HomeMy WebLinkAbout2718 GATEWAY RD; ; CB100721; Permit07-12-2010 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB100721 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: Applicant: 2718 GATEWAY RD CBAD Tl Sub Type: COMM 2132631500 Lot#: 0 Status: ISSUED $250,880.00 Construction Type: 5B Applied: 04/27/2010 Reference #: Entered By: RMA FLOORING AMERICA-7168 SF SHELL Plan Approved: 07/12/2010 (702 SF SHELL TO WAREHOUSE, 4478 SF SHELL TO SHOWROOM, Issued: 07/12/2010 Inspect Area: Plan Check#: Owner: TK&C PROPERTIES INC 9220 TRADE PL 92126 858271-1820 SPECTRUMFLEX LLC 406 9TH AVE #309 SAN DIEGO CA 92101 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Fire Expedited Plan Review $1,195.57 Meter Size $0.00 Add'l Reel. Water Con. Fee $777.12 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $52,68 PFF (3105540) $0.00 PFF (4305540) $0.00 License Tax (3104193) $0.00 License Tax (4304193) $0.00 Traffic Impact Fee (3105541) $0.00 Traffic Impact Fee (4305541) $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $5,060.00 Master Drainage Fee D3/4 Sewer Fee $0.00 Redev Parking Fee $0.00 Additional Fees $8.00 HMP Fee $227.50 TOTAL PERMIT FEES $0.00 $364.00 $4,492.00 $435.81 $4,566.02 $0.00 $0.00 $0.00 $3,138.80 $0.00 $97.00 $210.00 $75.50 $0.00 $4,509.01 $0.00 $0.00 $25,209.01 Total Fees:$25,209.01 Total Payments To Date:$25,209.01 Balance Due:$0.00 Inspector: FINAL APPROVAL Date: J/'Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as lees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717/2718/2719 Fax: 760-602-8558 www.caflsbadca.gov JOB ADDRESS SUITE#/SPACE#/UNIT# CT/PROJECT#PHASE # # OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) PROPOSEDXlSE ARAGE (SF) /PAT/OS (SF)DECKS (SF) CONTACT NAME (If Different Fom Applicant)APPLICANT NAME ADDRESS ADDRESS tou CITY STATE ZIP CITY iTATE Mr PHONE FAX PHONE FAX EMAIL EMAIL p f OWNER NAME ADDRESS ^Ty?CITY STATE (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the'. . , , , , ,applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by a ------ " — * * ------- :* ~ •'-•--••- " ----- " — ' *- -civil penalty of not more than five hundred dollars {$500}).L.5 by any applicant for a permit subjects the applicant to a Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations: O I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. n I have and will maintain workers' compensation's requiredby Section 3700 of the Labor Codejor the performance of the work for which thisjaermit is issued. My workers' compensation jfisujance carrier and policy number are: Insurance Co. fyiCfy^dC 1\ &*"<*** ff^fU^f^JS^ K) Policy No. I&C?OOQB Of S" I OI Expiration Date /(if\\f This section need not be completed if the permit is for one hundred dollars ($100) or less. n Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100.000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. CONTRACTOR SIGNATURE [~l AGENT DATE / hereby affirm that I am exempt from Contractor's License Law for the following reason: n I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). )( I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law). n I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. O Yes 2.1 (ffave)/ haiw-net) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone /contractors' license number): ~\ B>*> 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (ind ude name / address / phone / contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): ^PROPERTY OWNER SIGNATURE nAGENT DATE -U-7-IO Is the applicant O5&iture building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? O Yes O No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? a Yes a No Is the faciIKH to be constructed within 1,000 feet of the outer boundary of a school site? a Yes D No IF ANY OF*tHE ANSWERS ARE YES, I EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the BuildjfiSfOlffcial under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or ifJUeDuildirg'or work authorized by such pejmit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). JS!) APPLICANT'S SIGNATURE { </'^( ^•"'V_—~-x''^XvIII5" DATE3NAJURE City of Carlsbad Final Building Inspection Dept: Building Engineering Planning CMWD St Lite Fire Plan Check #: Permit #: Project Name: Address: Contact Person: Sewer Dist: Inspected / Bv: (i 7Inspected I Bv: Inspected Bv: Comments: CB1 00721 FLOORING AMERICA-7168 SF SHELL (702 SF SHELL TO WAREHOUSE, 4478 SF 271 8 GATEWAY RD JOSH Phone: 7602717723 CA Water Dist: CA ^ Date / / M^ Inspected: I^W 1 / '' Date Inspected: Date Inspected: Date: Permit Type: Sub Type: SHELL TO S Lot: 0 1j£$> Approved: / Approved: Approved: 10/22/2010 Tl COMM Disapproved: Disapproved: Disapproved: City of Carlsbad Bldg Inspection Request For: 11/01/2010 Permit* CB100721 Title: FLOORING AMERICA-7168 SF SHELL Inspector Assignment: RB Description: (702 SF SHELL TO WAREHOUSE, 4478 SF SHELL TO SHOWROOM, 1988 SF SHELL TO OFFICE) Sub Type: COMM 2718 GATEWAY RD Lot: Type: Tl Job Address: Suite: Location: APPLICANT TK&C PROPERTIES INC Owner: SPECTRUMFLEX LLC Remarks: Total Time: Phone: 7602717723 Inspector: Requested By: JEFF Entered By: CHRISTINE CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act ^Comments Comments/Notices/Holds Associated PCRs/CVs/SWPPPs Original PC# Inspection History Date 10/28/2010 10/22/2010 10/12/2010 10/07/2010 10/07/2010 09/24/2010 09/02/2010 08/24/2010 08/24/2010 08/24/2010 08/24/2010 08/17/2010 08/17/2010 Description 89 89 39 15 44 84 17 14 24 34 44 14 17 Final Combo Final Combo Final Electrical Roof/Reroof Rough/Ducts/Dampers Rough Combo Interior Lath/Drywall Frame/Steel/Bolting/Welding Rough/Topout Rough Electric Rough/Ducts/Dampers Frame/Steel/Bolting/Welding Interior Lath/Drywall Act CA CA PA we AP AP AP AP AP AP NR PA we Insp TP RB RB RB RB RB RB RB RB RB RB RB RB Comments OK FOR METER RELEASE @ ROOF EQUIPMENT T-BAR SYSTEM WALLS ONLY WALLS ONLY SEE JOB PLANS ELECTRIC IMC. 11657 Riverside Drive, #165 Lakeside, CA 92040 (619) 456-4500 fax (619) 456-4501 TORQUE REPORT Transformer/Panel Board Location Name All connections torqued per manufactured specifications to: SIZE INCH LBS Allen screws 1/2" 3/8" 5/16" Hex Bolts 1/4" 3/8" 1/2" 500 375 275 72 240 600 j P*Acl / Z^S-ftA /,-«<*/'/ Signature City of Carlsbad Bldg Inspection Request For: 08/10/2010 Permit# CB100721 Title: FLOORING AMERICA-7168 SF SHELL Inspector Assignment: RB Description: (702 SF SHELL TO WAREHOUSE, 4478 SF SHELL TO SHOWROOM, 1988 SF SHELL TO OFFICE) 2718 GATEWAY RD Lot: Type:TI Sub Type: COMM Job Address: Suite: Location: APPLICANT TK&C PROPERTIES INC Owner: SPECTRUM FLEX LLC Remarks: Phone: 7602717723 Inspector: Total Time: CD Description 21 Underground/Under Floor 14 Frame/Steel/Bolting/Welding 24 Rough/Topout 34 Rough Electric 44 Rough/Ducts/Dampers Requested By: JEFF? Entered By: JANEAN Act Comments Comments/Notices/Holds Associated PCRs/CVs/SWPPPs Original PC# Date 08/06/2010 08/06/2010 08/02/2010 08/02/2010 07/28/2010 07/28/2010 07/28/2010 07/14/2010 07/14/2010 07/14/2010 Inspection History Description 14 34 14 44 14 15 44 14 15 44 Frame/Steel/Bolting/Welding Rough Electric Frame/Steel/Bolting/Welding Rough/Ducts/Dampers Frame/Steel/Bolting/Welding Roof/Reroof Rough/Ducts/Dampers Frame/Steel/Bolting/Welding Roof/Reroof Rough/Ducts/Dampers Act NR NR AP we we AP we we CO we Insp TP TP RB RB RB RB RB RB RB RB Comments NO SUPP., LOC OF INSP? EQUIPMENT PLATFORM FRMG ROOF FRAMING FOR ROOF EQUIPMENT SEE NOTICE FOR ROOF EQUIPMENT :*' . f CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE LOCATION PERMIT NO. (760)602-2700 1635 FARADAY AVENUE TIME T&-7 y *,~/ FOR INSPECTION CALL (760) 602-2725. RE-INSPECTION FEE DUE? FOR FURTHER INFORMATION, CONTACT YES PHONE BUILDING INSPECTOR CODE ENFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For: 07/28/2010 Permit# CB100721 Title: FLOORING AMERICA-7168 SF SHELL Inspector Assignment: RB Description: (702 SF SHELL TO WAREHOUSE, 4478 SF SHELL TO SHOWROOM, 1988 SF SHELL TO OFFICE) 2718 GATEWAY RD Lot: Type:TI Sub Type: COMM Job Address: Suite: Location: APPLICANT TK&C PROPERTIES INC Owner: SPECTRUMFLEX LLC Remarks: Phone: 7602717723 Inspector: Total Time: CD Description 14 Frame/Steel/Bolting/Welding 44 Rough/Ducts/Dampers Act Comments Requested By: JEFF Entered By: JANEAN <>)r f> Com ments/Notices/Holds Associated PCRs/CVs/SWPPPs Original PC# Inspection History Date Description Act Insp Comments 07/14/2010 14 Frame/Steel/Bolting/Welding WC RB 07/14/2010 15Roof/Reroof CO RB SEE NOTICE FOR ROOF EQUIPMENT 07/14/2010 44 Rough/Ducts/Dampers WC RB INOTES:. ^- CD_Q "CD_cto CO1oto en CD limumL. "E CD CD Jl C CD Diameterc 'CDE J3 CM •»- CM M—O •*-<embedmemember.crewsto COJD C O 0 CD Q. '3cr LJJ CM x^-o-*-• +2 CDccoo CD.a "CD to CDXCO 1oo^ *5 Q. <5 membersCMu CD "E CD E 1 'c 'coc CD_Q t:CDE .. O CO ^ .9- CD CD= -Q j& ^ lil « || CM CO E C ! \V '/ ^ • '" T' ! '"1""^*' ': • ' w "o i i i i H>^; ; ! : • • ;SW>:| ; ; ' : i ; : : : i ii i . •£ » !•:•:'' . i ; i ^J • 'j i 1 -1 1 ; ! i I !'• M . • . 1^ ••«^Q 5« ..3 ; l^ T; •*n City of Carlsbad Bldg Inspection Request For: 07/14/2010 Permit* CB100721 Title: FLOORING AMERICA-7168 SF SHELL Inspector Assignment: Description: (702 SF SHELL TO WAREHOUSE, 4478 SF SHELL TO SHOWROOM, 1988 SF SHELL TO OFFICE) Sub Type: COMM 2718 GATEWAY RD Lot: Type:Tl Job Address: Suite: Location: APPLICANT TK&C PROPERTIES INC Owner: SPECTRUMFLEX LLC Remarks: Phone: 7602717723 Inspector: Total Time: CD Description 14 JFjra^e/Steel/Bjplting/Weldin 44 Rough/Ducts/Dampers Requested By: JEFF Entered By: CHRISTINE Comments/Notices/Holds Associated PCRs/CVs Original PC# Inspection History Date Description Act Insp Comments ps,,v *,^'-" •:,;•'- . - -'^•i*: . .^-M^" •: :>,. ,\^H NOTICECITY OF CARLSBAD (760) 602-2700 BUILDING DEPARTMENT 1635 FARADAY AVENUE DATE X ^ ' —*~ f CS TIME LOCATION PERMIT NO. S/9&J ^7 )f/ s ^ / £ ^- c^^ XX FOR INSPECTION CALL (760) 602-2725. RE-INSPECTION FEE DUE? FOR FURTHER INFORMATION, CONTACT YES PHONE CODE ENFORCEMENT OFFICER EsGil Corporation In Partners Hip with government for (Buiftfing Safety DATE: 6/11/1O JURISDICTION: City of Carlsbad PLAN CHECK NO.: 10-0721 PROJECT ADDRESS: 2718 Gateway Rd PROJECT NAME: Flooring America - TI CLAEgUQANT OPO^TREVIEWER Q FILE SET. II The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. AJ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person Q_^ XI REMARKS: The person responsible for the preoaiation of the plans shall sign all sheets and the engineer shall sign the S-1 sheet. ApplicanVft/add note in red on sheet TI-5 to City held sets. 0 By: Doug Moody EsGil Corporationn GA n EJ n PC Enclosures: 6/4/10 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 4 (858) 560-1468 4 Fax (858) 560-1576 EsGil Corporation , In Partnership witA government for (Building Safety DATE: 5/6/1O OAERLJ£ANT JURISDICTION: City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 10-0721 SET: I PROJECT ADDRESS: 2718 Gateway Rd PROJECT NAME: Flooring America - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. X3 The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list js enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Roberts & Bennett / Tina Bennett 1010 University Ave Suite C203, San Diego, CA 92103 Esgil Corporation staff did not advise the applicant that the plan check has been completed. XI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Tina Bennett Telephoned 619-297-1011 ex107 Date contacted: 6/ l//lfynjj^> Fax #: 619-297-3832 Mail * Telephone Fax^/ In Person REMARKS: By: Doug Moody Enclosures: EsGil Corporation D GA D EJ D PC 4/29/10 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 ^ Fax (858) 560-1576 City of Carlsbad 1O-O721 5/6/10 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 10-0721 OCCUPANCY: M TYPE OF CONSTRUCTION: VB ALLOWABLE FLOOR AREA: SPRINKLERS?: No REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 4/27/10 DATE INITIAL PLAN REVIEW COMPLETED: 5/6/10 JURISDICTION: City of Carlsbad USE: Retail ACTUAL AREA: 7168sf STORIES: 1 HEIGHT: OCCUPANT LOAD: 158 DATE PLANS RECEIVED BY ESGIL CORPORATION: 4/29/10 PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2007 CBC, which adopts the 2006 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2006 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad 1O-0721 5/6/10 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the 600# rooftop air handler units. Include all calculations and finding on the plans. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. 2. Please review the requirements, revise the plans appropriately and imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans. 3. Please revise the interior partition details the wall framing member are undersized. 4. Provide a section view of the new soffits. Show: a) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". b) Method of attaching top to the structure and lateral bracing. c) Wall sheathing material and details of attachment (size and spacing of fasteners). d) Show height of the soffit from floor, soffit to roof framing or floor framing. 5. Please clarify the reflective ceiling plans to show all area open to roof structure. 6. Please have the Document Author sign the Statement of Compliance of the PERF-1-C energy document. 7. Please revise the wall section to show the insulation in the demising wall at the warehouse to be R-13 per the mandatory measures. City of Carlsbad 1O-0721 5/6/1O 8. Please clarify the plans to show the R-19 insulation in the roof assembly per the PERF-1C documents. 9. Please revise the electrical plans to show all lighting fixtures not controlled by occupancy sensor to be controlled by a complete building shut-off and indicate that equipment in the LTG-1C forms (part 3 of 4, 4 of 4). 10. Please revise the lighting fixture schedule to show the track lighting current limiters shown in the LTG-5C form. Indicate on the lighting plans the location and VA of each of the current limiters. 11. Please revise the plans to show a disabled accessible transaction counter located at a section of the main counter that is at least 36" long and no more than 28" to 34" high (flip-up or folding counters are only permitted in existing buildings when a finding of unreasonable hardship is found by the building Official). Section 1122B.5. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad 10-O721 5/6/10 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 10-0721 PREPARED BY: Doug Moody DATE: 5/6/10 BUILDING ADDRESS: 2718 Gateway Rd BUILDING OCCUPANCY: M TYPE OF CONSTRUCTION: VB BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) 7168 cb Valuation Multiplier 34.37 By Ordinance Reg. Mod. VALUE ($) 246,364 246,364 Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: Repetitive FeeRepeats Complete Review D Other i—i Hourly EsGil Fee Structural Only Hr. $1,181.01 $767.66 $661.37 Comments: Sheet 1 of 1 macvalue.doc + City of Carlsbad Public Works Engineering BUILDING PLANCHECK CHECKLIST BUILDI PROJECT DESCRIPTION: ASSESSOR'S PARCEL NUMBER: ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. D A Right-of-Way permit is required prior to construction of the following improvements: DENIAL the attached report of deficiencies marked Make necessary corrections to plans or specifications for compliance with applicable codes and standards. -Submit corrected plans and/or specifications to this office for review. By: By: Date: Date: By: FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: Datei ATTACHMENTS D Dedication Application/Checklist D Encina Wastewater Screening Survey D Encroachment Application/Checklist HI Final Map (Reference) D Grading Plan Application/Checklist D Improvement Application/Checklist D Neighborhood Improvement Agreement D Right-of-Way Permit Submittal Checklist and Information Sheet Q Storm Water Compliance Forms [] Other ENGINEERING DEPARTMENT CONTACT PERSON Name: Linda Ontiveros City of Carlsbad Address: 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: (760) 602-2773 Fax: (760) 602-1052 Email: Linda.Ontivero8@carlsbadca.gov CFD INFORMATION Reference No(s): Lot No.:t±_ Recordation: Subdivision/Tract: 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-2720 • FAX (760) 602-8562 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD SITE PLAN n 1- Provide a fully dimensioned site plan drawn to scale. Show: A. North Arrow F. Right-of-Way Width & Adjacent Streets B. Existing & Proposed Structures G Driveway widths C. Existing Street Improvements H. Existing or proposed sewer lateral D. Property Lines (show all dimensions) I. Existing or proposed water service E. Easements J. Existing or proposed irrigation service K. Submit on signed/approved plans DWG No. _ n 2. Show on site plan: A. Drainage Patterns 1 . Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography C. Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. D. Sewer and water laterals should not be located within proposed driveways, per standards. D D 3. Include on title sheet: A. Site address B. Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. Show all existing use of SF and new proposed use of SF. Example: Tenant Improvement for 3500 SF of warehouse to 3500 SF of office. EXISTING PERMIT NUMBER DESCRIPTIONES m Rev. 2/02/09 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD DISCRETIONARY APPROVAL COMPLIANCE CD O [U 4a. Project does not comply with the following Engineering Conditions of approval for Project No. D 4b. All conditions are in compliance. Date: DEDICATION REQUIREMENTS C3 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 17.000 . pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 Yz x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 82.000 . pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: f"~| n 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $441 so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD IMPROVEMENT REQUIREMENTS continued D D D 6c. Enclosed please find your Neighborhood Improvement Agreement (NIA). Please return agreement signed and notarized to the Engineering Department. Completed by: Date: 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS he conditions that invoke the need for a grading permit are found in Section 15.16.010 of the Municipal Code. D 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill import, export). This information must be included on the plans. n 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: D /D LTl 7c. Graded Pad Certification required. (Note: Pad certification may be required even / if a grading permit is not required.) JO CH D 7d .No Grading Permit required. D CD D 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS D D D RIGHT-OF-WAY PERMIT 8. A Right-of-Way permit is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. To see current requirements, visit our website: www.carlsbadca.gov/development-forms Right-of-Way permit required for: Rev. 2/1X009 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD INDUSTRIAL WASTE PERMIT D EH D 9- If your facility is located in the City of Carlsbad sewer service area, you must complete the attached Industrial Wastewater Discharge Permit Screening Survey. Fax or mail to Encina Wastewater Authority, 6200 Avenida Encinas, Carlsbad, CA 92011, (760) 438-3941, Fax (760) 476-9852. STORM WATER REQUIREMENTS Construction Compliance D C] D 10a. Project Threat Assessment Form complete. D CU D 10b. Enclosed Project Threat Assessment Form incorrectly completed. Please make the corrections, re-sign a new form and resubmit with next submittal. D CU D 10c. Requires Tier 1 Storm Water Pollution Prevention Plan Please complete attached form and return (SW ) D CU D 10d. Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2 SWPPP payment of processing fee, and review by City f Post-Development (SUSMP) Compliance D CU D 10e. Storm Water Standards Questionnaire complete. CU f~1 CU 10f. Stormwater Standards Questionnaire incorrectly completed. Please make the corrections, re-sign the questionnaire and resubmit with next submittal. D CD D 10g. Project is subject to Standard Stormwater Requirements. See City Standard Urban Stormwater Management Plan (SUSMP) for reference. D CU D 10h. Disconnect Discharges per SUSMP. Do not connect runoff from impervious surfaces to storm drains without first discharging water over landscape areas first. See SUSMP. D CD D 10i. Minimize use of impervious surfaces per SUSMP. Redesign to reduce the excessive use of impervious area (pavement) on project. Use a balanced design of pervious surfaces (landscape area, planters, etc.) and impervious surfaces. See SUSMP. D D D 1 Qj. Trash Storage areas must be designed per City Standards (GS-16) to avoid contact with storm runoff. D D D 10k. Project is subject to Priority Development Project Requirements D D D 101- Prepare and submit of a Storm Water Management Plan (SWMP). Requires payment of processing fee and review by City. D D D 10m. Project does not comply with recommendations of the approved SWMP. Redesign to comply and resubmit. BUILDING PLANCHECK CHECKLIST 2ND 3RD DEVELOPMENT FEES d 11. Q Required fees have been entered Qi More information needed Q No fees required WATER METER REVIEW 12a. Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for e life of the meter, the City will not accurately bill the owner for the water used. All single family dwelling units receive "standard" 1" service with 5/8" meter. All residential units that need to be fire sprinkled receive a 1" meter. See Carlsbad Municipal Code Section 17.04.230 for Automatic fire extinguishing systems criteria. If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. Maximum service and meter size is a 2" service with a 2" meter. NOTE: Upon declaration of Drought Response Level 3 condition, no new water service shall be provided and no new temporary meters or permanent meters shall be provided. See Ordinance 44 for more information. D 12b. Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: • If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service should look like: STA1+00 Install 2" service and 1.5: meter (estimated 100 gpm) BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD WATER METER REVIEW continued O IH D 12b. Irrigation Use (continued) Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water service boundary, the City is in the process of switching these irrigation services/meters to a new recycled water line G 12c. Irrigation Use (where recycled water is available) Recycled water meters are sized the same as the irrigation meter above. • If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, the City of Carlsbad cannot guarantee the refund. The applicant must deal with the SDCWA for this. Q D Q 13. Additional Comments: D Address: ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET Estimate based on unconfirmed information from applicant. Calculation based on building plancheck plan submittal. £f)Bldg. Permit No. Prepared by :__!>£_____ Date: S/(2-f\O Checked by: T Date: Types of Use: Types of Use: EDU CALCULA TIONS: List types and square footages for all uses. Types of Use: OFpl£{? Sq. Ft./Units. I^£Q2J , EDU's: Types of Use :3jOV^NCX^\A Sq. Ft./Units: ^Ty H"( oj^i EDU's: I ^5x " Sq. Ft./Units: I EDU's: Sq. Ft./Units: EDU's: 4D7 CALCULATIONS: List types and square footages for all uses. Types of Use: Types of Use. Types of Use: Types of Use: Sq. Ft./Units: Sq. Ft./Units: Sq. Ft./Units: Sq. Ft./Units: 3V FEES REQUIRED: WITHIN CFD: D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) D NO D 1 . PARK-IN-LIEU FEE: NW QUADRANT NE QUADRANT SE QUADRANT SW QUADRANT FEE/UNIT: _ _ X NO. UNITS: « $ _ __ IMPACT FEE ADT-s/UNITS:FEE/APT: D 3. BRIDGE AND THOROUGHFARE FEE (DIST. #1 _ DIST. #2 ADT's/UNITS: _ X FEE/APT: DIST. #3 =* D 4. FACILITIES MANAGEMENT FEE . UNIT/SO.FT.: j. SEWER FEE EDU's: ^-^^ ZONE: X FEE/SQ.FT./UNIT: SO9. BENEFIT AREA: EDU's: D 6. DRAINAGE FEES PLDA_ ACRES: X FEE/EDU:. HIGH X FEE/AC: /LOW_ . POTABLE WATER FEES UN»TS CODE CONNECTION FEE METER FEE SDCWA FEE F \FARMER\KATHY\IMASTERS\FEE CALCUUTION WORKSHEET.doc2008.doc Rev. 7/14/00 t.sco 1.10 ,-fo (0 ADT x ^CARLSBAD CITY OF STORM WATER COMPLIANCE ASSESSMENT B-24 Development Services Building Department 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov am applying to tJ^City of Carlsbad for the following type(s) of construction permit: JZ1 Building Permit Q Right-of-Way Permit Q My project is categorically EXEMPT from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it only requires issuance of one or more of the following permit types: Electrical Fire Additional Fire Alarm Fixed Systems Mechanical Mobile Home Plumbing Patio/Deck Re-Roofing Sign Spa-Factory Sprinkler Water Discharge Project Storm Water Threat Assessment Criteria* No ThreatAssessment Criteria \^/My project qualifies as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it meets the "no threat" assessment criteria on the City's Project Threat Assessment Worksheet for Determination of Construction SWPPP Tier Level. My project does not meet any of the High, Moderate or Low Threat criteria described below. Tier 1 - Low Threat Assessment Criteria Q My project does not meet any of the Significant or Moderate Threat criteria, is not an exempt permit type (See list above) and the project meets one or more of the following criteria: • Results in some soil disturbance; and/or • Includes outdoor construction activities (such as roofing, saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling). Tier 2 - Moderate Threat Assessment Criteria Q My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria: • Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code); or, • Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria: • Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or • Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or • Disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse, and/or • Construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30). Tier 3 - Significant Threat Assessment Criteria Q My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or Q My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, refueling and maintenance areas: or, Q My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s). / certify to the best of my knowledge that the above checked statements are true and correct. I understand and acknowledge that even though this project does not require preparation of a construction SWPP, I must still adhere to, and at all times during construction activities for the permit type(s) check above comply with the storm water best management practices pursuant to Title 15 of the Carlsbad Municipal Code and to City Standards. *The City Engineer may authorize minor variances from the Storm Water Threat Assessment Criteria in special circumstances where it can be shown that a lesser or higher Construction SWPPP Tier level is warranted. Project Address:Assessor Parcel No. Owner/Owners Authorized Agent Name: Owner/Owners AutnortefeiJ Agent Signature: City/Concurrence: {/YES QUO ^45 TOP /0s ay B-24 Page 1 of 1 Rev.03/09 o o 1/1o oFT .s s s03 CO COQ Q Q PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB10-0721 Address 2718 Gateway Rd Planner Chris Sexton Phone (760) 602-4624 APN: 213-263-15 Type of Project & Use: JJ, Net Project Density:N/A DU/AC Zoning: P-C General Plan: PI Facilities Management Zone: CFD (in/out) #_Date of participation: Remaining net dev acres:_ Circle One (For non-residential development: Type of land used created by this permit: 00 eg co Q. Q. n D D DD D D Legend: [x] Item Complete D Item Incomplete - Needs your action Environmental Review Required: YES Q NO Q TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES Q NO Q TYPE APPROVAL/RESO. NO. DATE . PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES d NO Q CA Coastal Commission Authority? YES D NO Q If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Habitat Management Plan Data Entry Completed? YES D NO Q If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) Inclusionary Housing Fee required: YES D NO n (Effective date of Inclusionary Housing Ordinance - May 21,1993.) Data Entry Completed? YES D NO D (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev 4/08 Site Plan: Kl D D Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. Policy 44 - Neighborhood Architectural Design Guidelines Kl D D 1- Applicability: YES D NO D D D D 2. Project complies: YES D NOJH D D D Zoning: 1. Setbacks: Front: Interior Side: Street Side: Rear: Top of slope: Required. Required Required Required. Required 2, Accessory structure setbacks: Front: Interior Side: Street Side: Rear: Structure separation: 3, Lot Coverage:Required. Shown. Shown Shown Shown Shown Required Required Required Required Required Shown Shown Shown Shown Shown Shown 4. Height:Required Shown Spaces Required.Shown5. Parking: (breakdown by uses for commercial and industrial projects required) Office Required Shown Warehouse Required Required Shown Wholesale Required Required Shown Additional Comments 1) Please show the breakdown of parking for the use. See attached handout. Will there be any new roof mounted equipment and if so how will it be screened? Please see attached handout. 6-3-10 1) Please show the breakdown of parking for the use. 2) The exhibit showing roof-top mechanical equipment screened by parapet needs to be incorporated into building set on 24'x36' size paper not as an attachment. 3) Additionally, please state on the plans the use of the business. Per the Carlsbad Municipal Code, the P-M zone does not allow any type of retail in nature. The P-M zone allows only professional office, wholesale, manufacturing and warehouse. 6-30-10 Please show the breakdown of the parking on sheet "TI-1" OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTE H:\ADMIN\Template\Building Plancheck Review Checklist.doc Rev 4/08 ACOR& CERTIFICATE OF LIABILITY INSURANCE wSEJ* PRODUCER Snapp & Associates Insurance Services, Inc. 438 Caroino del Rio So. #112 San Diego CA 92108 Phone:619-908-3100 Fax:619-908-3110 INSURED S.P. White Construction, Inc.Dba: White Construction5937 Darwin Court, Suite 100Carlsbad CA. 92008 DATE(MMIDD/YYYY) 01/05/10 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATIOI\ ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATEHOLDER, THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW INSURERS AFFORDING COVERAGE INSURER A: Colony Insurance Co, INSURERS: Hartford Fire Insurance Co. INSURER c: RSU± Indemnity Company INSURER D: Everest national Insurance Co. INSURER E . . NAIC# 19682 COVERAGES MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE UMTS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSK LTR A B C D OTJT NSRD TYPE OF INSURANCE GENERAL LIABILITY X COMMERCIAL GENERAL LIABILITY | CLAIMS MADE | X | OCCUR GEN'L AGGREGATE LIMIT APPLIES PER: X~| POLICY | | SECT | | LOG AUTOMOBILE LIABILITY ANY AUTO ALL OWNED AUTOS X SCHEDULED AUTOS X HIRED AUTOS X NON-OWNED AUTOS GARAGE LIABILITY ~H ANY AUTO EXCESS/UMBRELLA LIABILITY IE"] OCCUR . | | CLAIMS MADE " 1 DEDUCTIBLE E~] RETENTION $.''.. WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNER/EXECUti VEOFFICER/MEMBER EXCLUDED? If yes, describe under SPECIAL PROVISIONS below OTHER POLICY NUMBER | MrlfliSSrlSfvYf 1 ^TC^WDWYY) N I 61.950965 72UECKR7873 NHA224736 7600000885101 10/01/09 10/01/09 10/01/09 01/01/10 10/01/10 10/01/10 10/01/10 01/01/11 LIMITS EACH OCCURRENCE PREMISES (Ea occurence) MED EXP (Any one person) PERSONAL & ADV INJURY GENERAL AGGREGATE PRODUCTS - COMP/OP AGG COMBINED SINGLE LIMIT (Ea accident) BODILY INJURY (Per person) BODILY INJURY(Per accident) PROPERTY DAMAGE(Per accident) AUTO ONLY - EA ACCIDENT OTHER THANAUTO ONLY: EAACC AGG EACH OCCURRENCE AGGREGATE X TORY LIMITS" [OTH-1 6R EL. EACH ACCIDENT EL. DISEASE - EA EMPLOYEE E.L. DISEASE - POLICY LIMIT sl, 000, 000 $100,000 $5,000 $1,000,000 S2, 000, 000 $2,000,000 $ 1000000 $ s $ s s s £10,000,000 s 10, 000, 000 $ $ s * 1000000 $ 1000000 $ 1000000 Re: Operations of the named insured subject to the terms and conditions of the policy. 10* days notice of cancellation in the event of nonpayment of prexniuitL , CERTIFICATE HOLDER CANCELLATION CITlfOPC City of Carlsbad Attn: Building Dept. 1635 Faraday Ave Carlsbad CA 92008-7314 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL 30* DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO DO SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR REPRESENTATIVES., ^p^^pM^Q^-. ACORD 25 (2001/08) • © AGO RD CORPORATION 1988 Structural Calculations Flooring America T.I. 2718 Gateway Road Carlsbad, CA 92008 Prepared for: Roberts & Bennett 1010 University Avenue, Suite 0203 San Diego, CA 92103 Prepared by: HOPE ENGINEERING, INC. 1301 Third Avenue, Suite 300 San Diego, CA 92101 May 23,2010 HE Project*: 210077.00 GEMOO-721 ! 1301 Third Avenue Suite 300 San Diego, CA 82101 TELV (619) 232-4673FAX: (619) 236-4675lnfo@hopeengineering.com JOB Ho SHEET NO. CALCULATED BY_ CHECKED BY _OF ~DATE_ "DATE" Seismic Design Base Shear: Equivalent Lateral Force Procedure I Determine value of the Seismic Design Base Shear, V. Based on ASCE 7-05. Requirements for Seismic Design Category A are not considered. Step 11nput Data Variables determined by building configuration 1 Occupancy Category per Table 1 -1 I =1.00 Occupancy importance factor per Table 11.5-1 C, = 0.020 Building Period parameter per Tabte 12.8-2 x - 0.75 Building Period parameter per Tabte 12.8-2 R = 4.00 Response Modif.Coeff. per Table 12.2-1 hn = 24.00 Height above base to the uppermost level in the main portion of the building, (ft) Variables determined by site and location D Site Class per Table 20.3-1 TI =8 Long-period Transition per Figure 22 1.251 Spectral Accel, for short periods per Figure 22 0.472 Spectral Accel, for 1 -sec. period per Figure 22 1.000 Site Coefficient per Table 11. 4-1 1 .528 Site Coefficient per Table 1 1 .4-2 S,* Si* F,* Fv* •Use USGS website to get precise values: Step 1 Output Data Approximate fundamental period, T, (sec.) per Section 12.8.2.1 T, = C, (rgx = 0.217 (Equation 12.8-7) Design spectral response acceleration coefficients per Sections 11.4.3 and 11.4.4 (Equation 11.4-1 and Equation 11.4-3) (Equation 11.4-2 and Equation 11.4-4) (Section 11.4.5) (Section 11.4.5) SMS = FjS, = 1.251 SDS " &3)&us = 0.834 SKH = FvSi = 0.721 S01 » (2/3)8^ = 0.481 Response Spectrum Transition Periods (sec.) per Section 11.6.5 TO = 0.2(SD1/Sos) = 0.115 Ts = SOI/SDS = 0.577 0.8 T. - 0.461 Step 2 Input Data Variables determined by Sections 11.6 and 12.8.2 D Seismic Design Category per Section 11.6 Cu " 1.4 Period upper limit coeff. per Table 12.8-1 Step 2 Output Data Upper limit fundamental period for base shear determination, T (sec.) per Section 12.8.2 T = T, x Cu. 0.304 Seismic Base Shear, V per ASCE Section 12.8.1 C.mln ™ • ft>rrsrt; c.m =• (R/l) 0.044 SDS I O.SS, (R/0 So, ForT> TL: SD1TL T2(R/I) 0.209 0.037 n/a 0.396 n/a C.W C.W C,W 0.209 W 0.037 W W (Section 12.8.2) (Equation 12.8-2 and Equation 12.8-1) (Equation 12.8-5 and Equation 12.8-1) (Equation 12.8-6 and Equation 12.8-1) V * C.W = 0.396 W (Equation 12.8-3 and Equation 12.8-1) C,W W (Equation 12.8-4 and Equation 12.8-1) IWROJECTSQ010O10077.00 Flooring Antrim TIM Cental Rlw\03 CDcASpratdihMMSd ids 2006 IBCJte 1301 Third Avenue JOB tlt> ffTf.O HUMi ENGINEERING «=n Oteg«, HA IJ21O1 SsMttT NO. _ ™ irioiJiSLjim CALCULATED BY FAX: (819) 235-4675 CHECKED BY info@hopeengineertng.com OF DATE DATE Seismic Lateral Force on Non-Structural Elements and Components„ »._ Determine value of Fp (relative to Wp). Based on ASCE 7-05. Requirements for Seismic Design Category A are not considered. Input Data Variables determined by Sections 11.4.4 and 13.1.3 SDS = °-834 Spectral acceleration for short period per Section 11.4.4 IP =1.0 Component importance factor per Section 13.1.3 Output Data Strength level seismic design force per Section 13.3 and Tables 13.5-1 and 13.6-1 (Equation 13.3-3) (Equation 13.3-2) 0.3 SDS Ip Wp = 0.25 Wp Pp(n«o= 1-6 SDS Ip Wp = 1.33 Wp 0.4 ap SDS Wp (Equation 13.3-1) I coefficient from table below WD Strength level values of Fp (relative to Wp) z h 1.00 0.95 0.90 0.85 0.80 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 3j, : 1.25 Rp : 1.00 1.25 1.21 1.17 1.13 1.08 1.04 1.00 0.96 0.92 0.88 0.83 0.79 0.75 0.71 0.67 0.63 0.58 0.54 0.50 0.46 0.42 1.00 1.50 0.67 0.64 0.62 0.60 0.58 0.56 0.53 0.51 0.49 0.47 0.44 0.42 0.40 0.38 0.36 0.33 0.31 0.29 0.27 0.25 0.25 2.50 1.50 1.33 1.33 1.33 1.33 1.33 1.33 1.33 1.28 1.22 1.17 1.11 1.06 1.00 0.95 0.89 0.83 0.78 0.72 0.67 0.61 0.56 2.50 2.00 1.25 1.21 1.17 1.13 1.08 1.04 1.00 0.96 0.92 0.88 0.83 0.79 0.75 0.71 0.67 0.63 0.58 0.54 0.50 0.46 0.42 1.00 2.50 0.40 0.39 0.37 0.36 0.35 0.33 0.32 0.31 0.29 0.28 0.27 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 2.50 2.50 1.00 0.97 0.93 0.90 0.87 0.83 0.80 0.77 0.73 0.70 0.67 0.63 0.60 0.57 0.53 0.50 0.47 0.43 0.40 0.37 0.33 2.50 3.00 0.83 0.81 0.78 0.75 0.72 0.70 0.67 0.64 0.61 0.58 0.56 0.53 0.50 0.47 0.44 0.42 0.39 0.36 0.33 0.31 0.28 1.00 3.50 0.29 0.28 0.27 0.26 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 2.50 3.50 0.71 0.69 0.67 0.64 0.62 0.60 0.57 0.55 0.52 0.50 0.48 0.45 0.43 0.41 0.38 0.36 0.33 0.31 0.29 0.26 0.25 2.50 0.00 0.00 0.00 6.00 0.00 0.00 0.00 0.42 0.40 0.39 0.38 0.36 0.35 0.33 0.32 0.31 0.29 0.28 0.26 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 l:\PROJECTS\2010\210077.00 Flooring America TM Central FUesUB CdcriSpreadsheeMSeismlc Loads 2006 IBCJds PHYSICAL DATA - UNIT 50VT UNIT SIZE NOMINAL CAPACITY (ton) (kg)COMPRESSOR QUANTITY TYPE REFRIGERANT Relrlgerant (H-410A) Quantity (ID) Quantity (kg) MtltHING DEVICE ID ORIFICE OD (In.) (mm) OUTDOOR COIL Rows- Fins/In, face area (aq.lt) OUTDOOR PAN Nominal Airflow Diameter Motor HP (RPM) INDOOR COIL Rows... Fins/In, face area (sq.fL) INDOOR BLOWER Nominal Cooling Airflow (CFM) Size (In.) (mm) Cutout Rcs0t (Auto) LOSS-OF-CHARGE/LOW-PRESSURE SWITCH (UquWUneXpslg) Cutout Reset (Auto) KCI URN-AIR FILTERS"! throwaway (In.) (mm) 5OVT-A24 2 336 152 50VT-A30 2.5 346 157 50VT-A38 3 406 185 50VT— A42 3.5 204 50VT-A48 50VT-A60 5 226 1 SCROLL COMPRESSOR H-410A 3.S 4.3 0.032(2) .81 2...21 13.6 2500 1/8(825) 3...17 3.7 800 10x10 254x254 1/2 12.0 5.5 0.038(2} .97 2...21 15.4 2600 1/8(825) 3...17 3.7 1000 10x10 254x254 1/2 9.0 4.1 0.040(2) 1.02 2...21 13.6 3000 1/4(1100) 3...17 4.7 1200 11x10 279x254 3/4 14.0 6.4 TXV 0.038 (Lett OD COil) 0.040 (Right OD Coil) .97/102 2...21 19.4 3500 1/8 (825) 3...17 4.7 1400 11x10 279x254 3/4 17.0 7.7 0.040 (2) 1.02 2...21 19.4 3500 1/4(1100) 3...17 5.7 1600 11x10 279x254 1.0 16.0 7.3 0.049(2) 1.24 2...21 23.3 3800 1/3(1100) 4...17 5.7 1750 11x10 279x254 1.0 650±15 420±25 20±5 45±10 2Q±5 45x10 20x20x1 508x508x25 20x24x1 508x610x25 24x30x1 610x762x25 24x36x1 610x914x25 'Required filter sizes shown are based on the larger of the AHI (Air conditioning and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 ft/minute for throwaway type or 450 ft/minute for high-capacity type. Air filter pressure drop for non-standard filters must not exceed 0.08 IN. W.C. t If using accessory filter rack refer to the filter rack installation instructions for correct filter size and quantity, t For 460 vott units, add 14 Ib (6.4 kg) to the weight A-WEIGHTED SOUND POWER LEVEL (dBA) MODEL 50VT-A 24-— —301 30 sol/sol 36 301/501/601 42 301/501/601 48 301/501/601 60 301/501/601 5»IANUARD RATING (dBA) 74 72 78 75 78 79 TYPICAL OCTAVE BAND SPECTRUM (dBA) (without tone adjustment) 125 67.0 61 .5 62.0 62.5 70.5 69.O 250 65.5 62.5 69.0 62,5 69.5 69.O 500 68.5 66.0 72.5 68.5 71.0 71.5 1000 68.0 66.0 73.0 70.0 72.5 74.0 2000 63.5 63.0 70.5 67.0 69.5 72.0 4000 59.5 57.5 67.5 62.0 66.0 67.5 8000 53.5 50.5 62.0 58.5 59.5 59.5 NOTE: Tested in accordance with ARI Standard 270 (not listed in ARI). 8U60V 09-9CV-JAOS -JINfl HOPE ENGINEERING 1301 Third Ave., Ste. 300 San Diego, CA 92101 SHEET NO.OF CALCULATED BY CHECKED BY SCALE DATE JOB.on~i. o HOPE ENGINEERING 1301 Third Ave., Ste. 300 San Diego, CA 92101 SHEET NO CALCULATED HV CHECKED BY SCALE OF_ DATE. DATE. Maximum Span Calculator for Joists & Rafters Page 1 of 1 Maximum Span Calculator council f°r Wood Joists & Rafters www.awc.ora Species ||| Douglas Fir-Larch Jig Size! 2x8 H GradeJ No. 2 • || Member Type|| Rafters (Roof Live-Load) j|g Deflection Limit! L/360 fit Spacing (in)|[ 24 Ijf Exterior Exposure Live Load (psf) Dead Load (psf) Wet service conditions? Incised lumber? • "® tJL^Ill [20 ijj !10 ij| rj The Maximum Horizontal Span is: 13 ft. 8 in. with a minimum bearing length of 0.65 in. required at each end of the member. Property Species Grade Size Modulus of Elasticity (E) Bending Strength (Fb) Bearing Strength (Fc ) Shear Strength (Fv) Value Douglas Fir-Larch No. 2 2x8 1440000 psi 1552.5 psi 418.75 psi 218.25 psi _n I 1 While every effort has been made to insure the accuracy of the information presented, and special effort has been made to assure that the information reflects the state-of-the-art, neither the American Forest & Paper Association nor its members assume any responsibility for any particular design prepared from this Online Span Calculator. Those using this Online Span Calculator assume all liability from its use. Attention mobile device users. Note that the Online Span Calculator was recently reformatted to allow easier use on mobile devices. We are interested in user input regarding the new format and the use of the Online Span Calculator on mobile devices. Send comments to awcinfo@afandpa.org. http://www.awc.org/calculators/span/calc/ti^ 5/19/2010 HOPE ENGINEERING 1301 Third Ave., Ste. 300 San Diego, CA 92101 JOB SHEET NO.. CALCULATED BY. CHECKED BY SCALE OF DATE. DATE. BUILDING ENERGY ANALYSIS REPORT PROJECT: FLOORING AMERICA By Picket Fence Design 2718 GATEWAY ROAD CARLSBAD, CA 92008 Project Designer: BTA ENGINEERS, INC. 5125 CONVOY ST., STE 212 SAN DIEGO, CA 92111 858-715-6601 Report Prepared by: Tom Q. Le P.E. BTA Engineers, Inc. 5125 Convoy St.,STE 212 San Diego, CA92111 858-715-6601 Job Number: 10.38.00 Date: 4/23/2010 The Energy-Pro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC -www.energysofl.com. EnergyPro 5.0 by EnergySaft User Number: 7231 RunCode: 2010-04-23710:06:5 ID: 10.38.00 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form ENV-MM Envelope Mandatory Measures 20 Form MECH-MM Mechanical Mandatory Measures 21 EnergyPro 5.0 by EnergySoft Job Number: ID: 10.38.00 User Number: 7231 PERFORMANCE CERTIFICATE OF COMPLIANCE (Parti of 3) PERF-1C Project Name FLOORING AMERICA By Picket Fence Design Date 4/23/2010 Project Address 2718 GATEWAY ROAD CARLSBAD Climate Zone CA Climate Zone 07 Total Cond. Floor Area 6,854 Addition Floor Area n/a GENERAL INFORMATION Building Type:0 Nonresidential D D Relocatable - indicate D High-Rise Residential D specific climate zone D Hotel/Motel Guest Room all climates Phase of Construction: 12 New Construction D Addition D Alteration STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Name Tom Q. Le P.E.Signature Company BTA EngineerSi lnc Date 4/23/2010 Address 5125 Convoy St.,STE 212 Phone 858-715-B601 City/State/Zip $an Diego, CA 92111 The Principal Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the energy efficiency requirements contained in sections 110,116 through 118, and 140 through 149 of Title 24, Part 6. Please check one: ENV. LTG. MECH. Ef D D D I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described jis exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. * Principal Envelope Designer Name Signature Company BTA ENGINEERS, INC. Address 5725 CONVOY ST., STB 212 City/State/Zip SAN D/£SO_ CA92111 Principal Mechanical Designer Name TOMQ. LEP.E.Signature Company BTA ENGINEERS, INC. Address 5125CO/vVOYSr., STE212 City/State/Zip CA 921 1 1 Phone 858.715_B601 Principal Lighting Designer Name Signature Company Lighting Compliance Not In The Scope Of This Submittal Date Address License # City/State/Zip Phone INSTRUCTIONS TO APPLICANT COMPLIANCE & WORKSHEETS (check box if worksheets are included) El ENV-1C Certificate of Compliance. Required on plans. El MECH-1C Certificate of Compliance. Required on plans. D LTG-1C Certificate of Compliance. Required on plans. El MECH-2C AirAA/ater Side/Service Hot Water & Pool Requirements. D • LTG-2C Lighting Controls Credit Worksheet. El MECH-3C Mechanical Ventilation and Reheat. G LTG-3C Indoor Lighting Power Allowance. El MECH-5C Mechanical Equipment Details. EnergyPro 5.0 by EnergySoft User Number: 7231 RunCode: 2010-04-23710:08:52 ID: 10.38.00 Page 3 of 21 PERFORMANCE CERTIFICATE OF COMPLIANCE (Part 2 of 3) PERF-1C Project Name FLOORING AMERICA By Picket Fence Design Date 4/23/2010 ANNUAL TDV ENERGY USE SUMMARY (kBtu/sqft-yr) Energy Component Space Heating Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting Receptacle Process Process Lighting TOTALS Standard Design 8.38 67.42 19.48 0.00 0.00 5.49 37.15 30.65 0.00 0.00 188.56 Percent better than Standard Proposed Design 1.61 53.25 18.48 0.00 0.00 5.49 37.15 30.65 0.00 0.00 146.63 13.0% Compliance Margin 6.77 14.17 0.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00 21.93 ( 13.0 % excluding process) BUILDING COMPLIES GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of Zones Front Elevation Left Elevation Rear Elevation Right Elevation Tot Roof (S) 180 deg 1 6 4 Orientation (S) (W) (N) (E) al Conditioned Floor Area 8,854 sqft. Unconditioned Floor Area o sqft. Conditioned Footprint Area 6,854 Sqft. Natural Gas Available On Site Yes Gross Area 1,810 1,490 1,053 1,330 5,683 6,854 Standard Lighting Power Density Prescriptive Envelope TDV 0.649 W/sqft. Energy 187,616 sqft. sqft. sqft. sqft. sqft. sqft. Glazing Area Glazing Ratio 384 sqft. 27.2% 384 Sqft. 25.8% o sqft. 0.0% 64 sqft. 4.8 % 832 Sqft. J4.6% o sqft. 0.0% Proposed 0.649 W/sqft. 223, 706 Remarks: EneravPro 5.0 bv EnerovSaft User Number 7231 RunCode: 2010-04-23T10:06:5, ID: 10.38.00 Paae 4 of 21 PERFORMANCE CERTIFICATE OF COMPLIANCE (Part 3 of 3) PERF-1C Project Name FLOORING AMERICA By Picket Fence Design Date 4/23/2010 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area (sqft.) Inst. LPD (W/sf)1 Ctrl. Credits (W/sf)2 Allowed LPD Area (W/sf)3 Tailored (W/sf)4 Proc. Loads (W/sf) OFFICES HP-UNIT OFFICES AREA Office > 250 sqft 1,109 "0.300 SHOWROOM HP-UNITS SHOWROOM Comp Bldg Com & Ind Stora 3,410 "0.600 SHOWROOMAVHOUSE HP SHO WROOM/WAREHOUS,Comp Bldg Com & Ind Stora 2,274 "0.600 SER VER RM AC-UN! TS SERVER ROOM ""Mechanical Equipment Ro 61 *0.700 Notes: 1. Sea LTG-1C (items marked with asterisk, see LTG-1-C by others) 2. See LTG-2C 3. See LTG-3C (by others) 4. See LTG-4C Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justifications, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. ""Denotes an OSHPD Healthcare (I Occupancy) in the list of spaces above, which is NOTregulated by Title 24. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp EnergyPro 5.0 by EnergySoft User Number: 7231 RunCode: 2010-04-23T10.-06.-52 ID: 10.38.00 Page 5 of 21 CERTIFICATE OF COMPLIANCE AND FIELD INSPECTION ENERGY (Part CHECKLIST 1of3) ENV-1C Project Name FLOORING AMERICA By Picket Fence Design Project Address 2778 GATEWAY ROAD CARLSBAD GENERAL INFORMATION Building Type: E Nonresidential Climate Zone 7 Date 4/23/2010 Total Cond. Floor Area Addition Floor Area 6,854 n/a D High-Rise Residential D D Schools (Public School) D Relocatable Public School Q conditioned Spaces Hotel/Motel Guest Room D Unconditioned Spaces Q Skylight Area for Large Enclosed Space £ 8000 ft2 (If checked include the ENV-4C with submittal) Phase of Construction: Q New Construction Approach of Compliance: D Component Front Orientation: N, E, S, W or in Degrees: FIELD INSPECTION ENERGY CHECKL Tag/ID1 Slab Wall Wall Roof Slab Wall Wall Wall 180 deg ST Assembly Frame Type2 Unheated Slabon-Grade Solid Unit Masonry Solid Unit Masonry Metal Framed Rafter Unheated Slab-on-Grade Solid Unit Masonry Solid Unit Masonry Solid Unit Masonry D Addition q Q Overall Envelope D Alteration Unconditioned (file affidavit) fls 1,109 978 116 1,109 3,410 1,426 990 326 SurfaceOrientationN,E,S,W(N) (N) (W) (N) (N) (S) (W) (E)Cavity R-ValueNone None None R-19 None None None None ContinuousR-Valueo.c 13.0 13.0 0.0 0.0 13.0 13.0 13.0 "c U. D m Q D a n 0 0 ccft£5 ConditionStatus5New New New New New New New New % 1^1^^ |?1 q* q; a -Cr, 'H q m ^g; "OT Vfej->- 07 -P~ ;9. ' E$" q 4 D" .q-. q n .q .£ q B- 1 . Indicate the identifying name of the frame type (i.e. Wall -1 , Ceiling- 1 , Roof - 1 , and Floor- 1 ). 2. Indicate type of Assembly Type such as Wood 2x4 or LW CMU 8". For additional other assembly types see Reference Joint Appendix, JA4-1 . 3. If furring is checked refer to ENV-2C Mass and Furring Strips Construction worksheet. 4. Indicate furring R-value when furred wall are being used. 5. Indicate Status of fenestration (New, Existing or Upgrade). 6. Indicate Special Feature on Page 2 of the Inspection Checklist Form below. 7. If Fail, then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. FENESTRATION SURFACE DETAILS Tag/ID1 1 2 3 Fenestration Type2 Window Window Window 8 £ n II 384 384 64 SurfaceOrientationN,E,S,Wm (S) (E) % SD. •5 *t Jat 0.400 0.400 0.400 3in NFRC NFRC NFRC oo 0.420 0.420 0.420 H8in WFRC WFRC WFRC OverhangD D D D D a q D ConditionsStatus4Wew New New rt Jfi q. tl;'> JJT- P, ' q q. q q, , ^ ;%'>&. JPP"*rs3>/SP:r 4i , q cf ,&, " q;' It-f wfr ;;P< %p & • •Q •cf q q 1 . Indicate the identifying name of the frame type (i.e. Window #1 ). 2. Indicate type of construction Type such, Window, Glass Door, Curtain wall, Skylight, or other. 3. Indicate if the efficiency values are from the NFRC Label Certificate or from the CEC Default Values. Enter NFRC or CEC (FC-1 and FC-2). 4. Indicate Status of fenestration (New, Existing or Upgrade). 5. Indicate Special Feature on Page 2 of the Inspection Checklist Form below. 6. If Fail then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. EnergyPfoS.ObyEnergySoft User Number.7231 RunCode: 2010-04-23710:06:52 ID: 10.38.00 Page 6 of 21 CERTIFICATE OF COMPLIANCE (Part 1 AND FIELD INSPECTION ENERGY CHECKLIST of 3) ENV-1C Project Name FLOORING AMERICA By Picket Fence Design Project Address 271 8 GATEWAY ROAD CARLSBAD Climate Zone 7 Date 4/23/2010 Total Cond. Floor Area Addition Floor Area 6,854 n/a GENERAL INFORMATION Building Type: ° Nonresidential B High-Rise Residential B B Schools (Public School) B Ratable Public School 0 Conditioned Spaces Hotel/Motel Guest Room B Unconditioned Spaces B Skylight Area for Large Enclosed Space z 8000 ft2 (If checked include the ENV-4C with submittal) Phase of Construction: B New Construction Approach of Compliance: B Component Front Orientation: N, E, S, W or in Degrees: FIELD INSPECTION ENERGY CHECKL Tag/ID1 Roof Slab Wall Door Roof Slab Wall Wall 180 deg ST Assembly Frame Type2 Metal Framed Rafter Unheated Slab-on-Grade Solid Unit Masonry Opaque Door Metal Framed Rafter Unheated Slab-on-Grade Solid Unit Masonry Solid Unit Masonry B Addition B Alteration 0 Overall Envelope B Unconditioned (file aff davit) t §3 Ztn < 3,410 2,274 816 24 2,274 61 75 100 SurfaceOrientationN,E,S,W(N) (N) (E) (E) (N) (N) (N) (E) EC 5" o 11 R-19 None None None R-19 None None None ContinuousR-Value0.0 0.0 13.0 0.0 0.0 0.0 13.0 13.0 n f 1 B n El n D D 0 21 cc Is3 n ConditionStatus9New New New New New New New New sis tffi ,:Q ; ,p ,p~ .'ft tr n B B- i P-.n' vSUtfti "Pi" .,B", ;<£j B 1 B "B B "B .''JET- '.'$' .B n 1 . Indicate the identifying name of the frame type (i.e. Wall -1 , Ceiling-1 , Roof -1 , and Floor- 1 ). 2. Indicate type of Assembly Type such as Wood 2x4 or LW CMU 8". For additional other assembly types see Reference Joint Appendix, JA4- 1 . 3. If furring is checked refer to ENV-2C Mass and Furring Strips Construction worksheet. 4. Indicate furring R-value when furred wall are being used. 5. Indicate Status of fenestration (New, Existing or Upgrade). 6. Indicate Special Feature on Page 2 of the Inspection Checklist Form below. 7. If Fail, then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. FENESTRATION SURFACE DETAILS Tag/ID1 Fenestration Type2 842 n1 £en <SurfaceOrientation> in J 1 u | S "8 en OO X SEE "8ien Overhangn B P B B B B B ConditionsStatus4OVIJL B P e' JR B B. iX B ' ^ ,ra:" 'M: •&* 'B 'B. :*B VB; B MB ,JP iD" ".,M" ',B vip ' B B 1 . Indicate the identifying name of the frame type (i.e. Window #1 ). 2. Indicate type of construction Type such, Window, Glass Door, Curtain wall, Skylight, or other. 3. Indicate if the efficiency values are from the NFRC Label Certificate or from the CEC Default Values. Enter NFRC or CEC (FC-1 and FC-2). 4. Indicate Status of fenestration (New, Existing or Upgrade). 5. Indicate Special Feature on Page 2 of the Inspection Checklist Form below. 6. If Fail then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. EnergyPro 5.0 by EnergySoft User Number.7231 RunCocie: 2010-04-23710:06:52 ID: 10.38.00 Page 7 of 21 CERTIFICATE OF COMPLIANCE AND FIELD INSPECTION ENERGY (Parti CHECKLIST of 3) ENV-1C Project Name FLOORING AMERICA By Picket Fence Design Project Address 2778 GATEWAY ROAD CARLSBAD GENERAL INFORMATION Building Type: E Nonresiderrtial D Schools (Public School) Q Relocatable Public Schoo D Skylight Area for Large Enclosed Space £ 8000 ft2 (If Climate Zone 7 total Date 4/23/2010 Cond. Floor Area Addition Floor Area 6,854 n/a D High-Rise Residential n El Conditioned Spaces Hotel/Motel Guest Room D Unconditioned Spaces checked include the ENV-4C with submittal) Phase of Constructbn: Q New Construction Approach of Compliance: D Component Front Orientation: N, E, S, W or in Degrees:180 deg D Addition D Alteration EZ1 Overall Envelope D Unconditioned (file affidavit) FIELD INSPECTION ENERGY CHECKLIST Tag/ID' Roof Assembly Frame Type2 Metal Framed Rafter 8 S£* i2 2 61 SurfaceOrientationN,E,S,W(N) EC tl35 R-19 ContinuousR-ValueO.fl € 1 n D n n D D n D ll ConditionStatus6New tnu. fi?; ft;n n a" a m Et r' •IP:/j^,^o¥' *!?, ' &'• * >. ,>H: -I •'a' 0^; p fi -a _.cr *-o Q 1. Indicate the identifying name of the frame type (i.e. Wall -1, Ceiling- 1, Roof -1, and Floor- 1). 2. Indicate type of Assembly Type such as Wood 2x4 or LW CMU 8". For additional other assembly types see Reference Joint Appendix, JA4- 1 . 3. If furring is checked refer to ENV-2C Mass and Furring Strips Construction worksheet. 4. Indicate furring R-value when furred wall are being used. 5. Indicate Status of fenestration (New, Existing or Upgrade). 6. Indicate Special Feature on Page 2 of the Inspection Checklist Form below. 7. If Fail, then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. FENESTRATION SURFACE DETAILS Tag/ID1 Fenestration Type2 8 fa1 SurfaceOrientationN,E,S,W<n •5 4* ii "8 § CO oo S J2.Source3OverhangD D D D D D D O ConditionsStatus41p'" P.; er'p;- Efr 'P' E^ a *,'S" iM It!'A-ir fPn i'i$',' *Bft "tr ,i' n, :;P *" t;p.? •vft-. !rp.' •'ifr. ,'EJ 1 . Indicate the identifying name of the frame type (i.e. Window #1 ). 2. Indicate type of construction Type such, Window, Glass Door, Curtain wall, Skylight, or other. 3. Indicate if the efficiency values are from the NFRC Label Certificate or from the CEC Default Values. Enter NFRC or CEC (FC-1 and FC-2). 4. Indicate Status of fenestration (New, Existing or Upgrade . 5. Indicate Special Feature on Page 2 of the Inspection Checklist Form below. 6. If Fail then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. Energy Pro 5.0 by EnergySofi User Number: 7231 RunCode: 2010-04-23710:06:52 ID: 10.38.00 Page 8 of 21 Project Name FLOORING AMERICA By Picket Fence Design Date 4/23/2010 CERTIFICATE OF COMPLIANCE AND FIELD INSPECTION ENERGY CHECKLIST (Part 2 of 3)ENV-1C ROOFING PRODUCT (COOL ROOFS) (Note if the roofing product is not CRRC certified, this compliance approach cannot be used). Go to Overall Envelope Approach or Performance Approach. CHECK APPLICABLE BOX BELOW IF EXEMPT FROM THE ROOFING PRODUCT "COOL ROOF" REQUIREMENTS:jFJiul1 D Roofing compliance not required in Climate Zones 1 and16 with a Low-Sloped. 2:12 pitch or less. D Roofing compliance not required in Climate Zone 1 with a Steep-Sloped with less than 5 Ib/ft. Greater than 2:12 pitch. Low-sloped Wood framed roofs in Climate Zones 3 and 5 are exempted. Solar reflectance and thermal emittance or SRI that have a U-factor of 0.039 or lower, see Opaque Surface Details roof assembly, Column H of ENV-2C. p. The roof area covered by building integrated photovoltaic panels and building integrated solar thermal panels are exempted. Solar reflectance and thermal emittance or SRI, Roof constructions that have thermal mass over the roof membrane with a weight of at least 25 Ib/ff are exempt from the Cool Roof criteria below. High-rise residential buildings and hotels and motels with low-sloped roofs in Climate Zones 1 through 9, 12 and 16 are exempted from the low-sloped roofing criteria. 1. If Fail then describe on this page of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. CRRC Product ID Number' Roof Slope s 2:12 >2:12 D D D D D D D D D D D D Product Weight < Slb/ft2 a Slb/ft2 D n D n D n n n D n n n Product Type2 Aged Solar Reflectance3 n4 n4 n4 n4 n4 n4 1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Thermal Emmitance SRI5 Special Feature6 D D D D n n Pass n n a a n a Fail7 n D n n D n Rated Product Directory at www.coolroofs .ora/oroducts/search.php 2. Indicate the type of product is being used for the roof top, i.e. single-ply roof, asphalt roof, metal roof, etc. 3. If the Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the Initial Reflectance value from the same directory and use the equation (0.2+0.7(0^31 - 0.2) to obtain a calculated aged value. Where p is the Initial Solar Reflectance from the Cool Roof Rating Council's Rated Product Directory. 4. Check box if the Aged Reflectance is a calculated value using the equation above. 5. The SRI value needs to be calculated from a spreadsheet calculator at http:flwww.6n6rgy.ca.qov/title24/ 6. Indicate Special Feature on Page 2 of the Inspection Checklist Form below. 7. If Fail then describe on this page of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. To apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage recommended by the coatings manufacturer and meet minimum performance requirements listed in §118(i)4. Select the applicable coating: D Aluminum-Pigmented Asphalt Roof Coating D Cement-Based Roof Coating D Other SPECIAL FEATURES INSPECTION CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Discrepancies: EnergyPro 5.0 by EnergySoft User Number: 7231 RunCode: 2010-04-23T10:06:52 ID: 10.38.00 Page 9 of 21 CERTIFICATE OF COMPLIANCE (Part 3 of 3) ENV-1 C AND FIELD INSPECTION ENERGY CHECKLIST Project Name Date FLOORING AMERICA By Picket Fence Design 4/23/2010 Required Acceptance Tests Designer: This form is to be used by the designer and attached to the plans. Listed below is the acceptance test for Envelope Fsnestrations system. The designer is required to check the acceptance tests and list all the fenestration products that require an acceptance test. If all the site-built fenestration of a certain type requires a test, list the different fenestration products and the number of systems. The NA7 Section in the Appendix of the Nonresidential Reference Appendices Manual describes the test. Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Enforcement Agency: Systems Acceptance. Before Occupancy Permit is granted for a newly constructed building or space or whenever new fenestration is installed in the building or space shall be certified as meeting the Acceptance Requirements. The ENV-2A form is not considered a complete form and is not to be accepted by the enforcement agency unless the boxes are checked and/or filled and signed. In addition, a Certificate of Acceptance forms shall be submitted to the enforcement agency that certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of §1 0-1 03(b) of Title 24 Part 6. The field inspector must receive the properly filled out and signed forms before the building can receive final occupancy. A copy of the ENV-2A for each different fenestration product line must be provided to the owner of the building for their records. Test Description Fenestration Products Name or ID Requiring Testing or Verification Window Area of like Products 832 ENV-2A Building Envelope Acceptance Testm n n n n n n n D n n D n n n n n n n n n D n n n n Test Performed By: EnergyPro 5.0 by EnergySoft User Number: 7231 RunCode: 201 0-04-23710:06:52 ID: 10.38.00 Page 10 of 21 CERTIFICATE OF COMPLIANCE and (Part 1 of 4) MECH-1 C FIELD INSPECTION ENERGY CHECKLIST Project Name FLOORING AMERICA By Picket Fence Design Project Address 271 8 GATEWAY ROAD CARLSBAD GENERAL INFORMATION Building Type: ° Nonresidential D Schools (Public School) D Relocatable Public Schoo Phase of Construction: Q New Construction Approach of Compliance: O Component Front Orientation: N, E, S, W or in Degrees: HVAC SYSTEM DETAILS Equipment2 Item or System Tags (i.e.AC-1,RTU-1,HP-1) Equipment Type4: Number of Systems Max Allowed Heating Capacity Minimum Heating Efficiency Max Allowed Cooling Capacity Coolinq Efficiency Duct Location/ R-Value Duct Leakage Testing - If Yes, a MECH-4A must be submitted Economizer Thermostat Fan Control Equipment2 Item or System Tags (i.e.AC-1,RTU-1,HP-1) Equipment Type4: Number of Systems Max Allowed Heating Capacity Minimum Heating Efficiency Max Allowed Cooling Capacity Cooling Efficiency Duct Location/ R-Value Duct Leakage Testing - If Yes, a MECH-4A must be submitted Economizer Thermostat Fan Control Date 4/23/2010 Climate Zone Total Cond. Floor Area Addition Floor Area 7 6,854 n/a D High-Rise Residential D Hotel/Motel Guest Room Bldg. m Conditioned Spaces D ^Sf"*8**** D Addition D Alteration 0 °^JEnvelopeTDV 0 Unconditioned (file affidavit) 180 deg Inspection Criteria OFFICES HP-UNIT Packaged DX 1 40,500 Btu/hr 8.00HSPF 41, 000 Btu/hr 14.5 SEER/ 12.0 EER R-8.0 No No Economizer Setback Required Constant Volume Inspection Criteria SHOWROOM HP-UNITS Packaged DX 2 60,000 Btu/hr 8.00 HSPF 59,000 Btu/hr 14.2 SEER/ 12.0 EER R-8.0 No No Economizer Setback Required Constant Volume FIELD INSPECTION ENERGY CHECKLIST Meets Criteria or Requirements Special Feature1 n D a n n n a n n n D D Pas*. n .0..- •&•• P - ET, , a •fl a .D &;, o. , a : FSrf . ,'C[ J? -B , E „ 5• a . "&•- -ts • a -D , •&- •, 0 FIELD INSPECTION ENERGY CHECKLIST Special Feature1 D D D D n n n n n n n n Pas*; , ~m > o- •-, a Q^# 'j o •: &,' Ofr^ . cr "<• '&< ; ; 13- • P -"m* ^a ' , iff • / {fel,, » • . '-a. '. ,r^.^^$?' •v W • -r^-.-%&', "a- -•"m D 1 . Indicate special feature DETAILS on Page 2 of the Inspection Checklist Form. 2. If the Actual installed equipment performance efficiency and capacity is less than the Proposed (from the energy compliance submittal or from the building plans) the responsible party shall resubmit energy compl ance to include the new changes. 3. For additional detailed discrepancy use Page 2 of the Inspection Checklist Form. 4. Indicate Equipment Type: Gas (Pkg or, Split), VAV, HP (Pkg or split), Hydronic, PTAC, or other. EnergyPro 5.0 by EnergySoft User Number: 7231 RunCode: 2010-04-23710:06:52 ID: 10.38.00 Page 11 of 21 CERTIFICATE OF COMPLIANCE and (Part 1 of 4) MECH-1 C FIELD INSPECTION ENERGY CHECKLIST Project Name FLOORING AMERICA By Picket Fence Design Project Address 271 8 GATEWAY ROAD CARLSBAD GENERAL INFORMATION Building Type: ° Nonresidential Date 4/23/2010 Climate Zone Total Cond. Floor Area Addition Floor Area 7 6,854 n/a D High-Rise Residential D Hotel/Motel Guest Room D Schools (Public School) D Relocatable Public School Bldg. El Conditioned Spaces D (affidavit)'0"601 SpaCSS Phase of Construction: D New Constructbn Approach of Compliance: D Component Front Orientation: N, E, S, W or in Degrees: HVAC SYSTEM DETAILS Equipment2 Item or System Tags (i.e.AC-1,RTU-1,HP-1) Equipment Type4: Number of Systems Max Allowed Heating Capacity Minimum Heating Efficiency Max Allowed Cooling Capacity Cooling Efficiency Duct Location/ R-Value Duct Leakage Testing - If Yes, a MECH-4A must be submitted Economizer Thermostat Fan Control Equipment2 Item or System Tags (i.e.AC-1,RTU-1, HP-1) Equipment Type4: Number of Systems Max Allowed Heating Capacity Minimum Heating Efficiency Max Allowed Cooling Capacity Cooling Efficiency Duct Location/ R-Value Duct Leakage Testing - If Yes, a MECH-4A must be submitted Economizer Thermostat Fan Control D Addition D Alteration 0 °^JEnvelopeTDV D Unconditioned (file affidavit) 180 deg | Inspection Criteria SHOWROOIWWHOUSE HP-UNITS Packaged DX 2 45,500 Btu/hr 8.00HSPF 46,000 Btu/hr 14.5 SEER /1 2.0 EER R-8.0 No No Economizer Setback Required Constant Volume Inspection Criteria SERVER RM AC-UNITS Split DX 1 0 Btu/hr n/a 12,300 Btu/hr 13.5 SEER/ 10.0 EER R-8.0 No No Economizer Seftbac/c Required Constant Volume FIELD INSPECTION ENERGY CHECKLIST Meets Criteria or Requirements Special Feature1 D D D D a n D n D n D D 'Pas'sr-- m #-,* Q," Q,'"" . M \ 0 •p. , P C3 D ,P '. t| -.-. Wf3 '"d '.M ' ',P '"•£' ' f,v:-a- . •4"13 • : .ci ' "0 n a ' M . , '-'D FIELD INSPECTION ENERGY CHECKLIST Special Feature1 D G HI n n n D n n n n n '!&& ;-' D ' ! ad ; • fe.# dc ''1?%'1I u r -: P':J Q' ij! & * a '-. a m3 Q Q" JO i-^f\*'*6i .' it -Wft- ! r?is,-ir**ftvv „ - "^Y/f^-f fr ' '*$, '. ' ,r;fr •rvQ,-, •Q ' 1. Indicate special feature DETAILS on Page 2 of the Inspection Checklist Form. 2. If the Actual installed equipment performance efficiency and capacity is less than the Proposed (from the energy compliance submittal or from the building plans) the responsible party shall resubmit energy compliance to include the new changes. 3. For additional detailed discrepancy use Page 2 of the Inspection Checklist Form. 4. Indicate Equipment Type: Gas (Pkg or, Split), VAV, HP (Pkg or split), Hydronic, PTAC, or other. EnergyProS.ObyEnergySan User Number: 7231 RunCode: 2010-04-23T1 0:06:52 ID: 10.38.00 Page 12 of 21 Project Name FLOORING AMERICA By Picket Fence Design Date 4/23/2010 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 2 of 4)MECH-1C SPECIAL FEATURES INSPECTION CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Discrepancies: EnergyPro 5.0 by EnergySoft User Number: 7231 RunCode: 2010-04-23T10:06:52 ID: 10.38.00 Page 13 of21 EnePro 5.0 by ESofin n | aos o N §FUJITSU ASU12&AOU?• 8<;•H It <?> k *8 n n n n n n n n n El El n n n n n n D B El H n n n n n n n n n n n n D D n n n a D D n n n n n a a n D D n n n n n n n n n n D n n n D n n D n n D n n n n n n n n n n n n n n n n n n D n n n n n n 5g~^•IX M a a n n n n D n OutdoorVentilationForVAV & CAVAirDistributiDuctsm >B tl. li1 $H «-*(Q <J) :8fl i- o M|ii°-i» Sllil" S: I S" 5? § ||^I| w Si ""5.5 iil 8BT o g- a-- S S" *s>o ge 3- rrSf —I Q. 3 ?n ®^g S-cr Q. " g^. (D 5" • llg-« |i ® ^. ID ^^ °8° 3ID w a> (p ° 5£ ° 3sisS r M ' iff — 2— * 5 .oca S Hal f|jo on » o S^.7" 3 o » <2.j2 (PCOS J *7K" «" Ji? e~ ^ O m S 5- °- S' in (D I > (D CO 0) C7 2 2 03 tn3 3 = (D•a w Q Q- IH|^i-«lsO 2m ®-*> 5 Q.s^aSO) C „, ,=• i|l5F*"^ f !!II o § o i1-^^s = 3 ^ f S8nj tfj to (D-'*~t w=cn' 11" CL to" fl) 51 2.CO ?!O| CD i»I 2 Do 5 CD I<D 8 f om3 Tl O 3m O•n OO 0m Q. m o •om O mzm 30 O O mO7s -DQJ o o mO i_io m 'ergyPro 5.0 by EneriSa s I 1 f3 —a. ai \unCode: 201 C? ao opi S3 B 3 bo 1 Cn Siho n n n n n n n n n n n n n n n n n n n n n n D n D D n n n n n n n n n n n n n D n n n n n a a n a n n n n a n n a n n a a n a n a a a n a a a a a a D a a a a a n a a D n n n n n n a n a a a a a a a n 3 tnovszmsv nsj.itM "* a a a n 0?Tier 50VT-A48— 50to a a n D ?rier 50VT-A60— 50N) D D D D s?rier 50VT-A42— 50~* n D n D Equipment Reqii_ n—i z.1 o ' S'g D O<§ m Tl cm 5"&3 ?• 3 5T W fio Sc)> ^<| s| N I. &- 1- 3 co ~n <P _ QO fil« 5 DistributedEnergy StoraDXACSystems<Q<D wg! «° 5 S'g a. "mo^2<3 8 TD 1s.s? DmCOo 3j o 1 > 1 u 1 mo i» S 5 )ject NameOORING AMEi<S. Q CD 3 "•y. ? § D f o 1o O ERTIFICATm 0 Tl O Os c zom D a. •n m D z •o ECTIONm 2m 33O-< O mO ^S CO-1 IDQ) j^ a ^ m0 i ••L O AIR SYSTEM REQUIREMENTS (Part 1 of 2) MECH-2C Project Name Date FLOORING AMERICA By Picket Fence Design 4/23/2010 Item or System Tags (i.e.AC-1,RTU-1,HP-1) Number of Systems MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat and Cool Air Supply Reset Electric Resistance Heating1 Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted Indicate Air Systems Type (Central, Single Zone, Packag ' 'OFFICES HP-UNIT 1 SHOWROOM HP-UNITS 2 e, VAV, or etc...) OWROOMM/HOUSE HP-UNI 2 Indicate Page Reference on Plans or Schedule and indicate the applicable exception^) T-24 Sections 112(a) 112(a) 112(b), 112(c) 112(c), 115(a) 12 1(b) 12 1(b) 12 1(c) 121(c) 122(8) 122(e) 122(f) 122(g) 123 124 8.00 HSPF 14.5 SEER/ 12.0 EER Yes n/a yes 166 cfm No No Programmable Switch Setback Required Auto n/a R-8.0 8.00 HSPF 14.2SEER/12.0EER Yes n/a yes 365 cfm No No Programmable Switch Setback Required Auto n/a R-8.0 8.00 HSPF 14.5SEER/12.0EER Yes n/a Yes 244 cfm No No Programmable Switch Setback Required Auto n/a R-8.0 144(a & b) 144(a&b) 144(a & b) 144(a & b) 144(c) 144(c) 144(c) 144(d) 144(e) 144(f) 144(g) 144(i) 144(k) n/a 30,982 BWhr n/a 30,105 Btu/hr Constant Volume Yes No No Economizer Constant Temp Constant Temp No n/a 91, 799 Btu/hr n/a 88,120 Btu/hr Constant Volume Yes No No Economizer Constant Temp Constant Temp No n/a 69,614 Btu/hr n/a 67,032 BWhr Constant Volume Yes No No Economizer Constant Temp Constant Temp No 1 . Total installed capacity (MBtu/hr) of all electric heat on this project exclusive of electric auxiliary heat for heat pumps. If electric heat is used explain which exception(s) to §144(g) apply. EnergyPro 5.0 by EnergySoft User Number: 7231 RunCode: 2010-04-23710:06:5 ID: 10.38.00 Page 16 of 21 AIR SYSTEM REQUIREMENTS (Part 1 of 2) MECH-2C Project Name Date FLOORING AMERICA By Picket Fence Design 4/23/2010 item or System Tags (U.AC-1,RTU-1,HP-1) Number of Systems MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thermostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Insulation PRESCRIPTIVE MEASURES Calculated Design Heating Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat and Cool Air Supply Reset Electric Resistance Heating1 Air Cooled Chiller Limitation Duct Leakage Sealing. If Yes, a MECH-4-A must be submitted Indicate Air Systems Type (Central, Single Zone, Packag SERVER RM AC-UNITS 1 e, VAV, or etc...) Indicate Page Reference on Plans or Schedule and indicate the applicable exception(s) T-24 Sections 112(a) 112(a) 11203), 112(c) 112(c), 115(a) 121(b) 12 1(b) 121(c) 121(c) 122(e) 122(e) 122(f) 122(g) 123 124 n/a 13.5 SEER/ 10. OEER n/a n/a Yes 9cfm No No Programmable Switch Setback Required Auto n/a R-8.0 144(a & b) 144(a & b) 144(a & b) 144(a & b) 144(c) 144(c) 144(c) 144(d) 144(e) 144(f) 144(g) 144(i) 144(k) n/a OBtu/hr n/a 12,226 Btu/hr Constant Volume Yes No No Economizer Constant Temp Constant Temp No 1 . Total installed capacity (MBtu/hr) of all electric heat on this project exclusive of electric auxiliary heat for heat pumps. If electric heat is used explain which exception(s) to §144(g) apply. EnergyPro 5.0 by EnergySaft User Number: 7231 RunCode: 201 0-04-23T1 0:06:5 ID: 10.38.00 Page 17 of 21 I ErtergyPro 5.0 by EnergySott User Number: 72313 2 % g O (oao a^5 S Q UsOo§ -o 1Q i 1 12 z Transfer Air must be provid*equal to the difference betv3d where the Requiredreen the Required Venl= < o' ik3 — ~" 3 li || ? en" 3> <Q ffl Si 5"? it C ® 3 0 Z<° c" 3"3 3 3 ^S3 o'.Z i ? || c L,(n g S|" i H£. i Itn ^e. 3 2. i" <a 1i^ o S This must be less than or ec]ual to Column L and gireater thiS o i s(D (AC O^ Ooc 1 X s. z 1-1 Maximum of Columns H, J,K, or 300 CFM-Condition area (ft2) x 0.4 CFS 0 c_Design fan supply CFM (FaiOTl Xen o (D Q.IDw_ 3s3ID O e. 3isID Ua; C09 M -Must be greater than or equal to H, or use Transferjfe o"o_ =1 3 Z 3 3 o>cD Oa. 1 ence.X Required Ventilation Air (REIOC V.A.) is the largeroI £ Io Ii.Q 1CL § § 33 ?cocoo~*OOocTJ z O pCD co (^ c" | 0 0 9 m Based on fixed seat or the c0) X I number i3. | 1 §CL Oi O ioso 1 o"ft)5. o* CD CO en £3o <Dtn 31 en \1/1 =: o 1 CD!3 P" o Minimum ventilation ratepei—1 CO o"3 i<D 1 1tn Ooc33 ^S.o«. 3 <D i O*3 2> •| SERVER RM AC-UNITS \51 £ to (0 ISERI/ERROOM |0) S <o 1C <£>| SHOIVROOMAVHOL/SEHP-L/W/]S01 CO i4 NJ t \SHOWROOM/WAREHOUSE \^ 2 ^ ssi4 l\3t <0 | SHOWROOM HP-UNITS \51 £ Ol IV) Coa 1 ooS .to S oi Ol Ol IV) Cog 0)| OFFICES HP-UNIT \SSL S ^ §\OFFICESAREA \— i.§ p oi o> s0> ^^§| Zone/Systemo "i •42 ^5 X>0O <D Tlffi S TJ 2 o O3 ff 8" TJ g- S O g -Fi os<rSQ p) < msl^§ <£ O v^ 3- CDTl £ — «. o" 3 3 0 O c <5' QT1T3 3 JS31^^ rsi o•< o - (D Tl ^ -~. O 'Ej*' f" " TJJ5-3 0 £" en "** CO S§.>!:<? 1 " 1 "=' H ? ' DO O D m •n O I c_ X "~ s Z AREA BASIS08io n % 0) < § Z cS MECHANICAL VEN1 oz KS S 3D m H iH o ^ _kgi(Project NameFLOORING AMERICA By PicketD o ^ t w^\ o o I MECHANICAL VENTILA-i 0 ZD m Xm^> H m CO 0 r m Olb *«: I Z u ! <B ao B 3 8 Q(D <O O 3 D D D D D D | FUJITSU ASU1 2&AOU12Constant VolumeNo Economizer1 -5 D 3> D | Carrier 5QVT-A48—50Constant VolumeNo EconomizerOJ8 p D a a | Carrier 50VT-A60--50Constant VolumeNo Economizer"o8 P a (D a \Carrier50VT-A42-~ 50Constant VolumeNo Economizer8 p a CD a I System Namei1 Economizer Typeo•n to •a S3 II oTl DO TJ Premium 1Eff. MotorSUPPLY FANRETURN FAN |I CENTRAL SYSTEM FAN SUMMARY |\FUJITSU ASU12&AOU12•o1 1 - ob 1 1 13.5 SEER/ 10.0 EERr | Carrier 50VT-A48—50Packaged DX \ro Ol8 ob 8.00 HSPFo8 1 4.5 SEER/ 12.0 EERi\Carrier50VT-A60-50Packaged DX \to §o8 ob 00 8 1 Ol o8 14.2 SEER/ 12.0 EERf \Carrier50VT-A42-50Packaged DX \- .0 ob 00 8 1 |14. 5 SEER/ 12.0 EER! a> o ' D I | i Efficiencyo Efficiency1V)HEATINGCOOLINGI CENTRAL SYSTEM RATINGSa a a f os T3 'In PlenumOutsidei Add </?" Insulation II Hot Water PumpHot Water Piping Length (ft) |I MULTI-FAMILY CENTRAL WATER HEATING DETAILS |I o DistributionD 3Du I 3 !<Energy Factoror REStandby Lossor Pilot(A (A | DHW /BOILER SUMMARY |D D D I Equipment NameH O Efficiencyi1 at O O i CO TJ PremiumEff. Motor||PUMPS 1I CHILLER AND TOWER SUMMARY |1Project NameFLOORING AMERICA By Picket Fence DesignDate 14/23/2010 \I MECHANICAL EQUIPMENT DETAILS (Part 1 of 2) MECH-5C | Project Name FLOORING AMERICA By Picket Fence Design Date 4/23/2070 ENVELOPE MANDATORY MEASURES: NONRESIDENTIAL ENV-MM DESCRIPTION Building Envelope Measures: §118(a):Installed insulating material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20 Chapter 4, Article 3. §118(c):All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. §118(f):The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R-value of no less than R-13 between framing members. §117(a):All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. Manufactured fenestration products and exterior doors shall have air infiltration rates not exceeding 0.3 cfm/ft.2 of §116(a) 1: window area, 0.3 cfm/ft.2 of door area for residential doors, 0.3 cfm/ft.2 of door area for nonresidential single doors (swinging and sliding), and 1.0 cfm/ft.2for nonresidential double doors (swinging). §116(a) 2: Fenestration U-factor shall be rated in accordance with NFRC 100, or the applicable default U-factor. §116(a)3:Fenestration SHGC shall be rated in accordance with NFRC 200, or NFRC 100 for site-built fenestration, or the applicable default SHGC. §116(b):Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). EneravPro 5.0 by EneravSaft User Number: 7231 RunCode: 2010-04-23710:06:52 ID: 10.38.00 Page 20 of 21 Project Name FLOORING AMERICA By Picket Fence Design Date 4/23/2010 MECHANICAL MANDATORY MEASURES: NONRESIDENTIAL MECH-MM Equipment and System Efficiencies §111:Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. §115(a): Fan type central furnaces shall not have a pilot light. §123:Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. §124:Air handling duct systems shall be installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of the CMC Standards. Controls §122(e): Each space conditioning system shall be installed with one of the following: 1A. Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off-hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or 1B. An occupancy sensor to control the operating period of the system; or 1C. A 4-hour timer that can be manually operated to control the operating period of the system. 2.Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. §122(g): Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. §122(c):Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. §122(b):Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the §122(a&b): control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. Ventilation §121 (e):Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. §122(f):All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. Ventilation System Acceptance. Before an occupancy permit is granted for a newly constructed building or space, or a §121 (f): new ventilating system serving a building or space is operated for normal use, all ventilation systems serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance Service Water Heating Systems §113(c)Installation 3. Temperature controls for public lavatories. The controls shall limit the outlet Temperature to 110° F. 2.Circulating service water-heating systems shall have a control capable of automatically turning off the circulating pump when hot water is not required. EnergyPro 5.0 by EnergySoft User Number: 7231 RunCode: 2010-04-23T10:06:52 ID: 10.38.00 Page 21 of 21 RECORDING REQUESTED BY: Stewart Title of California. WHEN RECORDED MAIL TO AND MAIL TAX STATEMENTS TO: TK&C, LLC, a California limited liability company ORDER NO. 7034-285361 ESCROW NO. 7003-285361 APN. 213-263-15 I DOCtt 2010-0317937 JUN 24, 2010 8:00 AM OFFICIAL RECORDS SAN DIEGO COUNTY RECORDER'S OFFICE DAVID L BUTLER. COUNTY RECORDER FEES; 1013.55 OC: OC PAGES: GRANT DEED THE UNDERSIGNED GRANTOR(s) DECLARE(s): DOCUMENTARY TRANSFER TAX is: $ 1,001.55 CITY TAX Q Monument Preservation Fee is: ® computed on full value of property conveyed, or Q computed on full value less value of liens or encumbrances remaining at time of sale. Q Unincorporated area: H City of Carlsbad, and FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, LJR, LLC, a California limited liability company hereby GRANT(S) to TK&C PROPERTIES, LLC, a California limited liability company the following described real property in the, County of San Diego, State of California: See "Exhibit A" attached hereto 743.. DATE: June 18,2010 STATE OF CALIFORNIA COUNTY OF _SaA / LJR, LLC, a California limited liability company By: ^L.R. Frye, Managing Member On "21.before me, Public, personally appeared L B.. rV _a Notary , who proved to me on the basis of satisfactory evidence to be the persons, whose nameyr) is/ye subscribed to the within instrument and acknowledged to me tha<Jj^lfc/th/y executed the same ii^njs^'/thjeir authorized capacity(ips), and that by pgtaf/thdfr signatures on the iiEtrument the person^ or thjT entity upon behalfoTwnich we person^ acted, executed the instrument I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is true and correct^ WITNESS Signature v s/ , ^ — MAIL TAX STATEMENTS AS DIRECTED ABOVE JUUf CMOTEw (Seal) Description: San Diego,CA Document-Year.DocID 2010.317937 Page: 1 of 2 Order: 285361 Comment: I! s^ 5>, 5 & • -C o c D Q