Loading...
HomeMy WebLinkAbout2715 CARLSBAD BLVD; ; CB970230; PermitBUILDING PERMIT Permit No: CB970230 10/14/98 16:55 Project No: A9700321 Page 1 of 1 Development No: Job Address: 2715 CARLSBAD BL Suite: Permit Type: COMMERCIAL TENANT IMPROVEMENT Parcel No: 203-143-01-00 Lot#: Valuation: 0 Construction Type: Occupancy Group: Reference*: Status/^ EXPIRED Description: CTI 312 SF ADD SF, STRG/OFFICE Appliedl bljUb/97 : Apr/Issue: Entered By: JM Appl/Ownr : BARBARA MCLEAN PROPERTIES 619 434-6161 2715 CARLSBAD BLVD CARLSBAD, CA 92008 *** Fees Required *** *** Fees Collected & Credits *** Fees: 123.00 Adjustments: .00 Total Credits: .00 Total Fees: 123.00 Total Payments: 123.00 Balance Due: .00 Fee description Units Fee/Unit Ext fee Data Other > 123.00 123.00 PLANCK PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 2075 Las Palmas Dr., Carlsbad CA 92009 (760)438-1161 FOR OFFICE USE O PLAN CHECK NO. EST. VAL. Plan Ck. Deposit Validated Byz Date Address (include Bldg/Suite #)Business Name (at this address) Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. • Total # of units Assessor's Parcel #Existing Use Proposed Use Description of Work OfO ' 2- SQ. FT.of Bedrooms m.JiMiyi' *' ' # of Bathrooms Name Name 4- ST. H. «^4g& P^ 77* Address City State/Zip Telephone #Fax* Name Address B. *tXJNf««CfOIK-CO1^PANrWSWt^ - - ~"~ — - (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001). Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name State License # Address City State/Zip Telephone Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS 1*100] OR LESS) D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shaH subject an employer to criminal penalties and civil fines up to one hundred thouaand dollar* ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor coda, interest and attorney's fees. DATE 5m the Contractor's License Law for the following reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES QlSIO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES Q NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height, EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). WHITE: File YELLOW: Applicant PINK: Finance City of Carlsbad Building Department DATE: 01/02/98 TO: BARBARA MCLEAN PROPERTIES 2715 CARLSBAD BLVD CARLSBAD, CA 92008 PLAN CHECK EXPIRATION PC# CB970230 DATE: 02/06/98 ADDRESS: 2715 CARLSBAD BL You have applied to have your plans checked on the date shown above, and you have not obtained your building permit. The provisions of Section 304(d) of the Uniform Building Code state: "Section 304(d) Expiration of Plan Review Applications for which no permit is issued within one year following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official. In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee." Please check the appropriate box indicating your choice and return this letter to the BUILDING DEPARTMENT. PROJECT ABANDONED. I WILL PICK UP PLANS WITHIN 10 DAYS. PROJECT ABANDONED. PLANS MAY BE DESTROYED. If you have any questions, please contact the Building Department at (619) 438-1161 extension 4331. RAENETTE ABBEY Building Department 2O75 Las Palmas Drive • Carlsbad, California 92OO9 • (619) 438-1161 CXH.G. CONSTRUCTION COMPANY 2427 DUNSTAN STREET OCEANSIDE, CA. PH, (619) 433-7140 FAX, (619) 721-4743 March 28,1997 City of Carlsbad Building Department 2075 Las Palmas Drive Carlsbad, CA. 92009 Atta: Mr. Pat Kelly Re: 2715 Carlsbad Blvd. Plan Check No: 97-230 Mr. Kelly, We thought you should be kept informed as to the progress of the permit process for McLain Properties at the above address. To date Mr. Craig Ruiz, of the City of Carlsbad Housing and Redevelopment Department has assisted us in garnering information on Area 9 of the Carlsbad Village Master Plan and Design Manual. It appears mat this particular project very likely fells into what the Redevelopment Department and the California Coastal Commission want for the area because of its tourist and beach orientation. Our main problem at this point is that real estate brokers are specifically prohibited yet this license is required in order to do beach rentals even though real estate itself ia not being sold through this office. A detailed and complete Redevelopment Guideline and a Village Master Plan and Design Manual is now being requested from the Carlsbad City Housing and Redevelopment Department. Also A detailed guideline with a complete master plan manual from me California Coastal Commission is being requested along with their intend for usage in Area (of the City of Carlsbad. At this point we are extremely optimistic about the results and hope you'll bear with us during mis part of the project. Sincerely, O.H.G. EsGil Corporation 2« Partnership with (government for %ui&(ing Safety DATE: OCTOBER 22, 1998 a APPLICANT JURISDICTION: CARLSBAD [Tro^ ' a FILE PLAN CHECK NO.: 97"23Q SET: T PROJECT ADDRESS: 2715 CARLSBAD BLVD. PROJECT NAME: MCLAIN PROPERTIES ADDITION The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: PLANS DISCARDED AT CITY'S REQUEST. By: KR Enclosures: Esgil Corporation D GA D CM D EJ D PC tmsmtl.** 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619)560-1468 * Fax (619) 560-1576 JURISDICTION: City of Carlsbad S October 8,1998 Please indicate those plans and related documents that can be discarded by Esgil Corporation. Plan Check # / Address Retain the Plans Discard the Plans Return to City 95-1030 V 96-1235 96-1363 97-86 97-88 97-209 97-230 97-1160 97-1177 97-1239 97-1481 97-1637 vx 97-1783 97-1895 v- 97-1913 97-2640 97-3098 97-3172 EsGil Corporation Professional '&fan tyview 'Engineers DATE: 2/13/97 a APPLICANT JURISDICTION: Carlsbad Q PLAN REVIEWER a FILE PLAN CHECK NO.: 97-23O SET: I PROJECT ADDRESS: 2715 Carlsbad Blvd. PROJECT NAME: McLain Properties Addition The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's AXAAAAAAAAA codes. The plans transmitted herewith will substantially comply with the jurisdiction's ********** codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: McLain Properties/Kelley Housley 2715 Carlsbad Boulevard., Carlsbad, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: By: Mike Kratz Enclosures: Esgil Corporation D GA D CM D EJ D PC 2/10/97 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (619)560-1468 + Fax (619) 560-1576 Carlsbad 97-230 2/13/97 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK NO.: 97-230 OCCUPANCY: B TYPE OF CONSTRUCTION: V-n ALLOWABLE FLOOR AREA: 8000 SPRINKLERS?: no REMARKS: 348 sq. ft. new DATE PLANS RECEIVED BY JURISDICTION: 2/6/97 DATE INITIAL PLAN REVIEW COMPLETED: 2/13/97 JURISDICTION: Carlsbad USE: Office ACTUAL AREA: 2643 STORIES: 1 HEIGHT: OCCUPANT LOAD: 24 DATE PLANS RECEIVED BY ESGIL CORPORATION: 2/10/97 PLAN REVIEWER: Mike Kratz FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1994 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. LIST NO. 22, GENERAL COMMERCIAL WITHOUT ENERGY OR POLICY SUPPLEMENTS (1994 UBC ) comforw.dot Carlsbad 97-230 2/13/97 • GENERAL Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (619) 438-1161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. • PLANS 1. This project consists of an addition to a commercial building. Plans must be prepared and stamped and signed by an architect or civil or structural engineer licensed to practice in the State of California. 2. All sheets of the plans and the first sheet of the calculations are required to be signed by the California licensed architect or engineer responsible for the plan preparation. Please include the California license number, seal, date of license expiration and the date the plans are signed. Business and Professions Code. 3. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: * Occupancy Group B 4 Description of Use Office 4 Type of Construction V-n 4 Sprinklers: Yes or No no t Stories 1 4 Height 10ft. 4 Floor Area 2645 4. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1994 UBC. UMC and UPC and 1993 NEC. Carlsbad 97-230 2/13/97 5. Plans appear to be designed under the 1988 UBC. Update the plans to the provisions of the 1994 UBC. and other current codes. 6. On site plan show all interior property lines, easements, development restricted areas, or other buildings. 7. Provide a statement on the site plan stating: "All property lines, easements and buildings, both existing and proposed, are shown on this site plan." 8. Show dimensioned parking layout including any required disabled access spaces. • EXITS 9. Note on the plans: "All exits are to be openable from inside without the use of a key or special knowledge." Section 1004.3. 10. Regardless of occupant load, a floor or landing not more than 1 inch (1/2-inch if disabled access is required) below the threshold is required on each side of an exit door. Section 1004.9. • ROOFS 11. A Class B roof covering is required. Table 15-A. and City of Carlsbad special requirements. 12. Specify roof slope. 13. Provide notes and specifications for roofing materials and application. • FOUNDATION 14. Provide continues footings under all exterior walls and interior bearing walls. Dimension foundations per Table 18-l-D. Floors Footing Supported* Stemwall Width Depth Thickness 1 6" 12" 12" 6" 15. At permit issuance, applicant to sign "Soils Notice Stamp." 16. Show size, type and spacing of connectors of non-bearing wall sills to concrete slab. Carlsbad 97-230 2/13/97 • STRUCTURAL 17. Show wall bracing. Every exterior wood stud wall and main cross partition shall be braced at each end and at least every 25 feet of length. Section 2326.11.3 and Table 23-l-W. 18. Specify plywood grade and panel span rating and nailing for roof sheathing. Table 23-I-S-1. • MISCELLANEOUS 19. Note on the plans that "all weather-exposed surfaces shall have a weather-resistive barrier to protect the interior wall covering and that exterior openings shall be flashed in such a manner as to make them weatherproof. Section 1402. 20. Provide details of restrooms to show compliance with Section 807 regarding floors, walls and showers. 21. In Groups B, F, H, M and S Occupancies, if the number of employees exceeds four, provide separate toilet facilities for men and women. If "the total number of employees will not exceed four", and only one restroom is provided, note the words in quotation above on the floor plan. Section 2902.3. • ENERGY CONSERVATION 22. Provide revised energy calculations based on the current T-24 Energy Regulations. Incorporate requirements into the plans. 23. Provide plans, calculations and worksheets to show compliance with current energy standards. Provide the completed ENV-, LTG-, and MECH- forms showing energy compliance. • ADDITIONAL 24. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Carlsbad 97-23O 2/13/97 25. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Q Yes a No The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Mike Kratz at Esgil Corporation. Thank you. Carlsbad 97-230 2/13/97 DEPARTMENT OF STATE ARCHITECT NON RESIDENTIAL TITLE 24 DISABLED ACCESS REQUIREMENTS The following disabled access items are taken from the 1995 edition of California Building Code, Title 24. Per Section 101.17.11, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities as follows: (1) Any building, structure, facility, complex, or improved area, or portions thereof, which are used by the general public. (2) Any sanitary facilities which are made available for the public, clients, or employees in such accommodations or facilities. (3) Any curb or sidewalk intended for public use that is constructed with private funds. (4) All existing accommodations when alterations, structural repairs or additions are made to such accommodations. NOTE: All Figures and Tables referenced in this checklist are printed in the California Building Code, Title 24. REMODELS. ADDITIONS AND REPAIRS 1. When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected is required to comply with all of the requirements for new buildings, per Section 1134B.2. These requirements apply only to the area of specific alteration, repair or addition and shall include: a) A primary entrance to the building and the primary path of travel to the area in question, and include the following items which serve the area in question: i) Sanitary facilities, ii) Drinking fountains, iii) Public telephones. 2. If an unreasonable hardship finding is granted, priority should be given to those elements that will provide the greatest access, per Section 1134B.2.1 Exception #1. The order of priority shown below should be followed: a) An accessible entrance. b) An accessible route of travel. c) At least one accessible restroom for each sex, d) Accessible telephones. e) Accessible drinking fountains. f) When possible, additional accessible elements such as parking, storage and alarms. Carlsbad 97-230 2/13/97 3. For areas under the control of a single tenant, the obligation to provide access may not be evaded by performing a series of small alterations to the area served by a single path of travel, if those alterations could have been performed as a single undertaking. If an area has been altered without providing an accessible path of travel to that area, and subsequent alterations of that area, or a different area along the same path of travel are undertaken within three (3) years of the original alteration, the total cost of alterations to the areas along that path of travel during the preceding three year period shall be considered in determining unreasonable hardship. SITE PLAN REQUIREMENTS 4. Clearly show that the site development and grading are designed to provide access to all entrances and exterior ground floor exits, as well as access to normal paths of travel, per Section 1127B.1. Where necessary to provide access, shall incorporate pedestrian ramps, curb ramps, stairways and handrails, etc. Show a conforming path of travel for the H.C. parking to the building entrance. • DISABLED ACCESS PARKING SPACES 5. Revise site plan to show that accessible spaces comply with Section 1129B.4.1 asfollows: a) Single spaces shall be 14'0" wide and outlined to provide a 9'0" parking area and a 5'0" loading and unloading area on the passenger side of the vehicle. b) When more than one space is provided, in lieu of providing a 14'0" space for each space, two spaces can be provided within a 23'0" area with a 5"0" loading zone between each 9'0" wide space. c) Each space is to be a minimum of 18'0" in depth. 6. Revise plans to show that at least one in every 8 accessible spaces are served by an access aisle ^96" in width and designated as VAN ACCESSIBLE, per Section 1129B.4.2. All such spaces may be grouped on one level of a parking structure. 7. Show or note that the maximum slope of the parking surface at the accessible space, in any direction, is <%" per ft (2.083%), per Section 1129B.4.4. The maximum slope at the passenger loading zone is to be Carlsbad 97-230 2/13/97 8. Show or note on the plans that the accessible parking spaces are to be identified by a reflectorized sign, permanently posted immediately adjacent to and visible from each space, consisting of: a) A profile view of a wheelchair with occupant in white on dark blue background. b) The sign shall >70 in2 in area. c) When in the path of travel, they shall be posted ^80" from the bottom of the sign to parking space finished grade. d) Signs may also be centered on the wall of the interior end of the parking space >36" from the parking space finished grade, ground or sidewalk. e) Spaces complying with Section 1129B.4.2 shall have an additional sign 'Van-Accessible" mounted below the symbol of accessibility per Section 1129B.5. f) In addition, each accessible space is required to be marked with the international symbol of accessibility. 9. Show, or note, that an additional sign shall also be posted in a conspicuous place at each entrance to off street parking facilities, or immediately adjacent to and visible from each stall or space. The sign shall be >17" x 22" with lettering not <1" in height. Per Section 1129B.5 required wording is as follows. "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at or by telephoning ." • DOORS 10. Show, or note, that there is a level floor or landing on each side of all doors. The floor or landing is to be £%" lower than the doorway threshold, per Section 1004.9.1 a. 11. Show or note that all hand-activated door opening hardware meets the following requirements, per Section 1004.3.1: a) Is to be centered >30" but £44" above floor. b) Latching, or locking, doors in a path of travel are operated with a single effort by: i) Lever type hardware. ii) Panic bars. iii) Push-pull activating bars. iv) Or other hardware designed to provide passage without the requirement to grasp the hardware. Carlsbad 97-230 2/13/97 • SANITARY FACILITIES 12. Where separate nonaccessible facilities are provided for each sex, separate accessible facilities are required to be provided for each sex as well. Where nonaccessible unisex facilities are provided, accessible unisex facilities are required to be provided, per Section 1115B.2. 13. Note that the doorways leading to sanitary facilities shall be identified, per Section 1115B.5, as follows: a) An equilateral triangle %" thick with edges 12" long and a vortex pointing upward at men's rest rooms. b) A circle %" thick, 12" in diameter at women's rest rooms. c) A 12" diameter circle with a triangle superimposed on the circle and within the 12" diameter at unisex rest rooms. d) The required symbols shall be centered on the door at a height of 60". e) Braille signage shall also be located on the wall adjacent to the latch outside of the doorways leading to the sanitary facilities, per Section 1117B.5.9. • RESTROOM FIXTURES AND ACCESSORIES 14. Show that accessible lavatories comply with the following, per Sections 1115B.9.1 and California Plumbing Code: a) i) >29" high x 30" wide x 8" deep at the top. ii) £9" high x 30" wide and 17" deep at the bottom. iii) The counter top is ^34" maximum above the floor. b) Hot water pipes and drain lines are insulated. c) The faucet controls, and operating mechanism are: i) The type which does not require tight grasping, pinching or twisting of the wrist. ii) Has an operating force of d) If self-closing valves are used, they shall remain open for >10 seconds. 15. Revise plans to show that grab bars comply with the following, per Section 1115B.8: a) Grab bars shall be located on each side or one side and the back of the water closet stall or compartment. Carlsbad 97-230 2/13/97 b) They shall be securely attached 33" above the floor, and parallel. NOTE: Where a tank-type toilet is used which obstructs placement at 33", the grab bar may be installed as high as 36". c) Grab bars at the side shall be located: i) 15" to 16%" (±1") from the center line of the water closet stool, ii) Be s42" long with the front end positioned 24" in front of the stool, iii) Total length of bars at the back shall be >36". d) The diameter, or width, of the grab bar gripping surface is >1%" but <1%", or the shape shall provide an equivalent gripping surface. e) If mounted adjacent to a wall, the space between the wall and the grab bar shall be 1%". f) Be designed to support 250#. Carlsbad 97-230 2/13/97 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Mike Kratz BUILDING ADDRESS: 2715 Carlsbad Blvd. PLAN CHECK NO.: 97-230 DATE: 2/13/97 BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: V-n BUILDING PORTION Office Air Conditioning Fire Sprinklers TOTAL VALUE BUILDING AREA (ft-2) 348 VALUATION MULTIPLIER $55.00 VALUE ($) $19,140.00 $19,140.00 ^1991 UBC Building Permit Fee D Bldg. Permit Fee by ordinance: $ 207.00 ^1991 UBC Plan Check Fee D Plan Check Fee by ordinance: $ 134.55 Type of Review: ^ Complete Review Q Structural Only CD Hourly O Repetitive Fee Applicable O Other: Esgil Plan Review Fee: $ 107.64 Comments: Sheet 1 of 1 macvalue.doc 5196 City of Carlsbad Engineering Department DATE:3/3/1? BUILDING ADDRESS: BUILDING PLANCHECK CHECKLIST PLANCHECK NO.: CB BftfJi. PROJECT DESCRIPTION: ASSESSOR'S PARCEL NUMBER:~ O)EST. VALUE: )"7 ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. A Right-of-Way permit is required prior to construction of the following improvements: DENIAL Please see the attached report of deficiencies marked with . Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: By: Date: Date: By: FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: Date: ATTACHMENTS Dedication Application Dedication Checklist Improvement Application Improvement Checklist Future Improvement Agreement Grading Permit Application Grading Submittal Checklist Right-of-Way Permit Application Right-of-Way Permit Submittal Checklist and information Sheet Sewer Fee Information Sheet ENGINEERING DEPT. CONTACT PERSON Name: David Rick City of Carlsbad Address: 2075 Las Palmas Dr., Carlsbad, CA 92009 Phone: (619)438-1161, ext. 4324 A-4 CA 92OO9-1576 - (619) 438-1161 - FAX (619) BUILDING PLANCHECK CHECKLIST iSTV rj Q Q Q SITE PLAN 1 . Provide a fully dimensioned site plan drawn to scale. Show: CXDX <JE. Property Lines Easements F. Right-of-Way Width & Adjacent Streets G. Driveway widths North Arrow Existing & Proposed Structures Existing Street Improvements Show on site plan: rainage Patterns Existing & Proposed Slopes C. Existing Topography 3. Include note: "Surface water to be directed away from the building foundation at a 2% gradient for no less than 5' or 2/3 the distance to the property line (whichever is less)." [Perl 985 UBC 2907(d)5] On graded sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus two percent." [Per 1990 UBC 2907(d)5] rj 4. Include on title sheet: A. Site address B. Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION Page 1 of 4 H:\WORD\DOCS\CHKLSTOuidlng Plancheck CUst BP0001 Form ORdoe BUILDING PLANCHECK CHECKLIST DISCRETIONARY APPROVAL COMPLIANCE 5. Project does not comply with the following Engineering Conditions of approval for Project No.. Q Q Q 6. All conditions are in compliance. Date: DEDICATION REQUIREMENTS Q Q a 7. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ , pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 !4" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS Q 8a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ , pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: Date: Page 2 of 4 G:»LIBRARYl£NQ\WORDT)OCS\CHKLS'hBu*]l(ig Ptarwfleck CUst BP0001 FormDfl.doc BUILDING PLANCHECK CHECKLIST A st/ ond/ ord/ Q Q Q 8b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $ so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: tr a Q Q Q 8c. Enclosed please find your Future Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Future Improvement Agreement completed by: Date: Q Q 8d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the Citv Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. Q Q Q 9a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). Q Q Q 9b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: 9c. No Grading Permit required. Page 3 of 4 G:\LIBFURY\ENGWORD\DOCS\CHKLSTOulHing Planchecfc CWM BP0001 Form DR.doc BUILDING PLANCHECK CHECKLIST MISCELLANEOUS PERMITS A sty/ ond/ ord^" Q Q 10. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tieing into public storm drain, sewer and water utilities. Right-of-Way permit required for: Q Q Q 11. A SEWER PERMIT is required concurrent with the building permit issuance. The fee is noted in the fees section on the following page. Q Q 12. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Permit. Industrial Waste permit accepted by: Date: Q Q 13. NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. Q Q 14. j Required fees are attached Q No fees required Q Q Q 15. Additional Comments: Page 4 of 4 Q:M-IBRARY«ENG\WOROM>OCSVCHKLSPSuMina Ptancheck CUM BP0001 Fwm OR.doc ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D Estimate based on unconfirmed information from applicant. D Calculation based on building plancheck plan submittal. 6M .Address:Bldg. Permit No.£3 *??- 23 ° Prepared by: D- rv Date; 3/3,/<?'?Checked by:Date: EDU CALCULATIONS: List types and square footages for all uses. Types of Use: &&fj <^~ Sq. Ft./Units: 3^- EDU's: APT CALCULATIONS: List types and square footages for all uses. Types of Use: Qm£&-^ Sq. Ft./Units: 2.0 - - 7.0* ADT's: FEES REQUIRED: ^: fj YESPUBLIC FACILITIES FEE REQUIRED: fj YES D NO (See Building Department for amount) WITHIN CFD: D YES {no bridge & thoroughfare fee, reduced Traffic Impact Fee) gTNO / \3T2. . PARK-IN-LIEU FEE FEE/UNIT: PARK AREA: X NO. UNITS:=$**s 2. TRAFFIC IMPACT FEE ADT's/UNITS:"7 . BRIDGE AND THOROUGHFARE FEE ADT's/UNITS: X FEE/ADT: X FEE/ADT: = $ = $. k FACILITIES MANAGEMENT FEE UNIT/SQ.FT.: 1ST 5. SEWER FEE PERMIT No. EDU's: CID BENEFIT AREA: EDU's: ZONE: _ X FEE/SQ.FT./UNIT:^ X FEE/EDU: DRAINAGE BASIN: 6. DRAINAGE FEES PLDA ACRES: ___ X FEE/EDU: HIGH /LOW X FEE/AC: 7. SEWER LATERAL ($2,500) = *. = $. = $. = $ TOTAL OF ABOVE FEES*: $£00 *NOTE: This calculation sheet is NOT a complete list of all fees which may be due. Dedications and Improvements may also be required with Building Permits. P:\DOCS\MISFORMS\BPOQ02.FRM REV 01/22/97 U. D D D D D D PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB Address 21 15 Phone (619) 43B--MOV APN: Type of Project and Use: ADDITION) oF 2 ROOMS Fog A Zone: Vf?» Facilities Management Zone: I OP ftf property in. cornptm SPECIAL TAX CALCULATION WORKSHEET provioed Dv Buitomg CFD (in^ut) CirctB Legend Item Complete hem Incomplete - Needs your action Environmental Review Required: YES DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Discretionary Action Required: APPROVAL/RESO. NO. PROJECT NO. YES NO DATE ___ TYPE OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval O Q Q Coastal Zone Assessment/Compliance NOProject site located in Coastal Zone? YES If NO, proceed with checklist; if YES, proceed below. Determine status (Exempt or Coastal Permit Required): _ tf Exempt, proceed with checklist; if Coastal Permit required, hold building permit until Coastal Permit issued. Coastal Permit Determination Form already completed? YES If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: NO Foliow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. D D D Inclusionary Housing Fee required: YES NO ' \ (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Site Plan: HI D D 1- Provide a fully dimensional site plan drawn to scale. Show: North arrow property lines, easements, existing end proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines. d CD EH 2. Provide legal description of property and assessor's parcel number. Zoning: ODD !• Setbacks: ODD D D D D D D ODD Front: Required Int. Side: Required Street Side: Required Rear: Required 2. Lot Coverage: Required 3. Height: Required 4. Parking: Spaces Required Guest Spaces Required Additional Comments Shown Shown Shown Shown Shown Shown Shown Shown OK TO ISSUC AND CNTERED APPROVAL INTO C&MPPTEff DATE d> This permi-f Can'4- be approved . I he land U5<= fe> no-f under +n* n«=uo V.'l/^e MaS^< Plan H- D=SlQn , boh.ch ma*^ +^ land use non-confer C,n be City of Carlsbad Housing & Redevelopment Department February 19, 1997 KELLEY HOUSLEY 2715 CARLSBAD BLVD. CARLSBAD, CA. 92008 RE: BUILDING PERMIT APPLICATION - PLAN CHECK NO. 970230 Dear Ms. Housley: A copy of your plans for expansion of the Barbara McLain Properties Office located at 2715 Carlsbad Boulevard was forwarded to the Housing and Redevelopment Office for review. Unfortunately, the Carlsbad Village Master Plan and Design Manual does not allow for the expansion desired for the subject property. Therefore, you will not be able to obtain approval of the requested building permit. The reasons for denial are explained in more detail below. The new Village Master Plan and Design Manual, which became effective on September 12, 1996 for all properties located within the Coastal Zone, does not allow for general office uses in Land Use District 9 of the Village Redevelopment Area. Your property is located in Land Use District 9, which is designated primarily as a tourist support area. This land use finding means that your office is considered a "non-conforming land use". You will be permitted to continue the office use for as long as you choose to do so. However, the Redevelopment Agency will not be allowed to approve any expansion of the existing building. Enclosed please find copies of the current land use plan for the Village Redevelopment Area and the regulations related to "non-conforming" land uses. I hope you find this information to be helpful in any future decisions you may need to make in regard to the office operations for Barbara McLain Properties. If you have questions or comments regarding this correspondence, please contact my office at 434-2935. Sincerely, DEBBIE FOUNTAIN Senior Management Analyst Enclosures 2965 Roosevelt St., Ste. B • Cartsbad, CA 92008-2389 * (619) 434-2810/2811 • FAX (619) 720-2037 ifiii X o &u - 01