HomeMy WebLinkAbout2722 LA GRAN VIA; ; CB091107; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 09-16-2009 Electrical Permit Permit No: CB091107 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Reference #: PC#: Project Title: Applicant: 2722 LA GRAN VIA CBAD ELEC 2162204300 ROSS RES-INSTALL ROOF MOUNTED BIPV SYSTEM GREEN ENERGY SOLUTIONS INC STE E 2131 LAS PALMAS DR 92011 888 749 7663 Electric Issue Fee Single Phase per AMP Three Phase per AMP Three Phase 480 Per AMP Remodel/Alteration per AMP Remodel Fee Temporary Service Fee Test Meter Fee Other Electrical Fees Additional Fees TOTAL PERMIT FEES Status: Lot#: 0 Applied: 0 0 0 0 Entered By: Plan Approved: Issued: Inspect Area: Owner: FRANK ROSS H&CHIANG G CARINA 2722 LA GRAN VIA CARLSBAD CA 92009 ISSUED 07/02/2009 LSM 09/16/2009 09/16/2009 $10.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $110.00 $0.00 $120.00 Total Fees: $120.00 Total Payments To Date: $120.00 Balance Due: Inspector: f'tl. ~ Clearance: $0.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions.· You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any I x i n f whi h v r i I OTI E imi h' whi h h f I' i i n h h i 4; <<11» Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717 / 2718 / 2719 Plan Check No. (!_8 ~ CITY OP Est. Value CARLSBAD Fax: 760-602-8558 www.carlsbadca.gov Plan Ck. Deposit Date JOBADN1ESS SUITE#/SPACE#/UNIT# APN CT/;>ROJE°i::T # LOT# # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE DCC. GROUP IP EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) AIR CONDITIONING FIRE SPRINKLERS YES O NO □ YES D NO □ CONT ACT HAME (If Different Fom Applicant) APPLICANT NAM ADOREf5 ADDRESS CITY STATE ZIP CITY STATE ZIP PHONE FAX PHONE FAX EMAIL EMAIL PROPERT 'f OWNER NAME CONTRACTOR BUS. NAME G~ ADDRESS J.{Z,,1 STATE ZIP C,4--7'2-Dt/ PHONE ',~ ->? -t z.,;-3 EMAIL ARCH/DESIGNER NAME & ADDRESS STATE UC.# Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of consent to sell-Insure lor workers' compensation as provided by Section 3700 of the Labor Code, for the performance ol the work for which lhis permit is issued. D I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permtt is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. Policy No. _______________ Expiration Date __________ _ !h" sectio;1 need not be completed ii the permtt is for one hundred dollars ($100) or less. Certif'.cate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of 1omia. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and clvll fines up to one hundred thousand dollars (&100,000), In ad<I1tion to ~he cost of compensation damages as provided lo in Section 3706 of the Labor code, Interest and attorney's fees. 2$ CONTRACTOR SIGNATURE _ ,• ,.,,,~ DATE 7-:2_ -0 I hereby atlirm that I am exempt from Contractor's License Law for the following reason: □ I, as owner ol lhe property or my employees wilh wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. 11, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). □ I, as ,wmer of the property, am exclusively contracling with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does nol apply to an owner of prop1rty who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). □ l ar1 exempt under Section, _____ Business and Professions Code for fhis reason: 1. i personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No ~ 1 (have/ have not) signed an application for a building pennil for the proposed work. ~'-. I have contracted with the following person (!inn) 10 provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the rollowing person lo coordinate, supervise and provide the major work (include name/ address I phone/ contractors' license number): s. , will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated {include name/ address/ phone/ type of work): 2$ PRC•PERTY OWNER SIGNATURE DATE ' Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required !o obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school srte? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES ANO THE AIR POLLUTION CONTROL DISTRICT. I certify that I have read the application and state that the above Information ls correct and that the infonnation on the plans Is accurate. I agree to comply with all City ordinances and State laws relating to building construction. 1 hereby authcirize representabve of the City of Carlsbad to enter upoo the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST Al.,. LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An m:HA permrt is required for excavations over 5'0' deep and demolition or construction of stn;ctures over 3 stories in height. EXPIRATION. ~:very pem,it issued by the Building Offteial under the provisions this Cooe shall expire by limitation and become null and void d the building or work authorized by such pem,rt is not commenced within 180 days from Irie date of such pennlt or W ilding or work authorized bys rmrt is suspended or abandoned at any time after the WOO<. is commenced for a period of 180 days (Section 106.4.4 Uniform Buikfing Cooe). 25 APPI.ICANrs SIGNATURE DATE ?-2-0 @ . . City of Carlsbad Bldg Inspection Request . . . Permit# CB091107 For 10/05/2009 Title ROSS RES-INSTALL ROOF Description MOUNTED BIPV SYSTEM Type ELEC Sub Type: Job Address: 2722 LA GRAN VIA Suite: Lot 0 Location· APPLICANT GREEN ENERGY SOLUTIONS INC Owner FRANK ROSS H&CHIANG G CARINA Remarks: Total Time: CD Description Act Comment Inspector Assignment: JM --- Phone: 7608156234 Inspector: M l- Requested By: NA Entered By: CHRISTINE 39 Final Electrical a t"g.~(. -t?A-rn.. $/t 3' O':; 4-Mp~~ Ol~ .~ t V<l~!tLb/U,1-ulh> d 11-A~~ ~ ,.o l,l. .. -t"t> ~J--l ~ ~~ t , Comments/Notices/Holds Associated PCRs/CVs Original PC# Inspection History Date Description Act lnsp Comments 09/18/2009 34 Rough Electric CO JM NOTICE 09/17/2009 34 Rough Electric CO JM SEE RECORD CARD EsGil Corporation In <Partners6ip wit6 government for 1/Jui(tfing Safety DATE: 9/1/09 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 09-1107 PROJECT ADDRESS: 2722 La Gran Via SET: II PROJECT NAME: Chiang Roof Mounted PV System ~NT ~ D PLAN REVIEWER D FILE ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Mail Telephone Fax In Person 0 REMARKS: By: Eric Jensen EsGil Corporation □ GA □ EJ □ PC Enclosures: 08/27/2009 Fax#: 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 r EsGil Corporation In <Partnersfiip witli. qovernment for <Bui[tfing Safety DATE: 07/10/2009 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 09-1107 PROJECT ADDRESS: 2722 La Gran Via SET I PROJECT NAME: Chiang Roof Mounted PV System □ APPLICANT ~ □ PLAN REVIEWER □ FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [gl The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [g] The applicant's copy of the check list has been sent to: Green Energy Solutions 2131 Via Palmas Drive, Ste. E Carlsbad, CA 92011 e-mail: dave@patriotroofing.com D Esgil Corporation staff did not advise the applicant that the plan check has been completed. [g] Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Dave Telephone#: 858-353-1253 Date contacted:7 f I~/ cO, (py: ~ ) Fax #: 760-634-2499 '"· Mail <---'felephone ._.,. Fax In Person 0 REMARKS: By: Aaron Goodman EsGil Corporation D GA D EJ D PC Enclosures: 07/07/2009 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 ,. City of Carlsbad 09-1107 07'/10/2009 GENERAL PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2722 La Gran Via DATE PLAN RECEIVED BY ESGIL CORPORATION: 07/07/2009 REVIEWED BY: Aaron Goodman FOREWORD (PLEASE READ): PLAN CHECK NO.: 09-1107 DATE REVIEW COMPLETED: 07/10/2009 This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections and submit two new complete sets of prints to: ESGIL CORPORATION. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? □ Yes □ No r City of Carlsbad 09-1107 07/10/2009 [DO NOT PAY -THIS IS NOT AN INVOICE} VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: Aaron Goodman BUILDING ADDRESS: 2722 La Gran Via PLAN CHECK NO.: 09-1107 DATE: 07/10/2009 Set: I BUILDING OCCUPANCY: R-3 TYPE OF CONSTRUCTION: V-B BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code CB -----------"--·-. Bid . Permit Fee b Ordinance g y Plan Check Fee by Ordinance Type of Review; D Repetitive Fee i.., I Repeats • Based on hourly rate □ By Ordinance ; ... Complete Review D Other 0 Hourly EsGil Fee Comments: Roof Mounted PV System Reg. VALUE Mod. D Structural Only 1IHr.@* 1----$-8-6-.0---10 ~---~ ($) $107.501 $86.001 Sheet 1 of 1 macvalue.doc + r City of Carlsbad 09-1107 07/10/2009 1. Please make all corrections and submit two new complete sets of prints, to: Esgil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, (858) 560-1468. 2. All plan documents shall be legible including mfg. cut sheets, ICC evaluation report(s), single line drawing(s), etc. 3. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 4. Provide a statement on the Title Sheet of the plans, stating that this project shall comply with the 2007 California Building Code, which adopts the 2006 IBC, 2006 UMC. 2006 UPC and the 2005 NEC. 5. Provide a fully dimensioned site plan drawn to scale. Sec. A 106.1.1. Please include the following: a) North arrow. b) Streets/alleys. c) Property lines/easements (ground mounted systems only). d) Existing and proposed buildings and structures (ground mounted systems only). 6. Clearly dimension building setbacks from property lines, street centerlines, and from all adjacent buildings and structures on the site plan. Sec. A 106.1.1. 7. Explain in the "Scope of Work" and show in the plans all structures and equipment included with this project. Any portion of the project shown that is not that is not part of this project should be clearly identified as "not included." Sec. A106.1.1. 8. Provide the manufacturers specifications for the PV Module(s), lnverter(s), disconnect(s), gutter(s), and sub-panel(s) and any other system equipment proposed to be installed in this system. Sec. A 106.1.1. • GENERAL REQUIREMENTS 9. Show the location of all equipment, PV arrays, junction box(s), combiner box(s), disconnect(s), lnverter(s), panelboards and services. 10. Show how the conductors will be run from the array to the main panel. Call out the type of conductor/cable to be used. 11. Include on the single line diagram voltage, conductor description (number and sizing), overcurrent device sizing, grounding design, equipment layout, and service fuse description (size and layout). 12. Call out on the plans the number and size of all conductors from each output circuit or series connected panel, inverter input circuit and inverter output circuit to the main panel. Describe the wiring methods to be used. Be sure to show compliance with NEC Article 690.31 for approved cable types. City of Carlsbad 09-1107 07/10/2009 13. Show/call out the ampere rating of overcurrent devices in circuits supplying power to the main panel busbar. The sum of the ampere ratings of the overcurrent devices shall not exceed 120 percent of the rating of the busbar. Include all existing main service disconnect sizing to verify compliance with NEC 690.64. END OF REVIEW To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • Have changes been made to the plans not resulting from this correction list? Please indicate: Yes □ No □ The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Aaron Goodman at Esgil Corporation. Thank you PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB091107 DATE 7/2/09 ADDRESS 2722 LA GRAN VIA RESIDENTIAL ADDITION- MINOR (<17,000.00) RETAINING WALL VILLAGE FAIRE OTHER SOLAR PANELS POOUSPA TENANT IMPROVEMENT COMPLETE OFFICE BUILDING PLANNER GINA RUIZ ENGINEER'---------- DATE 7/6/09 DATE ______ _ Hc\ADMIN\ COUNTER/PLANNING/ENGINEERING APPROVAi.i