Loading...
HomeMy WebLinkAbout2715 Cypress Hill Rd; ; CBR2017-0877; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Print Date: 05/03/2017 Residential Permit Permit No: CBR2017-0877 www.carlsbadca.gov Job Address:2715 Cypress Hill Rd Permit Type:BLDG-Residential Work Class:Cogen Status:Closed -Finaled Parcel No:1563321700 Lot #:Applied:04/25/2017 Valuation:$4,800.00 Reference #:Issued:04/25/2017 Occupancy Group:Construction Type:Finaled: Dwelling Units:Bathrooms:Inspector:MColl Bedrooms:Orig. Plan Check 4: Plan Check 4: Project Title: Description:AUSTAN: SOLAR, FLUSH MOUNTED TO ROOF, 12 MOD, NO RMA, NO UPGRADE Owner:Contractor: TRUST AUSTIN DEBORAH L TRUST 11-17-06 STELLAR SOLAR 2715 Cypress Hill Rd CARLSBAD, CA 92008 6965 El Camino Real 760-822-5880 Carlsbad, CA 92011 760-529-7267 BUILDING PERMIT FEE $2000+$70.61 BUILDING PLAN CHECK FEE (BLDG)$49.43 5E11473 BUILDING STANDARDS FEE $1.00 STRONG MOTION-RESIDENTIAL $0.62 Total Fees:$121.66 Total Payments To Date:$121.66 Balance Due:$0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction."You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project.NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE:0 PLANNING ElENGINEERING 1:3BUILDING 0 FIRE 0 HEALTH El HAZMAT/APCD Building Permit Application Plan Check No.CAKQ...c)1 F9- X 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value 1 ro6CITYOFPh: 760-602-2719 Fax: 760-602-8558 Plan Ck. Deposit CARLSBAD email: building@carlsbadca.gov www.carlsbadca.gov Date 7-0412512017 JOB ADDRESS et.SUITEVSPACEVUNITS APN 2715 CYPRESS HILL RD 156 -332 -17 -00 CT/PROJECT #LOT #PHASE ## OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE OCC. GROUP DESCRIPTION OF WORK:Include Square Feet of Affected Area(s) NEW PV CONSISTING OF (12) SUNPOWER SPR-X22.360-C-AC MODULES 4.32 KWDC -(SYSTEM FLUSH MOUNTED TO ROOF) NO SDG&E RMA ADAPTER OR SERVICE UPGRADE EXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF)' DECKS (SF)FIREPLACE AIR CONDITIONING FIRE SPRINKLERS YESD.NOD YESONO YES NOE APPLICANT NAME (Primary Contact)ANTHONY BAZAN APPLICANT NAME (Secondary Contact) ADDRESS ADDRESS 5451 AVNIDA ENCINAS CITY STATE ZIP CITY STATE ZIP CARLSBAD CA 92008 PHONE FAX PHONE FAX 760-712-9482 EMAIL EMAIL ANTHONYBRSTELLARSOLAR.NER PROPERTY OWNER NAME CONTRACTOR BUS. NAME • DEBORAH AUSTAN STELLAR SOLAR ADDRESS ADDRESS 2715 CYPRESS HILL RD 5154 AVENIDA ENCINAS CITY STATE ZIP CITY STATE ZIP CARLSBAD CA 92008 CARLSBAD CA 92008 PHONE FAX PHONE FAX 760-822-5880 I 760 529 7267 EMAIL EMAIL ANTHONYB@STELLARSOLAR.NET ARCH/DESIGNER NAME & ADDRESS STATE LIC. #STATE LIC.#CLASS CITY BUS. LIC.# 749095 C10 1227344 (Sec.7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires theapplicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). S $.A 7.10im ..•:J Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self•insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation,as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co.CYPRESS INSURABNCE OMPANY Policy No.TMWC707290 Expiration Date 8131117 This section need not be completed if the permit is for one hundred dollars ($100) or less. ElCertificate of Exemption:I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California.WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (5100,000), in addition to the cost of compensation, dame •ed for in Section 3706 of the Labor code, interest and attorney's fees. ../e CONTRACTOR SIGNATURE El AGENT DATE e31--t f4.••" ••-•••-.••'•• I hereby affirm that I am exempt from Contractor's license Law fo °flowing reason: I,as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale.If,however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I,as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of properly who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). ElI am exempt under Section Business and Professions Code for this reason: 1.I personally plan to provide the major labor and materials for construction of the proposed property improvement.Efres ON° 2.I (have / have not) signed an application fora building permit for the proposed work. 3.I have contracted with the following person (firm) to provide the proposed construction (include name address /phone/contractors' license number): 4.1 plan to provide portions of the work, butI have hired the following person to coordinate, supervise and provide the major work (include name I address / phone / contractors' license number): 5.I will provide some of the work, but) have contracted (hired) the following persons to provide the work indicated (include name /address /phone / type of work): AtcPROPERTYOWNER SIGNATURE-"..,,AGENT DATE oCk .•.,..,- OMP1ETE THIS 'SECTION FOR NON -RESIDENTIAL -8U/LDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?0 Yes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?0 Yes Cl No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?Cl Yes Cl No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. "inCa7-•.;;;V:.)7•VZIArlfrr•ATIWIPRit.AlltirVIITrrAtt.••ki.40t.A14.11KfiVitt --AO s 13.4,0aWAIMEMff dg% I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lenders Name Lender's Address ••. il4 •' ri.131.4C dlk T CEP TIFICAT,10N I certify that !have mad the application and state thatthe above InformationIsconect and thatthe information on the plans is accurate. I agree to comply with all Ckordinances and State laws relating tobulking constriction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes.I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID MY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over SO' deep and demotion or construction of structures over 3 stories inheight. EXPIRATION: Every permit issued by the Building Official under the pmvisionsofthis Code shall expire by limitation and become null and void N the building or work authorized by such permit is not commenced within 180 days from the date of -'••:•'. or work authorized by such permit is suspended or abandoned at any lime after the workis commencedfora period of 180 days (Section 106.4.4 Uniform Building Code). 1111000...eAPPLICANT'S SIGNATURE••DATE 631.4 c" • INSPECTION HISTORY REPORT (CBR2017-0877)• •.•• Permit Type:BLDG-Residential Application Date:04/25/2017 Owner:TRUST AUSTIN DEBORAH L TRUST 11 -17-06 Work Class.Cogen Issue Date:04/25/2017 Subdivision:CARLSBAD TCT#77-02 UNIT#03 Status:Closed -Finaled Expiration Date:10/30/2017 Address:2715 Cypress Hill Rd Carlsbad, CA 92008-6849 IVR Number:3343 Scheduled Actual Date Start Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection Complete 05/0312017 05103/2017 BLDG-35 Solar 021973-2017 Passed Michael Collins Complete Panel Checklist item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Final 022168.2017 Passed Michael Collins Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Release emailed to SDGE.Yes BLDG-Electrical Final Yes ••_..ng 011117 Page i of