1l'lemila? li3liiefly desaite l!rusmess activities: : Md antemras and rauro ca.hill.et Bi'ieffy describe p~ed project: L ~ ~rolect. c':U site rAOD: Tdccomnrunicall.iorns ken siltc) No new haz mat. site over required reporting threshold I dedare tlmfer penalty of pefjiliy !hat to the best of my Emowfedge and belf.ef resJl0lilSes made herein are true and amect. Sheila Cahaliem, Agent fo,-AT&T Services Inc. ~,;;;-~-Aprii 15, 2013 Name of Olma-or-Authorized Agent Signature of Owner err Aulrnlllized Agent Date FOR OFACAL USE ONLY: AREDEPARTMENTOCCUPANCYCLASSIRCATION:,_ _______________________________ _ BY~ DATE: __ .._/ __ ..,,/ __ _ COUNTY-HMO• APCD APCO COUNTY-HMO APCO !deus Materials Business Plan. Other permitting requirements may sli!i apply. County orSan Diego -DEii-Hamrdous Materials Dmsion -·-·-·-·-""" "·--·-·. """""" -----------·-· -·-·-··-------'·--....... , ·-·--· -·------· ·---·------·-------------------------' ------··----' ...... """"" '"'"'""" ""'""'""""'"" """ ---·-"'""' " . ' --" ----"' ---""'" -__________ ,,., X3 Management Senrlce,, Inc:. ProJ3ct I eonstruct.;on l Enfiineer,~ March 5, 2015 City of Carlsbad Building Division 1635 Faraday Ave. Carlsbad, CA 92008 RE: Permit# CB131060 -AT&T Cell Site SD0428 Raceway Site Address: 2714 Loker Avenue West Carlsbad, CA 92008 Dear Building Division, This letter is to inform you that X3 Management Services will no longer be the General Contractor of record for Building Permit CB131060. The applicant, AT&T Mobility has contracted with Aliantel Construction Co. to perform the SOW work for the AT&T Mobility site located at 2714 Loker Avenue. Should you have any questions, please feel free to contact me at {94,9-683-2.345) Thank you, Michael Melcher, Director XJ Management Services, Inc. 2215 Auto Parle Way Escondido, CA 92029 760-658-6455 Corporate Off ice; 2215 Auto Park Way Escondido, CA 92029 Phone 760.658.6455 Fax 760.658.6454 L ___________ _ _ _______________ ,, ________________ _ --·-----------·-----·------------------~~- CB131060 2714 LOKERAVWEST AT&T CELL SITE-REMOVE 8 EXIST! ~~, •wi~~i# "'• ',..·,.•r:~~"-7;,,ft;j,,-., .. · ANTENNAS & INSTALL 12 NEW ANTENNAS. 6 NEW ·---~ .,____ ···~ ~-,,-.. ·-. ____ ..,.,. __ ..,_' ... ',. ________ ._ •. --~ '.L~-.. --'..,..,,/,-______ .,._ ~ ~--_,_-.,. • .......,.,_~..,._,4-' ---~1 c{/is/ !J TD~~ I~ lo~-~/2 LS b I l tv / J/~)J-~ 1 i~ i 1-vie- lfl~/r3 fUOw..,/1:;J ()...µr-- LJ{w{r~ ~~Fe.. S/1/!J ~ j;_Jk ~15"/ le/ d-/;X)/ ,<-/ 61.-P ,r<Vh et\ { eHer 6e,rrT tJ j.21-f) ''f qo ~ ~)l. te-06,e-rt-7 /as..t J,y qo ~ ,e,.x,~b1 ~ to/ ;;>Lf I' y w( fl-L-l-~ I I rJ-fb 1 l oil ic.f CJj1~1Y io(d-41 ,Lf ~__,,()._) vs~~ a(ro(rs· -/IJE;()) ~ COJU77e./]-criJR... SW DISSUED Approved Date BUILDING t::; If. I I { PLANNING I ,J t" ..tJ-rrtL) 4 ?,t(J,"T::(- ENGINEERING t.f/~//.3 FIRE Expedite? y (fit) ~/,1/,3 AFS Checked by; I ,_ ,I ,. HazMat ,"' 1 ._ P\" 11 ' -.. " , •v, ,, APCD I , ·'V Health Forms/Fees Sent Rec'd Encina Fire HazHealthAPCD PE&M School Sewer Stormwater Special Inspection CFO; y N LandUse; Density. lmpArea: FY: Annex: PFF: y N Comments Date Date Date Building Planning 4-/:xdr3 ., Engineering Fire ~liol o Need? f'l...--n~ ~\()\-\:) 1~ I locv By hA--llln Y.. A--S I kJ_ V» ~ ... ,-t:.J - Due? By y N y N . y N y N y N y N y N y N Factor: Date \ b-Bone ODone ODone ODone ODone ODone ,. City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 04-15-2015 Plan Check Revision Permit No:PCR15025 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: PC#: Project Title: Applicant: JUAN TAPIA 2714 LOKER AV WEST CBAD PCR 2090813200 $0.00 Lot#: 0 Construction Type: NEW CB131060 AT&T CELL SITE-REVISE MOUNTING DETAILS FOR ANTENNAS Owner: CBLLLC Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: 38444 SKY CANYON AV MURRIETA CA 92563 951 544-8765 6183 PASEO DEL NORTE #280 CARLSBAD CA 92011 Plan Check Revision Fee Fire Expedited Plan Review Additional Fees Total Fees: $107.50 Inspector: $107.50 $0.00 $0.00 Total Payments To Date: $107.50 Balance Due: FINAL APPROVAL Date: Clearance: ISSUED 03/30/2015 RMA 04/15/2015 04/15/2015 $0.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have oreviouslv been aiven a NOTICE similar to this or as to which the statute of limitations has nreviouslv otherwise exoired. ~~ «~~ ~ CITY OF CARLSBAD PLAN CHECK REVISION APPLICATION B-15 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Plan Check Revision No. -11{!_· CA"""'+-+--</'-"5_._-6_(}5_..:,.,,c___Original Plan Check No. _G..6-----'------'--"13=-.,_l O~(o'"'-'0_~_ Project Address 27/t{ lo l4v Av,Q_ l 0,9--'i)./-Date--=J"---'/-=3i}-"-o_,_/,__,_/ S=------., Ptt:;J (<J'Tl)r0f-S-;6'~ Fax _____ _ Zip 72 g:-(J Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 . Elements revised: ~ Plans D Calculations D Soils D Energy D Other __________ _ 2. 3. Describe revisions in detail List page(s) where each revision is shown )? p Iii s i~I.. Af AT!1 ~I.-\ Je. "'"" .;_ jM,e.)..) I.,_ J. ~ ~ l deJe._;I ...,, IJS,, .. ~ t ) \.. ~ -,~1 vuA it'ti er 1/l-<6111_l ~ ,,_ ;,. ~/ l_,. lA IA-C. k, 6t,ilJ.~t..(. ,./ -V s.J-,1''-'C.:fn ,,. __ < 5. 6. Does this revision, in any way, alter the exterior of the project? D Yes Does this revision add ANY new floor area(s)? 7. Does this revision affect any fire related issues? 8. ls this a complete set? D Yes ~ No D Yes D Yes E/No ref No 4. List revised sheets that replace existinq sheets ,~ 1 vi -7, A-'ls, fl-1. 0'No ~Signature ___________________________ _ 1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: building@carlsbadca.gov www.carlsbadca.gov .. EsGil Corporation In (J?artnersnip witn government for (}Jui{aing Safety DATE: 4/7/2015 a APPLICANT a JURIS. JURISDICTION: City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 13-1060 rev(PCR15025) PROJECT ADDRESS: 2714 Loker Ave. West PROJECT NAME: AT&T 8D0428 Revisions SET: I D D D D D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: I EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Email: Mail Telephone Fax In Person D REMARKS: By: David Yao Enclosures: approved plan EsGil Corporation D GA D EJ D MB D PC 4/2 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 • City-iof-Oarlsbad 13-1060 rev(PCR15025) 4/7/2015 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad rev(PCR15025) PLAN CHECK NO.: 13-1060 PREPARED BY: David Yao BUILDING ADDRESS: 2714 Loker Ave. West BUILDING OCCUPANCY: BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier revisions Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: 0 Complete Review DATE: 4/7/2015 Reg. VALUE Mod. D Structural Only D Repetitive Fee 3 Repeats D Other 0 Hourly EsGil Fee 11Hr. @* :~~~~$_-1_0~0-__ o:o • Based on hourly rate Comments: ($) $100.ool Sheet 1 of 1 macvalue.doc +