Loading...
HomeMy WebLinkAbout2720 ABEDUL ST; ; 77-3024; PermitBUILDING PERMIT APPLICATION City of CARLSBAD, CALIFORNIA 92008 'pR 2"77 q~3204*****271'50 1 Clasrof work: ,obd ADDITION OALTERATION 0 REPAIR OMOVE REMOVE 0 Change of use from Change of use to NOTICE SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMB. ING. HEATING, VENTILATING OR AIR CONDITIONING, THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC- TION AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK ISSUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM- MENCED. ~~~ APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINE0 THIS ALL PROVISIONS OF LAWS AN0 ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT THE GRANTING OF A PERMIT DOES NOT CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. PRESUME TO GIVk AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING .IDATION CK. M.O. CASH Dwelling Units ZONING HEALTH DEPT. 4 I IIS SPACE) THIS IS YOUR PERMIT PERMIT VALIDATION CK. M.O. CASH INSPECTION RECORD USE SPACE BELOW FOR NOTES, FOLLOW-UP, ETC. 5-5-77 Fdn. forms, steel: O.K. Ed 5-13-77 Footings: O.K. R.S. Osburn 6-1-77 Sheathing: O.K. B. Nelson 6-2-77 Frame: O.K. B. Nelson 6-3-77 Insulation: Not- ready. B. Nelson 6-15-77 Drywall and Lath: O.K. B. Nelson I Class of work: 0 NEW 0 ADDITION 0 ALTERATION 0 REPAIR I Describe work: i I / 1: 1 - I - 'i - 4 - 5 f J - a - 9 - - I s - - - - - - I - - WHEN PROPERLY VALIDATED (IN THIS SPACE1 THIS IS YOUR PERMIT PLAN CHECK VALIDATION CK. M.O. CASU PERMIT VALIDATION CK. M.O. CASH NOTICF THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC- TION AUTHORIZED IS NOT COMMENCED WITHIN 1200AVS.OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM- . - - . . - - 11 SHOWER I KITCHEN SINK h DISP. q .i d I /I >'I /I DISHWASHER 1 LAUNDRY TRAY I /I>' I I_ CLOTHES WASHER f 2< / WATER HEATER J >" , URINAL I I 1 DRINKING FOUNTAIN FLOOR-SINKOR DRAIN I I SLOP51NK I I MENCED. APPLICATION AN0 KNOW THE SAME TO BE TRUE AND CORRECT. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. WASTE INTERCEPTOR NUMBER CLEANOUTS INSPECTOR 73-3dAerground Plbg. and Water: O.K. - B. Nelson 5-19-77 Underground Plbg and water: Needs test 6-2-77 Gas: O.K. B. Nelson 6-1-77 Rough: O.K. B. Nelson ... ,r PLAN CHECK VALIDATION oc LCD. urn PERMIT VALIDATION em. M.D. wn c NEW CO)(STRUCTION. FOR EACH -RES OF MAIN SERVICE, SWITCH, /#s FUSE OR BREAKER mnovfD 'On " '"' DlTt NEW SERVICE ON EXISTING BLffi. FOR EA. AMPERE OF INCREASE IN MAIN SERVICE, SWITCH, FUSE NOTICE MIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC- OR BREAKER CONSTRUCTIDN OR WORK ISSWIPENDED OR ABANDONED FOR A TION AUTHORIZE0 IS NOT COMMENCED WITHIN 120 DAYS.OR IF PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM. REMODEL, ALTERATION, NO CHANGE MENCED. IN SERVICE, FOR EA. MlPERE OF I HEREBY CERTIFY THAT I n VE READ AND EXAMINED THIS INCREASE APPLICATION AND KNOW THE &ME TO E TRUE AND CORRECT. ALL PROVlSKm OF UWS AND ORDINANCES QDVERNINQ THIS WPE of WORK WILL Dl! COMPLIED WITH WHETWER SPECIFIED PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REQULATINQ ING ZW AMP. HEREIN UR NOT THE QRANTINQ OF A PERMIT DOES NOT "TRUCTION OR THE PERFORMANCE OF CONSTRUCTION. MWME TO mvk AUTHORITY TO VIOLATE OR CANCEL THE TEMP. SERVICE Up To AND MAUD- SWIhWING Woc WIRIffi, INCREASE IN KRVICE 9 DacrMwork: ," PERMIT FEES SPECIAL CONDITIONS: No. I Typ ot Equi-nt I FN I Amcond. Units-H.P. E.. . It I I Rdrigumion Units-H.P. Ea. . I I NOTICE THIS PERMIT BECOMES NULL AN0 VOID IF WORK OR CONSTRUC- TION AUTHORIZED IS NOT COMMENCED WITHIN 11OOAYS.OR IF CONSTRUCTION OR WORK IS SUYENOEO OR ABANDONED FOR A I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS MENCEO. APPLICATION AN0 KNOW THE SAME TO (IE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES QOVERNINQ THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT THE QRANTINQ OF A PERMIT DOES NOT PRESUME TO QlVk AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REQULATINQ CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. PERIOD OF 1m DAYS AT ANY TIME AFTER WORK IS COM- I I I I I I .J ., PUN CHECK VALIDATION CK. M.O. M PERMIT VALIDATION CK. M.O. CAW . *5**.,. INSPECTOR REQUEST FOR INSPECTION TIMF f$ +i Permit No ._.. .................. ....... 9 i... > BUILDING I PLUMBING ELECTRICAL MISCELLANEOUS Insulation ................. .................................. 0 ................................ Drywall .................... .......................... 0 Pool Bonding .......... 0 Fdn. Forms .............. ............ 0 TempPole .............. 0 Steel ........................ ................ ................... 0 0 Sheathing 0 Underground 0 Lath .......................... .... 0 Ceil Heat .............. Frame ...................... ...................... .................... 0 ,Rough 0 ~sadv for Inspection - h.. TIM., wed., .~iru;S:l hi. ................ ...... .......... Final ........................ ........................ Efinal ...:. ................. Plenum & Ducts ....... 0 Porch ........................ 0 Patio ........................ 0 Driveway .................. 0 wall Sign 0 Fence ...................... Gading .................... 0 .......................... .......................... 0 Spscial Instructions Rpuested by phone numbw ........ Person Taking Fbport: .- REQUEST FOR INSPECTION TIME k%l. BUILDING I PLUMBING I ELECTRICAL MISCELLANEOUS _____~~ lnwlaion ................. 0 .................................. 0 ................................ 0 Sign .......................... 0 Underground .......... 0 undergrnd. mbg. ...... 0 hming ................ 0 Patio ........................ 0 Temp Pole .............. 0 Water Heater ............ 0 ~0. ana .............. 0 Plenum Dum ....... 0 ~.m .......................... 0 undargrnd.Water .... 0 Ceil bat .............. wall .......................... 0 Frame ...................... 0 Gading .................... 0 Final ...................... 0 Final ........................ 0 Final ....................... ...................... 0 Rough .................... 0 Fbugh ...................... 0 Drywall .................... Riveway 0 0 Sewer ................ 0 steel ........................ 0 Porch ........................ 0 Pool Bonding .......... 0 Gas .......................... 0 ................... .................. -for Inspection - Mm., TIM., Wed., Thus., Fri. Y\ Spscial Instructions ........ .. . - .. .~ n ,. .. c - >:b .,si, INTERDEPARTMENTAL INFORMATION SHEET BUTLDING DBPARTMENT I" DATE : BUILDING ADDRESS: 2 73(9&#f#& CITY OF: CARLSBAD ,, 7 /f I /I // 7 u' i '. /' -. I PLANNING DEPARTMENT ZONE &-/-~\BOLOT SIZE LOT WIDTH 90 I 1 UNITS PROVIDED / : UNITS ALLOWED i PARKING SPACES REQUIRED 2 PROVIDED ' X, COVERAGE ALLOWED PROVIDED '"LDING HEIGHT ALLOWED PROVIDED = EASEMENTS No #E "" FIRE PROTECTION EQUIP. OK TO FINAL 77-21s COR~~CTION LIST SINGLE FAMILY CITY OF CARLSBAD BUILDING DEPARTMENT AND MULTIPLE FAMILY RESIDENTIAL PL AN (714) 729-1181 *WARNING: PLAN CHECK FEES: Where no action is taken by the applicant in 120 days, and no building permit is issued, all plan Job Address: Owner Contractor: Engineer Occupancy Type of Construction Valuation Basic allowable bldg. area 1st Floor 2nd Floor 3rd Floor 4th Floor - Allowable Increase Due to REQUIRED PLANS 1. Plot Plan 6. Structural Details 2. Foundation Plan 3. Floor Plan 7. Elevation Plans 8. Roof Plan 4. General Framing 9. Index Sheet 5. Foundation Details TO THE APPLICANT A. Correct Plans where corrections has been circled. Flag Corrections. B. Incomplete, Indefinite or Faded Drawings or Calcu- lations not acceptable. C. Required Engineer's or Surveyor's Calculations or Plans shall be signed in ink. D. Reverse Plans may not be used. Provide correct Plot Plan, Foundation Plan, Floor Plan and Elevations. E. The approval of plans and specifications does not permit the violation of any section of the Building Code'or other City, County or State Law. GENERAL 1. Submit fully dimensioned Plot Plan, drawn to scale, including all easements on property. 2. Show all existing and proposed buildings on Plot Plan. 3. Show correct legal description on Plan. 4. Show all Off Site Improvements, Driveway Approach, Light Standards, Fire Hydrants, Water Meters, Sub 5. Correct Lot Dimensions. Structures, Trees, etc. '6. Show existing and finish contour lines. 7. Survey of Lot required. 8. Indicate all grading to be done. 9. Indicate Elevations of Garage Floor, and Street and Driveway. 10. Indicate Centerline and Edge Profile of Driveway. 11. Slope of driveway not to exceed 15%. 12. Indicate flow lines for disposal of surface water. 13. La Costa approval required. 13aSan Diego County Health Dept. approval required. 13bShow all requirements for handicapped. U.B.C. 13cL.C.W.D. sewer receipt required. 13dCoastal approval letter required. 14. Carry water from Section 1711. under sidewalk through curb into street with cast iron pipe. 15. Provide engineering calculations for QProvide engineer's moisture report. 17. Grading permit required. 18. Fire Dept. approval required. 19. Specify concrete mix @ 2000 PSI. minimum. 20. Dimension footing sizes and clearance from grade. 21. Show depth of footings below natural or undisturbed 22. Indicate pressure treated foundation still, or equal. 23. Show foundation bolt size, spacing and penetration grade. into concrete. %" x 17" for masonry. 24. Indicate clearance from grade to bottom of floor joists 25. Show pier size, spacing and depth, into undisturbed , soil. 26. Show girder size, spacing and direction. 27. Show all conditions of soils report on plans. 28. Show positive drainage away from footings on site 29. Specify minimum 18" x 24" access opening. 30. Where expansive soils exist, planters adjacent to found- 31. Specify underfloor ventilation equal to 2 square feet for each 25 lineal feet of foundation plus one opening within 3' of each corner. and girders. plan. 5" fall in 6 feet. , ations are not recommended. 32. Step footings when slope exceeds 1: 10. FRAMING 33. Provide typical framing details. 34. Specify all lumber grades. 35. Specify fire blocking at floor, ceiling cove and mid- 36. Show diagonal bracing at each corner and every 25 37. Clarify bracing of wall. 38. Show size, direction and spacing of floor joists in 39. Double floor joists or 40. Specify header size for openings over 4'. Show double 41. Insufficient beam size at 42. Provide rafter ties where ceiling joists and rafters are not parallel. 4' O.C. 43. Indicate rafter size, span, spacing and direction. 44. Show purlins on edge and indicate size. Same size as 45. Brace roof framing to partitions. 46. Indicate solid sheathing and 2 x 6 or 3 x 4 studs on 47. Show section through 48. Show planter box details and water proofing, Sec. 51. Provide typical chimney details. 52. Specify 2" minimum clearance between chimney and 53. Specify post protection when bearing on concrete. 54. Provide parapet details. 56. Specify inspection class 58. Provide drip screed 2" below mud sill. 59. Indicate how required structural and fire resistive integrity will be maintained. Where penetration will be made for electrical, mechanical, plumbing and communications conduits, pipes and similar systems. Section 301 D. height of walls over 10' in height. feet of wall. are overspanned. beam under parallel partitions. headers on edge. rafters minimum. first floor of three story construction. 2517 C7. framing. required for 60. Clarify dimensions at 61. Show window type, sizes and locations. 62. Light and/or ventilation inadequate in (1/10 floor area - 12 square feet min. except bath- room). ~ ~ 1“”” ~ ” . , 6a. Provide.vertical clearance and 64. Indicate attic scuttle (22” x 30” min.) horizontal clearance from range top to combustibles. 65. Provide draft separation for attic area in excess of 2500 sq. ft. 66. Separate area between dropped ceiling and floor above to 1000 sq. ft. max. 67. Specify stall shower min. width 30” minimum floor area 900 sq. inches. 68. Specify wall finish in shower area not to be adversely affected by moisture to 6’ above the floor, and provide shatterproof doors. 69. Water closet area minimum width to be 30”. 70. Show material to be used under tile. 71. Openings closer than 72. Show ceiling height. 73. Show lateral cross bracing at garage plate line. 74. Show bedroom window as exit, section 1304. to property line shall be of hour construction. ELEVATIONS 75. Indicate attic ventilation per section 3205 (c). 76. Show all eave overhangs and construction details. 77. Dimension chimney height above roof. (2’0’’ above 78. Indicate finish and natural grade to property line. 79. Show exterior wall finishes. 80. Indicate 15# felt or equal on exterior walls. roof withing 10’0’’). ROOF 81. Note roof pitch. 82. Indicate roofing material length & weather exposure 83. Show type, size and spacing of roof sheathing. 84. Fire retardant roof required due to location in on wood shingles. fire zone. GARAGES 86. Garages not permitted to open into sleeping room. 87. Provide separation on all walls and ceilings adjacent to living quarters. n 77-21 s 110. Indicate material to be used and location of sewer line. (If V.C.P. use flexible compression joints only.) 11 1. Show two way clean out in yard box with 5’ of build- ing. ELECTRICAL 112. Provide minimum 100 Amp. service. Condos require 113. Show meter and panel location. 113aShow fire warnings systems centered over stairs. 100 Amp. panel for each unit. Section 1310. MECHANICAL 114. Indicate furnace size, locations & registers and return air. (Size) 115. Indicate heating equipment in accordance with chapter 7 of Uniform Housing Code. 116. Specify heating, air conclitioning and ventilating equipment. Installations to comply with the uniform mechanical code. A. Access B. Location G. Ladder & Light C. Combustion Air H. Engineer’s D. Venting Calcs for E. Return Air Roof Loads 117. Indicate location & type of fire dampers. F. Ducts ELECTRIC 1975 N.E.C. 1. Ground-fault protection required for outdoor and 2. At least one receptical shall be installed outdoors bathroom receptacles 210-8. and gxages. 210-25b as shown on floor plan. required. Show on plans. v 1. Bored holes and notching, show details as per Section 2518, (F), 10, 11. 88. Specify .from garagelcarport into inimum height. 36” 9“ O.C. or equivalent 97. Indicate 6’ 6“ minimum headroom clearance above 98. Show stairway construction details. for open type balcony stairway. 100. Occupant load require-exits 101. Provide lights over stairways and public corridors. 102. Show change in floor level at doors 1” max. Sec. 3303h. 102aShow handrail extending 6” beyond the top & bottom risers & terminating in a post or safety terminal Sec. 3305 (i). from PLUMBING 103. Indicate location of water heater. 104. Show temperature and pressure relief valves on water heaters with discharge lines to outside. Sec. 1007. 105. Water heater not to be located in bathroom or under stairway or landing. 106. Providbsquare inches of ventilation at top and bottom of water heater. 107. Show water heater on 18 inch platform. 108. Provide water pressure regulator. Section 1007 (B). areas of the following: Porches Balconies Glass2 4% A. Show 6” insulation in ceiling. (R-19) B. Show 1 x block for insulation stop at vents. C. Show 4” insulation in walls (R-11) D. Show exterior doors weatherstriped. E. Place the following note on plans: 3. Insulation requirements: These plans comply with the requirements of the California noise insulation standards. SIGNED DATE TITLE F. Show details of party wall and floor system and S.T.C. or I.C.C. rating of each. 4. Have designer sign and date plans. CHECKED (DATE) RECHECKED (DATE) THE FOREGOING CORRECTIONS HAVE BEEN MADE AND ARE UNDERSTOOD BY THE UNDERSIGNED: OWNER - OR HIS AUTHORIZED AGENT ALPHA LABORATORIES, INC. SOIL&FOUNDATION ENGINEERING April 27, 1977 PROJECT NO: 0756 Gerrard and Wagner Builders 3751 Park Drive Carlsbad, California Attention: Mr. Jim Gerrard Gen t 1 enen : On April 25, !9?7, we sampled the soii on Lgt Nm 444, Meadcws I!o. 2, La Costa for the purpose of determining the nloisture content to a depth of 24". Our findings are. as follows: 1. Optimum Moisture for Soil Type Encountered 12.4% 2. Average Moisture in Building Area 23.7% If you have any questions, please do not hesitate to contact this office. This opportunity to be of service is sincerely appreciated. Respectfully submitted, ALPHG LABORATORIES, INC C. H.. Wood, RCE !OJ78 CHW:bi cc: (3) Submitted 7895 Convoy Court - Sen Diego . California 921'11 - 714/292-0660 LEUCADIA COUNTY WATER DISTRICT msr OFFICE BOX 2387 LEUCADIA. CALIFORNIA ~2024. 7.3.01~a June 10, 1977 Gerrard & Wagner Cons.truction 3751 Park Drive Carlsbad, Ca. 92008 . .IC 0 P Y.1 Dear Applicant: .. adopted Resolution No. 542 which provided for the expiration of sewer permits after 30 days if a building permit had not been obtained. .. On March 24, 1977 the Board of Directors of Leucadia County Water District Therefore, your sewer permit No. a dated located at 2720 Abedu St.. Ca bad has "- expire and for the property permit is hereby cancc ioL,'Sfee will be refunded to you at the Board meeting to be held on . If it is your intention to pursue a building permit for thi.s property you may reapply for a sewer service permit at the District office. At that time it will be necessary for you to pay the applicable connection fee. If you have any questions regardi,ng this mtter please contact me. yours very truly, LEUCADIA COUNTY WATER DISTRICT cc : City of Carlsbad RECEIVED JUN 14 1977 CITY OF CARLSBAD tuilding Dopariment Joan R. Geiselhart DISTRICT OFFICE: IS60 LA COSTA AVENUE * CARLSBACS CALIFORNIA .. .