Loading...
HomeMy WebLinkAbout2716 MORNING GLORY LN; ; CB044125; Permit01-03-2005 Job Address Permit Type Parcel No Valuation Occupancy Group # Dwelling Units Bedrooms Project Title City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No CB044125 Building Inspection Request Line (760) 602-2725 2716 MORNING GLORY LN CBAD RESDNTL Sub Type 1561203300 Lot# 563,800 00 Construction Type Reference # 0 Structure Type 0 Bathrooms DECARLO RES 90SF 1ST STORY RAD RAD 0 NEW 490 SF 2ND~ST0fl-Y-RAD Status Applied Entered By Plan Approved Issued Inspect Area Orig PC# Plan Check* ISSUED 11/10/2004 SB 01/03/2005 01/03/2005 Applicant TR JACKSON CONSTRUCTION & RENOVATION 9149XGLEARLAKEWY LAK ES I 619-442-6125 Owner DECARLO FAMILY TRUST 06-14-94 P O BOX 2335 VISTA CA 92085 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $407 96 Meter Size SO 00 Add'l Reel Water Con Fee $26517 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $6 38 PFF SO 00 PFF(CFDFundl SO 00 License Tax $000 License Tax (CFD Fund) $0 00 Traffic Impact Fee $0 00 Traffic Impact (CFD Fund) $0 00 Sidewalk Fee SO 00 PLUMBING TOTAL SO 00 ELECTRICAL TOTAL SO 00 MECHANICAL TOTAL SO 00 Housing Impact Fee SO 00 Housing InLieu Fee Housing Credit Fee SO 00 Master Drainage Fee SO 00 Sewer Fee Additional Fees TOTAL PERMIT FEES SO 00 SO 00 SO 00 SO 00 SO 00 SO 00 SO 00 $000 $000 SO 00 $000 $5500 $2000 S3050 $000 $000 SO 00 $000 $000 $000 S785 01 Total Fees $785 01 Total Payments To Date $26517 Balance Due $51984 BUHDING PCAN5S V__ IN STORAGE ATTACHED QjA/3'05 000 2 OJ 02 CGH Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of foes, dedications, reservations, or other exactions hereafter collectively referred to as fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a). and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that proi edure will bar any subsequent legal action to attack, review, set aside, void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired 319-84 PERMIT APPLICATION ILDICITY OF CARL'SeftD BUILDING DEPART 1635 Faraday Ave , Carlsbad, CA 92008 : PROJECT INFORMATION(arm FOR OFFICE USE ONLY PLAN CHECK NO EST VAL ^^ Plan Ck Deposit Validated Date , / 7 "~ 5227 11/10/04 OOP? 01i A^" tr^tf "^»1255717Address (include Bldg/Suite #)Business Name (at this address)f-a Legal Descripi l»o(0 Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor's Parcel , , • - . _i nddrhm Existiqa Use Description of Work erent from ap SQ FT -lh. #of Stories # of Bedrooms # of Bathrooms Address City Agent for Contractor '^0 Owner1 HI-Agent for Owner.*4 _ . f ft, xiLEl . ^rrv *~ ^"^ *^ /"y\ State/Zip "Telephone #Fax # ontractor '?-(Mhc Name Address City State/Zip Telephone # • vv" Address City State/Zip TelephoneName 5~ CONTRACTOR , (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code! or that he is exempt therefrom, and the basis for the alleged exfmQjjon^-j&rjy VWlajjaojjf Sectign,7Q31_5_|b^any applicant for a Rejmit.subjectSxthe applicant to a civjjjienalt^oinot/qor? thaji fiva h,u^drejf| g'qjjars |$500J) State License # \Q^ ifl r ' ftl Addrefesv^y License Class 8 ^ City State/Zip f^r\iCity Business License # l\ r? Telephone # ?ue£> Designer Name State License # Address City State/Zip Telephone 6^: i! WORKERS' COMPENSATION ' "~~^W' ' :"W" '^*;I ......... -^f^a-^ •••••••• \ Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations l~l I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued BO I have and will maintain workers' compensation as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My worker's compensation insurance carrier and policy number are \C\ r\\ -~* IV i/j 'ObInsurance Company Policy No Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS) l~l CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000fl,_in a&Uion iwthe cost of compensation damages as provided for in Section 3706 of the Labor codejnterest and attorney s fees SIGNATURED _ /^ ' I/JW Uj __ DATE / 7 ' " odejnt $7 I hereby affirm that I am exempt from'ftie Contractor's License Law for the following reason l~l I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) l~l I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) l~l I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement l~) YES l~lNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE Tp^^ • •'--^•••^- •••'"IV: / • ". y:*-J5' :'""" "'^-'":^ "~"r'^" ! f -lilyisS'.. Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES [~] NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? f~l YES O NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? d YES O NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT ^..—nSONsrj^^ .•:,...,L^tf^f •.; ..,._„ ., ,. .:i.^yi,, *L.: ;..i..:.-K. .,.„.. . I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code) LENDER'S NAME LENDER S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days foJnvthe date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced fd^p^rioo/qf^lgo^j^j^ection 106 4 4 Uniform Building Code) APPLICANT'S SIGNATURE DATE 'HITE File YELLOW Applicant PINK Finance City of Carlsbad Bldg Inspection Request For 10/19/2005 Permit* CB044125 Title DECARLO RES 90SF 1ST STORY RAD Description 490 SF 2ND STORY RAD Inspector Assignment RB 2716 MORNING GLORY LN Lot 0 Type RESDNTL Sub Type RAD Job Address Suite Location APPLICANT TR JACKSON CONSTRUCTION & RENOVATION Owner DECARLO LUDOVICO L JR Remarks Phone 6192467562 Inspector Total Time Requested By MITCHELL Entered By JANEAN CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act .Comment Associated PCRs/CVs PCR05070 ISSUED DECARLO RES REV TO RAFTER, ADD FAU PLATFOKM Inspection History Date 08/30/2005 05/27/2005 05/27/2005 05/27/2005 05/16/2005 05/13/2005 05/10/2005 04/14/2005 04/06/2005 04/06/2005 04/06/2005 04/06/2005 03/25/2005 03/23/2005 03/23/2005 03/23/2005 Description 89 17 18 23 16 16 84 14 14 24 34 44 33 13 24 34 Final Combo Interior Lath/Drywall Exterior Lath/Drywall Gas/Test/Repairs Insulation Insulation Rough Combo Frame/Steel/Bolting/Welding Frame/Steel/Bolting/Weldmg Rough/Topout Rough Electric Rough/Ducts/Dampers Service Change/Upgrade Shear Panels/HD's Rough/Topout Rough Electric Act CO AP AP AP AP CO AP CA CO AP CO CO PA PA AP AP Insp RB RB RB RB JM JM RB RB RB RB RB RB PY RB RB RB Comments SEE NOTICE OK TO DRYWALL - NO RECORD CARD NOT COMPLETE RECALL WHEN ALL COMBO CORRECTIONS ARE DONE 3 PAGE LIST TPPB PRELIM @ SHR WALLS OK TO SHR BUT NOT MAIN PANEL City of Carlsbad Bldg Inspection Request For 08/30/2005 Permit* CB044125 Title DECARLO RES 90SF 1ST STORY RAD Description 490 SF 2ND STORY RAD Inspector Assignment RB Type RESDNTL Sub Type RAD Job Address 2716 MORNING GLORY LN Suite Lot 0 Location APPLICANT TR JACKSON CONSTRUCTION & RENOVATION Owner DECARLO LUDOVICO L JR Remarks wants to meet inspector ; Phone 6192467562 Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By MITCHEL Entered By CHRISTINE Act Comment Date 05/27/2005 05/27/2005 05/27/2005 05/16/2005 05/13/2005 05/10/2005 04/14/2005 04/06/2005 04/06/2005 04/06/2005 04/06/2005 03/25/2005 03/23/2005 03/23/2005 03/23/2005 03/18/2005 Associated PCRs/CVs PCR05070 ISSUED DECARLO RES REV TO RAFTER, ADD FAU PLATFORM Inspection History Description Act Insp Comments 17 Interior Lath/Drywall AP 18 Exterior Lath/Drywall AP 23 Gas/Test/Repairs AP 16 Insulation AP 16 Insulation CO 84 Rough Combo AP 14 Frame/Steel/Bolting/Welding CA 14 Frame/Steel/Bolting/Welding CO 24 Rough/Topout AP 34 Rough Electric CO 44 Rough/Ducts/Dampers CO 33 Service Change/Upgrade PA 13 Shear Panels/HD's PA 24 Rough/Topout AP 34 Rough Electric AP 13 Shear Panels/HD's PA Insp RB RB RB JM JM RB RB RB RB RB RB PY RB RB RB RB OK TO DRYWALL - NO RECORD CARD NOT COMPLETE RECALL WHEN ALL COMBO CORRECTIONS ARE DONE 3 PAGE LIST TPPB PRELIM @ SHR WALLS OK TO SHR BUT NOT MAIN PANEL OK TO WRAP - NEED PRELIM FOR INTERIOR SHR @ EXTERIOR CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE TIME LOCATION PERMIT NO (760) 602-2700 1635 FARADAY AVENUE . c CH *C r,Y /T^t / FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? FOR FURTHER INFORMATION, CONTACT X /g YES PHONE TOR CODE ENFORCEMENT OFFICER ® City of Carlsbad Bldg Inspection Request For 05/10/2005 Permit* CB044125 Title DECARLO RES 90SF 1ST STORY RAD Description 490 SF 2ND STORY RAD Sub Type RAD Inspector Assignment RB 2716 MORNING GLORY LN Lot 0 Type RESDNTL Job Address Suite Location APPLICANT TR JACKSON CONSTRUCTION & RENOVATION Owner DECARLO LUDOVICO L JR Remarks Phone 6192469828 Inspector Total Time Requested By TOM Entered By CHRISTINE CD Description Act Comment 14 Frame/Steel/Boltmg/Weldmg 24 Rough/Topout 34 Rough Electric 44 Rough/Ducts/Dampers Associated PCRs/CVs PCR05070 ISSUED DECARLO RES REV Inspection History Date 04/14/2005 04/06/2005 04/06/2005 04/06/2005 04/06/2005 03/25/2005 03/23/2005 03/23/2005 03/23/2005 03/18/2005 03/15/2005 03/15/2005 03/15/2005 03/04/2005 03/04/2005 Description 14 14 24 34 44 33 13 24 34 13 13 14 15 13 15 Frame/Steel/Bolting/Welding Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Rough/Ducts/Dampers Service Change/Upgrade Shear Panels/HD's Rough/Topout Rough Electric Shear Panels/HD's Shear Panels/HD's Frame/Steel/Bolting/Welding Roof/Reroof Shear Panels/HD's Roof/Reroof Act CA CO AP. CO CO PA PA AP AP PA CO we PA CO CO TO RAFTER. ADO FAU PLATFORM Insp RB RB RB RB RB PY RB RB RB RB RB RB RB RB RB Comments RECALL WHEN ALL COMBO CORRECTIONS ARE DONE 3 PAGE LIST TPPB PRELIM @ SHR WALLS - OK TO SHR BUT NOT MAIN PANEL OK TO WRAP - NEED PRELIM FOR INTERIOR SHR @ EXTERIOR WALLS 4TH TIME - SEE NOTICE. ATTACHED OK TO ROOF SEE NOTICE - TRUSSES OK 3RD TIME - PAY REINSP FEE - SEE NOTICE SEE NOTICE PAY RE-INSPEC FEE NOTICE CITY OF CARLSBAD (760) 602-2700 BUILDING DEPARTMENT 1635 FARADAY AVE NUE DATE TIME LOCATION PERMIT NO FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? L_ YES FOR FURTHER INFORMATION, CONTACT PHONE CODE ENFORCEMENT OFFICER ?; City of Carlsbad Bldg Inspection Request For 04/06/2005 Permit* CB044125 Title DECARLO RES 90SF 1ST STORY RAD Description 490 SF 2ND STORY RAD Inspector Assignment RB Sub Type RAD 2716 MORNING GLORY LN Lot 0 Type RESDNTL Job Address Suite Location APPLICANT TR JACKSON CONSTRUCTION & RENOVATION Owner DECARLO LUDOVICO L JR Remarks Phone 6192469828 Inspector Total Time CD Description Act Comment 14 Frame/Steel/Boltmg/Weldmg ^& 3 24 Rough/Topout 34 Rough Electric 44 Rough/Ducts/Dampers Requested By TOM Entered By CHRISTINE 11" Associated PCRs/CVs Inspection History Date Description Act Insp 03/25/2005 33 Service Change/Upgrade PA PY 03/23/2005 13 Shear Panels/HD's PA RB 03/23/2005 24 Rough/Topout AP RB 03/23/2005 34 Rough Electric AP RB 03/18/2005 13 Shear Panels/HD's PA RB 03/15/2005 13 Shear Panels/HD's CO RB 03/15/2005 14 Frame/Steel/Boltmg/Weldmg WC RB 03/15/2005 15 Roof/Reroof PA RB 03/04/2005 13 Shear Panels/HD's CO RB 03/04/2005 15 Roof/Reroof CO RB 03/03/2005 14 Frame/Steel/Boltmg/Welding WC RB 03/03/2005 15 Roof/Reroof NR RB 02/23/2005 13 Shear Panels/HD's NR RB 02/23/2005 14 Frame/Steel/Bolting/Weldmg WC RB 02/23/2005 15 Roof/Reroof NR RB Comments TPPB PRELIM @ SHR WALLS OK TO SHR BUT NOT MAIN PANEL OK TO WRAP - NEED PRELIM FOR INTERIOR SHR @ EXTERIOR WALLS 4TH TIME - SEE NOTICE ATTACHED OK TO ROOF SEE NOTICE - TRUSSES OK 3RD TIME-PAY REINSP FEE - SEE NOTICE SEE NOTICE PAY RE-INSPEC FEE NO PLANS OR LADDER RESUBMIT CHANGES TO CITY (1106-E4) CITY OF CARLSBAD BUILDING DEPARTMENT DATE 'V&4. NOTICE (760) 602-2700 1635 F:ARADAY AVENUE TIME. LOCATION_ PERMIT NO c »w t •*~f\r-r / * r Lr S" f>G£s, / •?. <T C7/ p , ,-, , sff &- <L / s7# 0es //< * // ^/^y FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? FOR FURTHER INFORMATION, CONTACT YES PHONE BUILDING INSPECTOR CODE ENFORCEMENT OFFICER ® CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE -LOCATION PERMIT NO (760) 602-2700 1635 FARADAY AVENUE TIME ^ 3-S. ^> FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? _ YES FOR FURTHER INFORMATION, CONTACT PHONE BUILDING INSPECTOR CODE ENFORCEMENT OFFICER ® CITY OF CARLSBAD BUILDING DEPARTMENT DATE ,.,', ,->,a /V NOTICE ~ fa " & 9 LOCATION PERMIT NO (760) 602-2700 1635 FARADAY AVENUE TIME. /' ftrf^fe^ 3- y & €<*</,« ^/^J^/xf ^/^, ^ ? [— j FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? I J FOR FURTHER INFORMATION, CONTACT ____ YES PHONE ILDING INSPECTOR CODE ENFORCEMENT OFFICER car City of Carlsbad Bldg Inspection Request For 03/15/2005 Permit* CB044125 Title DECARLO RES 90SF 1ST STORY RAD Description 490 SF 2ND STORY RAD Inspector Assignment RB Sub Type RAD 2716 MORNING GLORY LN Lot 0 Type RESDNTL Job Address Suite Location OWNER DECARLO FAMILY TRUST 06-14-94 Owner DECARLO LUDOVICO L JR Remarks Phone 6192469828 Inspector Total Time Requested By TOM Entered By CHRISTINE CD Description Act Comment 14 Frame/Steel/Bolting/Welding 15 Roof/Reroof Associated PCRs/CVs Inspection History Date 03/04/2005 03/04/2005 03/03/2005 03/03/2005 02/23/2005 02/23/2005 02/23/2005 02/23/2005 01/12/2005 01/11/2005 01/11/2005 01/07/2005 01/07/2005 Description 13 15 14 15 13 14 15 18 11 11 12 11 12 Shear Panels/HD's Roof/Reroof Frame/Steel/Bolting/Welding Roof/Reroof Shear Panels/HD's Frame/Steel/Bolting/Welding Roof/Reroof Exterior Lath/Drywall Ftg/Foundation/Piers Ftg/Foundation/Piers Steel/Bond Beam Ftg/Foundation/Piers Steel/Bond Beam Act CO CO we NR NR we NR we AP NR NR CO CO Ins) RB RB RB RB RB RB RB RB RB RB RB RB RB Comments 3RD TIME - PAY REINSP FEE - SEE NOTICE SEE NOTICE PAY RE-INSPEC FEE NO PLANS OR LADDER RESUBMIT CHANGES TO CITY (1106-E4) MP ACCESS TP [ER.OT TP SOGM SE NOTICE CITY OF CARLSBAD BUILDING DEPARTMENT NOTICE (760) 602-2700 1635 FARADAY AVENUE DATE 3 5 TIME. LOCATION PERMIT NO x-_ — _ t- /- /> ^ /J FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? ! _ ! YES FOR FURTHER INFORMATION, CONTACT _ PHONE 0ILDIN6 INSPECTOR A/S CODE ENFORCEMENT OFFICER 3 C. I I U urx -u tr «H aa -3u o•o o C g —I ->I -tj «- ec.c: K E-t MS =5 s= r- M n cn « o o o U o •5- -i<:a- T; iC:tl O W |ss S's E^ 3 e<q l-i t.. SM3: ae O* <*^ c^1 !/> -a1 «c- OJ C\J 3c. & Lo IX ^ c; u% •5oo. < _ -I ~l 3 JT *,£ f^ 05; " o P ^1 c. * 5 »h" :I1 *f III I5!!f! 3 Si5l|«sl-irslsn;SS??5^ 2o oooin ssn.i_L 90 92 City of Carlsbad Bldg Inspection Request For 03/04/2005 Permit# CB044125 Title DECARLO RES 90SF 1ST STORY RAD Description 490 SF 2ND STORY RAD Inspector Assignment RB Sub Type RAD 2716 MORNING GLORY LN Lot 0 Type RESDNTL Job Address Suite Location OWNER DECARLO FAMILY TRUST 06-14-94 Owner DECARLO LUDOVICO L JR Remarks Phone 6192469828 Inspector Total Time CD Description 13 Shear Panels/HD's 15 Roof/Reroof Requested By TOM Entered By CHRISTINE Act Comment Associated PCRs/CVs Inspection History Date Description Act Insp 02/23/2005 13 Shear Panels/HD's NR RB 02/23/2005 14 Frame/Steel/Boltmg/Welding WC RB 02/23/2005 15 Roof/Reroof NR RB 02/23/2005 18 Exterior Lath/Drywall WC RB 01/12/2005 11 Ftg/Foundation/Piers AP RB 01/11/2005 11 Ftg/Foundation/Piers NR RB 01/11/2005 12 Steel/Bond Beam NR RB 01/07/2005 11 Ftg/Foundation/Piers CO RB 01/07/2005 12 Steel/Bond Beam CO RB Comments RESUBMIT CHANGES TO CITY (1106-E4) MP ACCESS TP [ER.OTTP SOGM SE NOTICE T ( CITY OF CARLSBAD ^BUILDING DEPARTMENT DATE NOTICE (760) 602-2700 1635 FARADAY AVENUE TIME. LOCATION \ PERMIT NOi V 3 I ^ 1 ^ x/'«,- ' '/,O J>> S1'59'*0 JL/G, I S V' t ^ *&> /?-* £f^' /s-~* /?>/>/ Pf3 X. / / ,?'<***•& ^A j^_ , ^- FOFflNSPECTION CM.L (760) 602^725 FOR FURTHER INFORMATION, CONTACT _ __ __FFF ntJF? I : YFR PHONE ING INSPECTOR CODE ENFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For 02/23/2005 Permit* CB044125 Title DECARLO RES 90SF 1ST STORY RAD Description 490 SF 2ND STORX. Type/RESDNTL Sub Type RAD Job Address 2716 MORNING GLORY LN Suite\ Lot 0 Location OWNER DECARLO FAMILY TRUST 06-14-94 Owner DECARLO FAMILY TRUST 06-14-94 Remarks Total Time CD Description 14 Frame/Steel/Boltmg/Weldmg 15 Roof/Reroof Act Comment Inspector Assignment RB Phone 6192469828 Inspector Requested By TOM Entered By KAREN fr / ' / At//L - '~e.sc<^A(t</- c^^ / ^ )> Associated PCRs/CVs Inspection History Date Description Act Insp Comments 01/12/2005 11 Ftg/Foundation/Piers AP RB MP ACCESS TP [ER.OT TP SOGM 01/11/2005 11 Ftg/Foundation/Piers NR RB 01/11/2005 12 Steel/Bond Beam NR RB 01/07/2005 11 Ftg/Foundation/Piers CO RB 01/07/2005 12 Steel/Bond Beam CO RB SE NOTICE CITY OF CARLSBAD BUILDING DEPARTMENT DATE LOCATION PERMIT NO NOTICE (760) 602-2700 1635 FARADAY AVENUE A /^ ^ X FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? . YES FOR FURTHER INFORMATION, CONTACT PHONE NSPECTOR CODE ENFORCEMENT OFFICER ® City of Carlsbad Bldg Inspection Request For 01/12/2005 Permit* CB044125 Inspector Assignment RB Title DECARLO RES 90SF 1ST STORY RAD Description 490 SF 2ND STORY RAD Type RESDNTL Sub Type RAD Phone 6192469828 Job Address 2716 MORNING GLORY LN Suite Lot 0 Location Inspector APPLICANT TR JACKSON CONSTRUCTION & RENOVATION Owner DECARLO FAMILY TRUST 06-14-94 Remarks Total Time Requested By TOM Entered By JANEAN CD Description Act_^ Comjrnent 11 Ftg/Foundation/Piers Associated PCRs/CVs Inspection History Date Description Act Insp Comments 01/07/2005 11 Ftg/Foundation/Piers CO RB 01/07/2005 12 Steel/Bond Beam CO RB SE NOTICE NOTICE CITY OF CARLSBAD (760) 602-2700 BUILDING DEPARTMENT 1635 FARADAY AVENUE DATE /"^ /5> <X J TIME LOCATION PERMIT NO 7 FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? FOR FURTHER INFORMATION, CONTACT YES CODE ENFORCEMENT OFFICER ® City of Carlsbad Bldg Inspection Request For 01/11/2005 Permit# CB044125 Inspector Assignment RB Title DECARLO RES 90SF 1ST STORY RAD Description 490 SF 2ND STORY RAD Type RESDNTL Sub Type RAD Phone 6192469828 Job Address 2716 MORNING GLORY LN Suite Lot 0 Location Inspector APPLICANT TR JACKSON CONSTRUCTION & RENOVATION Owner DECARLO FAMILY TRUST 06-14-94 Remarks Total Time Requested By TOM Entered By CHRISTINE CD Description Act Comment 11 Ftg/Foundation/Piers 12 Steel/Bond Beam Associated PCRs/CVs Inspection History Date Description Act Insp Comments 01/07/2005 11 Ftg/Foundation/Piers CO RB 01/07/2005 12 Steel/Bond Beam CO RB SE NOTICE CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE (760) 602-2700 1635 FARADAY AVENUE TIME LOCATION / (> PERMIT NO FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? FOR FURTHER INFORMATION, CONTACT j YES PHONE CODE ENFORCEMENT OFFICER ® City oi Carlsbad Bldg Inspection Request For 01/07/2005 Permit* CB044125 Title DECARLO RES 90SF 1ST STORY RAD Description 490 SF 2ND STORY RAD Inspector Assignment Sub Type RAD 2716 MORNING GLORY LN Lot 0 Type RESDNTL Job Address Suite Location APPLICANT TR JACKSON CONSTRUCTION & RENOVATION Owner DECARLO FAMILY TRUST 06-14-94 Remarks Phone 6192469828 Inspector Total Time Requested By TOM Entered By CHRISTINE CD Description 12 Steel/Bond Beam -It Act Comment ^~ It *&- Associated PCRs/CVs Inspection History Date Description Act Insp Comments CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE (760) 602-2700 1635 FARADAY AVENUE TIME LOCATION / fc PERMIT NO / rii & /#c/ FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? I YES FOR FURTHER INFORMATION, CONTACT PHONE BUILDING INSPECTOR CODE ENFORCEMENT OFFICER ® APPLICANT a PLAN REVIEWER a FILE EsGil Corporation In (Partnership with government for (Bmftfing Safety DATE December 27, 2004 JURISDICTION Carlsbad PLAN CHECK NO 04-4125 SET III PROJECT ADDRESS 2716 Morning Glory Ln. PROJECT NAME De Carlo Residence Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Chris Ashley Telephone # In Person Date contacted (by ) F:ax # Mail Telephone Fax In Person REMARKS By Bill Elizarraras Esgil Corporation D GA D MB D EJ PC Enclosures LOG trnsmtl dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 <> (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In Partnership with government for (Buitding Safety DATE December 17, 2004 JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 04-4125 SET II PROJECT ADDRESS 2716 Morning Glory Ln. PROJECT NAME De Carlo Residence Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck [X] The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Terry Montello 4715 60th St San Diego, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Terry Montello Telephone # 619-994-5557 Date contacted / ^{ iJ l^(by far) Fax # fatf) 1'tf O^^Z. Mail ^Telephone Fax^ In Person REMARKS By Bill Elizarraras Enclosures Esgil Corporation D GA D MB D EJ D PC 12/09/04 tmsmtldot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 «> (858)560-1468 * Fax (858) 560-1576 Carlsbad 04-4125 December 17, 2004 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad PLAN CHECK NO 04-4125. PROJECT ADDRESS 2716 Morning Glory Ln. SET II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 12/09/04 December 17, 2004 REVIEWED BY Bill Elizarraras FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit two new complete sets of prints to ESGIL CORPORATION B To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? G Yes a No Carlsbad O4-4125 December 17, 2004 • The following corrections are from the original deficiency list, and were either not addressed or a result of new changes. • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit two sets of plans for residential projects For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments 2 Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation Specify expiration date of license (California Business and Professions Code) 3 Provide drag truss and throe point bearing details and truss calculations for this project Specify truss identification numbers on the plans Drag truss details were not received. 4 Please provide evidence that the engmeer-of-record has reviewed the truss calculation package prepared by others (i e , a "review" stamp on the truss calculations or a letter) Section 106 3 4 1 Letter was not received. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes a No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bill Elizarraras at Esgil Corporation Thank you EsGii Corporation In (Partnership with government for (BuiCding Safety DATE December 1, 2004 ^=O=A£mCANT -a JURIS. JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO O4-4125 SET I PROJECT ADDRESS 2716 Morning Glory Ln. PROJECT NAME De Carlo Residence Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes I | The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck X] The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person X] The applicant's copy of the check list has been sent to Terry Montello 4715 60th St San Diego, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed X] Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Terry Montello Telephone # 619-994-5557 Date contacted 12-11 }^\ (by ) Fax # (b>°i} £2 <? oU>^2_. Mail ^ Telephone Fax -^ In Person REMARKS By Bill Elizarraras Enclosures Esgil Corporation D GA D MB D EJ D PC 11/16/04 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576 Carlsbad O4-4125 December 1, 20O4 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO O4-4125 JURISDICTION Carlsbad PROJECT ADDRESS 2716 Morning Glory Ln. FLOOR AREA 580 sq ft Dwelling Add'n STORIES 2 HEIGHT 26' REMARKS DATE PLANS RECEIVED BY JURISDICTION DATE INITIAL PLAN REVIEW COMPLETED December 1, 2004 DATE PLANS RECEIVED BY ESGIL CORPORATION 11/16/04 PLAN REVIEWER Bill Elizarraras FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24), which adopts the following model codes 1997 UBC, 2000 UPC, 2000 UMC and 1999 NEC (all effective 11/1/02) The above regulations apply to residential construction, regardless of the code editions adopted by ordinance The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad O4-4125 December 1, 2004 • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit two sets of plans for residential projects For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments 2 Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation Specify expiration date of license (California Business and Professions Code) 3 Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 edition of the California Building Code (Title 24), which adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 1999 NEC 4 On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below Section 106 3 2 • REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec 1701 of the Uniform Building Code ITEM REQUIRED? REMARKS • EPOXY ANCHORS 5 When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit Please review Section 106 3 5 Please complete the attached form 6 Specify on the plans the following information for the deck finish materials, per Section 1063 3 a) Manufacturer's name b) Product name/number c) ICBO approval number, or equal Carlsbad O4-4125 December 1, 2004 7 Balconies and decks exposed to the weather and sealed underneath shall be sloped a minimum of % inch per foot for drainage Section 1402 3 8 Specify size, I C B O number and manufacturer of epoxy anchors Show edge and end distances and spacing Section 106 3 3 9 Show size and embedment of hold down anchors for epoxy applications on foundation plan Section 106 3 3 10 Provide drag truss and three point bearing details and truss calculations for this project Specify truss identification numbers on the plans 11 Please provide evidence that the engmeer-of-record has reviewed the truss calculation package prepared by others (i e , a "review" stamp on the truss calculations or a letter) Section 106 3 4 1 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in ihe plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bill Elizarraras at Esgil Corporation Thank you Carlsbad O4-4125 December 1, 20O4 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PLAN CHECK NO O4-4125 PREPARED BY Bill Elizarraras DATE December 1, 2004 BUILDING ADDRESS 2716 Morning Glory Ln. BUILDING OCCUPANCY R3/U1 TYPE OF CONSTRUCTION VN BUILDING PORTION Dwelling Add'n Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 580 cb Valuation Multiplier Per City Value By Ordinance Reg Mod VALUE ($) 63,800 63,800 $398 96 Plan Check Fee by Ordinance Type of Review I I Repetitive Fee ~] Repeats 0 Complete Review D Other D Hourly Structural Only Hour* Esgil Plan Review Fee $259 32 $223 42 Comments Sheet 1 of 1 macvalue doc CORP Fax:18585601576 Mav 22 2004 15-40 P 05 Oceanside O4-153O November 19, 2QO4 [SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: ^71U PLAN CHECK NUMBER: cA'^\1^ OWNERS NAME;1P& I, as the owner, or agent of the owner (contractors may noj employ the special Inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special inspectors) as required by Uniform Building Code (UBC) Section 1701.1 for the construction project located at the site listed above. UBC Section 106.3.5 Signed I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106 3.5 for the construction project the site Hated above. Signed 1. List of work requiring special inspection: D Soils Compliance Prior to Foundation Inspection Structural Concrete Over 2500 PSI Preatrsssed Concrete Structural Masonry Designer Specified J Field Welding 3 High Strength Bolting 1 Expansion/Epoxy Anchors I Sprayed-On Fireproofing Other 2, Name(s) of Individual(s) or firm(s) responsible for the special inspections listed above: A, B, C. 3. Duties of the special Inspectors for the work listed above; A, c. Spccual inspectors shall check m wim the City and present their crederrtjate for approval fiflcrjft Oeetf"»nfl vw« on w« /ob ate City of Carisba v ••^••HPM^^MVWnPHHHH^BB^^n^V^^^^^MlP'u bill c Wbjrks;.;—, Eirigiinee*i ngI BUILDING PLANCHECK CHECKLIST DATE BUILDING ADDRESS PROJECT DESCRIPTION £gS IPgNTIAU ASSESSOR'S PARCEL NUMBER 156? - 12 0 ' ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved The approval is based on plans, information and/or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build _i A Right-of-Way permit is required prior to construction of the following improvements EST VALUE DENIAL Please see the attached report of deficiencies marked with D Make necessary corrections to plans or specifications for compliance with applicable codes and standards Submit corrected plans and/or specifications to this office for review By By By Date Date Date FOR OFFICIAL USE ONLY GINEERING AUTHORIZATION TO ISSUE BUILDING PERMIjl JH&Oa,e ATTACHMENTS !_J Dedication Application D Dedication Checklist C Improvement Application G improvement Checklist U Future Improvement Agreement L_' Grading Permit Application •_J Grading Submittal Checklist '_ Right-of-Way Permit Application ~_ Right-of-Way Permit Submittal Checklist and Information Sheet — Sewer Fee Information Sheet Name ENGINEERING DEPT CONTACT PERSON Linda Ontiveros City of Carlsbad Address 1635 Faraday Avenue. Carlsbad, CA 92008 Phone (760) 602-2790 CFD INFORMATION Parcel Map No Lots Recordation Carlsbad Tract \J n \ , CA 92008-7314 • (760) 602-272O • FAX (760) 6O2*SS6>2 BUILDING PLANCHECK CHECKLIST ,ST ,RD D D D SITE PLAN 1 Proyttie a fully dimensioned site plan drawo,to~scale Show Fx/,Right-of-Way Width & Adjacent Streets <*j Driveway widths H Existing or proposed sewer lateral I Existing or proposed water service J Existing or proposed irrigation service forth Arrow 'Existing & Proposed Structures <istmg Street Improvements D/ Property Lines E Easements 2 Show on site plan A Drainage Patterns 1 Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course 2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building " B Existing & Proposed Slopes and Topography C Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception D Sewer and water laterals should not be located within proposed driveways, per standards 3 Include on title sheet Parcel Number egal Description For commercial/industrial buildings and tenant improvement projects, include total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc ) previously approved EXISTING PERMIT NUMBER DESCRIPTION f \ENG TECH COUNTERSBUILDING PLANCHECK CKLST FORM doc BUILDING PLANCHECK CHECKLIST 3HU DISCRETIONARY APPROVAL COMPLIANCE D D 4a Project does not comply with the following Engineering Conditions of approval for Project No 4b All conditions are in compliance Date DEDICATION REQUIREMENTS 5 Dedication for all street Rights-of-Way adjacent to the building site and any storm dram or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 15.000 . pursuant to Carlsbad Municipal Code Section 18 40 030 Dedication required Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 1/2" x 11" plat map and submit with a title report All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit Attached please find an application form and submittal checklist for the dedication process Submit the completed application form with the required checklist items and fees to the Engineering Department in person Applications will not be accept by mail or fax Dedication completed by Date IMPROVEMENT REQUIREMENTS 6a All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $_75,000 . pursuant to Carlsbad Municipal Code Section 1840040 Public improvements required as follows Attached please find an application form and submittal checklist for the public improvement requirements A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process The completed application form and the requirements on the F \ENG TECH COUNTEFRBUILDING PLANCHECK CKLST FORM dm BUILDING PLANCHECK CHECKLIST . ST ,RD D D checklist must be submitted in person Applications by mail or fax are not accepted Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit Improvement Plans signed by Date 6b Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 1840 Please submit a recent property title report or current grant deed on the property and processing fee of $310 so we may prepare the necessary Neighborhood Improvement Agreement This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit Future public improvements required as follows D D 6c Enclosed please find your Neighborhood Improvement Agreement Please return agreement signed and notarized to the Engineering Department i Neighborhood Improvement Agreement completed by Date 6d No Public Improvements required SPECIAL NOTE Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy D C3 GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11 06 030 of the Municipal Code 7a Inadequate information available on Site Plan to make a determination on grading requirements Include accurate grading quantities (cut, fill import, export) 7b Grading Permit required A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached NOTE The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit D Grading Inspector sign off by Date 7c Graded Pad Certification required (Note Pad certification may be required even if a grading permit is not required ) F \ENG TECH COUNTEFMUILDING PLANCHECK CKLST FORM doc ,ST D D D BUILDING PLANCHECK CHECKLIST 7d No Grading Permit required 7e If grading is not required, write "No Grading" on plot plan MISCELLANEOUS PERMITS 8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right of-Way Types of work include, but are not limited to street improvements, tree trimming, driveway construction, tying into public storm dram, sewer and water utilities Right-of-Way permit required for D D D D D INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contad the Carlsbad Municipal Water District, located at 5950 El Cammo Real, Carlsbad, CA 92008 District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List You may telephone (760) 438-2722, extension 7153, for assistance Industrial Waste permit accepted by Date 10 NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first""' 11 Required fees are attached No fees required WATER METER REVIEW 12a Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized Oversized meters are inaccurate during low-flow conditions If it is oversized for the life of the meter, the City will not accurately bill the owner for the water used • All single family dwelling units received "standard" 1" service with 5/8" service F \ENG TECh COUNTEFSBUILDING PLANCHECK CKLST FORM doc , ST ,RD D 12b BUILDING PLANCHECK CHECKLIST • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm) A typical fixture count and water demand worksheet is attached Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit • Maximum service and meter size is a 2" service with a 2" meter • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand (manifolds are considered on case by case basis to limit multiple trenching into the street) Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval The developer must provide these calculations Please follow these guidelines 1 If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets If so, at the water meter station, the demand in gpm may be listed there Irrigation services are listed with a circled "I", and potable water is typically a circled "W" The irrigation service should look like STA 1+00 Install 2" service and 1 5 meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach) Typically, Larry Black has already reviewed this if landscape plans have been prepared but the applicant must provide the calculations to you for your use Once you have received a good example of irrigation calculations, keep a set for your reference In general the calculations will include • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PS!) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA) As long as the project is located within the City recycled water F \ENG TECH COUNTEFRBUILDINO PLANCHECK CKLST FORM doc ..ST 2ND 3RD BUILDING PLANCHECK CHECKLIST service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future 12c Irrigation Use (where recycled water is available) 1 Recycled water meters are sized the same as the irrigation meter above 2 If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development For subdivisions, this should have been identified, and implemented on the improvement plans Installing recycled water meters is a benefit for the applicant since they are exempt fiom paying the San Diego County Water Capacity fees However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this D D D 13 Additional Comments- F \ENS TECH COUNTER\BUILDING PLANCHECK CKLST FORM doc \ £ £ £ S S 8 666 c c c an an PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No CB Planner A/1 • APN Address Phone (760) 602- Type of Project & Use Zoning fir I General Plan CFD (m/out) #_Date of participation Net Project Density. Facilities Management Zone ff U/AC Remaining net dev acres. Circle One (For non-residential development Type of land used created by this permit ) Legend: |3 Item Complete D Item Incomplete - Nee'ds your action Environmental Review Required: YES NO Y TYPE DATE OF COMPLETION Compliance with conditions of approval? If not, state conditions which require action Conditions of Approval L Discretionary Action Required: APPROVAL/RESO NO PROJECT NO YES TYPE . DATE OTHER RELATED CASES Compliance with conditions or approval9 If not, state conditions which require action. Conditions of Approval Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES CA Coastal Commission Authority? YES If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402, (619)767-2370 Determine status (Coastal Permit Required or Exempt) Coastal Permit Determination Form already completed? YES NO If NO, complete Coastal Permit Determination Form now Coastal Permit Determination Log # Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed Inclusionary Housing Fee required: YES NO X (Effective date of Inclusionary Housing Ordinance - May 21,1993) Data Entry Completed' YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE') Site Plan: H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes) Provide legal description of property and assessor's parcel number Policy 44 - Neighborhood Architectural Design Guidelines 1 Applicability YES NO X^ D n l~~l 2 Project complies YES Zoning: fef D D 1 Setbacks: Front Interior Side Street Side Rear Top of slope. STuH D 2 Accessory structure setba FronK. / Interior J&wre. StreeTSlaV Rear \ Structure separation Q D D 3- Lot Coverage JXJ D D 4 Height STd D 5 Parking. Spaces (breakdown by Residential Guest Spaces Re< [~~1 PI l~l Additional Comments — ^ NO Required *^Cs Required / O Required (,O Required -*" Required icks: Required Required Required Required Required ^~ ^"~f ORequired I ^ Required Required ^"~ uses for commercial and quired Shown "Z-^ Shown l~2— Shown ( ^7 Shown — — Shown Shown Shown Shown Shown Shown i "/ ^- (//) f/f' Shown ^ tu f' Shown 2-"^ Shown industrial projects required) Shown , OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER H \ADMIN\COUNTER\BldgPlnchkRevChklst 4^DATE Rev 9/01 03-25-2004 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No PCR04018 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # Project Title Applicant GARY GILBERT 2325 PIO PICO DR 92008 760 720-0965 2323 PIO PICO DR CBAD PCR 1563500500 Lot# 0 $0 00 Construction Type NEW GILBERT RES-MOVE WINDOWS FROM ORIGN PLANS Status Applied Entered By Plan Approved Issued Inspect Area Owner GILBERT LIVING TRUST 08-02-85 2810ELMWOODST CARLSBAD CA 92008 ISSUED 01/26/2004 MEL 03/25/2004 03/25/2004 Plan Check Revision Fee Additional Fees $12000 $000 Total Fees $12000 Total Payments To Date $000 Balance Due $12000 8335 03/25/04 0002 01 02 CGF" 120 = PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 ip>fiblECt INFORMATION „ OFFICE USE ONLY PLAN CHECK NO EST VAL Plan Ck Deposit Validated By Date .Address (include Qdg/Suita#)Fio Pti.0 Dr Business Name (at this address) Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor's Parcel #Existing Use Proposed Use Name Address City ilQjfcomlctorji,GlAgent.for.Contragto|:/iLU,Owner .,GJ'Agent foriOwner. ff ~ .^ •*'' ^f ry rt -—— f"j T f) j*f\ /^ State/Zip Telephone Fax # Name Address City State/Zip Telephone ff Name Address City State/Zip Telephone # (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) Name State License ff Address License Class City State/Zip City Business License # Telephone # Designer Name State License # Address City State/Zip Telephone Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations Q I have and will maintain a certificate of consent to self insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued n I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My worker's compensation insurance carrier and policy number are Insurance Company Policy No Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS) Q CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees SIGNATURE DATE ;_.,.-_-WL.-^e,..- ...fr..:^..^^'*.-.":.-?:-. • ..^,:...-. j.,.;.;. j. .;.^ ., .>-_•: -."V - . -£ I hereby affirm that I am exempt from the Contractor's License Law for the following reason n I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) l~l I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) (H I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement Q YES QNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE, NO [O^LETEJHMS^^ ,.:._- :-V-w... *".. ;;.-,.-. :;;.-.-.r-,_.. ' Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? C] YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? O YES Q NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT te^jcpj«sjml<^^^ ;_["•; _;_:_ .liL.:: _ j^; \_ __ __;_. ;.:/:'£•:"•• :^' £ " * I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code) LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building cons property for inspection purposes I ALSO AGREE T JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN OSHA An OSHA permit is requireojcr excavations over EXPIRATION Every permit issued iiwhe building Official authorized by such permit is not co at any time after the work is com '1 within 180 da APPLICANT'S SIGNATURE I hereby authorize representatives ol the CitV of Carlsbad to enter upon the above mentioned iVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, 'AY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT leap arij/demohtion or construction of structures over 3 stories in height TS-ef this Code shall expire by limitation and become null and void if the building or work ite offeuch permit or if the building or work authorized by such permit is suspended or abandoned in 186 4 4 Uniform Building Code) DATE WHITE File YELLOW Applicant PINK Finance EsGil Corporation In (Partners Rip with government for <Buififing Safety DATE March 22, 20O4 JURISDICTION Carlsbad PLAN CHECK NO PCR04-018 (Orig.02-2578) SET II PROJECT ADDRESS 2323 Pio Pico Dr. PROJECT NAME Revisions to The Gilbert Residence a AEEtJCANT a PLAN REVIEWER a FILE XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person LI The applicant's copy of the check list has been sent to X] Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax Mail Telephone Fax In Person s^ REMARKS Sheets 4 and 5 (Resubmitted set II) musjNre slip sheeted into set I of revised owner set of plans s By Bill Elizarraras Esgil Corporation D GA D MB D EJ D PC Enclosures 3/15/04 trnsmtldot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 * (858)560-1468 4 Fax (858) 560-1576 EsGil Corporation In Partnership with Gcnernment for Building Safety DATE February 4, 2004 CLABBLICANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO PCR04-018 (Orig02-2578) SET I PROJECT ADDRESS 2323 Pio Pico Dr. PROJECT NAME Revisions to The Gilbert Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to BC Drafting 71 OS Rancho Santa Fe Rd San Marcos, CA 92069 Esgil Corporation staff did not advise the applicant that the plan check has been completed X3 Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Bob Carlm Telephone # 760-597-2900 Date contacted dM^M (by/IS) (W^ Fax # Mailx/ Telephone» Fax In Person REMARKS By Bill Elizarraras Enclosures Esgil Corporation D GA D MB D EJ D PC 9/3/02 trnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (858)560-1468 + Fax (858) 560-1576 Carlsbad PCRO4-018 (Orig02-2578) February 4, 2O04 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO PCRO4-O18 (Orig02-2578) JURISDICTION Carlsbad PROJECT ADDRESS 2323 Pio Pico Dr. FLOOR AREA 3072 sqft Dwelling 480 sqft Garage REMARKS DATE PLANS RECEIVED BY JURISDICTION DATE INITIAL PLAN REVIEW COMPLETED February 4, 2004 STORIES 2 HEIGHT 29'-6" DATE PLANS RECEIVED BY ESGIL CORPORATION 9/3/02 PLAN REVIEEWER Bill Elizarraras FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Present California law mandates that residential construction comply with the 1998 edition of the California Building Code (Title 24), which adopts the following model codes 1997 UBC, 1997 UPC, 1997 UMC and 1996 NEC (all effective 7/1/99) The above regulations apply to residential construction, regardless of the code editions adopted by ordinance The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad PCR04-O18 (OrigO2-2578) February 4, 20O4 • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 2 Plans, specifications and calculations shall be signed and sealed by the California State licensed engineer or architect responsible for their preparation Specify expiration date of license (California Business and Professions Code) 3 The proposed changes must be reflected on all structural pages of plans (Roof and floor framing plans) To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bill Elizarraras at Esgil Corporation Thank you Carlsbad PCRO4-O18 (OrigO2-2578) February 4, 2OO4 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PLAN CHECK NO PCR04-O18 (Orig02-2578) PREPARED BY Bill Elizarraras DATE February 4, 2004 BUILDING ADDRESS 2323 Pio Pico Dr. BUILDING OCCUPANCY R3/U1 TYPE OF CONSTRUCTION VN BUILDING PORTION Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) cb Blrln Pprmif FPP hu OrHinanrp ^ Valuation Multiplier By Ordinance Reg Mod VALUE ($) Plan Check Fee by Ordinance $120 00 Type of Review /^Repetitive Fee v] Repeats * Based on hourly rate Comments D Complete Review D Other m Hourly Structural Only Hour* Esgil Plan Review Fee $9600 Sheet 1 of 1 macvalue doc 05-05-20G5 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No PCR05070 Building Inspection Request Line (760) 602-2725 Job Address 2716 MORNING GLORY LN CBAD Permit Type PCR Parcel No 1561203300 Lot# Valuation $0 00 Construction Type Reference* CB044125 Project Title DECARLO RES REV TO RAFTER ADD FAU PLATFORM 0 NEW Status Applied Entered By Plan Approved Issued Inspect Area Applicant MONTELLO GEORGE 471560THST SAN DIEGO CA 92115 619229-0642 Owner DECARLO LUDOVICO L JR 2716 MORNING GLORY LN CARLSBAD CA 92008 ISSUED 04/11/2005 SB 04/22/2005 04/22/2005 Plan Check Revision Fee Additional Fees $12000 $000 Total Fees $12000 Total Payments To Date $0 00 Balance Due $12000 7591 05/05/05 0002 01 02 CGP 120-00 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as 'fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired i PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635^Faraday Ave , Carlsbad, CA 92008 Address (include Bldg/SuiteJr) FOR OFFICE USE^ONLY. PLAN CHECK N EST VAL Plan Ck Deposit Validated Date /•££• *' i, < Business Name (.it this address) Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor s Parcel # vraftir rtfttfl\Lr Existing Use Proposed Use SQ FT #of Stones froirvapplicaivt)mm Tenth ,fh # of Bedrooms # of Bathrooms dug ^fag-)<W ~ Address ' City D'Owner ;«[D Agqjt for Owner.; State/Zip Telephone Fax # Name 4 PROPERTY OWNER, Address City State/Zip Telephone ff Address City State/Zip Telephone #Name ,5 X CONfRACTOR|jCO|\flPANY NAME ,; .• »~ ";v T .. ""SC...:::: *I::& Jw;:.,.; :,:..»,:.•: ai V (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct alter, improve demolish or repair any structure prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name Address City State/Zip Telephone State License # :6 ....-WORKERS^ COMPENSATION. •;.ii;h.!h " "' " '"^..,. '%,<:. "ik" — - - - - -.-r; •-• - ~- : i Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations n I have and will maintain a certificate of consent to self insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued r~l I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My worker's compensation insurance carrier and policy number are Insurance Company Policy No Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) l~l CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100 000) in addition to the cost of compensation damages as provided for in Section 3706 of the Labor code interest and attorney s fees SIGNATURE DATE :7': OWNER-BUILblRlDECLARATION " "..,:.. - • ". ::ir. —• •:"': ;?;: ' . . " '^ '- :.., ,„.,. '• Ji I hereby affirm that I am exempt from the Contractor s License Law for the following reason 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) [~1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) PI I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement l~l YES f~lNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide this work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE . BUILDING PJERMITSJONLY , -,„ „ Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act? O YES l~l NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' (~l YES l~l NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site' d YES C] NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER S NAME 9 APPUCA¥T CERTIFICATION LENDER S ADDRESS_ 7. " "Tip?"" I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height EXRRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned m any time after the work is commence^? for a period ot/fsQpSatys (Section 106 4 4 Uniform Building Code) 4I . . '*// 'i ' S.GNATURE // DATE YELLOW Applicant PINK Finance ? EsGil Corporation In (Partnership with government for (BuiCding Safety DATE April 22, 2005 JURISDICTION Carlsbad Q ROW-REVIEWER a FILE PLAN CHECK NO PCR05-70 (Orig. 04-4125) SET I PROJECT ADDRESS 2716 Morning Glory Ln. PROJECT NAME Revisions for The De Carlos Residence Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) F'ax # Mail Telephone Fax In Person XI REMARKS Plans must be stamped and signed by Engineer By Bill Elizarraras Enclosures Esgil Corporation D GA D MB D EJ D PC 4/14/05 tmsmtldot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4> (858)560-1468 * Fax (858) 560-1576 Carlsbad PCR05-7O (Orig. 04-4125) April 22, 2005 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PLAN CHECK NO PCR05-70 (Orig. 04-4125) PREPARED BY Bill Elizarraras DATE April 22, 20O5 BUILDING ADDRESS 2716 Morning Glory Ln. BUILDING OCCUPANCY R3/U1 TYPE OF CONSTRUCTION VN BUILDING PORTION Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) cb Valuation Multiplier By Ordinance Reg Mod VALUE ($) Bldg Permit Fee by Ordinance ^ j Plan Check Fee by Ordinance $120 00 Type of Review D Repetitive Fee Repeats D Complete Review D Other m Hourly Structural Only Hour1 Esgll Plan Review Fee $9600 * Based on hourly rate Comments Sheet 1 of 1 macvalue doc